Laserfiche WebLink
NON TEMPERED SUPPLY FAN <br />(DOWN DISCHARGE) <br />MUA FAN INFORMATION <br />FAN UNIT MODEL # CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) SONES <br />A1—G10D 726/800 0.500 800 1.000 1 115 10.2 212.56 15.5 <br />VERIFY <br />ECM Wiring Package — Manual Speed Control. <br />CURB ASSEMBLIES <br />ON WEIGHT ITEM SIZE <br />FAN <br />A1—G10D 1 29 LBS <br />Curb <br />21.000"W x 21.000"L x 20.000"H <br />*NOTE: Verify CFM with Hood Drawing <br />A1-G10D - SUPPLY FAN <br />1. DIRECT DRIVE DIRECT DRIVE UNTEMPERED SUPPLY UNIT <br />10" BLOWER IN SIZE #1 HOUSING WITH SPEED CONTROL, DISCONNECT SWITCH. <br />2. INTAKE HOOD WITH EZ FILTERS <br />3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT <br />4. ECM WIRING PACKAGE AND MANUAL CONTROL FOR ECM MOTORS ON PRVS. <br />GRIDDLE FAN (CANOPY HOOD) <br />EXHAUST FAN INFORMATION <br />FAN UNIT MODEL # <br />MODEL <br />CFM <br />ESP. <br />RPM <br />H.P. <br />0 <br />VOLT <br />FLA <br />WEIGHT (LBS.) <br />SONES <br />DU50HFA <br />DU50HFA <br />1000 <br />1.000 <br />1359 <br />0.500 <br />1 <br />115 <br />8.1 <br />64.81 <br />12.9 <br />FAN OPTIONS <br />1 — Grease Box <br />CURB ASSEMBLIES <br />ON <br />FAN <br />WEIGHT <br />ITEM <br />SIZE <br />DU50HFA <br />31 LBS <br />Curb <br />19.500"W x 19.500"L x 20.000"H Vented Hinged <br />BREAD OVEN FAN <br />FXHAU�T FAN INFORMATION <br />FAN UNIT MODEL # <br />CFM <br />ESP. <br />RPM <br />H.P. <br />0 <br />VOLT <br />FLA <br />WEIGHT (LBS.) <br />SONES <br />DU33HFA <br />562 <br />0.750 <br />1361 <br />0.333 <br />1 <br />115 <br />4.1 <br />52.56 <br />8.4 <br />FAN OPTIONS <br />1 — Gravity Back Draft Damper <br />CURB ASSEMBLIES <br />ON <br />FAN <br />WEIGHT <br />ITEM <br />SIZE <br />DU33HFA <br />30 LBS <br />Curb <br />19.500"W x 19.500"L x 22.000"H <br />FEATURES: <br />ROOF MOUNTED FANS <br />RESTAURANT MODEL <br />UL705 AND UL762 <br />VARIABLE SPEED CONTROL <br />INTERNAL WIRING <br />WEATHERPROOF DISCONNECT <br />THERMAL OVERLOAD PROTECTION (SINGLE PHASE) <br />HIGH HEAT OPERATION 300°F (149°C) <br />GREASE CLASSIFICATION TESTING <br />NORMAL TEMPERATURE TEST <br />EXHAUST FAN MUST OPERATE CONTINUOUSLY <br />WHILE EXHAUSTING AIR AT 300°F (149°C) <br />UNTIL ALL FAN PARTS HAVE REACHED <br />THERMAL EQUILIBRIUM, AND WITHOUT ANY <br />DETERIORATING EFFECTS TO THE FAN WHICH <br />WOULD CAUSE UNSAFE OPERATION. <br />ABNORMAL FLARE—UP TEST <br />EXHAUST FAN MUST OPERATE CONTINUOUSLY <br />WHILE EXHAUSTING BURNING GREASE VAPORS <br />AT 600°F (316°C) FOR A PERIOD OF <br />15 MINUTES WITHOUT THE FAN BECOMING <br />DAMAGED TO ANY EXTENT THAT COULD CAUSE <br />AN UNSAFE CONDITION. <br />OPTIONS <br />GREASE BOX <br />1 3/4" <br />27 <br />13 1 /4" <br />3 7/8" <br />29 3/4" <br />25 <br />BLOWER DISCHARGE <br />11 1 /2" <br />32 1 /8" <br />AIRFLOW <br />f— SERVICE <br />DISCONNECT <br />SWITCH <br />BLOWER/MOTOR <br />ACCESS DOOR <br />24" SERVICE <br />�21 <br />FAN #1 DU50HFA — EXHAUST FAN <br />DUCTWORK BETWEEN <br />EXHAUST RISER ON HOOD <br />AND FAN (BY OTHERS) <br />FAN #2 DU33HFA — EXHAUST FAN <br />17 1/2 <br />21 <br />DUCTWORK BETWEEN <br />EXHAUST RISER ON HOOD <br />AND FAN (BY OTHERS) <br />/2 <br />/2 <br />/2 <br />30 1 /4 <br />2 <br />LIFTING LUG <br />3 3/41' <br />16 1 /4" <br />20" EQUIPMENT CURB <br />�21 <br />ROOF OPENING 2" SMALLER THEN CURB DIMENSION. <br />14101111:1:: <br />'0 GAUGE <br />TEEL <br />;ONSTRUCTION <br />NGE <br />/ ROOF OPENING <br />DIMENSIONS <br />17 1/12 17 1/2 <br />2 <br />FA <br />C1m7 <br />'0 GAUGE <br />�TEEL <br />:ONSTRUCTION <br />I „N G E <br />/ ROOF OPENING <br />DIMENSIONS <br />171 /2 17 1 /2 <br />SAMUEL <br />OLMEDO <br />ARCHITECT <br />FL. REG. AR0015027 <br />TEL. 407. 967. 3109 <br />soarcht @ yahoo.com <br />P.O. BOX 784825 <br />WINTER GARDEN, FL. 34778 <br />CONSULTANT <br />CONSULTANT <br />REVISIONS: <br />NO . DATE DESCRIPTION <br />INSTRUMENTS OF SERVICE OWNERSHIP <br />ALL REPORTS, PLANS, SPECIFICATIONS, <br />COMPUTER FILES, FIELD DATA, NOTES <br />INSTRUMENTS PREPARED BY THE <br />AND OTHER DOCUMENTS AND RELATED <br />INSTRUMENTS PREPARED BY THE <br />ARCHITECT OR CONSULTANTS AS <br />INTRUMENTS OF SERVICE SHALL REMAIN <br />THE PROPERTY OF THE ARCHITECT OR <br />CONSULTANT, THE ARCHITECT AND OR <br />THE CONSULTANT SHALL RETAIN ALL <br />COMMON LAW, STATUTORY AND OTHER <br />RESERVED RIGHTS, INCLUDING THE <br />COPYRIGHT THERETO. <br />MR. RANDY HAGAR <br />& <br />MR. JOSHUA LINCOLN <br />ZEPHYR COMMONS <br />SHOPPING CENTER <br />7890 H WY 301 <br />ZEPHYRHILLS FLORIDA <br />FAN SCHEDULES <br />M3 <br />EET NUMBER <br />u r <br />SAMUEL OLMEDO <br />AR0015027 <br />