_ ^ I <br /> . i <br /> TRINIIY�ERD <br /> TABLE 2B:STEEL oa CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Teaa-OFF)oa RECOVER <br /> SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER <br /> System Deck Top Insulation Layer Roof Cover Adhesive MDP s <br /> Base Insulation Layer T e Fasteners Attach � �P� <br /> No. (See Note 1) YP <br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.1.5-inch Polyisocyanurete MP-H,H- Versico AccuTrac Z VersiWeld A ua Base 120 BA, <br /> SC-48 Grade 33 steel or min. combination,loose laid Shield,SecurShield,H-Shield CG with Accu7rec Plate 1 per 3.2 ft VersiWeld BA or Low VOC BA -45.0* <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, �Optional)One or more layers,any Min.1.5-inch SecurShield HD Composite, Z VersiWeld/VersiWeld BA or Low VOC „ <br /> SC-49 Grede 33 steel or min. �ombination,loose laid H-Shield HD Composite See Note 2 1 per 2.0 ft BA -45.0 <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.2.0-inch ACFoam II,Polyisocyanurate VersiWeld A <br /> (Optional)One or more layers,any MP-H,H-Shield,SecurShield,H-Shield CG, See Note 2 1 er 4.0 ft� / qua Base 120 BA or _q5.0* <br /> SC-50 Grade 33 steel or min. combination,loose laid p <br /> 2,500 psi concrete ENRGY 3 VersiWeld BA <br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.2.0-inch SecurShield HD Composite, Z VersiWeld/VersiWeld BA or Low VOC „ <br /> SC-51 Grade 33 steel or min. �ombination,loose laid H-Shield HD Composite See Note 2 1 per 4.0 ft BA -45.0 <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min.0.5-inch SecurShield HD or H-Shield VersiWeld/VersiWeld BA or Low VOC <br /> SC-52 Grade 33 steel or min. layers,any combination,loose laid HD See Note 2 1 per 2.0 ftx BA -45.0" <br /> 2,500 psi concrete <br />_ _-- -Min.-1-:S-inch-Polyisocyanurate-MP- - -- - <br /> Min.22 ga.,type B, H,MP-N or MP-W,H-Shield, Z VersiWeld/VersiWeld BA or Low VOC w <br /> SC-53 Grade 33 steel or SecurShield,H-Shield CG,ENRGY 3 Min.0.5-inch SecurShield HD Plus See Note 2 1 per 4 ft BA -45.0 <br /> structural concrete or ACFoam II <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more z <br /> SC-54 Grade 33 steel or min. �ayers,any combination,loose laid Min 7/16-inch APA or TECO rated OSB See Note 2 1 per 1.9 ft VersiWeld/Aqua Base 120 BA -52.5 <br /> 2,500 psi concrete <br /> Min.1.5-inch Polyisocyanurate MP- <br /> Min.22 ga.,type B, H,MP-N or MP-W,H-Shield, VersiWeld/VersiWeld BA or Low VOC <br /> SC-55 Grade 33 steel or SecurShield,H-Shield CG,ENRGY 3 Min.0.5-inch SecurShield HD Plus See Note 2 1 per 1.78 ftZ BA -60.0 <br /> structural concrete or ACFoam II <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more <br /> SC-56 Grede 33 steel or min. layers,any combination,loose laid Min 0.5-inch Dens Deck Prime See Note 2 1 per 1.6 ftZ VersiWeld/VersiWeld BA -60.0 <br /> 2,500 psi concrete <br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more � <br /> SC-57 Grede 33 steel or min. Min 7/16-inch APA or TECO rated OSB See Note 2 1 per 1.9 ft VersiWeld/VersiWeld BA -75.0 <br /> 2,500 psi concrete layers,any combination,loose laid <br /> Min.22 ga.,type B, Min 2.0-inch ACFoam II,Polyisocyanurete <br /> SC-58 Grade 33 steel or min. (Optional)One or more layers,any MP-H,H-Shield,SecurShield,H-Shield CG, See Note 2 1 per 1.6 ft2 VersiWeld/VersiWeld BA -75.0 <br /> 2,500 psi concrete �ombination,loose laid ENRGY 3 <br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.2.0-inch SecurShield HD Composite, 2 VersiWeld/VersiWeld BA or Low VOC <br /> SC-59 Grade 33 steel or min. combination,loose laid H-Shield HD Composite See Note 2 1 per 1.6 ft BA -75.0 <br /> 2,500 psi concrete <br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6 <br /> Certificate of Authorization#9503 Revision 5.06/19/2014 <br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 11 of 36 <br />