Laserfiche WebLink
QUAD ELEC. BOX <br />D-—Ul UTILITY CENTER <br />3)NOT TO SALE <br />GENERAL NOTES: <br />THIS DRAWING IS FOR INFORMATIONAL <br />PURPOSES ONLY. CONSULT ACTUAL <br />MANUFACTURER'S TEMPLATE WHEN <br />INSTALLING EQUIPMENT. <br />LOCAL REGULATIONS PROVIDE THAT <br />LICENSED PLUMBERS AND ELECTRICIANS <br />SHALL INSTALL UTILITIES. <br />ALL PLUMBING AND ELECTRICAL MUST <br />MAXIMUM HEIGHT <br />CONFORM TO PREVAILING LOCAL CODES. <br />OF OPENED <br />VALVE- 6" <br />AIR AND WATER: MANUALSHUT-OFP <br />VALVES. <br />VACUUM- 5/8-O.D. TUBE <br />ELEC. - ALLOW V! <br />OF 1/2" FLEX <br />ELECTRICAL° I I 5VAC, 60 HZ, TO BE <br />CONDUIT TO <br />INSTALLED WITH GFCI PROTECTED <br />EXTEND BEYOND <br />RECEPTACLE OUTLETS, CHECK AMPERAGE <br />STUB -UP FOR ELEC, <br />REQUIREMENTS, <br />HOOK-UPS <br />CONNECTIONS: <br />ALL NITROUS OXIDE LINES ARE 3/8!'O.D. <br />ALL <br />PIPING,O <br />02 <br />ALL OXYGEN LINES ARE I /2'O.D, INLET HOSE BARB <br />COPPER PIPING. USE D.I.S.S. FITTINGS TO INLET TO BAG TEE <br />CONNECTST I UBS TO FLOWMETER. <br />NOTE: D,I,S.S. FITTINGS MUST BE <br />ACCESSIBLE. <br />THIS IS A TYPICAL UNIT. <br />REFER TO MANUFACTURER'S <br />INSTALLATION LITERATURE TO VERIFY TOP VIEW <br />REQUIREMENTS. <br />CLEARANCE V-0 3/16" <br />FORHHOSE <br />41/2 115/9, <br />3 <br />t <br />CD <br />+ z E' <br />NITROUS OXYGEN m. <br />L-- — — <br />LEFT SIDE VIEW FRONT VIEW <br />NITROUS OXIDE FLOWMETER <br />NOT TO SCALE <br />GENERAL NOTES:, <br />THIS DRAWING IS FOR INFORMATIONAL PURPOSES ONLY. CONSULT ACTUAL MANUFACTURER'S TEMPLATE <br />WHEN INSTALLING EQUIPMENT. <br />LOCAL REGULATIONS PROVIDE THAT LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL UTILITIES. <br />ALL PLUMBING AND ELECTRICAL MUST CONFORM TO PREVAILING LOCAL CODES. <br />WATER* 35-40 PSI AIR: 70-80 PSI <br />1/2" O.D. (1.27cm) COPPER TUBING WITH I /Z'NPT MALE FITTING. STUB -Up 1-112'(3.81cm) FIRQ MANISHED, <br />FLOOR SURFACE. FLUSH ALL DEBRIS FROM LINE BEFORE INSTALLING VALVES, <br />NOTE: AIR AND WATER SHUT-OFF VALVES CAN NOT EXTEND MORE THAN 6" ABOVE FINISHED FLOOR <br />SURFACE, FULLY OPENED. <br />VACUUM. <br />WATER —AIR N20 02 5/6'O,D. (I .59trri) COPPER TUBING, TYPE L (.045 WALL THICKNESS), STUMP IlT (1.27cm) MIN., I" (2,54cm) <br />FINISHED FLOOR SURFACE <br />MAX FROM FINISHED FLOOR OR WALL SURFACE. ELBOW CONNECTION FURNISHED BY P&C TO BE <br />SOLDERED IN PLACE. <br />-----VACUUM' <br />ELECTRICAL: <br />STUB -UP WITH 1 /7'(1.27cm) FLEXIBLE CONDUIT FOR CONNECTION TO THE POWER STRIP. CIRCUIT SHOULD <br />BE 120 VAC. DEDICATED 15 AMP. <br />NODE: ELECTRICAL INSTALLATION MOST MEET ALL APPROPRIATE ELECTRICAL CODES, CONSULT ELECTRICAL <br />CONTRACTOR TO PROVIDE A Ill 5 VAC RECEPTACLE. <br />ISAL RI CABINET UTILITIES <br />NOT TO SC <br />ELECTRICAL CONTRACTOR IS USE 12 AWG WIRE BETWEEN CONTROL BOX AND <br />RESPONSIBLE FOR FOLLOWING ALL X-RAY UNIT FOR TOTAL WIRE LENGTH UP TO 50 FEET. <br />LOCAL CODES FOR ROUGH <br />INSTALLATION. HENRY SCHEIN TO 10 AWG WIRE IS REQUIRED WHEN WIRE LENGTH IS <br />­Q- <br />MAKE FINAL CONNECTIONS. BETWEEN 50-75 FEET, <br />ELECTRICIAN TO PROVIDE A <br />FLUSH -MOUNTED SINGLE GANG <br />JUNCTION BOX & 3/4!'CONDUIT W/ <br />PULL -WIRE FROM CONTROL BOX <br />TO X-RAY UNIT. <br />POWER FROM BUILDING MOUNTING PLATE. CONTROL <br />ELECTRICAL PANEL. 120V, BOX CAN BE MOUNTED <br />DEDICTATED 15A CIRCUIT ADJACENT TO X-RAY UNIT OR IN <br />HALL. SEE .SHEET SE.1 FOR <br />LOCATION, SEE HENRY SCHEIN <br />PANEL CUTOUT <br />NOTE OWER REP FOR EXACT HEIGHT. <br />LOW -VOLTAGE & WER <br />CABINET (SEE CABINET DRAWINGS <br />FOR ACTUAL CABINET LAYOUT) <br />AUTOCLAVE OUTLET SEPARATE CIRCUIT 20 AMP <br />HEIGHTS TO BE DETERMINED <br />0- <br />AUTOCLAVE PROVIDED AND <br />INSTALLED BY HENRY SCHEIN DENTAL <br />STATIM, OUTLET SEPARATE 15 AMP CIRCUIT <br />HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST <br />TO DETERMINE LOCATION. <br />NOTE* SWITCHED OUTLET RECOMMENDED. <br />--�STATIM PROVIDED AND INSTALLED <br />1 'no <br />BY HENRY SCHEIN DENTAL <br />CONDENSER BOTTLE <br />OUTLETS PROVIDED AND <br />INSTALLED BY CONTRACTOR <br />AUTOCLAVE AND STATIM OUTLET. <br />NOT TO SCALE <br />MODEL <br />1025D <br />5 <br />TOTAL HP <br />1.5 <br />VOLTAGE <br />230 <br />BREAKER$Zi <br />20A <br />HERTZ <br />610 <br />AMPS <br />8.4 <br />TANKSIZE <br />10 GAL. <br />WIDTH <br />24-3U' <br />DEPTH <br />20,$-271, <br />1 HEIGHT <br />2615 30" <br />IWEIGHT <br />174LBS <br />NOTES. <br />1. SUPPLY HOSE, 1/4'mtpx3/6'mtp, &LONG (SUPPLIED) <br />2. DRAIN TUBING, 3/9'PLASTIC, 4' LONG (SUPPLIED) <br />3. BUSHING, I]Tmpt x 3/Vlfpt (SUPPLIED) <br />4. ALLOW 6" S . ERVICE CLEARANCE ON SIDES., BACK AND TOP OF COMPRESSOR. <br />MAINTAIN I Z'CLEARANCE IN FRONT OF COMPRESSOR. <br />CONNECT FRESH AIR INTAKE (USES V HOSE BARB) TO <br />EXTERNAL AIR SOURCE PER NFPA 99C <br />RECOMMENDATIONS. <br />CONNECT UNIT TO OUTLET ON 230V, 20A DEDICATED <br />CIRCUIT. <br />LOW -VOLTAGE CONTROL WIRING TERMINALS. MAX. <br />DISTANCE FOR 18 GA. WIRE-- 500 FT, <br />CONNECT UNIT TO FACILITY PLUMBING USING PROVIDED <br />SUPPLY HOSE. USE BUSHING IF NECESSARY. <br />NOTE: <br />INSTALL UNIT PER. FOLLOWING ALL LOCAL & STATE CODES. <br />RMC1025D IRCAOMPRESSOR <br />j NOT TO SCALE <br />MAY REQUIRE SEPARATE <br />JUNCTION BOXES. VERIFY LOCAL <br />CODE REQUIREMENTS. <br />di <br />uj <br />LOW -VOLTAGE WIRE TO X-RAY <br />> <br />UNIT (SPEC. 9) <br />SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE DETAIL, <br />BEL 096 X—RAY CONTROL BOX <br />NOT TO SCALE <br />DOUBLE BOWL SINK <br />(MAY VARY TO SINGLE BOWL) <br />RECESSED ULTRASONIC CLEANER <br />REMOTE TIMER PANEL <br />ULTRASONIC CLEANER <br />DRAIN <br />ULTRASONIC CLEANER GENERATOR <br />ADJUSTABLE SHELF <br />1 <br />ULTRASONIC CLEANER. <br />NOT TO SCALE <br />ODEL <br />QT- 1,2 <br />VERIFY AMBIENT ROOM <br />DISCONNECT <br />)TAL HP <br />1.0 <br />---9-5/-230 <br />TEMPERATURE AND <br />D.LTAGE <br />VENTILATION REQUIREMENTS <br />DEDICATED <br />'EAKER SZ, <br />20A <br />WITH MANUFACTURE <br />CIRCUIT <br />RTZ <br />mps <br />13.4/6,7 <br />PRE -INSTALLATION GUIDE <br />7 <br />BUILDING <br />IDTH <br />25' <br />POWER <br />=PTH <br />SUPPLY <br />PANEL <br />TO OPTIONAL REMOTE <br />CONT ZOL PANEL Q <br />EXHAUST TO <br />ELECTROL <br />OUTSIDE BUILDING <br />(SUPPLIED BY RAMVAC) <br />(Z'SCH. 80 PVC <br />OR METAL) <br />JUNCTION BOX <br />(OPTIONAL) <br />0 <br />15 GAL. OTTER <br />TANK <br />TREATMENT ROOM <br />DRAIN LINE (TO <br />SEE DETAIL(S) 1,3 OR 3A FOR VACUUM <br />FLOOR DRAIN <br />LINE STUB -UP REQUIREMENTS WITHIN <br />. <br />OR P-TRAP) -I 1 /2' <br />ROOM. <br />PV PI <br />C <br />FLOOR PE <br />--------- - - TR TANK LINE- 1 1/2'OR 2" PVC W/ DWV <br />VACUUM LINES PER LOCAL CODE, FITTINGS OR COPPER PER LOCAL CODE <br />SLOPE MINIMUM I/4PPER 10 FEET. WOTEW' <br />REFER TO RAMVAC SPECS AND PRE -INSTALLATION GUIDE FOR <br />EXACT REQUIREMENTS. VERIFY LOCAL CODES BEFORE INSTALLING <br />UNIT, <br />\BULLDOG COMBO 1 &2 <br />NOT TO SCALE <br />ELECTRICAL CONTRACTOR IS <br />RESPONSIBLE FOR FOLLOWING ALL <br />LOCAL CODES FOR ROUGH <br />INSTALLATION. HENRY SCHEIN TO <br />MAKE FINAL CONNECTIONS. <br />ELECTRICIAN TO PROVIDE A <br />FLUSH -MOUNTED SINGLE GANG <br />JUNCTION BOX & 3/4!'CONDUIT W/ <br />PULL -WIRE BETWEEN EXPOSURE <br />BUTTON & X-RAY MASTER <br />CONTROL/UNIT.—���� <br />X -RAY EXPOSURE BUTTON f".)— <br />VERIFY WIRING REQUIREMENTS <br />BETWEEN EXPOSURE BUTTON <br />AND X-RAY MASTER <br />CONTROL/UNIT WITH <br />MANUFACTURER'S INSTALLATION <br />MANUAL. <br />PROVIDED BY HENRY-SCHEIN DENTAL, INSTALLED BY ELECTRICIAN. <br />SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE DETAIL. <br />X—RAY EXPOSURE BUTTON <br />NOT TO SCALE <br />COLD WATER, <br />PLUMBER.'SHALL <br />PROVIDE AND <br />INSTALL A CHROME <br />PLATED ANGLE <br />STOP (VALVE) TO BE <br />LOCATED AT <br />MODEL TRIMMER <br />MODEL TRIMMER - <br />115V. 15AMP. ELEC. <br />OUTLET FOR MODEL <br />TRIMMER., <br />DRAIN HOSE FROM <br />MODEL TRIMMER TO <br />EXPEL INTO SINK. <br />DRAIN HOSE <br />--- <br />me <br />FRONT VIEW <br />MODEL TRIMM <br />NOTTO.SCALE <br />314- UNION (2 P' <br />PROVIDED BY PI <br />I I 5V WALL OUT <br />WITHIN 5'OF Wi <br />FILTER BYPASS, <br />LOW VOLTAGE <br />CONTROL WIRE <br />STANDARD LAB SINK <br />SUPPLIED AND INSTALLED <br />BY PLUMBER <br />FLEX.HOSE (SUPPLIED) <br />0 SINK DRAIN <br />0 PLASTER TRAP & HOSES <br />PROVIDED BY HENRY <br />SCHEIN DENTAL AND <br />INSTALLED BY PLUMBER. <br />BASE OF SINK CABINET <br />SIDEVIEW <br />DISP. PLASTER TRAP <br />NOTE: <br />WHEN MOUNTING FROM ABOVE OUTLET STATION. <br />VACUUM PIPING FOR GAS SCAVENGING MUST <br />INCLUDE VERTICAL LOOP TO PREVENT BACKFLOW <br />OF LIQUIDS INTO VACUUM BLOCK. <br />1/2" 01). VACUUM <br />LINE <br />1/7'O.D. OXYGEN <br />FROM TANK ROOM <br />3/8" O.D. NITROUS <br />FROM TANK Room <br />WALL FRAMING------_., <br />BRACKET "A" TO <br />MOUNT TO STUD <br />BEFORE GYP. BIRD - --------- <br />PROVIDED BY HENRY SCHEIN <br />DENTAL AND INSTALLED BY <br />PLUMBER <br />THIS DRAWING REPRESENTS A TYPICAL INSTALLATION AND IS FOR INFORMATIONAL PURPOSES ONLY. <br />REVIEW MANUFACTURER SPECIFICATIONS FOR EXACT MODEL AND SYSTEM REQUIREMENTS. <br />N20,02AND VACUUM OUTLET STATION <br />NOT TO SCALE <br />SEE ACTUAL VALVE TO <br />ADJUST THE MOUNTING <br />POSITION OF THE 1, 2„ FPT <br />ADAPTOR SO THE. TRIM RING IS <br />SECURED FIRMLY AGAINST THE <br />S.HEETROCK. <br />AIR VALVE PROVIDED AND <br />INSTALLED BY CONTRACTOR, <br />3/9'COMPRESSION FITTING <br />OR OPTIONAL FEMALE QUICK <br />DISCONNECT PROVIDED & <br />INSTALLED BY CONTRACTOR. <br />AIR VALVE <br />NOT TO SCALE <br />I ITSUP x I /Z'FPT ADAPTOR. <br />PROVIDED & INSTALLED BY <br />CONTRACTOR, <br />1/2" FEMALE ADAPTOR <br />PROVIDED & INSTALLED BY <br />QNTRACTOR. <br />AIR LINE BY CONTRACTC <br />Q- ®R <br />ANCHOR TERMINATION <br />FITTINGS SECURELY TO A <br />OR A CROSS BRACE. <br />FITTINGS PROVIDED AND <br />INSTALLED BY CONTRAC <br />VACUUM WALL OUTLET <br />NOT TO SCALE <br />LOW VOLTAGE CONTROL WIRES - <br />RUN 18/3 BELL WIRE FROM UNITS TO <br />MASTER CONTROL PANEL <br />(CONTRACTOR TO SUPPLY WIRE) <br />STUB PIPE OUT OF STANDARD SINGLE GANG BOX (2-1/8" D x <br />WALL 6" 4!'H x 7'W) SUPPLIED BY ELECTRICIAN <br />MASTER WATER SHUT—OFF W/FILTER <br />NOT TO SCALE <br />1 /7'PVC SLIP X SLIP, 900 <br />ELBOW. PROVIDED �& <br />INSTALLED: BY CONTRACTOR. <br />ANCHOR TERMINATION <br />FITTINGS SECURELY TO A STUD <br />OR A CROSS BRACE, <br />FITTINGS PROVIDED AND <br />INSTALLED BY CONTRACTOR. <br />I /Z'SC-H 40 PVC BRANCH <br />FROM MAIN TRUNK LINE. <br />PROVIDED & INSTALLED BY <br />CONTRACTOR. <br />60" <br />THIS IS A TYPICAL INSTALLATION. SEE A.F.F. <br />MAN U FACTURER'S SPECS FOR EXACT <br />EQUIPMENT REQUIREMENTS. <br />, n RA M�V �ACCONTROL PANEL <br />NOT TO SCALE <br />ISSUE <br />DATE <br />REAM <br />02/22AI <br />PERMIT <br />02/23/11 <br />REV. <br />REV. <br />REV. <br />IREV. <br />7tME POUMM VM05 NOTE5 MTAiL5 NO <br />935CMAWM AND CONCEPTS ARE IM SOLE <br />MMM OF MAZE MM M AND SHALL NOT BE <br />N"==, M-USED OR GOP® FOR Mat <br />PROJMI% IN MOLE OR FM MW 7W W7N <br />CONSENT Of MW FRAM ARGHr=T, AIA6 <br />ALL ROM AM IMURVW BY THE ARCHITECT IN <br />ACCORDANCE NTH UA COMIOW AND FATEW LAWS. <br />WAmimm REPRO zTm YcL BE Mwwfxw To <br />THE FULL EXTENT OF THE LW <br />O <br />V) <br />w <br />W <br />/-� <br />;4 <br />0 <br />4-4 <br />con <br />4-a <br />U <br />1.4 <br />0 <br />u <br />OfM-9910NAL 5C6L <br />1,.EO <br />Glta s ..C) <br />0 ®° <br />0 <br />00 <br />uj <br />ZP <br />gap I A <br />SHEET TITLE <br />M.UMIDING <br />DETAILS <br />