TRINIIY l ERD
<br /> TABLE 2B:STEEL oR CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Teaa-OFF)oR RECOVER
<br /> SYSTEM TYPE C-1:MECHANICA6LY ATTACHED INSULATION,BONDED ROOF COVER
<br /> System Deck gase Insulation Layer Top Insulation Layer Roof Cover/Adhesive MDP(psf)
<br /> No. (See Note 1) Type Fasteners Attach
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more VersiFleece/FAST 100,FAST 100 LV,
<br /> SC-83 Grede 33 steel or min. layers,any combination,loose laid Min 7/16-inch APA or TECO rated OSB See Note 2 1 per 1 ftZ Flexible FAST,full coverage at 0.5 -135.0
<br /> 2,500 psi concrete gal/sq.
<br /> Min.22 ga.,type B, Min.1.5-inch thick,one or more Min 0.5-inch SECUROCK Gypsum-Fiber VersiFleece/FAST 100,FAST 100 LV,
<br /> SC-84 Grade 80 steel or min. layers,any combination,loose laid Roof Board See Note 2 1 per 1 ftZ ribbons max.4-inch o.c.or full -135.0
<br /> 2,500 psi concrete coverage
<br /> Min.22 ga.,type B, (Optional)One or more layers,any Min.2.0-inch SecurShield HD Composite, VersiFleece/FAST 100 LV,ribbons
<br /> SC-85 Grade 33 steel or min. combination,loose laid H-Shield HD Composite See Note 2 1 per 1 ft� max.4-inch o.c.or full coverege -157.5
<br /> 2,500 psi concrete
<br /> VERSIWELD QA MEMBRANE APPLICATIONS:
<br /> Min.22 ga.,type B, (Optional for Recover)Min.1.5-
<br /> - - � , f-adher - .
<br /> 2,500 psi concrete combination,loose laid
<br /> _ Min.22 ga.,type B, (Optional for Recover)Min.1.5-
<br /> SC-87 Grede 33 steel or min. inch thick,one or more layers,any Min.2-inch Insulfoam SP See Note 2 1 per 2.0 ftZ VersiWeld Qq,self adhered -45.0`
<br /> ----—2;SOO psi concrete -combination,-loose laid
<br /> Min.22 ga.,type B, (Optional for Recover)Min.1.5- Min.0.25-inch Dens Deck Prime or
<br /> SC-88 Grade 33 steel or min. inch thick,one or more layers,any SECUROCK Gypsum-Fiber Roof Board or See Note 2 1 per 2.0 ftZ VersiWeld Qq,self adhered -45.0*
<br /> 2,500 psi concrete combination,loose laid min 7/16-inch APA orTECO rated OSB
<br /> Min.22 ga.,type B, (Optional)Min.1.5-inch thick,one Min.1.5-inch Polyisocyanurate MP-H,H-
<br /> SC-89 Grade 33 steel or min. or more layers,any combination, Shield,SecurShield,H-Shield CG See Note 2 1 per 2.0 ftx VersiWeld QA,self adhered -45.0'"
<br /> 2,500 psi concrete loose laid
<br /> Min.22 ga.,type B, (Optional)Min.1.5-inch thick,one Min.2.0-inch Polyisocyanurate MP-H,H- 2
<br /> SC-90 Grade 33 steel or min. or more layers,any combination, Shield,SecurShield,H-Shield CG See Note 2 1 per 1.6 ft VersiWeld qq,self adhered -60.0
<br /> 2,500 psi concrete loose laid
<br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6
<br /> Certificate of Authorization#9503 Revision 5:06/19/2014
<br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 14 of 36