Laserfiche WebLink
ZEPHYRHILLS, FL <br />STORE NO.: 00706-249 <br />GC2 GARDEN CENTER PLAN AND DETAILS <br />GENERAL <br />Cl COVER SHEET <br />N1 GENERAL INFORMATION <br />SA1 BID ALLOWANCE SCHEDULE <br />LS1 LIFE SAFETY PLAN <br />UlTzlerm IAIx"ILII �1I <br />SP1 <br />SITE PLAN <br />SP2 <br />SITE DETAILS <br />SP3 <br />SITE AND PAVEMENT SIGNAGE DETAILS <br />D1 <br />DEMOLITION PLAN <br />Al <br />FLOOR PLAN <br />A1.1 <br />FLOOR FINISH PLAN <br />A2 <br />EXTERIOR ELEVATIONS <br />A2.1 <br />EXTERIOR DETAILS AND SIGNAGE <br />A2.2 <br />EXTERIOR DETAILS AND SIGNAGE <br />A2.3 <br />EXTERIOR ELEVATION SCOPE <br />A3 <br />SECTIONS AND DETAILS <br />A4 <br />ROOF PLAN AND DETAILS <br />A5 <br />ENLARGED PLANS, ELEVATIONS, AND DETAILS <br />A5.1 <br />RESTROOM PLANS AND DETAILS <br />A5.lA <br />RESTROOM FLOOR FINISH PLAN <br />A5.2 <br />RESTROOM DIMENSIONS AND DETAILS <br />A5.3 <br />RESTROOM ELEVATIONS <br />A5.4 <br />ENLARGED PLANS AND DETAILS <br />A6 <br />REAR OFFICE PLAN <br />A6.1 <br />PARTITION TYPES AND WALL DETAILS <br />A6.2 <br />INTERIOR WALL SECTIONS <br />A8 <br />DOOR AND ROOM FINISH SCHEDULE <br />4V' `4% ADDITION Z:)UlNN 1: <br />EXISTING SOFT: <br />MAJOR PROJECT <br />202 111111 1 <br />P1 <br />OVERALL PLUMBING PLAN <br />A9 <br />CASEWORK <br />P1.1 <br />ENLARGED PLUMBING PLANS <br />AC1 <br />AUTOCENTER PLAN AND DETAILS <br />P2 <br />PLUMBING DETAILS AND SCHEDULES <br />BR1 <br />BREAK ROOM PLAN AND DETAILS <br />BR1.1 <br />BREAKROOM ELEVATION <br />MECHANICAL <br />GC1 <br />GARDEN CENTER PLAN AND DETAILS <br />M1 <br />OVERALL MECHANICAL PLAN <br />RXPFC <br />RXPFC PAINT, FIX CLEAN (PFC) PLAN AND DETAILS <br />M1.1 <br />ENLARGED MECHANICAL PLANS <br />MC1 <br />MONEYCENTER FLOOR PLANS, DETAILS AND SCHEDULES <br />LBPFC <br />LIQUOR BOX PAINT, FIX & CLEAN <br />REFRIGERATION <br />GA1 <br />FRONT GROCERY PLAN <br />BAS2 <br />REFRIGERATION BUILDING AUTOMATION SYSTEM PLANS <br />GA2 <br />REAR GROCERY PLAN <br />BAS3 <br />REFRIGERATION BUILDING AUTOMATION SYSTEM DETAILS <br />GA3 <br />GROCERY DETAILS <br />R1 <br />FRONT REFRIGERATION PLANS <br />GA5 <br />RESPONSIBILITY SCHEDULES <br />R1.1 <br />REAR REFRIGERATION PLAN <br />VC1 <br />VISION CENTER PLANS AND DETAILS <br />R2 <br />REFRIGERATION DETAILS <br />VC1.1 <br />VISION CENTER DETAILS <br />R3 <br />REFRIGERATION SUBMITTALS <br />VC1.2 <br />REFLECTED CEILING PLAN AND DETAILS <br />R3.1 <br />REFRIGERATION SUBMITTALS <br />VC2 <br />VISION CENTER ELEVATIONS <br />VC3 <br />EQUIPMENT (FOR REFERENCE ONLY) <br />ELECTRICAL <br />BAS1 <br />BUILDING AUTOMATION SYSTEM <br />STRUCTURAL <br />E1 <br />LIGHTING PLAN <br />S1 <br />MAIN ID PARAPET EXTENSION <br />Ell <br />ENLARGED LIGHTING PLANS <br />E1.2 <br />ENLARGED LIGHTING PLANS <br />FIRE PROTECTION <br />E1.3 <br />LIGHTING DETAILS AND SCHEDULES <br />FP1 <br />OVERALL FIRE SPRINKLER PLAN <br />E2 <br />POWER PLAN <br />FP2 <br />ENLARGED FIRE SPRINKLER PLAN <br />E2.1 <br />POWER DROP PLAN <br />FP2.1 <br />OPERATIONAL FLEXIBILITY FIRE SPRINKLER PLAN SYSTEM 1 <br />E2.2 <br />ENLARGED POWER PLANS <br />FP2.2 <br />OPERATIONAL FLEXIBILITY FIRE SPRINKLER PLAN SYSTEM 2 <br />E2.3 <br />ENLARGED POWER PLANS <br />FP2.3 <br />OPERATIONAL FLEXIBILITY FIRE SPRINKLER PLAN SYSTEM 3 <br />E3 <br />ELECTRICAL DETAILS <br />FP2.4 <br />OPERATIONAL FLEXIBILITY FIRE SPRINKLER PLAN SYSTEM 4 <br />E4 <br />ELECTRICAL ONE -LINE DETAILS AND SCHEDULES <br />FP2.5 <br />OPERATIONAL FLEXIBILITY FIRE SPRINKLER PLAN SYSTEM 5 <br />E4.1 <br />PANELBOARD SCHEDULES <br />FP3 <br />FIRE PROTECTION DETAILS <br />E4.2 <br />PANELBOARD SCHEDULES <br />E4.3 <br />PANELBOARD SCHEDULES <br />PLUMBING <br />EVC1 <br />VISION CENTER ELECTRICAL PLANS <br />BUILDING CODE SUMMARY <br />NAME OF PROJECT <br />ZEPHYRHILLS, FL <br />STREET ADDRESS <br />7631 GALL BLVD <br />PROPOSED USE <br />MERCANTILE <br />CODES <br />BUILDING CODE <br />FLORIDA BUILDING CODE 6TH EDITION (2017) BUILDING <br />EXISTING BUILDING CODE <br />FLORIDA BUILDING CODE 6TH EDITION (2017) EXISTING BUILDING <br />1 <br />ELECTRICAL CODE <br />FLORIDA BUILDING CODE 6TH EDITION (2017) BUILDING <br />UPDATED EXISITING <br />PLUMBING CODE <br />FLORIDA BUILDING CODE 6TH EDITION (2017) PLUMBING <br />BUILDING CODE <br />MECHANICAL CODE <br />FLORIDA BUILDING CODE 6TH EDITION (2017) MECHANICAL <br />INFORMATION <br />FIRE CODE <br />FLORIDA FIRE PREVENTION CODE 6TH EDITION (2017) <br />ACCESSIBILITY CODE <br />FLORIDA BUILDING CODE 6TH EDITION (2017) ACCESSIBILITY <br />LIFE SAFETY <br />2015 LIFE SAFETY CODE - SIXTH EDITION <br />OCCUPANCY <br />M - MERCANTILE; WHOLESALE OR RETAIL STORE (MAIN USE) <br />- SECT 309.1 <br />S1 -STORAGE AREA; MOTOR VEHICLE STATION AND RECEIVING AND <br />- SECT 311.2 <br />STOCKROOMS (MIXED USE) <br />A2 - ASSEMBLY USE; BREAKROOM AND FOOD TENANT (ACCESSORY TO <br />- SECT 303.1 <br />MAIN USE) <br />B - BUSINESS, NON FOOD TENANT (ACCESSORY TO MAIN USE) <br />- SECT 304.1 <br />TYPE OF CONSTRUCTION <br />II-B UNPROTECTED (SPRINKLERED) <br />PER SECT 602.2 AND TABLES 601 AND 602 <br />ALLOWABLE AREA <br />UNLIMITED <br />SECTION 507.2 SECTION 507.3 <br />FIRE PROTECTION <br />BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER <br />SYSTEM AND IS SURROUNDED ON ALL SIDES BY 60 FEET MINIMUM OF <br />PERMANENT OPEN SPACE. UNLIMITED AREA CRITERIA IS APPLICABLE. <br />CLASSIFICATION OF WORK - <br />LEVEL 2 - ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, <br />(EXISTING BUILDING CODE) <br />THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE <br />RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE <br />INSTALLATION OF ANY ADDITIONAL EQUIPMENT. <br />NOTE: EXISTING SQUARE FOOTAGE, EXISTING <br />PATHS AND EGRESS WIDTH WILL NOT BE <br />IMPACTED BY THE REMODEL SCOPE OF WORK <br />NOTE: BUILDING WILL BE OCCUPIED DURING <br />E <br />CONSTRUCTION, AREAS WILL BE SECTIONED <br />L <br />OFF WITH DUST PARTITIONS OR SECURITY <br />FENCING AS NEEDED. <br />i <br />CN a <br />REF SHEET A2 AND SP1 FOR FUTURE <br />EXPANSION INFORMATION <br />U <br />RE1 <br />REFRIGERATION ELECTRICAL PLAN <br />GE1 <br />GROCERY LIGHTING PLANS <br />GE2 <br />GROCERY POWER PLANS <br />T1 <br />TELECOM PLAN <br />SE1 <br />SITE ELECTRICAL PLAN <br />RACKING <br />FXS1 FIXTURE ANCHORAGE PLAN AND NOTES <br />FXS2 FIXTURE ANCHORAGE DETAILS <br />CIVIL <br />C-302 <br />DETAILED SITE PLAN <br />C-501 <br />UTILITY PLAN <br />SSM-1 <br />STOP SIGNS AND MARKINGS <br />SECP-1 <br />DEMOLITION AND SITE CONSTRUCTION PLAN <br />SECP <br />SSM DETAILS 1 <br />SECP. <br />SSM DETAILS 2 <br />CSS-1 <br />SPECIFICATIONS SHEET <br />CSS-2 <br />SPECIFICATIONS SHEET <br />OGP-C-1 <br />PICKUP 2.0 WAYFINDING SITE PLAN <br />OGP-C-2 <br />PICKUP 2.0 CONSTRUCTION PLAN <br />OGP-C-3 <br />PICKUP 2.0 DETAIL SHEET <br />SPECIAL ELEMENTS <br />OS1 OWNER SUPPLIED ITEMS <br />INTERIOR WALL AND CEILING FINISH <br />REQUIREMENTS BY OCCUPANCY TABLE 803.11 <br />GROUP INTERIOR EXIT STAIRWAY CORRIDORS AND ROOMS AND ENCLOSED <br />AND RAMPS AND EXIT ENCLOSURE FOR EXIT SPACES <br />PASSAGEWAY ACCESS STAIRWAYS AND <br />RAMPS <br />Al & A2 B B C <br />B,E,M,R-1 B C C <br />S B C C <br />CLASS A: FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0-450 <br />CLASS B- FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0-450 <br />CLASS C.- FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450 <br />WINDSPEEDS AND DESIGN <br />NOTICE OF ACCEPTANCE PRESSURES LISTED ON <br />STRUCTURAL DWGS. <br />PRODUCT <br />SUB <br />FLORIDA <br />CATEGORY <br />CATEGORY <br />PRODUCT # <br />PANEL WALLS <br />EIFS <br />FL 2030.14 <br />ROOFING <br />SINGLE <br />FL 1601-R11 <br />PLY ROOF <br />SYSTEMS <br />FLORIDA PRODUCT NOA # NOA <br />EXPIRATION DATE EXPIRATION DATE <br />DECEMBER 20, 2021 17-0807.16 DECEMBER 20, 2021 <br />DECEMBER 14, 2021 20.0310.08 MAY 05, 2023 <br />PROTO CYCLE: <br />DATE: <br />PROTO: <br />PROJECT <br />SITE <br />6 <br />SHEET ADDED IN CCD#5: <br />• SE1 SITE ELECTRICAL PLAN <br />5 <br />SHEETS ADDED IN CCD#4: <br />• C-302 DETAILED SITE PLAN <br />• C-501 UTILITY PLAN <br />rDURING <br />CCD1 THE FOLLOWING SHEET <br />DDED: <br />.1 REFRIGERATION SUBMITTALS <br />2 <br />HEALTH AND WELLNESS <br />CIVIL (FOR REFERENCE <br />ONLY PERMIT SPR-0011-20 <br />=ADDED <br />: <br />R PLANS AND <br />VICINITY MAP <br />GENERAL <br />SCOPE OF WORK <br />• EXTERIOR SURFACES: CLEAN, PREP AND PAINT <br />• INTERIOR WALLS: CLEAN, PREP AND PAINT <br />• PHARMACY: PAINT AND CLEAN AS NOTED <br />• REFURBISH CUSTOMER RESTROOMS AS NOTED <br />• BREAK ROOM: REVISED AS SHOWN. <br />• CUSTOMER SERVICE: REVISED AS SHOWN. <br />• ENTRY VESTIBULE: CLEAN, LIGHTING AND PAINT <br />• AUTO CENTER: REVISED AS NOTED <br />• MONEYCENTER: REVISED AS SHOWN. <br />I_�Qu48 NEVI �Q as SHP-WN,. <br />• PICKUP, INTERIOR: REVISED AS SHOWN. <br />• PICKUP, EXTERIOR: REVISED AS SHOWN - <br />TENANT <br />• TENANT SPACE: REVISED AS SHOWN. <br />• INSTALL NEW VISION CENTER AS SHOWN. <br />14)000 <br />2051831 <br />09/25/20 <br />11/06/20 <br />192NEM SPBR <br />SHEETS ADDED IN ADD1: <br />• A2.2 EXTERIOR ELEVATION SCOPE <br />• A5.4 ENLARGED PLANS AND DETAILS <br />A2.2 EEXTERIOR DETAILS AND SIGNAGE <br />A2.3 EXTERIOR ELEVATION SCOPE <br />• BR1.1 BREAKROOM ELEVATION <br />• GA5 RESPONSIBILITY SCHEDULES <br />• RXPFC PAINT FIX CLEAN (PFC) PLAN AND DETAILS <br />VC1 VISION CENTER PLANS AND DETAILS <br />• VC1.1 VISION CENTER DETAILS <br />• VC1.2 REFLECTED CEILING PLAN AND DETAILS <br />• VC2 VISION CENTER ELEVATIONS <br />• VC3 EQUIPMENT (FOR REFERENCE ONLY) <br />• M1.1 ENLARGED MECHANICAL PLANS <br />E2.1 POWER DROP PLAN <br />E2.3 ENLARGED POWER PLANS <br />E4.2 PANELBOARD SCHEDULES <br />EVC1 VISION CENTER ELECTRICAL PLANS <br />RE1 REFRIGERATION ELECTRICAL PLAN <br />GE2 GROCERY POWER PLAN <br />SHEETS REMOVED IN ADD1: <br />• TPH1 TEMPORARY PHARMACY <br />• PH1 PHARMACY PLANS AND ELEVATIONS <br />PH1.1 PHARMACY DETAILS <br />PH2 PHARMACY ELEVATIONS <br />PH2.1 PHARMACY ELEVATIONS <br />PH3 EQUIPMENT PLAN AND ELEVATIONS (FOR <br />REFERENCE ONLY) <br />• TPH1 TEMPORARY PHARMACY PLUMBING PLANS <br />• EPH1 PHARMACY ELECTRICAL PLAN <br />ALL REFRIGERATION, CIVIL, AND RACKING DRAWINGS HAVE <br />BEEN ADDED TO THE CONSTRUCTION SET OF DOCUMENTS <br />GENERAL NOTES <br />1. BUILDING WILL BE FULLY SPRINKLERED AS <br />REQUIRED BY CONTRACT DOCUMENTS. SUBMIT FIRE <br />SPRINKLER SYSTEM DRAWINGS AND CALCULATIONS <br />TO AUTHORITIES HAVING JURISDICTION (FIRE <br />DEPARTMENT, FIRE MARSHAL, ETC). OBTAIN ALL <br />APPROVALS PRIOR TO FABRICATION OR <br />INSTALLATION. <br />2, OWNER WILL PROVIDE, OR HAS ALREADY PROVIDED, <br />FIRE EXTINGUISHERS IN ACCORDANCE WITH NFPA <br />10. AUTHORITY HAVING JURISDICTION WILL <br />APPROVE FINAL FIRE EXTINGUISHER LOCATIONS. <br />3. WAL-MART'S ALARM CENTRALS ENGINEERING TEAM <br />HAS CONTACTED THE AUTHORITY HAVING <br />JURISDICTION FOR PRE -PLAN DATA ABOUT STATE <br />AND LOCAL REQUIREMENTS THAT DIFFER FROM THE <br />NATIONALLY PUBLISHED CODES AND STANDARDS. A <br />COMPLETE SITE SPECIFIC SUBMITTAL IS BEING <br />MADE DIRECTLY TO THE AUTHORITY HAVING <br />JURISDICTION. QUESTIONS SHOULD BE DIRECTED <br />TO 1-800-530-9924, OPTION 3. <br />4. THE MAXIMUM STORAGE HEIGHT IS TWELVE FEET <br />EXCEPT IN THE GENERAL MERCHANDISE RECEIVING <br />AREA IMMEDIATELY ADJACENT TO THE DOCK <br />DOORS. THE STOCKROOM WILL HAVE A STACKING <br />HEIGHT OF 15 FEET OF CLASS I -IV COMMODITIES IN <br />FIXED, SINGLE AND DOUBLE ROW RACKS. THE <br />STACKING HEIGHT OF THE ROLLING RACK AREA WILL <br />NOT EXCEED 12 FEET. <br />5. REFER TO SPECIFICATION SECTIONS 01600 - <br />PRODUCT REQUIREMENTS AND APPENDIX A - <br />PRODUCTS AND WORK BY OWNER OR SEPARATE <br />CONTRACTOR. THESE SECTIONS INCLUDE SPECIFIC <br />INFORMATION REGARDING ITEMS AND SERVICES TO <br />BE FURNISHED AND INSTALLED BY INDIVIDUALS <br />OTHER THAN THE GENERAL CONTRACTOR. <br />6. REINSTALL ALL FIRE EXTINGUISHERS IMMEDIATELY <br />FOLLOWING COMPLETION OF FINAL FINISH TO <br />MOUNTING SURFACE <br />7. REFER TO GENERAL CONTRACTOR PERMIT, <br />REGISTRATION, NOTIFICATION INSPECTION & <br />INSTALLER CERTIFICATION(GCPRN) REPORT <br />LOCATED IN GC PERMIT INFORMATION FOLDER ON <br />OWNER'S DOCUMENT DELIVERY WEBSITE. <br />11 <br />is <br />is <br />a cro <br />w w Z W K O > <br />Lu <br />Cn <br />�a ��a=�� <br />0-- a w H w <br />O <br />W <br />o f O a a> w O Q <br />a a~ w O Z O w S O a w <br />O <br />w- w O H Z� a <br />���anaa=a-on <br />LL <br />dace-l-��~❑0wH= <br />Z <br />O <br />a_�O�w�XW.0 <br />nQNZO <br />UoO�~ <br />ZE d- OOUOQ <br />�w?uZ�.UWcZn0 <br />n-0 <br />3U0oUxw <br />doUH <br />C(0wcl <br />- �wl <br />000<ou�aZO <br />mawww�d <br />=zZ,-L <br />z <br />Q <br />H <br />J <br />U) <br />z <br />O <br />U <br />00 <br />L04 <br />O O�� <br />O o <br />1 L <br />LL <br />�cf) <br />CnJ O' <br />J� <br />o <br />a <br />i <br />� O <br />fV O <br />M <br />o <br />`} <br />/ <br />Z <br />0 LLI <br />tY <br />N <br />N <br />0 <br />^=m0 <br />w� <br />N <br />co <br />ti <br />w <br />m <br />z <br />m <br />O <br />ISSUE BLOCK <br />1 <br />ADD1 <br />01/27/21 <br />2 <br />ADD3 <br />02/26/21 <br />3 <br />CCD1 <br />03/29/21 <br />4 <br />CCD3 <br />05/11/21 <br />5 <br />CCD4 <br />06/21/21 <br />6 <br />CCD5 <br />08/16/21 <br />CHECKED BY: <br />RD <br />DRAWN BY' <br />AJB <br />PROTO CYCLE: <br />09/25/20 <br />DOCUMENT DATE: <br />11/06/20 <br />COVER <br />SHEET <br />ARCHITECTURAL <br />Q 0 <br />2 CUHACI & PETERSON LLC <br />N ROBERT DAY <br />g 2-660 `MAI'rLAKb-ffNrtR`_P <br />o y AITLA �,�_QR�A,3,�7�51, <br />3 407-661-9100 <br />m 6 <br />STRUCTURAL I FIRE PROTECTION I MECHANICAL I REFRIGERATION <br />JOHNSTON BURKHOLDER ASSOCIATES <br />I CUHACI & PETERSON LLC <br />CUHACI & PETERSON LLC <br />HENDERSON ENGINEERS <br />JASON HENDRIX <br />4NpRE\N\/4L_E ATE-, . _ ,. <br />qSE J_ DIAZ _-, <br />TREVOR G. JONES,ti- <br />930 CENTRAL <br />2600 MAITLAND CENTER PKWY #200 <br />2600 MAITLAND CENTER PKWY #200 <br />8345 LENEXA DRIVE, SUITE 300 <br />KANSAS CITY, MISSOURI 64105 <br />AITLAND.F.-LQRIAB,.327 <br />T_LAND F 1 <br />LENEXA, KANSAS 66214,E ,` <br />816-421-4200 <br />407-661-9100 <br />407-661-9100 <br />913-742-5001 <br />ELECTRICAL RACKING CIVIL <br />CUHACI & PETERSON LLC JOHNSTON BURKHOLDER ASSOCIATES BOHLER <br />JAISON P MORASS BART J. HALVERSON RYAN HILEMEN, PE. PMP. <br />2600 MAITLAND CENTER PKWY #200 930 CENTRAL 255 GLADES ROAD, SUITE 305E <br />M IT A D F R D 3 7 1 KANSAS CITY, MISSOURI 64105 BOCA RATON, FLORIDA 33431 <br />407-661-9100 816-421-4200 561-571-0280 <br />BUILDING OFFICIAL <br />CITY OF ZEPHYRHILLS <br />BILL BURGESS <br />5335 8TH STREET <br />ZEPHYRHILLS, FLORIDA 33542 <br />813-780-0020 <br />SHEET: <br />c 1 <br />