<br /> TABLE 2A:STEEL OR CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)Ort RECOVER
<br /> SYSTEM TYPE B: MECHANICALLYATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
<br /> System Deck Base Insulation Layer Top Insulation Layer Roof Cover/Adhesive MDP(psf)
<br /> No. (See Note 1) Type Fastener Attach Type Attach
<br /> Min.1.5-inch ACFoam II,
<br /> Min.22 ga.,type B, polyisotyanurate MP-H,H-Shield, 1 per 2.0 Min.1.5-inch SecurShield HD VersiWeld/VersiWeld BA or Low
<br /> SC-il Grade 33 steel or min. SecurShield,H-Shield CG,ENRGY See Note 2 ftZ Composite,H-Shield HD OB500 VOC BA -45.0*
<br /> 2,500 psi conc. 3 Composite
<br /> Min.1.5-inch ACFoam II,
<br /> Min.22 ga.,type B, polyisocyanurate MP-H,H-Shield, 1 per 2.0 Min.0.25-inch Dens Deck, VersiWeld/Aqua Base 120 BA or
<br /> SC-12 Grade 33 steel or min. SecurShield,H-Shield CG,ENRGY See Note 2 ft� Dens Deck Prime OB500 VersiWeld BA -45.0*
<br /> 2,500 psi conc. 3
<br /> Min.1.5-inch ACFoam II,
<br /> Min.22 ga.,type B, Min.0.5-inch Dens Deck or Dens 1 per 2.0 Polyisocyanurate MP-H,H- ' VersiWeld/Aqua Base 120 BA or
<br /> SC-13 Grede 33 steel or min. See Note 2 � OB500 -45.0*
<br /> Deck Prime ft Shield,SecurShield,H-Shield VersiWeld BA
<br /> 2,500 psi conc. CG,ENRGY 3
<br /> Min.22 ga.,type B, Min.2.0-inc ACFoam II,
<br /> Polyisocyanurate MP-H,H-Shield, 1 per 4.0 Additional layers of base VersiWeld/Aqua Base 120 BA or
<br /> SC-14 Grade 33 steel or min. SecurShield,H-Shield CG,ENRGY See Note 2 ft2 insulation OB500 VersiWeld BA -45.0*
<br /> 2,500 psi conc. 3
<br /> Min.2.0-inch ACFoam II,
<br /> Min.22 ga.,type B, polyisocyanurate MP-H,H-Shield, 1 per 4.0 Min.1.5-inch SecurShield HD VersiWeld/VersiWeld BA or Low
<br /> SC-15 Grade 33 steel or min. SecurShield,H-Shield CG,ENRGY See Note 2 ft� Composite,H-Shield HD OB500 VOC BA -45.0*
<br /> 2,500 psi conc. 3 Composite �
<br /> Min.2.0-inch ACFoam II,
<br /> Min.22 ga.,type B, polyisocyanurate MP-H,H-Shield, 1 per 4.0 Min.0.25-inch Dens Deck, VersiWeld/Aqua Base 120 BA or
<br /> SC-16 Grade 33 steel or min. SecurShield,H-Shield CG,ENRGY See Note 2 ft� Dens Deck Prime OB500 VersiWeld BA -45.0'
<br /> 2,500 psi conc. 3
<br /> Min.22 ga.,type B, Min.1.5-inch Polyisocyanurate 1 per 3.2 Min.0.25-inch SECUROCK VersiWeld/Aqua Base 120 BA;
<br /> SC-17 Grede 33 steel or min. MP-H,H-Shield,SecurShield,H- See Note 2 ft� Gypsum-Fiber Roof Board OB500 VersiWeld BA or Low VOC BA -45.0*
<br /> 2,500 psi conc. Shield CG
<br /> Min.22 ga.,type B, Min.2-inch Polyisocyanurate MP- 1 per 2.67 Min 0.25-inch SECUROCK VersiWeld/Aqua Base 120 BA,
<br /> SC-18 Grade 33 steel or min. H,H-Shield,SecurShield,H-Shield See Note 2 ftx Gypsum-Fiber Roof Board OB500 VersiWeld BA or Low VOC BA -45.0*
<br /> 2,500 psi conc. CG
<br /> Min.22 ga.,type B, Min.2-inch Polyisocyanurate MP- 1 per 1.6 Min 0.25-inch SECUROCK VersiWeld/Aqua Base 120 BA,
<br /> SC-19 Grade 33 steel or min. H,H-Shield,SecurShield,H-Shield See Note 2 ft= Gypsum-Fiber Roof Board OB500 VersiWeld BA or Low VOC BA -60.0
<br /> 2,500 psi conc. CG
<br /> VERSIFLEECEMEMBRANEAPPLICATIONS�SEENOTEI7�: �
<br /> Min.22 ga.,type B, Min.0.5-inch Dens Deck followed 1 per 2.7 Flexible FAST(ribbon), VersiFleece/AquaBase 120 BA or
<br /> SC-20 Grede 33 steel or min. by min.2.0-inch Insulfoam VIII See Note 2 ft2 Min.1.5-inch Insulam(OSB) 6-inch o.c. FAST 100,FAST 100 LV,Flexible -37.5*
<br /> 2,500 psi conc. FAST
<br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6
<br /> Certificate of Authorization#9503 Revision 5:06/19/2014
<br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 36