Laserfiche WebLink
SECTION 061000 - ROUGH CARPENTRY <br />1.01 SECTION INCLUDES <br />A. TELEPHONE AND ELECTRICAL PANEL BOARDS. <br />B. WOOD NAILERS AND CURBS FOR ROOFING AND ITEMS INSTALLED ON <br />ROOF. <br />C. CONCEALED WOOD BLOCKING FOR SUPPORT OF EQUIPMENT, SOFFIT <br />PANELS, AND SIGNAGE. <br />D. MISCELLANEOUS WOOD NAILERS AND FURRING STRIPS. <br />1.02 REFERENCES <br />A. AFPA T10 - WOOD FRAME CONSTRUCTION MANUAL, AMERICAN <br />FOREST AND PAPER ASSOCIATION, 2001. <br />B. AWPA C2 - LUMBER, TIMBER, BRIDGE TIES AND MINE TIES - <br />PRESERVATIVE TREATMENT BY PRESSURE PROCESSES, AMERICAN <br />WOOD -PRESERVERS' ASSOCIATION, 2001. <br />C. PS - AND INDUSTRIAL PLYWOOD NATIONAL <br />1 CONSTRUCTION N , <br />INSTITUTE OF STANDARDS AND TECHNOLOGY (DEPARTMENT OF <br />COMMERCE), 1995. D. PS 20 - AMERICAN SOFTWOOD LUMBER <br />STANDARD, NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY <br />(DEPARTMENT OF COMMERCE), 1999. E. WWPA G-5 - WESTERN <br />LUMBER GRADING RULES, WESTERN WOOD PRODUCTS ASSOCIATION, <br />1998. <br />1.03 QUALITY ASSURANCE <br />A. LUMBER: COMPLY WITH PS 20 AND APPROVED GRADING RULES AND <br />INSPECTION AGENCIES. <br />1.04 DELIVERY, STORAGE, AND HANDLING <br />A. COVER WOOD PRODUCTS TO PROTECT AGAINST MOISTURE. <br />SUPPORT STACKED PRODUCTS TO PREVENT DEFORMATION AND TO <br />ALLOW AIR CIRCULATION. <br />PART 2 -PRODUCTS <br />2.01 DIMENSION LUMBER FOR CONCEALED APPLICATIONS - ALL SHALL BE FIRE <br />RETARDANT TREATED <br />A. GRADING AGENCY: WESTERN WOOD PRODUCTS ASSOCIATION <br />(VW11PA). <br />B. SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S. <br />C. MOISTURE CONTENT: S-DRY OR MC19. <br />D. MISCELLANEOUS BLOCKING, FURRING, AND NAILERS: <br />1. LUMBER: S4S, NO.2 OR STANDARD GRADE. <br />2.02 CONSTRUCTION PANELS -ALL SHALL BE FIRE RETARDANT TREATED <br />A. MISCELLANEOUS PANELS: <br />1. CONCEALED PLYWOOD: PS 1, C-C PLUGGED, EXTERIOR <br />GRADE. <br />2. EXPOSED PLYWOOD: PS 1, A-D, INTERIOR GRADE. <br />3. ELECTRICAL COMPONENT MOUNTING: APA RATED SHEATHING, <br />FIRE RETARDANT TREATED. <br />2.03 ACCESSORIES <br />A. FASTENERS AND ANCHORS: <br />1. FASTENERS: ZINC ELECTROPLATED STEEL FOR HIGH <br />HUMIDITY AND TREATED WOOD LOCATIONS, UNFINISHED <br />STEEL ELSEWHERE. <br />2. DRYWALL SCREWS: BUGLE HEAD, HARDENED STEEL, POWER <br />DRIVEN TYPE, LENGTH THREE TIMES THICKNESS OF <br />SHEATHING. <br />3. ANCHORS: TOGGLE BOLT TYPE FOR ANCHORAGE TO HOLLOW <br />MASONRY, EXPANSION SHIELD AND LAG BOLT AT SOLID <br />MASONRY, BOLT ADN BALLISTIC ANCHORAGES TO STEEL. <br />2.04 FACTORY WOOD TREATMENT <br />A. TREATED LUMBER AND PLYWOOD: COMPLY WITH REQUIREMENTS OF <br />AWPA U1-05 - USE CATEGORY SYSTEM FOR WOOD TREATMENTS <br />DETERMINED BY USE CATEGORIES, EXPECTED SERVICE CONDITIONS, <br />AND SPECIFIC APPLICATIONS. <br />B. FIRE -RETARDANT -TREATED MATERIALS <br />1. GENERAL: COMPLY WITH PERFORMANCE REQUIREMENTS IN <br />AWPA C20 (LUMBER) AND AWPA C27 (PLYWOOD). FLAME <br />SPREAD SHALL BE 25 OR LESS PER ASTM E84 <br />a. USE EXTERIOR TYPE FOR EXTERIOR LOCATIONS AND WHERE INDICATED. <br />b. USE INTERIOR TYPE A, HIGH TEMPERATURE (HT) FOR ENCLOSED ROOF <br />FRAMING, FRAMING IN ATTIC SPACES, AND WHERE INDICATED. <br />C. USE INTERIOR TYPE A, UNLESS OTHERWISE INDICATED. <br />2. IDENTIFY FIRE -RETARDANT -TREATED WOOD WITH <br />APPROPRIATE CLASSIFICATION MARKING OF TESTING AND <br />INSPECTING AGENCY; AND WITH INFORMATION ACCEPTABLE <br />TO AUTHORITIES HAVING JURISDICTION. <br />C. SURFACE MOUNTED AND WALL BLOCKING <br />1. FIRE -RETARDANT -TREATED MATERIALS <br />a. GENERAL: COMPLY WITH PERFORMANCE REQUIREMENTS IN AWPA C20 <br />(LUMBER) AND AWPA C27 (PLYWOOD). FLAME SPREAD SHALL BE 25 OR LESS PER <br />ASTM E84. <br />b. USE EXTERIOR TYPE FOR EXTERIOR LOCATIONS AND <br />WHERE INDICATED. <br />C. USE INTERIOR TYPE A, HIGH TEMPERATURE (HT) FOR ENCLOSED <br />ROOF FRAMING, FRAMING IN ATTIC SPACES, AND WHERE <br />INDICATED. <br />d. USE INTERIOR TYPE A, UNLESS OTHERWISE INDICATED. <br />D. IDENTIFY FIRE -RETARDANT -TREATED WOOD WITH APPROPRIATE <br />CLASSIFICATION MARKING OF TESTING AND INSPECTING AGENCY; <br />AND WITH INFORMATION ACCEPTABLE TO AUTHORITIES HAVING <br />JURISDICTION. <br />E. PLYWOOD BACKING PANELS <br />1. TELEPHONE, ELECTRICAL, EQUIPMENT BACKING PANELS: DOC <br />PS 1, EXPOSURE 1, C-D PLUGGED, FIRE -RETARDANT TREATED, <br />IN THICKNESS INDICATED OR, IF NOT INDICATED, NOT LESS <br />THAN 3/44NCH (19-MM) NOMINAL THICKNESS. 4'x8' BOARD. <br />2. WATER DELIVERY SYSTEM, FIRE-RETARDENT TREATED IN <br />THICKNESS INDICATED OR, IF NOT INDICATED, NOT LESS THAN <br />5/8-INCH (1 3-MM) NOMINAL THICKNESS. <br />F. PRESSURE TREATMENT OF LUMBER ABOVE GRADE: AWPA <br />TREATMENT C2 USING WATERBORNE PRESERVATIVE TO 0.25 LB/CU FT <br />(4.0 KG/CU M) RETENTION. <br />1. KILN DRY AFTER TREATMENT TO MAXIMUM MOISTURE <br />CONTENT OF 19 PERCENT. <br />2. TREAT WOOD IN CONTACT WITH ROOFING, FLASHING, OR <br />WATERPROOFING. <br />3. TREAT WOOD IN CONTACT WITH MASONRY OR CONCRETE. <br />4. TREAT WOOD LESS THAN 18 INCHES (450 MM) ABOVE GRADE. <br />PART 3 - EXECUTION <br />3.01 FURRING INSTALLATION <br />A. SET FURRING, NAILERS AND BLOCKING MEMBERS LEVEL, PLUMB, AND <br />TRUE TO LINE. DISCARD PIECES WITH DEFECTS THAT WOULD LOWER <br />REQUIRED STRENGTH. <br />B. MAKE PROVISIONS FOR TEMPORARY CONSTRUCTION LOADS, AND <br />PROVIDE TEMPORARY BRACING SUFFICIENT TO MAINTAIN <br />STRUCTURE IN TRUE ALIGNMENT AND SAFE CONDITION UNTIL <br />COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT <br />BRACING. <br />C. INSTALL MEMBERS FULL LENGTH WITHOUT SPLICES UNLESS <br />OTHERWISE SPECIFICALLY DETAILED. <br />D. COMPLY WITH MEMBER SIZES, SPACING, AND CONFIGURATIONS <br />INDICATED, AND FASTENER SIZE AND SPACING INDICATED, BUT NOT <br />LESS THAN REQUIRED BY AFPA WOOD FRAME CONSTRUCTION <br />MANUAL. E. PROVIDE MISCELLANEOUS MEMBERS AS INDICATED OR <br />AS REQUIRED TO SUPPORT FINISHES, FIXTURES, SPECIALTY ITEMS, <br />AND TRIM. <br />3.02 SITE APPLIED WOOD TREATMENT <br />A. APPLY PRESERVATIVE TREATMENT COMPATIBLE WITH FACTORY <br />APPLIED TREATMENT AT SITE -SAWN CUTS, COMPLYING WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />B. ALLOW PRESERVATIVE TO DRY PRIOR TO ERECTING MEMBERS. <br />END OF SECTION <br />SECTION 062000 - FINISH CARPENTRY <br />PART1 GENERAL <br />1.01 SECTION INCLUDES <br />A. <br />INSTALLATION OF MILLWORK. <br />B. <br />INSTALLATION OF OWNER RETAIL SHELVING (COORDINATE WITH PET <br />SUPPLIES PLUS).. <br />C. <br />FINISH CARPENTRY ITEMS. <br />D. <br />HARDWARE AND ATTACHMENT ACCESSORIES. <br />1.02 REFERENCES <br />A. <br />AWI (QSI) - ARCHITECTURAL WOODWORK QUALITY STANDARDS <br />ILLUSTRATED, ARCHITECTURAL WOODWORK INSTITUTE, 1997, <br />SEVENTH EDITION, VERSION 1.0. <br />B. <br />BHMA A156.9 - AMERICAN NATIONAL STANDARD FOR CABINET <br />HARDWARE, BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, <br />2003 (ANSI/BHMA Al56.9). <br />C. <br />NEMA LD 3 - HIGH-PRESSURE DECORATIVE LAMINATES, NATIONAL <br />ELECTRICAL MANUFACTURERS ASSOCIATION, 2000. <br />1.03 SUBMITTALS <br />A. <br />SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS FOR <br />SUBMITTAL PROCEDURES. <br />B. <br />SHOP DRAWINGS: INDICATE MATERIALS, COMPONENT PROFILES, <br />FASTENING METHODS, JOINTING DETAILS, AND ACCESSORIES TO A <br />MINIMUM SCALE OF 1-1/2 INCH TO 1 FT (1:8). <br />C. <br />SAMPLES: SUBMIT TWO SAMPLES OF WOOD TRIM 6 INCHES LONG. <br />1.04 QUALITY ASSURANCE <br />1.05 DELIVERY, STORAGE, AND PROTECTION <br />A. <br />PROTECT WORK FROM MOISTURE DAMAGE. <br />1.06 PROJECT CONDITIONS <br />A. <br />SEQUENCE INSTALLATION TO ENSURE UTILITY CONNECTIONS ARE <br />ACHIEVED IN AN ORDERLY AND EXPEDITIOUS MANNER. <br />B. <br />COORDINATE THE WORK WITH PLUMBING ROUGH -IN, ELECTRICAL <br />ROUGH -IN, AND INSTALLATION OF ASSOCIATED AND ADJACENT <br />COMPONENTS. <br />PART 2 PRODUCTS <br />2.01 PLASTIC LAMINATE MATERIALS <br />A. <br />PLASTIC LAMINATE: NEMA LD 3, HGS, VGS, HGP AS REQUIRED TO SUIT <br />APPLICATION, COLOR AND TEXTURE AS INDICATED ON DRAWINGS. <br />B. <br />LOW PRESSURE LAMINATE: MELAMINE, COLOR AS SPECIFIED ON <br />DRAWINGS, AND SURFACE TEXTURE AS SELECTED. <br />C. <br />LAMINATE BACKING SHEET: NEMA LD 3, BKL, UNDECORATED PLASTIC <br />LAMINATE. <br />D. <br />ADHESIVE: OF TYPES BEST SUITED TO INSTALLATION. <br />2.02 WOOD TRIM <br />A. <br />SOFTWOOD LUMBER: GRADED IN ACCORDANCE WITH AWI <br />ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED, <br />CUSTOM, AVERAGE MOISTURE CONTENT OF 6 PERCENT, SPECIES <br />AND GRADE AS FOLLOWSINDICATED ON DRAWINGS. <br />B. <br />HARDWOOD LUMBER: GRADED IN ACCORDANCE WITH AWI <br />ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED, <br />CUSTOM, AVERAGE MOISTURE CONTENT OF 6 PERCENT, SPECIES <br />AND GRADE AS FOLLOWS: CLEAR POPLAR. <br />2.03 FASTENERS <br />A. <br />FASTENERS: OF SIZE AND TYPE TO SUIT APPLICATION. <br />B. <br />CONCEALED JOINT FASTENERS: THREADED STEEL. <br />2.04 ACCESSORIES <br />A. <br />LUMBER FOR SHIMMING, BLOCKING: SOFTWOOD LUMBER OF CEDAR <br />SPECIES. <br />B. <br />PRIMER: ALKYD PRIMER SEALER TYPE. <br />C. <br />WOOD FILLER: SOLVENT BASE, TINTED TO MATCH SURFACE FINISH <br />COLOR. <br />2.05 HARDWARE <br />A. <br />HARDWARE: COMPLY WITH BHMA A156.9 AND AS INDICATED ON <br />DRAWINGS. <br />2.06 FABRICATION <br />A. <br />SHOP ASSEMBLE WORK FOR DELIVERY TO SITE, PERMITTING <br />PASSAGE THROUGH BUILDING OPENINGS. <br />B. <br />CAP EXPOSED PLASTIC LAMINATE FINISH EDGES WITH MATERIAL OF <br />SAME FINISH AND PATTERN. <br />C. <br />WHEN NECESSARY TO CUT AND FIT ON SITE, PROVIDE MATERIALS <br />WITH AMPLE ALLOWANCE FOR CUTTING. PROVIDE TRIM FOR <br />SCRIBING AND SITE CUTTING. <br />D. <br />APPLY PLASTIC LAMINATE FINISH IN FULL UNINTERRUPTED SHEETS <br />CONSISTENT WITH MANUFACTURED SIZES. FIT CORNERS AND JOINTS <br />HAIRLINE, SECURE WITH CONCEALED FASTENERS. SLIGHTLY BEVEL <br />ARISES. LOCATE COUNTER BUTT JOINTS MINIMUM 2 FEET (600 MM) <br />FROM SINK CUT-OUTS. <br />E. <br />APPLY LAMINATE BACKING SHEET TO REVERSE FACE OF PLASTIC <br />LAMINATE FINISHED SURFACES. <br />F. <br />SHOP ASSEMBLE CASEWORK FOR DELIVERY TO SITE IN UNITS EASILY <br />HANDLED AND TO PERMIT PASSAGE THROUGH BUILDING OPENINGS. <br />G. <br />FIT SHELVES, DOORS, AND EXPOSED EDGES WITH MATCHING VENEER <br />EDGING OR AS DETAILED ON DRAWINGS. USE ONE PIECE FOR FULL <br />LENGTH ONLY. <br />H. <br />DOOR AND DRAWER FRONTS: 3/4 INCH (19 MM) THICK, FLUSH <br />OVERLAY STYLE. <br />I. <br />WHEN NECESSARY TO CUT AND FIT ON SITE, PROVIDE MATERIALS <br />WITH AMPLE ALLOWANCE FOR CUTTING. PROVIDE TRIM FOR <br />SCRIBING AND SITE CUTTING. <br />J. <br />APPLY PLASTIC LAMINATE FINISH IN FULL UNINTERRUPTED SHEETS <br />CONSISTENT WITH MANUFACTURED SIZES. FIT CORNERS AND JOINTS <br />HAIRLINE, SECURE WITH CONCEALED FASTENERS. SLIGHTLY BEVEL <br />ARISES. LOCATE COUNTER BUTT JOINTS MINIMUM 2 FEET (600 MM) <br />FROM SINK CUT-OUTS. <br />K. <br />APPLY LAMINATE BACKING SHEET TO REVERSE SIDE OF PLASTIC <br />LAMINATE FINISHED SURFACES. <br />L. <br />FABRICATE METAL COUNTERTOP SURFACES PRESSURE GLUED TO <br />PARTICLE BOARD CORE BACKING WITHOUT VISIBLE JOINTS. <br />M. <br />MECHANICALLY FASTEN BACK SPLASH TO COUNTERTOPS WITH STEEL <br />BRACKETS AT 16 INCHES (400 MM) ON CENTER. <br />2.07 SHOP FINISHING <br />A. <br />SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS. <br />B. <br />APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS. <br />C. <br />ON ITEMS TO RECEIVE TRANSPARENT FINISHES, USE WOOD FILLER <br />WHICH MATCHES SURROUNDING SURFACES AND OF TYPES <br />RECOMMENDED FOR APPLIED FINISHES. <br />D. <br />FINISH WORK IN ACCORDANCE WITH AWI ARCHITECTURAL <br />WOODWORK QUALITY STANDARDS ILLUSTRATED, SECTION 1500, <br />SYSTEM TR-2 (TRANSPARENT). <br />E. <br />BACK PRIME WOODWORK ITEMS TO BE FIELD FINISHED, PRIOR TO <br />INSTALLATION. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />VERIFY ADEQUACY OF BACKING AND SUPPORT FRAMING. <br />B. <br />VERIFY MECHANICAL, ELECTRICAL, AND BUILDING ITEMS AFFECTING <br />WORK OF THIS SECTION ARE PLACED AND READY TO RECEIVE THIS <br />WORK. <br />C. <br />SEE SECTION 061000-ROUGH CARPENTRY FOR INSTALLATION OF <br />RECESSED AND CONCEALED WOOD BLOCKING. <br />3.02 INSTALLATION <br />A. <br />SET AND SECURE MATERIALS AND COMPONENTS IN PLACE, PLUMB <br />AND LEVEL. <br />B. <br />CAREFULLY SCRIBE WORK ABUTTING OTHER COMPONENTS, WITH <br />MAXIMUM GAPS OF 1/32 INCH (1 MM). DO NOT USE ADDITIONAL <br />OVERLAY TRIM TO CONCEAL LARGER GAPS. <br />C. <br />INSTALL COMPONENTS, FIXTURES AND TRIM WITH FASTENERS AND <br />ADHESIVES AS INDICATED ON FABRICATORS SHOP DRAWINGS. <br />PROVIDE MECHANICAL FASTENERS FOR THE INSTALLATION OF ALL <br />COMPONENTS, INCLUDING INSTALLATIONS USING ADHESIVES. <br />D. <br />INSTALL HARDWARE. <br />3.03 PREPARATION FOR SITE FINISHING <br />A. <br />SET EXPOSED FASTENERS. APPLY WOOD FILLER IN EXPOSED <br />FASTENER INDENTATIONS. SAND WORK SMOOTH. <br />B. <br />SITE FINISHING: REFER TO SECTION 099100. <br />C. <br />BEFORE INSTALLATION, PRIME PAINT SURFACES OF ITEMS OR <br />ASSEMBLIES TO BE IN CONTACT WITH CEMENTITIOUS MATERIALS. <br />3.04 ERECTION TOLERANCES <br />A. <br />MAXIMUM VARIATION FROM TRUE POSITION: 1/16 INCH (1.5 MM). <br />B. <br />MAXIMUM OFFSET FROM TRUE ALIGNMENT WITH ABUTTING <br />MATERIALS: 1/32 INCH (0.7 MM). <br />3.05 SCHEDULE <br />A. <br />INSTALLATION SCHEDULE IS INDICATED ON DRAWINGS. <br />END OF SECTION <br />SECTION 072100 - THERMAL INSULATION <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. BOARD INSULATION AT EXTERIOR WALL BEHIND INTERIOR GYPSUM <br />BOARD WALL FINISH. <br />B. BATT INSULATION AND VAPOR RETARDER IN EXTERIOR WALL <br />CONSTRUCTION AND INTERIOR WALLS. <br />C. BATT INSULATION FOR FILLING CREVICES IN EXTERIOR WALL AND <br />ROOF. <br />D. SOUND INSULATION FOR DEMISING WALLS AT PUBLIC PET WASH OR <br />GROOMING AREAS. <br />1.02 REFERENCES <br />A. ASTM C 578 - STANDARD SPECIFICATION FOR RIGID, CELLULAR <br />POLYSTYRENE THERMAL INSULATION, 2001. <br />B. ASTM C 665 - STANDARD SPECIFICATION FOR MINERAL -FIBER <br />BLANKET THERMAL INSULATION FOR LIGHT FRAME CONSTRUCTION <br />AND MANUFACTURED HOUSING, 2001. <br />1.03 ENVIRONMENTAL REQUIREMENTS <br />A. DO NOT INSTALL INSULATION ADHESIVES WHEN TEMPERATURE OR <br />WEATHER CONDITIONS ARE DETRIMENTAL TO SUCCESSFUL <br />INSTALLATION. <br />PART 2 PRODUCTS <br />2.01 BOARD INSULATION MATERIALS <br />A. EXTRUDED POLYSTYRENE BOARD INSULATION: ASTM C 578, TYPE IV, <br />EXTRUDED POLYSTYRENE BOARD WITH EITHER NATURAL SKIN OR <br />CUT CELL SURFACES, WITH THE FOLLOWING CHARACTERISTICS: <br />1. BOARD SIZE: 24 X 96 INCH (1220 X 2440 MM). <br />2. BOARD THICKNESS: THICKNESS IN INCHES( MM) AS <br />INDICATED ON DRAWINGS.. <br />3. BOARD EDGES: SQUARE. <br />4. COMPRESSIVE RESISTANCE: 15 PSI (173 KPA). <br />5. BOARD DENSITY: 1.3 LB/CU FT (21 KG/CU M). <br />6. MANUFACTURERS: <br />a. DOW CHEMICAL CO: WWW.DOW.COM, STYROFOAM Z-MATE. <br />b. OWENS CORNING CORP: WWW.OWENSCORNING.COM. <br />C. PACTIV BUILDING PRODUCTS: WWW.PACTIVBUILDINGPRODUCTS.COM. <br />7. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />2.02 BATT INSULATION MATERIALS <br />A. BATT INSULATION: ASTM C 665, PREFORMED GLASS FIBER BATT FOR <br />THERMAL AND SOUND ATTENUATION APPLICATIONS, FRICTION FIT, <br />CONFORMING TO THE FOLLOWING: <br />1. THICKNESS: AS INDICATED. <br />2. MANUFACTURERS: <br />a. CERTAINTEED CORPORATION: WWW.CERTAINTEED.COM. <br />b. JOHNS MANVILLE CORPORATION: WWW.JM.COM. <br />C. OWENS CORNING CORP: WWW.OWENSCORNING.COM. <br />3. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />2.03 SOUND ATTENUATION BATTS <br />A. TYPE: UNFACED GLASS FIBER ACOUSTICAL INSULATION COMPLYING <br />WITH ASTM C665, TYPE 1. <br />B. SIZE: <br />THICKNESS WIDTH LENGTH <br />3-112' 89MM 16" 406MM 24" 609MM 96" 2438MM <br />2-112" 64MM 16" 406MM 24" 609MM 96" 2438MM <br />C. SIZE:SURFACE BURNING CHARACTERISTICS: <br />1. MAXIMUM FLAME SPREAD. 10 <br />2. MAXIMUM SMOKE DEVELOPED: 10 <br />WHEN TESTED IN ACCORDANCE WITH ASTM E 84. <br />D. COMBUSTION CHARACTERISTICS: PASSES ASTM E 136. <br />E. FIRE RESISTANCE RATINGS: PASSES ASTM E 119 AS PART OF A <br />COMPLETE FIRE TESTED WALL ASSEMBLY. <br />F. SOUND TRANSMISSION CLASS: STC50 <br />G. DIMENSIONAL STABILITY: LINEAR SHRINKAGE LESS THAN 0.1 % <br />H. MANUFACTURERS: <br />a. DOW CHEMICAL CO: WWW.DOW.COM, STYROFOAM Z-MATE. <br />b. OWENS CORNING CORP: WWW.OWENSCORNING.COM. <br />C. PACTIV BUILDING PRODUCTS: WWW.PACTIVBUILDINGPRODUCTS.COM. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. VERIFY THAT SUBSTRATE, ADJACENT MATERIALS, AND INSULATION <br />MATERIALS ARE DRY AND THAT SUBSTRATES ARE READY TO RECEIVE <br />INSULATION. <br />B. VERIFY SUBSTRATE SURFACES ARE FLAT, FREE OF IRREGULARITIES. <br />3.02 BOARD INSTALLATION AT EXTERIOR WALLS <br />A. APPLY ADHESIVE TO BACK OF BOARDS: <br />B. INSTALL BOARDS VERTICALLY ON WALLS. <br />END OF SECTION <br />SECTION 077100 - ROOFING <br />PART 1 GENERAL <br />1.01 ROOF IS EXISTING. ALL WORK SHALL BE IN CONFORMANCE WITH THE <br />LANDLORD ROOF SYSTEM MANUFACTURER'S SPECIFICATIONS REQUIRED <br />TO MAINTAIN WARRANTY. <br />1.02 ALL ROOF WORK TO BE PERFORMED BY LANDLORD ROOFING <br />CONTRACTOR. <br />PART 2 PRODUCTS <br />2.01 PROVIDE ALL INSULATION, ROOF MEMBRANE, FLASHING, ADHEASIVES AND <br />FASTENERS REQUIRED TO PROVIDE A COMPLETE INSTALLATION. <br />2.2. PROVIDE BUILT-UP CRICKETS AND SADDLES TO PROVIDE POSITIVE <br />DRAINAGE AROUND ROOF MOUNTED EQUIPMENT. <br />PART 3 EXECUTION <br />3.01 PROTECT EXISTING ROOF SYSTEM FROM DAMAGE DURING CONSTRUCTION. <br />3.02 INSTALL WORK IN ACCORDANCE WITH MANUFACTURER'S WRITTEN <br />INSTRUCTIONS AND DETAILS. <br />3.03 INSTALL INSULATION IN FULL THICKNESS AT ALL ROOF OPENINGS. <br />END OF SECTION <br />SECTION 079200 - JOINT SEALANTS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. SEALANTS AND JOINT BACKING. <br />B. PRECOMPRESSED FOAM SEALERS. <br />1.02 REFERENCES <br />A. ASTM C 920 - STANDARD SPECIFICATION FOR ELASTOMERIC JOINT <br />SEALANTS, 2002. <br />B. ASTM C 1193 - STANDARD GUIDE FOR USE OF JOINT SEALANTS, 2000. <br />C. ASTM D 1056 - STANDARD SPECIFICATION FOR FLEXIBLE CELLULAR <br />MATERIALS -SPONGE OR EXPANDED RUBBER, 2000. <br />D. ASTM D 1667 - STANDARD SPECIFICATION FOR FLEXIBLE CELLULAR <br />MATERIALS -VINYL CHLORIDE POLYMERS AND COPOLYMERS <br />(CLOSED -CELL FOAM), 1997. <br />E. ASTM D 2628 - STANDARD SPECIFICATION FOR PREFORMED <br />POLYCHLOROPRENE ELASTOMERIC JOINT SEALS FOR CONCRETE <br />PAVEMENTS, 1991 (REAPPROVED 1998). <br />1.03 SUBMITTALS <br />A. SEE SECTION 013000 -ADMINISTRATIVE REQUIREMENTS, FOR <br />SUBMITTAL PROCEDURES. <br />B. PRODUCT DATA: PROVIDE DATA INDICATING SEALANT CHEMICAL <br />CHARACTERISTICS. <br />C. MANUFACTURERS COLOR SELECTION CHART FOR COLOR <br />VERIFICATION AT EXPOSED TO VIEW SEALANTS. <br />1.04 QUALITY ASSURANCE <br />A. MAINTAIN ONE COPY OF EACH REFERENCED DOCUMENT COVERING <br />INSTALLATION REQUIREMENTS ON SITE. <br />B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN <br />PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 3 YEARS <br />EXPERIENCE. <br />1.05 ENVIRONMENTAL REQUIREMENTS <br />A. MAINTAIN TEMPERATURE AND HUMIDITY RECOMMENDED BY THE <br />SEALANT MANUFACTURER DURING AND AFTER INSTALLATION. <br />1.06 WARRANTY <br />A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL <br />WARRANTY REQUIREMENTS. <br />B. CORRECT DEFECTIVE WORK WITHIN A FIVE YEAR PERIOD AFTER DATE <br />OF SUBSTANTIAL COMPLETION. <br />C. WARRANTY: INCLUDE COVERAGE FOR INSTALLED SEALANTS AND <br />ACCESSORIES WHICH FAIL TO ACHIEVE AIRTIGHT SEAL <br />D. GENERAL WARANTY: SPECIAL WARRANTIES SPECIFIED IN THIS <br />ARTICLE SAHLL NOT DEPRIEVE THE OWNER OF OTHER RIGHTS THE <br />OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT <br />DOCUMENTS AND SHALL BE IN ADDITON TO AND RUM CONCURRENT <br />WITH THE OTHER WARRANTIES MADE BY THE CONTRACTOR UNDER <br />REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />E. SPECIAL INSTALLERS WARRANTY: WRITTEN WARRANTY SIRNED BY <br />THE INSTALLER AGEEING TO REPAIR OR REPLACE ELATOMERIC JOINT <br />SEALANTS THAT DO NOT COMPLY WITHTHE PERFORMANCE AND <br />OTHER REQUIREMENTS OF THIS SECTION WITHIN A WARRANTY <br />PERIOD OF TWO YEARS FOR THE DATE OF SUBSTANTIAL <br />COMPLETION. <br />F. SPECIAL MANUFACTURERS WARRANTY: WRITTEN WARRANTY SIGNED <br />BY THE MANUFACTURER AGEEING TO REPAIR OR REPLACE <br />ELATOMERIC JOINT SEALANTS THAT DO NOT COMPLY WITHTHE <br />PERFORMANCE AND OTHER REQUIREMENTS OF THIS SECTION WITHIN <br />A WARRANTY PERIOD OF FIVE YEARS FOR THE DATE OF SUBSTANTIAL <br />COMPLETION. <br />G. SPECIAL WARRANTIES SPECIFIED IN THIS THIS SECTION EXCLUDE <br />DETERIORATION OR FAILURE OF ELASTOMERIC SEALANT FROM THE <br />FOLLOWING: <br />1. MOVEMENT OF THE STRUCTURE FROM STRESSES ON THE <br />SEALANT THAT EXCEED THE SEALANT MANUFACTURERS <br />WRITTEN SPECIFICATIONS FOR SEALANT ELONGATION AND <br />COMPRESSION CAUSED BY STRUCTURAL SETTLEMENT OR <br />ERRORS ATTRIBUTABLE TO DESIGN AND CONSTRUCTION. <br />2. DISINTEGRATION OF JOINT SUBSTRATES FROM NATURAL <br />CAUSES EXCEEDING DESIGN SPECIFICATIONS. <br />3. MECHANICAL DAMAGE CAUSED BY INDIVIDUALS, TOOLS, OR <br />OTHER OUTSIDE AGENTS. <br />4. CHANGES IN THE SEALANT APPEARANCE CAUSED BY THE <br />ACCUMULATION OF DIRT OR OTHER ATMOSPHERIC <br />CONTAMINANTS. <br />PART2 PRODUCTS <br />2.01 EXTERIOR SEALANTS <br />A. PROVIDE ONE OR TWO COMPONENT ALIPHATIC URETHANE WHER <br />WHITE OR CUSTOM COLOR IS REQUIRED AND FOR VINYL TO VINYL <br />WITH PRIMER, MASONRY TO MASONRY INCLUDIING CONTROL JOINTS, <br />ALUMINUM TO MASONRY WITH PRIMER ON ALUMINUM AND FOR EIFS <br />APPLICATIONS. <br />1. USE ONE PRODUCT FOR THE ENTIRE JOB. <br />2. PRODUCTS: WHEN WHITE COLOR IS REQUIRED. <br />a. WHEN WHITE COLOR IS REQUIRED. ULTRA BY SONNEBORN <br />3. PROVIDE ONE OF THE FOLLOWING WHEN NON WHITE COLOR IS <br />SELECTED. <br />a. SONOLASTIC NP 2 BY SONNEBORN <br />b. DYNATROL II BY PECORA <br />c. CHE-CALK 500 BY BOSTIC <br />d. DYMERIC 511 BY TREMCO <br />B. PROVIDE ONE PART POLYETHER, MODIFIED SILICONE, <br />SIL-TERMINATED NON -SAG ELASTOMERIC SEALANT FOR METAL TO <br />METAL, METAL TO GLASS, GLASS TO GLASS, FERROUS METAL TO <br />VINYL, VINYL TO VINYL. <br />1. PRODUCTS: <br />a. SONOLASTIC 150 BY SONNEBORN <br />b. DOW CORNING 790 BY DOW CORNING <br />C. SILPUR SEALANT BY GE SILICONES <br />C. PROVIDE TWO PART POLYURETHANE SELF LEVLEING SEALANT FOR <br />EXTERIOR AND INTERIOR EXPANSION AND CONTROL JOINTS IN <br />HORIZONTAL WEARING SURFACES. <br />1. PRODUCTS <br />a. SONOLASTIC SL 2 BY SONNEBORN <br />b. DYNATRED BY PECORA <br />C. CHEM CALK 550 BY BOSTIK <br />D. PROVIDE ONE COMPONENT HIGH PERFORMANCE POLYURETHANE <br />SEALANT FOR INTERIOR SEALANT IN CONTACT WITH EXTERIOR <br />ALUMINUM STOREFRONT, DOORS AND FRAMES. <br />1. PRODUCTS <br />a. SONOLASTIC NP1 BY SONNEBORN <br />b. DYNATROL 1 BY PECORA <br />C. CHEM-CALK 2639 BY BOSTIK <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. VERIFY THAT SUBSTRATE SURFACES ARE READY TO RECEIVE WORK. <br />B. VERIFY THAT JOINT BACKING AND RELEASE TAPES ARE COMPATIBLE <br />WITH SEALANT. <br />3.02 PREPARATION <br />A. <br />REMOVE LOOSE MATERIALS AND FOREIGN MATTER WHICH MIGHT <br />IMPAIR ADHESION OF SEALANT. <br />B. <br />CLEAN AND PRIME JOINTS IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />C. <br />PERFORM PREPARATION IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS AND ASTM C 1193. <br />D. <br />PROTECT ELEMENTS SURROUNDING THE WORK OF THIS SECTION <br />FROM DAMAGE OR DISFIGUREMENT. <br />3.03 INSTALLATION <br />A. <br />PERFORM WORK IN ACCORDANCE WITH SEALANT MANUFACTURER'S <br />REQUIREMENTS FOR PREPARATION OF SURFACES AND MATERIAL <br />INSTALLATION INSTRUCTIONS. <br />B. <br />PERFORM INSTALLATION IN ACCORDANCE WITH ASTM C 1193. <br />C. <br />MEASURE JOINT DIMENSIONS AND SIZE JOINT BACKERS TO ACHIEVE <br />WIDTH -TO -DEPTH RATIO, NECK DIMENSION, AND SURFACE BOND <br />AREA AS RECOMMENDED BY MANUFACTURER. <br />D. <br />INSTALL BOND BREAKER WHERE JOINT BACKING IS NOT USED. E. <br />INSTALL SEALANT FREE OF AIR POCKETS, FOREIGN EMBEDDED <br />MATTER, RIDGES, AND SAGS. <br />F. <br />APPLY SEALANT WITHIN RECOMMENDED APPLICATION TEMPERATURE <br />RANGES. CONSULT MANUFACTURER WHEN SEALANT CANNOT BE <br />APPLIED WITHIN THESE TEMPERATURE RANGES. <br />G. <br />TOOL JOINTS CONCAVE. <br />3.04 CLEANING <br />A. <br />CLEAN ADJACENT SOILED SURFACES. <br />3.05 PROTECTION OF FINISHED WORK <br />A. <br />PROTECT SEALANTS UNTIL CURED. <br />END OF SECTION <br />/; <br />Z <br />O <br />1- <br />a <br />U <br />W <br />W <br />H <br />Q <br />W <br />.. 'e.'zf1 f'f ' <br />-i VJ <br />Z <br />O <br />UQ <br />Lu V <br />LL <br />=U <br />U/W <br />Q U) <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />PROJECT MANAGER DESIGNER <br />SS SS <br />JOB NO. <br />18390 <br />AS1 03 <br />