0 <br />C11,1 <br />G <br />N$ <br />15<1 <br />SUPPLY AIR DUCT, <br />SECTION <br />RETURN/EXHAUST <br />AIR DUCT, SECTION <br />SUPPLY AIR DUCT <br />UP <br />SUPPLY AIR DUCT <br />DOWN <br />RETURN/EXHAUST <br />AIR DUCT UP <br />RETURN/EXHAUST AIR DUCT DOWN <br />�-�--j MANUAL VOLUME DAMPER <br />O WALL MOUNTED THERMOSTAT <br />® SUPPLY AIR DIFFUSER <br />RETURN AIR REGISTER <br />CCEILING EXHAUST FAN <br />UC 1" <br />UNDERCUT DOOR 1" ALF <br />R/A <br />RETURN AIR <br />S/A <br />SUPPLY AIR <br />O/A <br />OUTSIDE AIR <br />A R DEVOC SCHEDULE <br />MARK <br />TYPE <br />MATERIAL <br />FINISH <br />ACCESSORIES <br />I <br />BASIS OF DESIGN <br />REMARKS <br />AD-1 <br />CEILING DIFFUSER <br />24"x24" ALUMINUM <br />(2) <br />OPPOSED BLADE <br />METALAIRE <br />(1 ) <br />DAMPER <br />MODEL 5000 <br />AD-2 <br />RETURN AIR <br />ALUMINUM <br />(2) <br />OPPOSED BLADE <br />METAEAIRE <br />(1)(3) <br />REGISTER <br />DAMPER <br />MODEL RH <br />AD-3 <br />DOOR <br />ALUMINUM <br />ALUMINUM <br />FLANGE ON <br />MET ALAIRE <br />GRILLE <br />BOTH SIDES <br />MODEL DGDF <br />(1) SEE ARCHITECTURAL DRAWINGS FOR CEILING CONSTRUCTION. PROVIDE FRAME AS REQUIRED. <br />(2) BAKED ENAMEL. COLOR TO MATCH SURROUNDING COLOR. SEE ARCHITECTURAL DRAWINGS. <br />(3) PROVIDE SQUARE TO ROUND TRANSITION AS REQUIRED. <br />SPLIT SYSTEV A/C SCHEDULE <br />AIR HANDLING UNIT DATA <br />MARK <br />I- <br />AHU-1 <br />AHU-2 <br />COOLING CAPACITY <br />BTUH <br />47,000 <br />47,000 <br />SENSIBLE CAPACITY <br />BTUH <br />36,000 <br />36,000 <br />SUPPLY AIR <br />CFM <br />1,500 <br />1,550 <br />OUTSIDE AIR <br />CFM <br />300 <br />350 <br />ENTERING AIR TEMP. DB/WB <br />°F/°F <br />80/67 <br />80/67 <br />EXT. STATIC PRESSURE <br />IN. H2O <br />0.50 <br />0.50 <br />ELECTRIC HEATER NOMINAL CAPACITY <br />KW/STAGES <br />10.0/1 <br />10.0/1 <br />MOTOR <br />HP <br />3/4 <br />3/4 <br />ELECTRICAL <br />V/PH/HZ <br />208/1 /60 <br />20B/l /60 <br />UNIT POWER W/HEATER <br />MCA/MOCP <br />52.8/60 <br />52.B/60 <br />FILTER TYPE <br />- <br />1" THROWAWAY <br />1" THROWAWAY <br />BASIS OF DESIGN (1) <br />CARRIER <br />CARRIER <br />MODEL <br />- <br />FX4DNF049 <br />FX40NF049 <br />UNIT WEIGHT <br />- <br />200 LBS <br />200 LBS <br />SEER <br />- <br />14.5 <br />14.5 <br />NOTES <br />(2)(3) <br />(2)(3) <br />CONDENSING UNIT DATA <br />MARK <br />- <br />CU-1 <br />CU-2 <br />j OUTDOOR TEMPERATURE <br />°F <br />95 <br />95 <br />WEIGHT <br />LBS <br />350 <br />350 <br />ELECTRICAL <br />V/PH/HZ <br />20B/l /60 <br />20B/l /60 <br />COMPRESSOR(S) <br />LRA/RLA <br />117/21.8 <br />117/21.8 <br />MCA/HACR C.B. <br />- <br />28.5/45 <br />28.5 45 <br />BASIS OF DESIGN (1) <br />1 - <br />CARRIER <br />CARRIER <br />MODEL <br />- <br />24APA548 <br />! 24APA548 <br />NOTES <br />- <br />(4) <br />(4) <br />(1) OR APPROVED EQUAL. <br />(2) SINGLE POINT POWER CONNECTION. <br />(3) VERT'CAL UNIT. PROVIDE ANGLE IRON SUPPORT STAND WITH NEOPRENE <br />PADDING BETWEEN UNIT AND SUPPORT STAND. <br />(4) PROVIDE A MINIMUM 4" THICK CONCRATE PAD FOR UNIT TO BE SET ON. <br />PAD SHALL EXTEND 6" BEYOND UNIT ON ALL SIDES. <br />FAIN D ,HEDUL-C <br />I <br />MARK <br />F-1/2/3 <br />F-4 <br />F-5 <br />F-6/7/8 <br />CFM <br />80 <br />50 <br />150 <br />20,000 <br />EXTERNAL S.P. <br />0.25 <br />0.25" <br />0.25 <br />0.50" <br />DRIVE TYPE <br />i DIRECT <br />DIRECT <br />DIRECT <br />BELT <br />MOTOR H.P. <br />53 WATTS <br />46 WATTS <br />46 WATTS <br />5.0 <br />R.P.M. <br />1,100 <br />1,680 <br />1,680 <br />1,725 <br />ELECTRICAL <br />120/1 /60 <br />1 120/1 /60 <br />120/1 /60 <br />240/3/60 <br />BASIS OF DESIGN <br />GREENHECK <br />GREENHECK <br />GREENHECK <br />GREENHECK <br />MODEL <br />SP-A125 <br />SP-050 <br />SP-050 <br />SBE-3H48-50 <br />ACCESSORIES <br />CC, DS, BD <br />CC, DS, BD <br />CC, DS, BD <br />DS <br />NOTES <br />(1)(3) <br />(2)(3) <br />0 (5) <br />(4) <br />(1) INTERLOCK WITH LIGHT SWITCH. <br />(2) PROVIDE DEDICATED WALL SWITCH. <br />(3) CEILING MOUNTED UNIT WITH VIBRATION <br />ISOLATORS AND A UNIT MOUNTED VARIABLE <br />SPEED CONTROLLER FOR BALANCING. <br />(4) PROVIDE BACKDRAFT DAMPER, SHORT WALL <br />HOUSING, FLUSH EXTERIOR AND OSHA GUARD. <br />PROVIDE WALL MOUNTED THERMOSTAT TIED IN <br />TO ALL 3 FANS. <br />(5) INTERLOCK WITH AHU-1 AND AHU-2. <br />ACCESSORIES <br />DS - DISCONNECT SWITCH <br />BD - BACKDRAFT DAMPER <br />CC - CEILING GRILLE <br />RC ROOFC.AP <br />HVAC NOES. <br />1. ALL WORK SHALL BE ACCORDANCE WITH NEPA 90-A & B, <br />ASHRAE GUIDES, "SMACNA" DUCT CONSTRUCTION STANDARDS, <br />NEPA 101, FLORIDA STATE ENERGY CODE, 2017 FLORIDA BLINDING <br />CODE INCLUDING ALL SUPPLEMENTS AND ALL LOCAL CODES <br />HAVING JURISDICTION. <br />2. PROVIDE A P-TRAP AT CONDENSATE DRAIN LINE CONNECTION <br />A' AHU-1 2_ DRAIN LINE SHALL BE SCHEDULE 40 PVC. <br />SLOPE TO POINT OF DISCHARGE AT MINIMUM 1 /8" PER FOOT. <br />INDOOR PIPING SHALL BE INSULATED WITH MINIMUM 3/16" THICK <br />WALL "ARMAFLEX" PIPE INSULATION. <br />3. ALL EQUIPMENT SHALL BE U.L. LISTED .AND A.R.I. CERTIFIED. <br />AI_L MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER <br />SHALL BE INSTALLED WITH DISCONNECT SWITCHES AT EACH <br />PIECE OF EQUIPMENT. COORDINATE SWITCH REQUIREMENTS <br />WITH THE ELECTRICAL CONTRACTOR. IT IS THIS CONTRACTOR'S <br />RESPONSIBILITY TO COORDINATE ALL ELECTRICAL REQUIREMENTS. <br />4, DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. <br />5. ALL CEILING DIFFUSERS SHALL BE 4-WAY THROW UNLESS <br />OTHERWISE INDICATED. <br />6, ALL AIR SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED. <br />PROVIDE WRITTEN REPORT TO OWNER. <br />7. COOOD NATE LOCATION OF ALL AIR DEVICES WITH LIGHTING LAYOUT, <br />REFLECTED CEILING PLAN AND ELECTRICAL CONTRACTOR. <br />B. SUPPi_Y, RETURN AND OUTSIDE AIR DUCTWORK SHALL BE <br />FABRICATED OF 1 1 /2" TYPE 800 FIBERGLASS EQUAL TO <br />JOHNS-MANVILLE "SUPERDUCT". ALL JOINTS AND SEAMS <br />IN DUCTWORK SHALL BE SEALED PER UE 181 A. <br />DUCT SUPPORTS AND ATTACHMENT TO BUILDING STRUCTURE SHALL <br />BE AS PER SMACNA STANDARDS. DUCTBOARD INSULATION VALUE <br />SHALT_ BE MINIMUM R-6.0. MAXIMUM FLAME SPREAD INDEX SHALL <br />BE 25. MAXIMUM SMOKE -DEVELOPED INDEX SHALL BE 50. <br />9. FLEXIBLE DUCT RUNOUTS TO AIR DEVICES SHALL BE THE SAME <br />DIAMETER AS AIR DEVICE NECK SIZE. FLEXIBLE DUCT SHALE BE <br />EQUAL TO ATCO WITH A MINIMUM R-VALUE OF 6. <br />FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE <br />AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING AIR FLOW <br />RESTRICTIONS. ALL FLEXIBLE BRANCH CONNECTIONS SHALL HAVE A <br />MANUAL DAMPER INSTALLED AT THE MAIN TRUNK DUCT FOR <br />BALANCING PURPOSES. <br />10. TOILET EXHAUST DUCTWORK SHALL BE FABRICATED OF GALVANIZED <br />SHEET STEEL OR ALUMINUM THERMO-FIN WITH ALL SEAMS AND JOINTS <br />SEALED AIRTIGHT. <br />PROVIDE WALL MOUNTED MANUFACTURER'S STANDARD HEATING/COOLING <br />THERMOSTAT, SUB -BASF AND 24 VOI T CONTROL WIRING. THERMOSTAT SHALL <br />HAVE THE SAME NUMBER OF STAGES OF HEATING AND COOLING AS THE <br />MECHANICAL EQUIPMENT AND INCLUDE DUAL SETPOINTS. MOUNT 5'6" <br />ABOVE FINISHED FLOOR. INSTRUCT OWNER ON HOW TO OPERATE AND SET <br />THE HERMOSTAT AND PROVIDE DOCUMENTATION. <br />12. ALL MECHANICAL EQUIPMENT, SYSTEMS AND WORKMANSHIP SHALL BE <br />GUARANTEED FOR A PERIOD OF ONE YEAR AFTER WRITTEN ACCEPTANCE <br />BY OWNER. HVAC COMPRESSORS SHALL HAVE AN ADDITIONAL FOUR-YEAR <br />WARRANTY. <br />13. PROVIDE MINIMUM 10' CLEARANCE FROM ANY EXHAUST FAN/ROOFCAP/PLUMBING <br />VENTS TO ANY SUPPLY/MAKE-UP AIR FAN OR EQUIPMENT OUTSIDE AIR INTAKE. <br />COORDINATE WITH PLUMBING DRAWINGS PRIOR TO INSTALLATION. <br />`4. EQUIPMENT, DUCT SYSTEMS AND ANY OTHER MECHANICAL ITEMS SHALL NOT <br />BE SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM. <br />15. MECHANICAL CONTRACTOR SHALL PROVIDE ANY AND ALL SUPPLEMENTARY <br />STEEL REQUIRED FOR EQUIPMENT AND MATERIALS SUPPORT. <br />16. ANY ITEM OF EQUIPMENT REQUIRING ADJUSTMENT OR MAINTENANCE ABOVE <br />THE CEILING SHALL BE MARKED BELOW THE ITEM AT THE T-BAR WITH A <br />STICKER IDENTIFICATION THE SAME COLOR AS THE CEILING AND GRID. <br />17. REFRIGERANT COPPER LIQUID AND SUCTION LINES SHALL BE TYPE "L" SOFT <br />DRAWN AND SIZED PER MANUFACTURER'S RECOMMENDATIONS. INSULATE <br />SUCTION LINE WITH 3/4" THICK "ARMAFLEX" INSULATION. TAPE ALI_ JOINTS <br />TIGHT TOGETHER. <br />18. ALL ROOF AND WALL PENETRATIONS SHALL BE SEALED BY THEIR <br />RESPECTIVE TRADES. <br />LIGHTNING STEEL <br />CG19-014 <br />CONNELLY GROUP <br />_ CONSULTING ENGINEERS <br />C200 <br />2nd Ave South - *465 - St Petersburg, FL 33701 <br />Info®connellyeng Ineering.com <br />M813.232.8448 (F)800.698.1945 <br />r <br />www.conneIIyengIneerIng.com <br />PIM CHAPTER I <br />PROJECT <br />0 <br />Cu <br />� <br />MAAPSWMTFT <br />APERMIT AWARD Mall E iritliIWCNC TO N A L16E111E TU PROCEED OATH THE IRM <br />ANN ACT Al AUTHORITY TO MATE, CANCEL ALTER OR SET NEE ART OF THE PROVENDER <br />E T. OF WM PARER.MSHALL ERWIE OF A POUR PREVENT THEORO MR <br />=MAW <br />DATA <br />OESIONER <br />CRC <br />NTHEREAFTER IONOF THE ORE. MMTEOP�a�NOAU 1100* <br />MYAKD ULM THE WON Wllillm R RICH POUR E cmum D VAPOR ME <br />MMMR AFTER ITS RIMWRS. OR IF THE WORK METMM R SUCH POW 4 <br />NRPOEN OR AWIDEO FOR APONC OF RD MORTN AFTER THE TIE THE WORK ■ <br />DRAWN BY <br />Lug <br />QWE <br />NOW CERTIFY THAT TIDE PLANE AN INWICATENN COMPLY RTTH THE <br />NMEEM M OF THE APPUCAiF RIE!•ER CM RPEfRP® DE THE TILE EMR <br />JJC <br />' CHECKED <br />C3 <br />CRC <br />o <br />J <br />IL <br />I- <br />W <br />LU <br />= <br />U) <br />F <br />s <br />a <br />FBC <br />c <br />C ! <br />6TH EDITION <br />m <br />" <br />(2017) <br />LU <br />Q <br />CONNELLY GROUP CONSULTING ENGINEERS AND THEIR <br />AGENTS, RESERVES THE RIGHT TO REVISE DETAILS <br />LU <br />SHOWN HERE AT SUCH TIME AS REVISIONS WILL RESULT <br />IN ENGINEERING OR ECONOMIC IMPROVEMENTS. THESE <br />N <br />DRAWINGS ARE GRAPHIC REPRESENTATION OF A DESIGN <br />W <br />CONCEPT, ACTUAL DETAILS SUBJECT TO FIELD <br />VERIFICATION. <br />W <br />x <br />�N <br />i <br />I <br />I <br />I <br />I <br />! <br />I <br />� <br />i <br />I <br />I <br />I <br />J <br />I <br />W <br />Uj <br />N <br />qqT <br />C3 Ln <br />cn <br />Q <br />I <br />C3 <br />>EEA LL <br />Z <br />W <br />� <br />�i <br />Z <br />U <br />Q "J <br />E� <br />,J <br />C3 <br />Q <br />IL <br />c <br />a. <br />3 <br />z <br />O W <br />L-_ <br />DRAWING SETS <br />REVIEW III (CM • 12.04.19 (0E1 <br />BK) 00.00.00 <br />PERMIT WU REVIEW) 08.01LI3 <br />I <br />I <br />PROFESSIONAL SEAL <br />DATE SEALED: SEPTEMBER S, 2019 <br />� <br />®®®e0901BapBp®® <br />®®®�®�o �� • <br />c©®®®®®® <br />° <br />V%CEP��'°° <br />S� <br />6�i <br />n°R. <br />®®pppoloaaae®® <br />LV <br />CHRISTOPHER R. CONNELLY, PE <br />PE-FL83886 i CA -FL 28841 <br />-� <br />MECHANICAL NOTES AND <br />�I <br />SCHEDULES <br />_' <br />MOOO <br />