Laserfiche WebLink
SECTION 084229 -AUTOMATIC ENTRANCES <br />PART 1 <br />1.01 SECTION INCLUDES <br />A. SLIDING AUTOMATIC ENTRANCES <br />1.02 RELATED SECTIONS <br />A. DIVISION 7 FOR CAULKING <br />B. DIVISION 8 FOR DOOR HARDWARE <br />C. DIVISION 26 FOR ELECTRICAL CONNECTIONS <br />1.03 REFERENCES <br />A. UL 325 - STANDARD FOR DOOR, DRAPERY, GATE,LIOUVER, AND <br />WINDOW OPERATORS AND SYSTEMS <br />B. ANSI/BMHA Al56.10: STANDARD FOR POWER OPERATED PEDESTRIAN <br />DOORS <br />C. ANSI/BMHA A156.5: STANDARD FOR AUXILIARY LOCKS AND <br />ASSOCIATED PRODUCTS <br />D. ANSI Z97.1: STANDARDS FOR SAFETY GLAZING MATERIALS USED IN <br />BUILDINGS - SAFETY PERFORMANCE SPECIFICATIONS AND METHODS <br />E. CPSC 16 CFR 1201: SAFETY STANDARD FOR ARCHITECTURAL <br />GLAZING MATERIALS <br />F. ASTM B221 - STANDARD SPECIFICATION FOR ALUMINUM EXTRUDED <br />BARS, RODS, WIRE, PROFILES, AND TUBES <br />G. ASTM B209 - STANDARD SPECIFICATION FOR ALUMINUM SHEET AND <br />PLATE <br />H. AAMA 611 -VOLUNTARY SPECIFICATION FOR ANODIZED <br />ARCHITECTURAL ALUMINUM, AMERICAN ARCHITECTURAL <br />MANUFACTURERS ASSOCIATION, 1998 <br />I. AAMA 701 - VOLUNTARY SPECIFICATION FOR PILE <br />WEATHERSTRIPPING AND REPLACEABLE FENESTRATION <br />WEATHERSEALS <br />1.04 SUBMITTALS <br />A. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, <br />DETAILS, HARDWARE MOUNTING HEIGHTS, AND ATTACHMENTS TO <br />OTHER WORK. <br />B. COLOR SAMPLES FOR SELECTION OF FCATORY-APPLIED COLOR <br />FINISHES. <br />C. CLOSEOUT SUBMITTALS: OWNER'S MANUAL AND WARRANTIES <br />1.05 WARRANTY <br />A. AUTOMATIC ENTRANCES SHALL BE FREE OF DEFECTS IN MATERIAL <br />AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF <br />SUBSTANTIAL COMPLETION. <br />PART 2 PRODUCTS <br />2.01 AUTOMATIC ENTRANCES <br />A. MANUFACTURER: RECORD AUTOMATIC DOOR SYSTEMS <br />(RECORD -USA): SERIES 5100 SIZE: AS INDICATED ON DRAWINGS. <br />BI-PART DOOR PACKAGE <br />B. SUBSTITUTIONS: SEE DIVISION 1 FOR SUBSTITUTION PROCEDURES <br />2.02 MATERIALS <br />A. ALUMINUM <br />A.A. HEADERS, STILES, RAILS AND FRAMES: 6063-T6 <br />A.B. EXTRUDED BARS, RODS, PROFILES AND TUBES: ASTM B 221 <br />A.C. SHEET AND PLATE: ASTM B 209 <br />B. SEALANTS AND JOINT FILLERS: SEE DIVISION 7 SECTION JOINT <br />SEALANTS <br />2.03 COMPONENTS <br />A. FRAMING AND TENSION MEMBERS: NOMINAL SIZE 1 3/4" X 4 1/2" WITH <br />CONCEALED FASTENERS. TRANSOM SHALL BE INTEGRAL TO SLIDING <br />DOOR FRAMING SYSTEM WITH FLUSH GLAZING. <br />B. STILE AND RAIL DOORS AND SIDELIGHTS: 1 3/4" THICK GLAZED <br />DOORS WITH EXTRUDED ALUMINUM TUBULAR STILE AND RAIL <br />MEMBERS. SNAP ON GLAZING STOPS AND GASKETS. 2" NOMINAL <br />WIDTH NARROW STILE. MINIMUM 10" NOMINAL HEIGHT ON BOTTOM <br />RAIL DESIGN. HORIZONTAL TUBULAR RAIL MEMBER FOR EACH DOOR, <br />2" NOMINAL WIDTH <br />C. GLAZING: 1" CLEAR IG ON EXTERIOR DOOR PACKAGE, 1/4" CLEAR <br />TEMP ON INTERIOR DOOR PACKAGE. <br />D. HEADERS: CONCEALED MOUNTING WITH ONE SIDE OF HEADER <br />FLUSH WITH FRAMING. CAPABLE OF SUPPORTING UP TO 220 LBS PER <br />PANEL, UP TO 4 PANELS, OVER SPANS OF 14 FEET WITHOUT <br />INTERMEDIATE SUPPORTS <br />E. CARRIER ASSEMBLIES AND OVERHEAD ROLLER TRACKS: <br />MANUFACTURER'S STANDARD CARRIER PACKAGE <br />F. THRESHOLDS: CONTINUOUS STANDARD TAPERED EXTRUSION <br />DOUBLE BEVEL <br />G. FASTENERS: STANDARD CORROSION RESISTANT, NON -STAINING, <br />NON -BLEEDING <br />2.04 ELECTRICAL CONTROLS <br />A. MICROPROCESSOR CONTROLLER AND POSITION ENCODER WITH <br />SAFETY LOGIC AND WATCHDOG LED <br />2.05 ACTIVATION AND SAFETY DEVICES <br />A. DUAL ACTIVATION STANLEY SU-100 MOTION SENSOR SHALL BE <br />MOUNTED ON EACH SIDE OF THE DOOR HEADER <br />B. STAN GUARD THRESHOLD SAFETY SENSORS SHALL BE PROVIDED <br />C. PHOTO -ELECTRONIC BEAMS SHALL BE PULSED INFRARED TYPE <br />2.06 HARDWARE <br />A. EMERGENCY BREAKAWAY RELEASE SHALL ALLOW BOTH PANELS TO <br />SWING OUT 90 DEGREES <br />B. DEADLOCKS: 2-POINT LOCKING, KEY EXTERIOR, THUMB TURN <br />INTERIOR <br />C. CONTROL SWITCH: ROTARY SWITCH MOUNTED ON THE INTERIOR <br />JAMB <br />2.07 ALUMINUM FINISH <br />A. TO MATCH EXISTING STOREFRONT FINISH <br />PART 3 EXECUTION <br />3.01 INSPECTION <br />A. EXAMINE EXISTING CONDITIONS FOR COMPLIANCE WITH <br />REQUIREMENTS FOR INSTALLATION TOLERANCES, HEADER <br />SUPPORT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF <br />AUTOMATIC ENTRANCES. <br />3.02 INSTALLATION <br />A. DO NOT INSTALL DAMAGED COMPONENTS <br />B. INSTALL ENTRANCES PLUMB AND TRUE IN ALIGNMENT. ANCHOR <br />SECURELY IN PLACE. <br />C. DOOR OPERATORS: CONNECT DOOR OPERATORS TO ELECTRICAL <br />POWER DISTRIBUTION SYSTEM <br />D. GLAZING: PER MANUFACTURER'S INSTRUCTIONS <br />E. SEALANTS: PER DIVISION 7 SECTION JOINT SEALANTS <br />3.03 FIELD QUALITY CONTROL <br />A. TESTING SERVICES: FACTORY TRAINED INSTALLER SHALL TEST AND <br />INSPECT EACH DOOR FOR FULL COMPLIANCE. <br />3.04 ADJUSTING <br />A. ADJUST DOOR OPERATORS, CONTROLS, AND HARDWARE FOR <br />SMOOTH AND SAFE OPERATION. <br />3.05 CLEANING AND PROTECTION <br />A. CLEAN GLASS AND ALUMINUM SURFACES PROMPTLY AFTER <br />INSTALLATION. <br />END OF SECTION <br />SECTION 085113 - ALUMINUM WINDOWS <br />1.01 QUALITY ASSURANCE <br />A. MOCKUPS FOR EACH FORM OF CONSTRUCTION. <br />1.02 WARRANTY <br />A. WINDOWS: 10 YEARS FROM DATE OF SUBSTANTIAL COMPLETION. <br />B. GLAZING UNITS: 10 YEARS FROM DATE OF SUBSTANTIAL <br />COMPLETION. <br />C. ALUMINUM FINISH: 10 YEARS FROM DATE OF SUBSTANTIAL <br />COMPLETION. <br />1.03 WINDOW PERFORMANCE REQUIREMENTS <br />A. PRODUCT STANDARD: AAMA / WDMA / CSA 101 / I.S.2 / A440. <br />B. CONDENSATION -RESISTANCE FACTOR: 52 COMPLYING WITH <br />AAMA 1503. <br />C. SOUND TRANSMISSION CLASS: 26 MINIMUM. <br />1.04 ALUMINUM WINDOWS <br />A. FRAMES AND SASHES: NON -THERMAL ALUMINUM EXTRUSIONS. <br />B. GLAZING: <br />1. GLASS: CLEAR <br />C. GLAZING SYSTEM: MANUFACTURER'S STANDARD <br />D. ACCESSORIES: INTEGRAL VENTILATING SYSTEM/DEVICE <br />E. ALUMINUM FINISH: TO MATCH EXISTING STOREFRONT]. <br />1.05 FIELD QUALITY CONTROL <br />A. TESTING: BY CONTRACTOR -ENGAGED AGENCY. <br />END OF SECTION <br />SECTION 087100 - DOOR HARDWARE <br />PART1 GENERAL <br />1.01 SECTION INCLUDES <br />A. HARDWARE FOR HOLLOW STEEL AND WOOD DOORS. <br />B. LOCK CYLINDERS FOR DOORS FOR WHICH HARDWARE IS SPECIFIED <br />IN OTHER SECTIONS. <br />C. THRESHOLDS. <br />D. WEATHERSTRIPPING, SEALS AND'DOOR GASKETS. <br />1.02 REFERENCES <br />A. DHI (LOCS) - RECOMMENDED LOCATIONS FOR ARCHITECTURAL <br />HARDWARE FOR STANDARD STEEL DOORS AND FRAMES, DOOR AND <br />HARDWARE INSTITUTE, 2001. <br />B. NFPA 101 - CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND <br />STRUCTURES, NATIONAL FIRE PROTECTION ASSOCIATION, 2000. <br />1.03 QUALITY ASSURANCE <br />1.04 DELIVERY, STORAGE, AND PROTECTION <br />A. PACKAGE HARDWARE ITEMS INDIVIDUALLY, LABEL AND IDENTIFY <br />EACH PACKAGE WITH DOOR OPENING CODE TO MATCH HARDWARE <br />SCHEDULE. <br />1.05 COORDINATION <br />A. COORDINATE THE WORK WITH OTHER DIRECTLY AFFECTED <br />SECTIONS INVOLVING MANUFACTURE OR FABRICATION OF INTERNAL <br />REINFORCEMENT FOR DOOR HARDWARE. <br />B. FURNISH TEMPLATES FOR DOOR AND FRAME PREPARATION. <br />C. SEQUENCE INSTALLATION TO ENSURE UTILITY CONNECTIONS ARE <br />ACHIEVED IN AN ORDERLY AND EXPEDITIOUS MANNER. <br />D. COORDINATE THE OWNER'S KEYING REQUIREMENTS DURING THE <br />COURSE OF THE WORK. <br />1.06 WARRANTY <br />A. SEE SECTION 017700 -CLOSEOUT SUBMITTALS, FOR ADDITIONAL <br />WARRANTY REQUIREMENTS. <br />1.07 MAINTENANCE PRODUCTS <br />A. PROVIDE SPECIAL WRENCHES AND TOOLS APPLICABLE TO EACH <br />DIFFERENT OR SPECIAL HARDWARE COMPONENT. <br />B. PROVIDE MAINTENANCE TOOLS AND ACCESSORIES SUPPLIED BY <br />HARDWARE COMPONENT MANUFACTURER. <br />PART 2 PRODUCTS <br />2.01 REFER TO DRAWINGS FOR SCHEDULES AND SPECIFICATIONS. <br />2.02 GENERAL REQUIREMENTS FOR DOOR HARDWARE PRODUCTS <br />A. PROVIDE PRODUCTS THAT COMPLY WITH THE FOLLOWING: <br />1. APPLICABLE PROVISIONS OF FEDERAL, STATE, AND LOCAL <br />CODES. <br />2. APPLICABLE PROVISIONS OF NFPA 101, LIFE SAFETY CODE. <br />B. FINISHES: IDENTIFIED IN SCHEDULE. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. VERIFY THAT DOORS AND FRAMES ARE READY TO RECEIVE WORK <br />AND DIMENSIONS ARE AS INSTRUCTED BY THE MANUFACTURER. <br />3.02 INSTALLATION <br />A. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS AND APPLICABLE CODES. <br />B. USE TEMPLATES PROVIDED BY HARDWARE ITEM MANUFACTURER. <br />C. MOUNTING HEIGHTS FOR HARDWARE FROM FINISHED FLOOR TO <br />CENTER LINE OF HARDWARE ITEM: <br />1. FOR STEEL DOORS AND FRAMES: COMPLY WITH DHI <br />"RECOMMENDED LOCATIONS FOR ARCHITECTURAL HARDWARE <br />FOR STEEL DOORS AND FRAMES." <br />3.03 ADJUSTING <br />A. ADJUST WORK UNDER PROVISIONS OF SECTION 017700. <br />B. ADJUST HARDWARE FOR SMOOTH OPERATION. <br />3.04 PROTECTION OF FINISHED WORK <br />A. PROTECT FINISHED WORK UNDER PROVISIONS OF SECTION 017700. <br />B. DO NOT PERMIT ADJACENT WORK TO DAMAGE HARDWARE OR <br />FINISH. <br />END OF SECTION <br />SECTION 088000 - GLAZING <br />PART1 GENERAL <br />1.01 SECTION <br />INCLUDES <br />A. <br />GLASS AND PLASTIC GLAZING. <br />B. <br />GLAZING COMPOUNDS AND ACCESSORIES. <br />C. <br />MONOLITHIC CERAMIC ENAMEL FRIT SPANDREL GLASS, CERAMIC <br />ENAMEL FRIT SPANDREL GLASS IN INSULATING GLASS (IG) UNITS <br />1.02 RELATED SECTIONS <br />A. <br />SECTION 079200 - JOINT SEALERS: SEALANT AND BACK-UP <br />MATERIAL. <br />B. <br />SECTION 081113 - HOLLOW METAL DOORS AND FRAMES: GLAZED <br />DOORS AND BORROWED LITES. <br />C. <br />SECTION 084113 - ALUMINUM -FRAMED STOREFRONTS. <br />1.03 REFERENCES <br />A. <br />ANSI Z97.1 - AMERICAN NATIONAL STANDARD FOR SAFETY GLAZING <br />MATERIALS USED IN BUILDINGS, SAFETY PERFORMANCE <br />SPECIFICATIONS AND METHODS OF TEST, 1984 (R1994). <br />B. <br />ASTM C162 - STANDARD TERMINOLOGY OF GLASS AND GLASS <br />PRODUCTS. <br />C. <br />ASTM C 1036 - STANDARD SPECIFICATION FOR FLAT GLASS, 2001. <br />D. <br />ASTM C1048 - STANDARD SPECIFICATION FOR HEAT -TREATED FLAT <br />GLASS - KIND HS, KIND FT COATED AND UNCOATED GLASS. <br />E. <br />ASTM C 1193 - STANDARD GUIDE FOR USE OF JOINT SEALANTS, 2000. <br />F. <br />ASTM E2188 - STANDARD TEST METHOD FOR INSULATING GLASS <br />UNIT PERFORMANCE. <br />G. <br />ASTM E2189 - STANDARD TEST METHOD FOR TESTING RESISTANCE <br />TO FOGGING IN INSULATING GLASS UNITS. <br />H. <br />ASTM E2190 - STANDARD SPECIFICATION FOR INSULATING GLASS <br />UNIT PERFORMANCE AND EVALUATION. <br />I. <br />ASTM E1300 - STANDARD PRACTICE FOR DETERMINING THE MINIMUM <br />THICKNESS AND TYPE OF GLASS REQUIRED TO RESIST A SPECIFIED <br />LOAD. <br />J. <br />ASTM E2188 - STANDARD TEST METHOD FOR INSULATING GLASS <br />UNIT PERFORMANCE. <br />K. <br />ASTM E2189 - STANDARD TEST METHOD FOR TESTING RESISTANCE <br />TO FOGGING IN INSULATING GLASS UNITS. <br />L. <br />ASTM E2190 - STANDARD SPECIFICATION FOR INSULATING GLASS <br />UNIT PERFORMANCE AND EVALUATION. <br />M. <br />GANA (GM) - GANA GLAZING MANUAL, GLASS ASSOCIATION OF <br />NORTH AMERICA, 1997. <br />N. <br />GANA (SM) - FGMA SEALANT MANUAL, GLASS ASSOCIATION OF <br />NORTH AMERICA, 1990. <br />1.04 QUALITY ASSURANCE <br />A. <br />PERFORM WORK IN ACCORDANCE WITH GANA GLAZING MANUAL <br />AND FGMA SEALANT MANUAL FOR GLAZING INSTALLATION METHODS. <br />B. <br />INSTALLER QUALIFICATIONS: COMPANY SPECIALIZING IN <br />PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 5 YEARS <br />DOCUMENTED EXPERIENCE. <br />C. <br />SAFETY GLASS PRODUCTS IN THE US ARE TO COMPLY WITH CPSC 16 <br />CFR PART 1201 FOR CATEGORY II MATERIALS. <br />D. <br />INSULATING GLASS PRODUCTS ARE TO BE PERMANENTLY MARKED <br />EITHER ON SPACERS OR AT LEAST ONE INSULATING UNIT <br />COMPONENT WITH APPROPRIATE CERTIFICATION LABEL OF <br />INSPECTING AND TESTING AGENCY INDICATED BELOW: <br />1. US - INSULATING GLASS CERTIFICATION COUNCIL (IGCC) <br />1.05 ENVIRONMENTAL REQUIREMENTS <br />A. <br />DO NOT INSTALL GLAZING WHEN AMBIENT TEMPERATURE IS LESS <br />THAN 50 DEGREES F (10 DEGREES C). <br />B. <br />MAINTAIN MINIMUM AMBIENT TEMPERATURE BEFORE, DURING AND <br />24 HOURS AFTER INSTALLATION OF GLAZING COMPOUNDS. <br />1.06 WARRANTY <br />A. <br />SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL <br />WARRANTY REQUIREMENTS. <br />B. <br />PROVIDE A FIVE (5) YEAR WARRANTY TO INCLUDE COVERAGE FOR <br />SEALED GLASS UNITS FROM SEAL FAILURE, INTERPANE DUSTING OR <br />MISTING, AND REPLACEMENT OF SAME. <br />PART 2 PRODUCTS <br />2.01 FLAT GLASS MATERIALS <br />A. <br />MANUFACTURERS: <br />1. AFG INDUSTRIES, INC: WWW.AFGGLASS.COM. <br />2. GUARDIAN INDUSTRIES CORPORATION: WWW.GUARDIAN.COM. <br />3. PPG INDUSTRIES, INC: WWW.PPG.COM. <br />4. OLDCASTLE BUILDINGENVELOPEO <br />5. SUBSTITUTIONS: REFER TO SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />B. <br />CLEAR FLOAT GLASS: CLEAR, HEAT STRENGTHENED. <br />1. COMPLY WITH ASTM C 1048, TYPE I, TRANSPARENT FLAT, <br />CLASS 1 CLEAR, QUALITY Q3 (GLAZING SELECT). <br />C. <br />SAFETY GLASS: CLEAR, FULLY TEMPERED WITH HORIZONTAL <br />TEMPERING. <br />1. COMPLY WITH ANSI Z97.1. <br />2.02 SEALED INSULATING GLASS MATERIALS <br />A. <br />MANUFACTURERS: <br />1. GUARDIAN INDUSTRIES CORPORATION: WWW.GUARDIAN.COM. <br />2. PPG INDUSTRIES, INC. WWW.PPGGLAZING.COM <br />3. SUBSTITUTIONS: REFER TO SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />B. <br />INSULATED GLASS UNITS: DOUBLE PANE WITH GLASS TO <br />ELASTOMER EDGE SEAL. <br />1. OUTER PANE OF FLOAT GLASS, INNER PANE OF FLOAT GLASS. <br />2. TOTAL UNIT THICKNESS OF 1 INCH. <br />3. PROVIDE SAFETY GLASS AS INDICATED. <br />C. <br />EDGE SEAL CONSTRUCTION: ALUMINUM, BENT AND SOLDERED <br />CORNERS. <br />D. <br />EDGE SEAL MATERIAL: BLACK COLOR. <br />2.03 SEALED INSULATING GLASS (IG) UNITS WITH CERAMIC ENAMEL FRIT <br />SPANDREL INBOARD LITE <br />1. INSULATING GLASS UNIT MAKEUP <br />2. GLASS TINT: TO BE SELECTED <br />3. NOMINAL THICKNESS: TO MATCH EXISTING <br />2.04 GLAZING ACCESSORIES <br />A. <br />PRODUCTS IN COMPLIANCE WITH ASTM C920 AND REFERENCED <br />GLAZING STANDARDS, THE REQUIREMENTS OF THE GLASS AND <br />STOREFRONT MANUFACTURERS AND PROVEN TRACK RECORD TO <br />BE COMPATABLE WITH ONE ANOTHER AND WITH THE MATERIALS <br />THEY WILL COME IN CONTACT WITH. <br />1. COMPRESSION GASKETS: AS REQUIRED FOR SPECIFED <br />ALUMINIUM STOREFRONT AND DOOR SYSTEMS. <br />2. SUBSTITUTIONS: REFER TO SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />VERIFY THAT OPENINGS FOR GLAZING ARE CORRECTLY SIZED AND <br />WITHIN TOLERANCE. <br />B. <br />VERIFY THAT SURFACES OF GLAZING CHANNELS OR RECESSES ARE <br />CLEAN, FREE OF OBSTRUCTIONS THAT MAY IMPEDE MOISTURE <br />MOVEMENT, WEEPS ARE CLEAR, AND READY TO RECEIVE GLAZING. <br />3.02 PREPARATION <br />A. <br />CLEAN CONTACT SURFACES WITH SOLVENT AND WIPE DRY. <br />B. <br />SEAL POROUS GLAZING CHANNELS OR RECESSES WITH SUBSTRATE <br />COMPATIBLE PRIMER OR SEALER. <br />C. <br />PRIME SURFACES SCHEDULED TO RECEIVE SEALANT. <br />D. <br />INSTALL SEALANTS IN ACCORDANCE WITH ASTM C 1193 AND FGMA <br />SEALANT MANUAL. <br />E. <br />INSTALL SEALANT IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />F. <br />PROTECT GLASS EDGES DURING HANDLING AND INSTALLATION. <br />G. <br />DO NOTEXCEED EDGE PRESSURES SPECIFIED BY GLASS <br />MANUFACTURER FOR INSTALLING GLASS LITES. <br />H. <br />SET GLASS LITES IN SERIES WITH UNIFORM DRAW, BOW AND <br />SIMILAR CHARACTERISTICS. <br />I. <br />COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR <br />GLASS, SEALANTS, GASKETS AND OTHER GLAZING MATERIALS. <br />3.03 CLEANING <br />A. <br />REMOVE GLAZING MATERIALS FROM FINISH SURFACES. <br />B. <br />REMOVE LABELS AFTER WORK IS COMPLETE. <br />C. <br />CLEAN GLASS AND ADJACENT SURFACES. <br />3.04 PROTECTION OF FINISHED WORK <br />A. <br />AFTER INSTALLATION, MARK PANE WITH AN 'X' BY USING REMOVABLE <br />PLASTIC TAPE OR PASTE. <br />END OF SECTION <br />SECTION 088720 - ARCHITECTURAL WINDOW FILM <br />PART1 GENERAL <br />1.01 SECTION INCLUDES <br />A. INTERIOR WINDOW FILM <br />B. DECORATIVE WINDOW FILM. <br />C. PRIVACY WINDOW FILM. <br />1.02 PERFORMANCE REQUIREMENTS <br />A. <br />FIRE PERFORMANCE: SURFACE BURNING CHARACTERISTICS WHEN <br />TESTED IN ACCORDANCE WITH ASTM E 84: <br />1. FLAME SPREAD: 25, MAXIMUM <br />2. SMOKE DEVELOPED: 450, MAXIMUM. <br />1.05 PROJECT CONDITIONS <br />A. <br />MAINTAIN ENVIRONMENTAL CONDITIONS (TEMPERATURE, HUMIDITY, <br />AND VENTILATION) WITHIN LIMITS RECOMMENDED BY <br />MANUFACTURER FOR OPTIMUM RESULTS. DO NOT INSTALL <br />PRODUCTS UNDER ENVIRONMENTAL CONDITIONS OUTSIDE <br />MANUFACTURER'S ABSOLUTE LIMITS. <br />PART 2 PRODUCTS <br />2.01 WINDOW FILM <br />A. <br />MANUFACTURERS: <br />1. 3M <br />2. HANITA TEK WINDOW FILMS <br />B. <br />COLOR: FROSTED. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />DO NOT BEGIN INSULATION UNTIL SUBSTRATES HAVE BEEN <br />PROPERLY PREPARED. <br />3.02 PREPARATION <br />A. <br />CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION. <br />B. <br />PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE <br />MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR THE <br />SUBSTRATE UNDER THE PROJECT CONDITIONS. <br />3.04 INSULATION <br />A. <br />INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />B. <br />CUT FILM EDGES NEATLY AND SQUARE AT A UNIFORM DISTANCE OF <br />1/8 INCH (3 MM) TO 1/16 INCH (1.5 MM) OF WINDOW SEALANT. USE <br />NEW BLADE TIPS AFTER 3 TO 4 CUTS. <br />C. <br />SPRAY THE SLIP SOLUTION, COMPOSED OF ONE CAPFUL OF BABY <br />SHAMPOO OR DISHWASHING LIQUID TO 1 GALLON OF WATER, ON <br />WINDOW GLASS AND ADHESIVE TO FACILITATE PROPER <br />POSITIONING OF FILM. <br />D. <br />APPLY FILM TO GLASS AND LIGHTLY SPRAY FILM WITH SLIP <br />SOLUTION. <br />E. <br />SQUEEGEE FROM TOP TO BOTTOM OF WINDOW. SPRAY SLIP <br />SOLUTION TO FILM AND SQUEEGEE A SECOND TIME. <br />F. <br />BUMP FILM EDGE WITH LINT -FREE TOWEL WRAPPED AROUND EDGE <br />OF A 5-WAY TOOL. <br />G. <br />UPON COMPLETION OF FILM APPLICATION, ALLOW 30 DAYS FOR <br />MOISTURE FROM FILM INSTALLATION TO DRY THOROUGHLY, AND TO <br />ALLOW FILM TO DRY FLAT WITH NO MOISTURE DIMPLES WHEN <br />VIEWED UNDER NORMAL VIEWING CONDITIONS <br />3.05 CLEAN AND PROTECTION <br />A. <br />REMOVE LEFT OVER MATERIAL AND DEBRIS FROM WORK AREA. USE <br />NECESSARY MEANS TO PROTECT FILM BEFORE, DURING, AND AFTER <br />INSTALLATION. <br />B. <br />TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE <br />SUBSTANTIAL COMPLETION. <br />C. <br />AFTER APPLICATION OF FILM, WASH FILM USING COMMON WINDOW <br />CLEANING SOLUTIONS, INCLUDING AMMONIA SOLUTIONS, 30 DAYS <br />AFTER APPLICATION. DO NOT USE ABRASIVE TYPE CLEANING <br />AGENTS AND BRISTLE BRUSHES TO AVOID SCRATCHING FILM. USE <br />SYNTHETIC SPONGES OR SOFT CLOTHS. <br />END OF SECTION <br />SECTION 092900 - GYPSUM BOARD ASSEMBLIES <br />PART1 GENERAL <br />1.01 SECTION <br />INCLUDES <br />A. <br />METAL STUD WALL FRAMING. <br />B. <br />METAL CHANNEL CEILING FRAMING. <br />C. <br />ACOUSTIC INSULATION. <br />D. <br />GYPSUM SHEATHING. <br />E. <br />GYPSUM WALLBOARD. <br />F. <br />JOINT TREATMENT AND ACCESSORIES. <br />1.02 REFERENCES <br />A. <br />ASTM C 36/C 36M - STANDARD SPECIFICATION FOR GYPSUM <br />WALLBOARD, 2001. <br />B. <br />ASTM C 79/C 79M - STANDARD SPECIFICATION FOR TREATED CORE <br />AND NONTREATED CORE GYPSUM SHEATHING BOARD, 2001. <br />C. <br />ASTM C 475/C 475M - STANDARD SPECIFICATION FOR JOINT <br />COMPOUND AND JOINT TAPE FOR FINISHING GYPSUM BOARD, 2002. <br />D. <br />ASTM C 630/C 630M - STANDARD SPECIFICATION FOR <br />WATER-RESISTANT GYPSUM BACKING BOARD, 2000. <br />E. <br />ASTM C 645 - STANDARD SPECIFICATION FOR NONSTRUCTURAL <br />STEEL FRAMING MEMBERS, 2000. <br />F. <br />ASTM C 665 - STANDARD SPECIFICATION FOR MINERAL -FIBER <br />BLANKET THERMAL INSULATION FOR LIGHT FRAME CONSTRUCTION <br />AND MANUFACTURED HOUSING, 2001. <br />G. <br />ASTM C 754 - STANDARD SPECIFICATION FOR INSTALLATION OF <br />STEEL FRAMING MEMBERS TO RECEIVE SCREW -ATTACHED GYPSUM <br />PANEL PRODUCTS, 2000. <br />H. <br />ASTM C 840 - STANDARD SPECIFICATION FOR APPLICATION AND <br />FINISHING OF GYPSUM BOARD, 2002. <br />I. <br />ASTM C 1002 - STANDARD SPECIFICATION FOR STEEL SELF -PIERCING <br />TAPPING SCREWS FOR THE APPLICATION OF GYPSUM PANEL <br />PRODUCTS OR METAL PLASTER BASES TO WOOD STUDS OR STEEL <br />STUDS, 2001. <br />1.03 QUALITY ASSURANCE <br />A. <br />PERFORM IN ACCORDANCE WITH ASTM C 840. <br />PART 2 PRODUCTS <br />2.01 METAL FRAMING MATERIALS <br />A. <br />NON-LOADBEARING FRAMING SYSTEM COMPONENTS: ASTM C 645, <br />GALVANIZED SHEET STEEL, OF SIZE AND PROPERTIES NECESSARY <br />TO COMPLY WITH ASTM C 754 FOR THE SPACING INDICATED, WITH <br />MAXIMUM DEFLECTION OF WALL FRAMING OF U240 AT 5 PSF (240 PA). <br />1. STUDS: C SHAPED WITH KNURLED FACES. <br />2. RUNNERS: U SHAPED, SIZED TO MATCH STUDS. <br />3. CEILING CHANNELS: C SHAPED. <br />B. <br />CEILING HANGERS: TYPE AND SIZE AS SPECIFIED IN ASTM C 754 FOR <br />SPACING REQUIRED. <br />C. <br />PARTITION HEAD TO STRUCTURE CONNECTIONS: PROVIDE TRACK <br />FASTENED TO STRUCTURE WITH LEGS OF SUFFICIENT LENGTH TO <br />ACCOMMODATE DEFLECTION, FOR FRICTION FIT OF STUDS CUT <br />SHORT AND FASTENED AS INDICATED ON DRAWINGS. <br />D. <br />BOTTOM AND TOP TRACK OF CURVED CURTAIN WALL TO BE <br />CONSTRUCTED WITH 3 5/8"'FLEXTRACK' OR EQUAL. SOURCE: FIVE <br />STAR SUPPLY (216) 595-9525 <br />2.02 GYPSUM BOARD MATERIALS <br />A. <br />GYPSUM WALLBOARD: ASTM C 36/C 36M AND ASTM C 1396/C 1396M. <br />SIZES TO MINIMIZE JOINTS IN PLACE, ENDS SQUARE CUT. <br />1. EDGES: TAPERED. <br />B. <br />WATER-RESISTANT GYPSUM BACKING BOARD: ASTM C 630/C 630M <br />AND ASTM C 1396/C 1396M, ENDS SQUARE CUT. <br />C. <br />EXTERIOR GYPSUM SHEATHING BOARD: GYPSUM SHEATHING <br />MANUFACTURED IN ACCORDANCE WITH ASTM C 1177 WITH GLASS <br />MATS BOTH SIDES AND LONG EDGES, WATER-RESISTANT TREATED <br />CORE.. <br />1. EDGES: SQUARE, FOR VERTICAL APPLICATION. <br />2.03 ACCESSORIES <br />A. <br />ACOUSTIC INSULATION: ASTM C 665, PREFORMED GLASS FIBER, <br />FRICTION FIT TYPE, UNFACED. <br />B. <br />JOINT MATERIALS: ASTM C 475 AND AS RECOMMENDED BY GYPSUM <br />BOARD MANUFACTURER FOR PROJECT CONDITIONS. <br />1. POWDER -TYPE VINYL -BASED JOINT COMPOUND. <br />C. <br />SCREWS: ASTM C 1002, SELF -PIERCING TAPPING TYPE. <br />D. <br />STAPLES: ASTM C 840. <br />E. <br />ANCHORAGE TO SUBSTRATE: TIE WIRE, NAILS, SCREWS, AND <br />OTHER METAL SUPPORTS, OF TYPE AND SIZE TO SUIT APPLICATION, <br />TO RIGIDLY SECURE MATERIALS IN PLACE. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />VERIFY THAT PROJECT CONDITIONS ARE APPROPRIATE FOR WORK <br />OF THIS SECTION TO COMMENCE. <br />3.02 FRAMING <br />INSTALLATION <br />A. <br />METAL FRAMING: COMPLY WITH ASTM C 754 AND MANUFACTURER'S <br />INSTRUCTIONS. <br />B. <br />SUSPENDED CEILINGS AND SOFFITS: SPACE FRAMING AND FURRING <br />MEMBERS AT 16 INCHES (400 MM) ON CENTER. <br />1. LEVEL CEILING SYSTEM TO A TOLERANCE OF 1/1200. <br />2. LATERALLY BRACE ENTIRE SUSPENSION SYSTEM. <br />3. INSTALL BRACING AS REQUIRED AT ENTRY VESTIBULE TO <br />RESIST WIND UPLIFT. <br />C. <br />STUDS: SPACE STUDS AS INDICATED. <br />1. EXTEND PARTITION FRAMING TO STRUCTURE AND TO OTHER <br />LOCATIONS AS INDICATED ON THE DRAWINGS. <br />2. PARTITIONS TERMINATING AT STRUCTURE: ATTACH <br />EXTENDED LEG TOP RUNNER TO STRUCTURE, MAINTAIN <br />CLEARANCE BETWEEN TOP OF STUDS AND STRUCTURE, AND <br />BRACE BOTH FLANGES OF STUDS WITH CONTINUOUS <br />BRIDGING. <br />3. SPACE STUD FRAMING AT RADIUS WALL TO PROVIDE UNIFORM <br />GYPSUM BOARD FINISH. <br />4. SPACE STUDS & FRAMING TO ACCOMODATE THROUGH WALL <br />AND RECESS EQUIPMENT IN WALL. <br />D. <br />OPENINGS: REINFORCE OPENINGS AS REQUIRED FOR WEIGHT OF <br />DOORS OR OPERABLE PANELS, USING NOT LESS THAN DOUBLE <br />STUDS AT JAMBS. <br />E. <br />BLOCKING: INSTALL BLOCKING FOR SUPPORT OF PLUMBING <br />FIXTURES, FIXTURES AND EQUIPMENT. COMPLY WITH SECTION <br />061000 FOR WOOD BLOCKING. <br />3.03 ACOUSTIC <br />ACCESSORIES INSTALLATION <br />A. <br />ACOUSTIC INSULATION: PLACE TIGHTLY WITHIN SPACES, AROUND <br />CUT OPENINGS, BEHIND AND AROUND ELECTRICAL AND <br />MECHANICAL ITEMS WITHIN PARTITIONS, AND TIGHT TO ITEMS <br />PASSING THROUGH PARTITIONS. <br />3.04 GYPSUM BOARD INSTALLATION <br />A. <br />COMPLY WITH ASTM C 840 AND MANUFACTURER'S INSTRUCTIONS. <br />INSTALL TO MINIMIZE BUTT END JOINTS, ESPECIALLY IN HIGHLY <br />VISIBLE LOCATIONS. <br />B. <br />SINGLE -LAYER NON -RATED: INSTALL GYPSUM BOARD IN MOST <br />ECONOMICAL DIRECTION, WITH ENDS AND EDGES OCCURRING OVER <br />FIRM BEARING. <br />C. <br />GYPSUM SHEATHING: COMPLY WITH GA-253. INSTALL SHEATHING <br />HORIZONTALLY, WITH EDGES BUTTED TIGHT AND ENDS OCCURRING <br />OVER FIRM BEARING. <br />D. <br />INSTALLATION ON METAL FRAMING: USE SCREWS FOR ATTACHMENT <br />OF ALL GYPSUM BOARD. <br />3.05 INSTALLATION OF TRIM AND ACCESSORIES <br />A. <br />CONTROL JOINTS: PLACE CONTROL JOINTS CONSISTENT WITH LINES <br />OF BUILDING SPACES. <br />B. <br />CORNER BEADS: INSTALL AT EXTERNAL CORNERS, USING LONGEST <br />PRACTICAL LENGTHS. <br />3.06 JOINT <br />TREATMENT <br />A. <br />FINISH GYPSUM BOARD IN ACCORDANCE WITH ASTM C 840. LEVEL 4 <br />FINISH AT WALLS AND CEILINGS EXCEPT FOR LEVEL 4 FINISH AT <br />CEILING LOCATIONS INDICATED ON PLANS AND LEVEL 1 ABOVE <br />CEILINGS. <br />3.07 TOLERANCES <br />A. <br />MAXIMUM VARIATION OF FINISHED GYPSUM BOARD SURFACE FROM <br />TRUE FLATNESS: 1/8 INCH IN 10 FEET (3 MM IN 3 M) IN ANY <br />DIRECTION. <br />3.08 FINISH LEVEL SCHEDULE <br />A. <br />LEVEL 1: ABOVE FINISHED CEILINGS CONCEALED FROM VIEW. <br />B. <br />LEVEL 4: WALLS AND CEILINGS SCHEDULED TO RECEIVE PAINT <br />FINISH. <br />END OF SECTION <br />Z <br />O <br />H <br />d <br />U <br />W <br />W <br />0 <br />uw <br />4,11011. OF <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />JOB NO. <br />18390 <br />AS1 05 <br />