Laserfiche WebLink
� TRINIIY,ERD <br /> TABLE 26:STEEL oa CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TenR-OFF)on RECOVER <br /> SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER <br /> Top Insulation Layer <br /> System Deck Base Insulation Layer , Roof Cover/Adhesive MDP(ps� <br /> No. (See Note 1) Type Fasteners Attach <br /> VERSIWELD MEMBRANE APPLICATIONS(SEE NOTE 17�: <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 7/16-inch APA orTECO reted OSB Trufast SIP LD 1 per 3.2 ftZ VersiWeld/Aqua Base 120 BA or 37.5* <br /> SC-36 Grade 33 steel layers,any combination,loose laid Fasteners VersiWeld BA <br /> Min.22 ga.,type B, (Optional)One or more layers,any VersiWeld/Aqua Base 120 BA or <br /> SC-37 Grade 33 steel or min. combination,loose laid Min.1-inch ACFoam II or ENRGY 3 See Note 2 1 per 1.6 ftZ VersiWeld BA -37.5* <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.25-inch SECUROCK Gypsum-Fiber Z <br /> SC-38 Grade 33 steel or min. layers,any combination,loose laid Roof Board See Note 2 1 per 2.67 ft VersiWeld/Low VOC BA -37.5'" <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min.0.5-inch SecurShield HD or H-Shield Z VersiWeld/VersiWeld BA or Low VOC <br /> rad�33-S�e�mi layers,any com ination, oose ai HD ' BA ' <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.25-inch SECUROCK Gypsum-Fiber Z VersiWeld/Aqua Base 120 BA, , <br /> SC-40 Grade 33 steel or min. See Note 2 1 per 2.67 ft -37.5 <br />-- --- 2;SOOpsi concrete <br /> la�,any combination,loose laid Roof eoard VersiWeld BA or Low VOC BA -- - <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.25-inch SECUROCK Gypsum-Fiber Z VersiWeld/Aqua Base 120 BA, 4 <br /> SC-41 Grade 33 steel or min. layers,any combination,loose laid Roof Board See Note 2 1 per 2.0 ft VersiWeld BA or Low VOC BA -45.0 <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.50-inch SECUROCK Gypsum-Fiber Z VersiWeld/Aqua Base 120 BA, „ I� <br /> SC-42 Grade 33 steel or min. See Note 2 1 per 3.2 ft -45.0 �I <br /> layers,any combination,loose laid Roof Board VersiWeld BA or Low VOC BA I <br /> 2,500 psi concrete I <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.625-inch SECUROCK Gypsum-Fiber x VersiWeld/Aqua Base 120 BA, * <br /> SC-43 Grade 33 steel or min. layers,any combination,loose laid Roof Board See Note 2 1 per 4.0 ft VersiWeld BA or Low VOC BA -45.0 <br /> 2,500 psi concrete i <br /> SC-44 Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 7/16-inch APA or TECO rated OSB Trufast SIP LD 1 per 2.67 ft2 VersiWeld/Aqua Base 120 BA or _q5.0* <br /> Grede 33 steel layers,any combination,loose laid Fasteners VersiWeld BA <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more � ' P VersiWeld/Aqua Base 120 BA or <br /> SC-45 Grade 33 steel or min. layers,any combination,loose laid Min 7 16-inch APA or TECO rated OSB See Note 2 1 er 3.6 ft2 VersiWeld BA -45.0* <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, O tional One or more la ers,an Min.1-inch Pol isoc anurate MP-H,H- VersiWeld/A ua Base 120 BA or <br /> SC-46 Grade 33 steel or min. �ombination,loose laid Y Y Shield,SecurSh eld,H-Shield CG See IVote 2 1 per 1.6 ftZ VersiWeld BA9 -45.0* <br /> 2,500 psi cancrete <br /> Min.22 a., e B, Min.1.5-inch ACFoam II,Polyisocyanurete <br /> g �p (Optional)One or more layers,any Z VersiWeld/Aqua Base 120 BA or �, <br /> SC-47 Grade 33 steel or min. combination,loose laid MP-H,H-Shield,SecurShield,H-Shield CG, See Note 2 1 per 2.0 ft VersiWeld BA �45'o <br /> 2,500 psi concrete ENRGY 3 <br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6 <br /> Certificate of Authorization tt9503 Revision 5:06/19/2014 <br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 10 of 36 <br />