My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20581
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20581
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:23:09 AM
Creation date
1/13/2020 1:52:57 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR II LLC
Building Department - Doc Type
Permit
Permit #
18-20581
Building Department - Name
PIZZA HUT
Address
5897 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7d Mechanical Heat Rejection Equipment:Minimum Efficiency <br /> Requirement Table 6.8.1-7 <br /> SYSTEM—SPECIFIC 6.5.5.3 Mechanical Centrifugal fan open-circuit cooling towers having <br /> combined rated capacity>=1100 gpm meets <br /> minimum efficiency requirement:Table 6.8.1-7 <br /> SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7e Mechanical Heat Rejection Equipment:Minimum Efficiency <br /> Requirement Table 6.8.1-7 <br /> SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7f Mechanical Heat Rejection Equipment:Minimum Efficiency <br /> Requirement Table 6.8.1-7 <br /> SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7g Mechanical Heat Rejection Equipment:Minimum Efficiency <br /> Requirement Table 6.8.1-7. <br /> SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7h Mechanical Heat Rejection Equipment:Minimum Efficiency <br /> Requirement Table 6.8.1-7 <br /> SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7i Mechanical Heat Rejection Equipment:Minimum Efficiency <br /> Requirement Table 6.8.1-7 <br /> SYSTEM—SPECIFIC 7.5.3 Mechanical Gas-fired water-heating equipment installed in <br /> new buildings:where a singular piece of <br /> water-heating equipment>=1,000 kBtu/h serves <br /> the entire building,thermal efficiency must be>_ <br /> 90 Et. <br /> Where multiple pieces of water-heating <br /> equipment serve the building with combined rating <br /> is>=1,000 kBtu/h,the combined <br /> input-capacity-weighted-average"thermal <br /> efficiency,thermal efficiency must be>=90 Et <br /> Exclude input rating of equipment in individual <br /> dwelling units and equipment<=100 kBtu/h. <br /> 2.,To be checked by Plan Reviewer <br /> Plan Review 4.2.2,5.4.3.1.1,5.7 Envelope Plans and/or specifications provide all information <br /> with which compliance can be determined for the <br /> building envelope and document where <br /> exceptions to the standard are claimed. <br /> Plan Review 4.2.2,6.4.4.2.1, Mechanical Plans,specifications,and/or calculations provide <br /> 6.7.2 all information with which compliance can be <br /> determined for the mechanical systems and <br /> equipment and document where exceptions to the <br /> standard are claimed. Load calculations per <br /> acceptable engineering standards and <br /> handbooks. <br /> Plan Review 4.2.2,7.7.1,10.4.2 Mechanical Plans,specifications,and/or calculations provide <br /> all Information with which compliance can be <br /> determined for the service water heating systems <br /> and equipment and document where exceptions <br /> to the standard are claimed. Hot water system <br /> sized per manufacturer's sizing guide. <br /> Plan Review 4.2.2,8.4.1.1, Project Plans,specifications,and/or calculations provide <br /> 8.4.1.2,8.7 all information with which compliance can be <br /> determined for the electrical systems and <br /> equipment and document where exceptions are <br /> claimed.Feeder connectors sized in accordance <br /> with approved plans and branch circuits sized for <br /> maximum drop of 3%. <br /> Plan Review 4.2.2,9.4.3,9.7 Interior Lighting Plans,specifications,and/or calculations provide <br /> all information with which compliance can be <br /> determined for the interior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided should include interior <br /> lighting power calculations,wattage of bulbs and <br /> ballasts,transformers and control devices. <br /> Plan Review 9.7 Exterior Lighting Plans,specifications,and/or calculations provide <br /> all information with which compliance can be <br /> determined for the exterior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided should include exterior <br /> lighting power calculations,wattage of bulbs and . <br /> ballasts,transformers and control devices. <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option <br /> 7/6/2018 Page 9 of 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.