SECTION 033000 - CAST -IN -PLACE CONCRETE <br />WALLS, GRADE BEAMS, AND OTHER LOCATIONS, AS INDICATED. <br />AND NOT LESS THAN 4 INCHES (100 MM) WIDE. <br />3.04 CONCRETE PLACEMENT <br />1. WIRE: FABRICATE FROM 3/16-INCH- (4.8-MM-) DIAMETER, <br />PART 1 - GENERAL <br />A. BEFORE PLACING CONCRETE, VERIFY THAT INSTALLATION OF <br />HOT -DIP GALVANIZED STEEL WIRE. <br />1.01 SUMMARY <br />FORMWORK, REINFORCEMENT, AND EMBEDDED ITEMS IS COMPLETE <br />2.8 EMBEDDED FLASHING MATERIALS <br />A. THIS SECTION SPECIFIES CAST -IN PLACE CONCRETE, INCLUDING <br />AND THAT REQUIRED INSPECTIONS HAVE BEEN PERFORMED. <br />A. <br />METAL FLASHING: COMPLY WITH SMACNA'S ARCHITECTURAL SHEET <br />FORMWORK, REINFORCEMENT, CONCRETE MATERIALS, MIXTURE <br />DESIGN, PLACEMENT PROCEDURES, AND FINISHES. <br />1. DEPOSIT CONCRETE CONTINUOUSLY IN ONE LAYER. <br />METAL MANUAL. <br />1.02 QUALITY ASSURANCE <br />B. PLACE CONCRETE OVER COMPACTED SUB -GRADE, MINIMUM 95% <br />B. <br />FLEXIBLE FLASHING: FOR FLASHING NOT EXPOSED TO THE EXTERIOR: <br />A. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN <br />DENSITY PER ASTM D1557. SUBMIT TEST REPORT TO OWNER. <br />1. COPPER -LAMINATED FLASHING: 7-OZ./SQ. FT. (2-KG/SQ. M) <br />MANUFACTURING READY -MIXED CONCRETE PRODUCTS AND THAT <br />3.05 FINISHING FLOORS AND SLABS <br />COPPER SHEET BONDED WITH ASPHALT BETWEEN 2 LAYERS <br />COMPLIES WITH ASTM C 94/C 94M REQUIREMENTS FOR PRODUCTION <br />A. GENERAL: COMPLY WITH ACI 302.1 R RECOMMENDATIONS FOR <br />OF GLASS -FIBER CLOTH. <br />FACILITIES AND EQUIPMENT. <br />SCREEDING, RESTRAIGHTENING, AND FINISHING OPERATIONS FOR <br />C. <br />SOLDER AND SEALANTS FOR SHEET METAL FLASHINGS: AS <br />1. MANUFACTURER CERTIFIED ACCORDING TO NRMCA'S <br />CONCRETE SURFACES. DO NOT WET CONCRETE SURFACES. <br />SPECIFIED BY FLASHING MANUFACTURER. <br />"CERTIFICATION OF READY MIXED CONCRETE PRODUCTION <br />B. FLOAT FINISH: CONSOLIDATE SURFACE WITH POWER -DRIVEN FLOATS <br />D. <br />ADHESIVES, PRIMERS, AND SEAM TAPES FOR FLASHINGS: AS <br />FACILITIES." <br />OR BY HAND FLOATING IF AREA IS SMALL OR INACCESSIBLE TO <br />RECOMMENDED BY FLASHING MANUFACTURER. <br />B. ACI PUBLICATIONS: COMPLY WITH THE FOLLOWING UNLESS MODIFIED <br />POWER DRIVEN FLOATS. CUT DOWN HIGH SPOTS, <br />, <br />2.9 MISCELLANEOUS <br />MASONRY ACCESSORIES <br />BY REQUIREMENTS IN THE CONTRACT DOCUMENTS: <br />AND FILL LOW SPOTS. REPEAT FLOAT PASSES AND <br />RESTRAIGHTENING UNTIL SURFACE IS LEFT WITH A UNIFORM, <br />A. <br />COMPRESSIBLE FILLER: PREMOLDED FILLER STRIPS COMPLYING <br />1. ACI 301, "SPECIFICATION FOR STRUCTURAL CONCRETE," <br />SMOOTH, GRANULAR TEXTURE. <br />WITH ASTM D 1056, GRADE 2A1, COMPRESSIBLE UP TO 35 PERCENT, <br />SECTIONS 1 THROUGH 5. <br />FORMULATED FROM NEOPRENE URETHANE OR PVC. <br />C. TROWEL FINISH: AFTER APPLYING FLOAT FINISH, APPLY FIRST <br />2. ACI 117, "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE <br />TROWELING AND CONSOLIDATE CONCRETE BY HAND OR <br />B. <br />PREFORMED CONTROL -JOINT GASKETS: MADE FROM <br />CONSTRUCTION AND MATERIALS." <br />POWER -DRIVEN TROWEL. CONTINUE TROWELING PASSES AND <br />STYRENE-BUTADIENE-RUBBER COMPOUND, COMPLYING WITH ASTM D <br />PART 2 - PRODUCTS <br />RESTRAIGHTEN UNTIL SURFACE IS FREE OF TROWEL MARKS AND <br />2000, DESIGNATION M2AA-805 AND DESIGNED TO FIT STANDARD SASH <br />2.01 STEEL REINFORCEMENT <br />UNIFORM IN TEXTURE AND APPEARANCE. GRIND SMOOTH ANY <br />BLOCK AND TO MAINTAIN LATERAL STABILITY IN MASONRY WALL. <br />SURFACE DEFECTS THAT WOULD TELEGRAPH THROUGH APPLIED <br />C. <br />BOND -BREAKER STRIPS: ASPHALT -SATURATED, ORGANIC ROOFING <br />A. REINFORCING BARS: ASTM A 615/A 615M, GRADE 60, DEFORMED. <br />COATINGS OR FLOOR COVERINGS. <br />FELT COMPLYING WITH ASTM D 226, TYPE I (NO. 15 ASPHALT FELT). <br />B. PLAIN -STEEL WELDED WIRE REINFORCEMENT: ASTM A 185, PLAIN, <br />D. BROOM FINISH: APPLY A BROOM FINISH TO EXTERIOR CONCRETE <br />D. <br />WEEPNENT PRODUCTS: USE ONE OF THE FOLLOWING, UNLESS <br />FABRICATED FROM AS -DRAWN STEEL WIRE INTO FLAT SHEETS. <br />PLATFORMS, STEPS, AND RAMPS, AND ELSEWHERE AS INDICATED. <br />OTHERWISE INDICATED: <br />C. BAR SUPPORTS: BOLSTERS, CHAIRS, SPACERS, AND OTHER DEVICES <br />3.06 CONCRETE PROTECTING AND CURING <br />1. RECTANGULAR PLASTIC WEEPNENT TUBING: CLEAR <br />FOR SPACING, SUPPORTING, AND FASTENING REINFORCING BARS <br />AND WELDED WIRE REINFORCEMENT IN PLACE. MANUFACTURE BAR <br />A. GENERAL: PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE <br />BUTYRATE, 3/8 BY 1-1/2 BY 3-1/2 INCHES (9 BY 38 BY 89 MM) <br />SUPPORTS FROM STEEL WIRE, PLASTIC, OR PRECAST CONCRETE <br />DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. COMPLY <br />LONG. <br />ACCORDING TO CRSI'S "MANUAL OF STANDARD PRACTICE." <br />WITH ACI 306.1 FOR COLD -WEATHER PROTECTION AND ACI 301 FOR <br />2.10 MASONRY CLEANERS <br />2.02 CONCRETE MATERIALS <br />HOT -WEATHER PROTECTION DURING CURING. <br />A. <br />PROPRIETARY ACIDIC CLEANER: MANUFACTURER'S <br />END OF SECTION <br />STANDARD -STRENGTH CLEANER DESIGNED FOR REMOVING <br />A. CEMENTITIOUS MATERIAL: USE THE FOLLOWING CEMENTITIOUS <br />MORTAR/GROUT STAINS FROM NEW MASONRY WITHOUT DAMAGINGMASONRY. <br />MATERIALS, OF THE SAME TYPE, BRAND, AND SOURCE, THROUGHOUT <br />USE PRODUCT APPROVED FOR INTENDED USE BY <br />PROJECT: <br />SECTION 033543 - SEALED AND POLISHED/DYED CONCRETE FINISHING <br />CLEANER MANUFACTURER AND MANUFACTURER OF MASONRY UNITS <br />1. PORTLAND CEMENT: ASTM C 150, TYPE I. <br />BEING CLEANED. <br />B. NORMAL -WEIGHT AGGREGATES: ASTM C 33, GRADED, 1-INCH (25-MM) <br />REFER TO SHEET AS1.7 FOR SPECIFICATION INFORMATION. <br />2.11 MORTAR AND GROUT MIXES <br />NOMINAL MAXIMUM COARSE -AGGREGATE SIZE. <br />A. <br />GENERAL: DO NOT USE ADMIXTURES, UNLESS OTHERWISE <br />1. FINE AGGREGATE: FREE OF MATERIALS WITH DELETERIOUS <br />INDICATED. <br />REACTIVITY TO ALKALI IN CEMENT. <br />SECTION 042000 - UNIT MASONRY <br />1. DO NOT USE CALCIUM CHLORIDE IN MORTAR OR GROUT. <br />C. WATER: ASTM C 94/C 94M AND POTABLE. <br />2. LIMIT CEMENTITIOUS MATERIALS IN MORTAR FOR EXTERIOR <br />D. AIR -ENTRAINING ADMIXTURE: ASTM C 260. <br />PART 1 - GENERAL <br />AND REINFORCED MASONRY TO PORTLAND CEMENT AND LIME. <br />E. CHEMICAL ADMIXTURES: PROVIDE ADMIXTURES CERTIFIED BY <br />1.1 SUMMARY <br />3. ADD COLD -WEATHER ADMIXTURE (IF USED) AT SAME RATE FOR <br />MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES AND <br />A. THIS SECTION INCLUDES UNIT MASONRY ASSEMBLIES CONSISTING OF <br />ALL MORTAR THAT WILL BE EXPOSED TO VIEW, REGARDLESS <br />THAT WILL NOT CONTRIBUTE WATER-SOLUBLE CHLORIDE IONS <br />THE FOLLOWING, <br />OF WEATHER CONDITIONS, TO ENSURE THAT MORTAR COLOR <br />EXCEEDING THOSE PERMITTED IN HARDENED CONCRETE. DO NOT <br />1. CONCRETE MASONRY UNITS (CMUS). <br />IS CONSISTENT. <br />USE CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM <br />2. DECORATIVE CONCRETE MASONRY UNITS. <br />B. <br />MORTAR FOR UNIT MASONRY: COMPLY WITH ASTM C 270, <br />CHLORIDE. <br />3. PRE -FACED CONCRETE MASONRY UNITS. <br />PROPORTION SPECIFICATION. <br />1. WATER -REDUCING ADMIXTURE: ASTM C 494/C 494M, TYPE A. <br />PART 3 -EXECUTION <br />2. RETARDING ADMIXTURE: ASTM C 494/C 494M, TYPE B. <br />4. CONCRETE BRICK. <br />3.1 INSTALLATION, GENERAL <br />3. WATER -REDUCING AND RETARDING ADMIXTURE: ASTM C 494/C <br />5. FACE BRICK. <br />A. <br />USE FULL-SIZE UNITS WITHOUT CUTTING IF POSSIBLE. IF CUTTING IS <br />494M, TYPE D. <br />6. HOLLOW BRICK. <br />REQUIRED, CUT UNITS WITH MOTOR -DRIVEN SAWS, PROVIDE CLEAN, <br />4. HIGH -RANGE, WATER -REDUCING ADMIXTURE: ASTM C 494/C <br />7. OTHER MATERIALS NECESSARY TO MATCH EXISTING BUILDING <br />SHARP, UN -CHIPPED EDGES. ALLOW UNITS TO DRY BEFORE LAYING <br />494M, TYPE F. <br />CONSTRUCTION. <br />UNLESS WETTING OF UNITS IS SPECIFIED. INSTALL CUT UNITS WITH <br />5. HIGH -RANGE, WATER -REDUCING AND RETARDING ADMIXTURE: <br />1.2 PROJECT CONDITIONS <br />CUT SURFACES AND, WHERE POSSIBLE, CUT EDGES CONCEALED. <br />ASTM C 494/C 494M, TYPE G. <br />A. COLD -WEATHER REQUIREMENTS: DO NOT USE FROZEN MATERIALS <br />B. <br />SELECT AND ARRANGE UNITS FOR EXPOSED UNIT MASONRY TO <br />6. PLASTICIZING AND RETARDING ADMIXTURE: ASTM C 1017/C <br />OR MATERIALS MIXED OR COATED WITH ICE OR FROST. DO NOT BUILD <br />PRODUCE A UNIFORM BLEND OF COLORS AND TEXTURES. <br />1017M, TYPE II. <br />ON FROZEN SUBSTRATES. REMOVE AND REPLACE UNIT MASONRY <br />C. <br />WETTING OF BRICK: WET BRICK BEFORE LAYING IF INITIAL RATE OF <br />2.03 VAPOR RETARDERS <br />DAMAGED BY FROST OR BY FREEZING CONDITIONS. COMPLY WITH <br />ABSORPTION EXCEEDS 30 G/30 SQ. IN. (30 G/194 SQ. CM) PER MINUTE <br />COLD -WEATHER CONSTRUCTION REQUIREMENTS CONTAINED IN ACI <br />WHEN TESTED PER ASTM C 67. ALLOW UNITS TO ABSORB WATER SO <br />A. PLASTIC VAPOR RETARDER: ASTM E 1745, CLASS B. INCLUDE <br />530.1/ASCE 6/TMS 602. <br />THEY ARE DAMP BUT NOT WET AT TIME OF LAYING. <br />MANUFACTURER'S RECOMMENDED ADHESIVE OR <br />PRESSURE -SENSITIVE TAPE. <br />B. HOT -WEATHER REQUIREMENTS: COMPLY WITH HOT -WEATHER <br />D. <br />COMPLY WITH TOLERANCES IN ACI 530.1/ASCE 6/TMS 602 AND WITH <br />CONSTRUCTION REQUIREMENTS CONTAINED IN ACI 530.1/ASCE 6/TMS <br />THE FOLLOWING: <br />2.04 CURING MATERIALS <br />602• <br />1. FOR CONSPICUOUS VERTICAL LINES, SUCH AS EXTERNAL <br />A. EVAPORATION RETARDER: WATERBORNE, MONOMOLECULAR FILM <br />PART 2 - PRODUCTS <br />CORNERS, DOOR JAMBS, REVEALS, AND EXPANSION AND <br />FORMING, MANUFACTURED FOR APPLICATION TO FRESH CONCRETE. <br />2.1 MANUFACTURERS <br />CONTROL JOINTS, DO NOT VARY FROM PLUMB BY MORE THAN <br />B. ABSORPTIVE COVER: AASHTO M 182, CLASS 2, BURLAP CLOTH MADE <br />A. IN OTHER PART 2 ARTICLES WHERE TITLES BELOW INTRODUCE LISTS, <br />1/8 INCH IN 10 FEET (3 MM IN 3 M), 1/4 INCH IN 20 FEET (6 MM IN <br />FROM JUTE OR KENAF, WEIGHING APPROXIMATELY 9 OZ./SQ. YD. (305 <br />THE FOLLOWING REQUIREMENTS APPLY TO PRODUCT SELECTION: <br />6 M), OR 1/2 INCH (12 MM) MAXIMUM. <br />G/SQ. M) WHEN DRY. <br />1. PROVIDE PRODUCTS FROM MANUFACTURERS THAT MEET <br />2. FOR CONSPICUOUS HORIZONTAL LINES, SUCH AS LINTELS, <br />C. MOISTURE -RETAINING COVER: ASTM C 171, POLYETHYLENE FILM OR <br />REQUIREMENTS. <br />SILLS, PARAPETS, AND REVEALS, DO NOT VARY FROM LEVEL <br />WHITE BURLAP -POLYETHYLENE SHEET. <br />BY MORE THAN 1/8 INCH IN 10 FEET (3 MM IN 3 M), 1/4 INCH IN 20 <br />D. WATER: POTABLE. <br />2.2 COLORS, TEXTURES, AND PATTERNS <br />FEET (6 MM IN 6 M), OR 1/2 INCH (12 MM) MAXIMUM. <br />2.05 RELATED MATERIALS <br />A. AS SCHEDULED ON DRAWINGS. <br />3.2 LAYING MASONRY WALLS <br />A. EXPANSION- AND ISOLATION -JOINT -FILLER STRIPS: ASTM D 1751, <br />2.3 CONCRETE MASONRY UNITS (CMUS) <br />A. <br />LAY OUT WALLS IN ADVANCE FOR ACCURATE SPACING OF SURFACE <br />ASPHALT -SATURATED CELLULOSIC FIBER. <br />A. SHAPES: PROVIDE SPECIAL SHAPES FOR LINTELS, CORNERS, JAMBS, <br />BOND PATTERNS WITH UNIFORM JOINT THICKNESSES AND FOR <br />2.06 CONCRETE MIXTURES <br />SASHES, MOVEMENT JOINTS, HEADERS, BONDING, AND OTHER <br />ACCURATE LOCATION OF OPENINGS, MOVEMENT -TYPE JOINTS, <br />SPECIAL CONDITIONS. <br />RETURNS, AND OFFSETS. AVOID USING LESS -THAN -HALF-SIZE UNITS, <br />A. PREPARE DESIGN MIXTURES FOR EACH TYPE AND STRENGTH OF <br />B. CONCRETE MASONRY UNITS: ASTM C 90. <br />PARTICULARLY AT CORNERS, JAMBS, AND, WHERE POSSIBLE, AT <br />CONCRETE, PROPORTIONED ON THE BASIS OF LABORATORY TRIAL <br />OTHER LOCATIONS. <br />MIXTURE OR FIELD TEST DATA, OR BOTH, ACCORDING TO ACI 301. <br />1. WEIGHT CLASSIFICATION: NORMAL WEIGHT. <br />2.4 BRICK <br />B. <br />BOND PATTERN FOR EXPOSED MASONRY: UNLESS OTHERWISE <br />B. PROPORTION NORMAL -WEIGHT CONCRETE MIXTURE AS FOLLOWS: <br />INDICATED, LAY EXPOSED MASONRY IN RUNNING BOND, DO NOT USE <br />1. MINIMUM COMPRESSIVE STRENGTH: 3000 PSI (27.6 MPA) AT 28 <br />A. GENERAL: PROVIDE SHAPES INDICATED AND AS FOLLOWS: <br />UNITS WITH LESS THAN NOMINAL 4-INCH (100-MM) HORIZONTAL FACE <br />DAYS. <br />1. FOR ENDS OF SILLS AND CAPS AND FOR SIMILAR <br />DIMENSIONS AT CORNERS OR JAMBS. <br />2. MAXIMUM WATER-CEMENTITIOUS MATERIALS RATIO: 0.45. <br />APPLICATIONS THAT WOULD OTHERWISE EXPOSE UNFINISHED <br />C. <br />BUILT-IN WORK: AS CONSTRUCTION PROGRESSES, BUILD IN ITEMS <br />3. SLUMP LIMIT: 5 INCHES (125 MM), PLUS OR MINUS 1 INCH (25 <br />BRICK SURFACES, PROVIDE UNITS WITHOUT CORES OR FROGS <br />SPECIFIED IN THIS AND OTHER SECTIONS. FILL IN SOLIDLY WITH <br />MM). <br />AND WITH EXPOSED SURFACES FINISHED. WHERE REQUIRED <br />MASONRY AROUND BUILT-IN ITEMS. <br />4. AIR CONTENT: 6 PERCENT, PLUS MINUS 1.5 PERCENT AT <br />TO MATCH EXISTING. <br />D. <br />FILL SPACE BETWEEN STEEL FRAMES AND MASONRY SOLIDLY WITH <br />POINT OF DELIVERY FOR 1-INCH (25-MM) NOMINAL MAXIMUM <br />2. PROVIDE SPECIAL SHAPES FOR APPLICATIONS WHERE SHAPES <br />MORTAR, UNLESS OTHERWISE INDICATED. <br />AGGREGATE SIZE. <br />PRODUCED BY SAWING WOULD RESULT IN SAWED SURFACES <br />E. <br />FILL CORES IN HOLLOW CONCRETE MASONRY UNITS WITH GROUT 24 <br />5. AIR CONTENT: DO NOT ALLOW AIR CONTENT OF TROWELED <br />BEING EXPOSED TO VIEW. <br />INCHES (600 MM) UNDER BEARING PLATES, BEAMS, LINTELS, POSTS, <br />FINISHED FLOORS TO EXCEED 3 PERCENT. <br />B. FACE BRICK: ASTM C 216 UBC STANDARD 21-1, GRADE SW, TYPE FBX. <br />AND SIMILAR ITEMS, UNLESS OTHERWISE INDICATED. <br />PART 3 - EXECUTION <br />C. HOLLOW BRICK: ASTM C 652, GRADE SW. <br />3.3 MORTAR BEDDING AND JOINTING <br />3.01 FORMWORK <br />2.6 REINFORCEMENT <br />A. <br />LAY HOLLOW BRICK AND CONCRETE MASONRY UNITS AS FOLLOWS: <br />A. DESIGN, ERECT, SHORE, BRACE, AND MAINTAIN FORMWORK <br />A. UNCOATED STEEL REINFORCING BARS: ASTM A 615/A 615M OR ASTM <br />1. WITH FACE SHELLS FULLY BEDDED IN MORTAR AND WITH HEAD <br />ACCORDING TO ACI 301 TO SUPPORT VERTICAL, LATERAL, STATIC, <br />A 996/A 996M, GRADE 60 (GRADE 420). <br />JOINTS OF DEPTH EQUAL TO BED JOINTS. <br />AND DYNAMIC LOADS, AND CONSTRUCTION LOADS THAT MIGHT BE <br />B. MASONRY JOINT REINFORCEMENT: ASTM A 951, MILL GALVANIZED, <br />2. WITH WEBS FULLY BEDDED IN MORTAR IN ALL COURSES OF <br />APPLIED, UNTIL STRUCTURE CAN SUPPORT SUCH LOADS. <br />CARBON -STEEL WIRE FOR INTERIOR WALLS AND HOT -DIP <br />PIERS, COLUMNS, AND PILASTERS. <br />3.02 STEEL REINFORCEMENT <br />GALVANIZED, CARBON -STEEL WIRE FOR EXTERIOR WALLS. <br />3. WITH WEBS FULLY BEDDED IN MORTAR IN GROUTED MASONRY, <br />A. GENERAL: COMPLY WITH CRSI'S "MANUAL OF STANDARD PRACTICE" <br />1. WIRE SIZE FOR SIDE RODS: W1.7 OR 0.148-INCH (3.8-MM) <br />INCLUDING STARTING COURSE ON FOOTINGS. <br />FOR PLACING REINFORCEMENT. <br />DIAMETER. <br />4. WITH ENTIRE UNITS, INCLUDING AREAS UNDER CELLS, FULLY <br />1. DO NOT CUT OR PUNCTURE VAPOR RETARDER. REPAIR <br />2. WIRE SIZE FOR CROSS RODS: W1.7 OR 0.148-INCH (3.8-MM) <br />BEDDED IN MORTAR AT STARTING COURSE ON FOOTINGS <br />DAMAGE AND RESEAL VAPOR RETARDER BEFORE PLACING <br />DIAMETER. <br />WHERE CELLS ARE NOT GROUTED. <br />CONCRETE. <br />3. WIRE SIZE FOR VENEER TIES: W2.8 OR 0.188-INCH (4.8-MM) <br />B. <br />LAY SOLID MASONRY UNITS WITH COMPLETELY FILLED BED AND HEAD <br />3.03 JOINTS <br />DIAMETER. <br />JOINTS, BUTTER ENDS WITH SUFFICIENT MORTAR TO FILL HEAD <br />4. SPACING OF CROSS RODS, TABS, AND CROSS TIES: NOT MORE <br />JOINTS AND SHOVE INTO PLACE. DO NOT DEEPLY FURROW BED <br />A. GENERAL: CONSTRUCT JOINTS TRUE TO LINE WITH FACES <br />THAN 16 INCHES (407 MM) O.C. <br />JOINTS OR SLUSH HEAD JOINTS. <br />PERPENDICULAR TO SURFACE PLANE OF CONCRETE. <br />5. SINGLE-WYTHE MASONRY: EITHER LADDER OR TRUSS TYPE <br />C. <br />TOOL EXPOSED JOINTS SLIGHTLY CONCAVE WHEN THUMBPRINT <br />B. CONSTRUCTION JOINTS: INSTALL SO STRENGTH AND APPEARANCE <br />WITH SINGLE PAIR OF SIDE RODS. <br />HARD, USING A JOINTER LARGER THAN JOINT THICKNESS, UNLESS <br />OF CONCRETE ARE NOT IMPAIRED, AT LOCATIONS INDICATED OR AS <br />OTHERWISE INDICATED. <br />APPROVED BY ARCHITECT. <br />6. MULTIWYTHE MASONRY: <br />C. CONTRACTION JOINTS IN SLABS -ON -GRADE: FORM WEAKENED -PLANE <br />A. LADDER TYPE WITH 1 SIDE ROD AT EACH FACE SHELL OF HOLLOW <br />D. <br />CUT JOINTS FLUSH FOR MASONRY WALLS TO RECEIVE PLASTER OR <br />CONTRACTION JOINTS, SECTIONING CONCRETE INTO AREAS AS <br />MASONRY UNITS MORE THAN 4 INCHES (100 MM) IN WIDTH, PLUS 1 <br />OTHER DIRECT -APPLIED FINISHES (OTHER THAN PAINT), UNLESS <br />INDICATED. CONSTRUCT CONTRACTION JOINTS FOR A DEPTH EQUAL <br />SIDE ROD AT EACH WYTHE OF MASONRY 4 INCHES (100 MM) OR LESS <br />OTHERWISE INDICATED. <br />TO AT LEAST ONE-FOURTH OF CONCRETE THICKNESS AS FOLLOWS: <br />IN WIDTH. <br />3.04 COMPOSITE MASONRY <br />1. GROOVED JOINTS: FORM CONTRACTION JOINTS AFTER INITIAL <br />2.7 TIES AND ANCHORS <br />A. <br />BOND WYTHES OF COMPOSITE MASONRY TOGETHER USING ONE OF <br />FLOATING BY GROOVING AND FINISHING EACH EDGE OF JOINT <br />A. MATERIALS: <br />THE FOLLOWING METHODS: <br />TO A RADIUS OF 1/8 INCH (3.2 MM). REPEAT GROOVING OF <br />1. HOT -DIP GALVANIZED, CARBON -STEEL WIRE: ASTM A 82, WITH <br />1. INDIVIDUAL METAL TIES: PROVIDE TIES AS SHOWN INSTALLED <br />CONTRACTION JOINTS AFTER APPLYING SURFACE FINISHES. <br />ASTM A 153/A 153M, CLASS B-2 COATING. <br />IN HORIZONTAL JOINTS, BUT NOT LESS THAN ONE METAL TIE <br />ELIMINATE GROOVER TOOL MARKS ON CONCRETE SURFACES. <br />FOR 2.67 SQ. FT. (0.25 SQ. M) OF WALL AREA SPACED NOT TO <br />2. SAWED JOINTS: FORM CONTRACTION JOINTS WITH POWER <br />2. STEEL SHEET, GALVANIZED AFTER FABRICATION: ASTM A <br />1008/A 1008M, COMMERCIAL STEEL, HOT -DIP GALVANIZED <br />EXCEED 24 INCHES (610 O.C. HORIZONTALLY AND 16 <br />SAWS EQUIPPED WITH SHATTERPROOF ABRASIVE OR <br />AFTER FABRICATION TO COMPLY WITH ASTM A 153/A 153M. <br />TI <br />INCHES (406 MM) O.C. VERTICALLY. STAGGER TIES <br />DIAMOND -RIMMED BLADES. CUT 1/8-INCH- (3.2-MM-) WIDE <br />ALTERNATE COURSES. PROVIDE ADDITIONAL TIES WITHIN 12 <br />JOINTS INTO CONCRETE WHEN CUTTING ACTION WILL NOT <br />3. STEEL PLATES, SHAPES, AND BARS: ASTM A 36/A 36M. <br />INCHES (305 MM) OF OPENINGS AND SPACE NOT MORE THAN <br />TEAR, ABRADE, OR OTHERWISE DAMAGE SURFACE AND <br />B. WIRE TIES, GENERAL: UNLESS OTHERWISE INDICATED, SIZE WIRE <br />36 INCHES (915 MM) APART AROUND PERIMETER OF OPENINGS. <br />BEFORE CONCRETE DEVELOPS RANDOM CONTRACTION <br />TIES TO EXTEND AT LEAST HALFWAY THROUGH VENEER BUT WITH AT <br />AT INTERSECTING AND ABUTTING WALLS, PROVIDE TIES AT NO <br />CRACKS. <br />LEAST 5/8-INCH (16-MM) COVER ON OUTSIDE FACE. OUTER ENDS OF <br />MORE THAN 24 INCHES (610 MM) O.C. VERTICALLY. <br />D. ISOLATION JOINTS IN SLABS -ON -GRADE: AFTER REMOVING <br />WIRES ARE BENT 90 DEGREES AND EXTEND 2 INCHES (50 MM) <br />2. MASONRY JOINT REINFORCEMENT: INSTALLED IN HORIZONTAL <br />FORMWORK, INSTALL JOINT -FILLER STRIPS AT SLAB JUNCTIONS WITH <br />PARALLEL TO FACE OF VENEER. <br />MORTAR JOINTS. <br />VERTICAL SURFACES, SUCH AS COLUMN PEDESTALS, FOUNDATION <br />C. INDIVIDUAL WIRE TIES: RECTANGULAR UNITS WITH CLOSED ENDS <br />B. <br />WHERE BED JOINTS OF BOTH WYTHES ALIGN, USE LADDER -TYPE <br />REINFORCEMENT EXTENDING ACROSS BOTH WYTHES. <br />C. WHERE BED JOINTS OF WYTHES DO NOT ALIGN, USE ADJUSTABLE <br />(TWO-PIECE) TYPE REINFORCEMENT WITH CONTINUOUS HORIZONTAL <br />WIRE IN FACING WYTHE ATTACHED TO TIES. <br />D. COLLAR JOINTS: SOLIDLY FILL COLLAR JOINTS BY PARGING FACE OF <br />FIRST WYTHE THAT IS LAID AND SHOVING UNITS OF OTHER WYTHE <br />INTO PLACE. <br />E. CORNERS: PROVIDE INTERLOCKING MASONRY UNIT BOND IN EACH <br />WYTHE AND COURSE AT CORNERS, UNLESS OTHERWISE INDICATED. <br />3.05 MASONRY JOINT REINFORCEMENT <br />A. GENERAL: INSTALL IN MORTAR WITH A MINIMUM COVER OF 5/8 INCH <br />(16 MM) ON EXTERIOR SIDE OF WALLS, 1/2 INCH (13 MM) ELSEWHERE. <br />LAP REINFORCEMENT A MINIMUM OF 6 INCHES (150 MM). <br />B. INTERRUPT JOINT REINFORCEMENT AT CONTROL AND EXPANSION <br />JOINTS, UNLESS OTHERWISE INDICATED. <br />C. PROVIDE CONTINUITY AT WALL INTERSECTIONS BY USING <br />PREFABRICATED T-SHAPED UNITS. <br />D. PROVIDE CONTINUITY AT CORNERS BY USING PREFABRICATED <br />L-SHAPED UNITS. <br />3.06 ANCHORING MASONRY VENEERS <br />A. ANCHOR MASONRY VENEERS TO WALL FRAMING OR CONCRETE AND <br />MASONRY BACKUP WITH MASONRY -VENEER ANCHORS TO COMPLY <br />WITH THE FOLLOWING REQUIREMENTS: <br />1. FASTEN SCREW -ATTACHED ANCHORS THROUGH SHEATHING <br />TO WALL FRAMING AND TO CONCRETE AND MASONRY BACKUP <br />WITH METAL FASTENERS OF TYPE INDICATED. . <br />2. EMBED TIE SECTIONS IN MASONRY JOINTS. <br />3. LOCATE ANCHOR SECTIONS TO ALLOW MAXIMUM VERTICAL <br />DIFFERENTIAL MOVEMENT OF TIES UP AND DOWN. <br />4. SPACE ANCHORS AS INDICATED, BUT NOT MORE THAN 16 <br />INCHES (406 MM) O.C. VERTICALLY AND 24 INCHES (610 MM) <br />O.C. HORIZONTALLY WITH NOT LESS THAN 1 ANCHOR FOR <br />EACH 2.67 SQ. FT. (0.25 SQ. M) OF WALL AREA. INSTALL <br />ADDITIONAL ANCHORS WITHIN 12 INCHES (305 MM) OF <br />OPENINGS AND AT INTERVALS, NOT EXCEEDING 36 INCHES (914 <br />MM), AROUND PERIMETER. <br />3.07 FLASHING, WEEP HOLES, CAVITY DRAINAGE, AND VENTS <br />A. GENERAL: INSTALL EMBEDDED FLASHING AND WEEP HOLES IN <br />MASONRY AT SHELF ANGLES, LINTELS, LEDGES, OTHER <br />OBSTRUCTIONS TO DOWNWARD FLOW OF WATER IN WALL, AND <br />WHERE INDICATED. <br />B. INSTALL FLASHING AS FOLLOWS, UNLESS OTHERWISE INDICATED: <br />1. PREPARE MASONRY SURFACES SO THEY ARE SMOOTH AND <br />FREE FROM PROJECTIONS THAT COULD PUNCTURE FLASHING. <br />WHERE FLASHING IS WITHIN MORTAR JOINT, PLACE <br />THROUGH -WALL FLASHING ON SLOPING BED OF MORTAR AND <br />COVER WITH MORTAR. BEFORE COVERING WITH MORTAR, <br />SEAL PENETRATIONS IN FLASHING AS RECOMMENDED BY <br />FLASHING MANUFACTURER. <br />2. AT LINTELS AND SHELF ANGLES, EXTEND FLASHING A MINIMUM <br />OF 6 INCHES (150 MM) INTO MASONRY AT EACH END. AT HEADS <br />AND SILLS, EXTEND FLASHING 6 INCHES (150 MM) AT ENDS AND <br />TURN UP NOT LESS THAN 2 INCHES (50 MM) TO FORM END <br />DAMS. <br />C. INSTALL WEEP HOLES IN HEAD JOINTS IN EXTERIOR WYTHES OF FIRST <br />COURSE OF MASONRY IMMEDIATELY ABOVE EMBEDDED FLASHING <br />AND AS FOLLOWS: <br />1. USE SPECIFIED WEEPNENT PRODUCTS TO FORM WEEP HOLES. <br />2. SPACE WEEP HOLES 24 INCHES (600 MM) O.C., UNLESS <br />OTHERWISE INDICATED. <br />3. COVER CAVITY SIDE OF WEEP HOLES WITH PLASTIC INSECT <br />SCREENING AT CAVITIES INSULATED WITH LOOSE -FILL <br />INSULATION. <br />D. PLACE CAVITY DRAINAGE MATERIAL IN CAVITIES TO COMPLY WITH <br />CONFIGURATION REQUIREMENTS FOR CAVITY DRAINAGE MATERIAL IN <br />PART 2 "MISCELLANEOUS MASONRY ACCESSORIES" ARTICLE. <br />3.08 REINFORCED UNIT MASONRY INSTALLATION <br />A. TEMPORARY FORMWORK AND SHORES: CONSTRUCT FORMWORK <br />AND SHORES AS NEEDED TO SUPPORT REINFORCED MASONRY <br />ELEMENTS DURING CONSTRUCTION. <br />1. CONSTRUCT FORMWORK TO PROVIDE SHAPE, LINE, AND <br />DIMENSIONS OF COMPLETED MASONRY AS INDICATED. MAKE <br />FORMS SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF <br />MORTAR AND GROUT. BRACE, TIE, AND SUPPORT FORMS TO <br />MAINTAIN POSITION AND SHAPE DURING CONSTRUCTION AND <br />CURING OF REINFORCED MASONRY. <br />2. DO NOT REMOVE FORMS AND SHORES UNTIL REINFORCED <br />MASONRY MEMBERS HAVE HARDENED SUFFICIENTLY TO <br />CARRY THEIR OWN WEIGHT AND OTHER TEMPORARY LOADS <br />THAT MAY BE PLACED ON THEM DURING CONSTRUCTION. <br />B. PLACING REINFORCEMENT: COMPLY WITH REQUIREMENTS IN ACI <br />530.1/ASCE 6/TMS 602. <br />C. GROUTING: DO NOT PLACE GROUT UNTIL ENTIRE HEIGHT OF <br />MASONRY TO BE GROUTED HAS ATTAINED ENOUGH STRENGTH TO <br />RESIST GROUT PRESSURE. <br />1. COMPLY WITH REQUIREMENTS IN ACI 530.1/ASCE 6/TMS 602 <br />FOR CLEANOUTS AND FOR GROUT PLACEMENT, INCLUDING <br />MINIMUM GROUT SPACE AND MAXIMUM POUR HEIGHT. <br />2. LIMIT HEIGHT OF VERTICAL GROUT POURS TO NOT MORE THAN <br />60 INCHES (1520 MM). <br />3.09 PARGING <br />A. PARGE EXTERIOR FACES OF BELOW -GRADE MASONRY WALLS, <br />WHERE INDICATED, IN 2 UNIFORM COATS TO A TOTAL THICKNESS OF <br />3/4 INCH (19 MM) WITH A STEEL -TROWEL FINISH. FORMA WASH AT <br />TOP OF PARGING AND A COVE AT BOTTOM. DAMP -CURE PARGING <br />FOR AT LEAST 24 HOURS AND PROTECT PARGING UNTIL CURED. <br />3.10 CLEANING <br />A. IN -PROGRESS CLEANING: CLEAN UNIT MASONRY AS WORK <br />PROGRESSES BY DRY BRUSHING TO REMOVE MORTAR FINS AND <br />SMEARS BEFORE TOOLING JOINTS. <br />B. FINAL CLEANING: AFTER MORTAR IS THOROUGHLY SET AND CURED, <br />CLEAN EXPOSED MASONRY AS FOLLOWS: <br />1. TEST CLEANING METHODS ON SAMPLE WALL PANEL, LEAVE <br />ONE-HALF OF PANEL UNCLEANED FOR COMPARISON <br />PURPOSES. <br />2. PROTECT ADJACENT SURFACES FROM CONTACT WITH <br />CLEANER. <br />3. WET WALL SURFACES WITH WATER BEFORE APPLYING <br />CLEANERS, REMOVE CLEANERS PROMPTLY BY RINSING <br />SURFACES THOROUGHLY WITH CLEAR WATER. <br />4. CLEAN BRICK BY BUCKET -AND -BRUSH HAND -CLEANING <br />METHOD DESCRIBED IN BIA TECHNICAL NOTES 20. <br />5. CLEAN MASONRY WITH A PROPRIETARY ACIDIC CLEANER <br />APPLIED ACCORDING TO MANUFACTURER'S WRITTEN <br />INSTRUCTIONS. <br />6. CLEAN CONCRETE MASONRY BY CLEANING METHOD <br />INDICATED IN NCMA TEK 8-2A APPLICABLE TO TYPE OF STAIN <br />ON EXPOSED SURFACES. <br />3.11 MASONRY WASTE DISPOSAL <br />A. WASTE DISPOSAL AS FILL MATERIAL: DISPOSE OF CLEAN MASONRY <br />WASTE, INCLUDING EXCESS OR SOIL -CONTAMINATED SAND, WASTE <br />MORTAR, AND BROKEN MASONRY UNITS, BY CRUSHING AND MIXING <br />WITH FILL MATERIAL AS FILL IS PLACED. <br />1. DO NOT DISPOSE OF MASONRY WASTE AS FILL WITHIN 18 <br />INCHES (450 MM) OF FINISHED GRADE. <br />2. REMOVE EXCESS CLEAN MASONRY WASTE THAT CANNOT BE <br />USED AS FILL, AS DESCRIBED ABOVE, AND OTHER MASONRY <br />WASTE, AND LEGALLY DISPOSE OF OFF OWNER'S PROPERTY. <br />END OF SECTION <br />SECTION 055000 - METAL FABRICATIONS <br />PART GENERAL <br />1.01 SECTION INCLUDES <br />A. <br />SHOP FABRICATED STEEL ITEMS. <br />1.02 REFERENCES <br />A. <br />ASTM A 36/A 36M - STANDARD SPECIFICATION FOR CARBON <br />STRUCTURAL STEEL, 2001. <br />B. <br />ASTM A 53/A 53M - STANDARD SPECIFICATION FOR PIPE, STEEL, BLACK <br />AND HOT -DIPPED, ZINC -COATED, WELDED AND SEAMLESS, 2002. <br />C. <br />ASTM A 123/A 123M - STANDARD SPECIFICATION FOR ZINC (HOT -DIP <br />GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS, 2002. <br />D. <br />ASTM A 153/A 153M - STANDARD SPECIFICATION FOR ZINC COATING <br />(HOT -DIP) ON IRON AND STEEL HARDWARE, 2002. <br />E. <br />ASTM A 283/A 283M - STANDARD SPECIFICATION FOR LOW AND <br />INTERMEDIATE TENSILE STRENGTH CARBON STEEL PLATES, 2000. <br />F. <br />ASTM A 325 - STANDARD SPECIFICATION FOR STRUCTURAL BOLTS, <br />STEEL, HEAT TREATED, 120/105 KSI MINIMUM TENSILE STRENGTH, <br />2002. <br />G. <br />ASTM A 325M - STANDARD SPECIFICATION FOR HIGH -STRENGTH <br />BOLTS FOR STRUCTURAL STEEL JOINTS (METRIC), 2000. <br />H. <br />ASTM A 501 - STANDARD SPECIFICATION FOR HOT -FORMED WELDED <br />AND SEAMLESS CARBON STEEL STRUCTURAL TUBING, 2001. <br />I. <br />AWS D1.1 - STRUCTURAL WELDING CODE - STEEL, AMERICAN WELDING <br />SOCIETY, 2002. <br />J. <br />SSPC-PAINT 20 - ZINC -RICH PRIMERS (TYPE I, "INORGANIC," AND TYPE <br />II, "ORGANIC"), SOCIETY FOR PROTECTIVE COATINGS, 2002. <br />K. <br />SSPC-SP 2 - HAND TOOL CLEANING, SOCIETY FOR PROTECTIVE <br />COATINGS, 1982 (ED. 2000). <br />PART 2 PRODUCTS <br />2.01 MATERIALS - STEEL <br />A. <br />STEEL SECTIONS: ASTM A 36/A 36M. <br />B. <br />STEEL TUBING: ASTM A 501 HOT -FORMED STRUCTURAL TUBING. <br />C. <br />PLATES: ASTM A 283. <br />D. <br />PIPE: ASTM A 53/A 53M, GRADE B SCHEDULE 40, BLACK FINISH. <br />E. <br />BOLTS, NUTS, AND WASHERS: ASTM A 325 (ASTM A 325M), TYPE 1, <br />GALVANIZED TO ASTM A 153/A 153M WHERE CONNECTING <br />GALVANIZED COMPONENTS. <br />F. <br />WELDING MATERIALS: AWS 131.1, TYPE REQUIRED FOR MATERIALS <br />BEING WELDED. <br />G. <br />TOUCH-UP PRIMER FOR GALVANIZED SURFACES: SSPC-PAINT 20, <br />TYPE I - INORGANIC, COMPLYING WITH VOC LIMITATIONS OF <br />AUTHORITIES HAVING JURISDICTION. <br />2.02 FABRICATION <br />A. <br />FIT AND SHOP ASSEMBLE ITEMS IN LARGEST PRACTICAL SECTIONS, <br />FOR DELIVERY TO SITE. <br />B. <br />FABRICATE ITEMS WITH JOINTS TIGHTLY FITTED AND SECURED. <br />C. <br />CONTINUOUSLY SEAL JOINED MEMBERS BY CONTINUOUS WELDS OR <br />INTERMITENT WELDS AS INDICATED. <br />D. <br />GRIND EXPOSED JOINTS FLUSH AND SMOOTH WITH ADJACENT FINISH <br />SURFACE. MAKE EXPOSED JOINTS BUTT TIGHT, FLUSH, AND HAIRLINE. <br />EASE EXPOSED EDGES TO SMALL UNIFORM RADIUS. <br />E. <br />EXPOSED MECHANICAL FASTENINGS: FLUSH COUNTERSUNK SCREWS <br />OR BOLTS, UNOBTRUSIVELY LOCATED, CONSISTENT WITH DESIGN OF <br />COMPONENT, EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. <br />F. <br />SUPPLY COMPONENTS REQUIRED FOR ANCHORAGE OF <br />FABRICATIONS. FABRICATE ANCHORS AND RELATED COMPONENTS <br />OF SAME MATERIAL AND FINISH AS FABRICATION, EXCEPT WHERE <br />SPECIFICALLY NOTED OTHERWISE. <br />2.03 FABRICATED ITEMS <br />A. <br />LEDGE ANGLES, SHELF ANGLES, CHANNELS, AND PLATES NOT <br />ATTACHED TO STRUCTURAL FRAMING: FOR SUPPORT AND <br />ATTACHMENT OF INTERIOR SOFFIT AND MISC. CONSTRUCTION <br />INDICATED ON DRAWINGS, PRIME PAINT FINISH. <br />B. <br />LINTELS: AS DETAILED, GALVANIZED FINISH. <br />2.04 FINISHES - STEEL <br />A. <br />PRIME PAINT ALL STEEL ITEMS. <br />B. <br />PREPARE SURFACES TO BE PRIMED IN ACCORDANCE WITH SSPC-SP2. <br />C. <br />CLEAN SURFACES OF RUST, SCALE, GREASE, AND FOREIGN MATTER <br />PRIOR TO FINISHING. <br />D. <br />PRIME PAINTING: TWO COATS. <br />E. <br />GALVANIZING OF STRUCTURAL STEEL MEMBERS: GALVANIZE AFTER <br />FABRICATION TO ASTM A 123/A 123M REQUIREMENTS. PROVIDE <br />MINIMUM 1.7 OZ/SQ FT (530 G/SQ M) GALVANIZED COATING. <br />F. <br />GALVANIZING OF NON-STRUCTURAL ITEMS: GALVANIZE AFTER <br />FABRICATION TO ASTM A 123/A 123M REQUIREMENTS. <br />2.05 FABRICATION TOLERANCES <br />A. <br />SQUARENESS: 1/8 INCH (3 MM) MAXIMUM DIFFERENCE IN DIAGONAL <br />MEASUREMENTS. <br />B. <br />MAXIMUM OFFSET BETWEEN FACES: 1/16 INCH (1.5 MM). <br />C. <br />MAXIMUM MISALIGNMENT OF ADJACENT MEMBERS: 1/16 INCH (1.5 <br />MM). <br />D. <br />MAXIMUM BOW: V8 INCH (3 MM) IN 48 INCHES (1.2 M). <br />E. <br />MAXIMUM DEVIATION FROM PLANE: 1/16 INCH (1.5 MM) IN 48 INCHES <br />(1.2 M). <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />VERIFY THAT FIELD CONDITIONS ARE ACCEPTABLE AND ARE READY <br />TO RECEIVE WORK. <br />3.02 PREPARATION <br />A. <br />CLEAN AND STRIP PRIMED STEEL ITEMS TO BARE METAL WHERE SITE <br />WELDING IS REQUIRED. <br />B. <br />SUPPLY SETTING TEMPLATES TO THE APPROPRIATE ENTITIES FOR <br />STEEL ITEMS REQUIRED TO BE CAST INTO CONCRETE OR EMBEDDED <br />IN MASONRY. <br />3.03 INSTALLATION <br />A. <br />INSTALL ITEMS PLUMB AND LEVEL, ACCURATELY FITTED, FREE FROM <br />DISTORTION OR DEFECTS. <br />B. <br />PROVIDE FOR ERECTION LOADS, AND FOR SUFFICIENT TEMPORARY <br />BRACING TO MAINTAIN TRUE ALIGNMENT UNTIL COMPLETION OF <br />ERECTION AND INSTALLATION OF PERMANENT ATTACHMENTS. <br />C. <br />PERFORM FIELD WELDING IN ACCORDANCE WITH AWS 131.1. <br />D. <br />OBTAIN APPROVAL PRIOR TO SITE CUTTING OR MAKING <br />ADJUSTMENTS NOT SCHEDULED. <br />E. <br />AFTER ERECTION, PRIME WELDS, ABRASIONS, AND SURFACES NOT <br />SHOP PRIMED OR GALVANIZED, EXCEPT SURFACES TO BE IN <br />CONTACT WITH CONCRETE. <br />3.04 ERECTION TOLERANCES <br />A. <br />MAXIMUM VARIATION FROM PLUMB: 1/4 INCH (6 MM) PER STORY, <br />NON -CUMULATIVE. <br />B. <br />MAXIMUM OFFSET FROM TRUE ALIGNMENT: 1/4 INCH (6 MM). <br />C. <br />MAXIMUM OUT -OF -POSITION: 1/4 INCH (6 MM). <br />END OF SECTION <br />Z <br />0 <br />a <br />U <br />W <br />W <br />4 <br />0 <br />W <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />PROJECT MANAGER DESIGNER <br />SS SS <br />JOB NO. <br />18390 <br />AS1 m2 <br />