IKO <br /> Installation Instructions for <br /> Asphalt Shingles <br /> Page 4 of 5 <br /> IKO Hip and Ridge 12 Application Instructions <br /> (ASTM D3161, Class F—IKO Hip and Ridge 12) <br /> NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED <br /> APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION <br /> CONFLICT,THESE INSTRUCTIONS WILL GOVERN. <br /> Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide.These shingles are <br /> designed'for a 51/8"(130 mm)exposure.(For a neater appearance,the top of each side of each piece has <br /> been factory trimmed on a 1"(25 mm)taper(see drawing).Bend each piece over the hip or ridge,and nail 5 <br /> 5/8"(143 mm)above the butt edge 1"(25 mm)in from each edge, exposing each piece 5 118"(130 mm). <br /> Apply hip pieces starting at the lower end of the hip,working up toward the ridge.On hip roofs,apply ridge <br /> pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end <br /> opposite to the prevailing wind direction and continue to the other end.Note:To obtain a three-dimensional <br /> effect,(which is recommended,but not required),apply hip and ridge shingles double thickness by stacking 2 <br /> pieces on top of one another,the lower piece extending about 3/4"(19 mm)further than the top piece(see <br /> diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be <br /> covered with cement.Prior to application in cold weather,storing the shingles in a heated area will allow for <br /> easier bending. <br /> NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEYARE DESIGNED FOR USE AS HIP AND RIDGE <br /> SHINGLES ONLY,AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS.WE ASSUME NO <br /> RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POORAPPLICATION OR FAILURETO <br /> PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER <br /> VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.REVIEW <br /> ALL APPLICABLE BUILDING CODES,MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR <br /> TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. j <br /> M. • 1 t7s mrta ' <br /> Pe mo TAPER Gfr <br /> (taomm) O <br /> I <br /> ps2 mml < <br /> t <br /> F <br /> i <br /> t <br /> { <br /> f <br /> i <br /> i <br /> i <br /> PRI Construction Materials Technologies,I.I.C.6412 Badger Drive Tampa,FL 33610 Tel:813-621.5777 Fax 813-621.5540 e-mail:malerialstesting@p6cmi com WebSile:httpJMww prianLwm jI <br /> I <br /> i <br /> i <br /> f <br />