Laserfiche WebLink
SECTION 017300 - EXECUTION <br />PART 1 GENERAL <br />1.01 SUBMITTALS <br />A. <br />SEE SECTION 013000 -ADMINISTRATIVE REQUIREMENTS, FOR <br />3•04 <br />SUBMITTAL PROCEDURES. <br />B. <br />SURVEY WORK: SUBMIT NAME, ADDRESS, AND TELEPHONE NUMBER <br />OF SURVEYOR BEFORE STARTING SURVEY WORK. <br />1. ON REQUEST, SUBMIT DOCUMENTATION VERIFYING <br />ACCURACY OF SURVEY WORK. <br />2. SUBMIT A COPY OF SITE DRAWING SIGNED BY THE LAND <br />SURVEYOR THAT THE ELEVATIONS AND LOCATIONS OF THE <br />WORK ARE IN CONFORMANCE WITH CONTRACT DOCUMENTS. <br />3. SUBMIT SURVEYS AND SURVEY LOGS FOR THE PROJECT <br />RECORD. <br />C. <br />DEMOLITION PLAN: SUBMIT DEMOLITION PLAN AS SPECIFIED BY EPA, <br />OSHA AND GOVERNING AUTHORITIES. <br />1. INDICATE EXTENT OF DEMOLITION, REMOVAL SEQUENCE, <br />BRACING AND SHORING, AND LOCATION AND CONSTRUCTION <br />OF BARRICADES AND FENCES. <br />2. IDENTIFY DEMOLITION FIRM AND SUBMIT QUALIFICATIONS. <br />3. INCLUDE A SUMMARY OF SAFETY PROCEDURES. <br />4. INCLUDE SUMMARY OF DEMOLITION AND REMOVAL OF <br />ASBESTOS MATERIALS. <br />D. <br />CUTTING AND PATCHING: SUBMIT WRITTEN REQUEST IN ADVANCE OF <br />CUTTING OR ALTERATION, WHICH AFFECTS: <br />1. STRUCTURAL INTEGRITY OF ANY ELEMENT OF PROJECT. <br />2. INTEGRITY OF WEATHER EXPOSED OR MOISTURE RESISTANT <br />ELEMENT. <br />3. EFFICIENCY, MAINTENANCE, OR SAFETY OF ANY OPERATIONAL <br />ELEMENT. <br />4. VISUAL QUALITIES OF SIGHT EXPOSED ELEMENTS. <br />5. WORK OF THE OWNER OR SEPARATE CONTRACTOR. <br />E. <br />PROJECT RECORD DOCUMENTS: ACCURATELY RECORD ACTUAL <br />LOCATIONS OF CAPPED AND ACTIVE UTILITIES. <br />1.02 QUALIFICATIONS <br />A. <br />FOR SURVEY WORK, EMPLOY A LAND SURVEYOR REGISTERED IN AND <br />ACCEPTABLE TO THE OWNER. SUBMIT EVIDENCE OF SURVEYOR'S <br />ERRORS AND OMISSIONS INSURANCE COVERAGE IN THE FORM OF AN <br />INSURANCE CERTIFICATE. <br />1.03 PROJECT CONDITIONS <br />A. <br />PROTECT SITE FROM PUDDLING OR RUNNING WATER. PROVIDE <br />WATER BARRIERS AS REQUIRED TO PROTECT SITE FROM SOIL <br />EROSION. <br />B. <br />VENTILATE ENCLOSED AREAS TO ASSIST CURE OF MATERIALS, TO <br />DISSIPATE HUMIDITY, AND TO PREVENT ACCUMULATION OF DUST, <br />FUMES, VAPORS, OR GASES. <br />C. <br />DUST CONTROL: EXECUTE WORK BY METHODS TO MINIMIZE RAISING <br />DUST FROM CONSTRUCTION OPERATIONS. PROVIDE POSITIVE MEANS <br />TO PREVENT AIR -BORNE DUST FROM DISPERSING INTO ATMOSPHERE. <br />D. <br />EROSION AND SEDIMENT CONTROL: PLAN AND EXECUTE WORK BY <br />METHODS TO CONTROL SURFACE DRAINAGE FROM CUTS AND FILLS, <br />FROM BORROW AND WASTE DISPOSAL AREAS. PREVENT EROSION <br />AND SEDIMENTATION. <br />E. <br />PEST CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES TO <br />PREVENT PESTS AND INSECTS FROM DAMAGING THE WORK. <br />F. <br />RODENT CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES TO <br />PREVENT RODENTS FROM ACCESSING OR INVADING PREMISES. <br />G. <br />POLLUTION CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES <br />TO PREVENT CONTAMINATION OF SOIL, WATER, AND ATMOSPHERE <br />FROM DISCHARGE OF NOXIOUS, TOXIC SUBSTANCES, AND <br />POLLUTANTS PRODUCED BY CONSTRUCTION OPERATIONS. <br />1.04 COORDINATION <br />A. <br />COORDINATE SCHEDULING, SUBMITTALS, AND WORK OF THE VARIOUS <br />SECTIONS OF THE PROJECT MANUAL TO ENSURE EFFICIENT AND <br />ORDERLY SEQUENCE OF INSTALLATION OF INTERDEPENDENT <br />CONSTRUCTION ELEMENTS, WITH PROVISIONS FOR ACCOMMODATING <br />ITEMS INSTALLED LATER. <br />B. <br />NOTIFY AFFECTED UTILITY COMPANIES AND COMPLY WITH THEIR <br />REQUIREMENTS. <br />C. <br />VERIFY THAT UTILITY REQUIREMENTS AND CHARACTERISTICS OF NEW <br />OPERATING EQUIPMENT ARE COMPATIBLE WITH BUILDING UTILITIES. <br />COORDINATE WORK OF VARIOUS SECTIONS HAVING <br />INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTING <br />TO, AND PLACING IN SERVICE, SUCH EQUIPMENT. <br />D. <br />COORDINATE SPACE REQUIREMENTS, SUPPORTS, AND INSTALLATION <br />OF MECHANICAL AND ELECTRICAL WORK WHICH ARE INDICATED <br />DIAGRAMMATICALLY ON DRAWINGS. FOLLOW ROUTING SHOWN FOR <br />PIPES, DUCTS, AND CONDUIT, AS CLOSELY AS PRACTICABLE, PLACE <br />RUNS PARALLEL WITH LINES OF BUILDING. UTILIZE SPACES <br />EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER <br />3.05 <br />INSTALLATIONS, FOR MAINTENANCE, AND FOR REPAIRS. <br />E. <br />IN FINISHED AREAS EXCEPT AS OTHERWISE INDICATED, CONCEAL <br />PIPES, DUCTS, AND WIRING WITHIN THE CONSTRUCTION. <br />COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISH <br />ELEMENTS. <br />F. <br />COORDINATE COMPLETION AND CLEAN UP OF WORK OF SEPARATE <br />SECTIONS. <br />G. <br />AFTER THE OWNER OCCUPANCY OF PREMISES, COORDINATE ACCESS <br />TO SITE FOR CORRECTION OF DEFECTIVE WORK AND WORK NOT IN <br />ACCORDANCE WITH CONTRACT DOCUMENTS, TO MINIMIZE <br />DISRUPTION OF THE OWNER'S ACTIVITIES. <br />PART 2 PRODUCTS <br />2.01 PATCHING MATERIALS <br />A. <br />NEW MATERIALS: AS SPECIFIED IN PRODUCT SECTIONS, MATCH <br />EXISTING PRODUCTS AND WORK FOR PATCHING AND EXTENDING <br />WORK. <br />B. <br />TYPE AND QUALITY OF EXISTING PRODUCTS: DETERMINE BY <br />INSPECTING AND TESTING PRODUCTS WHERE NECESSARY, <br />REFERRING TO EXISTING WORK AS A STANDARD. <br />C. <br />PRODUCT SUBSTITUTION: FOR ANY PROPOSED CHANGE IN <br />MATERIALS, SUBMIT REQUEST FOR SUBSTITUTION DESCRIBED IN <br />SECTION 016000. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A. <br />VERIFY THAT EXISTING SITE CONDITIONS AND SUBSTRATE SURFACES <br />ARE ACCEPTABLE FOR SUBSEQUENT WORK. START OF WORK MEANS <br />ACCEPTANCE OF EXISTING CONDITIONS. <br />B. <br />VERIFY THAT EXISTING SUBSTRATE IS CAPABLE OF STRUCTURAL <br />SUPPORT OR ATTACHMENT OF NEW WORK BEING APPLIED OR <br />3.06 <br />ATTACHED. <br />C. <br />EXAMINE AND VERIFY SPECIFIC CONDITIONS DESCRIBED IN <br />INDIVIDUAL SPECIFICATION SECTIONS. <br />D. <br />TAKE FIELD MEASUREMENTS BEFORE CONFIRMING PRODUCT <br />ORDERS OR BEGINNING FABRICATION, TO MINIMIZE WASTE DUE TO <br />OVER -ORDERING OR MIS -FABRICATION. <br />E. <br />VERIFY THAT UTILITY SERVICES ARE AVAILABLE, OF THE CORRECT <br />CHARACTERISTICS, AND IN THE CORRECT LOCATIONS. <br />F. <br />PRIOR TO CUTTING: EXAMINE EXISTING CONDITIONS PRIOR TO <br />COMMENCING WORK, INCLUDING ELEMENTS SUBJECT TO DAMAGE OR <br />MOVEMENT DURING CUTTING AND PATCHING. AFTER UNCOVERING <br />3.07 <br />EXISTING WORK, ASSESS CONDITIONS AFFECTING PERFORMANCE OF <br />WORK. BEGINNING OF CUTTING OR PATCHING MEANS ACCEPTANCE <br />OF EXISTING CONDITIONS. <br />3.02 PREPARATION <br />A. <br />CLEAN SUBSTRATE SURFACES PRIOR TO APPLYING NEXT MATERIAL <br />OR SUBSTANCE. <br />B. <br />SEAL CRACKS OR OPENINGS OF SUBSTRATE PRIOR TO APPLYING <br />NEXT MATERIAL OR SUBSTANCE. <br />C. <br />APPLY MANUFACTURER REQUIRED OR RECOMMENDED SUBSTRATE <br />PRIMER, SEALER, OR CONDITIONER PRIOR TO APPLYING ANY NEW <br />MATERIAL OR SUBSTANCE IN CONTACT OR BOND. <br />3.03 GENERAL <br />INSTALLATION REQUIREMENTS <br />A. <br />INSTALL PRODUCTS AS SPECIFIED IN INDIVIDUAL SECTIONS, IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND <br />RECOMMENDATIONS, AND SO AS TO AVOID WASTE DUE TO <br />NECESSITY FOR REPLACEMENT. <br />B. <br />MAKE VERTICAL ELEMENTS PLUMB AND HORIZONTAL ELEMENTS <br />LEVEL, UNLESS OTHERWISE INDICATED. <br />C. <br />INSTALL EQUIPMENT AND FITTINGS PLUMB AND LEVEL, NEATLY <br />3.08 <br />ALIGNED WITH ADJACENT VERTICAL AND HORIZONTAL LINES, UNLESS <br />OTHERWISE INDICATED. <br />D. MAKE CONSISTENT TEXTURE ON SURFACES, WITH SEAMLESS <br />TRANSITIONS, UNLESS OTHERWISE INDICATED. <br />E. MAKE NEAT TRANSITIONS BETWEEN DIFFERENT SURFACES, <br />MAINTAINING TEXTURE AND APPEARANCE. <br />ALTERATIONS <br />A. DRAWINGS SHOWING EXISTING CONSTRUCTION AND UTILITIES ARE <br />BASED ON EXISTING RECORD DOCUMENTS ONLY, EXISTING <br />CONSTRUCTION CONDITIONS HAVE NOT BEEN FIELD VERIFIED. <br />1. VERIFY THAT CONSTRUCTION AND UTILITY ARRANGEMENTS <br />ARE AS SHOWN. <br />2. REPORT DISCREPANCIES TO THE ARCHITECTS BEFORE <br />DISTURBING EXISTING INSTALLATION. <br />3. BEGINNING OF ALTERATIONS WORK CONSTITUTES <br />ACCEPTANCE OF EXISTING CONDITIONS. <br />B. MAINTAIN WEATHERPROOF EXTERIOR BUILDING ENCLOSURE EXCEPT <br />FOR INTERRUPTIONS REQUIRED FOR REPLACEMENT OR <br />MODIFICATIONS, TAKE CARE TO PREVENT WATER AND HUMIDITY <br />DAMAGE. <br />1. WHERE OPENINGS IN EXTERIOR ENCLOSURE EXIST, PROVIDE <br />CONSTRUCTION TO MAKE EXTERIOR ENCLOSURE <br />WEATHERPROOF. <br />2. INSULATE EXISTING DUCTS OR PIPES THAT ARE EXPOSED TO <br />OUTDOOR AMBIENT TEMPERATURES BY ALTERATIONS WORK. <br />C. REMOVE EXISTING WORK AS INDICATED AND AS REQUIRED TO <br />ACCOMPLISH NEW WORK. <br />1. REMOVE ROTTED WOOD, CORRODED METALS, AND <br />DETERIORATED MASONRY AND CONCRETE, REPLACE WITH <br />NEW CONSTRUCTION SPECIFIED. <br />2. REMOVE ITEMS INDICATED ON DRAWINGS. <br />3. RELOCATE ITEMS INDICATED ON DRAWINGS. <br />4. WHERE NEW SURFACE FINISHES ARE TO BE APPLIED TO <br />EXISTING WORK, PERFORM REMOVALS, PATCH, AND PREPARE <br />EXISTING SURFACES AS REQUIRED TO RECEIVE NEW FINISH, <br />REMOVE EXISTING FINISH IF NECESSARY FOR SUCCESSFUL <br />APPLICATION OF NEW FINISH. <br />5. WHERE NEW SURFACE FINISHES ARE NOT SPECIFIED OR <br />INDICATED, PATCH HOLES AND DAMAGED SURFACES TO <br />MATCH ADJACENT FINISHED SURFACES AS CLOSELY AS <br />POSSIBLE. <br />D. SERVICES (INCLUDING BUT NOT LIMITED TO HVAC, PLUMBING, <br />ELECTRICAL, AND TELECOMMUNICATIONS): REMOVE, RELOCATE, AND <br />EXTEND EXISTING SYSTEMS TO ACCOMMODATE NEW CONSTRUCTION. <br />1. MAINTAIN EXISTING ACTIVE SYSTEMS THAT ARE TO REMAIN IN <br />OPERATION, MAINTAIN ACCESS TO EQUIPMENT AND <br />OPERATIONAL COMPONENTS, IF NECESSARY, MODIFY <br />INSTALLATION TO ALLOW ACCESS OR PROVIDE ACCESS PANEL. <br />2. WHERE EXISTING SYSTEMS OR EQUIPMENT ARE NOT ACTIVE <br />AND CONTRACT DOCUMENTS REQUIRE REACTIVATION, PUT <br />BACK INTO OPERATIONAL CONDITION, REPAIR SUPPLY, <br />DISTRIBUTION, AND EQUIPMENT AS REQUIRED. <br />3. WHERE EXISTING ACTIVE SYSTEMS SERVE OCCUPIED <br />FACILITIES BUT ARE TO BE REPLACED WITH NEW SERVICES, <br />MAINTAIN EXISTING SYSTEMS IN SERVICE UNTIL NEW SYSTEMS <br />ARE COMPLETE AND READY FOR SERVICE. <br />a. DISABLE EXISTING SYSTEMS ONLY TO MAKE <br />SWITCHOVERS AND CONNECTIONS, MINIMIZE DURATION <br />OF OUTAGES. <br />b. PROVIDE TEMPORARY CONNECTIONS AS REQUIRED TO <br />MAINTAIN EXISTING SYSTEMS IN SERVICE. <br />4. VERIFY THAT ABANDONED SERVICES SERVE ONLY <br />ABANDONED FACILITIES. <br />5. REMOVE ABANDONED PIPE, DUCTS, CONDUITS, AND <br />EQUIPMENT, REMOVE BACK TO SOURCE OF SUPPLY WHERE <br />POSSIBLE, OTHERWISE CAP STUB AND TAG WITH <br />IDENTIFICATION, PATCH HOLES LEFT BY REMOVAL USING <br />MATERIALS SPECIFIED FOR NEW CONSTRUCTION. <br />E. PROTECT EXISTING WORK TO REMAIN. <br />1. PREVENT MOVEMENT OF STRUCTURE, PROVIDE SHORING AND <br />BRACING IF NECESSARY. <br />2. PERFORM CUTTING TO ACCOMPLISH REMOVALS NEATLY AND <br />AS SPECIFIED FOR CUTTING NEW WORK. <br />3. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED <br />DURING REMOVAL WORK. <br />4. PATCH AS SPECIFIED FOR PATCHING NEW WORK. <br />F. ADAPT EXISTING WORK TO FIT NEW WORK: <br />1. WHEN EXISTING FINISHED SURFACES ARE CUT SO THAT A <br />SMOOTH TRANSITION WITH NEW WORK IS NOT POSSIBLE, <br />TERMINATE EXISTING SURFACE ALONG A STRAIGHT LINE AT A <br />NATURAL LINE OF DIVISION AND MAKE RECOMMENDATION TO <br />THE ARCHITECTS. <br />CUTTING AND PATCHING <br />A. EXECUTE CUTTING AND PATCHING INCLUDING EXCAVATION AND FILL <br />TO COMPLETE THE WORK TO UNCOVER WORK IN ORDE <br />R TO INSTALL <br />IMPROPERLY SEQUENCED WORK, TO REMOVE AND REPLACE <br />DEFECTIVE OR NON -CONFORMING WORK, TO REMOVE SAMPLES OF <br />INSTALLED WORK FOR TESTING WHEN REQUESTED, TO PROVIDE <br />OPENINGS IN THE WORK FOR PENETRATION OF MECHANICAL AND <br />ELECTRICAL WORK, TO EXECUTE PATCHING TO COMPLEMENT <br />ADJACENT WORK, AND TO FIT PRODUCTS TOGETHER TO INTEGRATE <br />WITH OTHER WORK. <br />B. EXECUTE WORK BY METHODS TO AVOID DAMAGE TO OTHER WORK, <br />AND WHICH WILL PROVIDE APPROPRIATE SURFACES TO RECEIVE <br />PATCHING AND FINISHING. IN EXISTING WORK, MINIMIZE DAMAGE AND <br />RESTORE TO ORIGINAL CONDITION. <br />C. EMPLOY ORIGINAL INSTALLER TO PERFORM CUTTING FOR WEATHER <br />EXPOSED AND MOISTURE RESISTANT ELEMENTS, AND SIGHT <br />EXPOSED SURFACES. <br />D. CUT RIGID MATERIALS USING MASONRY SAW OR CORE DRILL. <br />PNEUMATIC TOOLS NOT ALLOWED WITHOUT PRIOR APPROVAL. <br />E. RESTORE WORK WITH NEW PRODUCTS IN ACCORDANCE WITH <br />REQUIREMENTS OF CONTRACT DOCUMENTS. <br />F. FIT WORK AIR TIGHT TO PIPES, SLEEVES, DUCTS, CONDUIT, AND <br />OTHER PENETRATIONS THROUGH SURFACES. <br />G. REFINISH SURFACES TO MATCH ADJACENT FINISH. FOR CONTINUOUS <br />SURFACES, REFINISH TO NEAREST INTERSECTION OR NATURAL <br />BREAK. FOR AN ASSEMBLY, REFINISH ENTIRE UNIT. <br />H. MAKE NEAT TRANSITIONS. PATCH WORK TO MATCH ADJACENT WORK <br />IN TEXTURE AND APPEARANCE. WHERE NEW WORK ABUTS OR <br />ALIGNS WITH EXISTING, PERFORM A SMOOTH AND EVEN TRANSITION. <br />PROGRESS CLEANING <br />A. MAINTAIN AREAS FREE OF WASTE MATERIALS, DEBRIS, AND RUBBISH. <br />MAINTAIN SITE IN A CLEAN AND ORDERLY CONDITION. <br />B. REMOVE DEBRIS AND RUBBISH FROM PIPE CHASES, PLENUMS, <br />ATTICS, CRAWL SPACES, AND OTHER CLOSED OR REMOTE SPACES, <br />PRIOR TO ENCLOSING THE SPACE. <br />C. BROOM AND VACUUM CLEAN INTERIOR AREAS PRIOR TO START OF <br />SURFACE FINISHING, AND CONTINUE CLEANING TO ELIMINATE DUST. <br />D. COLLECT AND REMOVE WASTE MATERIALS, DEBRIS, AND <br />TRASH/RUBBISH FROM SITE PERIODICALLY AND DISPOSE OFF -SITE, <br />DO NOT BURN OR BURY. <br />PROTECTION OF INSTALLED WORK <br />A. PROTECT INSTALLED WORK FROM DAMAGE BY CONSTRUCTION <br />OPERATIONS. <br />B. PROVIDE SPECIAL PROTECTION WHERE SPECIFIED IN INDIVIDUAL <br />SPECIFICATION SECTIONS. <br />C. PROVIDE TEMPORARY AND REMOVABLE PROTECTION FOR INSTALLED <br />PRODUCTS. CONTROL ACTIVITY IN IMMEDIATE WORK AREA TO <br />PREVENT DAMAGE. <br />D. PROVIDE PROTECTIVE COVERINGS AT WALLS, PROJECTIONS, JAMBS, <br />SILLS, AND SOFFITS OF OPENINGS. <br />E. PROTECT FINISHED FLOORS, STAIRS, AND OTHER SURFACES FROM <br />TRAFFIC, DIRT, WEAR, DAMAGE, OR MOVEMENT OF HEAVY OBJECTS, <br />BY PROTECTING WITH DURABLE SHEET MATERIALS. <br />F. PROHIBIT TRAFFIC OR STORAGE UPON WATERPROOFED OR ROOFED <br />SURFACES. IF TRAFFIC OR ACTIVITY IS NECESSARY, OBTAIN <br />RECOMMENDATIONS FOR PROTECTION FROM WATERPROOFING OR <br />ROOFING MATERIAL MANUFACTURER. <br />G. REMOVE PROTECTIVE COVERINGS WHEN NO LONGER NEEDED, <br />REUSE OR RECYCLE PLASTIC COVERINGS IF POSSIBLE. <br />STARTING SYSTEMS <br />A. COORDINATE SCHEDULE FOR START-UP OF VARIOUS EQUIPMENT AND <br />SYSTEMS. <br />B. <br />VERIFY THAT EACH PIECE OF EQUIPMENT OR SYSTEM HAS BEEN <br />CHECKED FOR PROPER LUBRICATION, DRIVE ROTATION, BELT <br />TENSION, CONTROL SEQUENCE, AND FOR CONDITIONS WHICH MAY <br />CAUSE DAMAGE. <br />C. <br />VERIFY TESTS, METER READINGS, AND SPECIFIED ELECTRICAL <br />CHARACTERISTICS AGREE WITH THOSE REQUIRED BY THE <br />EQUIPMENT OR SYSTEM MANUFACTURER. <br />D. <br />VERIFY THAT WIRING AND SUPPORT COMPONENTS FOR EQUIPMENT <br />ARE COMPLETE AND TESTED. <br />E. <br />EXECUTE START-UP UNDER SUPERVISION OF APPLICABLE <br />PERSONNEL AND MANUFACTURER'S REPRESENTATIVE IN <br />ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS. <br />F. <br />SUBMIT A WRITTEN REPORT THAT EQUIPMENT OR SYSTEM HAS BEEN <br />PROPERLY INSTALLED AND IS FUNCTIONING CORRECTLY. <br />3.09 DEMONSTRATION AND INSTRUCTION <br />A. <br />DEMONSTRATE START-UP, OPERATION, CONTROL, ADJUSTMENT, <br />TROUBLE -SHOOTING, SERVICING, MAINTENANCE, AND SHUTDOWN OF <br />EACH ITEM OF EQUIPMENT AT SCHEDULED TIME, AT EQUIPMENT <br />LOCATION. <br />B. <br />FOR EQUIPMENT OR SYSTEMS REQUIRING SEASONAL OPERATION, <br />PERFORM DEMONSTRATION FOR OTHER SEASON WITHIN SIX MONTHS. <br />C. <br />PROVIDE A QUALIFIED PERSON WHO IS KNOWLEDGEABLE ABOUT THE <br />PROJECT TO PERFORM DEMONSTRATION AND INSTRUCTION OF <br />OWNER PERSONNEL. <br />3.10 ADJUSTING <br />A. <br />ADJUST OPERATING PRODUCTS AND EQUIPMENT TO ENSURE <br />SMOOTH AND UNHINDERED OPERATION. <br />3.11 FINAL CLEANING <br />A. <br />EXECUTE FINAL CLEAN UP PRIOR TO SUBSTANTIAL COMPLETION. <br />CLEANUP SHALL INCLUDE BUILDING AREA, CONSTRUCTION AREA <br />WITHIN WORK LIMITS AND CONSTRUCTION ACCESS ROUTES. <br />B. <br />USE CLEANING MATERIALS THAT ARE NON -HAZARDOUS. <br />C. <br />CLEAN INTERIOR AND EXTERIOR GLASS, SURFACES EXPOSED TO <br />VIEW, REMOVE TEMPORARY LABELS, STAINS AND FOREIGN <br />SUBSTANCES, POLISH TRANSPARENT AND GLOSSY SURFACES, WIPE <br />GYPSUM BOARD WALLS READY FOR TENANT PAINT FINISH, BROOM <br />CLEAN INTERIOR FLOOR SLAB <br />D. <br />CLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH <br />CLEANING MATERIALS APPROPRIATE TO THE SURFACE AND MATERIAL <br />BEING CLEANED. <br />E. <br />CLEAN FILTERS OF OPERATING EQUIPMENT. <br />F. <br />CLEAN DEBRIS FROM ROOFS, DOWNSPOUTS, AND DRAINAGE <br />SYSTEMS. <br />G. <br />CLEAN SITE, SWEEP PAVED AREAS, RAKE CLEAN LANDSCAPED <br />SURFACES. <br />H. <br />REMOVE WASTE, SURPLUS MATERIALS, TRASH/RUBBISH, AND <br />CONSTRUCTION FACILITIES FROM THE SITE, DISPOSE OF IN LEGAL <br />MANNER, DO NOT BURN OR BURY. <br />3.12 CLOSEOUT PROCEDURES <br />A. <br />MAKE SUBMITTALS THAT ARE REQUIRED BY GOVERNING OR OTHER <br />AUTHORITIES. <br />1. PROVIDE COPIES TO THE ARCHITECTS AND THE OWNER. <br />B. <br />NOTIFY THE ARCHITECTS AND THE OWNER WHEN WORK IS <br />CONSIDERED READY FOR SUBSTANTIAL COMPLETION. <br />C. <br />SUBMIT WRITTEN CERTIFICATION THAT CONTRACT DOCUMENTS HAVE <br />BEEN REVIEWED, WORK HAS BEEN INSPECTED, AND THAT WORK IS <br />COMPLETE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND <br />READY FOR THE ARCHITECTS'S AND THE OWNER'S REVIEW. <br />D. <br />CORRECT ITEMS OF WORK LISTED IN EXECUTED CERTIFICATES OF <br />SUBSTANTIAL COMPLETION AND COMPLY WITH REQUIREMENTS FOR <br />ACCESS TO THE OWNER -OCCUPIED AREAS. <br />E. <br />NOTIFY THE ARCHITECTS AND THE OWNER WHEN WORK IS <br />CONSIDERED FINALLY COMPLETE. <br />F. <br />COMPLETE ITEMS OF WORK DETERMINED BY THE ARCHITECTS'S AND <br />THE OWNER'S FINAL INSPECTION. <br />END OF SECTION <br />SECTION 017700 - CLOSEOUT SUBMITTALS <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. <br />PROJECT RECORD DOCUMENTS. <br />B. <br />OPERATION AND MAINTENANCE DATA. <br />C. <br />WARRANTIES AND BONDS. <br />1.02 RELATED SECTIONS <br />A. <br />SECTION 013000 - ADMINISTRATIVE REQUIREMENTS: SUBMITTALS <br />PROCEDURES, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. <br />B. <br />INDIVIDUAL PRODUCT SECTIONS: SPECIFIC REQUIREMENTS FOR <br />OPERATION AND MAINTENANCE DATA. <br />C. <br />INDIVIDUAL PRODUCT SECTIONS: WARRANTIES REQUIRED FOR <br />SPECIFIC PRODUCTS OR WORK. <br />1.03 SUBMITTALS <br />A. <br />PROJECT RECORD DOCUMENTS: SUBMIT DOCUMENTS TO THE <br />ARCHITECTS WITH CLAIM FOR FINAL APPLICATION FOR PAYMENT. <br />B. <br />OPERATION AND MAINTENANCE DATA: <br />1. SUBMIT TWO COPIES OF PRELIMINARY DRAFT OR PROPOSED <br />FORMATS AND OUTLINES OF CONTENTS BEFORE START OF <br />WORK. THE ARCHITECTS WILL REVIEW DRAFT AND RETURN <br />ONE COPY WITH COMMENTS. <br />2. SUBMIT 1 COPY OF COMPLETED DOCUMENTS 15 DAYS PRIOR <br />TO FINAL INSPECTION. THIS COPY WILL BE REVIEWED AND <br />RETURNED AFTER FINAL INSPECTION, WITH THE ARCHITECTS <br />COMMENTS. REVISE CONTENT OF ALL DOCUMENT SETS AS <br />REQUIRED PRIOR TO FINAL SUBMISSION. <br />3. SUBMIT TWO SETS OF REVISED FINAL DOCUMENTS IN FINAL <br />FORM WITHIN 10 DAYS AFTER FINAL INSPECTION. <br />C. <br />WARRANTIES AND BONDS: <br />1. FOR EQUIPMENT OR COMPONENT PARTS OF EQUIPMENT PUT <br />INTO SERVICE DURING CONSTRUCTION WITH THE OWNER'S <br />PERMISSION, SUBMIT DOCUMENTS WITHIN TEN DAYS AFTER <br />ACCEPTANCE. <br />2. MAKE OTHER SUBMITTALS WITHIN TEN DAYS AFTER DATE OF <br />SUBSTANTIAL COMPLETION, PRIOR TO FINAL APPLICATION FOR <br />PAYMENT. <br />3. FOR ITEMS OF WORK FOR WHICH ACCEPTANCE IS DELAYED <br />BEYOND DATE OF SUBSTANTIAL COMPLETION, SUBMIT WITHIN <br />TEN DAYS AFTER ACCEPTANCE, LISTING THE DATE OF <br />ACCEPTANCE AS THE BEGINNING OF THE WARRANTY PERIOD. <br />PART 3 EXECUTION <br />3.01 PROJECT RECORD DOCUMENTS <br />A. <br />MAINTAIN ON SITE ONE SET OF THE FOLLOWING RECORD <br />DOCUMENTS, RECORD ACTUAL REVISIONS TO THE WORK: <br />1. DRAWINGS. <br />2. SPECIFICATIONS. <br />3. ADDENDA. <br />4. CHANGE ORDERS AND OTHER MODIFICATIONS TO THE <br />CONTRACT. <br />5. REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. <br />6. MANUFACTURER'S INSTRUCTION FOR ASSEMBLY, <br />INSTALLATION, AND ADJUSTING. <br />B. <br />ENSURE ENTRIES ARE COMPLETE AND ACCURATE, ENABLING FUTURE <br />REFERENCE BY THE OWNER. <br />C. <br />STORE RECORD DOCUMENTS SEPARATE FROM DOCUMENTS USED <br />FOR CONSTRUCTION. <br />D. <br />RECORD INFORMATION CONCURRENT WITH CONSTRUCTION <br />PROGRESS. <br />E. <br />SPECIFICATIONS: LEGIBLY MARK AND RECORD AT EACH PRODUCT <br />SECTION DESCRIPTION OF ACTUAL PRODUCTS INSTALLED, INCLUDING <br />THE FOLLOWING: <br />1. MANUFACTURER'S NAME AND PRODUCT MODEL AND NUMBER. <br />2. PRODUCT SUBSTITUTIONS OR ALTERNATES UTILIZED. <br />3. CHANGES MADE BY ADDENDA AND MODIFICATIONS. <br />F. <br />RECORD DRAWINGS AND SHOP DRAWINGS: LEGIBLY MARK EACH ITEM <br />TO RECORD ACTUAL CONSTRUCTION INCLUDING: <br />1. MEASURED DEPTHS OF FOUNDATIONS IN RELATION TO FINISH <br />FIRST FLOOR DATUM. <br />2. MEASURED HORIZONTAL AND VERTICAL LOCATIONS OF <br />UNDERGROUND UTILITIES AND APPURTENANCES, <br />REFERENCED TO PERMANENT SURFACE IMPROVEMENTS. <br />3. MEASURED LOCATIONS OF INTERNAL UTILITIES AND <br />APPURTENANCES CONCEALED IN CONSTRUCTION, <br />REFERENCED TO VISIBLE AND ACCESSIBLE FEATURES OF THE <br />WORK. <br />4. FIELD CHANGES OF DIMENSION AND DETAIL. <br />5. DETAILS NOT ON ORIGINAL CONTRACT DRAWINGS. <br />3.02 OPERATION AND MAINTENANCE DATA <br />A. <br />FOR EACH PRODUCT OR SYSTEM: LIST NAMES, ADDRESSES AND <br />TELEPHONE NUMBERS OF SUBCONTRACTORS AND SUPPLIERS, <br />INCLUDING LOCAL SOURCE OF SUPPLIES AND REPLACEMENT PARTS. <br />B. <br />TYPED TEXT: AS REQUIRED TO SUPPLEMENT PRODUCT DATA. <br />PROVIDE LOGICAL SEQUENCE OF INSTRUCTIONS FOR EACH <br />PROCEDURE, INCORPORATING MANUFACTURER'S INSTRUCTIONS. <br />3.03 OPERATION AND MAINTENANCE DATA FOR EQUIPMENT AND SYSTEMS <br />A. <br />FOR EACH ITEM OF EQUIPMENT AND EACH SYSTEM: <br />1. DESCRIPTION OF UNIT OR SYSTEM, AND COMPONENT PARTS. <br />2. IDENTIFY FUNCTION, NORMAL OPERATING CHARACTERISTICS, <br />AND LIMITING CONDITIONS. <br />3. INCLUDE PERFORMANCE CURVES, WITH ENGINEERING DATA <br />AND TESTS. <br />4. COMPLETE NOMENCLATURE AND MODEL NUMBER OF <br />REPLACEABLE PARTS. <br />B. <br />OPERATING PROCEDURES: INCLUDE START-UP, BREAK-IN, AND <br />ROUTINE NORMAL OPERATING INSTRUCTIONS AND SEQUENCES. <br />INCLUDE REGULATION, CONTROL, STOPPING, SHUT -DOWN, AND <br />EMERGENCY INSTRUCTIONS. INCLUDE SUMMER, WINTER, AND ANY <br />SPECIAL OPERATING INSTRUCTIONS. <br />C. <br />MAINTENANCE REQUIREMENTS: INCLUDE ROUTINE PROCEDURES <br />AND GUIDE FOR PREVENTATIVE MAINTENANCE AND TROUBLE <br />SHOOTING, DISASSEMBLY, REPAIR, AND REASSEMBLY INSTRUCTIONS, <br />AND ALIGNMENT, ADJUSTING, BALANCING, AND CHECKING <br />INSTRUCTIONS. <br />D. <br />PROVIDE SERVICING AND LUBRICATION SCHEDULE, AND LIST OF <br />LUBRICANTS REQUIRED. <br />E. <br />INCLUDE MANUFACTURER'S PRINTED OPERATION AND MAINTENANCE <br />INSTRUCTIONS. <br />F. <br />INCLUDE SEQUENCE OF OPERATION BY CONTROLS MANUFACTURER. <br />G. <br />PROVIDE ORIGINAL MANUFACTURER'S PARTS LIST, ILLUSTRATIONS, <br />ASSEMBLY DRAWINGS, AND DIAGRAMS REQUIRED FOR MAINTENANCE. <br />H. <br />ADDITIONAL REQUIREMENTS: AS SPECIFIED IN INDIVIDUAL PRODUCT <br />SPECIFICATION SECTIONS. <br />3.04 OPERATION AND MAINTENANCE MANUALS <br />A. <br />PREPARE INSTRUCTIONS AND DATA BY PERSONNEL EXPERIENCED IN <br />MAINTENANCE AND OPERATION OF DESCRIBED PRODUCTS. <br />B. <br />PREPARE DATA IN THE FORM OF AN INSTRUCTIONAL MANUAL. <br />C. <br />BINDERS: COMMERCIAL QUALITY, 8-1/2 X 11 INCH (216 X 280 MM) <br />THREE D SIDE RING BINDERS WITH DURABLE PLASTIC COVERS, 2 INCH <br />(50 MM) MAXIMUM RING SIZE. WHEN MULTIPLE BINDERS ARE USED, <br />CORRELATE DATA INTO RELATED CONSISTENT GROUPINGS. , <br />D. <br />PROVIDE TABBED DIVIDERS FOR EACH SEPARATE PRODUCT AND <br />SYSTEM, WITH TYPED DESCRIPTION OF PRODUCT AND MAJOR <br />COMPONENT PARTS OF EQUIPMENT. <br />3.05 WARRANTIES AND BONDS <br />A. <br />OBTAIN WARRANTIES AND BONDS, EXECUTED IN DUPLICATE BY <br />RESPONSIBLE SUBCONTRACTORS, SUPPLIERS, AND <br />MANUFACTURERS, WITHIN TEN DAYS AFTER COMPLETION OF THE <br />APPLICABLE ITEM OF WORK. EXCEPT FOR ITEMS PUT INTO USE WITH <br />THE OWNER'S PERMISSION, LEAVE DATE OF BEGINNING OF TIME OF <br />WARRANTY UNTIL THE DATE OF SUBSTANTIAL COMPLETION IS <br />DETERMINED. <br />B. <br />VERIFY THAT DOCUMENTS ARE IN PROPER FORM, CONTAIN FULL <br />INFORMATION, AND ARE NOTARIZED. <br />C. <br />CO -EXECUTE SUBMITTALS WHEN REQUIRED. <br />D. <br />RETAIN WARRANTIES AND BONDS UNTIL TIME SPECIFIED FOR <br />SUBMITTAL. <br />END OF SECTION <br />SECTION 022000 - SITE PREPARATION <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. BUILDING DEMOLITION. <br />B. SELECTIVE DEMOLITION OF BUILT SITE ELEMENTS. <br />C. ABANDONMENT AND REMOVAL OF EXISTING UTILITIES AND UTILITY <br />STRUCTURES. <br />1.02 REFERENCES <br />A. 29 CFR 1926 - U.S. OCCUPATIONAL SAFETY AND HEALTH STANDARDS, <br />CURRENT EDITION. <br />B. NFPA 241 - STANDARD FOR SAFEGUARDING CONSTRUCTION, <br />ALTERATION, AND DEMOLITION OPERATIONS, 2000. <br />1.03 SUBMITTALS <br />A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR <br />SUBMITTAL PROCEDURES. <br />B. PROJECT RECORD DOCUMENTS: ACCURATELY RECORD ACTUAL <br />LOCATIONS OF CAPPED AND ACTIVE UTILITIES AND SUBSURFACE <br />CONSTRUCTION. <br />1.04 PROJECT CONDITIONS <br />A. MINIMIZE PRODUCTION OF DUST DUE TO DEMOLITION OPERATIONS, <br />DO NOT USE WATER IF THAT WILL RESULT IN ICE, FLOODING, <br />SEDIMENTATION OF PUBLIC WATERWAYS OR STORM SEWERS, OR <br />OTHER POLLUTION. <br />B. COMPLY WITH OTHER REQUIREMENTS SPECIFIED IN SECTION 017300. <br />PART 2 PRODUCTS <br />2.01 MATERIALS <br />A. FILL MATERIAL: AS SPECIFIED IN SECTION 02315 -FILL AND BACKFILL <br />PART 3 EXECUTION <br />3.01 EXISTING UTILITIES <br />A. COORDINATE WORK WITH UTILITY COMPANIES, NOTIFY BEFORE <br />STARTING WORK AND COMPLY WITH THEIR REQUIREMENTS, OBTAIN <br />REQUIRED PERMITS. <br />B. PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE. <br />C. DO NOT DISRUPT PUBLIC UTILITIES WITHOUT PERMIT FROM <br />AUTHORITY HAVING JURISDICTION. <br />D. DO NOT CLOSE, SHUT OFF, OR DISRUPT EXISTING LIFE SAFETY <br />SYSTEMS THAT ARE IN USE WITHOUT PRIOR WRITTEN NOTIFICATION <br />TO THE OWNER. <br />E. DO NOT CLOSE, SHUT OFF, OR DISRUPT EXISTING UTILITY BRANCHES <br />OR TAKE -OFFS THAT ARE IN USE WITHOUT PRIOR WRITTEN <br />NOTIFICATION TO THE OWNER. <br />F. LOCATE AND MARK UTILITIES TO REMAIN, MARK USING HIGHLY <br />VISIBLE TAGS OR FLAGS, WITH IDENTIFICATION OF UTILITY TYPE, <br />PROTECT FROM DAMAGE DUE TO SUBSEQUENT CONSTRUCTION, <br />USING SUBSTANTIAL BARRICADES IF NECESSARY. <br />G. REMOVE EXPOSED PIPING, VALVES, METERS, EQUIPMENT, SUPPORTS, <br />AND FOUNDATIONS OF DISCONNECTED AND ABANDONED UTILITIES. <br />H. PREPARE BUILDING DEMOLITION AREAS BY DISCONNECTING AND <br />CAPPING UTILITIES OUTSIDE THE DEMOLITION ZONE, IDENTIFY AND <br />MARK UTILITIES TO BE SUBSEQUENTLY RECONNECTED, IN SAME <br />MANNER AS OTHER UTILITIES TO REMAIN. <br />3.02 EXISTING BUILT ELEMENTS <br />A. SCOPE: <br />1. REMOVE THE BUILDING CONSTRUCTION WHERE REQUIRED TO <br />ACCOMMODATE NEW BUILDING CONSTRUCTION. <br />2. REMOVE OTHER ITEMS INDICATED, FOR SALVAGE AND REUSE <br />AND REINSTALLATION. <br />3. FILL EXCAVATIONS, OPEN PITS, AND HOLES IN GROUND AREAS <br />GENERATED AS RESULT OF REMOVALS, USING SPECIFIED FILL, <br />COMPACT FILL AS REQUIRED SO THAT REQUIRED ROUGH <br />GRADE ELEVATIONS DO NOT SUBSIDE WITHIN ONE YEAR <br />AFTER COMPLETION. <br />B. COMPLY WITH APPLICABLE CODES AND REGULATIONS FOR <br />DEMOLITION OPERATIONS AND SAFETY OF ADJACENT STRUCTURES <br />AND THE PUBLIC. <br />1. OBTAIN REQUIRED PERMITS. <br />2. COMPLY WITH APPLICABLE REQUIREMENTS OF NFPA 241. <br />3. USE OF EXPLOSIVES IS NOT PERMITTED. <br />4. TAKE PRECAUTIONS TO PREVENT CATASTROPHIC OR <br />UNCONTROLLED COLLAPSE OF STRUCTURES TO BE REMOVED, <br />DO NOT ALLOW WORKER OR PUBLIC ACCESS WITHIN RANGE <br />OF POTENTIAL COLLAPSE OF UNSTABLE STRUCTURES. <br />5. PROVIDE, ERECT, AND MAINTAIN TEMPORARY BARRIERS AND <br />SECURITY DEVICES. <br />6. USE PHYSICAL BARRIERS TO PREVENT ACCESS TO AREAS <br />THAT COULD BE HAZARDOUS TO WORKERS OR THE PUBLIC. <br />7. CONDUCT OPERATIONS TO MINIMIZE EFFECTS ON AND <br />INTERFERENCE WITH ADJACENT STRUCTURES AND <br />OCCUPANTS. <br />8. DO NOT CLOSE OR OBSTRUCT ROADWAYS OR SIDEWALKS <br />WITHOUT PERMIT. <br />9. CONDUCT OPERATIONS TO MINIMIZE OBSTRUCTION OF PUBLIC <br />AND PRIVATE ENTRANCES AND EXITS, DO NOT OBSTRUCT <br />REQUIRED EXITS AT ANY TIME, PROTECT PERSONS USING <br />ENTRANCES AND EXITS FROM REMOVAL OPERATIONS. <br />10. OBTAIN WRITTEN PERMISSION FROM OWNERS OF ADJACENT <br />PROPERTIES WHEN DEMOLITION EQUIPMENT WILL TRAVERSE, <br />INFRINGE UPON OR LIMIT ACCESS TO THEIR PROPERTY. <br />C. <br />PROTECT EXISTING STRUCTURES AND OTHER ELEMENTS THAT ARE <br />NOT TO BE REMOVED. <br />1. PROVIDE BRACING AND SHORING. <br />2. PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT <br />STRUCTURES. <br />3. STOP WORK IMMEDIATELY IF ADJACENT STRUCTURES APPEAR <br />TO BE IN DANGER. <br />D. <br />IF HAZARDOUS MATERIALS ARE DISCOVERED DURING REMOVAL <br />OPERATIONS, STOP WORK AND NOTIFY THE ARCHITECTS AND THE <br />OWNER, HAZARDOUS MATERIALS INCLUDE REGULATED ASBESTOS <br />CONTAINING MATERIALS, LEAD, PCB'S, AND MERCURY. <br />E. <br />PARTIAL REMOVAL OF PAVING AND CURBS: NEATLY SAW CUT AT <br />RIGHT ANGLE TO SURFACE. <br />3.03 DEBRIS <br />A. <br />REMOVE DEBRIS, JUNK, AND TRASH FROM SITE. <br />3.04 WASTE REMOVAL <br />A. <br />REMOVE FROM SITE ALL MATERIALS NOT TO BE REUSED ON SITE, DO <br />NOT BURN OR BURY. <br />B. <br />LEAVE SITE IN CLEAN CONDITION, READY FOR SUBSEQUENT WORK. <br />C. <br />CLEAN UP SPILLAGE AND WIND-BLOWN DEBRIS FROM PUBLIC AND <br />PRIVATE LANDS. <br />END OF SECTION <br />SECTION 02315 - FILL AND BACKFILL <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A. APPROPRIATE BACKFILL AND FILL MATERIAL FOR SITE PREPARATION <br />PART 2 PRODUCTS <br />2.01 BACKFILL <br />A. SUITABLE MATERIAL SHALL BE FREE OF LARGE LUMPS OR CLODS, <br />WHICH WILL NOT READILY BREAK DOWN UNDER COMPACTION. <br />B. SHALL BE FREE OF VEGETATION OR OTHER EXTRANEOUS MATERIAL. <br />C. MAY BE SUBJECT TO APPROVAL BY THE ENGINEER <br />2.02 TOPSOIL <br />D. TOP 3" OF FINISH EARTH GRADE SHALL BE TOPSOIL WITH NO <br />EXCESSIVE CLODS. <br />END OF SECTION <br />SECTION 024100 - DEMOLITION <br />PART 1 GENERAL <br />1.01 DESCRIPTION <br />A. THIS SECTION SPECIFIES DEMOLITION AND REMOVAL OF WALK, <br />CURBS, SLABS, PORTIONS OF BUILDINGS, UTILITIES, OTHER <br />STRUCTURES FROM BUILDING <br />1.02 PROTECTION <br />A. <br />PERFORM DEMOLITION IN SUCH MANNER AS TO ELIMINATE HAZARDS <br />TO PERSONS AND PROPERTY; TO MINIMIZE INTERFERENCE WITH USE <br />OF ADJACENT AREAS, UTILITIES AND STRUCTURES OR INTERRUPTION <br />OF USE OF SUCH UTILITIES; AND TO PROVIDE FREE PASSAGE TO AND <br />FROM SUCH ADJACENT AREAS OF STRUCTURES. COMPLY WITH <br />REQUIREMENTS OF GENERAL CONDITIONS ARTICLE, ACCIDENT <br />PREVENTION. <br />B. <br />PROVIDE SAFEGUARDS, INCLUDING WARNING SIGNS, BARRICADES, <br />TEMPORARY FENCES, WARNING LIGHTS, AND OTHER SIMILAR ITEMS <br />THAT ARE REQUIRED FOR PROTECTION OF ALL PERSONNEL DURING <br />DEMOLITION AND REMOVAL OPERATIONS. <br />C. <br />MAINTAIN FENCES, BARRICADES, LIGHTS, AND OTHER SIMILAR ITEMS <br />AROUND EXPOSED EXCAVATIONS UNTIL SUCH EXCAVATIONS HAVE <br />BEEN COMPLETELY FILLED. <br />D. <br />PREVENT SPREAD OF FLYING PARTICLES AND DUST. KEEP DUST TO A <br />MINIMUM. <br />E. <br />LOCAL FIRE AND SAFETY RULES TO BE OBSERVED IN PERFORMANCE <br />OF WORK, INCLUDE FOLLOWING: <br />1. WHEREVER A CUTTING TORCH OR OTHER EQUIPMENT THAT <br />MIGHT CAUSE A FIRE IS USED, PROVIDE AND MAINTAIN FIRE <br />EXTINGUISHERS NEARBY READY FOR IMMEDIATE USE. <br />INSTRUCT ALL POSSIBLE USERS IN USE OF FIRE <br />EXTINGUISHERS. <br />2. KEEP HYDRANTS CLEAR AND ACCESSIBLE AT ALL TIMES. <br />PROHIBIT DEBRIS FROM ACCUMULATING WITHIN A RADIUS OF <br />4500 MM (15 FEET) OF FIRE HYDRANTS. <br />F. <br />BEFORE BEGINNING ANY DEMOLITION WORK, THE CONTRACTOR <br />SHALL SURVEY THE SITE AND EXAMINE THE DRAWINGS AND <br />SPECIFICATIONS TO DETERMINE THE EXTENT OF THE WORK. THE <br />CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO AVOID <br />DAMAGES TO EXISTING ITEMS TO REMAIN IN PLACE, TO BE REUSED, <br />OR TO REMAIN THE PROPERTY OF THE TENANT OR LANDLORD. THE <br />CONTRACTOR SHALL COORDINATE THE WORK OF THIS SECTION WITH <br />ALL OTHER WORK AND SHALL CONSTRUCT AND MAINTAIN SHORING, <br />BRACING, AND SUPPORTS AS REQUIRED. THE CONTRACTOR SHALL <br />ENSURE THAT STRUCTURAL ELEMENTS ARE NOT OVERLOADED AND <br />SHALL BE RESPONSIBLE FOR INCREASING STRUCTURAL SUPPORTS <br />OR ADDING NEW SUPPORTS AS MAY BE REQUIRED AS A RESULT OF <br />ANY CUTTING, REMOVAL, OR DEMOLITION WORK PERFORMED UNDER <br />THIS CONTRACT. DO NOT OVERLOAD STRUCTURAL ELEMENTS. <br />PROVIDE NEW SUPPORTS AND REINFORCEMENT FOR EXISTING <br />CONSTRUCTION WEAKENED BY DEMOLITION OR REMOVAL WORKS. <br />REPAIRS, REINFORCEMENT, OR STRUCTURAL REPLACEMENT MUST <br />HAVE RESIDENT ENGINEER'S APPROVAL. <br />1.03 UTILITY <br />SERVICES <br />A. <br />DEMOLISH AND REMOVE OUTSIDE UTILITY SERVICE LINES SHOWN TO <br />BE REMOVED. <br />B. <br />REMOVE ABANDONED UTILITY LINES THAT WOULD INTERFERE WITH <br />INSTALLATION OF NEW UTILITY LINES AND NEW CONSTRUCTION. <br />PART 2 PRODUCTS (NOT USED) <br />PART 3 EXECUTION <br />3.01 DEMOLITION <br />A. DEBRIS, INCLUDING BRICK, CONCRETE, STONE, METALS AND SIMILAR <br />MATERIALS SHALL BECOME PROPERTY OF CONTRACTOR AND SHALL <br />BE DISPOSED OF BY HIM DAILY TO AVOID ACCUMULATION AT THE <br />DEMOLITION SITE. MATERIALS THAT CANNOT BE REMOVED DAILY <br />SHALL BE STORED IN AREAS SPECIFIED BY LANDLORD. BREAK UP <br />CONCRETE SLABS BELOW GRADE THAT DO NOT REQUIRE REMOVAL <br />FROM PRESENT LOCATION INTO PIECES NOT EXCEEDING 600 MM (24 <br />INCHES) SQUARE TO PERMIT DRAINAGE. CONTRACTOR SHALL <br />DISPOSE DEBRIS IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE <br />OR LOCAL PERMITS, RULES AND/OR REGULATIONS. <br />B. REMOVE AND LEGALLY DISPOSE OF ALL MATERIALS, FROM ANY <br />TRASH DUMPS ON SITE. MATERIALS REMOVED SHALL BECOME <br />PROPERTY OF CONTRACTOR AND SHALL BE DISPOSED OF IN <br />COMPLIANCE WITH APPLICABLE FEDERAL, STATE OR LOCAL PERMITS, <br />RULES AND/OR REGULATIONS. <br />3.02 CLEANUP <br />A. ON COMPLETION OF WORK OF THIS SECTION AND AFTER REMOVAL OF <br />ALL DEBRIS, LEAVE SITE IN CLEAN CONDITION SATISFACTORY TO <br />START CONSTRUCTION OF TENANT PROPERTY. <br />Z <br />0 <br />IL <br />EE <br />W <br />W <br />Q <br />W <br />IY <br />'!' <br />UN•*�• YSM•"•• • +� <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />JOB NO. <br />18390 <br />AS1 ol <br />