My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19692
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19692
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 10:09:40 AM
Creation date
2/7/2019 10:09:38 AM
Metadata
Fields
Template:
Building Department
Company Name
SUNSET ESTATES
Building Department - Doc Type
Permit
Permit #
18-19692
Building Department - Name
ROBERTS,JASON & MELISSA
Address
39307 8TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PTRINITY�ERD <br /> 6.6.4 For non-tile roof installations: <br /> 6.6.4.1 Standard Installation with Single Layer; roof slope > 4:12 <br /> Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the <br /> field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. <br /> Continue upslope in a similar manner,'maintaining minimum 3-inch side-laps and minimum <br /> 6-inch end-laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, <br /> staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. <br /> 6.6.4.2 Standard Installation with Double Layer; 2:12 < roof slope < 4:12 <br /> Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the <br /> field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. <br /> Continue upslope in a similar manner, with minimum 22.5-inch side-laps and minimum 6- <br /> inch end-laps. Fasten 6-inch o.c. along the low edge and end laps and 12-inch o.c. in two, <br /> equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least <br /> 3-feet apart. <br /> 6.7 StorrnSafeM Anchor Sheet: <br /> 6.7.1 StormSafe@ Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply <br /> underlayment systems. <br /> 6.7.2 Fasteners shall be 1-inch diameter plastic- or steel-capped corrosion resistant nails; <br /> corrosion-resistant nails & 1-5/8-inch tin-caps; or Drill-Tec screws and plates. <br /> 6.7.3 For non-tile roof installations: <br /> Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the <br /> field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. <br /> Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum <br /> 6-inch end-laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, <br /> staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. <br /> One the same day, install LibertyT'" SBS Self-Adhering Base/Ply; Ruberoid@ SA Base/Ply; <br /> StormGuard@; UnderRooFm 2; UnderRooFm HT; Weather Watch@ or Weather Watch @ XT <br /> over the StormSafe@ Anchor Sheet. <br /> 6.8 RoofProTM SBS-Modified All-Purpose Underlavment and Shingle-MateTm Roof Deck <br /> Protection <br /> 6.8.1 Install RoofProTm and Shingle-MatT°^ in compliance with manufacturer's published installation <br /> instructions and the requirements for ASTM D226, Type I and II underlayments in FBC <br /> Sections 1507 for the type of prepared roof covering to be installed. A double layer is <br /> required for 2:12 < roof.slope < 4:12. No hammer tacks or staples are permitted. <br /> 6.8.2 Install a leak barrier of LibertyTM SBS Self-Adhering Base/Ply Sheet; Ruberoid@ SA Base/Ply <br /> Sheet; StormGuard@; UnderRoof"m 2; UnderRoofT"' HT; Weather Watch@ or Weather <br /> Watch@ XT at vulnerable leak areas, including but not limited to eaves, valleys, rakes, <br /> skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of <br /> RoofProTM or Shingle-Mate TM. Along the rake, install RoofProTM or Shingle-Mate TM, leaving 6 <br /> to 8-inch of the deck exposed, and then install the leak barrier over the RoofProTM or Shingle- <br /> MateT" and exposed decking. At other areas, install the leak barrier over the RoofProTM or <br /> Shingle-Mate TM. <br /> 1 <br /> 1 <br /> Exterior Research and Design, LLC. Evaluation Report 01506.04.08-R5 <br /> Certificate ofAuthorization#9503 FL10626-R5 <br /> Revision 5: 11/02/2011 <br /> Page 7 of 11 <br />
The URL can be used to link to this page