My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20581
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20581
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:23:09 AM
Creation date
1/13/2020 1:52:57 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR II LLC
Building Department - Doc Type
Permit
Permit #
18-20581
Building Department - Name
PIZZA HUT
Address
5897 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM—SPECIFIC 6.5.4.4 Mechanical Temperature reset by representative building <br /> loads in pumping systems>10 hp for chiller and <br /> boiler systems>300,000 Btu/h. <br /> SYSTEM—SPECIFIC 6.5.4.5.2 Mechanical Hydronic heat pumps and water-cooled unitary air 0 El <br /> conditioners with pump systems>5 hp have <br /> controls or devices to reduce pump motor <br /> demand. <br /> SYSTEM—SPECIFIC 6.5.4.6 Mechanical . Chilled-water and condenser water piping sized El ED 11 <br /> according to design flow rate and total annual <br /> hours of operation(Table 6.5.4.6). <br /> SYSTEM—SPECIFIC 6.5.5.2.1 Mechanical Fan systems with motors>=7.5 hp associated <br /> with heat rejection equipment to have capability to <br /> operate at 213 of full-speed and auto speed <br /> controls to control the leaving fluid temperature or <br /> condensing temp/pressure of heat rejection <br /> device. <br /> SYSTEM—SPECIFIC 6.5.5.2.2 Mechanical Multicell heat rejection equipment with <br /> variable-speed fan drives installed that operate <br /> the maximum number of fans allowed that comply <br /> with manufacturers specs and control all fans to <br /> the same fan speed required for the <br /> instantaneous cooling duty. <br /> SYSTEM—SPECIFIC 6.5.5.2.3 Mechanical NA <br /> HVAC 6.5.7.1.1 Mechanical Ktchen hoods>5,000 cfm have make up air 1:1 El El <br /> >=50%of exhaust air volume. <br /> HVAC 6.5.7.1.1 Mechanical Kitchen hoods>5,000 cfm have make up air <br /> >=50%of exhaust air volume. <br /> SYSTEM—SPECIFIC 6.5.7.1.2 Mechanical Conditioned supply air to space with a kitchen <br /> hood shall not exceed the greater of a)supply <br /> flow required to meet space heating or cooling,or <br /> b)hood exhaust flow minus the available air <br /> transfer from available spaces. <br /> SYSTEM—SPECIFIC 6.5.7.1.3 Mechanical Kitchen hoods with a total exhaust airflow rate <br /> >5000 cfm meet replacement air,ventilation <br /> system,or energy recovery requirements shown <br /> in Table 6.5.7.1.3. <br /> SYSTEM—SPECIFIC 6.5.7.1.4 Mechanical Kitchen hoods with a total exhaust airflow,rate <br /> >5000 cfm meet replacement air,ventilation <br /> system,or energy recovery requirements. <br /> HVAC 6.5.7.2 Mechanical Fume hoods exhaust systems>=5,000 cfm have <br /> VAV hood exhaust and supply systems,direct <br /> make-up air or heat recovery. <br /> HVAC 6.5.8.1 Mechanical Unendosed spaces that are heated use only El El 0 <br /> radiant heat. <br /> SYSTEM—SPECIFIC 7.5.1 Mechanical Combined space and water heating system not 11 El El <br /> allowed unless standby loss less than calculated <br /> maximum.AHJ has approved or combined <br /> connected load<150 kBtu/h. <br /> Controls 8.4.2 Project At least 50%of all 125 volt 15-and 20-Amp El El El <br /> receptacles are controlled by an automatic control <br /> device. <br /> Other Equipment 10.4.1 Mechanical Electric motors meet requirements where 1:1 El El <br /> applicable. <br /> HVAC 6.4.3.3.2 Mechanical Setback controls allow automatic restart and 11 El El <br /> temporary operation as required for maintenance. <br /> SYSTEM—SPECIFIC 6.4.3.3.3 Mechanical Systems with setback controls and DDC include <br /> optimum start controls.Optimum start algorithm <br /> considers mass radiant slab floor temperature. <br /> SYSTEM—SPECIFIC 6.4.3.3.4 Mechanical Zone isolation devices and controls. 1:1 0 <br /> Wattage 9.4.2 Exterior Lighting Exterior lighting power is consistent with what is <br /> shown on the approved lighting plans, <br /> demonstrating proposed watts are less than or <br /> equal to allowed watts. <br /> 3To be checked by lnspector . <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation ASHRAE 90.1-2013-Prescriptive Compliance Option <br /> 7/6/2018 Page 11 of 21 <br />