My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20581
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20581
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:23:09 AM
Creation date
1/13/2020 1:52:57 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR II LLC
Building Department - Doc Type
Permit
Permit #
18-20581
Building Department - Name
PIZZA HUT
Address
5897 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Insulation 5.8.1.7 Envelope Exterior insulation protected against damage, <br /> sunlight,moisture,wind,landscaping and <br /> equipment maintenance activities. <br /> HVAC 6.4.3.7 Mechanical Freeze protection and snow/ice melting system <br /> sensors for future connection to controls. <br /> Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped,sealed, ❑ <br /> caulked,gasketed,and/or taped in an approved <br /> manner,except in semiheated spaces in climate <br /> zones 1-6. <br /> Air Leakage 5.4.3.2 Envelope Factory built and site-assembled fenestration and E _ <br /> doors are labeled or certified as meeting air <br /> leakage requirements. <br /> Fenestration 5.8.2.1,5.8.2.3. Envelope Fenestration products rated(U-factor,SHGC,and <br /> 5.8.2.4,5.8.2.5 VT)in accordance with NFRC or energy code <br /> defaults are used. <br /> Fenestration 5.8.2.2 Envelope Fenestration and door products are labeled,or a <br /> signed and dated certificate listing the U-factor, <br /> SHGC,VT,and air leakage rate has been <br /> provided by the manufacturer. -10 El <br /> SYSTEM—SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water ' <br /> heating systems(<=120A°F to maximum <br /> temperature for intended use). <br /> SYSTEM—SPECIFIC 7.4.4.2 Mechanical Automatic time switches installed to automatically 1:1 El <br /> switch off the recirculating hot-water system or <br /> heat trace. <br /> SYSTEM—SPECIFIC 7.4.6 Mechanical Heat traps installed on non-circulating storage El El El <br /> water tanks. <br /> HVAC 6.4.1.4,6.4.1.5 Mechanical HVAC equipment efficiency verified.Non-NAECA El El El <br /> HVAC equipment labeled as meeting 90.1. <br /> SYSTEM—SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in.by 42 in. <br /> labeled for replacement only. <br /> HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized El El ❑ <br /> dampers that automatically close. <br /> HVAC 6.4.3.4.2,6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorizedEl 1:1 ❑ <br /> dampers that automatically shut when not in use <br /> and meet maximum leakage rates.Check gravity <br /> dampers where allowed. <br /> HVAC 6.4.3.4.5 Mechanical Enclosed parking garage ventilation has <br /> automatic contaminant detection and capacity to <br /> stage or modulate fans to 50%or less of design <br /> capacity. <br /> HVAC 6.6.3.2.1 Mechanical DX cooling systems>=75 kBtu/h(>=65 kBtu/h ❑ 0 El <br /> effective 112016)and chilled-water and <br /> evaporative cooling fan motor hp>=A''Y4 designed <br /> to vary indoor fan airflow,as a function of load and <br /> comply with operational requirements. <br /> HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from <br /> damage.Insulation outside of the conditioned <br /> space and associated with cooling systems is <br /> vapor retardant. <br /> HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated. Where ducts ❑ <br /> or plenums are installed in or under a slab, <br /> verification may need to occur during Foundation <br /> Inspection. <br /> HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. Where piping <br /> is installed in or under a slab,verification may <br /> need to occur during Foundation Inspection. <br /> HVAC 6.4.4.2.1 Mechanical Ducts and plenums sealed based on static El 1:1 El <br /> pressure and location. <br /> SYSTEM—SPECIFIC 6.4.4.2.2 Mechanical Ductwork operating>3 in.water column requires <br /> air leakage testing. <br /> SYSTEM—SPECIFIC 6.5.2.1 Mechanical Zone controls can limit simultaneous heating and Q El ❑ <br /> cooling and sequence heating and cooling to each <br /> - zone. <br /> SYSTEM—SPECIFIC 6.5.2.2.2 Mechanical Two-pipe hydronic systems using a common <br /> distribution system have controls to allow a <br /> deadband>=15 A°F,allow operation in one mode <br /> for at least 4 hrs before changeover,and have <br /> rest controls to limit heating and cooling supply <br /> temperature to<=30 A°F. <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017—- <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation ASH RAE 90.1-2013-Prescriptive Compliance Option <br /> 7/6/2018" Page"12 of 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.