My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-15894
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-15894
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2015 10:47:53 AM
Creation date
11/16/2015 10:45:33 AM
Metadata
Fields
Template:
Building Department
Company Name
ALL ABOUT YOU SALON & DAY SPA
Building Department - Doc Type
Permit
Permit #
15-15894
Building Department - Name
ALL ABOUT YOU SALON & DAY SPA
Address
38016 15TH AVE LOT 1 & 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> - F; <br /> TRINIIY,ERD <br /> TABLE 4C-1:LIGHTWEIGHT CONCRETE OVER STEEL DECK-NEW CONSTRUCTION OR RE-ROOF(TEAR OFF) <br /> SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER <br /> Deck(See Note i) Roof Cover <br /> System Su IementalAttachment MDP sf <br /> No Surface pp (P ) <br /> Struct.Deck �W�� Treatment Type Attach <br /> Fasteners Density <br /> Min.22 ga.,Type B,Grade 33 Min.36 pcf wet cast density,min.200 psi,min.2-inch HPV Fastener with FAST 100,FAST 100 LV, <br /> LWC-13 steel at max.6 ft spans thick Celcore MF Cellular Concrete(cast with or without Celcore PVA HPV Insulation 1 per 1 ftZ VersiFleece Flexible FAST,ribbons -120.0 <br /> attached 6-inch o.c. min.1-inch EPS holey board). See Note A. Fastening Plate max.4-inch o.c.or full 5ee Note e <br /> coverage. <br /> Note A.J If the LWC to be used on ihe project is not Celcore MF,or if the LWC is existing in a re-roof(tear-ojfJ condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive <br /> strength testing shall be in occordonce with ASTM C495(for new pourJ or ASTM C109(for existing)and shall yield o minimum 200 psi result. Field withdrawal resistonce testing in accordance with TA5105 or ANSI/SPRI FX-1 <br /> and shall yield on average withdrawal performance not less thon SS lbf with an ES Produd FM-90 Base Sheet Fastener. If question exists as to the adhesion to the LWCsurfoce,field testing in occordance with ASTM E907 or <br /> FM CPDS 1-29 is recommended.All testing shall be perfarmed by an accredited testing agency acceptoble to the AHJ. <br /> Note B.J Linear interpolation between supplemental attochment at 1 per 9 ftz for-67.5 psf ond 1 per 1 ftz for-120.0 psf is permissible. Such interpolation shall be performed by o quolified design professional to the <br /> satisj � . <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report C35230.11.10-RS for FL14207-R6 <br /> Certificate of Authorization#9503 Revision 5:06/19/2014 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 27 of 36 <br />