My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22257
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22257
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:52:55 AM
Creation date
3/25/2021 10:52:54 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-22257
Building Department - Name
DR HORTON
Address
8056 WHEAT STONE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> � I <br /> Single Family D elling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F: .C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> C 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R..O:W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met. <br /> 9. No electric,.plumbing; mechanical, or framing shall e covered without an inspection and <br /> approval first.. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where ubject to meolanical damage unless <br /> protected by approved barriers. M303.4 of the F.B. <br /> 12. Water heaters shall comply with section P607.3 of the.F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.-C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance wi h R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance wit i R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R3 1 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F;B.C. <br /> 10. Combination-type AFCI breakers are required at all o_ cations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new co struction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit-. This includes all <br /> underground,plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.