r� FLOOR PLAN <br />�j <br />xdnx <br />SCALE: 1/8" = 1'-0" <br />FLOOR PLAN UNREFERENGED NOTES <br />I. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL <br />GOVERN. LARGE SCALE DRAWINGS SHALL GOVERN OVER <br />SMALLER SCALE DRAWINGS. CONTACT INTERIOR <br />DESIGNER/ARCHITECT TO CONFIRM ALL DISCREPANCIES. <br />2. ALL INTERIOR DIMENSIONS ARE FROM FACE OF FINISH TO <br />FACE OF FINISH (FOF) UNLESS OTHERWISE NOTED AS FACE <br />OF STUD (FOS) OR FACE OF MASONRY (FOM). <br />3. ALL WORK SHALL CONFORM WITH DRAWINGS AND <br />SPECIFICATIONS AND SHALL BE IN CONFORMANCE WITH ALL <br />APPLICABLE GOVERNING MUNICIPAL AND REGULATORY <br />AGENCIES, CODES AND REQUIREMENTS. IT SHALL BE <br />UNDERSTOOD THAT ALL INTENDED WORK IS SUBJECT TO <br />REVIEW AND INTERPRETATION BY THE ADMINISTRATIVE <br />AUTHORITY HAVING JURISDICTION AND IN NO CASE SHALL <br />WORK BE PERFORMED WITHOUT THE REVIEW AND WRITTEN <br />APPROVAL OF SAID AUTHORITY. THE CONTRACTOR SHALL <br />BE RESPONSIBLE FOR ALL FEES RELATED TO THE ISSUE OF <br />PERMITS, INSPECTIONS AND CERTIFICATES NECESSARY FOR <br />THE EXECUTION AND COMPLETION OF THE WORK AND THE <br />OCCUPANCY OF THE AREA OF WORK. <br />4. ALL NEW DRYWALL PARTITIONS ARE TO BE TAPED, <br />BEDDED, AND SANDED TO RECEIVE FINISH AS PER FINISH <br />SCHEDULE AND/OR FINISH PLAN. THE GENERAL <br />CONTRACTOR SHALL COORDINATE THE MINIMUM LEVEL OF <br />DRYWALL FINISH WITH THE SPECIFIED FINISH MATERIAL <br />MANUFACTURER'S RECOMMENDED LEVEL OF FINISH PRIOR <br />TO INSTALLATION. <br />5. PROVIDE FIRE EXTINGUISHER(S) HAVING A MINIMUM RATING <br />OF 2-A, 10-BC FOR EVERY 3,000 SO FT. EXTINGUISHERS <br />SHALL BE CONSPICUOUSLY LOCATED AND READILY <br />ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL BE <br />MOUNTED AT 48" ABOVE FINISHED FLOOR AND IN NO CASE <br />SHALL BE MORE THAN 5 FEET ABOVE THE FLOOR. THE <br />BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS THAN <br />4 INCHES FROM THE FLOOR. TRAVEL DISTANCE TO AN <br />EXTINGUISHER SHALL NOT EXCEED 75 FEET. INSTALL IN <br />ACCORDANCE WITH CLASSIFICATION, RATING AND <br />DISTRIBUTION REQUIREMENTS OF NFPA 10. <br />6. GC SHALL VISIT THE SITE PRIOR TO COMMENCING WORK. <br />VERIFY AND DISCREPANCIES BETWEEN DRAWINGS AND <br />ACTUAL JOB CONDITIONS PRIOR TO PROCEEDING WITH THE <br />JOB. CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR <br />THE ACCURACY OF FIELD MEASUREMENTS AND CONDITIONS <br />AND SHALL BE RESPONSIBLE FOR THE PROPER <br />ADAPTATION OF THEIR WORK TO ANY EXISTING WORK OR <br />PREVIOUSLY INSTALLED WORK OF OTHER TRADES. WRITTEN <br />APPROVAL MUST BE OBTAINED FROM THE ARCHITECT <br />PRIOR TO MAKING ANY FIELD CHANGES. ANY COSTS <br />ASSOCIATED WITH FIELD CHANGES OR DEVIATIONS FROM <br />THE DRAWINGS AND SPECIFICATIONS MADE WITHOUT PRIOR <br />APPROVAL FROM THE ARCHITECT SHALL BE THE <br />RESPONSIBILITY OF THE GENERAL CONTRACTOR. <br />7. ANY EXISTING CONCEALED BUILDING STRUCTURAL <br />CONDITIONS NOT INDICATED IN BASE BUILDING <br />ARCHITECTURAL PLANS OR UNCOVERED DURING DEMOLITION <br />WHICH MAY REQUIRE DESIGN REWORK AND A CHANGE IN <br />CONSTRUCTION SHALL HOLD THE AUTHOR OF THESE <br />DOCUMENTS HARMLESS FROM ANY CLAIM, LIABILITY OR <br />COSTS ASSOCIATED WITH THE HIDDEN CONDITION. THE <br />CLIENT SHALL UNDERSTAND THAT CERTAIN PROFESSIONAL <br />DESIGN INDUSTRY ASSUMPTIONS SHALL BE MADE <br />REGARDING THE EXISTING CONDITIONS AND SOME OF THESE <br />ASSUMPTIONS MAY NOT BE VERIFIABLE WITHOUT <br />EXPANDING ADDITIONAL SUMS OF MONEY OR DESTROYING <br />OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF THE <br />BUILDING. <br />8. THE SPACE SHALL BE THOROUGHLY CLEANED, INCLUDING <br />WINDOWS AND BLINDS, BEFORE TURN OVER TO THE <br />TENANT. CONTRACTOR SHALL PROVIDE A TRASH <br />DUMPSTER FOR TRASH REMOVAL. TRASH REMOVAL FROM <br />THE SITE SHALL OCCUR BEFORE THE END OF EACH <br />WORKDAY. IF APPLICABLE, THE BUILDINGS JANITOR SINK <br />MAY BE USED AS WATER SOURCE, BUT MUST BE KEPT <br />CLEAN. IF APPLICABLE, BUILDING FREIGHT ELEVATOR MAY <br />BE USED, BUT MUST BE KEPT CLEAN. <br />9. ALL WORK SHALL BE FREE OF DEFECTS, FOR A PERIOD <br />OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. <br />ALL SUCH DEFECTS SHALL BE CORRECTED BY THE <br />CONTRACTORS(S) AT NO EXPENSE TO THE OWNER. <br />10. CONTRACTOR SHALL BE RESPONSIBLE FOR <br />PROTECTING ALL EXISTING CONDITIONS FROM DAMAGE <br />DURING CONSTRUCTION. <br />II. GENERAL CONTRACTOR TO FURR OUT ALL COLUMNS - <br />"FURR TIGHT". IF ELECTRICAL IS REQUIRED AT COLUMNS, GC <br />TO FURR TO ACCEPT ELECTRICAL. <br />12. FIRE RETARDANT LUMBER SHALL BE USED IN WALLS <br />WHERE WOOD IS REQUIRED , INCLUDING BLOCKING FOR <br />WORK SURFACES, SHELVING, BRACKETS, DISPLAYS, AND/OR <br />EQUIPMENT WHICH WILL BE MOUNTED OR ATTACHED TO <br />FACE OF WALL. <br />FLOOR PLAN LEGEND <br />EXISTING PARTITION OR CONSTRUCTION TO <br />REMAIN <br />NEW PARTITION OR CONSTRUCTION <br />FLOOR PLAN GENERAL NOTES <br />I. ALL EXISTING INTERIOR DOORS TO RECEIVE NEW FINISH <br />WITHIN AREA OF WORK. REFER TO FINISH PLAN. <br />2. NEW FLOOR FINISH THROUGHOUT ENTIRE SPACE WITHIN <br />AREA OF WORK. REFER TO FINISH PLAN. <br />FLOOR PLAN KEY NOTES <br />❑1 INFILL OPENING WITH CONSTRUCTION TO MATCH EXISTING <br />2❑ PATCH AND REPAIR DRYWALL TO MATCH EXISTING <br />I FAFAA1 A Oki OTA I : I ki <br />ARCH 1 T T U RE <br />Daniel H, Farmer' AJ,k <br />License R1075" <br />Lake Baldwiri !.-ane <br />Orlando, FL 32814 <br />, 44 . 0 <br />7ju �,- 3 .4, '9 0 i <br />z <br />O <br />LLJ <br />J <br />Q <br />O_ <br />E <br />Lu <br />z <br />Q <br />Q <br />J <br />LO <br />Q <br />Q <br />O <br />z <br />O <br />U <br />d� <br />O <br />'t <br />0 <br />Nt <br />LO <br />00 <br />C'M <br />Q <br />0 <br />H <br />U) <br />J_ <br />w <br />N <br />