My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38010 Medical Center Ave (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38010 Medical Center Ave (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:30:32 AM
Creation date
2/28/2025 8:09:37 AM
Metadata
Fields
Template:
Building Plans
Street #
38010
Location
Medical Center Ave
Contractor
Contract Levelie Construction
Building Plans - Permit #
17644
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />IDS <br />TO CT EQUIP <br />ELECTRICAL PARTIAL <br />LIGHTING FLOOR PLAN - DEMOLITION <br />SCALE: 1 /4" = 1' - 0" <br />EXISTING EQUIP <br />CONDUITS ROUTE <br />9hf <br />PNL L <br />i3I <br />t <br />L B-29 <br />GE <br />PANEL <br />6 <br />2.5 TON CU 5 TON CU <br />8 01,0 <br />'LL <br />LASER � MONITOR MONITOR <br />�o 0 <br />L B-33 <br />LASER <br />—RECEPT <br />LB 33` c) <br />9 P LB-27 <br />LB-27 LB-29 <br />EXISTING <br />W MONITOR <br />T_- -. i:Z�i <br />on <br />'LB-33' <br />�---41 <br />AHU-4 <br />7 <br />ELECTRICAL PARTIAL <br />POWER & SYSTEMS FLOOR PLAN - DEMOLITION <br />00 <br />0 <br />200A <br />DISC. <br />EXISTING <br />METER <br />i <br />LIMITS OF DEMOLITION <br />1) DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL FIXTURES, DEVICES, PANEL BOARDS AND <br />CONNECTIONS TO EXISTING ELECTRICAL EQUIPMENT IN THIS AREA UNLESS OTHERWISE NOTED <br />HERE OR ON OTHER DRAWINGS. ALL EXISTING RACEWAYS PASSING THROUGH THIS AREA FEEDING <br />OTHER AREAS SHALL REMAIN INTACT AND OPERATIONAL, ALL OTHER RACEWAYS SHALL BE <br />REMOVED. <br />2) CONTRACTOR SHALL MAINTAIN EXISTING FIRE ALARM SYSTEM WITHIN AREA OF DEMOLITION <br />THROUGHOUT CONSTRUCTION PERIOD. PROVIDE SMOKE DETECTORS COVERS DURING WORK <br />REMOVE SMOKE DETECTOR COVERS OUTSIDE OF WORK HOURS. <br />3) THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER FOR THE EXHAUST FAN PROVIDED <br />DURING DEMOLITION AND CONSTRUCTION WITH IN THE PROJECT LIMITS, FROM THE EQUIPMENT <br />BRANCH OF THE ESSENTIAL SYSTEM. <br />4) ALL EXISTING CEILING MOUNTED DEVICES (SPEAKERS, FIRE STROBES, SMOKE DETECTORS, EXIST <br />SIGNS, ECT) WITHIN IN LIMITS OF DEMOLITION ARE TO BE SALVAGE FOR RE -LOCATION. CONTRACTOR <br />SHALL TAG EXISTING FEED AND EXTEND AS NEEDED FOR RECONNECTION. <br />RL DENOTES RELOCATED DEVICE. <br />KEY NOTES <br />OCONTRACTOR SHALL REMOVE AND STORE EXISTING LIGHTING FIXTURES WITHIN PROJECT <br />DEMOLITION SCOPE. TAG ALL EXISTING LIGHTING CIRCUITS FOR REUSE DURING RENOVATION. ALL <br />ABANDONED CIRCUIT NOT USED TAKE BACK TO SOURCE. <br />O2 LIGHTING SWITCHING CIRCUITS ARE TO BE RELOCATED. CONTRACTOR SHALL TAG EXISTING <br />CIRCUITS BREAKERS APPROPRIATELY DURING DEMOLITION FOR RE -USE IN RENOVATION. <br />OEXISTING "XRAY IN USE" LIGHT AND DOOR SWITCH TO BE REMOVED. MAINTAIN AND EXTEND <br />EXISTING CIRCUIT FOR RE -USE. REFER TO VENDOR DRAWINGS FOR ADDITIONAL INFORMATION. <br />OPROVIDE TEMPORARY ELECTRICAL CONNECTION FOR CONSTRUCTION VENTILATION NEGATIVE AIR <br />MACHINE. UPON COMPLETION OF PROJECT RETURN TEMPORARY CIRCUIT TO SPARE BREAKER. <br />COORDINATION WITH MECHANICAL DRAWINGS AND OWNER'S ICRA PLAN FOR REQUIREMENTS. <br />OEXISTING VENDOR EQUIPMENT SERVING ADJACENT ROOM TO REMAIN. PROTECT DURING <br />DEMOLITION PHASE. <br />O6 REMOVE EXISTING EQUIPMENT ECB PANEL WITH MAIN SHUNT TRIP CIRCUIT BREAKER. <br />CONTRACTOR SHALL DISCONNECT EXISTING FEEDERS AND CAP/TAG CONDUITS AND <br />CONDUCTORS AFTER DEMOLITION WORK IS COMPLETED. REFER TO RISER DIAGRAM SHEET FOR <br />MORE INFORMATION. <br />0 REMOVE EXISTING AHU-4, ASSOCIATED CU-UNIT AND DISCONNECTING MEANS. CAP AND TAG <br />EXISTING CONDUITS AND CONDUCTORS SERVING MECHANICAL EQUIPMENT. LABEL BREAKER AS <br />OSPARE IN EXISTING PANEL <br />8 <br />REMOVE EXISTING ELECTRICAL PANEL FRAME AND CASING IN LOCATION SHOWN IN <br />PREPARATION FOR NEW ELECTRICAL EQUIPMENT. SEE NEW WORK PLAN FOR ADDITIONAL <br />INFORMATION. <br />DEMOLITION LEGEND <br />SYMBOL <br />DESCRIPTION <br />--- -- <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED <br />-- <br />DEMO TO THIS POINT <br />AA 26001479 <br />Sheet Notes: <br />Smith <br />Seckman <br />k%.-kReid, Inc. <br />301 North Cattlemen Road, Suite 300 <br />Sarasota, FL 34232 <br />(941) 907-7750 <br />FAX: (941) 907-7751 <br />www.ssr-inc.coni <br />Firm Certification - CA-0000857 <br />SSR# 1636044.0 <br />Erick Phelps - PE #64598 <br />Christopher E. Durham - PE #76655 <br />EDWAR�o <br />ENS <br />No. <br />N_ 0. 7 5 <br />, OSTATE OF C(�` <br />�i��s'•:c�ORIDP.•'• G�� <br />Christopher Edward Durham <br />PE License No. 76655 <br />Key Plan <br />MARK ISSUE DATE DESCRIPTION <br />Issue Log <br />CONSTRUCTION <br />DOCUMENTS <br />FLORIDA CANCER SPECIALISTS <br />EQUIPMENT REPLACEMENT <br />38010 MEDICAL CENTER AVE. <br />ZEPHYRHILLS, FL 33540 <br />Drawing Title <br />ELECTRICAL <br />PARTIAL FLOOR PLAN <br />- DEMOLITION <br />rMISTI►� <br />06/29/2016 <br />SCALE: 1 /4" = 1' - 0" <br />Scale 1/4" = 1' - 0" <br />Sheet Number <br />E201 <br />Drawn By KIDS <br />Approved By MLG <br />Filename <br />ScUtCo, LLC 2007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.