<br /> TABLE 28:STEEL oa CONCRETE pECKS-NEW CONSTRUCTION,REROOF(TEnR-O�F)oa RECOVER
<br /> SYSTEM TYPE Gl:MECHANICALLYA7TACHED INSULATION,BQNDED ROOF COVER
<br /> System Deck Base Insulation La er Top Insuiation Layer
<br /> No. (See Note i) y Type Fasteners Attach �oof Cover/Adhesive MDP(ps�
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.5-inch SECUROCK Gypsum-Fiber
<br /> SC-60 Grade 33 steel or min, layers,any combination,loose laid Roof Board See Note 2 1 per 1.6 ftZ VersiWeld/Low VpC BA -7S.p
<br /> 2,Sa0 psiconcrete
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.5-inch SECUROCK Gypsum-Fiber
<br /> SC-61 Grade 33 steel or min. layers,any combination,loose laid Roof Baard See Note 2 1 per 1.6 ftZ VersiWeld/VersiWeld BA -82.5
<br /> 2,540 psi cancreta
<br /> Min.22 ga.,type 8, Min.1.5-inch thick,one or more
<br /> SC-62 Grade 33 steel or min. ��Yers,any combination,loose laid Min 7/16-inch APA or TECO rated OSB See Note 2 1 per 1 ft� VersiWeld/VersiWeld BA -g7,5
<br /> 2,500 psiconcrete
<br /> Min.20 ga.,type B, (Optional)Min.1.5-inch thick,one Min.0.625-inch SECUROCK Gypsum-Fiber
<br /> SC-63 Grade 33 steel or min. or more layers,any combination, Roaf Soard See Note 2 1 per 1.33 ft2 VersiWeld/VersiWeld BA -112.5
<br /> 2 540 si concrete loose Iaid
<br /> Min.18 ga.,type B, Min.2-inch thick,one or more Min.O.S-inch SECUROCK 6ypsum-Fiber
<br /> SC-64 Grade 33 steel or min. tayers,any cambinatian,loose iaid Roaf Board See Note 2 1 per 1.33 ft2 VersiWeld/VersiWeld BA -1125 �
<br /> 2,500 psi concreta
<br /> Min.22 ga.,type B, -Min.-1:5-inch-Polyispcyanurate MP-- - - - — — - ----
<br /> H,MP-N or MP-W,N-Shieid, 2 VersiWeid f VersiWetd BA or law VOC
<br /> SC-65 Grade 33 steet or SecurShield,H-Shield C6,ENRGY 3 M�n.0.5-inch SecurShie(d HD Plas See Note 2 1 per 1.33 ft BA -112.5
<br /> structural Concrete pr ACFoam II
<br /> M3n.22 ga.,type B, Min.1.5-inch thick,one or mare Min.2.0-inch SecurShield HD Com asite, (
<br /> SC-66 Grade 33 steel or min. � See Note 2 1 per 1 ftZ VersiWe(d J VersiWe2d BA orlow V4C ��Z 5
<br /> 2,500 psi concrete layers,any combination,loose laid H-Shield HD Composite gA
<br /> Min.22 ga.,type B, �pptional}One or more Iayers,any i
<br /> SC-67 Grade 33 steel or min. combination,loose laid Min 2-inch SecurShield,H-Shield C6 See Note 2 1 per 1 ft� VersiWeld/VersiWeld BA -120.0 I
<br /> 2,5a0 psi cancrete �
<br /> Min.22 ga.,type 6, Min.1.5-inch thick,one or more Min 0.5-inch SECUROCK Gypsum-Piber I
<br /> SC-68 Grade 33 sYeel or min. layers,any combination,loose laid Roof Board See Note 2 1 per 1 ftZ VersiWeld/Low VOC BA -127.5
<br /> 2,SQ4 psi coacrete '
<br /> i
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more
<br /> SC-69 Grade 33 steel or min. �ayers,any combination,loose laid Min.2.0-inch SecurShield or H-Shield CG See Note 2 1 per 1 ftZ VersiWeld/Low VOC BA -127.5 I
<br /> 2,540 psi cancrete
<br /> VERSIFLEECE MEMBRANE ApPLICATIONS�SEE NOTE 17�:
<br /> Min.22 ga.,rype B, {qPtional}One or mare layers,any tviin.l.5-inch Ppiyisocyanurate MP-N,H- Versico AauTrac VersiFieece f FAST 100 LV or Fiexibte
<br /> SG70 Grade 33 steel or min. combination,Ioose Iaid Sfiield,SecurShield,H-Shield C6 with AccuTrec Piate �-p�r 3'2 ftZ -45.4"
<br /> 2,500 psi concrete
<br /> FAST,futi coverege
<br /> Min.22 ga.,type B, {pPtional}One or mare layers,any Min.l.S-inch Polyisocyanurate MP-H,H- VersiFleeee f FAST 1d0 or FAST S00
<br /> SC-�1 Grade 33 steet or min. See Note 2 1 per 3.2 ft= -45.0*
<br /> 2,500 psi concrete combination,toose laid Shieid,SecurShield,H-Shieid CG LV,max.12-inch o.c.
<br /> Eaderior Research and Design,LIC.dJbJa Trinity�ERD Evaluation Report C35230.11.10-RS for FL14207-R6
<br /> Certificate of Authorization#9503 Revision 5:06/19/2014
<br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 12 of 36