My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (41)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (41)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:05:10 AM
Creation date
2/18/2025 3:18:56 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
Ryman Construction
Building Plans - Permit #
14830
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHAUST AIR <br />OUTSIDE AIR <br />INPUT/OUTPUT SUMMARY (VAV - COOLING/HUMIDIFICATION AHU) <br />EQUIPMENT MOUNTED PANELS <br />0 <br />BINARY <br />INPUT <br />0 <br />BINARY <br />OUTPUT <br />0 <br />ANALOG <br />INPUT <br />Ao <br />ANALOG <br />OUTPUT <br />EQUIPMENT: <br />SOUTH: AHU-1 <br />NORTH: AHU-2 <br />OCUPANCY SCHEDULE: <br />OCCUPIED: 7AM - 6PM M-F (ADJ) <br />UNOCCUPIED: OTHERWISE +HOLIDAYS <br />POINT <br />ID <br />POINT DESCRIPTION <br />1 <br />SUPPLY FAN STATUS <br />X <br />2 <br />RETURN/EXHAUST FAN STATUS <br />X <br />3 <br />EXHAUST DAMPER STATUS <br />X <br />4 <br />SUPPLY AIR RELATIVE HUMIDITY <br />X <br />5 <br />FILTER STATUS <br />X <br />6 <br />SUPPLY AIR SMOKE DETECTOR <br />X <br />7 <br />RETURN AIR SMOKE DETECTOR <br />X <br />8 <br />RETURN/EXHAUST AIR RELATIVE HUMIDITY <br />X <br />9 <br />RETURN/EXHAUST FAN VFD CONTROL POINT ADJ <br />X <br />10 <br />RETURN/EXHAUST FAN START/STOP <br />X <br />11 <br />RELIEF EXHAUST DAMPER OPEN/CLOSE <br />X <br />12 <br />RETURN/EXHAUST FAN STATUS <br />X <br />13 <br />RETURN/EXHAUST FAN VFD FAULT <br />X <br />14 <br />RETURN/EXHAUST FAN START/STOP <br />X <br />15 <br />RETURN/EXHAUST FAN VFD CONTROL POINT ADJ <br />X <br />16 <br />LIQUID LINE SELENOID VALVE STATUS <br />X <br />17 <br />LIQUID LINE SELENOID VALVE OPEN/CLOSE <br />X <br />18 <br />HOT GAS SELENOID VALVE STATUS <br />X <br />19 <br />HOT GAS SELENOID VALVE OPEN/CLOSE <br />X <br />20 <br />SPACE RELATIVE HUMIDITY <br />X <br />21 <br />OUTSIDE AIR DRY BULB <br />X <br />22 <br />OUTSIDE AIR RELATIVE HUMIDITY <br />X <br />23 <br />RETURN/EXHAUST AIR DRY BULB <br />X <br />24 <br />ERW LEAVING SUPPLY AIR DRY BULB <br />X <br />25 <br />SUPPLY AIR DRY BULB <br />X <br />26 <br />SUPPLY DUCT STATIC PRESSURE <br />X <br />27 <br />ENERGY RECOVERY WHEEL START/STOP <br />X <br />28 <br />ENERGY RECOVERY WHEEL STATUS <br />X <br />29 <br />ERW ENTERING EXHAUST AIR DRY BULB <br />X <br />30 <br />ERW LEAVING EXHAUST AIR DRY BULB <br />X <br />31 <br />OA DAMPER STATUS <br />X <br />32 <br />DIGITAL SCROLL START/STOP <br />X <br />33 <br />DIGITAL SCROLL MODULATE <br />X <br />34 <br />DIGITAL SCROLL STATUS <br />X <br />35 <br />REVERSING VALVE HEAT/COOL STATUS <br />X <br />36 <br />REVERSING VALVE HEAT/COOL CHANGEOVER <br />X <br />37 <br />RETURN DUCT STATIC PRESSURE <br />X <br />38 <br />SPACE DRY BULB TEMPERATURE <br />X <br />39 <br />OA DAMPER OPEN/CLOSE <br />X <br />Grand total: 39 <br />30 29 0[—,3] 15 8 23 00 <br />11 T T 2❑ 10 F7] RH T <br />VFD SD <br />17 <br />ES RETURN/ <br />EXHAUST AIR <br />[28] <br />[3] <br />27 <br />21 22 24 a Ag <br />O O O <br />T RH T 12 14 <br />H L <br />VFD <br />SUPPLY AIR <br />C9�■C7o <br />GENERAL NOTES: <br />CONTROL CONTRACTOR SHALL PROVIDE WIRING AND <br />INSTALLATION FOR REMOTE MOUNTED CONTROL DEVICES. <br />ALL SETPOINTS SHALL BE ADJUSTABLE. <br />PID CONTROL LOOPS SHALL HAVE PROGRAMMABLE <br />PROPORTIONAL, INTEGRAL AND DERIVATIVE COEFFICIENTS. <br />THE AIR VALVE WILL MODULATE USING A PID CONTROL LOOP. <br />THE ELECTRIC REHEAT CONTROLLER WILL MODULATE USING A <br />SEPARATE PID CONTROL LOOP. <br />PACKAGED ROOFTOP UNIT: <br />SINGLE ZONE, DX COOLING W/ HEAT PUMP, HOT GAS RE -HEAT AND <br />LIQUID SUB COOLING, VARIABLE VOLUME, ECONOMIZER, ROOF <br />MOUNTED AIR HANDLING UNIT. SYSTEM MODES INCLUDE COOLING, <br />DEHUMIDIFICATION, ECONOMIZER AND HEAT PUMP MODE. <br />SCHEDULE FOR OCCUPIED AND UNOCCUPIED CONDITIONS IS <br />AVAILABLE. INCLUDE OPTIMUM START AND SUPPLY TEMPERATURE <br />RESET. <br />ECONOMIZER MODE: IF OUTSIDE AIR TEMPERATURE IS GREATER <br />THAN 45°F, ENTHALPY WHEEL TURNS OFF. <br />DEHUMIDIFICATION MODES: LIQUID SUB -COOLING FOR COOLING <br />AND DEHUMIDIFICATION AND HOT GAS REHEAT FOR LOW DEMAND <br />LOAD AND DEHUMIDIFICATION. EACH CIRCUIT CAN OPERATE IN <br />EACH OF THE THREE MODES INDEPENDENTLY. ZONE <br />THERMORSTATS IN CONJUNCTION WITH BOTH RETURN AIR RH <br />SENSOR AND REPORTED RH FROM ZONE PRESSURE <br />CONTROLLER, WHICHEVER HIS HIGHER, DETERMINE THE MODE OF <br />OPERATION. <br />RTU OPERATES AT 100% OUTSIDE AIR. IF OUTDOOR ENTHALPY <br />SENSOR IS LESS THAN 20.0 BTU/LB (ADJUSTABLE), THE UNIT SHALL <br />GO INTO ECONOMIZER MODE. <br />RTU SUPPLY FAN WITH VFD VARIES AIRFLOW IN UNOCCUPIED <br />MODE. SUPPLY FAN OPERATES AT COSTANT FLOW DURING <br />OCCUPIED MODE. <br />THE RTU EXHAUST FAN WITH VFD MODULATE RETURN/EXHAUST <br />AIR FLOW TO MAINTAIN A DUCT STATIC PRESSURE SET POINT <br />LOCATED TWO-THIRDS OF THE WAY UPSTREAM IN THE MAIN <br />RETURN TRUNK. <br />SUPPLY TEMPERATURE RESET SHALL UTILIZE TRIM AND RESPOND <br />LOGIC WITHIN THE RANGE 55 to 70OF TO MINIMIZE THE AMOUNT OF <br />ZONE RE -HEAT WHEN OPERATING IN COOLING MODE. THE SUPPLY <br />AIR TEMPERATURE RESETS NO MORE FREQUENT THAN AT 5 MIN <br />INTERVAL. WHEN BOTH ZONES CALL FOR HEATING, THE RTU <br />REFRIGERATION SYSTEM OPERATES IN HEAT PUMP MODE WITH <br />THE AIR SUPPLY TEMPERATURE SET AS NECESSARY TO MINIMIZE <br />THE AMOUNT OF ZONE RE -HEAT. <br />ENTHALPY RECOVERY WHEEL (ERW) OPERATES AT CONSTANT <br />SPEED AND TURNS OFF WHEN RTU ENTERS ECONOMIZER MODE <br />AND ERW SUPPLY AIR TEMPERATURE IS LESS THAN 48 OF (ADJ) TO <br />AVOID TOO HIGH ERW SUPPLY AIR TEMPERATURE INCREASE <br />RESULTING IN UNECESSARY MECHANICAL COOLING. ERW ALSO <br />TURNS OFF IF THE RTU EXHAUST FAN SHUTS DOWN. <br />A DIGITAL SCROLL COMPRESSOR MODULATES SYSTEM CAPACITY <br />TO MEET SUPPLY AIR TEMPERATURE SETPOINT. <br />SMOKE DETECTORS SHALL STOP THE FAN WHEN ALARMED. HIGH <br />STATIC PRESSURE SWITCH SHALL STOP THE FAN WHEN ALARMED. <br />38 20 <br />SPACE SENSOR <br />LOCATED RH SENSORS AS FOLLOWS: <br />RETURN DUCT <br />SPACE (MICROLAB ROOM & QC LAB ROOM) <br />UTILIZE VAV BOX DATA FOR SUPPLY AIR TEMPERATURE RESET <br />RETURN AIR <br />25 O <br />a <br />T RH <br />SD <br />LIJI.AIC JIAI Il. <br />PROBE 2/3 DOWN <br />DUCT RUN. <br />INPUT/OUTPUT SUMMARY (VARIABLE VOLUME TERMINAL <br />BOX) <br />EQUIPMENT MOUNTED PANELS <br />0 <br />BINARY <br />INPUT <br />0 <br />BINARY <br />OUTPUT <br />0 <br />ANALOG <br />INPUT <br />Ao <br />ANALOG <br />OUTPUT <br />POINT <br />ID <br />POINT DESCRIPTION <br />1 <br />PRIMARY AIR FLOW STATION <br />X <br />2 <br />ROOM TEMPERATURE <br />X <br />3 <br />USER TEMPERATURE ADJUSTMENT <br />X <br />4 <br />ROOM PRESSURE <br />X <br />5 <br />RELATIVE HUMIDITY <br />X <br />6 <br />OCCUPANCY OVERRIDE SWITCH <br />X <br />7 <br />PRIMARY AIR DAMPER MODULATE <br />X <br />8 <br />ELECTRIC REHEAT MODULATE (SCR) <br />X <br />9 <br />DISCHARGE TEMPERATURE <br />X <br />10 <br />RETURN AIR FLOW STATION <br />X <br />11 <br />RETURN AIR TEMPERATURE <br />X <br />12 <br />RETURN AIR DAMPER MODULATE <br />X <br />Grand total: 12 <br />SUPPLY AIR <br />FROM RTU <br />A7 <br />TO RTU <br />ZONE PRESSURE CONTROLLER, <br />TSI RPC30, WITH PRESSURE, <br />TEMPERATURE AND HUMIDITY <br />SENSORS AND TEMPERATURE <br />SETPOINT (ADJ.) <br />AND OCCUPANCY OVERRIDE <br />/a . <br />11 <br />Aio <br />SUPPLY AIR <br />RETURN AIR <br />GENERAL NOTES: <br />CONTROL CONTRACTOR SHALL PROVIDE WIRING AND INSTALLATION FOR REMOTE MOUNTED CONTROL <br />DEVICES. <br />ALL SETPOINTS SHALL BE ADJUSTABLE. <br />PID CONTROL LOOPS SHALL HAVE PROGRAMMABLE PROPORTIONAL, INTEGRAL AND DERIVATIVE COEFFICIENTS. <br />THE AIR VALVE WILL MODULATE USING A PID CONTROL LOOP. <br />THE ELECTRIC REHEAT CONTROLLER WILL MODULATE USING A SEPARATE PID CONTROL LOOP. <br />OCCUPIED: <br />THERMOSTAT SETPOINT: 70 OF HEATING AND 75' COOLING. <br />VARIABLE VOLUME TERMINAL BOX WITH ELECTRIC REHEAT <br />THE SINGLE DUCT VARIABLE VOLUME TERMINAL UNIT DELIVERS A CONSTANT AIRFLOW TO THE SPACE DURING <br />OCCUPIED MODE TO MEET SPACE LOAD AND ACHIEVE A MINIMUM OF 10 AIR CHANGES, WHICHEVER IS GREATER. <br />THE VAV TERMINAL ELECTRIC REHEAT COILS ARE UNDER CONTROL OF THE ZONE'S PRESSURE CONTROLLER <br />PROVIDED WITH TEMPERATURE SENSOR (THERMOSTAT). <br />HEATING: ON A DECREASE IN SPACE TEMPERATURE BELOW HEATING SETPOINT (ADJUSTABLE), ELECTRIC <br />REHEAT COIL WITH SCR MODULATES TO MAINTAIN TEMPERATURE SETPOINT. <br />THE ZONE REHEAT COILS ARE MONITORED AND THE SUPPLY AIR TEMPERATURE IS INCREASED UNTIL THE <br />REHEAT COIL OF THE ZONE WITH LEAST HEATING LOAD MODULATES OFF WHILE MAINTAINING SPACE <br />TEMPERATURE SET POINT. REHEAT FOR OTHER ZONE ALSO MODULATE ACCORDINGLY TO MAINTAIN <br />TEMPERATURE SETPOINT. <br />COOLING: ON AN INCREASE IN SPACE TEMPERATURE ABOVE COOLING SETPOINT (ADJUSTABLE) THE RTU <br />SYSTEM SHALL BE SIGNALED TO ADJUST THE COOLING AIR SUPPLY TEMPERATURE SETPOINT. ZONE REHEAT <br />SHOULD BE OFF. <br />A TEMPERATURE CONTROL DEADBAND OF +/- 5°F (ADJ) SHALL BE SET TO ELIMINATE EXCESSIVE CYCLING OF <br />HEATING AND COOLING. <br />RETURN AIR DAMPER: <br />THE AIRFLOW DIFFERENTIAL BETWEEN SUPPLY AIR AND RETURN (AIR BALANCE) IS DETERMINED BY THE <br />PRESSURE CONTROLLER. FAST ACTUATING DAMPERS MODULATE DAMPER POSITION TO VARY RETURN AIR AND <br />MAINTAIN PRESSURE SETPOINTS OF +0.01" W.C. POSITIVE PRESSURE FOR QA LAB RELATIVE TO THE <br />WAREHOUSE AND +0.02" W.C. POSITIVE PRESSURE FOR MICROLAB RELATIVE TO THE WAREHOUSE. <br />UPON MANUAL ACTIVATION OF CHEMICAL FUME EXHAUST HOOD (W/ BYPASS), THE MOTORIZED DAMPER OPENS <br />AND EXISTING EXHAUST FAN ACTIVATES TO OPERATE AT FUME HOOD'S MAXIMUM COSTANT FLOW. <br />UPON MANUAL ACTIVATION OF AUTOCLAVE EXHAUST HOOD, THE MOTORIZED DAMPER OPENS AND THE <br />EXHAUST FAN WITH ECM ACTIVATES AND OPERATES AT USER ADJUSTABLE AIRFLOW UP TO 500 CFM. AN <br />ADJUSTABLE TIMER AUTOMATICALLY SHUTS DOWN THE FAN AND CLOSES THE MOTORIZED EXHAUST DAMPER. <br />UPON ACTIVATION OF LAB EQUIPMENT EXHAUST, THE RETURN AIR DAMPER IS CAPABLE TO MODULATE DOWN TO <br />LOW FLOW AND WILL CLOSE SHUT AS NECESSARY TO MAINTAIN SPACE PRESSURIZATION. <br />WHEN OCCUPANCY OVERRIDE SWITCH IS ENERGIZED, THE TERMINAL BOX CONTROL SHALL CHANGE TO <br />OCCUPIED MODE FOR 2HRS (ADJUSTABLE). <br />THERMOSTAT SETBACK SETPOINT: 65 OF HEATING AND 780 COOLING. <br />ZONE TERMINAL SUPPLY BOX: SUPPLY AIRFLOW TO THE SPACE IS MODULATED FROM ITS MINIMUM AIRFLOW TO <br />MEET TEMPERATURE SETPOINT. MINIMUM AIR FLOW IS EQUIVALENT TO 5 AIR CHANGES AS FOLLOWS: <br />MICROLAB = 215 CFM <br />QA LAB = 520 CFM <br />THE ZONE REHEAT MODULATES TO MAINTAIN TEMPERATURE SETPOINT. RTU SUPPLY WILL MODULATE TO <br />MAINTAIN DUCT STATIC PRESSURE SETPOINT TWO-THIRDS FROM RTU DOWNSTREAM IN THE MAIN SUPPLY <br />TRUNK. <br />ZONE RETURN DAMPER: DAMPER MODULATES TO TRACK THE SUPPLY AIR TO ACHIEVE THE REQUIRED AIR <br />BALANCE UNDER THE CONTROL OF THE PRESSURE CONTROLLER AND MAINTAIN ROOM PRESSURIZATION. <br />PRESSURE SETPOINTS ARE +0.01" W.C. POSITIVE PRESSURE FOR QA LAB RELATIVE TO THE WAREHOUSE AND + <br />0.02" W.C. POSITIVE PRESSURE FOR MICROLAB RELATIVE TO THE WAREHOUSE. RTU EXHAUST FANS WILL <br />MODULATE TO MAINTAIN DUCT STATIC PRESSURE SETPOINT TWO-THIRDS FROM RTU UPSTREAM IN THE MAIN <br />RETURN TRUNK. <br />RELATIVE HUMIDITY WILL BE MONITORED AND RTU WILL BE SIGNALED TO ENTER DEHUMIDIFICATION MODE <br />WHEN EITHER PRESSURE CONTROLLER WITH RH SENSOR IN THE SPACE OR RH SENSOR IN THE RETURN <br />DUCT REPORT ABOVE 55% RH. <br />UPON ACTIVATION OF LAB EQUIPMENT EXHAUST, THE SYSTEM SWITCHES TO OCCUPIED MODE. <br />INPUT/OUTPUT SUMMARY (LAB EQUIPMENT EXHAUST) <br />EQUIPMENT MOUNTED PANELS <br />[:fl0o <br />BINARY <br />INPUT <br />BINARY <br />OUTPUT <br />O <br />ANALOG <br />INPUT <br />Ao <br />ANALOG <br />OUTPUT <br />POINT <br />ID <br />POINT DESCRIPTION <br />1 <br />AUTOCLAVE EXHAUST FAN DAMPER OPEN/CLOSE <br />X <br />2 <br />AUTOCLAVE EXHAUST FAN DAMPER STATUS <br />X <br />3 <br />AUTOCLAVE EXHAUST FAN STATUS <br />X <br />4 <br />AUTOCLAVE EXHAUST FAN START/STOP <br />X <br />5 <br />AUTOCLAVE EXH FAN ECM MOTOR CTRL ADJ <br />X <br />6 <br />FUME HOOD EXH. FAN DAMPER OPEN/CLOSE <br />X <br />7 <br />FUME HOOD EXHAUST FAN DAMPER STATUS <br />X <br />8 <br />FUME HOOD EXHAUST FAN STATUS <br />X <br />9 <br />FUME HOOD EXHAUST FAN START/STOP <br />X <br />10 <br />ROOM TEMPERATURE <br />X <br />11 <br />USER TEMPERATURE ADJUSTMENT <br />X <br />Grand total: 11 <br />0 n <br />EHXUAST AIR <br />EF E <br />EX S [7] <br />MEP / FP Engineer <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />FROM CHEMICAL EHXUAST AIR <br />FUME HOOD <br />Design Architect <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />GENERAL NOTES: <br />CONTROL CONTRACTOR SHALL PROVIDE WIRING AND INSTALLATION FOR <br />REMOTE MOUNTED CONTROL DEVICES. <br />AUTOCLAVE EXHAUST FAN: <br />AUTOCLAVE EHXUAST FAN IS EQUIPPED WITH VARIABLE SPEED ECM MOTOR, <br />AND SHALL BE FACTORY PRE-PROGRAMMED FOR AIRFLOW UP TO 500 CFM <br />AND SOFT START AND SOFT STOP CAPABILITY. <br />UPON MANUAL ACTIVATION, THE INTERLOCKED LOW LEAKAGE EXHAUST <br />DAMPER OPENS BEFORE ECM FAN MOTOR STARTS. FAN MOTOR GRADUALLY <br />RAMPS UP (SOFT START) AT A CONSTANT RATE OF 80 RPM UP TO USER <br />ADJUSTABLE SPEED SETTING. <br />EXHAUST FAN OPERATES FOR THE DURATION OF TIME INTERVAL SET AT THE <br />TIMER (ADJUSTABLE) AND RAMPS DOWN (SOFT STOP) AT A CONSTANT RATE <br />OF 80 RPM BEFORE SHUTTING OFF. EXHAUST DAMPER CLOSES TIGHT SHUT. <br />CHEMICAL FUME HOOD EXHAUST FAN: <br />UPON MANUAL ACTIVATION, THE INTERLOCKED LOW LEAKAGE EXHAUST <br />DAMPER OPENS BEFORE FAN MOTOR STARTS. FAN MOTOR CONTINUOUSLY <br />OPERATES UNTIL MANUALLY SHUT DOWN. EXHAUST DAMPER CLOSES SHUT <br />TIGHT. <br />WALL MOUNTED GREENHECK VAR[ -GREEN REMOTE DIAL <br />CONTROL WITH SEPARATE DIGITAL ADJUSTABLE TIMER. <br />ALTERNATE: WALL MOUNTED COMPATIBLE 0-10V SIGNAL <br />MOTOR SPEED CONTROL WITH INTEGRATED TIMER AND <br />ODIGITAL DISPLAY AND WITH ENGINEER'S APPROVAL. <br />FROM ADJ MOTOR <br />10 <br />AUTOCLAVE SPEED <br />EXHAUST <br />HOOD TIMER (ADJ) 11 <br />ES <br />Nestle Waters North America <br />Nestle Waters North America <br />4330 20th Street <br />Zephyrtiills, Florida 33542-6703 <br />972.462.3663 <br />Festld <br />Waters <br />C. <br />� A <br />1 <br />F! <br />.4� m <br />4 <br />09.18.2013 <br />ISSUE FOR PERMIT <br />3 <br />09.11.2013 <br />ISSUE FOR BIDS <br />2 <br />09.03.2013 <br />CD REVIEW PACKAGE <br />1 <br />08.16.2013 <br />DD REVIEW PACKAGE <br />NO. <br />DATE <br />REVISIONS/ISSUANCES <br />PSTEIN <br />5i <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: <br />12386 <br />PROJECT MANAGER: <br />JK <br />ARCH/ENG: <br />LK <br />SCALE: <br />1/8" =1'-0" <br />DRAWN BY: <br />JK <br />CHECKED BY: <br />LK <br />MECHANICAL <br />CONTROLS <br />M-103 <br />2.44% <br />A. Epstein and Sons inWrarional, Inc. All rights reserved. <br />