Laserfiche WebLink
TRINITY 1 M <br /> Use a hand roller to firmly bond side and end laps. <br /> 6.12.5 For non-tile applications, to mechanically attached anchor sheet: <br /> Install ASTM D226, Type II felt in accordance with-codified requirements or StormSafe@ <br /> Anchor Sheet in accordance with Section 6.6. <br /> Install UnderRoofTm 2 Leak Barrier over the mechanically attached anchor sheet as noted <br /> above. <br /> 6.13 UnderRoof m HT Leak Barrier: <br /> 6.13.1 Install UnderRoofrm HT Leak Barrier in compliance with manufacturer's published installation <br /> instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for <br /> the type of prepared roof covering to be installed. <br /> 6.13.2 The minimum and maximum roof slopes are 1:12 and 12:12, respectively. Back-nailing is <br /> required when slope is 4:12 or greater. Back-nailing shall consist of minimum 1-inch square <br /> or round cap nails spaced 12"o.c. within 4-inch side laps. <br /> 6.13.3 For non-tile applications, direct to deck: <br /> Prior to removal of release film, align sheets properly starting 'at the low-point of the roof <br /> (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. <br /> Remove the lower piece of release film and bond to substrate and fold the overhanging 2- <br /> inch over the eave and nail into place 12" o.c. Remove the top piece of release film and <br /> bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load <br /> requirements. Install 1/8-inch troweling of TopCoat@ FlexSealTM Caulk Grade over drip <br /> edge. <br /> Continue upslope in a similar manner, maintaining minimum 4-inch side-laps and minimum <br /> 6-inch end-laps. Ensure all end laps are staggered at least 3-feet apart. <br /> Use a hand roller to firmly bond side and end laps. <br /> 6.13.4 For non-tile applications, to mechanically attached anchor sheet: <br /> Install ASTM D226, Type II felt in accordance with codified, requirements or StormSafe@ <br /> Anchor Sheet in accordance with Section 6.7. <br /> Install UnderRooF" HT Leak Barrier over the mechanically attached anchor sheet as noted <br /> above. <br /> 6.14 Weather WatchO or Weather Watch(D XT Leak Barrier: <br /> 6.14.1 Install Weather Watch@ or Weather Watch@ XT Leak Barrier in compliance with <br /> manufacturer's published installation instructions and the requirements for ASTM D1970 <br /> underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. <br /> 6.14.2 Weather Watch@ Leak Barrier may be installed as a secondary water barrier using minimum <br /> 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment <br /> system. <br /> 6.14.3 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap <br /> nails spaced 18"o.c. within 4-inch side laps. <br /> 6.14.4 For non-tile applications, direct to deck: <br /> Prior to removal of release film, align sheets properly starting at the low-point of the roof <br /> (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. <br /> Remove the lower piece of release film and bond to substrate and fold the overhanging 2- <br /> inch over the eave and nail into place 12" o.c. Remove the top piece of release film and <br /> bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load <br /> requirements. Install 1/8-inch troweling of TopCoat@ MatrixTm 201 Premium SBS Flashing <br /> Exterior Research and Design, LLC. Evaluation Report 01506.04.08-R5 <br /> Certificate of Authorization#9503 FL10626-R5 <br /> Revision 5: 11/02/2011 <br /> Page 10 of 11 <br />