My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20581
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20581
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:23:09 AM
Creation date
1/13/2020 1:52:57 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR II LLC
Building Department - Doc Type
Permit
Permit #
18-20581
Building Department - Name
PIZZA HUT
Address
5897 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has<=0.3% <br /> water absorption rate perASTM C272. <br /> Air Leakage 5.4.3.4 Envelope Vestibules are installed where building entrances <br /> separate conditioned space from the exterior,and <br /> meet exterior envelope requirements. Doors have <br /> self-closing devices,and are>=7 ft apart(>=16 ft <br /> apart for adjoinging floor area>=40000 sq.ft.). <br /> Vestibule floor area<=7 50 sq.ft.or 2 percent of <br /> the adjoining conditioned floor area. <br /> HVAC 6.4.3A.4 Mechanical Ventilation fans>0.75 hp have automatic controls <br /> to shut off fan when not required. <br /> HVAC 6.4.3.8 Mechanical Demand control ventilation provided for spaces 1-1 El <br /> >500 ft2 and>25 people/1000 ft2 occupant <br /> density and served by systems with air side <br /> economizer,auto modulating outside air damper <br /> control,or design airflow>3,000 cfm. <br /> HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible <br /> heating panels have insulation>=R-3.5. <br /> HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent 1:11:1 El <br /> reheating,recooling,mixing of hot and cold <br /> airstreams or concurrent heating and cooling of <br /> the same airstream. <br /> SYSTEM—SPECIFIC 6.5.3.1.3 Mechanical Fans have efficiency grade(FEG)>=67.The total ❑ ❑ <br /> El <br /> efficiency of the fan at the design point of <br /> operation<=15%of maximum total efficiency of <br /> the fan. <br /> SYSTEM—SPECIFIC 6.5.3.5 Mechanical Motors for fans>=1/12 hp and<1 hp are <br /> electronically-commutated motors or have a <br /> minimum motor efficiency of 70%.These motors <br /> are also speed adjustable for either balancing or <br /> remote control. <br /> SYSTEM—SPECIFIC 6.4.3.10 Mechanical DDC system installed and capable of providing <br /> control logic including monitoring zone and <br /> system demand for fan pressure,pump pressure, <br /> heating,and cooling;transferring zone and <br /> system demand information from zones to air <br /> distribution system controllers and from air <br /> distribution systems to heating and cooling plant <br /> controllers;automatically detecting and alerting <br /> system operator when zones and systems <br /> excessively drive the reset logic;allow operator <br /> removal of zone(s)from the reset algorithm;AND <br /> capable of trending and graphically displaying <br /> input and output points. <br /> SYSTEM—SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DDC controlled <br /> VAV boxes reporting to central controller based on <br /> the zones requiring the most pressure.Controls <br /> provide:zone damper monitoring or indicator of <br /> static pressure need;autodetection,alarm,and <br /> operator override of zones excessively triggering <br /> reset logic. <br /> SYSTEM—SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DDC of individual 1:111 El <br /> zone boxes have static pressure setpoint reset <br /> controls. <br /> SYSTEM—SPECIFIC 6.5.3A Mechanical Multiple zone HVAC systems have supply air <br /> temperature reset controls. " <br /> SYSTEM—SPECIFIC 6.5.4.1 Mechanical System turndown requirement met through <br /> multiple single-input boilers,one or more <br /> modulating boilers,or a combination of <br /> single-input and modulating boilers. <br /> Boiler input between 1.0 MBtu/h and 5 MBtu/h <br /> has 3:1 turndown ratio,boiler input between 5.0 <br /> MBtu/h and 10 MBtu/h has 4:1 turndown ratio, <br /> boiler input>10.0 MBtu/h has 5:1 turndown ratio. <br /> HVAC 6.5.4.2 Mechanical HVAC pumping systems>10 hp designed for <br /> variable fluid flow. <br /> SYSTEM—SPECIFIC 6.5.4.3,6.5.4.3.1, Mechanical Fluid flow shutdown in pumping systems to 1-1 ❑ <br /> 6.5.4.3.2 multiple chillers or boilers when systems are shut <br /> down. <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software. Effective Date:Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option <br /> 7/6/2018 Page 10 of 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.