Laserfiche WebLink
a r <br /> GrounanG LUG inSTaLL <br /> Necessary Components: <br /> - One of the following ground lugs(or any UL 2703 compliant ground lug): <br /> Burndy CL50-1TN Ground-Lug(UL 2703-E351343./ UL467-E9999). <br /> ILSCO SGB-4 Ground Lug(UL 2703-E354420 /UL 467-E34440). <br /> 1LSC0 GBL-4DBT(UL 2703-E354420 /UL 467-E34440) <br /> ILSCO GBL-4DBTH(UL 2703-E354420 /.UL 467-E34440) <br /> ILSCO GBL-4SS(UL 2703-E354420 /UL 467-E34440) <br /> Note:Drill and.deburr hole in Ground'Lug prior to installation <br /> - 14 AWG-4AW.G Copper Ground Wire* Torque Values: <br /> - $-32.x 0:5"Serrated Flange Head Bolt(300 Series SS) 14=10:AWG=20 in-Ibs. <br /> - 8-32 Serrated Flange Nut(300-Series SS) B.AWG=25 in-lbs. <br /> - 11/32"and.1/4"wrenches.or ratchets/sockets 6-4 AWG=.35 in-Ibs. <br /> 1 Insert the flange bolt Into the module.ground.hole.Place Star Washer over bolt.Place ground lug over the bolt.and <br /> Star.Washer,and turn to desired orientation. <br /> 2 .Install Flange Nut. <br /> 3 Tighten Flange Nut/Bolt. <br /> 4 Place wire in Ground Lug channel and tighten setscrew to.complete assembly. <br /> *Wire should besized in accordance with the National Electrical Code,NFPA 70;Section 690.45,and a minimum of <br /> 1/4"clearance required between bare copper wire and aluminum. <br /> ' Drlil.hole per.grounding lug manufacturers <br /> specifications in the upslope part of Rock4t Coupling <br /> t for attaching grounding lug. <br /> Note:Deburr-hole in Ground Lug and Rock-It Coupling prior to'installation. <br /> www:ecofastensolarcom info@ecofastensolarcom 877-859-3947 6 <br />