Laserfiche WebLink
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. <br />NON -FIRE -RATED STEEL DOORS AND FRAMES. <br />B. <br />STEEL FRAMES FOR WOOD DOORS. <br />C. <br />THERMALLY INSULATED STEEL DOORS. <br />D. <br />ACCESSORIES, INCLUDING GLAZING, LOUVERS, AND MATCHING <br />PANELS. <br />1.02 REFERENCES <br />A. <br />ANSI/ICC A117.1 - AMERICAN NATIONAL STANDARD FOR ACCESSIBLE <br />AND USABLE BUILDINGS AND FACILITIES, INTERNATIONAL CODE <br />COUNCIL, 1998. <br />B. <br />ANSI A250.8 - SDI-100 RECOMMENDED SPECIFICATIONS FOR <br />STANDARD STEEL DOORS AND FRAMES, 1998. <br />C. <br />ANSI A250.10 - TEST PROCEDURE AND ACCEPTANCE CRITERIA FOR <br />PRIME PAINTED STEEL SURFACES FOR STEEL DOORS AND FRAMES, <br />1998. <br />D. <br />ASTM A 653/A 653M - STANDARD SPECIFICATION FOR STEEL SHEET, <br />ZINC -COATED (GALVANIZED) OR ZINC -IRON ALLOY -COATED <br />(GALVANNEALED) BY THE HOT -DIP PROCESS, 2002A <br />E. <br />ASTM C 236 - STANDARD TEST METHOD FOR STEADY-STATE <br />THERMAL PERFORMANCE OF BUILDING ASSEMBLIES BY MEANS OF A <br />GUARDED HOT BOX, 1989 (REAPPROVED 1993). <br />F. <br />ASTM C 1363 - STANDARD TEST METHOD FOR THERMAL <br />PERFORMANCE OF BUILDING ASSEMBLIES BY MEANS OF A HOT BOX <br />APPARATUS, 1997. <br />G. <br />DHI A115 SERIES - SPECIFICATIONS FOR STEEL DOORS AND FRAME <br />PREPARATION FOR HARDWARE, DOOR AND HARDWARE INSTITUTE, <br />CURRENT EDITION (ANSI/DHI A115 SERIES). <br />H. <br />NAAMM HMMA 840 - INSTALLATION AND STORAGE OF HOLLOW METAL <br />DOORS AND FRAMES, THE NATIONAL ASSOCIATION OF <br />ARCHITECTURAL METAL MANUFACTURERS, 1999. <br />I. <br />NAAMM HMMA 860 - GUIDE SPECIFICATIONS FOR HOLLOW METAL <br />DOORS AND FRAMES, THE NATIONAL ASSOCIATION OF <br />ARCHITECTURAL METAL MANUFACTURERS, 1992. <br />J. <br />NFPA 80 - STANDARD FOR FIRE DOORS AND FIRE WINDOWS, <br />NATIONAL FIRE PROTECTION ASSOCIATION, 1999. <br />K. <br />NFPA 252 - STANDARD METHODS OF FIRE TESTS OF DOOR <br />ASSEMBLIES, NATIONAL FIRE PROTECTION ASSOCIATION, 1999. <br />L. <br />UL (BMD) - BUILDING MATERIALS DIRECTORY, UNDERWRITERS <br />LABORATORIES INC., CURRENT EDITION. <br />1.03 QUALITY ASSURANCE <br />A. <br />MAINTAIN AT THE PROJECT SITE A COPY OF ALL REFERENCE <br />STANDARDS DEALING WITH INSTALLATION. <br />1.04 DELIVERY, STORAGE, AND PROTECTION <br />A. <br />STORE IN ACCORDANCE WITH NAAMM HMMA 840. <br />B. <br />PROTECT WITH RESILIENT PACKAGING, AVOID HUMIDITY BUILD-UP <br />UNDER COVERINGS, PREVENT CORROSION. <br />PART 2 PRODUCTS <br />2.01 MANUFACTURERS <br />A. <br />STEEL DOORS AND FRAMES: <br />1. STEELCRAFT, PRODUCT BF16: WWW.STEELCRAFT.COM. <br />2. CECO DOOR PRODUCTS: WWW.CECODOOR.COM. <br />3. REPUBLIC BUILDERS PRODUCTS: <br />W W W. REPU BLICDOOR. COM. <br />4. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />2.02 DOORS AND FRAMES <br />A. <br />REQUIREMENTS FOR ALL DOORS AND FRAMES: <br />1. ACCESSIBILITY: COMPLY WITH ANSI/ICC A117.1. <br />2. DOOR TOP CLOSURES: EXTERIOR DOORS SHALL BE FLUSH <br />WITH TOP OF FACES AND EDGES. <br />3. DOOR EDGE PROFILE: BEVELED ON BOTH EDGES. <br />4. DOOR TEXTURE: SMOOTH FACES. <br />5. HARDWARE PREPARATION: IN ACCORDANCE WITH DHI A115 <br />SERIES, WITH REINFORCEMENT WELDED IN PLACE, IN <br />ADDITION TO OTHER REQUIREMENTS SPECIFIED IN DOOR <br />GRADE STANDARD. <br />6. GALVANIZING FOR EXTERIOR DOORS: ALL COMPONENTS <br />HOT -DIPPED ZINC -IRON ALLOY -COATED (GALVANNEALED), <br />MANUFACTURER'S STANDARD COATING THICKNESS. <br />7. FINISH: FACTORY PRIMED, FOR FIELD FINISHING. <br />B. <br />COMBINED REQUIREMENTS: IF A PARTICULAR DOOR AND FRAME <br />UNIT IS INDICATED TO COMPLY WITH MORE THAN ONE TYPE OF <br />REQUIREMENT, COMPLY WITH ALL THE SPECIFIED REQUIREMENTS <br />FOR EACH TYPE, FOR INSTANCE, AN EXTERIOR DOOR THAT IS ALSO <br />INDICATED AS BEING SOUND -RATED MUST COMPLY WITH THE <br />REQUIREMENTS SPECIFIED FOR EXTERIOR DOORS AND FOR <br />SOUND -RATED DOORS, WHERE TWO REQUIREMENTS CONFLICT, <br />COMPLY WITH THE MOST STRINGENT. <br />2.03 STEEL DOORS <br />A. <br />EXTERIOR DOORS: <br />1. GRADE: ANSI A250.8 LEVEL 3, MODEL 2, FULL FLUSH <br />SEAMLESS. <br />2. CORE: POLYURETHANE. <br />3. TOP AND BOTTOM CLOSURES: FLUSH WITH FACES AND <br />EDGES. <br />4. GALVANIZING: ALL COMPONENTS HOT -DIPPED ZINC -IRON <br />ALLOY -COATED (GALVANNEALED) IN ACCORDANCE WITH <br />ASTM A 653/A 653M, WITH MANUFACTURER'S STANDARD <br />COATING THICKNESS. <br />5. TEXTURE: SMOOTH FACES. <br />6. INSULATING VALUE: U-VALUE OF ,WHEN TESTED IN <br />ACCORDANCE WITH ASTM C 1363. <br />7. WEATHERSTRIPPING: SEPARATE, SEE SECTION 087100. <br />8. FINISH: FACTORY PRIMED, FOR FIELD FINISHING. <br />B. <br />INTERIOR DOORS: <br />1. GRADE: ANSI A250.8 LEVEL 2, MODEL 1, FLUSH. <br />2. GRADE: NAAMM HMMA 860, PHYSICAL PERFORMANCE LEVEL <br />A. <br />3. CORE: STEEL STIFFENERS. <br />4. THICKNESS: 1-3/4 INCHES (44 MM). <br />5. TEXTURE: SMOOTH FACES. <br />6. FINISH: FACTORY PRIMED, FOR FIELD FINISHING. <br />C. <br />PANELS: SAME CONSTRUCTION, PERFORMANCE, AND FINISH AS <br />DOORS. <br />2.04 STEEL FRAMES <br />A. <br />GENERAL: <br />1. COMPLY WITH THE REQUIREMENTS OF GRADE SPECIFIED <br />FOR CORRESPONDING DOOR. <br />a. ANSI A250.8 LEVEL 2 DOORS: 16 GAGE FRAMES; LEVEL 3 <br />DOOR 16 GA. <br />2. FINISH: SAME AS FOR DOOR. <br />3. PROVIDE MORTAR GUARD BOXES FOR HARDWARE CUT-OUTS <br />IN FRAMES TO BE INSTALLED IN MASONRY OR TO BE <br />GROUTED. <br />4. FRAMES IN MASONRY WALLS: SIZE TO SUIT MASONRY <br />COURSING WITH HEAD MEMBER TO FILL OPENING WITHOUT <br />CUTTING MASONRY UNITS. <br />B. <br />EXTERIOR DOOR FRAMES: FACE WELDED, SEAMLESS WITH JOINTS <br />FILLED. <br />1. GALVANIZING: ALL COMPONENTS HOT -DIPPED ZINC -IRON <br />ALLOY -COATED (GALVANNEALED) IN ACCORDANCE WITH <br />ASTM A 653/A 653M, WITH MANUFACTURER'S STANDARD <br />COATING THICKNESS. <br />2. WEATHERSTRIPPING: SEPARATE, SEE SECTION 087100. <br />C. INTERIOR DOOR FRAMES, FIRE -RATED: DRYWALL SLIP-ON TYPE OR <br />FACE WELDED AT MASONRY WALL CONSTRUCTION. <br />1. FIRE RATING: SAME AS DOOR, LABELED. <br />D. FRAMES FOR INTERIOR GLAZING OR BORROWED LIGHTS: <br />CONSTRUCTION AND FACE DIMENSIONS TO MATCH DOOR FRAMES, <br />AND AS INDICATED ON DRAWINGS. <br />2.05 METAL GATE <br />A. MANUFACTURER: iFENCE - INTEGRITY ALUMINUM PRODUCT <br />1. 38-1/2" WIDE x 36" HIGH ARCHED SINGLE LEAF GATE WITH <br />EVERBILT #276-490 SELF CLOSING HINGE. <br />2. FLUSH BOTTOM RAIL, 5/8" VERTICAL PICKETS, 3-13/16' CLEAR <br />BETWEEN PICKETS. <br />3. MATTE BLACK FINISH. <br />2.06 ACCESSORY MATERIALS <br />A. LOUVERS: ROLL FORMED STEEL WITH OVERLAPPING FRAME, <br />FACTORY -PAINTED FINISH, COLOR AS SELECTED, <br />FACTORY -INSTALLED. <br />1. IN FIRE -RATED DOORS: UL-LISTED FUSIBLE LINK LOUVER, <br />SAME RATING AS DOOR. <br />B. GROUT FOR FRAMES: PORTLAND CEMENT GROUT OF MAXIMUM <br />4-INCH SLUMP FOR HAND TROWELING, THINNER PUMPABLE GROUT <br />IS PROHIBITED. <br />C. SILENCERS: RESILIENT RUBBER, FITTED INTO DRILLED HOLE, 3 ON <br />STRIKE SIDE OF SINGLE DOOR, 3 ON CENTER MULLION OF PAIRS, <br />AND 2 ON HEAD OF PAIRS WITHOUT CENTER MULLIONS. <br />D. TEMPORARY FRAME SPREADERS: PROVIDE FOR ALL FACTORY- OR <br />SHOP -ASSEMBLED FRAMES. <br />2.07 FINISH MATERIALS <br />A. PRIMER: RUST -INHIBITING, COMPLYING WITH ANSI A250.10, DOOR <br />MANUFACTURER'S STANDARD. <br />B. BITUMINOUS COATING: ASPHALT EMULSION OR OTHER HIGH -BUILD, <br />WATER-RESISTANT, RESILIENT COATING. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK. <br />B. VERIFY THAT OPENING SIZES AND TOLERANCES ARE ACCEPTABLE. <br />3.02 PREPARATION <br />A. COAT INSIDE OF FRAMES TO BE INSTALLED IN MASONRY OR TO BE <br />GROUTED, WITH BITUMINOUS COATING, PRIOR TO INSTALLATION. <br />3.03 INSTALLATION <br />A. INSTALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE <br />SPECIFIED DOOR GRADE STANDARD AND NAAMM HMMA 840. <br />B. IN ADDITION, INSTALL FIRE RATED UNITS IN ACCORDANCE WITH <br />NFPA 80. <br />C. COORDINATE FRAME ANCHOR PLACEMENT WITH WALL <br />CONSTRUCTION. <br />D. GROUT FRAMES IN MASONRY CONSTRUCTION, USING HAND TROWEL <br />METHODS, BRACE FRAMES SO THAT PRESSURE OF GROUT BEFORE <br />SETTING WILL NOT DEFORM FRAMES. SET FOAM SPACERS BLOCK AT <br />SILENCER HOLES. <br />E. COORDINATE INSTALLATION OF HARDWARE. <br />F. COORDINATE INSTALLATION OF GLAZING. <br />3.04 ERECTION TOLERANCES <br />A. CLEARANCES BETWEEN DOOR AND FRAME: AS SPECIFIED IN ANSI <br />A250.8. <br />B. MAXIMUM DIAGONAL DISTORTION: 1/16 IN (1.5 MM) MEASURED WITH <br />STRAIGHT EDGE, CORNER TO CORNER. <br />3.05 ADJUSTING <br />A. ADJUST FOR SMOOTH AND BALANCED DOOR MOVEMENT. <br />3.06 SCHEDULE <br />A. REFER TO DOOR AND FRAME SCHEDULE ON THE DRAWINGS. <br />END OF SECTION <br />SECTION 081416 - FLUSH WOOD DOORS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. FLUSH WOOD DOORS, FLUSH CONFIGURATION, FIRE RATED AND <br />NON -RATED. <br />1.02 REFERENCES <br />A. AWI (QSI) - ARCHITECTURAL WOODWORK QUALITY STANDARDS <br />ILLUSTRATED, ARCHITECTURAL WOODWORK INSTITUTE, 1997, <br />SEVENTH EDITION, VERSION 1.0. <br />B. WDMA NWWDA I.S.1-A - ARCHITECTURAL WOOD FLUSH DOORS, <br />WINDOW AND DOOR MANUFACTURERS ASSOCIATION (FORMERLY <br />NWWDA), 1997. <br />1.03 SUBMITTALS <br />A. SEE SECTION 013000 -ADMINISTRATIVE REQUIREMENTS FOR <br />SUBMITTAL PROCEDURES. <br />B. PRODUCT DATA: INDICATE DOOR CORE MATERIALS AND <br />CONSTRUCTION, VENEER SPECIES, TYPE AND CHARACTERISTICS. <br />1.04 QUALITY ASSURANCE <br />A. MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING THE <br />PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE <br />YEARS OF DOCUMENTED EXPERIENCE. <br />1.05 DELIVERY, STORAGE, AND PROTECTION <br />A. PACKAGE, DELIVER AND STORE DOORS IN ACCORDANCE WITH <br />SPECIFIED QUALITY STANDARD. <br />B. ACCEPT DOORS ON SITE IN MANUFACTURER'S PACKAGING. INSPECT <br />FOR DAMAGE. <br />C. PROTECT DOORS WITH RESILIENT PACKAGING SEALED WITH HEAT <br />SHRUNK PLASTIC. DO NOT STORE IN DAMP OR WET AREAS, OR IN <br />AREAS WHERE SUNLIGHT MIGHT BLEACH VENEER. SEAL TOP AND <br />BOTTOM EDGES WITH TINTED SEALER IF STORED MORE THAN ONE <br />WEEK. BREAK SEAL ON SITE TO PERMIT VENTILATION. <br />1.06 PROJECT CONDITIONS <br />A. COORDINATE THE WORK WITH DOOR OPENING CONSTRUCTION, <br />DOOR FRAME AND DOOR HARDWARE INSTALLATION. <br />1.07 WARRANTY <br />A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS FOR ADDITIONAL <br />WARRANTY REQUIREMENTS. <br />B. PROVIDE WARRANTY FOR THE FOLLOWING TERM: <br />1. INTERIOR DOORS: TWO (2) YEARS. <br />C. INCLUDE COVERAGE FOR DELAMINATION OF VENEER, WARPING <br />BEYOND SPECIFIED INSTALLATION TOLERANCES, DEFECTIVE <br />MATERIALS, AND TELEGRAPHING CORE CONSTRUCTION <br />PART 2 PRODUCTS <br />2.01 DOORS AND PANELS <br />A. ALL DOORS: SEE DRAWINGS FOR LOCATIONS AND ADDITIONAL <br />REQUIREMENTS. <br />1. QUALITY STANDARD: WDMA I.S. 1-A, ECONOMY GRADE. <br />2. WOOD VENEER FACED DOORS: 5-PLY UNLESS OTHERWISE <br />INDICATED. <br />B. INTERIOR DOORS: 1-3/4 INCHES (44 MM) THICK UNLESS OTHERWISE <br />INDICATED, FLUSH CONSTRUCTION. <br />1. PROVIDE SOLID CORE DOORS AT ALL LOCATIONS EXCEPT <br />PROVIDE HOLLOW CORE DOORS AT LOCATIONS INDICATED <br />ON DRAWINGS. <br />2.02 DOOR AND PANEL CORES <br />A. NON -RATED SOLID CORE AND 20 MINUTE RATED DOORS: TYPE SLC, <br />STAVED LUMBER CORE, PLIES AND FACES AS INDICATED ABOVE. <br />B. HOLLOW CORE DOORS: TYPE SHC - STANDARD, PLIES AND FACES <br />AS INDICATED ABOVE. <br />2.03 DOOR FACINGS <br />A. WOOD VENEER FACING FOR TRANSPARENT FINISH: NATURAL BIRCH, <br />VENEER GRADE AS SPECIFIED BY QUALITY STANDARD, QUARTER <br />SLICED, BOOK VENEER MATCH, RUNNING ASSEMBLY MATCH, UNLESS <br />OTHERWISE INDICATED. <br />1. VERTICAL EDGES: COMPATIBLE HARDWOOD. <br />B. VENEER FACING FOR OPAQUE FINISH: MEDIUM DENSITY OVERLAID <br />PLYWOOD. <br />2.04 ACCESSORIES <br />2.05 DOOR CONSTRUCTION <br />A. FABRICATE DOORS IN ACCORDANCE WITH DOOR QUALITY <br />STANDARD SPECIFIED. <br />B. PROVIDE SOLID BLOCKS AT LOCK EDGE FOR HARDWARE <br />REINFORCEMENT. <br />C. FIT DOOR EDGE TRIM TO EDGE OF STILES AFTER APPLYING VENEER <br />FACING. <br />D. PROVIDE EDGE CLEARANCES IN ACCORDANCE WITH AWI QUALITY <br />STANDARDS ILLUSTRATED SECTION 1700. <br />2.06 FACTORY FINISHING <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK. <br />B. VERIFY THAT OPENING SIZES AND TOLERANCES ARE ACCEPTABLE. <br />C. DO NOT INSTALL DOORS IN FRAME OPENINGS THAT ARE NOT PLUMB <br />OR ARE OUT -OF -TOLERANCE FOR SIZE OR ALIGNMENT. <br />3.02 INSTALLATION <br />A. INSTALL DOORS IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS AND SPECIFIED QUALITY STANDARD. <br />B. TRIM NON -RATED DOOR WIDTH BY CUTTING EQUALLY ON BOTH JAMB <br />EDGES. <br />C. TRIM DOOR HEIGHT BY CUTTING BOTTOM EDGES TO A MAXIMUM OF <br />3/4 INCH (19 MM). <br />D. USE MACHINE TOOLS TO CUT OR DRILL FOR HARDWARE. <br />E. COORDINATE INSTALLATION OF DOORS WITH INSTALLATION OF <br />FRAMES AND HARDWARE. <br />F. COORDINATE INSTALLATION OF GLAZING. <br />G. INSTALL DOOR LOUVERS PLUMB AND LEVEL. <br />3.03 INSTALLATION TOLERANCES <br />A. CONFORM TO SPECIFIED QUALITY STANDARD FOR FIT AND <br />CLEARANCE TOLERANCES. <br />B. CONFORM TO SPECIFIED QUALITY STANDARD FOR MAXIMUM <br />DIAGONAL DISTORTION. <br />3.04 ADJUSTING <br />A. ADJUST DOORS FOR SMOOTH AND BALANCED DOOR MOVEMENT. <br />B. ADJUST CLOSERS FOR FULL CLOSURE. <br />3.05 SCHEDULE - SEE DRAWINGS <br />END OF SECTION <br />SECTION 083613 - SECTIONAL DOORS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. STEEL SECTIONAL OVERHEAD DOORS. <br />B. ELECTRIC OPERATORS AND CONTROLS. <br />C. OPERATING HARDWARE, TRACKS, AND SUPPORT. <br />1.02 REFERENCES <br />A. ANSUDASMA 102 AMERICAN NATIONAL STANDARD SPECIFICATIONS <br />FOR SECTIONAL OVERHEAD TYPE DOORS. <br />1.03 SUBMITTALS <br />A. SEE SECTION 013000 -ADMINISTRATIVE REQUIREMENTS, FOR <br />SUBMITTAL PROCEDURES. <br />B. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH <br />PRODUCT TO BE USED, INCLUDING: <br />1. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS. <br />2. STORAGE AND HANDLING REQUIREMENTS AND <br />RECOMMENDATIONS. <br />3. INSTALLATION METHODS. <br />C. SHOP DRAWINGS: INDICATE PLANS AND ELEVATIONS INCLUDING <br />OPENING DIMENSIONS AND REQUIRED TOLERANCES, CONNECTION <br />DETAILS, ANCHORAGE SPACING, HARDWARE LOCATIONS, AND <br />INSTALLATION DETAILS. <br />D. MANUFACTURER'S CERTIFICATES: CERTIFY PRODUCTS MEET OR <br />EXCEED SPECIFIED REQUIREMENTS. <br />E. OPERATION AND MAINTENANCE DATA. <br />1.04 QUALITY ASSURANCE <br />A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN <br />MANUFACTURING PRODUCTS SPECIFIED IN THIS SECTION WITH <br />MINIMUM FIVE YEARS DOCUMENTED EXPERIENCE. <br />B. INSTALLER QUALIFICATIONS: AUTHORIZED REPRESENTATIVE OF THE <br />MANUFACTURER WITH MINIMUM FIVE YEARS DOCUMENTED <br />EXPERIENCE. <br />C. PRODUCTS REQUIRING ELECTRICAL CONNECTION: LISTED AND <br />CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. ACCEPTABLE <br />TO AUTHORITY HAVING JURISDICTION AS SUITABLE FOR PURPOSE <br />SPECIFIED. <br />1.05 DELIVERY, STORAGE, AND HANDLING <br />A. STORE PRODUCTS IN MANUFACTURER'S UNOPENED LABELED <br />PACKAGING UNTIL READY FOR INSTALLATION. <br />B. PROTECT MATERIALS FROM EXPOSURE TO MOISTURE UNTIL READY <br />FOR INSTALLATION. <br />C. STORE MATERIALS IN A DRY, VENTILATED WEATHERTIGHT LOCATION <br />1.06 PROJECT CONDITIONS <br />A. PRE -INSTALLATION CONFERENCE: CONVENE A PRE -INSTALLATION <br />CONFERENCE JUST PRIOR TO COMMENCEMENT OF FIELD <br />OPERATIONS, TO ESTABLISH PROCEDURES TO MAINTAIN OPTIMUM <br />WORKING CONDITIONS AND TO COORDINATE THIS WORK WITH <br />RELATED AND ADJACENT WORK. <br />PART 2 PRODUCTS. <br />2.01 MANUFACTURERS <br />A. ACCEPTABLE MANUFACTURER: OVERHEAD DOOR CORP., 2501 S <br />STATE HWY. 121, SUITE 200, LEWISVILLE, TX 75067. ASD. TEL TOLL <br />FREE: (800) 275-3290. PHONE: (469) 549-7100. FAX: (972) 906-1499. WEB <br />SITE: WWW.OVERHEADDOOR.COM E-MAIL: <br />SALES@OVERHEADDOOR.COM <br />B. REQUESTS FOR SUBSTITUTIONS WILL BE CONSIDERED IN <br />ACCORDANCE WITH PROVISIONS OF SECTION 016000. <br />2.02 SECTIONAL OVERHEAD DOORS <br />A. SECTIONAL OVERHEAD STEEL DOORS: 418 SERIES STEEL DOORS BY <br />OVERHEAD DOOR CORPORATION. UNITS SHALL HAVE THE <br />FOLLOWING CHARACTERISTICS: <br />1. DOOR ASSEMBLY: INSULATED STEEL DOOR ASSEMBLY WITH <br />RABBETED MEETING RAILS TO FORM WEATHER TIGHT JOINTS <br />AND PROVIDE FULL -WIDTH INTERLOCKING STRUCTURAL <br />RIGIDITY. <br />a. PANEL THICKNESS: 2 INCHES (51 MM). <br />b. EXTERIOR SURFACE: FLUSH. <br />c. THERMAL VALUES: R-VALUE OF 7.35; U-VALUE OF 0.17. <br />d. SECTION MATERIAL: 16 GAUGE, GALVANIZED STEEL. <br />e. CENTER AND END STILES: 16 GAUGE STEEL. <br />f. SPRINGS: <br />1.)10,000 CYCLES. <br />2. LOCK: <br />a. INTERIOR MOUNTED SLIDE LOCK. <br />3. WEATHERSTRIPPING: <br />a. FLEXIBLE BULB -TYPE STRIP AT BOTTOM SECTION. <br />b. FLEXIBLE JAMB SEALS. <br />c. FLEXIBLE HEADER SEAL. <br />4. TRACK: PROVIDE TRACK AS RECOMMENDED BY <br />MANUFACTURER TO SUIT LOADING REQUIRED AND <br />CLEARANCES AVAILABLE. <br />5. MANUAL OPERATION: PULL ROPE. <br />6. ELECTRIC MOTOR OPERATION: PROVIDE UL LISTED ELECTRIC <br />OPERATOR, SIZE AND TYPE AS RECOMMENDED BY <br />MANUFACTURER TO MOVE DOOR IN EITHER DIRECTION AT <br />NOT LESS THAN 2/3 FOOT NOR MORE THAN 1 FOOT PER <br />SECOND. OPERATOR SHALL MEET UL325/2010 <br />REQUIREMENTS FOR CONTINUOUS MONITORING OF SAFETY <br />DEVICES. <br />a. ENTRAPMENT PROTECTION: REQUIRED FOR MOMENTARY <br />CONTACT, INCLUDES RADIO CONTROL OPERATION. <br />1.) PNEUMATIC SENSING EDGE UP TO 18 FEET <br />(5.5 M) WIDE. CONSTANT CONTACT ONLY <br />COMPLYING WITH UL 325/2010. <br />2.) OPERATOR CONTROLS: <br />PUSH-BUTTON AND KEY OPERATED CONTROL <br />STATIONS WITH OPEN, CLOSE, AND STOP <br />BUTTONS. SURFACE MOUNTING. INTERIOR <br />LOCATION. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />DO NOT BEGIN INSTALLATION UNTIL OPENINGS HAVE BEEN <br />PROPERLY PREPARED. <br />B. <br />VERIFY WALL OPENINGS ARE READY TO RECEIVE WORK AND <br />OPENING DIMENSIONS AND TOLERANCES ARE WITHIN SPECIFIED <br />LIMITS. <br />C. <br />VERIFY ELECTRICAL POWER IS AVAILABLE AND OF CORRECT <br />CHARACTERISTICS. <br />3.02 PREPARATION <br />A. <br />CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION. <br />B. <br />PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE <br />MANUFACTURER FOR ACHIEVING THE BEST RESULTS FOR THE <br />SUBSTRATE UNDER THE PROJECT CONDITIONS. <br />3.03 INSTALLATION <br />A. <br />INSTALL OVERHEAD DOORS AND TRACK IN ACCORDANCE WITH <br />APPROVED SHOP DRAWINGS AND THE MANUFACTURER'S PRINTED <br />INSTRUCTIONS.. <br />B. <br />COORDINATE INSTALLATION WITH ADJACENT WORK TO ENSURE <br />PROPER CLEARANCES AND ALLOW FOR MAINTENANCE. <br />C. <br />ANCHOR ASSEMBLY TO WALL CONSTRUCTION AND BUILDING <br />FRAMING WITHOUT DISTORTION OR STRESS. <br />D. <br />SECURELY BRACE DOOR TRACKS SUSPENDED FROM STRUCTURE. <br />SECURE TRACKS TO STRUCTURAL MEMBERS ONLY. <br />E. <br />FIT AND ALIGN DOOR ASSEMBLY INCLUDING HARDWARE. <br />F. <br />COORDINATE INSTALLATION OF ELECTRICAL SERVICE. COMPLETE <br />POWER AND CONTROLS WIRING FROM DISCONNECT TO UNIT <br />COMPONENTS.. <br />3.04 CLEANING AND ADJUSTING <br />A. <br />ADJUST DOORS ASSEMBLY TO SMOOTH OPERATION AND IN FULL <br />CONTACT WITH WEATHERSTRIPPING. <br />B. <br />CLEAN DOORS, FRAMES AND GLASS. <br />C. <br />REMOVE TEMPORARY LABELS AND VISIBLE MARKINGS. <br />3.05 PROTECTION OF FINISHED WORK <br />A. <br />DO NOT PERMIT CONSTRUCTION TRAFFIC THROUGH OVERHEAD <br />DOOR OPENINGS AFTER ADJUSTMENT AND CLEANING. <br />B. <br />PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT. <br />C. <br />TOUCH-UP DAMAGED COATINGS AND FINISHES AND REPAIR DAMAGE <br />BEFORE SUBSTANTIAL COMPLETION. <br />END OF SECTION <br />SECTION 084113 - ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. <br />ALUMINUM -FRAMED STOREFRONT, WITH VISION GLASS. <br />B. <br />WEATHERSTRIPPING. <br />C. <br />PERIMETER SEALANT. <br />1.02 RELATED SECTIONS <br />A. <br />SECTION 079200 - JOINT SEALERS: PERIMETER SEALANT AND <br />BACK-UP MATERIALS. <br />B. <br />SECTION 088000 - GLAZING: GLASS AND GLAZING ACCESSORIES. <br />1.03 REFERENCES <br />A. <br />AA DAF-45 - DESIGNATION SYSTEM FOR ALUMINUM FINISHES, THE <br />ALUMINUM ASSOCIATION, INC., 2003. <br />B. <br />AAMA CW-10 - CARE AND HANDLING OF ARCHITECTURAL ALUMINUM <br />FROM SHOP TO SITE, AMERICAN ARCHITECTURAL MANUFACTURERS <br />ASSOCIATION, 1997. <br />C. <br />AAMA 611 - VOLUNTARY SPECIFICATION FOR ANODIZED <br />ARCHITECTURAL ALUMINUM, AMERICAN ARCHITECTURAL <br />MANUFACTURERS ASSOCIATION, 1998. <br />D. <br />ASTM B 221 - STANDARD SPECIFICATION FOR ALUMINUM AND <br />ALUMINUM -ALLOY EXTRUDED BARS, RODS, WIRE, PROFILES, AND <br />TUBES, 2002. <br />E. <br />ASTM B 221 M - STANDARD SPECIFICATION FOR ALUMINUM AND <br />ALUMINUM -ALLOY EXTRUDED BARS, RODS, WIRE, PROFILES, AND <br />TUBES (METRIC), 2002. <br />1.04 SUBMITTALS <br />A. <br />SEE SECTION 013000 -ADMINISTRATIVE REQUIREMENTS, FOR <br />SUBMITTAL PROCEDURES. <br />B. <br />PRODUCT DATA: PROVIDE COMPONENT DIMENSIONS, DESCRIBE <br />COMPONENTS WITHIN ASSEMBLY, ANCHORAGE AND FASTENERS, <br />GLASS AND INFILL, DOOR HARDWARE, INTERNAL DRAINAGE DETAILS. <br />C. <br />SHOP DRAWINGS: INDICATE SYSTEM DIMENSIONS, FRAMED <br />OPENING REQUIREMENTS AND TOLERANCES, AFFECTED RELATED <br />WORK, EXPANSION AND CONTRACTION JOINT LOCATION AND <br />DETAILS, AND FIELD WELDING REQUIRED. <br />D. <br />WARRANTY: SUBMIT MANUFACTURER WARRANTY AND ENSURE <br />FORMS HAVE BEEN COMPLETED IN DEVELOPERS DIVERSIFIED'S <br />NAME AND REGISTERED WITH MANUFACTURER. <br />1.05 DELIVERY, STORAGE, AND PROTECTION <br />A. <br />HANDLE PRODUCTS OF THIS SECTION IN ACCORDANCE WITH AAMA <br />CW-10. <br />B. <br />PROTECT FINISHED ALUMINUM SURFACES WITH WRAPPING. DO NOT <br />USE ADHESIVE PAPERS OR SPRAYED COATINGS WHICH BOND TO <br />ALUMINUM WHEN EXPOSED TO SUNLIGHT OR WEATHER. <br />1.06 PROJECT CONDITIONS <br />A. COORDINATE THE WORK WITH INSTALLATION OF FIRESTOPPING <br />COMPONENTS OR MATERIALS. <br />1.07 WARRANTY <br />A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL <br />WARRANTY REQUIREMENTS. <br />B. PROVIDE FIVE YEAR MANUFACTURER WARRANTY AGAINST FAILURE <br />OF GLASS SEAL ON INSULATING GLASS UNITS, INCLUDING <br />INTERPANE DUSTING OR MISTING. INCLUDE PROVISION FOR <br />REPLACEMENT OF FAILED UNITS. <br />C. PROVIDE FIVE YEAR MANUFACTURER WARRANTY AGAINST <br />EXCESSIVE DEGRADATION OF EXTERIOR FINISH. INCLUDE <br />PROVISION FOR REPLACEMENT OF UNITS WITH EXCESSIVE FADING, <br />CHALKING, OR FLAKING. <br />PART 2 PRODUCTS <br />2.01 MANUFACTURERS <br />A. ACCEPTABLE MANUFACTURERS - STOREFRONT SYSTEM: <br />1. KAWNEER COMPANY, INC, PRODUCT TRI-FAB VG- 451T AT <br />EXTERIOR AND TRI-FAB 450 FOR INTERIOR APPLICATIONS: <br />WWW.KAWNEER.COM. <br />2. UNITED STATES ALUMINUM CORP: WWW.USALUM.COM. <br />3. VISTAWALL ARCHITECTURAL PRODUCTS: <br />WWW.VISTAWALL.COM. <br />4. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />2.02 COMPONENTS <br />A. ALUMINUM -FRAMED STOREFRONT: FACTORY FABRICATED, <br />FACTORY FINISHED ALUMINUM FRAMING MEMBERS WITH INFILL, AND <br />RELATED FLASHINGS, ANCHORAGE AND ATTACHMENT DEVICES. <br />1. FINISH: CLASS I COLOR ANODIZED AT INTERIOR, OR TO <br />MATCH EXISTING FINISH AS INDICATED ON DRAWINGS. <br />2.03 MATERIALS <br />A. EXTRUDED ALUMINUM: ASTM B 221 (ASTM B 221 M). <br />B. FASTENERS: STAINLESS STEEL. <br />C. EXPOSED FLASHINGS: 0.032 INCH (0.8 MM) THICK ALUMINUM SHEET, <br />FINISH TO MATCH FRAMING MEMBERS. <br />D. CONCEALED FLASHINGS: 0.018 INCH (0.5 MM) THICK GALVANIZED <br />STEEL. <br />E. PERIMETER SEALANT: TYPE SPECIFIED IN SECTION 079200. <br />F. GLASS: AS SPECIFIED IN SECTION 088000. <br />1. GLASS IN EXTERIOR FRAMING: TYPE INSULATED UNITS. <br />2.04 FINISHES <br />A. <br />COMPLY WITH AA DAF-45 FOR ALUMINUM FINISHES REQUIRED. <br />B. <br />CLASS I COLOR ANODIZED FINISH: ANODIC COATING TO MATCH <br />EXISTING, NOT LESS THAN 0.7 MILS (0.018 MM) THICK. <br />C. <br />TOUCH-UP MATERIALS: AS RECOMMENDED BY COATING <br />MANUFACTURER FOR FIELD APPLICATION. <br />2.05 HARDWARE <br />2.06 FABRICATION <br />A. <br />FABRICATE COMPONENTS WITH MINIMUM CLEARANCES AND SHIM <br />SPACING AROUND PERIMETER OF ASSEMBLY, YET ENABLING <br />INSTALLATION AND DYNAMIC MOVEMENT OF PERIMETER SEAL. <br />B. <br />ACCURATELY FIT AND SECURE JOINTS AND CORNERS. MAKE JOINTS <br />FLUSH, HAIRLINE, AND WEATHERPROOF. <br />C. <br />PREPARE COMPONENTS TO RECEIVE ANCHOR DEVICES. FABRICATE <br />ANCHORS. <br />D. <br />COAT CONCEALED METAL SURFACES THAT WILL BE IN CONTACT <br />WITH CEMENTITIOUS MATERIALS OR DISSIMILAR METALS WITH <br />BITUMINOUS PAINT. <br />E. <br />ARRANGE FASTENERS AND ATTACHMENTS TO CONCEAL FROM VIEW. <br />F. <br />REINFORCE FRAMING MEMBERS FOR IMPOSED LOADS. <br />G. <br />FINISHING: APPLY FACTORY FINISH TO ALL SURFACES THAT WILL BE <br />EXPOSED IN COMPLETED ASSEMBLIES. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />VERIFY DIMENSIONS, TOLERANCES, AND METHOD OF ATTACHMENT <br />WITH OTHER WORK. <br />B. <br />VERIFY THAT WALL OPENINGS AND ADJOINING AIR AND VAPOR SEAL <br />MATERIALS ARE READY TO RECEIVE WORK OF THIS SECTION. <br />3.02 INSTALLATION <br />A. <br />INSTALL WALL SYSTEM IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />B. <br />ATTACH TO STRUCTURE TO PERMIT SUFFICIENT ADJUSTMENT TO <br />ACCOMMODATE CONSTRUCTION TOLERANCES AND OTHER <br />IRREGULARITIES. <br />C. <br />PROVIDE ALIGNMENT ATTACHMENTS AND SHIMS TO PERMANENTLY <br />FASTEN SYSTEM TO BUILDING STRUCTURE. <br />D. <br />ALIGN ASSEMBLY PLUMB AND LEVEL, FREE OF WARP OR TWIST. <br />MAINTAIN ASSEMBLY DIMENSIONAL TOLERANCES, ALIGNING WITH <br />ADJACENT WORK. <br />E. <br />PROVIDE THERMAL ISOLATION WHERE COMPONENTS PENETRATE <br />OR DISRUPT BUILDING INSULATION. <br />F. <br />INSTALL SILL FLASHINGS. TURN UP ENDS AND EDGES, SEAL TO <br />ADJACENT WORK TO FORM WATER TIGHT DAM. <br />G. <br />COORDINATE ATTACHMENT AND SEAL OF PERIMETER AIR AND <br />VAPOR BARRIER MATERIALS. <br />H. <br />PACK FIBROUS INSULATION IN SHIM SPACES AT PERIMETER OF <br />ASSEMBLY TO MAINTAIN CONTINUITY OF THERMAL BARRIER. <br />1. <br />INSTALL HARDWARE USING TEMPLATES PROVIDED. <br />J. <br />INSTALL GLASS IN ACCORDANCE WITH SECTION 088000, USING <br />GLAZING METHOD REQUIRED TO ACHIEVE PERFORMANCE CRITERIA. <br />K. <br />INSTALL PERIMETER SEALANT IN ACCORDANCE WITH SECTION <br />079200. <br />3.03 ERECTION TOLERANCES <br />A. <br />MAXIMUM VARIATION FROM PLUMB: 0.06 INCHES EVERY 3 FT (1.5 <br />MM/M) NON -CUMULATIVE OR 1/16 INCHES PER 10 FT (1.5 MM/3 M), <br />WHICHEVER IS LESS. <br />B. <br />MAXIMUM MISALIGNMENT OF TWO ADJOINING MEMBERS ABUTTING <br />IN PLANE: 1/32 INCH (0.8 MM). <br />3.04 ADJUSTING <br />A. <br />ADJUST OPERATING HARDWARE FOR SMOOTH OPERATION. <br />3.05 CLEANING AND PROTECTION <br />A. <br />REMOVE PROTECTIVE MATERIAL FROM PRE -FINISHED ALUMINUM <br />SURFACES. <br />B. <br />WASH DOWN SURFACES WITH A SOLUTION OF MILD DETERGENT IN <br />WARM WATER, APPLIED WITH SOFT, CLEAN WIPING CLOTHS. TAKE <br />CARE TO REMOVE DIRT FROM CORNERS. WIPE SURFACES CLEAN. <br />C. <br />REMOVE EXCESS SEALANT BY METHOD ACCEPTABLE TO SEALANT <br />MANUFACTURER. <br />D. <br />TOUCH-UP MINOR DAMAGE TO FACTORY APPLIED FINISH, REPLACE <br />COMPONENTS THAT CANNOT BE SATISFACTORILY REPAIRED. <br />E. <br />PROTECT FINISHED WORK FROM DAMAGE. <br />END OF SECTION <br />O <br />H <br />a <br />U <br />W <br />W <br />Q <br />0 <br />W <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />JOB NO. <br />18390 <br />AS1 m4 <br />