El <br />GENERAL H.V.A.C. NOTES <br />1. The contractor shall furnish all labor, material and equipment <br />for a complete H.V.A.C. system in accordance with these drawings. <br />The Florida Building Code 2010 and the latest edition of the <br />following publications: <br />(o)ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 <br />(c) SMACNA (d) ASHRAE. <br />2. All air conditioning ductwork shall be 1 1/2 " standard duty <br />foil reinforced fiberglass (R-6) manufactured logo printed on the <br />vapor barrier. <br />3. All exhaust ductwork shall be code gage galvanized sheet metal. <br />4. Duct size shown are net free area inside. <br />5. All air devices (diffusers, registers and grilles) shall be all <br />aluminum construction, with exposed surface chemically treated to <br />receive paint to match color or AIRGUIDE or approved equal. <br />6. Provide opposed blade dampers at all diffusers and registers. <br />7. Thermostats shall be combination cooling/heating with system <br />Cool/Auto/Heat/Off and Fan On/Auto selector switches. <br />8. Refrigerant piping shall be copper type I" with 3/4" armaflex. <br />Insulation shall be provided for suction lines. <br />9. Provide new filters for fan coil before starting. These <br />filters must also be replaced prior to final acceptance by owner. <br />�3 4" DEEP x 118 <br />WERED ACTUATED, <br />PINS. <br />FLEX . DUCT. <br />UP TO 29 <br />ROOF STRUCTURE <br />4-16d NAILS <br />THRU PLYWOOD <br />DUCT FROM UNIT --- <br />VO <br />4'" DEEP x 118" <br />WERED ACTUATED, <br />PINS. <br />1-1/2"WIDE x 26 GA <br />G. M. STRIP AT <br />SUPPORT. <br />DUCT HANG DETAIL <br />PROVIDE W/P. CAP LOW PROFILE <br />B.D.D. AT TOP FOR DRYER. <br />NO SCREEN FOR BATHROOM <br />PROVIDE INSECT SCREEN <br />TYPICAL ROOF CAP DETAIL <br />L O.A.I. AND/OR TOILET EXH. <br />NTS <br />N. T. S <br />FIELD COORDINATION NOTE <br />EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START <br />OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL <br />DETAILING AS PRE-FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION <br />OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, <br />SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ <br />ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALATION, NO ADDITIONAL COST <br />TO OWNER CAN BE APPLIED. <br />SCOPE OF WORK. <br />THIS JOB CONSIST OF INTERIOR REMODELING FOR EXISTING TENANT SPACE. HEAT LOAD CALCULATION HAVE BEEN DONE BECAUSE A <br />NEW LAYOUT, THE EXISTING 3 TONS RTU WILL BE USED (SEE SCHEDULE). NEW A/C DESIGN HAVE BEEN DONE AS APPEAR ON DWG. <br />RIGID QUCT UP <br />TO 29 WITH <br />OR 16 " DEEP. <br />1-1i 1-112" WIDTH x 26 GA <br />STRAP @ 8 "- 0 0/C <br />LOW VELOCITY <br />SUPPLY AIR DUCT <br />(SEE PLAN VIEW) E0* <br />METAL ROUND FITTING <br />QUADRANT OPERATOR <br />TO BE OUTSIDE INSULATION <br />PROVIDE INSULATION <br />GUARD WHERE NECESSARY <br />INSULATED FLEX. <br />(8'-0" MAXIMUM) <br />(THERMOFIN <br />PROVIDE 1" FIBERGLASS OR EQUAL) <br />INSULATION SEALED TO <br />TO NECK & PERIMETER <br />OF DIFFUSER <br />PERFORATED SEAL JOINT W/ <br />DIFFUSER DUCT S <br />k& TAPEEALER <br />FLEXIBLE DUCT <br />CONNECTION DETAIL <br />N.T.S. <br />ROOFTOP AIR CONDITIONING UNIT SCHEDULE. <br />MARK NO. <br />NEW RTU-1 <br />MODEL <br />7SC036A3E0A0A <br />TOTAL COOLING CAPACITY BTUH <br />36,000 <br />SENSIBLE COOLING CAPACITY BTUH <br />23,500 <br />SUPPLY AIR CFM <br />1,200 <br />ENTERING AIR TEMP. (DB/WB) <br />80/67 <br />OUTDOOR DESIGN TEMP. (DB) <br />95 <br />EXTERNAL STATIC PRESS. I N. W. G. <br />0.7 <br />ELECTRIC SERVICE <br />2081230130 <br />HEATING KW (BTUH) <br />7.5 <br />FUSE SIZE <br />30 AMPS <br />SEER <br />10.7 <br />DESIGN MFG. <br />TRANS <br />EXHAUST FAN SPECS I <br />NEW EF-1 "GREENHECK" MODEL SP 50 CFM <br />@1/4" WC, 115 VOLTS, 50 WATTS CEILING MOUNTED <br />W/B.D.D. BUILT-IN. <br />OUTSIDE AIR INTAKE CALCULATIONS AS PER <br />FBC 2010 & ASHRAE-62-1997. <br />O. A. I= # OF PERSON X CFM/PERSON + SQ. FT X CFM/SQ. FT <br />OFFICE AREA= 12 PERS X 7.0 CFM/PERS + 597 SF X 0.12 CFM/SQ.FT <br />= 156 CFM <br />RECEPTION AREA= 10 PERS X 5 CFM/PERS +314 SF X 0.06 CFM/SQ.FT <br />= 69 CFM <br />HALLWAY= 237 SF X 0.06 CFM/SQ.FT = 15 CFM <br />TOTAL O.A.1 CALCULATION = 240 CFM <br />400 CFM WILL BE PROVIDED <br />7An !`CAA <br />RTU #1 - - - = 20.0 <br />1200 CFM <br />HVAC DESIGN REQUIRE: <br />YES <br />NO <br />DUCT SMOKE DETECTOR <br />X <br />FIRE DAMPER(S) <br />X <br />SMOKE DAMPERS <br />X <br />FIRE RATE ENCLOSURE <br />X <br />FIRE RATED ROOF/FLOOR CEILING ASSEMBLY <br />X <br />FIRE STOPPING <br />X <br />SMOKE CONTROL <br />X <br />VACANT SPACE (7898) <br />1136 SF APPROX. <br />PS-1 <br />PS-1 <br />PS -1 <br />PS <br />TEST 150 CFM <br />() <br />150 CFM <br />PS-1 <br />CFM <br />BOOTH <br />(N) <br />225 CFM <br />(N) <br />6"0 <br />(N) <br />n <br />8 <br />TEST <br />8"0 <br />PS-1 <br />81)0 BOOTH <br />100 CFM <br />OX10 RAC <br />OX10 RAG <br />(N) 6„0 <br />AM <br />V.D V.D <br />V.D V.D <br />V.D PS-1 <br />° <br />8"X8" 1031X10" 12"X10" <br />10"X10" 225 CFM <br />I 1 <br />PS-1 V.D <br />50 CFM <br />PS-1 V.D �_,� -- V.D <br />100 CFM I <br />PS_1 V.D (N) <br />L� <br />(N) 4„0 <br />�X� , <br />(N) 6 I ► t <br />6 <br />„ <br />100 CFM 8 0 <br />O <br />PR, 1 <br />(N) <br />24 X24„ ---�--� <br />JERSEY MIKE'S SUBS <br />MECHANICAL P LAN S, NOTES AND DETAILS <br />SCALE: 1 /4"=l'-O" <br />CHANNEL SECTION <br />If Total Minimum Minimum <br />Extension is Channel Channel <br />not greater than: Gauge Profile <br />6" 24 3" X 1.5" <br />18" 22 3" X 2" <br />30" 18 3" X 2" <br />USE OF 2" WIDE <br />22 gauge 2'x 1.5" hangers may be substituted <br />for 3" hangers for ducts with widths not over 48" <br />and depths not over 24" provided that not more <br />than one joint occurs between hangers and the <br />maximum hanger spacing 4ft. Exception: When <br />duct perimeter is 80" or less and does not <br />require reinforcement two joints are permitted <br />between hangers <br />5 <br />STANDARD 3" WIDE HANGERS <br />Hanget extension to be the sum <br />of the distances between the hanging <br />wires and the duct size, ID (Smacna) <br />Duct size, Inches <br />Maximum Hanger <br />Spacing <br />48: Wide or grater <br />4 ft <br />Less tho 48" wide <br />Eft <br />and less than 48" <br />deep <br />Width between 28" <br />6ft <br />& 48" and greater <br />than 16" deep <br />Less than 29" wide <br />8ft <br />and 16 depth or less <br />HANGERS AND SUPPORTS <br />N. T. S. <br />MECHANICAL SYMBOL LEGEND <br />DENOTE 24X24 PS-1 <br />DENOTE RETURN AIR GRILL <br />24X24 PR-1 <br />5 <br />REVISIONS: <br />No./DATE: <br />No./DATE: <br />THESE DRAWING & SPECIFICATIONS ARE <br />INSTRUMENTS OF SERVICE AND SHALL <br />REMAIN THE PROPERTY OF MDS <br />ENGINEERING CORP. WHETHER THE <br />PROJECT FOR WHICH THEY WERE <br />PREPARED IS EXECUTED OR NOT, THEY <br />ARE NOT TO BE USED IN ANY MANNER <br />ON OTHER PROJECTS OR EXTENSIONS <br />TO THIS PROJECT EXCEPT BY <br />AGREEMENT IN WRITING AND WITH THE <br />APPROPRIATE COMPENSATION TO MDS <br />ENGINEERING CORP. IS PROHIBITED. <br />CONTRACTOR IS RESPONSIBLE FOR <br />VERIFYING ALL SITE CONDITION PRIOR <br />TO PROCEEDING WITH WORK. <br />—%®4 <br />a <br />l O • c) • "' <br />111 �' ••• ••c�� .A <br />' •• • % A <br />4� <br />I� <br />O Q <br />U <br />� o <br />o <br />Wow Q CD�Na <br />Z W v Q��00 <br />00 <br />Q m <br />►-� <br />Q� a-) � z <br />0 <br />DO CO <br />;1.4 N U 11 <br />F I <br />JOB No.: <br />DRAWN BY: M.D.S <br />SCALE: AS SHOW <br />MECHANICAL PLAN <br />mmi <br />SHEET 5 OF 7 <br />MDS ENGINEERING CORPORATION <br />