Laserfiche WebLink
G <br /> � � <br /> TRINIIY I ERD <br /> TABLE4C-2:LIGHTWEIGHTCONCRETEOVERSTRUCTURALCONCRETE—NEWCONSTRUCTION <br /> SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER <br /> System Deck Roof Cover MDP sf <br /> No. Roof Deck LWC Membrane Application (P � <br /> VERSIW ELD M EMBRANE APPLICATIONS: <br /> LWC-14 Min.2,500 psi concrete Min.250 psi,Min.2-inch thick,Elastizell Range II LWIC VersiWeld Aqua Base 120 BA -67.5 <br /> LWC-15 Min.2,500 psi concrete Min.250 psi,Min.2-inch thick,Elastizell Range II LWIC VersiWeld VersiWeld BA -90.0 <br /> LWC-16 Min.2,500 psi concrete Min.300 psi,Min.2-inch thick,Celcore Cellular Concrete VersiWeld Aqua Base 120 BA -82.5 <br /> LWC-17 Min.2,500 psi concrete Min.300 psi,Min.2-inch thick,Celcore Cellular Concrete VersiWeld VersiWeld BA -135.0 <br /> Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF <br /> LWC-18 Min.2,500 psi concrete Cellular Concrete(cast with or without min.1-inch EPS holey board). See VersiWeld Aqua Base 120 BA -217.5 <br /> Note A. <br /> Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF <br /> LWC-19 Min.2,500 psi concrete Cellular Concrete(cast with or without min.l-inch EPS holey board). See VersiWeld VersiWeld BA -480.0 <br /> Note A. <br /> VERSIFLEECE MEMBRANE APPLILATIONS: <br /> LWC-20 Min.2,500 psi concrete _ Min.250 psi,Min.2-inch thick,Elastizell Range II LWIC VersiFleece Aqua Base 120 BA -90.0 <br /> LWC-21 Min.2,500 psi concrete Min.300 psi,Min.2-inch thick,Celcore Cellular Concrete VersiFleece Aqua Base 120 BA -135.0 <br /> Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF FAST 100,FAST 100LV or Flexible FAST, <br /> LWC-22 Min.2,500 psi concrete Cellular Concrete(cast with or without min.1-inch EPS holey board). See VersiFleece ribbons max.4-inch o.c.or full coverage. 'Z32.5 <br /> Note A. <br /> Min.36 pcf wet cast density,min.200 psi,min.2-inch thick Celcore MF <br /> LWC-23 Min.2,500 psi concrete Cellular Concrete(cast with or without min.1-inch EPS holey board). See VersiFleece Aqua Base 120 BA -525.0 <br /> Note A. <br /> VERSIWELD QA MEMBRANE APPLICATIONS: <br /> LWC-24 Min.3,000 psi concrete Min.250 psi,Min.2-inch thick,Elastizell Range II LWIC VersiWeld QA Self-adhered -282.5 <br /> Note A.J If the LWC to be used on fhe project is not Celcore MF,or if the LWC is existing in a re-roof(tear-of�condition,compressive strength and fastener withdrawal resistance testing shall be conducted. Compressive <br /> strength testing shall be in accordance with ASTM C495(for new pour)or ASTM C109(for existing)and shall yield a minimum 200 psi result. Field withdrawol resistance testing in accordance with TA5105 or AN51/SPRI FX-1 <br /> and shall yield an average withdrawal performance not less thon SS lbf with an ES Product FM-90 Base Sheet Fastener. !f question exists os to the adhesion to the LWC surface,field testing in accordance with ASTM E907 or <br /> FM LPDS 1-29 is recommended.All testing shall be performed by an accredited testing agency acceptable to the AHI. <br /> Exterior Research and Design,LLC.d/b/a Trinity� ERD Evaluation Report C35230.11.10-RS for FL14207-R6 <br /> Certificate of Authorization#9503 Revision 5:06/19/2014 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 28 of 36 <br />