_ ^ I
<br /> . i
<br /> TRINIIY�ERD
<br /> TABLE 2B:STEEL oa CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Teaa-OFF)oa RECOVER
<br /> SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
<br /> System Deck Top Insulation Layer Roof Cover Adhesive MDP s
<br /> Base Insulation Layer T e Fasteners Attach � �P�
<br /> No. (See Note 1) YP
<br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.1.5-inch Polyisocyanurete MP-H,H- Versico AccuTrac Z VersiWeld A ua Base 120 BA,
<br /> SC-48 Grade 33 steel or min. combination,loose laid Shield,SecurShield,H-Shield CG with Accu7rec Plate 1 per 3.2 ft VersiWeld BA or Low VOC BA -45.0*
<br /> 2,500 psi concrete
<br /> Min.22 ga.,type B, �Optional)One or more layers,any Min.1.5-inch SecurShield HD Composite, Z VersiWeld/VersiWeld BA or Low VOC „
<br /> SC-49 Grede 33 steel or min. �ombination,loose laid H-Shield HD Composite See Note 2 1 per 2.0 ft BA -45.0
<br /> 2,500 psi concrete
<br /> Min.22 ga.,type B, Min.2.0-inch ACFoam II,Polyisocyanurate VersiWeld A
<br /> (Optional)One or more layers,any MP-H,H-Shield,SecurShield,H-Shield CG, See Note 2 1 er 4.0 ft� / qua Base 120 BA or _q5.0*
<br /> SC-50 Grade 33 steel or min. combination,loose laid p
<br /> 2,500 psi concrete ENRGY 3 VersiWeld BA
<br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.2.0-inch SecurShield HD Composite, Z VersiWeld/VersiWeld BA or Low VOC „
<br /> SC-51 Grade 33 steel or min. �ombination,loose laid H-Shield HD Composite See Note 2 1 per 4.0 ft BA -45.0
<br /> 2,500 psi concrete
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min.0.5-inch SecurShield HD or H-Shield VersiWeld/VersiWeld BA or Low VOC
<br /> SC-52 Grade 33 steel or min. layers,any combination,loose laid HD See Note 2 1 per 2.0 ftx BA -45.0"
<br /> 2,500 psi concrete
<br />_ _-- -Min.-1-:S-inch-Polyisocyanurate-MP- - -- -
<br /> Min.22 ga.,type B, H,MP-N or MP-W,H-Shield, Z VersiWeld/VersiWeld BA or Low VOC w
<br /> SC-53 Grade 33 steel or SecurShield,H-Shield CG,ENRGY 3 Min.0.5-inch SecurShield HD Plus See Note 2 1 per 4 ft BA -45.0
<br /> structural concrete or ACFoam II
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more z
<br /> SC-54 Grade 33 steel or min. �ayers,any combination,loose laid Min 7/16-inch APA or TECO rated OSB See Note 2 1 per 1.9 ft VersiWeld/Aqua Base 120 BA -52.5
<br /> 2,500 psi concrete
<br /> Min.1.5-inch Polyisocyanurate MP-
<br /> Min.22 ga.,type B, H,MP-N or MP-W,H-Shield, VersiWeld/VersiWeld BA or Low VOC
<br /> SC-55 Grade 33 steel or SecurShield,H-Shield CG,ENRGY 3 Min.0.5-inch SecurShield HD Plus See Note 2 1 per 1.78 ftZ BA -60.0
<br /> structural concrete or ACFoam II
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more
<br /> SC-56 Grede 33 steel or min. layers,any combination,loose laid Min 0.5-inch Dens Deck Prime See Note 2 1 per 1.6 ftZ VersiWeld/VersiWeld BA -60.0
<br /> 2,500 psi concrete
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more �
<br /> SC-57 Grede 33 steel or min. Min 7/16-inch APA or TECO rated OSB See Note 2 1 per 1.9 ft VersiWeld/VersiWeld BA -75.0
<br /> 2,500 psi concrete layers,any combination,loose laid
<br /> Min.22 ga.,type B, Min 2.0-inch ACFoam II,Polyisocyanurete
<br /> SC-58 Grade 33 steel or min. (Optional)One or more layers,any MP-H,H-Shield,SecurShield,H-Shield CG, See Note 2 1 per 1.6 ft2 VersiWeld/VersiWeld BA -75.0
<br /> 2,500 psi concrete �ombination,loose laid ENRGY 3
<br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.2.0-inch SecurShield HD Composite, 2 VersiWeld/VersiWeld BA or Low VOC
<br /> SC-59 Grade 33 steel or min. combination,loose laid H-Shield HD Composite See Note 2 1 per 1.6 ft BA -75.0
<br /> 2,500 psi concrete
<br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6
<br /> Certificate of Authorization#9503 Revision 5.06/19/2014
<br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 11 of 36
<br />
|