My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 GALL BLVD (51)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 GALL BLVD (51)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 2:13:08 PM
Creation date
4/12/2017 2:06:39 PM
Metadata
Fields
Template:
Building Plans
Street #
7050 GALL BLVD
Location
GALL BLVD
Description
OUTPATIENT SURGERY
Owner
EAST PASCO MEDICAL CENTER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; <br /> � I <br /> � I <br /> i <br /> Don ',Edge -2- ; April 6, 1995 <br /> � <br /> RESPONSE^ ; <br /> �, j <br /> We shall comply, NFPA 70, Article � 680-6 (b) (1) <br /> (exception 2) allows lighting above indoor swimming pools <br /> if they meet the following criteria: <br /> �I 1. The fixtures are of the totally, enclosed type. <br /> Please refer to the attached fixture cuts for <br /> compliance. � <br /> 2. A GFCI is installed in the branch circuit supplying <br /> � the fixtures. Please refer to the attached revised <br /> Sheet E-12, dated April 6, 1995, Star #9, Panel <br /> Circuit Number 1HN1-41 for complia�nce. <br /> 3. The distance from the bottom of the fixture to the <br /> maximum water level is not less than 7'-6" . The <br /> � fixtures are pendant mounted on a ceiling that is <br /> i 9'-6" below the slab. The pendant mounted fixtures <br /> hang 2' below the ceiling or 7'-6" AFF and 8' above <br /> the water to the bottom of the fix�ture. <br /> COMMENT• � <br /> -37j Provide ground fault circuit interrupter for all ; <br /> electrically operated therapeutic equipment. The carpet � <br /> j roller motor shall be located a minimum of 5 feet from <br /> the inside edge of the pool in accordan�ce with NFPA-70, <br /> Article 680-26. , <br /> ; <br /> SP�ONSE• � <br /> We shall comply, please refer to the revised drawing ; <br /> Sheet E-6, dated April 6, 1995, Star #9 attached for <br /> compliance. All whirlpools presently a�re designed with <br /> , SFCI outlets for motor connections, refer to Sheet E-6. � <br /> � <br /> COMMENT• i ' <br /> E-38 The pool lift motor shall be connected to equipment '�� � <br /> � branch to ensure the ability for patien�t removal in the ' <br /> I event of normal power loss. , ' <br /> RESPONSE• <br /> , We shall comply, please refer to the revised drawings ' i <br /> I Sheet E-3 and E-12, dated April 6, 1995, Star #9 attached i <br /> �� for compliance. ; <br /> , <br /> � <br /> � , <br /> I I I �, <br /> ' I <br /> � � I � <br /> � ; ' I <br /> , � <br />
The URL can be used to link to this page
Your browser does not support the video tag.