Laserfiche WebLink
TRI�I�,�ERD <br /> TABLE 38:CONCRETE DECKS—NEW CONSTRUCTION oR REROOF(Teaa-OFF) <br /> SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER <br /> System Roof Cover <br /> No. Deck Primer Type Attach MDP(psf) <br /> -VERSIFLEECE MEMBRANEAPPLICATIONS(SEE NOTE 17�:; - _ - " <br /> C-46. Gypsum concrete None VersiFleece FAST 100,FAST 100 LV,Flexibie FAST,full coverege. -295.0 I <br /> C-47 Structural concrete None VersiFleece FAST 100,FAST 100 LV,Flexible FAST,full coverege. -495.0 , <br /> VERSIFLEECE AC M EMBRANE APPLICATIONS: ' <br /> C-a8. Structural concrete None VersiFleece AC Hot Asphalt — _g7,5 <br /> C-49. Structural concrete CCW-702 or cut-back VersiFleece AC Hot Asphalt <br /> primer at 250-300 ftZ/gal -495.0 <br /> VERSIWELD Q/�MEMBMNE APPLICATIONS: ' � <br /> c-so. Structural concrete None VersiWeld QA Seif-adhered -425.0 <br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6 <br /> Certificate of Authorization#9503 Revision 5:06/19/2014 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 24 of 36 <br />