Laserfiche WebLink
UNDERGROUND PLUMBING SYSTEMS <br />PART 1 - GENERAL <br />1.01 SUMMARY <br />A. RELATED DOCUMENTS: PROVISIONS OF THE CONTRACT, INCLUDING CONDITIONS OF THE CONTRACT, <br />DRAWINGS AND DIVISION 1 - GENERAL REQUIREMENTS OF THE SPECIFICATION, APPLY TO THIS SECTION. <br />B. DESCRIPTION: UNDERGROUND PLUMBING SYSTEMS ARE INDICATED BY CONTRACT DOCUMENTS AND INCLUDE <br />WORK NECESSARY AND INCIDENTAL TO COMPLETION AND PERFORMANCE OF THE WORK. <br />C. INCLUDED: UNDERGROUND PLUMBING SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: <br />1. DOMESTIC WATER SYSTEM WITH SERVICE FROM 5 FEET OUTSIDE BUILDING TO INSIDE THE BUILDING AS <br />INDICATED ON DRAWINGS. <br />2. SANITARY DRAIN SYSTEM INSIDE BUILDING AND EXTENDING TO A POINT 5 FEET OUTSIDE BUILDING AS <br />INDICATED ON DRAWINGS. <br />3. OPEN HUB DRAINS. <br />4. CLEANOUTS. <br />5. SLEEVES. <br />D. RELATED WORK: <br />1. ABOVEGROUND PLUMBING. <br />2. PLUMBING FIXTURES. <br />1.02 SYSTEM DESCRIPTION <br />A. CODES AND STANDARDS: MEET REQUIREMENTS OF FOLLOWING, EXCEPT TO EXTENT OF MOST STRINGENT <br />REQUIREMENTS OF CONTRACT DOCUMENTS AND OF CODES AND REGULATIONS OF PUBLIC AUTHORITIES <br />BEARING ON PERFORMANCE OF THE WORK. <br />1. FLORIDA PLUMBING CODE, CURRENT EDITION WITH REVISIONS. <br />2. FLORIDA BUILDING CODE, CURRENT EDITION WITH REVISIONS. <br />1.03 QUALITY ASSURANCE <br />A. REGULATORY REQUIREMENTS: COMPLY WITH WATER AND SEWER REGULATIONS OF AUTHORITIES BEARING ON <br />PERFORMANCE OF THE WORK, WHICH REQUIRE PRODUCTS USED FOR DRAINAGE AND DOMESTIC WATER <br />SYSTEMS BE SELECTED FROM LISTS SPECIFIED IN REGULATIONS OF PUBLIC AUTHORITIES BEARING ON <br />PERFORMANCE OF THE WORK, AND WHICH COMPLY WITH CERTAIN PUBLISHED STANDARDS OR CODES, AND <br />THAT PRODUCTS BE USED AS INTENDED. <br />B. MANUFACTURER QUALIFICATIONS: MANUFACTURER SHALL HAVE 5 YEARS MINIMUM DOCUMENTED EXPERIENCE <br />IN DESIGN, PRODUCTION, FABRICATION, INSTALLATION AND MAINTENANCE OF TYPE AND QUALITY REQUIRED <br />FOR WORK. UPON REQUEST, PROVIDE PROOF OF QUALIFICATIONS. <br />C. INSTALLER QUALIFICATIONS: INSTALLER SHALL HAVE 5 YEARS MINIMUM DOCUMENTED EXPERIENCE IN DESIGN, <br />ENGINEERING, DETAILING, FABRICATION, INSTALLATION AND MAINTENANCE OF TYPE AND QUALITY REQUIRED <br />FOR WORK. INSTALLER SHALL MAINTAIN AND HAVE MAINTAINED A SERVICE CENTER WITH PARTS INVENTORY <br />AND MANUFACTURER TRAINED PERSONNEL FOR 5 YEARS MINIMUM. UPON REQUEST, PROVIDE PROOF OF <br />QUALIFICATIONS. <br />1.04 SUBMITTALS <br />A. PRODUCT DATA: SUBMIT PRODUCT SPECIFICATIONS, TECHNICAL DATA, STANDARD DETAIL DRAWINGS AND <br />INSTALLATION INSTRUCTIONS OF MANUFACTURER FOR EACH PRODUCT. INCLUDE PUBLISHED DATA, CERTIFIED <br />CONFORMANCE REPORT OF CERTIFIED LABORATORY TEST REPORT OF MANUFACTURER SUBSTANTIATING EACH <br />PROPOSED PRODUCT MEETS REQUIREMENTS OF CONTRACT DOCUMENTS. <br />B. SHOP DRAWINGS: SUBMIT ACCURATELY SCALED DIMENSIONED SHOP DRAWINGS INDICATING RELATIONSHIPS <br />TO ASSOCIATED PIPING AND STRUCTURES FOR EACH PIPING SYSTEM, FITTINGS AND DRAINS SHOWING PIPE <br />SIZES, LOCATIONS, ELEVATIONS AND SLOPES OF HORIZONTAL RUNS, FITTINGS, ACCESSORIES AND <br />CONNECTIONS. <br />C. RECORD DOCUMENTS: SUBMIT RECORD DRAWINGS AND SHOP DRAWINGS SHOWING LOCATION AND <br />ELEVATIONS OF UNDERGROUND PLUMBING PIPING. <br />1.05 PRODUCT HANDLING <br />A. RETAIN FACTORY APPLIED PLASTIC END CAPS ON EACH LENGTH OF PIPE AND TUBE. MAINTAIN END CAPS <br />THROUGH SHIPPING AND HANDLING TO PREVENT PIPE END DAMAGE AND ELIMINATE DIRT AND MOISTURE FROM <br />ENTERING INSIDE OF PIPE AND TUBE. <br />B. WHERE POSSIBLE, STORE PIPE AND TUBE INSIDE AND PROTECT FROM WEATHER. WHEN NECESSARY TO STORE <br />PIPE AND TUBE OUTSIDE, ELEVATE ABOVE GROUND AND ENCLOSE WITH DURABLE, WATERPROOF WRAPPING. <br />1.06 WARRANTY <br />A. GENERAL: WARRANTY WORK MEETING PROVISIONS OF CONDITIONS OF THE CONTRACT, EXCEPT WARRANTY <br />SHALL INCLUDE ADDITIONAL REQUIREMENTS SPECIFIED IN THIS ARTICLE. <br />B. FURNISH MANUFACTURER WARRANTIES. <br />PART 2-PRODUCTS <br />2.01 PIPE AND FITTINGS <br />A. DOMESTIC WATER SERVICE - 3 INCHES AND LARGER: <br />1. PIPE: MECHANICAL JOINT DUCTILE IRON COATED WITH 8 MIL POLYETHYLENE MEETING REQUIREMENTS OF <br />ANSI A21.11, ANSI A21.50 AND ANSI A21.51 WITH CEMENT LINING MEETING REQUIREMENTS OF ANSI A21.4 OF <br />CLASS REQUIRED BY CODE AND DEPTH OF BURY. <br />2. FITTINGS: MECHANICAL JOINT FITTINGS MEETING REQUIREMENTS OF ANSI A21.10 AND ANSI A21.11. <br />B. DOMESTIC WATER SERVICE - 2-1/2 INCHES AND SMALLER: <br />1. PIPE: COPPER TUBING, SEAMLESS TYPE K, EITHER HARD DRAWN STRAIGHT LENGTHS OR SOFT ANNEALED <br />COILS MEETING REQUIREMENTS OF ASTM B88 AND ANSI H23.1. <br />2. FITTINGS: <br />a. SOLDERED OR BRAZED, WROUGHT COPPER MEETING REQUIREMENTS OF ANSI B16.22. <br />b. CAST BRONZE MEETING REQUIREMENTS OF ANSI B16.18, 200 PSI. CAST BRONZE FLARED FITTINGS SHALL <br />MEET REQUIREMENTS OF ANSI B16.26. <br />3. JOINTS: LEAD FREE SOLDER. <br />C. DRAINS -SANITARY: <br />1. PIPE: CAST IRON, SERVICE WEIGHT, BELL AND SPIGOT, SINGLE HUB, ASPHALT COATED, WITH NEOPRENE <br />RUBBER GASKETS MEETING REQUIREMENTS OF ASTM A74, CS-188 AND WW-P-401 C. <br />1.1. JOINTS: RESILIENT NEOPRENE RUBBER COMPRESSION GASKET MEETING REQUIREMENTS OF ASTA <br />C425. <br />2. CORROSION RESISTANT, NON-FLAMMABLE SCHEDULE 40 POLYVINYL CHLORIDE (PVC) PIPE AND DRAINAG <br />FITTINGS JOINED WITH SOLVENTS MEETING REQUIREMENTS OF ASTM D2665 AND ASTM D2855. PVC NOT <br />ALLOWED IN RETURN AIR PLENUM APPLICATIONS. <br />3. M PIPE: TYPE L HARD TEMPER, COPPER TUBING IN STRAIGHT LENGTHS, MEETING REQUIREMENTS OF AS <br />B88, <br />3.1. FITTINGS: SLEEVE TYPE WITH SOLDER COMPLETELY FILLING JOINTS BY CAPILLARY ACTION. CAST <br />BRASS FILINGS SHALL CONFORM TO ANSI B16.18. WROUGHT COPPER FITTINGS SHALL HAVE WALL <br />THICKNESS AT LEAST EQUAL TO THE TUBE AND CONFORM TO ANSI B16.22. <br />D. VENT <br />1. PIPE: TYPE L HARD TEMPER, COPPER TUBING IN STRAIGHT LENGTHS, MEETING REQUIREMENTS OF ASTA <br />B88. <br />1.1. FITTINGS: SLEEVE TYPE WITH SOLDER COMPLETELY FILLING JOINTS BY CAPILLARY ACTION. CAST <br />BRASS FILINGS SHALL CONFORM TO ANSI B16.18. WROUGHT COPPER FITTINGS SHALL HAVE WALL <br />THICKNESS AT LEAST EQUAL TO THE TUBE AND CONFORM TO ANSI B16.22. <br />2. CORROSION RESISTANT, NON-FLAMMABLE SCHEDULE 40 POLYVINYL CHLORIDE (PVC) PIPE AND DRAINAG <br />FITTINGS JOINED WITH SOLVENTS MEETING REQUIREMENTS OF ASTM D2665 AND ASTM D2855. PVC NOT <br />ALLOWED IN RETURN AIR PLENUM APPLICATIONS. <br />2.02 FLOOR DRAINS (FD) <br />A. GENERAL: DRAINS SHALL HAVE DEEP SEAL P-TRAPS, EXCEPT WHERE OTHERWISE INDICATED ON DRAWINGS. <br />DRAINS SHALL HAVE THREADED, COMPRESSION JOINT OUTLET OR CAULK OUTLET. <br />B. ACCEPTABLE MANUFACTURERS: <br />1. JAY R. SMITH MFG. CO. <br />2. JOSAM COMPANY. <br />3. WADE. <br />4. ZURN. <br />C. FINISHED AREAS: <br />1. GENERAL: CAST IRON BODY WITH FLASHING COLLAR, ADJUSTABLE NICKEL BRONZE ROUND TOP. <br />2.03 OPEN HUB DRAINS (OHD) <br />A. PROVIDE WITH DEEP SEAL P-TRAPS AND GRATING SET INSIDE HUB. <br />2.04 CLEANOUTS <br />A. ALL PARTS OF PLUMBING DRAINAGE SYSTEM SHALL BE ACCESSIBLE FOR RODDING. <br />B. CLEANOUT EXTENSIONS SHALL CONSIST OF A CAST IRON Y BRANCH AND 1/8 BEND IN DRAIN LINE WITH A CAST <br />IRON SOIL PIPE EXTENSION TERMINATING IN CAST IRON COUNTERSUNK CLEANOUT PLUG AND TOP SET FLUSH <br />WITH FLOOR. <br />C. UNDERGROUND DRAIN LINE CLEANOUTS IN LINES, UNLESS OTHERWISE INDICATED ON DRAWINGS: <br />1. 4 INCHES IN DIAMETER OR LESS: CLEANOUTS SAME SIZE AS PIPES SERVED AND NOT MORE THAN 50 FEE' <br />APART. <br />2. 5 INCHES THRU 8 INCHES IN DIAMETER: 6 INCH CLEANOUTS AND NOT MORE THAN 100 FEET APART. <br />3. 10 INCHES AND LARGER: 8 INCH CLEANOUTS AND NOT MORE THAN 100 FEET APART. <br />D. FINISHED AREAS: <br />1. GENERAL: LABELED SANITARY OR STORM AS APPLICABLE, CAST IRON CLEANOUT BODY, BRONZE <br />COUNTERSUNK CLOSURE PLUG, ADJUSTABLE SCORIATED SECURED NICKEL BRONZE COVER. <br />2. TILED FLOORS: TILED FLOORS SHALL BE SIMILAR AS GENERAL, EXCEPT WITH SQUARE TOP. <br />E. CLEANOUTS IN WATERPROOF MEMBRANE FLOORS SHALL HAVE A FLASHING FLANGE WITH FLASHING CLAMP. <br />F. CLEANOUTS IN BATTERY ROOMS SHALL HAVE AN ACID RESISTANT EPDXY COATED BODY AND COVER. <br />G. ACCEPTABLE MANUFACTURERS: <br />1. JAY R. SMITH MFG. CO. <br />2. JOSAM COMPANY. <br />3. WADE. <br />4. ZURN. <br />2.05 SLEEVES <br />A. GENERAL: PIPES PASSING THROUGH FOUNDATION WALLS OR FLOORS SHALL BE SLEEVED MEETING <br />REQUIREMENTS OF SECTION 07835 - SLEEVES AND SEALS. <br />PART 3 - EXECUTION <br />3.01 EXAMINATION <br />A. GENERAL: EXAMINE AREAS AND CONDITIONS UNDER WHICH WORK IS TO BE INSTALLED FOR COMPLIANCE WITF• <br />REQUIREMENTS OF CONTRACT DOCUMENTS AND TO DETERMINE IF CONDITIONS AFFECTING PERFORMANCE 01 <br />WORK ARE SATISFACTORY. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE <br />BEEN RESOLVED. COMMENCEMENT OF INSTALLATION SHALL CONSTITUTE ACCEPTANCE OF CONDITIONS. <br />3.02 PROTECTION <br />A. PROTECT UNDERGROUND PLUMBING WORK TO AVOID CLOGGING WITH MATERIALS AND DEBRIS AND TO PREVE <br />DAMAGE FROM TRAFFIC AND OTHER WORK. <br />MEP / FP Engineer <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Design Architect <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />3.03 INSTALLATION <br />A. GENERAL: INSTALL WORK MEETING REQUIREMENTS OF CONTRACT DOCUMENTS, AS INDICATED BY FINAL <br />REVIEWED SUBMITTALS FOR WORK, AND MEETING INSTRUCTIONS AND RECOMMENDATIONS OF PRODUCT <br />MANUFACTURERS. <br />B. RUNS: LOCATE PIPING RUNS, EXCEPT AS OTHERWISE REQUIRED, VERTICALLY AND HORIZONTALLY PITCHED TO <br />DRAIN AND AVOID DIAGONAL RUNS WHEREVER POSSIBLE. ORIENT HORIZONTAL RUNS PARALLEL WITH WALLS <br />AND COLUMN LINES. LOCATE RUNS AS INDICATED ON DRAWINGS, DIAGRAMS, DETAILS AND NOTATIONS OR, IF <br />NOT OTHERWISE INDICATED, RUN PIPING IN SHORTEST ROUTE WITH A MINIMUM OF JOINTS AND COUPLINGS. <br />C. PIPING SYSTEM JOINTS: PROVIDE JOINT TYPE REQUIRED FOR EACH PIPING SYSTEM. <br />1. INSTALL PIPE, TUBE AND FITTINGS IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES WHICH ACHIEVE <br />PERMANENT LEAK PROOF PIPING SYSTEMS, CAPABLE OF PERFORMING WITHOUT PIPING FAILURE. <br />2. COPPER TUBE: SOLDER COPPER TUBE AND FITTING JOINTS. CUT TUBE ENDS SQUARELY, REAM TO FULL <br />INSIDE DIAMETER, AND CLEAN OUTSIDE OF TUBE ENDS AND INSIDE OF FITTINGS. APPLY SOLDER FLUX TO <br />JOINT AREAS OF BOTH TUBES AND FITTINGS. INSERT TUBE FULL DEPTH INTO FITTING, AND SOLDER IN A <br />MANNER TO DRAW SOLDER FULL DEPTH AND CIRCUMFERENCE OF JOINT. WIPE EXCESS SOLDER FROM JOINT <br />BEFORE IT HARDENS. <br />3. EXCAVATION AND BACKFILL: <br />a. EXCAVATION: WHERE TRENCHES ARE EXCAVATED SUCH THAT THE BOTTOM OF THE TRENCH FORMS THE <br />BED FOR THE PIPE, SOLID AND CONTINUOUS LOAD -BEARING SUPPORT SHALL BE PROVIDED BETWEEN <br />JOINTS. PIPES SHALL NOT BE SUPPORTED ON BLOCKS TO GRADE. IN INSTANCES WHERE THE MATERIALS <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE MORE RESTRICTIVE THAN THOSE PRESCRIBED BY <br />CODE, THE MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THE MORE RESTRICTIVE REQUIREMENT. <br />1) OVEREXCAVATION: WHERE TRENCHES ARE EXCAVATED BELOW THE INSTALLATION LEVEL OF THE PIPE <br />SUCH THAT THE BOTTOM OF THE TRENCH DOES NOT FORM THE BED FOT THE PIPE, THE TRENCH SHALL BE <br />BACKFILLED TO THE INSTALLATION LEVEL OF THE BOTTOM OF THE PIPE WITH SAND OR FINE GRAVEL <br />PLACED IN LAYERS OF 6 INCHES MAXIMUM DEPTH AND SUCH BACKFILL SHALL BE COMPACTED AFTER EACH <br />PLACEMENT. <br />b. BACKFILLING: BACKFILL SHALL BE FREE FROM DISCARDED CONSTRUCTION MATERIAL AND DEBRIS. LOOSE <br />EARTH FREE FROM ROCKS, BROKEN CONCRETE, AND FROZEN CHUNKS SHALL BE PLACED IN THE TRENCH IN <br />6 INCH LAYERS AND TAMPED IN PLACE UNTIL THE CROWN OF THE PIPE IS COVERED BY 12 INCHES OF <br />TAMPED EARTH. THE BACKFILL UNDER AND BESIDE THE PIPE SHALL BE COMPACTED FOR PIPE SUPPORT. <br />BACKFILL SHALL BE BROUGHT UP EVENLY ON BOTH SIDES OF THE PIPE SO THAT THE PIPE REMAINS <br />ALIGNED. IN INSTANCES WHERE THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE MATERIALS <br />ARE MORE RESTRICTIVE THAN THOSE PRESCRIBED BY THE CODE, THE MATERIAL SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE MORE RESTRICTIVE REQUIREMENT. <br />3.04 PIPING TESTS <br />A. PROVIDE TEMPORARY EQUIPMENT FOR TESTING, INCLUDING PUMP AND GAUGES. TEST PIPING SYSTEM BEFORE <br />BACKFILLING IS INSTALLED WHEREVER FEASIBLE. TEST EACH NATURAL SECTION OF EACH PIPING SYSTEM <br />INDEPENDENTLY. FILL EACH SECTION WITH WATER AND PRESSURIZE FOR INDICATED PRESSURE AND TIME. <br />B. INSPECT EACH SYSTEM FOR COMPLETION OF JOINTS, SUPPORTS AND ACCESSORY ITEMS <br />C. OBSERVE EACH TEST SECTION FOR LEAKAGE AT END OF TEST PERIOD. TEST FAILS IF LEAKAGE IS OBSERVED OR <br />IF PRESSURE DROP EXCEEDS 5 PERCENT OF TEST PRESSURE. <br />D. REPAIRING: REPAIR PIPING SYSTEMS SECTIONS WHICH FAIL THE PIPING PRESSURE TEST, BY DISASSEMBLY AND <br />REINSTALLATION, USING NEW MATERIAL TO EXTENT REQUIRED TO OVERCOME LEAKAGE. DO NOT USE <br />CHEMICALS, STOP LEAK COMPOUNDS, MASTIC, OR OTHER TEMPORARY REPAIR METHODS. DRAIN TEST WATER <br />FROM PIPING SYSTEMS AFTER TESTING AND REPAIR WORK HAS BEEN COMPLETED. <br />3.05 CLEANING <br />A. FLUSH OUT PIPING SYSTEMS WITH CLEAN WATER BEFORE PROCEEDING WITH REQUIRED DISINFECTION TESTS. <br />END OF SECTION <br />Nestle Waters North America <br />Nestle Waters North America <br />4330 20th Street <br />Zephyrhills, Florida 33542-6703 <br />972.462.3663 <br />:retleers <br />NORTH AMERICA <br />4 <br />09.18.2013 <br />ISSUE FOR PERMIT <br />3 <br />09.11.2013 <br />ISSUE FOR BIDS <br />2 <br />09.03.2013 <br />CD REVIEW PACKAGE <br />1 <br />08.16.2013 <br />DD REVIEW PACKAGE <br />NO. <br />DATE <br />REVISIONS/ISSUANCES <br />PSTEIN <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: <br />12386 <br />PROJECT MANAGER: <br />JK <br />ARCH/ENG: <br />VD <br />SCALE: <br />NTS <br />DRAWN BY: <br />PV <br />CHECKED BY: <br />VD <br />PLUMBING <br />SPECIFICATIONS <br />P-003 <br />2 LY •/ If, <br />A. Epstein and Sons International, Ina All rights reserved. <br />