SECTION 093000 -TILING
<br />PART 1 - GENERAL
<br />1.1 SUMMARY
<br />A.
<br />THIS SECTION INCLUDES THE FOLLOWING:
<br />1. GLAZED WALL TILE.
<br />2. QUARRY TILE AND BASE.
<br />3. METAL EDGE STRIPS INSTALLED AS PART OF TILE
<br />INSTALLATIONS.
<br />1.2 EXTRA MATERIALS
<br />A.
<br />FURNISH EXTRA MATERIALS DESCRIBED BELOW THAT MATCH
<br />PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE
<br />COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING
<br />CONTENTS.
<br />1. TILE AND TRIM UNITS: FURNISH QUANTITY OF FULL-SIZE UNITS
<br />EQUAL TO 3 PERCENT OF AMOUNT INSTALLED, FOR EACH
<br />TYPE, COMPOSITION, COLOR, PATTERN, AND SIZE INDICATED.
<br />PART 2 - PRODUCTS
<br />2.1 MANUFACTURERS
<br />A.
<br />PROVIDE PRODUCTS FROM MANUFACTURERS AS SCHEDULED ON
<br />DRAWINGS.
<br />2.2 TILE
<br />PRODUCTS
<br />A.
<br />MANUFACTURERS: AS SCHEDULED ON DRAWINGS.
<br />B.
<br />PROVIDE TRIM PIECES, BULLNOSE TILE, COVED BASEINSIDE AND
<br />OUTSIDE CORNERS NECESSARY FOR PROJECT INSTALLATION.
<br />2.3 SETTING AND GROUTING MATERIALS
<br />A.
<br />AVAILABLE MANUFACTURERS: REFER TO FINISH SCHEDULE.
<br />B.
<br />LATEX-PORTLAND CEMENT MORTAR (THIN SET): ANSI A118.4.
<br />1. PREPACKAGED DRY -MORTAR MIX COMBINED WITH
<br />LIQUID -LATEX ADDITIVE.
<br />2. FOR WALL APPLICATIONS, PROVIDE NONSAGGING MORTAR.
<br />C.
<br />POLYMER -MODIFIED TILE GROUT: ANSI A118.7, COLOR AS INDICATED.
<br />2.4 MISCELLANEOUS MATERIALS
<br />A.
<br />TRANSITION AND EDGE TRIMS. PROVIDE SCHLUTER TRIMS AS
<br />INDICATED ON DRAWINGS.
<br />PART 3 - EXECUTION
<br />3.1 PREPARATION
<br />A.
<br />REMOVE COATINGS, INCLUDING CURING COMPOUNDS AND OTHER
<br />SUBSTANCES THAT CONTAIN SOAP, WAX, OIL, OR SILICONE, THAT ARE
<br />INCOMPATIBLE WITH TILE -SETTING MATERIALS.
<br />B.
<br />FILL CRACKS, HOLES, AND DEPRESSIONS WITH TROWELABLE
<br />LEVELING AND PATCHING COMPOUND ACCORDING TO TILE -SETTING
<br />MATERIAL MANUFACTURER'S WRITTEN INSTRUCTIONS.
<br />C.
<br />REMOVE PROTRUSIONS, BUMPS, AND RIDGES BY SANDING OR
<br />GRINDING.
<br />D.
<br />BLENDING: FOR TILE EXHIBITING COLOR VARIATIONS, USE FACTORY
<br />BLENDED TILE OR BLEND TILES AT PROJECT SITE BEFORE
<br />INSTALLING.
<br />E.
<br />FIELD -APPLIED TEMPORARY PROTECTIVE COATING: WHERE
<br />INDICATED UNDER TILE TYPE OR NEEDED TO PREVENT GROUT FROM
<br />STAINING OR ADHERING TO EXPOSED TILE SURFACES, PRECOAT
<br />THEM WITH CONTINUOUS FILM OF TEMPORARY PROTECTIVE COATING,
<br />TAKING CARE NOT TO COAT UNEXPOSED TILE SURFACES.
<br />3.2 INSTALLATION, GENERAL
<br />A.
<br />ANSI TILE INSTALLATION STANDARDS: COMPLY WITH PARTS OF ANSI
<br />A108 SERIES "SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE"
<br />THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND
<br />TO METHODS INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES.
<br />B.
<br />TCA INSTALLATION GUIDELINES: TCA'S "HANDBOOK FOR CERAMIC
<br />TILE INSTALLATION." COMPLY WITH TCA INSTALLATION METHODS
<br />INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES.
<br />C.
<br />EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND
<br />EQUIPMENT AND FIXTURES TO FORM COMPLETE COVERING WITHOUT
<br />INTERRUPTIONS, UNLESS OTHERWISE INDICATED. TERMINATE WORK
<br />NEATLY AT OBSTRUCTIONS, EDGES, AND CORNERS WITHOUT
<br />DISRUPTING PATTERN OR JOINT ALIGNMENTS.
<br />D.
<br />ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM
<br />CUTTING AND DRILLING OF TILE WITHOUT MARRING VISIBLE
<br />SURFACES. GRIND CUT EDGES OF TILE ABUTTING TRIM, FINISH, OR
<br />BUILT-IN ITEMS. FIT TILE CLOSELY TO ELECTRICAL OUTLETS, PIPING,
<br />FIXTURES, AND OTHER PENETRATIONS SO PLATES, COLLARS, OR
<br />COVERS OVERLAP TILE.
<br />E.
<br />JOINTING PATTERN: LAY TILE IN GRID PATTERN, UNLESS OTHERWISE
<br />INDICATED. ALIGN JOINTS WHEN ADJOINING TILES ON FLOOR, BASE,
<br />WALLS, AND TRIM ARE SAME SIZE. LAY OUT TILE WORK AND CENTER
<br />TILE FIELDS IN BOTH DIRECTIONS IN EACH SPACE OR ON EACH WALL
<br />AREA. ADJUST TO MINIMIZE TILE CUTTING. PROVIDE UNIFORM JOINT
<br />WIDTHS, UNLESS OTHERWISE INDICATED.
<br />F.
<br />LAY OUT TILE WAINSCOTS TO NEXT FULL TILE BEYOND DIMENSIONS
<br />INDICATED.
<br />G.
<br />EXPANSION JOINTS: LOCATE EXPANSION JOINTS AND OTHER
<br />SEALANT -FILLED JOINTS DURING INSTALLATION OF SETTING
<br />MATERIALS, MORTAR BEDS, AND TILE. DO NOT SAW -CUT JOINTS
<br />AFTER INSTALLING TILES.
<br />1. LOCATE JOINTS IN TILE SURFACES DIRECTLY ABOVE JOINTS IN
<br />CONCRETE SUBSTRATES.
<br />2. PREPARE JOINTS AND APPLY SEALANTS TO COMPLY WITH
<br />REQUIREMENTS IN DIVISION 07 SECTION "JOINT SEALANTS."
<br />H.
<br />FOR INSTALLATIONS INDICATED BELOW, FOLLOW PROCEDURES IN
<br />ANSI A108 SERIES TILE INSTALLATION STANDARDS FOR PROVIDING 95
<br />PERCENT MORTAR COVERAGE.
<br />1. TILE FLOORS IN WET AREAS.
<br />2. TILE FLOORS COMPOSED OF TILES 8 BY 8 INCHES (200 BY 200
<br />MM) OR LARGER.
<br />3. TILE FLOORS COMPOSED OF RIB -BACKED TILES.
<br />1.
<br />INSTALL TILE ON FLOORS WITH THE FOLLOWING JOINT WIDTHS:
<br />1. PORCELAIN CERAMIC: 1/4 INCH (6.35 MM).
<br />2. QUARRY TILE: 318 INCH (6.35 MM).
<br />K.
<br />METAL EDGE STRIPS: INSTALL AT LOCATIONS INDICATED OR WHERE
<br />EXPOSED EDGE OF TILE FLOORING MEETS CARPET, WOOD, OR OTHER
<br />FLOORING THAT FINISHES FLUSH WITH TOP OF TILE.
<br />L.
<br />INSTALL TILE ON WALLS WITH THE FOLLOWING JOINT WIDTHS:
<br />1. GLAZED WALL TILE: 1/16 INCH (1.6 MM).
<br />3.3 WALL TILE INSTALLATION SCHEDULE
<br />A.
<br />INTERIOR WALL INSTALLATION, THIN -SET MORTAR, OVER GYPSUM
<br />BOARD, TCA W243.
<br />1. THIN -SET MORTAR: LAYTEX-PORTLAND CEMENT MORTAR.
<br />2. GROUT: POLYMER -MODIFIED SANDED GROUT.
<br />END OF SECTION
<br />SECTION 095113 - ACOUSTICAL PANEL CEILINGS
<br />PART 1 GENERAL
<br />1.01 SECTION INCLUDES
<br />A. SUSPENDED METAL GRID CEILING SYSTEM.
<br />B. ACOUSTICAL UNITS.
<br />1.02 REFERENCES
<br />A. ASTM C 635 - STANDARD SPECIFICATION FOR THE MANUFACTURE,
<br />PERFORMANCE, AND TESTING OF METAL SUSPENSION SYSTEMS FOR
<br />ACOUSTICAL TILE AND LAY -IN PANEL CEILINGS, 2000.
<br />B. ASTM C 636 - STANDARD PRACTICE FOR INSTALLATION OF METAL
<br />CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY -IN
<br />PANELS, 1996.
<br />C. ASTM E 1264 - STANDARD CLASSIFICATION FOR ACOUSTICAL CEILING
<br />PRODUCTS, 1998.
<br />D. LATEST EDITION OF CISCA - GUIDELINES FOR SEISMIC RESTRAINT FOR
<br />DIRECT HUNG SUSPENDED CEILING ASSEMBLIES.
<br />1.03 QUALITY ASSURANCE
<br />A. ACOUSTICAL UNIT MANUFACTURER QUALIFICATIONS: COMPANY
<br />SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS
<br />SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE.
<br />1.04 ENVIRONMENTAL REQUIREMENTS
<br />A. MAINTAIN UNIFORM TEMPERATURE OF MINIMUM 60 DEGREES F (16
<br />DEGREES C), AND MAXIMUM HUMIDITY OF 40 PERCENT PRIOR TO,
<br />DURING, AND AFTER ACOUSTICAL UNIT INSTALLATION.
<br />1.05 PROJECT CONDITIONS
<br />A. SEQUENCE WORK TO ENSURE ACOUSTICAL CEILINGS ARE NOT
<br />INSTALLED UNTIL BUILDING IS ENCLOSED, SUFFICIENT HEAT IS
<br />PROVIDED, DUST GENERATING ACTIVITIES HAVE TERMINATED, AND
<br />OVERHEAD WORK IS COMPLETED, TESTED, AND APPROVED.
<br />B. INSTALL ACOUSTICAL UNITS AFTER INTERIOR WET WORK IS DRY.
<br />PART 2 PRODUCTS
<br />2.01 ACOUSTICAL UNITS
<br />A. REFER TO DRAWING SCHEDULE.
<br />2.02 SUSPENSION SYSTEM(S)
<br />A. MANUFACTURERS:
<br />1. REFER TO FINISH SCHEDULE.
<br />2. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT
<br />REQUIREMENTS.
<br />B. SUSPENSION SYSTEMS - GENERAL: ASTM C 635, DIE CUT AND
<br />INTERLOCKING COMPONENTS, WITH STABILIZER BARS, CLIPS,
<br />SPLICES, PERIMETER MOLDINGS, AND HOLD DOWN CLIPS AS
<br />REQUIRED.
<br />2.03 ACCESSORIES
<br />A. SUPPORT CHANNELS AND HANGERS: GALVANIZED STEEL, SIZE AND
<br />TYPE TO SUIT APPLICATION AND CEILING SYSTEM FLATNESS
<br />REQUIREMENT SPECIFIED.
<br />B. PERIMETER MOLDINGS: SAME MATERIAL AND FINISH AS GRID.
<br />C. TOUCH-UP PAINT: TYPE AND COLOR TO MATCH ACOUSTICAL AND
<br />GRID UNITS.
<br />PART 3 EXECUTION
<br />3.01 EXAMINATION
<br />A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK.
<br />B. VERIFY THAT LAYOUT OF HANGERS WILL NOT INTERFERE WITH
<br />OTHER WORK.
<br />3.02 INSTALLATION - SUSPENSION SYSTEM
<br />A. INSTALL SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C 636 AND
<br />MANUFACTURER'S INSTRUCTIONS AND AS SUPPLEMENTED IN THIS
<br />SECTION.
<br />B. RIGIDLY SECURE SYSTEM, INCLUDING INTEGRAL MECHANICAL AND
<br />ELECTRICAL COMPONENTS, FOR MAXIMUM DEFLECTION OF 1:360.
<br />C. INSTALL AFTER MAJOR ABOVE -CEILING WORK IS COMPLETE.
<br />COORDINATE THE LOCATION OF HANGERS WITH OTHER WORK.
<br />D. HANG SUSPENSION SYSTEM INDEPENDENT OF WALLS, COLUMNS,
<br />DUCTS, PIPES AND CONDUIT. WHERE CARRYING MEMBERS ARE
<br />SPLICED, AVOID VISIBLE DISPLACEMENT OF FACE PLANE OF
<br />ADJACENT MEMBERS.
<br />E. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR
<br />SPACING OF HANGERS, REINFORCE THE NEAREST AFFECTED
<br />HANGERS AND RELATED CARRYING CHANNELS TO SPAN THE EXTRA
<br />DISTANCE.
<br />F. DO NOT SUPPORT COMPONENTS ON MAIN RUNNERS OR CROSS
<br />RUNNERS IF WEIGHT CAUSES TOTAL DEAD LOAD TO EXCEED
<br />DEFLECTION CAPABILITY.
<br />G. SUPPORT FIXTURE LOADS USING SUPPLEMENTARY HANGERS
<br />LOCATED WITHIN 6 INCHES (150 MM) OF EACH CORNER, OR SUPPORT
<br />COMPONENTS INDEPENDENTLY.
<br />H. DO NOT ECCENTRICALLY LOAD SYSTEM OR INDUCE ROTATION OF
<br />RUNNERS.
<br />I. PERIMETER MOLDING: INSTALL AT INTERSECTION OF CEILING AND
<br />VERTICAL SURFACES AND AT JUNCTIONS WITH OTHER
<br />INTERRUPTIONS.
<br />1. USE LONGEST PRACTICAL LENGTHS.
<br />2. OVERLAP AND RIVET CORNERS.
<br />3.03 INSTALLATION - ACOUSTICAL UNITS
<br />A. INSTALL ACOUSTICAL UNITS IN ACCORDANCE WITH MANUFACTURER'S
<br />INSTRUCTIONS.
<br />B. FIT ACOUSTICAL UNITS IN PLACE, FREE FROM DAMAGED EDGES OR
<br />OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION.
<br />C. FIT BORDER TRIM NEATLY AGAINST ABUTTING SURFACES.
<br />D. INSTALL UNITS AFTER ABOVE -CEILING WORK IS COMPLETE.
<br />E. INSTALL ACOUSTICAL UNITS LEVEL, IN UNIFORM PLANE, AND FREE
<br />FROM TWIST, WARP, AND DENTS.
<br />F. CUTTING ACOUSTICAL UNITS:
<br />1. CUT TO FIT IRREGULAR GRID AND PERIMETER EDGE TRIM.
<br />2. MAKE FIELD CUT EDGES OF SAME PROFILE AS FACTORY
<br />EDGES.
<br />3. DOUBLE CUT AND FIELD PAINT EXPOSED REVEAL EDGES.
<br />G. INSTALL HOLD-DOWN CLIPS ON PANELS WITHIN 20 FT (6 M) OF AN
<br />EXTERIOR DOOR.
<br />3.04 ERECTION TOLERANCES
<br />A. MAXIMUM VARIATION FROM FLAT AND LEVEL SURFACE: 1/8 INCH IN 10
<br />FEET (3 MM IN 3 M).
<br />B. MAXIMUM VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY
<br />ECCENTRIC LOADS: 2 DEGREES.
<br />END OF SECTION
<br />RESILIENT FLOORING - 096500
<br />PART 1 GENERAL (NOT USED)
<br />PART 2 PRODUCTS
<br />2.01 VCT MEETING FEDERAL SPECIFICATION SS-T-312B (1) TYPE IV,
<br />COMPOSITION 1
<br />A. TILE: AS MANUFACTURED BY ARMSTRONG
<br />1. SIZE: 12"X12"Xi/8"
<br />B. TEXTURES/COLORS: SEE FINISH SCHEDULE.
<br />C. VINYL BASE WITH COVE: AS MANUFACTURED BY ARMSTRONG
<br />1. HEIGHT: AS INDICATED ON FINISH SCHEDULE.
<br />2. THICKNESS: .080"
<br />3. COLOR: REFER TO FINISH SCHEDULE.
<br />D. ADHESIVE: PER MANUFACTURERS RECOMMENDATION
<br />E. INITIAL MAINTENANCE AFTER INSTALLATION: ARMSTRONG
<br />COMMERCIAL VINYL COMPOSITION TILES ARE COATED WITH FAST
<br />START FACTORY FINISH. IT DOES NOT REQUIRE REMOVAL AFTER
<br />INSTALLATION. IT IS COMPATIBLE WITH COMMERCIAL FLOOR
<br />POLISHES AND ELIMINATES THE NEED TO STRIP THE TILE.
<br />F. IMMEDIATELY AFTER VCT INSTALLATION, AND PRIOR TO STORE
<br />FIXTURE DELIVERY, G.C. SHALL TO DO THE FOLLOWING:
<br />1. SWEEP OR VACUUM THE FLOOR THOROUGHLY.
<br />2. DAMP -MOP THE FLOOR WITH A NEUTRAL DETERGENT
<br />SOLUTION SUCH AS ARMSTRONG S-485 FLOOR CLEANER,
<br />WHILE CAREFULLY REMOVING BLACK MARKS AND EXCESSIVE
<br />SOIL. DO NOT MACHINE SCRUB THE FLOOR FOR AT LEAST
<br />FOUR TO FIVE DAYS AFTER INSTALLATION, TO PREVENT
<br />EXCESS MOISTURE FROM INTERFERING WITH THE ADHESIVE
<br />BOND.
<br />3. APPLY (2) COATS OF A HIGH -QUALITY COMMERCIAL FLOOR
<br />POLISH SUCH AS ARMSTRONG S-480 FLOOR POLISH OR A
<br />HIGH -QUALITY STAIN -RESISTANT SEALER SUCH AS
<br />ARMSTRONG S-495 FLOOR SEALER. ALLOW APPROPRIATE
<br />DRYING TIME BETWEEN APPLICATIONS. POLISH TO BE MOP
<br />APPLIED AS REQUIRED BY POLISH MANUFACTURER.
<br />4. IN NO INSTANCE SHALL NEW VCT BE PLACED OVER EXISTING
<br />VCT. EXISTING VCT SHALL BE REMOVED AND SLAB PREPARED
<br />TO RECEIVE NEW VCT.
<br />END OF SECTION
<br />DECORATIVE FIBERGLASS REINFORCED
<br />WALL PANELS - 097200
<br />PART 1 GENERAL (NOT USED)
<br />PART 2 PRODUCTS
<br />2.01 FIBERGLASS WALL PANELS
<br />A. MANUFACTURER: MARLITE
<br />1.
<br />FIBERGLASS REINFORCED THERMOSETTING POLYESTER RESIN
<br />PANEL SHEETS COMPLYING WITH ASTM D 5319.
<br />2.
<br />COATING: MULTI LAYER PRINT, PRIMER AND FINISH COATS.
<br />3.
<br />DIMENSIONS:
<br />a. THICKNESS - 0.090 INCH (2.29MM) NOMINAL
<br />b. WIDTH - 4'-0- (1.22M) NOMINAL
<br />c. LENGTH -8'-0" (2.4M) NOMINAL
<br />4.
<br />COLOR AND FINISH
<br />d. COLOR: AS INDICATED ON PLANS
<br />e. SURFACE PEBBLED (INDICATED BY "P" DESIGNATION)
<br />5.
<br />MOLDINGS -PVC: EXTRUDED PVC TRIM PROFILES FOR .090 INCH
<br />THICK PANELS.
<br />a. M 350 INSIDE CORNER
<br />b. M 365 DIVISION
<br />c. M 370 EDGE
<br />c.1. COLOR: AS INDICATED ON PLANS
<br />6.
<br />OUTSIDE CORNER GUARD; PROVIDE IMPACT SPECIALTIES
<br />OUTSIDE CORNER GUARDS REFER TO SECTION 102600 WALL
<br />AND DOOR PROTECTION
<br />7.
<br />FASTENERS: NON -STAINING NYLON DRIVE RIVETS.
<br />a. MATCH WALL COLORS.
<br />b. LENGTH TO SUIT PROJECT CONDITIONS.
<br />8.
<br />ADHESIVE: EITHER OF THE FOLLOWING CONSTRUCTION
<br />ADHESIVES COMPLYING WITH ASTM C 557.
<br />a. MARLITE C-551 FRP ADHESIVE - WATER- RESISTANT,
<br />NON-FLAMMABLE ADHESIVE
<br />PART 3: EXECUTION
<br />A. PREPARATION
<br />1.
<br />LEVEL WALL SURFACES TO PANEL MANUFACTURER'S
<br />REQUIREMENTS. REMOVE PROTRUSIONS AND FILL
<br />INDENTATIONS.
<br />2.
<br />STORE PANELS AND TRIM LYING FLAT, UNDER COVER AND
<br />PROTECTED FROM THE ELEMENTS. ALLOW PANELS TO
<br />ACCLIMATE TO ROOM TEMPERATURE (70") FOR 48 HOURS
<br />PRIOR TO INSTALLATION.
<br />B. INSTALLATION
<br />1.
<br />COMPLY WITH MANUFACTURER'S RECOMMENDED
<br />PROCEDURES AND INSTALLATION SEQUENCE.
<br />2.
<br />CAULK TOP AND BOTTOM OF WALL PANEL TRIM AT WALL.
<br />3.
<br />CAULK TOP AND BOTTOM OF CORNER GUARD AT WALL.
<br />C. CLEANING
<br />1.
<br />REFER TO MANUFACTURER'S SPECIFIC CLEANING
<br />RECOMMENDATIONS DO NOT USE ABRASIVE CLEANERS.
<br />END OF SECTION
<br />SECTION 099100 - PAINTING
<br />PART 1 GENERAL
<br />1.01 SECTION INCLUDES
<br />A. SURFACE PREPARATION.
<br />B. FIELD APPLICATION OF PAINTS AND OTHER COATINGS.
<br />C. SEE SCHEDULE - SURFACES TO BE FINISHED, AT END OF SECTION.
<br />1.02 REFERENCES
<br />A. ASTM D 16 - STANDARD TERMINOLOGY FOR PAINT, RELATED
<br />COATINGS, MATERIALS, AND APPLICATIONS, 2000.
<br />1.03 QUALITY ASSURANCE
<br />A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN
<br />MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH
<br />MINIMUM THREE YEARS DOCUMENTED EXPERIENCE.
<br />B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN
<br />PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 5 YEARS
<br />EXPERIENCE.
<br />1.04 REGULATORY REQUIREMENTS
<br />A. CONFORM TO APPLICABLE CODE FOR FLAME AND SMOKE RATING
<br />REQUIREMENTS FOR PRODUCTS AND FINISHES.
<br />1.05 DELIVERY, STORAGE, AND PROTECTION
<br />A. DELIVER PRODUCTS TO SITE IN SEALED AND LABELED CONTAINERS,
<br />INSPECT TO VERIFY ACCEPTABILITY.
<br />B. CONTAINER LABEL: INCLUDE MANUFACTURER'S NAME, TYPE OF
<br />PAINT, BRAND NAME, LOT NUMBER, BRAND CODE, COVERAGE,
<br />SURFACE PREPARATION, DRYING TIME, CLEANUP REQUIREMENTS,
<br />COLOR DESIGNATION, AND INSTRUCTIONS FOR MIXING AND
<br />REDUCING.
<br />C. PAINT MATERIALS: STORE AT MINIMUM AMBIENT TEMPERATURE OF 45
<br />DEGREES F (7 DEGREES C) AND A MAXIMUM OF 90 DEGREES F (32
<br />DEGREES C), IN VENTILATED AREA, AND AS REQUIRED BY
<br />MANUFACTURER'S INSTRUCTIONS.
<br />1.06 ENVIRONMENTAL REQUIREMENTS
<br />A. DO NOT APPLY MATERIALS WHEN SURFACE AND AMBIENT
<br />TEMPERATURES ARE OUTSIDE THE TEMPERATURE RANGES
<br />REQUIRED BY THE PAINT PRODUCT MANUFACTURER.
<br />B. DO NOT APPLY EXTERIOR COATINGS DURING RAIN OR SNOW, OR
<br />WHEN RELATIVE HUMIDITY IS OUTSIDE THE HUMIDITY RANGES
<br />REQUIRED BY THE PAINT PRODUCT MANUFACTURER.
<br />C. MINIMUM APPLICATION TEMPERATURES FOR LATEX PAINTS: 45
<br />DEGREES F (7 DEGREES C) FOR INTERIORS, 50 DEGREES F (10
<br />DEGREES C) FOR EXTERIOR, UNLESS REQUIRED OTHERWISE BY
<br />MANUFACTURER'S INSTRUCTIONS.
<br />D. PROVIDE LIGHTING LEVEL OF 80 FT CANDLES (860 LX) MEASURED
<br />MID -HEIGHT AT SUBSTRATE SURFACE.
<br />1.07 EXTRA MATERIALS
<br />A. SEE SECTION 016000 -PRODUCT REQUIREMENTS, FOR ADDITIONAL
<br />PROVISIONS.
<br />B. SUPPLY 1 GALLON (4 L) OF EACH COLOR, STORE WHERE DIRECTED.
<br />C. LABEL EACH CONTAINER WITH COLOR IN ADDITION TO THE
<br />MANUFACTURER'S LABEL.
<br />PART 2 PRODUCTS
<br />2.01 MANUFACTURERS
<br />A. REFER TO FINISH SCHEDULE.
<br />B. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT REQUIREMENTS.
<br />2.02 PAINTS AND COATINGS - GENERAL
<br />D. INTERIOR METAL DOORS, FRAMES, BOLLARDS, BUILDING COLUMNS
<br />A.
<br />PAINTS AND COATINGS: READY MIXED, EXCEPT FIELD -CATALYZED
<br />NOT AT ROOF STRUCTURE, - LOW-ODOR/LOW VOC, LATEX BASED
<br />COATINGS. PREPARE PIGMENTS:
<br />SEMI -GLOSS.
<br />1. TO A SOFT PASTE CONSISTENCY, CAPABLE OF BEING READILY
<br />1. COAT #1 SHERWIN-WILLIAMS PRO INDUSTRIAL PRO-CRYL
<br />AND UNIFORMLY DISPERSED TO A HOMOGENEOUS COATING.
<br />UNIVERSAL PRIMER, B66 SERIES (5-10 MILS WET, 1.8-3.6
<br />MILS DRY).
<br />2. FOR GOOD FLOW AND BRUSHING PROPERTIES.
<br />2. COAT #2 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLICSEMI-GLOSS,
<br />3. CAPABLE OF DRYING OR CURING FREE OF STREAKS OR SAGS.
<br />B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY)
<br />2.03 ACCESSORY MATERIALS
<br />3. COAT #3 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLIC
<br />A.
<br />ACCESSORY MATERIALS: LINSEED OIL, SHELLAC, TURPENTINE, PAINT
<br />SEMI -GLOSS, B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY)
<br />THINNERS AND OTHER MATERIALS NOT SPECIFICALLY INDICATED BUT
<br />E. EXTERIOR METAL DOORS, FRAMES AND BOLLARDS - SEMI -GLOSS
<br />REQUIRED TO ACHIEVE THE FINISHES SPECIFIED, COMMERCIAL
<br />ACRYLIC COATING.
<br />QUALITY.
<br />1. COAT #1 SHERWIN-WILLIAMS PRO INDUSTRIAL PRO-CRYL
<br />B.
<br />PATCHING MATERIAL: LATEX FILLER.
<br />UNIVERSAL PRIMER, B66-310 SERIES (5-10 MILS WET, 2-4
<br />C.
<br />FASTENER HEAD COVER MATERIAL: LATEX FILLER.
<br />MILS DRY).
<br />PART 3 EXECUTION
<br />2. COAT #2 SHERWIN-WILLIAMS PRO INDUSTRIAL
<br />3.01 EXAMINATION
<br />WATERBASED ALKYD URETHANE ENAMEL SEMI -GLOSS,
<br />A.
<br />VERIFY THAT SURFACES ARE READY TO RECEIVE WORK AS
<br />B53 SERIES (4-5 MIL WET, 1.4 -1.7 MIL DRY).
<br />INSTRUCTED BY THE PRODUCT MANUFACTURER.
<br />3. COAT #3 SHERWIN-WILLIAMS PRO INDUSTRIAL
<br />B.
<br />EXAMINE SURFACES SCHEDULED TO BE FINISHED PRIOR TO
<br />WATERBASED ALKYD URETHANE ENAMEL SEMI -GLOSS,
<br />COMMENCEMENT OF WORK. REPORT ANY CONDITION THAT MAY
<br />B53 SERIES (4-5 MIL WET, 1.4 -1.7 MIL DRY).
<br />POTENTIALLY AFFECT PROPER APPLICATION.
<br />F. METAL ROOF DECK - DRYFALL WATERBORNE TOPCOATS
<br />C.
<br />TEST SHOP -APPLIED PRIMER FOR COMPATIBILITY WITH SUBSEQUENT
<br />1. PRIME AS NEEDED PER MANUFACTURERS INSTRUCTIONS
<br />COVER MATERIALS.
<br />2. COAT #1 SHERWIN-WILLIAMS WATERBORNE ACRYLIC
<br />3.02 PREPARATION
<br />DRYFALL, FLAT, B42 SERIES (6-9 MILS WET, 1.5-2.3 MILS
<br />A.
<br />SURFACE APPURTENANCES: REMOVE OR MASK ELECTRICAL PLATES,
<br />DRY)
<br />HARDWARE, LIGHT FIXTURE TRIM, ESCUTCHEONS, AND FITTINGS
<br />3. COAT #2 SHERWIN-WILLIAMS WATERBORNE ACRYLIC
<br />PRIOR TO PREPARING SURFACES OR FINISHING.
<br />DRYFALL, FLAT, B42 SERIES (6-9 MILS WET, 1.5-2.3 MILS
<br />B.
<br />SURFACES: CORRECT DEFECTS AND CLEAN SURFACES WHICH
<br />DRY)
<br />AFFECT WORK OF THIS SECTION. REMOVE OR REPAIR EXISTING
<br />COATINGS THAT EXHIBIT SURFACE DEFECTS.
<br />END OF SECTION
<br />C.
<br />MARKS: SEAL WITH SHELLAC THOSE WHICH MAY BLEED THROUGH
<br />SURFACE FINISHES.
<br />D.
<br />IMPERVIOUS SURFACES: REMOVE MILDEW BY SCRUBBING WITH
<br />SOLUTION OF TETRA -SODIUM PHOSPHATE AND BLEACH. RINSE WITH
<br />CLEAN WATER AND ALLOW SURFACE TO DRY.
<br />E.
<br />CONCRETE AND UNIT MASONRY SURFACES TO BE PAINTED: REMOVE
<br />DIRT, LOOSE MORTAR, SCALE, SALT OR ALKALI POWDER, AND OTHER
<br />FOREIGN MATTER. REMOVE OIL AND GREASE WITH A SOLUTION OF
<br />TRI-SODIUM PHOSPHATE, RINSE WELL AND ALLOW TO DRY. REMOVE
<br />STAINS CAUSED BY WEATHERING OF CORRODING METALS WITH A
<br />SOLUTION OF SODIUM METASILICATE AFTER THOROUGHLY WETTING
<br />WITH WATER. ALLOW TO DRY.
<br />F.
<br />GYPSUM BOARD SURFACES TO BE PAINTED: FILL MINOR DEFECTS
<br />WITH FILLER COMPOUND. SPOT PRIME DEFECTS AFTER REPAIR.
<br />G.
<br />GALVANIZED SURFACES TO BE PAINTED: REMOVE SURFACE
<br />CONTAMINATION AND OILS AND WASH WITH SOLVENT. APPLY COAT
<br />OF ETCHING PRIMER.
<br />H.
<br />UNCOATED STEEL AND IRON SURFACES TO BE PAINTED: REMOVE
<br />GREASE, MILL SCALE, WELD SPLATTER, DIRT, AND RUST. WHERE
<br />HEAVY COATINGS OF SCALE ARE EVIDENT, REMOVE BY HAND WIRE
<br />BRUSHING OR SANDBLASTING, CLEAN BY WASHING WITH SOLVENT.
<br />APPLY A TREATMENT OF PHOSPHORIC ACID SOLUTION, ENSURING
<br />WELD JOINTS, BOLTS, AND NUTS ARE SIMILARLY CLEANED. PRIME
<br />PAINT ENTIRE SURFACE, SPOT PRIME AFTER REPAIRS
<br />I.
<br />SHOP -PRIMED STEEL SURFACES TO BE FINISH PAINTED: SAND AND
<br />SCRAPE TO REMOVE LOOSE PRIMER AND RUST. FEATHER EDGES TO
<br />MAKE TOUCH-UP PATCHES INCONSPICUOUS. CLEAN SURFACES WITH
<br />SOLVENT. PRIME BARE STEEL SURFACES. RE -PRIME ENTIRE
<br />SHOP -PRIMED ITEM.
<br />J.
<br />METAL DOORS TO BE PAINTED: PRIME METAL DOOR TOP AND
<br />BOTTOM EDGE SURFACES.
<br />3.03 APPLICATION
<br />A.
<br />APPLY PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S
<br />INSTRUCTIONS.
<br />B.
<br />DO NOT APPLY FINISHES TO SURFACES THAT ARE NOT DRY. ALLOW
<br />APPLIED COATS TO DRY BEFORE NEXT COAT IS APPLIED.
<br />C.
<br />APPLY EACH COAT TO UNIFORM APPEARANCE. APPLY EACH COAT OF
<br />PAINT SLIGHTLY DARKER THAN PRECEDING COAT UNLESS
<br />OTHERWISE APPROVED.
<br />D.
<br />VACUUM CLEAN SURFACES OF LOOSE PARTICLES. USE TACK CLOTH
<br />TO REMOVE DUST AND PARTICLES JUST PRIOR TO APPLYING NEXT
<br />COAT.
<br />3.04 FINISHING MECHANICAL AND ELECTRICAL EQUIPMENT
<br />A.
<br />REFER TO SECTION 150500 FOR SCHEDULE OF COLOR CODING OF
<br />EQUIPMENT, DUCT WORK, PIPING, AND CONDUIT.
<br />B.
<br />PAINT SHOP -PRIMED EQUIPMENT, WHERE INDICATED.
<br />C.
<br />REMOVE UNFINISHED LOUVERS, GRILLES, COVERS, AND ACCESS
<br />PANELS ON MECHANICAL AND ELECTRICAL COMPONENTS AND PAINT
<br />SEPARATELY.
<br />D.
<br />FINISH EQUIPMENT, PIPING, CONDUIT, AND EXPOSED DUCT WORK IN
<br />COLORS ACCORDING TO THE COLOR CODING SCHEME INDICATED.
<br />E.
<br />REINSTALL ELECTRICAL COVER PLATES, HARDWARE, LIGHT FIXTURE
<br />TRIM, ESCUTCHEONS, AND FITTINGS REMOVED PRIOR TO FINISHING.
<br />3.05 CLEANING
<br />A.
<br />COLLECT WASTE MATERIAL WHICH MAY CONSTITUTE A FIRE HAZARD,
<br />PLACE IN CLOSED METAL CONTAINERS, AND REMOVE DAILY FROM
<br />SITE.
<br />3.06 SCHEDULE
<br />- SURFACES TO BE FINISHED
<br />A.
<br />DO NOT PAINT OR FINISH THE FOLLOWING ITEMS:
<br />1. ITEMS FULLY FACTORY -FINISHED UNLESS SPECIFICALLY NOTED.
<br />2. FIRE RATING LABELS, EQUIPMENT SERIAL NUMBER AND
<br />CAPACITY LABELS.
<br />B.
<br />PAINT THE SURFACES DESCRIBED BELOW UNDER SCHEDULE -PAINT
<br />SYSTEMS.
<br />C.
<br />MECHANICAL AND ELECTRICAL: USE PAINT SYSTEMS DEFINED FOR
<br />THE SUBSTRATES TO BE FINISHED.
<br />1. PAINT ALL INSULATED AND EXPOSED PIPES OCCURRING IN
<br />FINISHED AREAS TO MATCH BACKGROUND SURFACES, UNLESS
<br />OTHERWISE INDICATED.
<br />2. PAINT SHOP -PRIMED ITEMS OCCURRING IN FINISHED AREAS.
<br />3.07 SCHEDULE- PAINT SYSTEMS
<br />A.
<br />INTERIOR WALLS - LOW ODOR/ ZERO VOC, LATEX BASED EGGSHELL
<br />UNLESS NOTED OTHERWISE IN FINISH SCHEDULE.
<br />1. COAT #1 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR
<br />LATEX PRIMER, B28 SERIES (4 MIL WET, 1.0 MIL DRY).
<br />2. COAT #2 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR
<br />LATEX EG-SHELL, B20 SERIES (4 MIL WET, 1.7 MIL DRY).
<br />3. COAT #3 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR
<br />LATEX EG-SHELL, B20 SERIES (4 MIL WET, 1.7 MIL DRY).
<br />B.
<br />INTERIOR WALLS - TOILET ROOM, PET WASH, SEMI GLOSS UNLESS
<br />NOTED OTHERWISE IN FINISH SCHEDULE
<br />1. COAT #1 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR
<br />LATEX PRIMER, B28 SERIES (4 MIL WET, 1.0 MIL DRY).
<br />2. COAT #2 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR
<br />LATEX SEMI -GLOSS, B31 SERIES (4 MIL WET, 1.5 MIL DRY).
<br />3. COAT #3 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR
<br />LATEX SEMI -GLOSS, B31 SERIES (4 MIL WET, 1.5 MIL DRY).
<br />C.
<br />WOOD TRIM AND DOORS - LOW-ODOR/LOW VOC, LATEX BASED
<br />SEMI -GLOSS.
<br />1. COAT #1 SHERWIN-WILLIAMS PREPRITE PROBLOCK LATEX, B51
<br />SERIES (4 MIL WET, 1.4 MIL DRY).
<br />2. COAT #2 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLIC
<br />SEMI -GLOSS, B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY)
<br />3. COAT #3 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLIC
<br />SEMI -GLOSS, B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY)
<br />E
<br />Mo�8
<br />r r
<br />N
<br />o
<br />er er
<br />E
<br />IF
<br />4
<br />inft
<br />d Lg
<br />Z
<br />O
<br />H
<br />a_
<br />tY
<br />co
<br />W
<br />0
<br />W
<br />H
<br />Q
<br />W
<br />m
<br />a+w 'tea •r_�y,
<br />ss•sr• (V.`
<br />N
<br />Lo
<br />J
<br />Ju-
<br />0 �
<br />-i
<br />ILL. ILL.
<br />W �-
<br />N2
<br />N
<br />co
<br />Z
<br />D0
<br />U�
<br />wv
<br />LL
<br />= CU
<br />Uw
<br />w ♦�a-
<br />VJ
<br />ISSUED FOR:
<br />PERMIT
<br />03.14.19
<br />BID
<br />03.14.19
<br />CONSTRUCTION
<br />00.00.00
<br />REVIEW SET
<br />03.14.19
<br />PROJECT MANAGER DESIGNER
<br />SS SS
<br />JOB NO.
<br />18390
<br />AS1 m6
<br />
|