My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 GALL BLVD (53)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 GALL BLVD (53)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 2:37:28 PM
Creation date
4/12/2017 2:28:06 PM
Metadata
Fields
Template:
Building Plans
Street #
7050 GALL BLVD
Location
GALL BLVD
Description
SOUTH ADDITION
Owner
EAST PASCO MEDICAL CENTER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; <br /> .= . , . <br /> !�age 4 <br /> ::�eptember 6, 1994 <br /> 1-ir. James R. Gregory � <br /> i <br /> � ' ' <br /> I <br /> Comment: A-23 Sheet A5-12: � <br /> ; A. Section 4: The separation wall between Mechanical <br /> i Room 401 and the atrium shall be a 1-hour listed <br /> � � assembly from the floor-to-roof deck above per the <br /> ' AHCA letter of January 3, 1994. The store front and <br /> � water curtain are not approved. Revise accordingly. <br /> � <br /> ' B. Coordinate this section with the exhaust system <br /> � indicated on Sheet M-18. <br /> Response: A 1-hour rated wall now separates the (created) Vestibule <br /> 401 from Mechanical Room 402 isolating the Mechanical space <br /> from the Atrium with space 401. Vestibule 401, being roof <br /> only accessible, empty and non-hazardous should allow us to <br /> return to the wetted (water curtain) storefront at this <br /> Fourth Level. See revised drawing A2-12, addendum #2, dated <br /> 9/6/94. <br /> New Comment: A-24 Sheet A6-4: <br /> I ' <br /> A. Revise Details 3, 6-10 to comply with the glazing <br /> requirement of NFPA-101 that all glass in the atrium <br /> separation walls be wired, tempered or laminated, set <br /> in gaskets to prevent breaking under heat stress. <br /> B. Details 8-10 show wood blocking that is not fire <br /> retardant treated within the building envelope, revise <br /> to comply. <br /> Response: Details 3 and 6-10 have been revised, likewise details 8-10 - <br /> have been revised to show fire retardant treated wood , <br /> ; blocking. (Al1 wood blocking throughout the building has I <br /> � long been specified to be fire treated. ) See revised Sheet � <br /> , A6-4, Addendum #2, dated 9/6/94. � <br /> ,�• Very t L��tly y ouurs, <br /> - .= �'-�%� _ ' i <br /> .. z���'�� �= <br /> ,-, Donald .R. Edg.e <br /> � �Architect : ' � <br /> Enclosurec Addendum #2 <br /> � Peninsula Response ; <br /> cc: East �Pasco Medical Center <br /> Penirisula Engineering ; <br /> c:xin\0661.94 , <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.