<br />OUTLINE SPECIFICATION
<br />06 00 00 - WOOD, PLASTICS AND COMPOSITES - COMMON WORK RESULTS
<br />07 84 46 - FIRE -RESISTIVE JOINT SYSTEMS
<br />08 3100 - ACCESS DOORS AND PANELS
<br />I. PROVIDE WOOD PRODUCTS FOR WHICH ALL SOLID AND VENEER WOOD MATERIAL ORIGINATES FROM A SUSTAINABLY MANAGED FOREST CERTIFIED BYA
<br />1. PROVIDE RATED SYSTEMS PER ASTM E 814 or UL 1479 AT PENETRATIONS OF RATED CONSTRUCTION.
<br />1. PROVIDE ACCESS DOORS AND PANELS AS SHOWN ON THE DRAW NGS AND AS REQUIRED FOR ACCESS TO UTILITIES AND EQUIPMENT. FURNISH EACH
<br />FOREST STEWARDSHIP COUNCIL (FSC) ACCREDITED CERTIFICATION AGENCY.
<br />2. PERFORMANCE REQUIREMENTS:
<br />ACCESS DOOR ASSEMBLY MANUFACTURED AS AN INTEGRAL UNIT, COMPLETE WTH ALL PARTS, AND READY FOR INSTALLATION.
<br />2. ADHERE WOOD VENEER AND PLASTIC LAMINATE TO SUBSTRATE USING ADHESIVES THAT COMPLY WITH LO -VOC (VOLATILE ORGANIC COMPOUND)
<br />A. F-RATINGS: PROVIDE FIRESTOP SYSTEMS WTH F RATINGS EQUALING OR EXCEEDING FIRE -RESISTANCE RATING OF CONSTRUCTIONS PENETRATED
<br />A FIRE -RATED ACCESS DOORS AND FRAMES: UNITS COMPLYING WITH NFPA 80 THAT ARE IDENTICAL TO ACCESS DOOR AND FRAME ASSEMBLIES
<br />REQUIREMENTS.
<br />AS DETERMINED PER ASTM E 814.
<br />TESTED FOR FI RE -TEST -RESPONSE CHARACTERISTICS PER THE FCLLOVMNG TEST METHOD AND THAT ARE LISTED AND LABELED BY UL.
<br />B. T-RATINGS: PROVIDE FIRESTOP SYSTEMS WTH T-RATINGS REQUIRED, AS WELL AS F-RATINGS, DETERMINED PER ASTM E 814, WHERE SYSTEMS
<br />B. VERTICAL ACCESS DOORS AND FRAMES TESTED PER NFPA252 or UL 10B.
<br />PROTECT PENETRATING ITEMS WITH POTENTIAL TO CONTACT ADJACENT MATERIALS IN OCCUPIABLE FLOOR AREAS INCLUDING, BUT NOT LIMITED, TO
<br />C. HORIZONTAL ACCESS DOORS AND FRAMES TESTED PER ASTM Ell9 or UL 263.
<br />3. USE COMPOSITE WOOD PRODUCTS THAT CONTAIN NO UREA FORMALDEHYDE
<br />THE FOLLOWING:
<br />2. FLUSH METAL ACCESS DOORS AND TRI MLESS FRAMES:
<br />3. PENETRATIONS LOCATED OUTSIDE WALL CAVITIES.
<br />A MATERIAL:
<br />4. USE WOOD,PLASTIC ANDUS,RF COMPOSITE MATERIALS WHERE APPLICABLE IN ACCORDANCE WITH LEED REQUIREMENTS FOR SPECIFIED MATERIALS REGARDLESS
<br />4. PENETRATIONS LOCATED OUTSIDE FIRE -RESISTIVE SHAFT ENCLOSURES.
<br />I. PAINTED GYP. BD.. SURFACES: PRIME -PAINTED COLD -ROLLED STEEL SHEET, ASTM A 1008/A 1008M, CONHVIERCIAL STEEL (CS), EXPOSED.
<br />LEED ERTI
<br />CERTIFICATION STATUS, REFERENCE SECTION 01.81.13 SUSTAINABLE DESIGN REQUIREMENTS FOR APPLICABLE CREDITS AND SUSTAINABI LITY
<br />5, PENETRATIONS LOCATED IN CONSTRUCTION CONTAINING FIRE -PROTECTION -RATED OPENINGS.
<br />11. TILE SURFACES (TOILET ROOMS): STAINLESS STEEL, ASTM A 666, TYPE 304. REMOVE TOOL AND DIE MARKS AND STRETCH LINES OR BLEND
<br />INFORMATION.
<br />INFORMATION.
<br />TION.
<br />6. PENETRATING ITEMS LARGER THAN 4-INCH- (100-MM-) DIAMETER NOMINAL PIPE OR 16 SQ. IN. (100 SQ. CM) IN OVERALL CROSS -SECTIONAL AREA
<br />INTO DIRECTIONAL SATIN NO. 4 FINISH.
<br />A FOR FIRESTOP SYSTEMS EXPOSED TO VIEW, TRAFFIC, MOISTURE, AND PHYSICAL DAMAGE, PROVIDE PRODUCTS THAT AFTER CURING DO NOT
<br />B. DOOR MINIMUM 0.060-INCH (1.5-MM) THICK SHEET METAL, SET FLUSH WITH SURROUNDING FINISH SURFACES.
<br />5. PROVIDE THE FOLLOWING SUBMITTALS:
<br />DETERIORATE WHEN EXPOSED TO THESE CONDITIONS BOTH DURING AND AFTER CONSTRUCTION.
<br />C. FRAME: MINIMUM 0.060-INCH (1.5-MM) THICK SHEET METAL WITH BEAD FOR TYPE OF SURFACE INDICATED.
<br />A GRADE: CUSTOM.
<br />B. FOR THROUGH -PENETRATION FIRESTOP SYSTEMS EXPOSED TO VIEW, PROVIDE PRODUCTS WITH FLAME -SPREAD INDICES OF LESS THAN 25 AND
<br />D HARDWARE:
<br />B. FINISH: AW SYSTEM TR-4, CONVERSION VARNISH; W SYSTEM #2, CONVERSION VARNISH.
<br />SMOKE -DEVELOPED INDICES OF LESS THAN 450, WHEN TESTED PER ASTM E 84.
<br />I. HINGES: CONCEALED PIN TYPE.
<br />C. STAINING, EFFECT, SHEEN: MATCH APPROVED SAMPLES.
<br />C. FIRE -TEST -RESPONSE CHARACTERISTICS: PROVIDE RATED SYSTEMS IDENTICAL TO THOSE TESTED PER ASTM E 814 AND WITH PRODUCTS
<br />II. LATCH: SCREWDRIVER -OPERATED CAM LATCH.
<br />6. INSTALL WOODWORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS. INSTALL TOATOLERANCE
<br />BEARING THE CLASSIFICATION MARKING OFAQUALIFIED TESTING AND INSPECTINGAGENCY ACCEPTABLE TOAUTHORITIES HAVINGJURISDICTION.
<br />E. MANUFACTURERS: KAPPASSOCIATES, INC.,MILOOR,INC.,CRAPPRCNEDEQUAL.
<br />1/8-INCH IN FOR PLUMB AND LEVEL (INCLUDING TOPS); AND WITH NO VARIATIONS IN FLUSHNESS OF ADJOINING SURFACES. COMPLY WITH
<br />7. FIRESTOP SYSTEMS: COMPATIBLE WITH THE SUBSTRATES FORMING OPENINGS, AND WITH THE ITEMS, IF ANY, PENETRATING FIRESTOP SYSTEMS,
<br />3. GFRG PANELS FOR EXPOSED GYPSUM BOARD CEILINGS:
<br />IN REQUIREMENTS
<br />INSTALLATION FREQUI REMENTS ESTABLISHED BY REFERENCED STANDARDS.
<br />UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY MANUFACTURER BASED ON TESTING AND FIELD EXPERIENCE.
<br />A MATERIAL /CONSTRUCTION: HIGH DENSITY GYPSUM, COMPLETELY FREE OF BOTH ASBESTOS AND RESIN, REINFORCED WITH CONTINUOUS RANDOM
<br />8. ACCESSORIES: PROVIDE ACCESSORIES REQUIRED TO INSTALL FILL MATERIALS THAT COMPLY WITH REQUIREMENTS OF TESTED ASSEMBLIES, ARE
<br />FILAMENT GLASSFIBER NWT.
<br />7. FINISH HARDWARE ITEMS
<br />APPROVED BY QUALIFIED TESTING AND INSPECTING AGENCY THAT PERFORMED TESTING, AND ARE SPECIFIED BY MANUFACTURER OF TESTED
<br />I. SHELL THICKNESS: 1/8 - 3/16-INCH
<br />A DRAWER GLIDES: NO. 8400 BOX/FILE DRAWER SLIDE - FULL EXTENSION BY KNAPE & VOGT MFG. CO OR APPROVED EQUAL
<br />ASSEMBLIES.
<br />B. SHELF STANDARDS AND SUPPORTS (RECESSED SHELVES IN ENCLOSED CABINETS): N0255 STANDARD AND NO.256 SUPPORTS BY KNAPE & VOGT MFG.
<br />B. FABRICATION: UNITS TO BE SUITABLY REINFORCED WITH STEEL OR WOOD. FINISH COMPATIBLE WTH LEVEL 5 GYPSUM BOARD FINISH.
<br />9. INSTALL THROUGH -PENETRATION FIRESTOP SYSTEMS TO MEET RATINGS REQUIRED AND TO COMPLY WITH FIRESTOP SYSTEM MANUFACTURERS
<br />C. MANUFACTURERS: INTEX FORMS, PLASTERGLASS INC., ORAPPROVED EQUAL.
<br />CO., NATURAL ALUMINUM FINISH OR APPROVED EQUAL
<br />WRITTEN INSTALLATION INSTRUCTIONS AND PUBLISHED DRAWINGS FOR PRODUCTS AND APPLICATIONS INDICATED.
<br />c. DOORS: 1 PAIR HEAVY-DUTY INSTITUTIONAL HINGES, STANLEY HT1592, US 28, SATIN ALUMINUM FINISH
<br />I. 1 CATCH, STANLEY41 SERIES
<br />IL 1 PULL, HAFELE 124.02.921 MATTE ALUMINUM FINISH
<br />08 7100 - DOOR HARDWARE
<br />07 92 00 -JOINT SEALANTS -INTERIOR WORK
<br />D. DRAWER PULLS: HAFELE 124.02.921 MATTE ALUMINUM FINISH
<br />1, PROVIDE COMMERCIAL DOOR HARDWARE FOR OPENINGS SHOWN.
<br />E. DRAWER LOCKS: SCHLAGE CL 2000 CABINET DRAWER LOCK, US26D COMPLETE WITH STRIKE PLATE
<br />1. VOC CONTENT OF INTERIOR SEALANTS: PROVIDE INTERIOR SEALANTS AND SEALANT PRIMERS THAT COMPLY WTH THE FOLLOWING LIMITS FOR VOC
<br />8. DOOR LOCKS: SCHLAGE CL1000 CABINET DOOR LOCK, US261D, COMPLETE WITH STRIKE PLATE. PROVIDE ONE ELBOW CATCH PER PAIR DOORS. MASTER KEY
<br />CONTENT W-IEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24); 250 G/L FOR SEALANTS AND SEALANT PRIMERS FOR NONPOROUS
<br />2. COORDINATION: COORDINATE DOOR HARDWARE WITH OTHER WORK. FURNISH SHOP DRAWINGS OF OTHER WORK WHERE REQUIRED OR REQUESTED TO
<br />ALL LOCKS AND PROVIDE KEY SCHEDULE TO TENANT
<br />SUBSTRATES; 775 G/L. FOR SEALANT PRIMERS FOR POROUS SUBSTRATES.
<br />COORDINATE INSTALLATION.
<br />A SILENCERS: NEOPRENE TYPE WITH SELF-ADHESIVE AT ALL CABINET DOORS
<br />2. GENERAL SEALANT (ACRYLIC -EMULSION): MANUFACTURERS STANDARD, ONE -PART, NON -SAG, MILDEW -RESISTANT, ACRYLIC -EMULSION SEALANT
<br />COMPLYING WITH ASTM C 834, FORMULATED TO BE PAINTABLE AND RECOMMENDED FOR EXPOSED APPLICATIONS ON INTERIOR AND PROTECTED EXTERIOR
<br />3. PREPARE DOOR HARDWARE SCHEDULE UNDER THE SUPERVISION OF SUPPLIER, DETAILING FABRICATION AND ASSEMBLY OF DOOR HARDWARE, AS WELL AS
<br />PROCEDURES AND DIAGRAMS. COORDINATE THE FINAL DOOR HARDWARE SCHEDULE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE,
<br />0610 00 - ROUGH CARPENTRY
<br />EXPOSURES INVOLVING JOINT MOVEMENT OF NOT MORE THAN 7.5%.
<br />THICKNESS, HAND, FUNCTION, AND FINISH OF DOOR HARDWARE.
<br />1. PROVIDE WOOD FOR SUPPORT OR ATTACHMENT OF OTHER WORK I NCLUDI NG ROOFTOP EQUIPMENT CURBS AND SUPPORT BASES, CANT STRIPS, BUCKS,
<br />A FORMAT: COMPLY WITH SCHEDULING SEQUENCE AND VERTICAL FORMAT IN DOOR HARDWARE INSTITUTES "SEQUENCE AND FORMAT FOR THE
<br />NAILERS, BLOCKING, FURRING, GROUNDS.
<br />3. SANITARY SEALANT: ONE -PART MILDEW -RESISTANT SILICONE SEALANT: TYPE S; GRADE NS; CLASS 25; USES NT, G, A, AND, AS APPLICABLE TO
<br />HARDWARE SCHEDULE."
<br />NONPOROUS JOINT SUBSTRATES INDICATED, O; FORMULATED WITH FUNGICIDE; INTENDED FOR SEALING INTERIOR JOINTS WTH NONPOROUS SUBSTRATES
<br />B. ORGANIZATION: ORGANIZE THE DOOR HARDWARE SCHEDULE INTO DOOR HARDWARE SETS INDICATING COMPLETE DESIGNATIONS OF EVERY ITEM
<br />2. STRIPPING AND SIMILAR MEMBERS. PROVIDE LUMBER OF SIZES INDICATED, WORKED INTO SHAPES SHOWN.
<br />AND SUBJECT TO IN-SERVICE EXPOSURE TO CONDITIONS OF HIGH HUMIDITY AND TEMPERATURE EXTREMES. PRODUCT - DOVV CORNING 786 OR GE SILICONES;
<br />REQUIRED FOR EACH DOOR OR OPENING.
<br />SANITARY 1700.
<br />C. PROVIDE COMPLETE HARDWARE SETS FOR ALL OPENINGS SHONN, IN COMPLIANCE WITH LOCAL CODES AND INDUSTRY STANDARDS.
<br />3. MOISTURE CONTENT: 19 PERCENT MAXIMUM FOR LUMBER ITEMS, INCLUDING ITEMS TO RECEIVE WOOD PRESERVATIVE TREATMENT OR FIRE
<br />D. WHERE REQUIRED TO MATCH EXISTING BUILDING ITEMS, PROVIDE MANUFACTURERS AND PRODUCTS THAT MATCH BUILDING STANDARD.
<br />RETARDANT TREATMENT.
<br />E. COORDINATE DOOR FUNCTION AND KEYING WITH TENANT / OWNER
<br />4. FIRE -RATED DOOR ASSEMBLIES: PROVIDE DOOR HARDWARE FOR ASSEMBLIES COMPLYING WTH NFPA 80 THAT ARE LISTED AND LABELED BYA TESTING AND
<br />4. GRADE: STANDARD GRADE LIGHT FRAMING SIZE LUMBER OF ANY SPECIES OR BOARD SIZE LUMBER AS REQUIRED. N0.3 COMMON OR STANDARD GRADE
<br />08 1113 -HOLLOW METAL DOORS AND FRAMES - (STEEL)
<br />INSPECTING AGENCYACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, FOR FIRE RATINGS INDICATED, BASED ON TESTING ACCORDING TO NFPA 252.
<br />BOARDS PER SPI B, WIVCLIB OR W APA RULES APPLICABLE TO AGENCY UNDER WHICH LUMBER IS GRADED.
<br />1. STEEL DOOR AND FRAME STANDARD: COMPLY WITH ANSI A 250.8, UNLESS MORE STRINGENT REQUIREMENTS ARE INDICATED.
<br />5. SUPPLIER QUALIFICATIONS: DOOR HARDWARE SUPPLIER WITH WAREHOUSING FACILITIES IN PROJECTS VICINITY AND WHO IS OR EMPLOYS A QUALIFIED
<br />5. PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS WITH
<br />2. FIRE -RATED DOOR ASSEMBLIES: ASSEMBLIES OOMPLYING WITH NFPA 80 THAT ARE LISTED AND LABELED, FOR FIRE -PROTECTION RATINGS INDICATED,
<br />ARCHITECTURAL HARDWARE CONSULTANT, AVAILABLE DURING THE COURSE OF THE WORK TO CONSULT WITH CONTRACTOR, ARCHITECT, AND OWNERABOUT
<br />GRADE DESIGNATION, APA C-D PLUGGED INT WITH EXTERIOR GLUE, IN THICKNESS INDICATED, OR. IF NOT OTHERWISE INDICATED, NOT LESS THAN 314-INCH
<br />BASED ON TESTING ACCORDING TO NFPA252.
<br />DO ARE AND KEYING
<br />6. FIRE -RETARDANT TREATMENT: WHERE FIRE -RETARDANT TREATED WOOD IS REQUIRED BY CONSTRUCTION TYPE, PRESSURE IMPREGNATE LUMBER AND
<br />3. COLD -ROLLED STEEL SHEETS: ASTM A 366/A 366M, COMMERCIAL STEEL (CS), OR ASTM A 620/A 620M, DRAWING STEEL (DS), TYPE B; STRETCHER
<br />6. INSTALL EACH DOOR HARDWARE ITEM TO COMPLY WITH MANUFACTURERS WRITTEN INSTRUCTIONS. PROVIDE DOOR REINFORCING AND BLOCKING FOR
<br />PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY.
<br />LEVELED STANDARD OF FLATNESS.
<br />INSTALLATION OF DOOR HARDWARE WITHOUT THRU-BOLTS. DO NOT INSTALL SURFACE -MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON
<br />SUBSTRATES INVOLVED. SET UNITS LEVEL, PLUMB, AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE ATTACHMENT SUBSTRATES AS NECESSARY
<br />7. PRESERVATIVE TREATMENT: PRESSURE PRESERVATIVE TREAT ALL ROOF CURBS, MAILERS AND BLOCKING WITH EXTERIOR EXPOSURE AND EXTERIOR
<br />4. METALLICOOATED STEEL SHEETS: ASTM A 65SA 653M, COMMERCIAL STEEL (CS), TYPE B, WITH AN A40 (ZF120) ZINC -IRON] -ALLOY (GALVANNEALED)
<br />FOR PROPER INSTALLATION AND OPERATION.
<br />ITEMS IN CONTACT WITH CONCRETE OR MASONRY WITH AM IVIONIACAL, OR AMINE, COPPER QUAT (ACQ) IN ACCORDANCE WITH A/VPA C2 (LUMBER) AND AWPA
<br />COATING; STRETCHER -LEVELED STANDARD OF FLATNESS.
<br />C9 (PLYWOOD).
<br />5. DOORS AND FRAMES SHALL OOMPLYI NG WITH ANSI 250.8.
<br />06 40 00 -ARCHITECTURAL WOODWORK
<br />08 80 00 -GLAZING
<br />1. PROVIDE HUMANA PROJECT MANAGER WITH (3) COPIES OF ALL ARCHITECTURAL WOODWORK SHOP DRAWINGS PRIOR TO FABRICATION. HUMANA
<br />6. TYPICAL INTERIOR FRAMES SHALL BE WELDED CONSTRUCTION.
<br />1. MATERIALS: AS SCHEDULED ON THE DRAWINGS.
<br />PROJECT MANAGER TO FORWARD (1) COPY TO ARCHITECT FOR REVIEW
<br />2. QUALITY STANDARDS: COMPLY WITH ONE OF THE FOLLOWING:
<br />7. DOOR INSTALLATION: COMPLY WITH ANSI A250.8. SHIM AS NECESSARY TO COMPLY WITH SDI 122 AND ANSI/DHI A115.1 G. INSTALL FIRE -RATED DOORS
<br />2. GLAZING FOR FIRE -RATED ASSEMBI I ES: GLAZING FOR ASSEMBLI ES THAT OOMAPLY WITH NFPA 80 AND THAT ARE LISTED AND LABELED BYA TESTING AND
<br />A AW'S"ARCHITECTURAL VvOODWORKQUALITYSTANDARDS"FOR GRADES OF INTERIOR ARCHITECTURAL WOODWORK CONSTRUCTION, FINISHES,
<br />WITHINCLEARANCES SPECIFIED INNFPA80. INSTALL SMOKE CONTROL DOORS TO COMPLY WITH NFPA105.
<br />INSPECTING AGENCYACCEPTABLE TOALITHORITIES HAVING JURISDICTION, FOR FIRE RATINGS INDICATED, BASED ON TESTING ACCORDING TO NFPA257.
<br />AND OTHER REQUIREMENTS. PROVIDE AAA CERTIFICATION LABELS OR COMPLIANCE CERTIFICATE INDICATING THAT WOODWORK COMPLIES WITH
<br />REQUIREMENTS OF GRADES SPECIFIED.
<br />8. PLACING FRAMES: COMPLY WITH PROVISIONS IN SDI 105, UNLESS OTHERWISE INDICATED. SET FRAMES ACCURATELY IN POSITION, PLUMBED,
<br />3. SAFETY GLAZING PRODUCTS: COMPLY WITH TESTING REQUIREMENTS IN 16 CFR 1201 AND, FOR WIRED GLASS, ANSI Z97.1.
<br />B. VU (FORMERLY WC) "MANUAL OF MILLWORK' FOR GRADES OF INTERIOR ARCHITECTURAL WOODWORK, CONSTRUCTION, FINISHES, AND OTHER
<br />ALIGNED, AND BRACED SECURELY UNTIL PERMANENT ANCHORS ARE SET.
<br />REQUIREMENTS. PROVIDE WC -CERTIFIED COMPLIANCE CERTIFICATE INDICATING THAT WOODWORK COMPLIES WITH REQUIREMENTS OF GRADES
<br />4. GLAZING PUBLICATIONS: COMPLY WITH PUBLISHED RECOMMENDATIONS OF GLASS PRODUCT MANUFACTURERS AND ORGANIZATIONS BELOW, UNLESS
<br />SPECIFIED. PROVIDE WC -CERTIFIED COMPLIANCE CERTIFICATE FOR INSTALLATION.
<br />MORE STRINGENT REQUIREMENTS ARE INDICATED. REFER TO THESE PUBLICATIONS FOR GLAZING TERMS NOT OTHERWISE DEFINED IN THIS SECTION OR
<br />3. PROVIDE MATERIALS THAT COMPLY WITH REQUIREMENTS OF THE REFERENCED PRODUCT STANDARDS FOR GRADE INDICATED.
<br />IN REFERENCED STANDARDS.
<br />081216 - INTERIOR ALUMINUM FRAMES
<br />a. GLASS ASSOCIATION OF NORTH AMERICA (GANA) PUBLICATIONS: GANA LAMINATED DIVISION'S "LAMINATED GLASS DESIGN GUIDE" AND GANNS
<br />4. HARDBOARD: ANSVAHAA135.4.
<br />1. ALUMINUM MEMBERS: ALLOY AND TEMPER RECOMMENDED BY THE MANUFACTURER FOR STRENGTH, CORROSION RESISTANCE, AND APPLICATION OF
<br />"GLAZING MANUAL."
<br />REQUIRED FINISH; COMPLY WITH ASTM B 221 FOR ALUMINUM EXTRUSIONS, ASTM B 209 FOR ALUMI NUM SHEET OR PLATE, AND ASTM B 211 FORALUMINUM
<br />5. MEDIUM DENSITY FIBERBOARD (MDF): ANSI A208.2; FORMALDEHYDE FREE.
<br />BARS, RODS AND WIRE.
<br />09 00 00 - FINISHES - COMMON WORK RESULTS
<br />1. ADHESIVES: USE WATER-RESISTANT, LOW ODOR, LOVV VOLATILE, NON -TOXIC AND EMIT LESS THAN EPA MAXIMUM EMISSION RATE GUIDELINE OF
<br />6. PARTICLEBOARD: NOT ALLOW/bED.
<br />2. CARBON STEEL REINFORCEMENT OF ALUMINUM FRAMING MEMBERS SHALL COMPLY WTH ASTM A 36 FOR STRUCTURAL SHAPES, PLATES AND BARS,
<br />0.6 MG/M2 HP, FOR VOLATILES; VOC CONTENT OF 65 C�/L OR LESS WHEN CALCULATED ACCORDING TO 40 CFR 59, SUBPART D (EPA METHOD 24); AND
<br />ASTM A 611 FOR COLD ROLLED SHEET AND STRIP, OR ASTM A 570 FOR HOT ROLLED SHEET AND STRIP.
<br />MEETING GOVERNMENT REQUIREMENTS, AND AS RECOMMENDED BY MANUFACTURER TO SUIT PRODUCTS AND SUBSTRATE CONDITIONS INDICATED.
<br />7. SOFTVbC"lOD PLYWCOD: PSI.
<br />3. FRAMING SYSTEM: PROVIDE ALUMINUM FRAMING SYSTEMS FABRICATED FROM EXTRUDED ALUMINUM MEMBERS OF SIZE AND PROFILE INDICATED.
<br />2. BASIS OF DESIGN FINISH PRODUCTS ARE SCHEDULED ON THE DRAWINGS.
<br />8. FORMALDEHYDE EMISSION LEVELS: PROVIDE FORMALDEHYDE FREE MATERIALS.
<br />INCLUDE SUBFTAMES AND OTHER REINFORCING MEMBERS REQUIRED FOR PERFORMANCE. - RACO SOLUTIONS II OR EQUAL.
<br />a. SNARIN TYPE GLAZING BEADS WTH MANUFACTURERS STANDARD NEOPRENE GASKETS.
<br />3. INSTALLER QUALIFICATIONS: MINIMUM 3 YEARS EXPERIENCE IN WORK OF APPLICABLE SECTIONS.
<br />9. FABRICATION: COMPLY WTH DETAILS AND CONSTRUCTION TYPES INDICATED.
<br />b. CORNERS SHARP WITH ALL JOINTS MITERED HAIRLINE, UNLESS OTHERWSE SHOWN. MITRE ALL
<br />c. CORNERS WHERE OPEN ENDS OF EXTRUSIONS OR VOIDS WOULD BE VISIBLE IF BUTTJ01NTS WERE
<br />4. SAMPLES: PROVIDE SAMPLES OF SIZE SUITABLE FOR REVIEW.
<br />10. CABINET HARDWARE AND ACCESSORY MATERIALS: AS INDICATED ON DRAWINGS AND SCHEDULES.
<br />d. USED. THIS INCLUDES SIDELIGHTS AND OVERHEAD BORROWVED LIGHT FRAMES.
<br />A SAMPLES FOR INITIAL SELECTION: SUBMIT FOR COMPONENTS WTH FACTORY -APPLIED COLOR FINISHES NOT PRE -SELECTED.
<br />B. SAMPLES FOR VERIFICATION (PRE -SELECTED COLORS AND PRODUCT CHARACTERISTICS): SUBMIT FOR EACH COMPONENT INDICATED AND FOR
<br />11. FACTORY FINISHING OF INTERIOR ARCHITECTURAL WOODWORK
<br />4. PROVIDE SUITABLE ANCHORAGE FOR FAGH WALL CONDITION, TO INCLUDE SILL ANCHORAGE AT DOORS, HEAD ANCHORAGE AT ALL OPENINGS 3-FEEL'-0-
<br />EACH EXPOSED FINISH REQUIRED
<br />A AW SECTION 1500, UNLESS OTHERWSE INDICATED.
<br />I NCH AND W DER, INTERMEDIATE EVENLY SPACE JAMB ANCHORS NOT TO EXCEED 2-FEET-0-INCH IN CENTER ALL FRAME FASTENINGS AND ANCHORS
<br />B. W SECTION 1, "GENERAL INFORMATION -TECHNICAL BULLETIN", REQUIREMENTS FOR "FACTORY FINISHING OF MILLWORK'
<br />SHALL BE CONCEALED.
<br />5. WARRANTIES: WARRANT FINISH PRODUCTS AGAINST
<br />C. GRADE: CUSTOM.
<br />A CARPET INSTALLATION: 2 YEAR WARRANTY- DEFECTIVE MATERIALS AND WORKMANSHIP, ISSUED JOINTLY BY FINISH MATERIAL MANUFACTURER,
<br />D. FINISH: AW SYSTEM TR4, CONVERSION VARNISH; W SYSTEM 42, CONVERSION VARNISH.
<br />5. REINFORCEMENT: PROVIDE REINFORCEMENT AT BUILDERS HARDWARE AND TO PREVENT DISTORTION OF FRAMES.
<br />CONTRACTOR, AND INSTALLER
<br />E. STAINING, EFFECT, SHEEN: TO MATCH APPROVED SAMPLES.
<br />B. CARPET MATERIAL: MANUFACTURERS LIMITED 10-YEAR COMMERCIAL WEAROUT/ DELAMINATING/TUFT-BIND WARRANTY.
<br />6. MACHINE ALUMINUM FRAMES FOR MOUNTING OF HARDWARE.
<br />6. EXTRA STOCK PROVIDE 2 PERCENT OF EACH CARPET TO THE OWNER.
<br />12. INSTALL WOODWORK PLUMB, LEVEL, TRUE AND STRAIGHT WTH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS, INSTALL TOA
<br />TOLERANCE OF 1/8-INCH IN 8-FEET-0-INCHES FOR PLUMB AND LEVEL (INCLUDING TOPS); AND WTH NO VARIATIONS IN FLUSHNESS OF ADJOINING
<br />7. PROVIDE REINFORCEMENTS AT HINGE LOCATIONS, STRIKES, AND AT CLOSERS.
<br />7. INSTALL FINISH MATERIALS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS TO MEET PROJECT REQUIREMENTS INDICATED.
<br />SURFACES. OOMPLY WTH INSTALLATION REQUIREMENTS ESTABLISHED BY REFERENCED STANDARDS.
<br />8. COMPLY WTH MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS FOR INSTALLATION.
<br />8. MOISTURE VAPOR EMISSION TESTS - FLOORING: TEST EACH 1,000-SQ. Fr. (92.9-SQ M) OF FLOORING SUBSTRATE, OR PORTION THEREOF, WITH AN
<br />13. FINISH HARDWARE ITEMS
<br />ANHYDROUS CALCIUM CHLORIDE TEST KIT EQUIVALENT TO THE VAPRECISION TEST KIT PRODUCED BY VAPRECISION PROFESSIONAL VAPOR EMISSION
<br />a. All hardware (pulls, hinges, etc) to have Satin Bronze finish, US 10 where ever possible - if not available, submit substitution to designer for approval
<br />9. SET UNITS PLUMB, LEVEL, AND TRUE TO LINE, WITHOUT WARP OR RACE OF FRAMING MEMBERS, DOORS, OR PANELS. INSTALL COMPONENTS IN PROPER
<br />TESTING SYSTEMS, NEVVPCIFRT BEACH, CA (TEL) 800-449-6194.
<br />b. Drawer Glides: No. 8400 Box/File Drawer Slide -Full E)dension by Knape & Vogt Mfg. Co, or approved equal
<br />ALIGNMENT AND RELATION TO ESTABLISHED LINES AND GRADES INDICATED. PROVIDE PROPER SUPPORT AND ANCHOR SECURELY IN PLACE.
<br />A CONDUCT TESTS FORA MINIMUM OF 72 HOURS I N ACCORDANCE WTH THE TEST KIT MANUFACTURERS PRINTED INSTRUCTION S.
<br />c. Shelf Standards and Supports (recessed shelves in enclosed cabinets): No 255 Standard and No. 256 Supports by Knape & Vogt Mfg. Co.
<br />B. AN EMISSION RATE OF LESS THAN 3.0-LB/1,000 SQ FT (14.6-KG/SQ M) IN 24-HOURS INDICATES THAT SUBSTRATE IS ACCEPTABLE FOR FLOORING
<br />d. Doors: 1 pair concealed hinges: concealed, self -closing of hinges of required door construction and stile applications. The size and nun -be rof hi rs
<br />pa' rage rg typetype roq by l>�� � required
<br />10. PROVIDE ALUMINUM ANODIZED BRONZE FINISH UNLESS OTHEWSE NOTED.
<br />INSTALLATION.
<br />per leaf shall be et41 Send by door size and weight. hinges shall comply with the ANSI/BHMA grade 1 requirements. Manufacturers: Hafele, Grass, Blum, or Stanley
<br />C. IF EMISSION RATES ARE 3.0-LB/1,000 SQ FT (14.6-KG/SQ M) IN 24- HOURS OR GREATER ANYWIERE IN THE AREA TESTED, SUBMIT A WRITTEN TEST
<br />l
<br />1 catch, Stanley 41 Series
<br />REPORT TO ARCHITECT AND GIVER WTHIN 24-HOURS, INDICATING THE TYPE OF TEST KIT USED AND THE TEST RESULTS AT EACH LOCATION TESTED.
<br />f.
<br />f. 1 pull, Stanley 4484,
<br />08 14 10 - FLUSH WOOD DOORS
<br />D. IN ADDITION, SUBMIT A PROPOSAL TO FURNISH AND INSTALL A VAPOR,EMISSION CONTROL PENETRATE SYSTEM, OR A VAPOR EMISSION CONTROL
<br />g. Drawer Pulls: Stanley approved equal
<br />CI_ 2000 cabinet drawer lode, complete with strike plate
<br />h. Drawer e CL 0
<br />1. QUALITY STANDARD: COMPLY WTH NVNVDA I.S.1-A, "ARCHITECTURAL WOOD FLUSH DOORS."
<br />COATING SYSTEM, OR A VAPOR EMISSION CONTROL DISPERSAL MEMBRANE SYSTEM AS DICTATED BY TEST RESULTS AND PRODUCED BY FLOOR SEAL
<br />LocLocks ( e-reSchindicated
<br />i. Door Locks (where indicated in elevations}: Schlage CL1000 cabinet door lock complete with strike plate. Provide one elbow catch per pair doors. Mlaster key all lodes and
<br />2. FIRE -RATED WOOD DOORS: DOORS THAT ARE LISTED AND LABELED BYA TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING
<br />TECHNOLOGY, INC., SAN JOSE, CA (TEL) 800-572 2344, OR ONE OF THE APPROPRIATE "VAPRSTOP" FAST -CURE EPDXY OOI CRETE WATER SEALER SYSTEM
<br />JURISDICTION, FOR FIRE RATINGS INDICATED.
<br />PRODUCED BY DUPONT FLOORING SYSTEMS, KENNESAW, GA (TEL) W)-438-7668, VW� vV DUPONTCOMMERGMI
<br />AL.CO
<br />provide key e to tenant
<br />j. SI I enCerS: Neoprene type at all cabinet doors
<br />p
<br />a. TEST PRESSURE: BASED ON TESTING AT POSITIVE PRESSURE ACCORDING TO APPLICABLE CODE.
<br />14. Master key all lodes and provide key schedule to tenant
<br />3. DOORS FOR TRANSPARENT FINISH: PREMIUM GRADE ,WTH GRADE AA FAGS, SPECIES INDICATED.
<br />a. Silencers: Neoprene type with self-adhesive at all cabinet doors
<br />4. DOORS FOR OPAQUE FINISH: CUSTOM GRADE, WITH FACES OF CLOSED -GRAIN HARDWOOD.
<br />09 2216 - NON-STRUCTURAL METAL FRAMING
<br />07 8105 - PATCHING DAMAGED FIREPROOFING
<br />5. PLASTIC -LAMINATE -FACED DOORS: CUSTOM GRADE, HIGH-PRESSURE DECORATIVE LAMINATES COMPLYING WTH NEMA LD 3, GRADE HGS.
<br />1. QUALITY ASSURANCE:
<br />1. PROVIDE MATERIALS AND CONSTRUCTION THAT ARE IDENTICAL TO THOSE TESTED BY UNDERWRITFJR'S
<br />A FIRE -TEST -RESPONSE CHARACTERISTICS: FOR FIRE -RESISTANCE RATED ASSEMBLIES THAT INCORPORATE NON -LOAD -BEARING STEEL FRAMING,
<br />6. INTERIOR DOOR CONSTRUCTION: SOLID WOOD CORE, FIVE PLIES WTH STILES AND RAILS BONDED TO GORE, THEN ENTIRE UNIT ABRASIVE PLANED
<br />PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TOTHOSE TESTED IN ASSEMBLY INDICATED ACCORDING TO ASTM E 119 BYAN INDEPENDENT
<br />2. LABORATORY, INC., FOR FIRE RATED ASSEMBLY DESIGN NUMBERS INDICATED.
<br />BEFORE VENEERING. PROVIDE EITHER GLUED -BLOCK OR STRUCTURAL COMPOSITE LUMBER CORES INSTEAD OF PARTICLEBOARD CORES AT LOCATIONS
<br />TESTING AGENCY.
<br />WHERE EXIT DEVICES ARE I NDICATED.
<br />B. STCRATEDASSEMBLIES: FORST&RATEDASSEMBLIES, PROVIDE KATERIALS AND CONSTRUCTION IDENTICAL TOTHOSE TESTED IN ASSEIVIBLY
<br />3. DO NOT REMO/EANY SPRAYED -ON FIRE RESISTIVE MATERIAL WTHOUTPRIOR APPROVAL. RE -COAT
<br />INDICATEDACOORDING TOASTM E 90 AND CLASSIFIED ACCORDING TOASTM E 413 BY AN INDEPENDENT TESTING AGENCY.
<br />7. FIRE -RATED DOORS: CONSTRUCTION AND CORE SPECIFIED ABOVE FOR TYPE OF FACE INDICATED OR MANUFACTURERS STANDARD MINERAL -CORE
<br />4. FIRE RESISTIVE MATERIALS DAMAGED BY OTHER TRADES AND SURFACES WHERE FIRE RESISTIVE
<br />CONSTRUCTION AS NEEDED TO PROVIDE FIRE RATING INDICATED.
<br />2. STEEL FRAMING: COMPLY WTH ASTM C 754 FOR CONDITIONS INDICATED. K/ErAL COMPLYING WTH ASTM C 645 REQUIREMENTS, ASTM A 653/A 653M,
<br />a. EDGE CONSTRUCTION: INTUIVESC ENT SEALS CONCEALED BY OUTER STILE MATCHING FACE VENEER, AND LAMINATED BACKING FOR IMPROVED SCREW-
<br />C60 (Z180), HOT -DIP GALVANIZED ZINC COATING.
<br />5. MATERIAL HAS BEEN REMOVED FOR INSTALLATION OF RELATED WORK; COST OF REPAIRS TO BE
<br />HOLDING CAPABILITY AND SPLIT RESISTANCE.
<br />A FIRESTOP TRACKS: TOP RUNNER MANUFACTURED TO ALLOW PARTITION HEADS TO EXPAND AND CONTRACT WTH MOVEMENT OF THE
<br />b. PAIRS: FURNISH FORMED -STEEL EDGES AND ASTRAGALS WTH INTUMESCENT SEALS FOR PAIRS OF FIRE -RATED DOORS, UNLESS OTHERWISE
<br />STRUCTURE WHILE MAINTAINING CONTINUITY OF FIRE -RESISTANCE -RATED ASSEMBLY INDICATED; IN THICKNESS NOT LESS THAN INDICATED FOR STUDS
<br />6. BORNE BY RESPECTIVE TRADES.
<br />INDICATED.
<br />AND IN W DTH TOACCOMVIODATE DEPTH OF STUDS
<br />c. THE DOOR AND FRAME SHALL BEAR AN APPROVED LABEL OR OTHER IDENTIFICATION SHOVING THE RATING THEREOF, FOLLOWED BY THE LETTER "S",
<br />7. SPRAYED FIRE RESISTIVE MATERIAL: CEMENTATIOUS SPRAYED FIRE RESISTIVE MATERIAL CONSISTING OF FACTORY MIXED, DRY FORMULATION OF
<br />THE NAME OF THE MANUFACTURER AND THE IDENTIFICATION OF THE SERVICE CONDUCTING THE INSPECTION OF MATERIALS AND WORKMANSHIP AT THE
<br />3. GRID SUSPENSION SYSTEM FOR INTERIOR CEILINGS: ASTM C 645, DIRECT -HUNG SYSTEM COMPOSED OF MAIN BEAMS AND CROSS -FURRING MEMBERS
<br />GYPSUM OR PORTLAND CEMENT BINDERS AND LIGHTWEIGHT MINERAL OR SYNTHETIC AGGREGATES MIXED WITH WATER AT PROJECT SITE TO FORM A
<br />FACTORY DURING FABRICATION AND ASSEMBLY.
<br />THAT INTERLOCK.
<br />SLURRY OR MORTAR FOR CONVEYANCE AND APPLICATION AND AS REQUIRED FOR THE UL DESIGNS INDICATED.
<br />A CONCEALED APPLICATION: MATERIALS APPLIED TO SURFACES THAT ARE CONCEALED FROM VIEW BEHIND OTHER CONSTRUCTION WHEN THE
<br />8. BLOCKING: FOR MINERAL -CORE DOORS USE COMPOSITE BLOCKING WITH IMPROVED SCREVV-HOLDING CAPABILITY TO PROVIDE A MINIMUM 500 LB.
<br />4. FURRING CHANNELS (FURRING MEMBERS):
<br />WORK IS COMPLETED, INTENDED TO BE CONCEALED BYTENANT IMPROVEMENTS, AND WHICH HAVE NOT BEEN DEFINED AS EXPOSED.
<br />SCREW WTHDRAWAL RESISTANCE PER ASTM D 143/WWVDA TM-1 0 (NOW PUBLISHED BYWDhIIA) AND MINIMUM 200,000 SLAM CYCLES PER ANSI A
<br />A COLD -ROLLED CHANNELS: 0.0538-INCH (1.37-MM) BARE -STEEL THICKNESS, WTH MINIMUM 1/2-INCH- (12.7-MM-) WIDE FLANGES, 3/4 INCH (19.1 MM)
<br />151.1/WW\DATM-7 (NOW PUBLISHED BY W'DMA) WTHOU T FAILURE.
<br />DEEP.
<br />8. BASIS OF DESIGN PRODUCTS: W. R. GRACE - "MONOKOTE TYPE MK 6' FULLY CONCEALED; "RETRO-GUARD' REPAIRS.
<br />9. FINISH DOORS AT FACTORYTHAT ARE INDICATED TO RECEIVE TRANSPARENT FINISH. FIELD FINISH DOORS INDICATED TO RECEIVE OPAQUE FINISH.
<br />9. EXPOSED I NTERIOR APPUC ATION: MATERIALS ARE THOSE APPLIED TO SURFACES THAT ARE EXPOSED TO VIEW WHEN THE VORK IS COMPLETED,
<br />PROVIDE PREMIUM GRADE FINISH EQUAL TO MINDA I.S.1-A SYSTEM TR-4 CONVERSION VARNISH. MATCH ARCHITECTS APPROVED SAMPLE
<br />THAT ARE IN ELEVATOR SHAFTS AND MACHINE ROOMS, THAT ARE IN MECHANICAL ROOMS, AND THAT ARE IDENTIFIED AS EXPOSED ON DRAWINGS.
<br />10. INSTALL DOOMS TO COIVIPLY WTH MANUFACTURERS WRITTEN INSTRUCTIONS, REFERENCED QUALITY STANDARD, AND AS INDICATED. INSTALL FIRE-
<br />10. BASIS OF DESIGN PRODUCTS: "MIONOKOTETYPE Z106 & Z106/HY' EXPOSED I NTERIOR; "MIONOKOTEfYPE Z146' SUBJECT TO IMPACT.
<br />RATED DOORS IN CORRESPONDING FI RE -RATED FRAMES ACCORDING TO NFPA 80.
<br />�x.
<br />Project
<br />HUMANA- ZEPHYRHILLS,
<br />FLORIDA - GUIDANCE
<br />CENTER
<br />7920 GALL BLVD.
<br />ZEPHYRHILLS, FLORIDA 33541
<br />Prepared for
<br />HUMANA INC.
<br />Contract No: 12.01622.00
<br />HO K
<br />One Tampa City Center, Suite 1800
<br />Tampa, FL 33602 USA
<br />t +1 813 229 0300 f +1 813 223 7116
<br />FL Reg: AAC001139
<br />All reproduction & intellectual property rights reserved © 2012
<br />,In Association with
<br />SDM Consulting Engineers
<br />MEP Engineer
<br />135 Alrreria Ave_
<br />Coral Gables, FL 33134
<br />305.446.2788
<br />Key Plan
<br />Professional Seals
<br />N&V
<br />A
<br />Jonathan Rae License # AR009-4342
<br />No. Issue Description YYYY-MM-DD
<br />Drawn by Author Reviewed by Checker
<br />Project No 12.01622.00
<br />Sheet Title:
<br />OUTLINE SPEC.