Laserfiche WebLink
z <br />List Of Abbreviations <br />A <br />A/C <br />AIR CONDITION <br />E <br />EL <br />ELEVATION <br />AB <br />ANCHOR BOLT <br />ELEC <br />ELECTRICAL <br />ACT <br />ACOUSTICAL CEILING TILE <br />ELEV <br />ELEVATOR <br />AD <br />ADJUSTABLE,ADJACENT <br />EMER <br />EMERGENCY <br />AFF <br />ABOVE REF FINISHED <br />EQ <br />EQUAL <br />FLOOR (SLAB) <br />EQUIP <br />EQUIPMENT <br />AHU <br />AIR HANDLER UNIT <br />ESC <br />ESCALATOR <br />ALT <br />ALTERNATE <br />EWC <br />ELECTRIC <br />ALUM <br />ALUMINUM <br />WATER COOLER <br />ANOD <br />ANODIZED <br />EXIST <br />EXISTING <br />APPROX APPROXIMATE <br />EXP <br />EXPANSION <br />ARCH <br />ARCHITECT <br />EXT <br />EXTERIOR <br />AUTO <br />AUTOMATIC <br />F <br />FACP <br />FIRE ALARM <br />B <br />B O <br />BOTTOM OF <br />CONTROL PANEL <br />BD <br />BOARD <br />FO <br />FLOOR DRAIN <br />BLDG <br />BUILDING <br />FDN <br />FOUNDATION <br />BM <br />BEAM <br />FIN <br />FINISHED <br />BRG <br />BEARING <br />FLR <br />FLOOR <br />BTM <br />BOTTOM <br />FR <br />FIRE RESISTANT <br />BUR <br />BUILT UP ROOF <br />FR-S <br />FIRE -RETARDANT <br />WOOD TREATMENT <br />C <br />CB <br />CATCH BASIN <br />FT <br />FEET, FOOT <br />CG <br />CORNER GUARD <br />FTG <br />FOOTING <br />CI <br />CAST IRON <br />FURR <br />FURRING <br />CJ <br />CONTROL JOINT <br />FLIT <br />FUTURE <br />CL <br />CENTER LINE <br />CLG <br />CEILING <br />G <br />GA <br />GAUGE <br />CLO <br />CLOSET <br />GAL <br />GALLON <br />CLR <br />CLEAR <br />GALV <br />GALVANIZED <br />CMU <br />CONCRETE <br />GB <br />GRAB BAR <br />MASONRY UNIT <br />GC <br />GENERAL CONTRACTOR <br />CO <br />CLEAN OUT <br />GYP <br />GYPSUM <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />H <br />HB <br />HOSE BIBB <br />CONST <br />CONSTRUCTION <br />HC <br />HOLLOW CORE <br />CONT <br />CONTINUOUS <br />HDW <br />HARDWARE <br />CONTR <br />CONTRACTOR <br />HM <br />HOLLOW METAL <br />CORR <br />CORRIDOR <br />HORIZ <br />HORIZONTAL <br />CT <br />CERAMIC TILE <br />HR <br />HOUR <br />CTR <br />CENTER <br />HT <br />HEIGHT <br />CU <br />CONDENSING UNIT <br />HTG <br />HEATING <br />CW <br />COLD WATER <br />HVAC <br />HEATING, VENTILATING <br />& AIR CONDITIONING <br />D <br />DBL <br />DOUBLE <br />HW <br />HOT WATER <br />DEPT <br />DEPARTMENT <br />DET <br />DETAIL <br />I <br />ID <br />INSIDE DIAMETER <br />DF <br />DRINKING FOUNTAIN <br />IN <br />INCH <br />DIA <br />DIAMETER <br />INCL <br />INCLUDING <br />DIM <br />DIMENSION <br />INSUL <br />INSULATION <br />DISP <br />DISPENSER <br />INT <br />INTERIOR <br />DN <br />DOWN <br />INV <br />INVERT <br />DS <br />DOWNSPOUT <br />DWG <br />DRAWING <br />J <br />JAN <br />JANITOR <br />E <br />JB <br />JUNCTION BOX <br />EA <br />EACH <br />JT <br />JOINT <br />EB <br />EXPANSION BOLT <br />EIFS <br />EXTERIOR INSULATING <br />L <br />L <br />LENGTH <br />FINISH SYSTEM <br />LAM <br />LAMINATE <br />EJ <br />EXPANSION JOINT <br />Legend <br />102 <br />102A <br />O <br />0 <br />i1 TO SOMETHING <br />L LAV <br />LAVATORY <br />LBL <br />LABEL <br />LBS <br />POUNDS <br />LF <br />LINEAR FEET <br />LT WT <br />LIGHT WEIGHT <br />M MAS <br />MASONRY <br />MAX <br />MAXIMUM <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />MH <br />MANHOLE <br />MIN <br />MINIMUM <br />MIN <br />MINIMUM, MINUTE <br />MISC <br />MISCELLANEOUS <br />MLDG <br />MOLDING <br />MO <br />MASONRY OPENING <br />MR <br />MOISTURE RESISTANT <br />MTD <br />MOUNTED <br />MTL <br />METAL <br />MUL <br />MULLION <br />N NIC <br />NOT IN CONTRACT <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />0 OC <br />ON CENTER <br />OD <br />OUTSIDE DIAMETER <br />OPP <br />OPPOSITE <br />OVFL <br />OVERFLOW <br />P PL <br />PLATE <br />PLAM <br />PLASTIC LAMINATE <br />PLAS <br />PLASTER <br />PLBG <br />PLUMBING <br />PLWD <br />PLYWOOD <br />PNL <br />PANEL <br />PR <br />PAIR <br />PREFAB <br />PREFABRICATED <br />PT <br />POINT <br />PT <br />PRESSURE TREATED <br />PTD <br />PAPER TOWEL DISPENSER <br />PVC <br />POLY VINYL CLORIDE <br />Q QT <br />QUARRY TILE <br />R R <br />RADIUS, RISER, <br />THERMAL RESISTANCE <br />RD <br />ROOF DRAIN <br />RECP <br />RECEPTACLE <br />REF <br />REFERENCE <br />REFR <br />REFRIGERATOR <br />REG <br />REGLET <br />REINF <br />REINFORCEMENT <br />REQ <br />REQUIRED <br />REV <br />REVISION <br />RM <br />ROOM <br />RND <br />ROUND <br />RO <br />ROUGH OPENING <br />RTU <br />ROOF TOP UNIT <br />S SC <br />SOLID CORE <br />SCHED <br />SCHEDULE <br />SCP <br />SCUPPER <br />SD <br />SOAP DISPENSER <br />SEAL <br />SEALANT <br />SECT <br />SECTION <br />SF <br />SQUARE FEET <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />SPEC <br />SPECIFICATION <br />SS <br />STAINLESS STEEL, <br />SERVICE SINK <br />STD <br />STANDARD <br />STL <br />STEEL <br />STOR <br />STORAGE <br />STRUC <br />STRUCTURAL <br />SUSP <br />SUSPENDED <br />SY <br />SQUARE YARD <br />T T <br />TREAD <br />T&G <br />TONGUE & GROOVE <br />TBL <br />TABLE <br />TELE <br />TELEPHONE <br />TEMP <br />TEMPERED <br />THK <br />THICK <br />TLT <br />TOILET <br />TO <br />TOP OF <br />TPD <br />TOILET PAPER <br />DISPENSER <br />TS <br />TUBE STEEL <br />TV <br />TELEVISION <br />TYP <br />TYPICAL <br />U LION <br />UNLESS OTHER- <br />WISE NOTED <br />UTIL <br />UTILITY <br />V VB <br />VINYL BASE <br />VCT <br />VINYL COMPOSITE TILE <br />VERT <br />VERTICAL <br />VEST <br />VESTIBULE <br />VIF <br />VERIFY IN FIELD <br />VTR <br />VENT THRU ROOF <br />VWC <br />VINYL WALL COVERING <br />W W <br />WIDTH <br />W/ <br />WITH <br />W/O <br />WITHOUT <br />WC <br />WATER CLOSET <br />WD <br />WOOD <br />WH <br />WATER HEATER <br />WP <br />WATERPROOF <br />WT <br />WEIGHT <br />WWF <br />WELDED WIRE FABRIC <br />WWM <br />WELDED WIRE METAL <br />Y YD <br />YARD <br />GRID DESIGNATION Z= BUILDING SECTION <br />A301-2 A301-2 <br />ROOM NUMBER SHEET NUMBER SECTION NUMBER <br />DOOR NUMBER Z=✓ I11 WALL SECTION <br />A302-3 <br />WINDOW TYPE SHEET NUMBER SECTION NUMBER <br />STOREFRONT TYPE A501-6 SECTION DETAIL <br />WALL TYPE SHEET NUMBER DETAIL NUMBER <br />KEY NOTE A888-88 DETAIL REFERENCE <br />REVISION NUMBER SHEET NUMBER DETAIL NUMBER <br />ELEVATIONS TAGS _ EXTERIOR ELEVATION <br />A201-2 � �" MARKERS <br />SHEET NUMBER ELEVATION NUMBER <br />SPOT ELEVATION TAG <br />l <br />4 <;'A401 ;» 2 INTERIOR ELEVATION <br />NORTH ARROW MARKERS <br />SHEET NUMBER 3 ELEVATION NUMBER <br />General Notes <br />1. ALL WORK WILL COMPLY WITH LOCAL, STATE, AND NATIONAL CODES <br />RELATED TO THIS PROJECT. <br />2. THE WRITTEN DIMENSIONS ON THE CONSTRUCTION DOCUMENTS <br />PREVAIL. DO NOT SCALE THESE DRAWINGS. CONTRACTOR TO VERIFY <br />ALL DIMENSIONS AND CONDITIONS IN THE FIELD. IF ANY DISCREPANCY <br />OCCURS, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT <br />IN WRITING BEFORE PROCEEDING WITH ANY WORK AFFECTED. <br />3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS <br />NECESSARY TO OBTAIN A CERTIFICATE OF OCCUPANCY. <br />4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND <br />INFRASTRUCTURE REQUIRED TO PERFORM THE WORK, INCLUDING <br />FIRE PROTECTION AS REQUIRED DURING CONSTRUCTION. <br />5. EACH CONTRACTOR AND SUBCONTRACTOR IS EXPECTED TO REVIEW ALL <br />CONTRACT DOCUMENTS AND SITE CONDITIONS PRIOR TO ISSUED BID, <br />CHANGE ORDERS WILL NOT BE APPROVED FOR FAILURE TO DO SO. <br />6. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT <br />DOCUMENTS SHALL NOT BE SUBSTITUTED WITHOUT PRIOR WRITTEN <br />APPROVAL FROM THE ARCHITECT AND OWNER. <br />7. CONTRACTOR SHALL HAVE INSTALLATION INSTRUCTIONS FOR ALL <br />EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION. <br />8. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO <br />COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF <br />THE FACILITY AS PLANNED. <br />9. THE EXISTING SHELL BUILDING HAS A FIRE SPRINKLER SYSTEM AND <br />A FIRE ALARM SYSTEM. BOTH SYSTEMS SHALL BE MODIFIED AS <br />NEEDED TO PROVIDE FIRE PROTECTION FOR THE SPECIFIED <br />TENANT SPACE(S). THE CONTRACTOR SHALL SUBMIT SIGNED AND <br />SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE <br />LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. NO WORK ON <br />THE FIRE PROTECTION SYSTEM SHALL TAKE PLACE UNTIL THE <br />APPROPRIATE PERMITS ARE OBTAINED BY THE FIRE PROTECTION <br />SUB CONTRACTOR. <br />10. ALL BUILDING MATERIALS SHALL COMPLY WITH THE REQUIREMENTS <br />OF TYPE II-B CONSTRUCTION. ALL PLYWOOD SHEATHING AND <br />WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED (FRT) <br />11. ALL WORK ON THE EXISTING BUILDING SHALL BE PERFORMED IN <br />ACCORDANCE WITH ALL EXISTING WARRANTIES. THE GENERAL <br />CONTRACTOR SHALL CONTACT THE OWNER DIRECTLY TO OBTAIN <br />ALL EXISTING WARRANTY INFORMATION. THE CONTRACTOR SHALL <br />PROVIDE THE OWNER WITH DOCUMENTATION VERIFYING THAT ALL <br />EXISTING WARRANTIES HAVE BEEN MAINTAINED. <br />Legal Description <br />A TRACT OF LAND LYING IN THE NORTHEAST 1/4 OF SECTION 34 AND IN THE NORTHWEST 1/4 OF SECTION 35, TOWNSHIP 25 <br />SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA. THE SAME BEING A PORTION OF THE ZEPHYRHILLS COLONY COMPANT <br />LANDS SUBDIVISION OF SAID SECTION 34 AND 35 AS SHOWN ON THE PLAT OR MAP THEREOF RECORDED IN PLAT BOOK 1, PAGE <br />55 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br />LESS AND EXCEPT THAT PORTION OF SAID TRACTS 58 AND 59 CONVEYED IN OFFICIAL RECORDS BOOK 1902, PAGE 690, PUBLIC <br />RECORDS OF PASCO COUNTY, FLORIDA. <br />SAID LAND CONTAINING 60.76 ACRES MORE OR LESS. <br />Vicinity Map 'ND <br />NTS <br />7856 & 7860 GALL BLVD, ZEPHYRHILLS, FLORIDA <br />Code Information <br />JURISDICTION AUTHORITY <br />CITY OF ZEPHYRHILLS <br />5335 8TH STREET <br />ZEPHYRHILLS, FL 33542 <br />ADOPTED CODES: <br />3 SIGNED & SEALED SETS FOR PERMIT <br />(813) 780-0020 - PHONE <br />(813) 780-0021- FAX <br />BUILDING: <br />FBC, BUILDING - 2007 W/ 2009 SUPPLEMENTS <br />FIRE: <br />FLORIDA FIRE PREVENTION CODE - 2007 W/ 2009 SUPPLEMENTS <br />AND NFPA W/ FIRE MARSHAL AMENDMENTS <br />PLUMBING: <br />FBC, PLUMBING - 2007 W/ 2009 SUPPLEMENTS <br />MECHANICAL: <br />FBC, MECHANICAL - 2007 W/ 2009 SUPPLEMENTS <br />ELECTRICAL: <br />FBC, BUILDING CHAPTER 27 - 2007 W/ 2009 SUPPLEMENTS <br />AND NATIONAL ELECTRIC CODE - 2008 <br />ACCESSIBILITY: <br />FBC, BUILDING CHAPTER 11 - 2007 W/ 2009 SUPPLEMENTS <br />ENERGY: <br />FBC, BUILDING CHAPTER 13 - 2007 W/ 2009 SUPPLEMENTS <br />EXISTING BUILDING: <br />FBC, EXISTING BUILDING SECTION - 2007 W/ 2009 SUPPLEMENTS <br />CLASSIFICATION <br />THIS SCOPE IS CLASSIFIED AS A LEVEL 2 ALTERATION AS DEFINED BY SECTION 404.1 OF THE <br />EXISTING BUILDING CODE. THE SCOPE DOES NOT INCLUDE ANY CHANGE IN BUILDING SIZE, <br />OCCUPANCY CLASSIFICATION, OR OCCUPANT LOAD. <br />BUILDING AND CONSTRUCTION DATA <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP B - BUSINESS <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED <br />MAXIMUM HEIGHT AND AREA (FBC TABLE 503) <br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES <br />ACTUAL HEIGHT 35'-0" - ONE STORY <br />MAXIMUM AREA 23,000 SF <br />ACTUAL AREA 8,600 SF <br />AREA OF INTERIOR ALTERATION 2,400 SF <br />CHAPTER 13 - ENERGY EFFICIENCY <br />THIS BUILDING IS A PREVIOUSLY CONDITIONED SPACE THAT IS NOT UNDERGOING A CHANGE IN OCCUPANCY <br />OR A RENOVATION AS DEFINED BY SECTION 13-2 OF THE FBC. THEREFORE, PER FBC 13-101.5.1, COMPLIANCE <br />WITH THE ENERGY EFFICIENCY CODE IS NOT REQUIRED AND ENERGY CALCULATIONS ARE NOT REQUIRED. <br />NOTE: <br />WIND ZONE =110 MPH. IMPORTANCE FACTOR =1.00 <br />BLDG CATEGORY = II, ENCLOSED. WIND EXPOSURE = B <br />THE SCOPE OF WORK FOR THIS INTERIOR BUILD OUT DOES NOT INCLUDE ANY <br />MODIFICATIONS TO ANY EXTERIOR DOORS OR WINDOWS. ALL MODIFICATIONS <br />TO THE EXISTING ROOF SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH <br />THE MIAMI DADE NOTICE OF ACCEPTANCE (NOA). <br />Contact Information <br />CLIENT: <br />PRIMERICA GROUP ONE, INC. <br />3629 MADACA LANE <br />TAMPA, FL. 33618 <br />(813) 933-0629 PHONE <br />(813) 935-3420 FAX <br />CONTACT: ADAM ROBINSON <br />ARCHITECT, <br />CUHACI & PETERSON, ARCHITECTS, LLC <br />MECHANICAL <br />1925 PROSPECT AVE <br />ENGINEER, & <br />ORLANDO, FL 32814 <br />ELECTRICAL <br />(407) 661-9100 PHONE <br />ENGINEER: <br />(407) 661-9101 FAX <br />CONTACT: GABRIEL ROBERTSON <br />SUBMM'EH PLAN(S) AVE BEEN REVIE <br />BY ZEPHYRHILLS ItA$ A S () <br />Date: �I// jj <br />Reviewer: <br />Please be advised this review of plans submitted is a <br />cursory review to assist the contractor in compliance with <br />applicable fire safety codes. This review is not intended <br />to be a final approval of the submitted plans. It is the <br />contractor's sole responsibility to ensure that the plans are in <br />complete comp!Lr,�e Zvi¢= all applicable NFPA codes and <br />local ordinances. In the evert that fu Dr examination or <br />site inspection rove zis areas of ron-compl ante, it small be <br />the contractor's so.- responsibility, at their sole expense to <br />bring those areas in compliance. The City assumes no <br />responsib l:ty for the contractor's failure to be in compliance <br />with all applicable NFPA Codes and local ordinances. <br />Tenant Buildout for Space D3-D4 <br />Building D at Zephyr Commons <br />7856 & 7860 Gall Blvd, Zephyrhills, FL <br />SPACE D3 I . SPACE D4 <br />(AREA OF INTERIOR WORK) <br />ALL W0 <br />SRALL <br />C �E N N� IDES OW LY WITH <br />CITyOFZEPx AL ELE � ,C COB ILD&G <br />yRFIILLS QWDIN�NC AM) <br />LS <br />Scope of Work <br />1. THE SCOPE OF WORK ON THIS PROJECT IS AN INTERIOR BUILD OUT INSIDE OF AN EXISTING BUILDING. <br />2. THE SCOPE INCLUDES SEPARATING TENANT SPACES D3-D4 INTO TWO SEPARATE TENANT SPACES. <br />3. THE SCOPE IS LIMITED TO TENANT SPACES D3 & D4 IN BLDG D. <br />4. THE SCOPE INCLUDES SELECTIVE DEMOLITION AS SHOWN IN THE DRAWINGS. <br />5. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO THE SITE. <br />6. THE SCOPE DOES NOT INCLUDE ANY WORK ON ANY OF THE BUILDINGS OTHER THAN BLDG D. <br />7. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY SIDEWALKS OR LANDSCAPE AREAS. <br />8. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY OF THE EXTERIOR FINISHES. <br />9. THE SCOPE DOES NOT INCLUDE ANY WORK TO ANY OF THE EXTERIOR DOORS & WINDOWS. <br />10. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXISTING ROOF SYSTEM OTHER THAN WHAT IS <br />REQUIRED TO ADD AN EXHAUST FAN & VENT FOR THE NEW RESTROOM. <br />11. THE SCOPE ON THE FRONT FRAMED WALL SHALL BE LIMITED TO WHAT IS NEEDED TO CONSTRUCT THE <br />NEW TENANT DEMISING WALL.. THE EXISTING 1 HOUR FIRE RATING SHALL BE MAINTAINED. <br />12. THE SCOPE INCLUDES NEW INTERIOR WALLS, DOORS, & FINISHES AS SHOWN ON THE DRAWINGS <br />13. THE SCOPE INCLUDES RE -WORKING THE EXISTING CEILING TO ACCOMMODATE THE NEW WALLS. <br />SHEET NO. TITLE ON SHEET PERMIT SET <br />2011 _09-30 <br />ARCHITECTURAL <br />A000 <br />A100 <br />A101 <br />A102 <br />A103 <br />A901 <br />A902 <br />A903 <br />A904 <br />FIRE SPRINKLER <br />r l <br />�C <br />14. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS, COLUMNS, BEAMS, JOISTS, ROOF <br />DECK, TRUSSES, OR ANY OTHER COMPONENTS OF THE EXISTING STRUCTURAL SYSTEM. THE SCOPE <br />DOES NOT INCLUDE ANY STRUCTURAL WORK ON THE EXISTING WALLS. <br />15. THE SCOPE INCLUDES SAW -CUTTING THE EXISTING FLOOR SLAB AS NEEDED. THE SCOPE INCLUDES <br />RE -POURING ANY PORTION OF THE EXISTING SLAB THAT IS CUT. <br />16. THE EXISTING BUILDING HAS A FIRE SPRINKLER SYSTEM. THE SCOPE INCLUDES REVISING THE <br />EXISTING SYSTEM AS NEEDED TO ACCOMMODATE THE NEW WALLS. THE SCOPE INCLUDES DESIGN <br />AND PERMITTING BY THE FIRE SPRINKLER SUBCONTRACTOR'S SPECIALTY ENGINEER THROUGH HIS 1 <br />HER SHOP DRAWINGS, <br />17. THE SCOPE INCLUDES MODIFYING THE EXISTING PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS. <br />18. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GAS, GREASE, OR STORM. <br />16. THE SCOPE INCLUDES MODIFYING THE EXISTING HVAC SYSTEM AS SHOWN ON THE DRAWINGS. <br />17. THE SCOPE INCLUDES MODIFYING THE EXISTING ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS. <br />18. THE SCOPE INCLUDES MODIFYING THE EXISTING COMMUNICATION / TELEPHONE / DATA SYSTEMS AS <br />SHOWN ON THE DRAWINGS. <br />19. THE EXISTING BUILDING HAS A FIRE ALARM SYSTEM. THE SCOPE INCLUDES MODIFYING THE SYSTEM <br />AS NEEDED FOR THE TENANT BUILD OUT. THE SCOPE INCLUDES DESIGN AND PERMITTING OF THE <br />FIRE ALARM SYSTEM BY THE CONTRACTOR THROUGH SHOP DRAWINGS. <br />Drawing Index <br />COVER SHEET <br />X <br />PROJECT SITE PLAN <br />X <br />PLANS & DETAILS <br />X <br />DETAILS <br />X <br />DETAILS <br />X <br />SPECIFICATIONS <br />X <br />SPECIFICATIONS <br />X <br />SPECIFICATIONS <br />X <br />SPECIFICATIONS <br />X <br />FIRE SPRINKLER NOTE - THE EXISTING SHELL BUILDING IS FULLY SPRINKLERED. THE SPRINKLER SYSTEM SHALL BE MODIFIED AS NEEDED FOR THIS BUILD OUT. ALL MODIFICATIONS TO THE SPRINKLER SYSTEM SHALL <br />BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />PLUMBING _ <br />P101 PLUMBING PLAN & INFORMATION X <br />MECHANICAL <br />M101 MECHANICAL PLAN & INFORMATION X <br />ELECTRICAL <br />E101 ELECTRICAL PLANS & INFORMATION X <br />E501 ELECTRICAL SPECIFICATIONS X <br />FIRE ALARM <br />FIRE ALARM NOTE - THE EXISTING SHELL BUILDING HAS A FULL FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MODIFIED AS NEEDED FOR THIS BUILD OUT. ALL MODIFICATIONS TO THE FIRE <br />ALARM SYSTEM SHALL BE DESIGNED BY THE CONTRACTOR. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS TO THE LOCAL JURISDICTION FOR PERMITTING. <br />� <br />�E <br />N V <br />U <br />�r=4 <br />_- <br />c <br />CD <br />U <br />� <br />CT CD <br />co <br />o <br />LU <br />U <br />Q <br />.0 <br />p <br />C)o <br />w <br />� rn <br />ofCO <br />'o <br />~ <br />CD <br />Vw <br />/, <br />N <br />CD <br />W. <br />,_ <br />�a <br />01 <br />� cn <br />U r <br />mL <br />0 <br />o <br />J a. <br />5 <br />