Laserfiche WebLink
�_ <br /> ., <br /> TRIf�11�TY I ERD <br /> TABLE 2A:STEEL oR CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TeaR-OFF)oR RECOVER <br /> SYSTEM TYPE B:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER <br /> System Deck Base Insulation Layer Top Insulation Layer Roof Cover/Adhesive MDP(psf) <br /> No. (See Note 1) Type Fastener Attach Type Attach <br /> VERSIWELD MEMBRANE APPUCATIONS($EE NOTE 17�: <br />� Min.22 ga.,type B, Min.1.5-inch Polyisocyanurate FAST 100,FAST 100 LV, <br /> 1 per 3.2 Min.0.25-inch SECUROCK VersiWeld/Aqua Base 120 BA, <br /> SC-1 Grade 33 steel or min. MP-H,H-Shield,SecurShield or H- See Note 2 ft= Gypsum-Fiber Roof Board Flexible FAST,BIAB VersiWeld BA or Low VOC BA �45.0* <br /> 2,500 psi conc. Shield CG (ribbon or full coverage) <br />' Min.22 ga.,type B, Min.0.5-inch Dens Deck followed 1 per 2.7 Flexible FAST(ribbon), VersiWeld/Aqua Base 120 BA or <br /> SC-2 Grade 33 steel or min. by min.2.0-inch Insulfoam VIII See Note 2 ftZ Min.1.5-inch Insulam(OSB) 6-inch o.c. VersiWeld BA -37.5* <br /> 2,500 psi conc. <br /> Min.22 ga.,type B, Min.0.5-inch Dens Deck followed 1 per 2.0 Min.2.0-inch Insulfoam HD Flexible FAST(ribbon), VersiWeld/VersiWeld BA or Low <br /> SC-3 Grede 33 steel or min. by min.2.0-inch Insulfoam VIII See Note 2 ft2 Composite 6-inch o.c. VOC BA -45.0* <br /> 2,500 psi conc. <br /> ��t�� ' Min.0.5-inch Dens Deck followed 1 per 2.0 FAST 100 LV(ribbon),6- VersiWeld/Aqua Base 120 BA or <br /> SC-4 Grade 33 steel or min. by min.3.0-inch Insulfoam VIII See Note 2 ftZ Min.1.5-inch Insulam(OSB) inch o.c. VersiWeld BA -75.0 <br /> 2,500 psi conc. <br /> Min.22 ga.,type B, Min.1.5-inch Polyisocyanurete Insultite with 1 per 1.78 Min.0.5-inch SecurShield HD _Flexible_EAS_T_(rib6on),-VersiWeld./_Low VOC-BA-or-Sure-- -- <br /> ---SC=S -Grade 33-steel-or min--N1P=H,-H=Shield,-SecurShield,-H--HPV lnsulation- <br /> 2,500 psi conc. Shield CG Fastening Plates ftZ or H-Shield HD 6-inch o.c. Seal 90-8-30A BA -52.5 <br /> Min.22 ga.,type B, Min.1.5-inch Polyisocyanurete Insultite with 1 per 1.33 Min.0.5-inch SecurShield HD Flexible FAST(ribbon), VersiWeld/Sure-Seal 90-830A <br /> SC-6 Grade 33 steel or min. MP-H,H-Shield,SecurShield,H- HPV insulation <br /> 2,500 psi conc. Shield CG Fastening Ptates ftZ or H-Shield HD 4-inch o.c. gq -75.0 <br /> Min.22 ga.,type B, Min.1.5-inch Polyisocyanurete Insultite with <br /> SC-7 Grade 33 steel or min. MP-H,H-Shield,SecurShield,H- HPV Insulation 1 per 1.33 Min.0.5-inch SecurShield HD Flexible FAST(ribbon), <br /> VersiWeld/Low VOC BA -82.5 <br /> 2,500 psi conc. Shield CG Fastening Plates ft2 or H-Shield HD 4-inch o.c. <br /> Min.1.5-inch ACFoam II, <br /> Min.22 ga.,type B, Polyisocyanurate MP-H,H- <br /> Min.0.5-inch Dens Deck or Dens 1 per 2.0 VersiWeld/Aqua Base 120 BA or <br /> SC-8 Grade 33 steel or min. Deck Prime See Note 2 ft� Shield,SecurShield,H-Shield OB500 VersiWeld BA -37.5" <br /> 2,500 psi conc. CG,ENRGY 3 followed by Min. <br /> 0.25-inch Dens Deck Prime <br /> Min.22 ga.,type B, Min.2-inch Polyisocyanurete MP- 1 per 4.0 Min 0.25-inch SECUROCK VersiWeld/Aqua Base 120 BA, <br /> SC-9 Grede 33 steel or min. H,H-Shield,SecurShield,H-Shield See Note 2 ftx Gypsum-Fiber Roof Board 0B5�� VersiWeld BA or Low VOC BA -37'SF <br /> 2,500 psi conc. CG <br /> Min.1.5-inch ACFoam II, <br /> Min.22 ga.,type B, polyisocyanurate MP-H,H-Shield, 1 per 2.0 Additional layers of base VersiWeld/Aqua Base 120 BA or <br /> SC-10 Grade 33 steel or min. SecurShield,H-Shield CG,ENRGY See Note 2 ftx insulation OB500 VersiWeld BA -45.0* <br /> 2,500 psi conc. 3 <br /> EMerior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6 <br /> Certificate of Authorization#9503 Revision 5:06/19/2014 <br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 6 of 36 <br />