Laserfiche WebLink
SECTION 093000 -TILING <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. <br />THIS SECTION INCLUDES THE FOLLOWING: <br />1. GLAZED WALL TILE. <br />2. QUARRY TILE AND BASE. <br />3. METAL EDGE STRIPS INSTALLED AS PART OF TILE <br />INSTALLATIONS. <br />1.2 EXTRA MATERIALS <br />A. <br />FURNISH EXTRA MATERIALS DESCRIBED BELOW THAT MATCH <br />PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE <br />COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING <br />CONTENTS. <br />1. TILE AND TRIM UNITS: FURNISH QUANTITY OF FULL-SIZE UNITS <br />EQUAL TO 3 PERCENT OF AMOUNT INSTALLED, FOR EACH <br />TYPE, COMPOSITION, COLOR, PATTERN, AND SIZE INDICATED. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. <br />PROVIDE PRODUCTS FROM MANUFACTURERS AS SCHEDULED ON <br />DRAWINGS. <br />2.2 TILE <br />PRODUCTS <br />A. <br />MANUFACTURERS: AS SCHEDULED ON DRAWINGS. <br />B. <br />PROVIDE TRIM PIECES, BULLNOSE TILE, COVED BASEINSIDE AND <br />OUTSIDE CORNERS NECESSARY FOR PROJECT INSTALLATION. <br />2.3 SETTING AND GROUTING MATERIALS <br />A. <br />AVAILABLE MANUFACTURERS: REFER TO FINISH SCHEDULE. <br />B. <br />LATEX-PORTLAND CEMENT MORTAR (THIN SET): ANSI A118.4. <br />1. PREPACKAGED DRY -MORTAR MIX COMBINED WITH <br />LIQUID -LATEX ADDITIVE. <br />2. FOR WALL APPLICATIONS, PROVIDE NONSAGGING MORTAR. <br />C. <br />POLYMER -MODIFIED TILE GROUT: ANSI A118.7, COLOR AS INDICATED. <br />2.4 MISCELLANEOUS MATERIALS <br />A. <br />TRANSITION AND EDGE TRIMS. PROVIDE SCHLUTER TRIMS AS <br />INDICATED ON DRAWINGS. <br />PART 3 - EXECUTION <br />3.1 PREPARATION <br />A. <br />REMOVE COATINGS, INCLUDING CURING COMPOUNDS AND OTHER <br />SUBSTANCES THAT CONTAIN SOAP, WAX, OIL, OR SILICONE, THAT ARE <br />INCOMPATIBLE WITH TILE -SETTING MATERIALS. <br />B. <br />FILL CRACKS, HOLES, AND DEPRESSIONS WITH TROWELABLE <br />LEVELING AND PATCHING COMPOUND ACCORDING TO TILE -SETTING <br />MATERIAL MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />C. <br />REMOVE PROTRUSIONS, BUMPS, AND RIDGES BY SANDING OR <br />GRINDING. <br />D. <br />BLENDING: FOR TILE EXHIBITING COLOR VARIATIONS, USE FACTORY <br />BLENDED TILE OR BLEND TILES AT PROJECT SITE BEFORE <br />INSTALLING. <br />E. <br />FIELD -APPLIED TEMPORARY PROTECTIVE COATING: WHERE <br />INDICATED UNDER TILE TYPE OR NEEDED TO PREVENT GROUT FROM <br />STAINING OR ADHERING TO EXPOSED TILE SURFACES, PRECOAT <br />THEM WITH CONTINUOUS FILM OF TEMPORARY PROTECTIVE COATING, <br />TAKING CARE NOT TO COAT UNEXPOSED TILE SURFACES. <br />3.2 INSTALLATION, GENERAL <br />A. <br />ANSI TILE INSTALLATION STANDARDS: COMPLY WITH PARTS OF ANSI <br />A108 SERIES "SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE" <br />THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND <br />TO METHODS INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES. <br />B. <br />TCA INSTALLATION GUIDELINES: TCA'S "HANDBOOK FOR CERAMIC <br />TILE INSTALLATION." COMPLY WITH TCA INSTALLATION METHODS <br />INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES. <br />C. <br />EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND <br />EQUIPMENT AND FIXTURES TO FORM COMPLETE COVERING WITHOUT <br />INTERRUPTIONS, UNLESS OTHERWISE INDICATED. TERMINATE WORK <br />NEATLY AT OBSTRUCTIONS, EDGES, AND CORNERS WITHOUT <br />DISRUPTING PATTERN OR JOINT ALIGNMENTS. <br />D. <br />ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM <br />CUTTING AND DRILLING OF TILE WITHOUT MARRING VISIBLE <br />SURFACES. GRIND CUT EDGES OF TILE ABUTTING TRIM, FINISH, OR <br />BUILT-IN ITEMS. FIT TILE CLOSELY TO ELECTRICAL OUTLETS, PIPING, <br />FIXTURES, AND OTHER PENETRATIONS SO PLATES, COLLARS, OR <br />COVERS OVERLAP TILE. <br />E. <br />JOINTING PATTERN: LAY TILE IN GRID PATTERN, UNLESS OTHERWISE <br />INDICATED. ALIGN JOINTS WHEN ADJOINING TILES ON FLOOR, BASE, <br />WALLS, AND TRIM ARE SAME SIZE. LAY OUT TILE WORK AND CENTER <br />TILE FIELDS IN BOTH DIRECTIONS IN EACH SPACE OR ON EACH WALL <br />AREA. ADJUST TO MINIMIZE TILE CUTTING. PROVIDE UNIFORM JOINT <br />WIDTHS, UNLESS OTHERWISE INDICATED. <br />F. <br />LAY OUT TILE WAINSCOTS TO NEXT FULL TILE BEYOND DIMENSIONS <br />INDICATED. <br />G. <br />EXPANSION JOINTS: LOCATE EXPANSION JOINTS AND OTHER <br />SEALANT -FILLED JOINTS DURING INSTALLATION OF SETTING <br />MATERIALS, MORTAR BEDS, AND TILE. DO NOT SAW -CUT JOINTS <br />AFTER INSTALLING TILES. <br />1. LOCATE JOINTS IN TILE SURFACES DIRECTLY ABOVE JOINTS IN <br />CONCRETE SUBSTRATES. <br />2. PREPARE JOINTS AND APPLY SEALANTS TO COMPLY WITH <br />REQUIREMENTS IN DIVISION 07 SECTION "JOINT SEALANTS." <br />H. <br />FOR INSTALLATIONS INDICATED BELOW, FOLLOW PROCEDURES IN <br />ANSI A108 SERIES TILE INSTALLATION STANDARDS FOR PROVIDING 95 <br />PERCENT MORTAR COVERAGE. <br />1. TILE FLOORS IN WET AREAS. <br />2. TILE FLOORS COMPOSED OF TILES 8 BY 8 INCHES (200 BY 200 <br />MM) OR LARGER. <br />3. TILE FLOORS COMPOSED OF RIB -BACKED TILES. <br />1. <br />INSTALL TILE ON FLOORS WITH THE FOLLOWING JOINT WIDTHS: <br />1. PORCELAIN CERAMIC: 1/4 INCH (6.35 MM). <br />2. QUARRY TILE: 318 INCH (6.35 MM). <br />K. <br />METAL EDGE STRIPS: INSTALL AT LOCATIONS INDICATED OR WHERE <br />EXPOSED EDGE OF TILE FLOORING MEETS CARPET, WOOD, OR OTHER <br />FLOORING THAT FINISHES FLUSH WITH TOP OF TILE. <br />L. <br />INSTALL TILE ON WALLS WITH THE FOLLOWING JOINT WIDTHS: <br />1. GLAZED WALL TILE: 1/16 INCH (1.6 MM). <br />3.3 WALL TILE INSTALLATION SCHEDULE <br />A. <br />INTERIOR WALL INSTALLATION, THIN -SET MORTAR, OVER GYPSUM <br />BOARD, TCA W243. <br />1. THIN -SET MORTAR: LAYTEX-PORTLAND CEMENT MORTAR. <br />2. GROUT: POLYMER -MODIFIED SANDED GROUT. <br />END OF SECTION <br />SECTION 095113 - ACOUSTICAL PANEL CEILINGS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. SUSPENDED METAL GRID CEILING SYSTEM. <br />B. ACOUSTICAL UNITS. <br />1.02 REFERENCES <br />A. ASTM C 635 - STANDARD SPECIFICATION FOR THE MANUFACTURE, <br />PERFORMANCE, AND TESTING OF METAL SUSPENSION SYSTEMS FOR <br />ACOUSTICAL TILE AND LAY -IN PANEL CEILINGS, 2000. <br />B. ASTM C 636 - STANDARD PRACTICE FOR INSTALLATION OF METAL <br />CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY -IN <br />PANELS, 1996. <br />C. ASTM E 1264 - STANDARD CLASSIFICATION FOR ACOUSTICAL CEILING <br />PRODUCTS, 1998. <br />D. LATEST EDITION OF CISCA - GUIDELINES FOR SEISMIC RESTRAINT FOR <br />DIRECT HUNG SUSPENDED CEILING ASSEMBLIES. <br />1.03 QUALITY ASSURANCE <br />A. ACOUSTICAL UNIT MANUFACTURER QUALIFICATIONS: COMPANY <br />SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS <br />SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE. <br />1.04 ENVIRONMENTAL REQUIREMENTS <br />A. MAINTAIN UNIFORM TEMPERATURE OF MINIMUM 60 DEGREES F (16 <br />DEGREES C), AND MAXIMUM HUMIDITY OF 40 PERCENT PRIOR TO, <br />DURING, AND AFTER ACOUSTICAL UNIT INSTALLATION. <br />1.05 PROJECT CONDITIONS <br />A. SEQUENCE WORK TO ENSURE ACOUSTICAL CEILINGS ARE NOT <br />INSTALLED UNTIL BUILDING IS ENCLOSED, SUFFICIENT HEAT IS <br />PROVIDED, DUST GENERATING ACTIVITIES HAVE TERMINATED, AND <br />OVERHEAD WORK IS COMPLETED, TESTED, AND APPROVED. <br />B. INSTALL ACOUSTICAL UNITS AFTER INTERIOR WET WORK IS DRY. <br />PART 2 PRODUCTS <br />2.01 ACOUSTICAL UNITS <br />A. REFER TO DRAWING SCHEDULE. <br />2.02 SUSPENSION SYSTEM(S) <br />A. MANUFACTURERS: <br />1. REFER TO FINISH SCHEDULE. <br />2. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT <br />REQUIREMENTS. <br />B. SUSPENSION SYSTEMS - GENERAL: ASTM C 635, DIE CUT AND <br />INTERLOCKING COMPONENTS, WITH STABILIZER BARS, CLIPS, <br />SPLICES, PERIMETER MOLDINGS, AND HOLD DOWN CLIPS AS <br />REQUIRED. <br />2.03 ACCESSORIES <br />A. SUPPORT CHANNELS AND HANGERS: GALVANIZED STEEL, SIZE AND <br />TYPE TO SUIT APPLICATION AND CEILING SYSTEM FLATNESS <br />REQUIREMENT SPECIFIED. <br />B. PERIMETER MOLDINGS: SAME MATERIAL AND FINISH AS GRID. <br />C. TOUCH-UP PAINT: TYPE AND COLOR TO MATCH ACOUSTICAL AND <br />GRID UNITS. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK. <br />B. VERIFY THAT LAYOUT OF HANGERS WILL NOT INTERFERE WITH <br />OTHER WORK. <br />3.02 INSTALLATION - SUSPENSION SYSTEM <br />A. INSTALL SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C 636 AND <br />MANUFACTURER'S INSTRUCTIONS AND AS SUPPLEMENTED IN THIS <br />SECTION. <br />B. RIGIDLY SECURE SYSTEM, INCLUDING INTEGRAL MECHANICAL AND <br />ELECTRICAL COMPONENTS, FOR MAXIMUM DEFLECTION OF 1:360. <br />C. INSTALL AFTER MAJOR ABOVE -CEILING WORK IS COMPLETE. <br />COORDINATE THE LOCATION OF HANGERS WITH OTHER WORK. <br />D. HANG SUSPENSION SYSTEM INDEPENDENT OF WALLS, COLUMNS, <br />DUCTS, PIPES AND CONDUIT. WHERE CARRYING MEMBERS ARE <br />SPLICED, AVOID VISIBLE DISPLACEMENT OF FACE PLANE OF <br />ADJACENT MEMBERS. <br />E. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR <br />SPACING OF HANGERS, REINFORCE THE NEAREST AFFECTED <br />HANGERS AND RELATED CARRYING CHANNELS TO SPAN THE EXTRA <br />DISTANCE. <br />F. DO NOT SUPPORT COMPONENTS ON MAIN RUNNERS OR CROSS <br />RUNNERS IF WEIGHT CAUSES TOTAL DEAD LOAD TO EXCEED <br />DEFLECTION CAPABILITY. <br />G. SUPPORT FIXTURE LOADS USING SUPPLEMENTARY HANGERS <br />LOCATED WITHIN 6 INCHES (150 MM) OF EACH CORNER, OR SUPPORT <br />COMPONENTS INDEPENDENTLY. <br />H. DO NOT ECCENTRICALLY LOAD SYSTEM OR INDUCE ROTATION OF <br />RUNNERS. <br />I. PERIMETER MOLDING: INSTALL AT INTERSECTION OF CEILING AND <br />VERTICAL SURFACES AND AT JUNCTIONS WITH OTHER <br />INTERRUPTIONS. <br />1. USE LONGEST PRACTICAL LENGTHS. <br />2. OVERLAP AND RIVET CORNERS. <br />3.03 INSTALLATION - ACOUSTICAL UNITS <br />A. INSTALL ACOUSTICAL UNITS IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />B. FIT ACOUSTICAL UNITS IN PLACE, FREE FROM DAMAGED EDGES OR <br />OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. <br />C. FIT BORDER TRIM NEATLY AGAINST ABUTTING SURFACES. <br />D. INSTALL UNITS AFTER ABOVE -CEILING WORK IS COMPLETE. <br />E. INSTALL ACOUSTICAL UNITS LEVEL, IN UNIFORM PLANE, AND FREE <br />FROM TWIST, WARP, AND DENTS. <br />F. CUTTING ACOUSTICAL UNITS: <br />1. CUT TO FIT IRREGULAR GRID AND PERIMETER EDGE TRIM. <br />2. MAKE FIELD CUT EDGES OF SAME PROFILE AS FACTORY <br />EDGES. <br />3. DOUBLE CUT AND FIELD PAINT EXPOSED REVEAL EDGES. <br />G. INSTALL HOLD-DOWN CLIPS ON PANELS WITHIN 20 FT (6 M) OF AN <br />EXTERIOR DOOR. <br />3.04 ERECTION TOLERANCES <br />A. MAXIMUM VARIATION FROM FLAT AND LEVEL SURFACE: 1/8 INCH IN 10 <br />FEET (3 MM IN 3 M). <br />B. MAXIMUM VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY <br />ECCENTRIC LOADS: 2 DEGREES. <br />END OF SECTION <br />RESILIENT FLOORING - 096500 <br />PART 1 GENERAL (NOT USED) <br />PART 2 PRODUCTS <br />2.01 VCT MEETING FEDERAL SPECIFICATION SS-T-312B (1) TYPE IV, <br />COMPOSITION 1 <br />A. TILE: AS MANUFACTURED BY ARMSTRONG <br />1. SIZE: 12"X12"Xi/8" <br />B. TEXTURES/COLORS: SEE FINISH SCHEDULE. <br />C. VINYL BASE WITH COVE: AS MANUFACTURED BY ARMSTRONG <br />1. HEIGHT: AS INDICATED ON FINISH SCHEDULE. <br />2. THICKNESS: .080" <br />3. COLOR: REFER TO FINISH SCHEDULE. <br />D. ADHESIVE: PER MANUFACTURERS RECOMMENDATION <br />E. INITIAL MAINTENANCE AFTER INSTALLATION: ARMSTRONG <br />COMMERCIAL VINYL COMPOSITION TILES ARE COATED WITH FAST <br />START FACTORY FINISH. IT DOES NOT REQUIRE REMOVAL AFTER <br />INSTALLATION. IT IS COMPATIBLE WITH COMMERCIAL FLOOR <br />POLISHES AND ELIMINATES THE NEED TO STRIP THE TILE. <br />F. IMMEDIATELY AFTER VCT INSTALLATION, AND PRIOR TO STORE <br />FIXTURE DELIVERY, G.C. SHALL TO DO THE FOLLOWING: <br />1. SWEEP OR VACUUM THE FLOOR THOROUGHLY. <br />2. DAMP -MOP THE FLOOR WITH A NEUTRAL DETERGENT <br />SOLUTION SUCH AS ARMSTRONG S-485 FLOOR CLEANER, <br />WHILE CAREFULLY REMOVING BLACK MARKS AND EXCESSIVE <br />SOIL. DO NOT MACHINE SCRUB THE FLOOR FOR AT LEAST <br />FOUR TO FIVE DAYS AFTER INSTALLATION, TO PREVENT <br />EXCESS MOISTURE FROM INTERFERING WITH THE ADHESIVE <br />BOND. <br />3. APPLY (2) COATS OF A HIGH -QUALITY COMMERCIAL FLOOR <br />POLISH SUCH AS ARMSTRONG S-480 FLOOR POLISH OR A <br />HIGH -QUALITY STAIN -RESISTANT SEALER SUCH AS <br />ARMSTRONG S-495 FLOOR SEALER. ALLOW APPROPRIATE <br />DRYING TIME BETWEEN APPLICATIONS. POLISH TO BE MOP <br />APPLIED AS REQUIRED BY POLISH MANUFACTURER. <br />4. IN NO INSTANCE SHALL NEW VCT BE PLACED OVER EXISTING <br />VCT. EXISTING VCT SHALL BE REMOVED AND SLAB PREPARED <br />TO RECEIVE NEW VCT. <br />END OF SECTION <br />DECORATIVE FIBERGLASS REINFORCED <br />WALL PANELS - 097200 <br />PART 1 GENERAL (NOT USED) <br />PART 2 PRODUCTS <br />2.01 FIBERGLASS WALL PANELS <br />A. MANUFACTURER: MARLITE <br />1. <br />FIBERGLASS REINFORCED THERMOSETTING POLYESTER RESIN <br />PANEL SHEETS COMPLYING WITH ASTM D 5319. <br />2. <br />COATING: MULTI LAYER PRINT, PRIMER AND FINISH COATS. <br />3. <br />DIMENSIONS: <br />a. THICKNESS - 0.090 INCH (2.29MM) NOMINAL <br />b. WIDTH - 4'-0- (1.22M) NOMINAL <br />c. LENGTH -8'-0" (2.4M) NOMINAL <br />4. <br />COLOR AND FINISH <br />d. COLOR: AS INDICATED ON PLANS <br />e. SURFACE PEBBLED (INDICATED BY "P" DESIGNATION) <br />5. <br />MOLDINGS -PVC: EXTRUDED PVC TRIM PROFILES FOR .090 INCH <br />THICK PANELS. <br />a. M 350 INSIDE CORNER <br />b. M 365 DIVISION <br />c. M 370 EDGE <br />c.1. COLOR: AS INDICATED ON PLANS <br />6. <br />OUTSIDE CORNER GUARD; PROVIDE IMPACT SPECIALTIES <br />OUTSIDE CORNER GUARDS REFER TO SECTION 102600 WALL <br />AND DOOR PROTECTION <br />7. <br />FASTENERS: NON -STAINING NYLON DRIVE RIVETS. <br />a. MATCH WALL COLORS. <br />b. LENGTH TO SUIT PROJECT CONDITIONS. <br />8. <br />ADHESIVE: EITHER OF THE FOLLOWING CONSTRUCTION <br />ADHESIVES COMPLYING WITH ASTM C 557. <br />a. MARLITE C-551 FRP ADHESIVE - WATER- RESISTANT, <br />NON-FLAMMABLE ADHESIVE <br />PART 3: EXECUTION <br />A. PREPARATION <br />1. <br />LEVEL WALL SURFACES TO PANEL MANUFACTURER'S <br />REQUIREMENTS. REMOVE PROTRUSIONS AND FILL <br />INDENTATIONS. <br />2. <br />STORE PANELS AND TRIM LYING FLAT, UNDER COVER AND <br />PROTECTED FROM THE ELEMENTS. ALLOW PANELS TO <br />ACCLIMATE TO ROOM TEMPERATURE (70") FOR 48 HOURS <br />PRIOR TO INSTALLATION. <br />B. INSTALLATION <br />1. <br />COMPLY WITH MANUFACTURER'S RECOMMENDED <br />PROCEDURES AND INSTALLATION SEQUENCE. <br />2. <br />CAULK TOP AND BOTTOM OF WALL PANEL TRIM AT WALL. <br />3. <br />CAULK TOP AND BOTTOM OF CORNER GUARD AT WALL. <br />C. CLEANING <br />1. <br />REFER TO MANUFACTURER'S SPECIFIC CLEANING <br />RECOMMENDATIONS DO NOT USE ABRASIVE CLEANERS. <br />END OF SECTION <br />SECTION 099100 - PAINTING <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. SURFACE PREPARATION. <br />B. FIELD APPLICATION OF PAINTS AND OTHER COATINGS. <br />C. SEE SCHEDULE - SURFACES TO BE FINISHED, AT END OF SECTION. <br />1.02 REFERENCES <br />A. ASTM D 16 - STANDARD TERMINOLOGY FOR PAINT, RELATED <br />COATINGS, MATERIALS, AND APPLICATIONS, 2000. <br />1.03 QUALITY ASSURANCE <br />A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN <br />MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH <br />MINIMUM THREE YEARS DOCUMENTED EXPERIENCE. <br />B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN <br />PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 5 YEARS <br />EXPERIENCE. <br />1.04 REGULATORY REQUIREMENTS <br />A. CONFORM TO APPLICABLE CODE FOR FLAME AND SMOKE RATING <br />REQUIREMENTS FOR PRODUCTS AND FINISHES. <br />1.05 DELIVERY, STORAGE, AND PROTECTION <br />A. DELIVER PRODUCTS TO SITE IN SEALED AND LABELED CONTAINERS, <br />INSPECT TO VERIFY ACCEPTABILITY. <br />B. CONTAINER LABEL: INCLUDE MANUFACTURER'S NAME, TYPE OF <br />PAINT, BRAND NAME, LOT NUMBER, BRAND CODE, COVERAGE, <br />SURFACE PREPARATION, DRYING TIME, CLEANUP REQUIREMENTS, <br />COLOR DESIGNATION, AND INSTRUCTIONS FOR MIXING AND <br />REDUCING. <br />C. PAINT MATERIALS: STORE AT MINIMUM AMBIENT TEMPERATURE OF 45 <br />DEGREES F (7 DEGREES C) AND A MAXIMUM OF 90 DEGREES F (32 <br />DEGREES C), IN VENTILATED AREA, AND AS REQUIRED BY <br />MANUFACTURER'S INSTRUCTIONS. <br />1.06 ENVIRONMENTAL REQUIREMENTS <br />A. DO NOT APPLY MATERIALS WHEN SURFACE AND AMBIENT <br />TEMPERATURES ARE OUTSIDE THE TEMPERATURE RANGES <br />REQUIRED BY THE PAINT PRODUCT MANUFACTURER. <br />B. DO NOT APPLY EXTERIOR COATINGS DURING RAIN OR SNOW, OR <br />WHEN RELATIVE HUMIDITY IS OUTSIDE THE HUMIDITY RANGES <br />REQUIRED BY THE PAINT PRODUCT MANUFACTURER. <br />C. MINIMUM APPLICATION TEMPERATURES FOR LATEX PAINTS: 45 <br />DEGREES F (7 DEGREES C) FOR INTERIORS, 50 DEGREES F (10 <br />DEGREES C) FOR EXTERIOR, UNLESS REQUIRED OTHERWISE BY <br />MANUFACTURER'S INSTRUCTIONS. <br />D. PROVIDE LIGHTING LEVEL OF 80 FT CANDLES (860 LX) MEASURED <br />MID -HEIGHT AT SUBSTRATE SURFACE. <br />1.07 EXTRA MATERIALS <br />A. SEE SECTION 016000 -PRODUCT REQUIREMENTS, FOR ADDITIONAL <br />PROVISIONS. <br />B. SUPPLY 1 GALLON (4 L) OF EACH COLOR, STORE WHERE DIRECTED. <br />C. LABEL EACH CONTAINER WITH COLOR IN ADDITION TO THE <br />MANUFACTURER'S LABEL. <br />PART 2 PRODUCTS <br />2.01 MANUFACTURERS <br />A. REFER TO FINISH SCHEDULE. <br />B. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT REQUIREMENTS. <br />2.02 PAINTS AND COATINGS - GENERAL <br />D. INTERIOR METAL DOORS, FRAMES, BOLLARDS, BUILDING COLUMNS <br />A. <br />PAINTS AND COATINGS: READY MIXED, EXCEPT FIELD -CATALYZED <br />NOT AT ROOF STRUCTURE, - LOW-ODOR/LOW VOC, LATEX BASED <br />COATINGS. PREPARE PIGMENTS: <br />SEMI -GLOSS. <br />1. TO A SOFT PASTE CONSISTENCY, CAPABLE OF BEING READILY <br />1. COAT #1 SHERWIN-WILLIAMS PRO INDUSTRIAL PRO-CRYL <br />AND UNIFORMLY DISPERSED TO A HOMOGENEOUS COATING. <br />UNIVERSAL PRIMER, B66 SERIES (5-10 MILS WET, 1.8-3.6 <br />MILS DRY). <br />2. FOR GOOD FLOW AND BRUSHING PROPERTIES. <br />2. COAT #2 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLICSEMI-GLOSS, <br />3. CAPABLE OF DRYING OR CURING FREE OF STREAKS OR SAGS. <br />B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY) <br />2.03 ACCESSORY MATERIALS <br />3. COAT #3 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLIC <br />A. <br />ACCESSORY MATERIALS: LINSEED OIL, SHELLAC, TURPENTINE, PAINT <br />SEMI -GLOSS, B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY) <br />THINNERS AND OTHER MATERIALS NOT SPECIFICALLY INDICATED BUT <br />E. EXTERIOR METAL DOORS, FRAMES AND BOLLARDS - SEMI -GLOSS <br />REQUIRED TO ACHIEVE THE FINISHES SPECIFIED, COMMERCIAL <br />ACRYLIC COATING. <br />QUALITY. <br />1. COAT #1 SHERWIN-WILLIAMS PRO INDUSTRIAL PRO-CRYL <br />B. <br />PATCHING MATERIAL: LATEX FILLER. <br />UNIVERSAL PRIMER, B66-310 SERIES (5-10 MILS WET, 2-4 <br />C. <br />FASTENER HEAD COVER MATERIAL: LATEX FILLER. <br />MILS DRY). <br />PART 3 EXECUTION <br />2. COAT #2 SHERWIN-WILLIAMS PRO INDUSTRIAL <br />3.01 EXAMINATION <br />WATERBASED ALKYD URETHANE ENAMEL SEMI -GLOSS, <br />A. <br />VERIFY THAT SURFACES ARE READY TO RECEIVE WORK AS <br />B53 SERIES (4-5 MIL WET, 1.4 -1.7 MIL DRY). <br />INSTRUCTED BY THE PRODUCT MANUFACTURER. <br />3. COAT #3 SHERWIN-WILLIAMS PRO INDUSTRIAL <br />B. <br />EXAMINE SURFACES SCHEDULED TO BE FINISHED PRIOR TO <br />WATERBASED ALKYD URETHANE ENAMEL SEMI -GLOSS, <br />COMMENCEMENT OF WORK. REPORT ANY CONDITION THAT MAY <br />B53 SERIES (4-5 MIL WET, 1.4 -1.7 MIL DRY). <br />POTENTIALLY AFFECT PROPER APPLICATION. <br />F. METAL ROOF DECK - DRYFALL WATERBORNE TOPCOATS <br />C. <br />TEST SHOP -APPLIED PRIMER FOR COMPATIBILITY WITH SUBSEQUENT <br />1. PRIME AS NEEDED PER MANUFACTURERS INSTRUCTIONS <br />COVER MATERIALS. <br />2. COAT #1 SHERWIN-WILLIAMS WATERBORNE ACRYLIC <br />3.02 PREPARATION <br />DRYFALL, FLAT, B42 SERIES (6-9 MILS WET, 1.5-2.3 MILS <br />A. <br />SURFACE APPURTENANCES: REMOVE OR MASK ELECTRICAL PLATES, <br />DRY) <br />HARDWARE, LIGHT FIXTURE TRIM, ESCUTCHEONS, AND FITTINGS <br />3. COAT #2 SHERWIN-WILLIAMS WATERBORNE ACRYLIC <br />PRIOR TO PREPARING SURFACES OR FINISHING. <br />DRYFALL, FLAT, B42 SERIES (6-9 MILS WET, 1.5-2.3 MILS <br />B. <br />SURFACES: CORRECT DEFECTS AND CLEAN SURFACES WHICH <br />DRY) <br />AFFECT WORK OF THIS SECTION. REMOVE OR REPAIR EXISTING <br />COATINGS THAT EXHIBIT SURFACE DEFECTS. <br />END OF SECTION <br />C. <br />MARKS: SEAL WITH SHELLAC THOSE WHICH MAY BLEED THROUGH <br />SURFACE FINISHES. <br />D. <br />IMPERVIOUS SURFACES: REMOVE MILDEW BY SCRUBBING WITH <br />SOLUTION OF TETRA -SODIUM PHOSPHATE AND BLEACH. RINSE WITH <br />CLEAN WATER AND ALLOW SURFACE TO DRY. <br />E. <br />CONCRETE AND UNIT MASONRY SURFACES TO BE PAINTED: REMOVE <br />DIRT, LOOSE MORTAR, SCALE, SALT OR ALKALI POWDER, AND OTHER <br />FOREIGN MATTER. REMOVE OIL AND GREASE WITH A SOLUTION OF <br />TRI-SODIUM PHOSPHATE, RINSE WELL AND ALLOW TO DRY. REMOVE <br />STAINS CAUSED BY WEATHERING OF CORRODING METALS WITH A <br />SOLUTION OF SODIUM METASILICATE AFTER THOROUGHLY WETTING <br />WITH WATER. ALLOW TO DRY. <br />F. <br />GYPSUM BOARD SURFACES TO BE PAINTED: FILL MINOR DEFECTS <br />WITH FILLER COMPOUND. SPOT PRIME DEFECTS AFTER REPAIR. <br />G. <br />GALVANIZED SURFACES TO BE PAINTED: REMOVE SURFACE <br />CONTAMINATION AND OILS AND WASH WITH SOLVENT. APPLY COAT <br />OF ETCHING PRIMER. <br />H. <br />UNCOATED STEEL AND IRON SURFACES TO BE PAINTED: REMOVE <br />GREASE, MILL SCALE, WELD SPLATTER, DIRT, AND RUST. WHERE <br />HEAVY COATINGS OF SCALE ARE EVIDENT, REMOVE BY HAND WIRE <br />BRUSHING OR SANDBLASTING, CLEAN BY WASHING WITH SOLVENT. <br />APPLY A TREATMENT OF PHOSPHORIC ACID SOLUTION, ENSURING <br />WELD JOINTS, BOLTS, AND NUTS ARE SIMILARLY CLEANED. PRIME <br />PAINT ENTIRE SURFACE, SPOT PRIME AFTER REPAIRS <br />I. <br />SHOP -PRIMED STEEL SURFACES TO BE FINISH PAINTED: SAND AND <br />SCRAPE TO REMOVE LOOSE PRIMER AND RUST. FEATHER EDGES TO <br />MAKE TOUCH-UP PATCHES INCONSPICUOUS. CLEAN SURFACES WITH <br />SOLVENT. PRIME BARE STEEL SURFACES. RE -PRIME ENTIRE <br />SHOP -PRIMED ITEM. <br />J. <br />METAL DOORS TO BE PAINTED: PRIME METAL DOOR TOP AND <br />BOTTOM EDGE SURFACES. <br />3.03 APPLICATION <br />A. <br />APPLY PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />B. <br />DO NOT APPLY FINISHES TO SURFACES THAT ARE NOT DRY. ALLOW <br />APPLIED COATS TO DRY BEFORE NEXT COAT IS APPLIED. <br />C. <br />APPLY EACH COAT TO UNIFORM APPEARANCE. APPLY EACH COAT OF <br />PAINT SLIGHTLY DARKER THAN PRECEDING COAT UNLESS <br />OTHERWISE APPROVED. <br />D. <br />VACUUM CLEAN SURFACES OF LOOSE PARTICLES. USE TACK CLOTH <br />TO REMOVE DUST AND PARTICLES JUST PRIOR TO APPLYING NEXT <br />COAT. <br />3.04 FINISHING MECHANICAL AND ELECTRICAL EQUIPMENT <br />A. <br />REFER TO SECTION 150500 FOR SCHEDULE OF COLOR CODING OF <br />EQUIPMENT, DUCT WORK, PIPING, AND CONDUIT. <br />B. <br />PAINT SHOP -PRIMED EQUIPMENT, WHERE INDICATED. <br />C. <br />REMOVE UNFINISHED LOUVERS, GRILLES, COVERS, AND ACCESS <br />PANELS ON MECHANICAL AND ELECTRICAL COMPONENTS AND PAINT <br />SEPARATELY. <br />D. <br />FINISH EQUIPMENT, PIPING, CONDUIT, AND EXPOSED DUCT WORK IN <br />COLORS ACCORDING TO THE COLOR CODING SCHEME INDICATED. <br />E. <br />REINSTALL ELECTRICAL COVER PLATES, HARDWARE, LIGHT FIXTURE <br />TRIM, ESCUTCHEONS, AND FITTINGS REMOVED PRIOR TO FINISHING. <br />3.05 CLEANING <br />A. <br />COLLECT WASTE MATERIAL WHICH MAY CONSTITUTE A FIRE HAZARD, <br />PLACE IN CLOSED METAL CONTAINERS, AND REMOVE DAILY FROM <br />SITE. <br />3.06 SCHEDULE <br />- SURFACES TO BE FINISHED <br />A. <br />DO NOT PAINT OR FINISH THE FOLLOWING ITEMS: <br />1. ITEMS FULLY FACTORY -FINISHED UNLESS SPECIFICALLY NOTED. <br />2. FIRE RATING LABELS, EQUIPMENT SERIAL NUMBER AND <br />CAPACITY LABELS. <br />B. <br />PAINT THE SURFACES DESCRIBED BELOW UNDER SCHEDULE -PAINT <br />SYSTEMS. <br />C. <br />MECHANICAL AND ELECTRICAL: USE PAINT SYSTEMS DEFINED FOR <br />THE SUBSTRATES TO BE FINISHED. <br />1. PAINT ALL INSULATED AND EXPOSED PIPES OCCURRING IN <br />FINISHED AREAS TO MATCH BACKGROUND SURFACES, UNLESS <br />OTHERWISE INDICATED. <br />2. PAINT SHOP -PRIMED ITEMS OCCURRING IN FINISHED AREAS. <br />3.07 SCHEDULE- PAINT SYSTEMS <br />A. <br />INTERIOR WALLS - LOW ODOR/ ZERO VOC, LATEX BASED EGGSHELL <br />UNLESS NOTED OTHERWISE IN FINISH SCHEDULE. <br />1. COAT #1 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR <br />LATEX PRIMER, B28 SERIES (4 MIL WET, 1.0 MIL DRY). <br />2. COAT #2 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR <br />LATEX EG-SHELL, B20 SERIES (4 MIL WET, 1.7 MIL DRY). <br />3. COAT #3 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR <br />LATEX EG-SHELL, B20 SERIES (4 MIL WET, 1.7 MIL DRY). <br />B. <br />INTERIOR WALLS - TOILET ROOM, PET WASH, SEMI GLOSS UNLESS <br />NOTED OTHERWISE IN FINISH SCHEDULE <br />1. COAT #1 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR <br />LATEX PRIMER, B28 SERIES (4 MIL WET, 1.0 MIL DRY). <br />2. COAT #2 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR <br />LATEX SEMI -GLOSS, B31 SERIES (4 MIL WET, 1.5 MIL DRY). <br />3. COAT #3 SHERWIN-WILLIAMS PROMAR 200 ZERO VOC INTERIOR <br />LATEX SEMI -GLOSS, B31 SERIES (4 MIL WET, 1.5 MIL DRY). <br />C. <br />WOOD TRIM AND DOORS - LOW-ODOR/LOW VOC, LATEX BASED <br />SEMI -GLOSS. <br />1. COAT #1 SHERWIN-WILLIAMS PREPRITE PROBLOCK LATEX, B51 <br />SERIES (4 MIL WET, 1.4 MIL DRY). <br />2. COAT #2 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLIC <br />SEMI -GLOSS, B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY) <br />3. COAT #3 SHERWIN-WILLIAMS PRO INDUSTRIAL ACRYLIC <br />SEMI -GLOSS, B66 SERIES (6-12 MIL WET, 2.1-4.2 MIL DRY) <br />E <br />Mo�8 <br />r r <br />N <br />o <br />er er <br />E <br />IF <br />4 <br />inft <br />d Lg <br />Z <br />O <br />H <br />a_ <br />tY <br />co <br />W <br />0 <br />W <br />H <br />Q <br />W <br />m <br />a+w 'tea •r_�y, <br />ss•sr• (V.` <br />N <br />Lo <br />J <br />Ju- <br />0 � <br />-i <br />ILL. ILL. <br />W �- <br />N2 <br />N <br />co <br />Z <br />D0 <br />U� <br />wv <br />LL <br />= CU <br />Uw <br />w ♦�a- <br />VJ <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />PROJECT MANAGER DESIGNER <br />SS SS <br />JOB NO. <br />18390 <br />AS1 m6 <br />