Laserfiche WebLink
PANEL L LOCATION ELEC 116 MTG SURFACE 125A BUS 125A MLO <br />MINIMUM INTEGRATED EQUIPMENT RATING 25,000A(RMS-SYM) 0 480V277 VOLTS 3 PHASE 4 WIRE <br />CIRC. <br />NO. <br />TRIP <br />AMPS <br />N0. <br />POLES <br />LOAD SERVED <br />- <br />LOAD/PHASE (VA) <br />LOAD SERVED <br />N0. <br />NO. <br />TRIP <br />AMPS <br />CIRC. <br />NO. <br />O <br />B <br />OA <br />OC <br />1 <br />20 <br />1 <br />SALES LIGHTING <br />1 080 <br />EXIT 0 <br />1 <br />20 <br />2 <br />3 <br />20 <br />1 <br />SALES LIGHTING <br />FRONT OFFICES/LOCKUP <br />1 <br />20 <br />4 <br />5 - <br />20 <br />1 <br />SALES LIGHTING <br />1584 <br />REAR OFFICES <br />NIGHTLIGHTS Q <br />1 <br />1 <br />20 <br />20 <br />6 <br />8 <br />7 <br />20 <br />1 <br />SALES LIGHTING <br />1 <br />4 <br />9 <br />20 <br />1 <br />SALES LIGHTING <br />SPARE <br />1 <br />20 <br />10 <br />11 <br />20 <br />1 <br />SALES LIGHTING <br />- <br />RECEIVING <br />SALES LIGHTING <br />1 <br />1 <br />20 <br />20 <br />12 <br />14 <br />13 <br />20 <br />1 <br />SALES LIGHTING <br />4 <br />' <br />1620 <br />__= <br />__ - <br />--- <br />-- <br />--- <br />_ <br />-- <br />15 <br />20 <br />1 <br />SALES LIGHTING <br />SALES LIGHTING <br />1 <br />20 <br />16 <br />17 <br />20 <br />1 <br />SALES LIGHTING <br />SPARE <br />1 <br />20 <br />18 <br />19 <br />20 <br />1 <br />SALES LIGHTING <br />SPARE <br />1 1 <br />20 <br />20 <br />21 <br />20 <br />1 <br />_ <br />SALES LIGHTING <br />SPARE <br />1 <br />20 <br />22 <br />23 <br />20 <br />1 <br />SPARE <br />SPARE <br />1 <br />20 <br />24 <br />25 <br />20 <br />1 <br />-_-- <br />SPARE <br />_ <br />SPARE <br />1 <br />20 <br />26 <br />27 <br />20 <br />1 <br />_- <br />SPARE <br />CANOPY LIGHTING <br />1 <br />20 <br />28 <br />29 <br />20 <br />1 <br />SPACE <br />EXTERIOR LIGHTING <br />1 <br />.20 <br />30 <br />31 <br />20 <br />1 <br />C <br />L T <br />1 <br />20 <br />32 <br />33 <br />20 <br />1 <br />SPACE <br />SPARE <br />1 <br />' 20 <br />34 <br />35 <br />20 <br />1 <br />Y <br />SPACE <br />SPARE <br />SPARE <br />1 <br />1 <br />20 <br />20 <br />36 <br />38 <br />37 <br />20 <br />1 <br />SPACE <br />--- <br />- - <br />39 <br />20 <br />1 <br />SPACE <br />SPARE <br />1 <br />20 <br />41 <br />20 <br />1 <br />SPACE <br />SPARE <br />1 <br />20 <br />_40 <br />42 <br />2 3 6 6 1 - <br />TOTAL CONNECTED LOAD: 41.5 kVA CONNECTED AMPS: 50 <br />---_ TOTAL DESIGN LOAD: 51.8 kVA _ _ DESIGN AMPS: 62 <br />4R SAVVY IP PANEL <br />_UDING SAVVY BASE <br />ATE, RELAYS, CPT'S <br />& REC.) <br />MATT STOPPER —SW <br />FACTOR, 48 RELAYS, <br />CHANNEL, 48 CAP. <br />,LUDES 48 RELAYS) <br />NOVAR PHASE LOSS <br />MONITOR <br />TRANSIENT VOLTAGE <br />URGE SUPPRESSOR- <br />(TVSS) <br />LEFT SIDE VIEW <br />T-1 <br />XFMR <br />112.5KVA <br />PANEL MDP LOCATION ELEC 116 MTG SURFACE, TOPFED 400A BUS 400A MCB W/ST <br />MINIMUM INTEGRATED EQUIPMENT RATING 25,000A(RMS-SYM) Q 480Y/277 VOLTS 3 PHASE 4 WIRE <br />CIRC. <br />NO. <br />TRIP <br />AMPS <br />N0. <br />POLES <br />LOAD SERVED <br />LOAD PHASE VA <br />/ ( ) <br />LOAD SERVED <br />NO. <br />POLES <br />TRIP <br />AMPS <br />CIRC. <br />NO. <br />-- <br />OA <br />Og <br />OC <br />1 <br />175 <br />3 <br />XFMR T-1 10 <br />7 <br />SPACE <br />3 <br />250 <br />2 <br />_ <br />SPACE - <br />- <br />- - <br />- <br />SPACE <br />RTU-2 ® <br />- <br />3 <br />-- <br />30 <br />4 <br />3 <br />30 <br />3 <br />RTU-1 <br />- <br />74 28 <br />RTU-4 ® <br />3 <br />30 <br />✓� <br />5 <br />30 <br />3 <br />RTU-3 Q <br />-- <br />7 <br />1 30 <br />3 <br />RTU-6 3U <br />RTU-5 (7 <br />3 <br />15 <br />8 <br />BALER <br />3 <br />30 <br />10 <br />9 <br />15 <br />3 <br />PHASE LOSS MONITOR <br />-- <br />-- <br />�--- - <br />--- <br />- <br />- <br />38 7 <br />11 <br />30 <br />3 <br />SPACE <br />--- <br />__= <br />SPACE <br />3 <br />30 <br />12 <br />-- <br />- <br />SPACE <br />SPACE <br />- <br />-- <br />-- <br />- <br />- <br />SPACE <br />- -- <br />SPACE <br />- <br />-- <br />13 <br />125 <br />3 <br />PANEL "L" +,� <br />_ <br />13=-- <br />_ _ <br />SPACE <br />3 <br />250 <br />14 <br />- <br />- -- <br />SPACE` <br />- <br />-- <br />-- <br />- <br />--- <br />SPACE <br />- <br />-- <br />9225Z 92323 94797 TOTAL. THIS PANEL <br />TOTAL CONNECTED LOAD: 279kVA CONNECTED AMPS:323 <br />� TOTAL DESIGN LOAD: 255 kVA SERVICE ENTRANCE RATED DESIGN AMPS: 307 <br />,7 <br />11� <br />I � ■■1 <br />--�At 0 <br />P2 P1 <br />250A 150A <br />MCB MCB <br />208/120V o <br />30, 4W <br />I 1-i- 08/120V <br />EMS 1 30, 4w <br />CABINET <br />L_--J <br />r L <br />1 F.. I MLO <br />�1 -� a <br />1 125A 480/277 <br />r 30, 4W <br />Tm <br />--LA <br />0 <br />V30A <br />FRONT VIEW <br />TRANSFORMER TO SHIP UNINSTALLED <br />(SECONDARY FEEDERS, WIREWAY <br />& FITTINGS FACTORY PROVIDED. <br />E.C. TO SET CONNECT ONLY) <br />MDP <br />400A MCB <br />480/277V <br />30, 4W <br />(SERVICE ENTRANCE) <br />75.5 H X 31 W <br />2�INTEGRATED SWITCH BOARD DETAIL <br />E-1 )NOT TO SCALE <br />BUILDING EXTERIOR <br />2 SETS, 4-4/0 <br />& #3 G.-3"C. <br />ENGINEER/E.C. TO VERIFY WITH <br />UTILITY COMPANY FOR LOCATION <br />SIZE AND REQUIREMENTS FOR CT <br />AND CABINET INSTALLATION <br />INCLUDING FINAL CONNECTIONS. - <br />METER SOCKET BY E.C. IN <br />ACCORDANCE WITH UTILITY CO. <br />STANDARDS <br />ENGINEER/E.C. TO VERIFY WITH <br />UTILITY COMPANY FOR <br />INSTALLATION REQUIREMENTS, r <br />INCLUDING FINAL CONNECTIONS. <br />CONCRETE PAD <br />FINISH GRADE- <br />'11 6 <br />1 1 /2 "C (COORD <br />W/UTILITY CO.) — <br />DALL TYPICAL RTU <br />REMOVABLE <br />TOP —LIFT <br />PROVISIONS <br />TO CT CABINET <br />(BY E.C.) <br />KWH <br />TRANSDUCER <br />INSTALLED <br />INSIDE <br />CAN BY HP. <br />PANELPI LOCATION ELEC 116 MTG SURFACE 225A BUS 150A MCB <br />MINIMUM INTEGRATED EQUIPMENT RATING 10,000A(RMS-SYM) (2 208Y/ 120 VOLTS 3 PHASE 4 WIRE <br />FRONT VIEW <br />TRANSFORMER TO SHIP UNINSTALLED <br />(SECONDARY FEEDERS, WIREWAY <br />& FITTINGS FACTORY PROVIDED. <br />E.C. TO SET CONNECT ONLY) <br />MDP <br />400A MCB <br />480/277V <br />30, 4W <br />(SERVICE ENTRANCE) <br />75.5 H X 31 W <br />2�INTEGRATED SWITCH BOARD DETAIL <br />E-1 )NOT TO SCALE <br />BUILDING EXTERIOR <br />2 SETS, 4-4/0 <br />& #3 G.-3"C. <br />ENGINEER/E.C. TO VERIFY WITH <br />UTILITY COMPANY FOR LOCATION <br />SIZE AND REQUIREMENTS FOR CT <br />AND CABINET INSTALLATION <br />INCLUDING FINAL CONNECTIONS. - <br />METER SOCKET BY E.C. IN <br />ACCORDANCE WITH UTILITY CO. <br />STANDARDS <br />ENGINEER/E.C. TO VERIFY WITH <br />UTILITY COMPANY FOR <br />INSTALLATION REQUIREMENTS, r <br />INCLUDING FINAL CONNECTIONS. <br />CONCRETE PAD <br />FINISH GRADE- <br />'11 6 <br />1 1 /2 "C (COORD <br />W/UTILITY CO.) — <br />DALL TYPICAL RTU <br />REMOVABLE <br />TOP —LIFT <br />PROVISIONS <br />TO CT CABINET <br />(BY E.C.) <br />KWH <br />TRANSDUCER <br />INSTALLED <br />INSIDE <br />CAN BY HP. <br />PANELPI LOCATION ELEC 116 MTG SURFACE 225A BUS 150A MCB <br />MINIMUM INTEGRATED EQUIPMENT RATING 10,000A(RMS-SYM) (2 208Y/ 120 VOLTS 3 PHASE 4 WIRE <br />CIRC, <br />NO. <br />TRIP <br />AMPS <br />NO. <br />POLES <br />LOAD SERVED <br />LOAD/PHASE (VA) <br />LOAD SERVED <br />NO. <br />POLES <br />TRIP <br />AMPS <br />CIRC. <br />NO, <br />OA <br />OB <br />OC <br />1 <br />20 <br />1 <br />EWC <br />1140 <br />1,00 <br />-� ¢ 1 <br />QR <br />168 E <br />1080 - <br />1720 <br />-� 80 <br />_ <br />1232 - <br />1 <br />- <br />_ <br />3�0 50 <br />GONDOLA LIGHTING <br />1 <br />20 <br />2 <br />3 <br />20 <br />1 <br />RECEPTACLES <br />GONDOLA LIGHTING <br />1 <br />20 <br />4 <br />5 <br />0 <br />1 <br />WH-1 <br />GONDOLA LIGHTING <br />1 <br />20 <br />6 <br />7 <br />0 <br />1 <br />SPARE <br />GONDOLA LIGHTING <br />1 <br />20 <br />8 <br />9 <br />^lL <br />GONDOLA LIGHTING <br />1 <br />20 <br />10 <br />11 <br />20 <br />1 <br />VENDING <br />GONDOLA LIGHTING <br />1 <br />20 <br />12 <br />13 <br />20 <br />1 <br />VENDING <br />GONDOLA LIGHTING <br />1 <br />20 <br />14 <br />15 <br />20 <br />1 <br />RECEPT/BUZZER <br />RIGHT SIGN (IF USED) <br />1 <br />20 <br />16 <br />17 <br />20 <br />1 <br />TRAINING <br />LEFT SIGN (IF USED) <br />1- <br />20 <br />18 <br />19 <br />20 <br />1 <br />RCVG DESK RECEPT <br />FRONT SIGN <br />1 <br />20 <br />20 <br />21 <br />20 <br />1 <br />TEF-1 <br />RECEPTACLES <br />! <br />20 <br />22 <br />23 <br />20 <br />1 <br />— <br />SAT. TV <br />SPARE <br />1 <br />20 <br />24 <br />25 <br />20 <br />1 <br />LOUNGE REFRIG. <br />DOT COM RECEPTACLES <br />1 <br />20 <br />26 <br />27 <br />20 <br />1 <br />RECEPTACLE SATELLITE <br />SPARE <br />I20 <br />28 <br />29 <br />20 <br />1 <br />ROOF RECEPTACLES <br />SPARE <br />20 <br />30 <br />31 <br />20 <br />1 <br />SOUND SECURITY SYS 10 <br />SCISSOR LIFT 1 <br />20 <br />32 <br />33 <br />20 <br />1 <br />FACP180 <br />EC RM EC PT <br />1 <br />20 <br />34 <br />35 <br />20 <br />1 <br />EMS XFMR Q <br />TELE/COMM RM RECPT 10 <br />1 <br />20 <br />36 <br />37 <br />20 <br />1 <br />EMS XFMR 11 <br />SPARE <br />1 <br />20 <br />38 <br />39 <br />20 <br />1 <br />LV RACK 10 <br />TELE/COMM RM RECPT 11 <br />1 <br />20 <br />40 <br />41 <br />20 <br />1 <br />EXIT DOOR HARDWARE i'J400 <br />SPARE <br />1 <br />20 <br />42 <br />11344 12148 12344 TOTAL THIS PANEL <br />TOTAL CONNECTED LOAD: 23.7 kVA CONNECTED AMPS: 66 <br />TOTAL DESIGN LOAD: 25.6 kVA DESIGN AMPS: 72 <br />POWERPLUS INTEGRATED SWITCHBOARD PACKAGE GENERAL NOTES: <br />1. THE ELECTRICAL GEAR PACKAGE WILL BE PURCHASED BY CONTRACTOR & SUPPLIED BY HILL PHOENIX. THE <br />FOLLOWING ITEMS WILL BE INCLUDED IN THE ELECTRICAL GEAR PACKAGE - POWERPLUS INTEGRATED SWITCHBOARD, <br />LOOSE PANELS, KWH TRANSDUCERS, RTU DISCONNECTS, BALER DISCONNECT / FUSES, & SPARE FUSE CABINET <br />WITH SPARE FUSES. THE POWERPLUS INTEGRATED SWITCHBOARD WILL BE UL LISTED AND CONTAIN THE FOLLOWING <br />FACTORY INSTALLED, WIRED, AND TESTED EQUIPMENT - PANELBOARDS, LIGHTING RELAY PANEL, TRANSFORMER, <br />TVSS, PLM, AND NOVAR EMS EQUIPMENT. THE ELECTRICAL CONTRACTOR (E.C.) SHALL CONTACT HILL PHOENIX AT <br />(770) 285-3251, FAX (770) 285-3252 OR E-MAIL edpstoples©hillphoenix.com TO OBTAIN A DETAILED QUOTE, <br />BILL OF MATERIAL, AND PRODUCT DRAWING DURING BID TIME. <br />2. E.C. IS RESPONSIBLE FOR VERIFICATION OF THE AVAILABLE FAULT CURRENT FROM THE UTILITY COMPANY (IS <br />THE SYSTEM AS DESIGNED ACCEPTABLE??). E.C. TO CONTACT LOCAL UTILITY COMPANY REPRESENTATIVE AND <br />OBTAIN THE AVAILABLE FAULT CURRENT AND/OR THE UTILITY TRANSFORMER KVA SIZE AND IMPEDANCE. <br />PROVIDE THIS INFORMATION TO HILL PHOENIX TO DETERMINE SYSTEM REQUIREMENTS. SYSTEMS AVAILABLE <br />ARE 25K, 35K or 65K AIC - SEE HILL PHOENIX QUOTATION ADDER OPTIONS. E.C. SHALL INCLUDE THE FINAL <br />SYSTEM REQUIRED IN THEIR BID (INCLUDE ADDER $$$ IF REQUIRED). <br />3. E.C. IS RESPONSIBLE TO GIVE HILL PHOENIX A SIX (6) WEEK WRITTEN REQUEST (MIN.) OF THE REQUIRED <br />ONSITE PACKAGE DELIVERY DATE. USE CONTACT INFORMATION SUPPLIED IN #1 NOTE ABOVE. <br />4. THE POWERPLUS INTEGRATED SWITCHBOARD SHALL BE DELIVERED AS A SINGLE WALL WITH NO SHIPPING <br />SPLITS. THIS INSURES THAT ALL INTERNAL CONDUCTORS ARE TERMINATED PROPERLY AND NO EXTRA FIELD <br />LABOR IS REQUIRED TO MOUNT AND RE -CONNECT CABINET SECTIONS OR TO RE -CONNECT COILED UP <br />CONDUCTORS. NOTE: THE TRANSFORMER WILL SHIP LOOSE FOR E.C. TO SET, SECURE ON UNIT PAD, AND MAKE <br />FINAL CONNECTIONS AS REQUIRED. FEEDERS, WIREWAY, AND FITTINGS WILL BE FURNISHED WITH UNIT. <br />5. E.C. IS RESPONSIBLE TO RE -TORQUE ALL FACTORY WIRED CONNECTIONS UPON DELIVERY OF THE <br />POWERPLUS INTEGRATED SWITCHBOARD (AS CONNECTIONS COULD HAVE LOOSENED DURING <br />SHIPMENT) <br />6. E.C. WILL BE RESPONSIBLE FOR OFFLOADING AND SETTING OF THE POWERPLUS INTEGRATED SWITCHBOARD ONCE IT <br />ARRIVES AT THE JOB SITE. E.C. SHALL BE RESPONSIBLE FOR STORING UNIT IN A DRY LOCATION AS REQUIRED IF <br />THE UNIT IS DELIVERED BEFORE BUILDING IS WEATHERED IN. THERE WILL BE PROVISIONS TO LIFT THE INTEGRATED <br />SWITCHBOARD FROM BOTH THE FRONT AND SIDE. THIS WILL FACILITATE OFFLOADING AND SETTING OF THE UNIT. <br />TYPICAL TIME FOR OFFLOADING AND SETTING IS APPROXIMATELY 2 HOURS. <br />7. E.C. IS TO CONTACT HILL PHOENIX TO OBTAIN SITE SPECIFIC PRODUCT DRAWINGS. HILL PHOENIX WILL <br />PROVIDE A FINAL PRODUCT DESIGN PACKAGE TO THE SUCCESSFUL E.C. SO ACCURATE ROUGH -IN <br />COORDINATION (STUB -UPS) CAN BE COMPLETED. <br />8. AT TIME OF BID, E.C. SHALL BE RESPONSIBLE FOR REVIEWING THE HILL PHOENIX QUOTATION (ESPECIALLY <br />THE OPTIONS) AND INCLUDE THE OPTIONS AS REQUIRED PER LOCAL CODES. THESE OPTIONS CAN INCLUDE AN <br />EXTERIOR SHUNT TRIP BUTTON, AN EXTERIOR FUSIBLE DISCONNECT SWITCH WITH A MLO MDP, AND OTHER <br />ITEMS LISTED. E.C. SHALL INCLUDE THE ADDER DOLLARS AS REQUIRED. <br />NOTES: <br />1. APPROX WT: 2400 LBS. (W/O XFMRS) — — — — — — = "DASHED" FEEDERS ARE <br />2. ENCLOSURE FINISH: PROVIDED/INSTALLED BY ELECTRICAL <br />G90 GALVANIZED STEEL CONTRACTOR. <br />3. PRODUCT LAYOUT (MDP ON RIGHT) WILL BE MAINTAINED. ="SOLID" FEEDERS ARE <br />THIS APPLIES TO LEFT & RIGHT HAND STORE LAYOUTS. FACTORY WIRED <br />THE CT CABINAT SHALL ALWAYS BE MOUNTED TO RIGHT <br />OF THE MDP. <br />NF/N3R NF/N3R NF/N3R NF/N3R NF/N3R <br />30/3P 30/3P 30/3P 30/3P 30/3P <br />480V, 30 RTU-1 480V, 30 RTU-2 480V, 30 RTU-3 480V, 30 RTU-4 480V, 30 <br />RTU-6 F F TF F F <br />3-#8 & 1-#10G, 1 "C. <br />UTILITY <br />COMPANY <br />ENGINEER/E.C. TO PAD MOUNTED <br />VERIFY WITH UTILITY TRANSFORME { <br />UIRE <br />FOR PR(MARYMENTS FEEDER I <br />4"C. SPARE <br />STAPLES SPACE <br />4-#10 & 1-#10G.-3/4"C. <br />PHASE LOSS MONITOR <br />BY STAPLES (SEE 3/E-7) - <br />3-#8 & 1-#10G, 1 "C. �-- 3-#8 & 1-#10G, 1 "C. -- 3-#8 & 1-#10G, 1 "C <br />' PLM1 <br />ITO E.M.S. <br />EXECUTIVE —� <br />CONTROLLER <br />IWIRED BY E.M.S. <br />-1 <br />SEE SITE SPECIFIC <br />STRUCTURAL DRAWINGS <br />FOR RTU LOCATIONS <br />3-#8 & 1-#10G, 1 "C. <br />NF/N3R <br />30/3P <br />480V, 30 <br />RTU-5 <br />- 3-# 10 & 1-# 10G, 3/4"C. <br />3-#8 & 1-#10G.-1 "C. <br />-- -- -- -- -- -- -- -- -- -- -- -- --� <br />4-#1 & 1-#6G. 2"C. 4-#1 /0, 1-#6G. & 1-#61G.-2 1 /2"C. I <br />1 <br />F_ -1 f------- - — — — — - F------ — <br />I I I I F—LS <br />I SJ <br />PANEL LIGHTING I PANEL PANELI L Pi P2 <br />I <br />1480/277VAC1 ( CONTROL I I208/120VAC 1 1208/120VAC I 9 <br />I I I IPANELI I I I <br />I l I I 0 I I I PROVIDE DOUBLE I I F <br />I I I I LUGS ON XFMR 1 <br />I I I I I I I SECONDARY <br />— — — — I I 30/3/30 <br />I� � I I � O <br />T I I I I I wP <br />I SRATEDE I J 150A.) MB. I I I I 250 MB. <br />L__—_ J L____ J i TRANSFORMER � LJ�_l -#4G, &4250KCMIL,I3" CONDUITS T-1BALER <br />FOR CONTROLLED 112.5 KVA 1-#41G.-3"C. <br />CIRCUITS 4-#1/0 & 1-#6G.-1 1/2"C. (D I 1 <br />/.--3-#3/0 & 1-#6G.-2"C. I 1 3 1 <br />��__-�/� 1-#1/0-1" C. <br />� � 1 <br />1 1 <br />2 SETS, 4-4/0- 3"C. 1 1 <br />(480/277V, 30, 4W-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --� <br />SECONDARY SERVICE) <br />90° CONDUIT SWEEPS (TYPICAL) ONE LINE ®IAG RAM SEE INTEGRATED SWITCH <br />BOARD DETAIL THIS SHEET. <br />E-1 NOT TO SCALE <br />14� (TYP.) <br />4-#1, 1-#6G., 1-#61G. <br />2 1 /2"C. <br />DUAL LUGS <br />PANEL <br />P3 <br />208/120VAC <br />125A <br />PANEL P2 LOCATION ELEC '116 MTG SURFACE 400A BUS 250 A MCB <br />MINIMUM INTEGRATED EQUIPMENT RATING i 0,000A(RMS-SYM) Q 208V 120 VOLTS 3 PHASE 4 WIRE <br />CIRC. <br />NO. <br />TRIP <br />AMPS <br />NO. <br />POLES <br />LOAD SERVED <br />LOAD/PHASE (VA) <br />LOAD SERVED <br />NO. <br />POLES <br />TRIP <br />AMPS <br />CIRC, <br />NO. <br />-- <br />OA <br />---- <br />OB <br />--- <br />OC <br />1 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />f44 <br />An I HiE <br />1 - <br />1 <br />KIM <br />14 <br />4� _ <br />1 <br />144 <br />1 <br />1 <br />10880 <br />720 <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />2 <br />3 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />4 <br />5 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />6 <br />7 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />8 <br />9 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />10 <br />11 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />12 <br />13 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />14 <br />15 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />16 <br />17 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />18 <br />19 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />20 <br />21 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />22_ <br />23 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />24 <br />25 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />26 <br />27 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />28 <br />29 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />30 <br />31 <br />SURGE SUPPRESSOR <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />32 <br />33 <br />30 <br />3 <br />SURGE SUPPRESSOR 1 <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />34 <br />35 <br />SURGE SUPPRESSOR 0 <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />36 <br />37 <br />PANEL "P3"/"P4" <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />38 <br />39 <br />125 <br />3 <br />PANEL "P3"/"P4" <br />GONDOLA RECEPTACLE <br />1 <br />20 <br />40 <br />41 <br />PANEL "P3"/"P4" <br />SPARE <br />1 <br />20 <br />42 <br />PROVIDE SEPARATE ISOLATED GROUND BUS 25310 265iO 25530 TOTAL THIS PANEL <br />TOTAL CONNECTED LOAD: 77.4 kVA CONNECTED AMPS: 215 <br />TOTAL DESIGN LOAD: 50.3 kVA _ DESIGN AMPS: 140 <br />PANEL P3 LOCATION LOCKUP 105 MTG FLUSH, TOPFED 125A BUS 125A MLO <br />MINIMUM INTEGRATED EQUIPMENT RATING 10,000A(RMS-SYM) Q2 208Y/ 120 VOLTS 3 PHASE 4 WIRE <br />CIRC. <br />NO. <br />TRIP <br />AMPS <br />NO. <br />POLES <br />LOAD SERVED <br />LOAD/PHASE (VA) <br />LOAD SERVED <br />NO. <br />POLES <br />TRIP <br />AMPS <br />CIRC. <br />NO. <br />OA <br />OB <br />OC <br />1 <br />20 <br />1 <br />CASH REG RECEPT <br />360 <br />188 <br />1440 ___ <br />1 <br />--- <br />CASH REGISTER D <br />1 <br />20 <br />2 <br />3 <br />20 <br />1 <br />RECEPT/CASH OFFICE <br />CASH REGISTER <br />1 <br />20 <br />4 <br />5 <br />20 <br />1 <br />RECEPT/CASH OFFICE <br />CASH REG RECEPT 10 <br />1 <br />20 <br />6 <br />7 <br />20 <br />1 <br />RECEPT/CASH OFFICE <br />SPARE <br />1 <br />20 <br />8 <br />9 <br />20 <br />1 <br />RECEPT/MGMT OFFICE <br />CASH REGISTER D <br />1 <br />20 <br />10 <br />11 <br />20 <br />1 <br />MGMT/CASH/LOCK-UP <br />CASH REGISTER 0 <br />1 <br />20 <br />12 <br />13 <br />20 <br />1 <br />SPARE <br />CCTV 10 <br />1 <br />20 <br />14 <br />15 <br />15 <br />1 <br />RECEPT/SERVICE <br />CCTV 0 <br />1 <br />20 <br />16 <br />17 <br />15 <br />1 <br />NETWORK PRINTER <br />BURGLAR ALARM 0 <br />1 <br />20 <br />18 <br />19 <br />15 <br />1 <br />RECEPT/VESTIBULE <br />EAS 10 <br />1 <br />20 <br />20 <br />21 <br />15 <br />1 <br />SODA MACHINES <br />AUTOMATIC DOOR <br />1 <br />20 <br />22 <br />23 <br />20 <br />1 <br />LOCK -UP RECEPT <br />AUTOMATIC DOOR <br />1 <br />20 <br />24 <br />25 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />AUTOMATIC DOOR <br />1 <br />20 <br />26 <br />27 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />28 <br />29 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />30 <br />31 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />32 <br />33 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />34 <br />35 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />36 <br />37 <br />20 <br />1 <br />1 GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />38 <br />39 <br />20 <br />1 <br />GONDOLA RECEPTACLE <br />SPARE <br />1 <br />20 <br />40 <br />41 <br />20 <br />1 <br />SPARE <br />SPARE <br />1 <br />20 1 <br />42 <br />PROVIDE SEPARATE ISOLATED GROUND BUS 3020 2980 3240 ITOTAL THIS PANEL <br />TOTAL CONNECTED LOAD: 29.1 kVA CONNECTED AMPS: 81 <br />TOTAL DESIGN LOAD: 19.6 kVA DUAL LUGS DESIGN AMPS:54.4 <br />PANEL P4 LOCATION LOCKUP 105 MTG FLUSH, TOPFED 125A BUS 125A MLO <br />MINIMUM INTEGRATED EQUIPMENT RATING 10,000A(RMS-SYM) Q2 208Y/ 120 VOLTS 3 PHASE 4 WIRE <br />CIRC. <br />NO. <br />TRIP <br />AMPS <br />NO. <br />POLES <br />LOAD SERVED <br />LOAD/PHASE (VA) <br />LOAD SERVED <br />NO. <br />POLES <br />TRIP <br />AMPS <br />CIRC. <br />NO. <br />OA <br />O B <br />O C <br />1 <br />20 <br />1 <br />COPY CTR RECEPT <br />360 <br />539 <br />OPI <br />wd <br />180 1 <br />Rp <br />--- <br />--- <br />--- <br />--- <br />--- <br />=_= <br />CASH REGISTER 0 <br />1 <br />20 <br />2 <br />3 <br />20 <br />1 <br />COPY CTR RECEPT <br />CASH REGISTER 1Q <br />1 <br />20 <br />4 <br />5 <br />20 <br />1 <br />CASH REGISTER 10 <br />WIDE FORMAT COLOR COPIER <br />1 <br />20 <br />6 <br />7 <br />20 <br />1 <br />FAX MACHINE <br />LAMINATOR <br />1 <br />20 <br />8 <br />9 <br />20 <br />1 <br />COPIER RECEPT <br />WIDE FORMAT COPIER <br />1 <br />20 <br />10 <br />11 <br />20 <br />2 <br />HIGH SPEED COPIER <br />SELF -SERVE COPIER <br />1 <br />20 <br />12 <br />13 <br />-- <br />- <br />HIGH SPEED COPIER <br />SELF -SERVE COPIER <br />1 <br />20 <br />14 <br />15 <br />20 <br />1 <br />COPIER (FUTURE) <br />SELF -SERVE COPIER <br />1 <br />20 <br />16 <br />17 <br />20 <br />1 <br />COPIER (FUTURE) <br />SELF SERVE COPIER <br />1 <br />20 <br />18 <br />19 <br />20 <br />1 <br />COPIER RECEPT <br />COLOR COPIER <br />1 <br />20 <br />20 <br />21 <br />20 <br />1 <br />COPY CTR RECEPT <br />DEDICATED REC (FUTURE) <br />1 <br />20 <br />22 <br />23 <br />20 <br />1 <br />COPY CTR SWITCH <br />DEDICATED REC (FUTURE) <br />1 <br />20 <br />24 <br />25 <br />20 <br />1 <br />POSS SYSTEM <br />SPACE AND BUS <br />1 <br />20 <br />26 <br />27 <br />20 <br />1 <br />SELF SERVE RECEPT <br />SPACE AND BUS <br />1 <br />20 <br />28 <br />29 <br />1 20 <br />1 <br />COPIER RECEPTS <br />SHREDDER (FUTURE) <br />1 <br />20 <br />30 <br />31 <br />20 <br />1 <br />SPACE AND BUS <br />SPACE AND BUS <br />1 <br />20 <br />32 <br />33 <br />20 <br />1 <br />SPACE AND BUS <br />SPACE AND BUS <br />1 <br />20 <br />34 <br />35 <br />20 <br />1 <br />SPACE AND BUS <br />SPACE AND BUS <br />1 <br />20 <br />36 <br />37 <br />20 <br />1 <br />SPACE AND BUS <br />SPACE AND BUS <br />1 <br />20 <br />38 <br />39 <br />20 <br />1 <br />SPACE AND BUS <br />SPACE AND BUS <br />1 <br />20 <br />40 <br />41 <br />20 <br />1 <br />SPACE AND BUS <br />SPACE AND BUS <br />1 <br />20 <br />42 <br />PROVIDE SEPARATE ISOLATED GROUND BUS 5050 7190 7730 ITOTAL THIS PANEL <br />TOTAL CONNECTED LOAD: 19.9 kVA CONNECTED AMPS: 55 <br />TOTAL DESIGN LOAD: 19.9 kVA DESIGN AMPS: 55 <br />PANEL <br />P4 <br />208/120VAC <br />125A <br />FINISHED FLOOR <br />NOTES BY SYMBOL: <br />U PROVIDE TRIP FREE HANDLE LOCK DEVICE ON CIRCUIT BREAKER. <br />E.C. SHALL VERIFY ACTUAL AVAILABLE SHORT CIRCUIT <br />CURRENT. DOWNSTREAM OVERCORRECT PROTECTION SHALL <br />BE FULLY RATED WITH DEVICES IN "MDP" WHERE ALLOWED <br />BY CODE. SEE POWERPLUS INTEGRATED SWITCHBOARD <br />PACKAGE GENERAL NOTES #2 FOR ADDITIONAL <br />INFORMATION/REQUIRMENTS. <br />�3 PROVIDE HACR RATED BREAKER FOR SERVICE TO RTU. <br />ELECTRICAL LOAD ANALYSIS <br />SERVICE VOLTAGE: 480Y/2.77- ---jAREA: 20,053 SF <br />OCCUPANCY: STAPLES, INC.; RETAIL STORE <br />LOAD DESCRIPTION <br />CONNECTED LOAD (VA) <br />DIVERSITY % <br />DESIGN LOAD (VA) <br />REMARKS <br />LIGHTING <br />62539 - <br />125 <br />78174 <br />RECEPTACLES <br />NEC 220-13 <br />43800 <br />MOTORS - -� <br />_77600 <br />13099 <br />100 <br />13099 <br />_ <br />25% OF LARGEST MOTOR <br />�(11,619) <br />25 <br />2905 <br />BALER <br />HVAC - COOLING - <br />128864 <br />100 <br />128864 <br />_ <br />HVAC - HEATING <br />10150 <br />0 <br />0 <br />—� <br />GENERAL <br />- <br />15500 <br />- <br />100 <br />15500 <br />SIGNS & SITE LTG <br />19044 <br />1_25 <br />23805 <br />TOTAL LOAD _ <br />326796� <br />- _ <br />__ <br />306147 <br />_ v <br />TOTAL AMPS <br />393 <br />RELAY SCHEDULE <br />RELAY PANEL LOAD PROGRAM NOVAR INPUT LOW VOLTAGE <br />NO. CKT DESCRIPTION INPUT RELAY SWITCH CONTROL <br />R1 <br />L-1 <br />SALE AREA PROGRAM <br />A <br />NR1 <br />SLV1 <br />R2 <br />L-7 <br />SALE AREA PROGRAM <br />A� <br />NR1 <br />SLV1 <br />R3 <br />L-9 <br />SALE AREA PROGRAM <br />A <br />NR1 <br />SLV1 <br />R4 <br />L-14 <br />SALE AREA PROGRAM <br />A <br />NR1 <br />SLV1 <br />R5 <br />L-15 <br />SALE AREA PROGRAM <br />A <br />NR1 <br />SLV1 <br />R6 <br />L-17 <br />SALE AREA PROGRAM <br />A <br />NR1� <br />SLV1 <br />R7 <br />L-23 <br />SALE AREA PROGRAM <br />A <br />NR1 <br />SLV1 <br />R8 <br />SPARE <br />R9 <br />L-3 <br />SALE AREA PROGRAM <br />B <br />NR2 <br />SLV2 <br />Rl0 <br />L-5 <br />SALE AREA. PROGRAM <br />B <br />NR2 <br />SLV2 <br />Rll <br />L-11 <br />SALE AREA PROGRAM <br />_ <br />B <br />NR2 <br />SLV2 <br />R12 <br />L-13 <br />SALE AREA PROGRAM <br />B <br />NR2 <br />SLV2 <br />R13 <br />L-16 <br />SALE AREA PROGRAM <br />B <br />NR2 <br />SLV2 <br />R14 <br />L-21 <br />SALE AREA PROGRAM <br />B <br />NR2 <br />SLV2 <br />R15 <br />SPARE <br />R 16 <br />L-19 <br />FURNITURE FOCAL LTG. <br />C <br />NR3 <br />SLV3 <br />R1 7 <br />P1-2 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R18 <br />P1-4 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R19 <br />P1-6 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R20 <br />P1-8 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R21 <br />P1-10 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R22 <br />P1-12 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R23 <br />P1-14 <br />GONDOLA LIGHTING <br />C <br />NR3 <br />SLV3 <br />R24 <br />P1-28 <br />LAMP DISPLAY OUTLET <br />C <br />NR3 <br />SLV3 <br />R25 <br />P1-30 <br />LAMP DISPLAY OUTLET <br />C <br />NR3 <br />SLV3 <br />R26 <br />SPARE <br />R27 <br />L-4 <br />FRONT OFFICE LIGHTS <br />D <br />NR4 <br />SLV4 <br />R28 <br />L-6 <br />REAR OFFICE LIGHTS <br />D <br />NR4 <br />SLV4 <br />R29 <br />L-12 <br />RECEIVING AREA <br />D <br />NR4 <br />SLV4 <br />R30 <br />P1-21 <br />TEF-1 <br />D <br />NR4 <br />SLV4 <br />R32 <br />NOT USED <br />R33 <br />NOT USED <br />R35 <br />P1-22 <br />SPARE <br />F <br />NR5 <br />SLV5 <br />R37 <br />NOT USED <br />R38 <br />NOT USED <br />R40 <br />SPARE <br />R42 <br />NOT USED <br />R43 <br />NOT USED <br />R45 <br />SPARE <br />R46 <br />L-30 <br />EXT. WALL PACK LTG <br />H <br />NR7 <br />SLV7 <br />R47 <br />L-32 <br />EXT. WALL PACK LTG <br />H <br />NR7 <br />SLV7 <br />R48 <br />SPARE <br />RELAY SCHEDULE NOTES: <br />RELAY PANEL SHALL BE WATTSTOPPER, HUBBELL OR GENERAL ELECTRIC <br />48 RELAY TUB WITH ISOLATED PILOT CONTACTS, ACCESSORY DEVICE <br />POWER TAP, 120 VOLT POWER SUPPLY, EEPROM MEMORY, MECHANICAL <br />LATCHING 20 AMP., 277 VOLT RELAYS, ACCESSORY MOUNTING PLATE, <br />INDIVIDUAL RELAY CONTROL BUTTONS, PROGRAMMABLE INPUT CHANNEL <br />AND MOUNTING BRACKET. PANEL PROVIDED AS PART OF THE ELECTRICAL <br />DISTRIBUTION SYSTEM PACKAGE. <br />LIGHT FIXTURE CIRCUITING PROGRAM: <br />PROGRAM A - 50% SALES AREA OVERHEAD LIGHTING PRIOR TO OPENING <br />PROGRAM B - 50% SALES AREA OVERHEAD LIGHTING AT OPENING <br />PROGRAM C - SALES AREA GONDOLA FURNITURE LIGHTS AT OPENING. <br />PROGRAM D - LIGHTS @ OFFICES NIGHT LIGHT CIRCUIT <br />PROGRAM E - NOT USED <br />PROGRAM F - SIGN LIG <br />PROGRAM G - CANOPY <br />PROGRAM H - WALL PA 7L <br />ONE LINE DIAGRAM NOTES BY SYMBOL: <br />OPROVIDE FERRAZ SHAWMUT CURRENT LIMITING FUSES UL CLASS J TIME DELAY 200,000 <br />AIC AJT (600 V) OR USE MAIN CIRCUIT BREAKER WITH MIN. 65,000 AIC. <br />COORDINATE WITH LOCAL AUTHORITY. FUSES PROVIDED BY HILL PHOENIX. <br />BOND NEUTRAL OF XFMR SECONDARY TO THE XFMR CASE WITH BONDING JUMPER SIZE <br />2 DE <br />IN ACCORDANCE WITH NEC TABLE 250-94. <br />OGROUND THE CASING OF XFMR, SECONDARY NEUTRAL, AND ISOLATED GROUND <br />CONDUCTOR, TO THE NEAREST EFFECTIVELY GROUNDED STRUCTURAL STEEL MEMBER <br />OF THE BLDG. OR CLOSEST WATER PIPE. SIZE OF GROUNDING CONDUCTOR TO BE <br />IN ACCORDANCE WITH NEC TABLE 250-94. <br />O4 #2/OCU.-GRD. IN 3/4"C. TO STREET SIDE OF WATER METER AND BUILDING STEEL. <br />5OTHREE SELF-CONTAINED SPLIT -CORE KWH TRANSDUCER METERS (PULSE OUTPUT) <br />INSTALLED AROUND SERVICE WIRES WITH BUILT IN FUSED HOLDER AND WIRE LEADS <br />FOR CONNECTION TO PANEL BUS OR LUGS. TRANSDUCERS TO BE LOCATED IN MDP <br />BY HILL PHOENIX, FINAL INSTALLATION BY E.C. PULSE OUTPUT WIRING BY E.M.S <br />CONTRACTOR. MAY BE ORDERED FROM: VERIS INDUSTRIES INC. TEL. (800)-354-8556 <br />HAWKEYE SERIES TRANSDUCERS #H8053-0400-3 FOR 400A. SERVICES. <br />OBOND METER SOCKET TO THE SERVICE ENTRANCE GROUND OR NEUTRAL AS PER <br />NEC 250-94. <br />0 #2/OCU.-GRD. TO 3/4" X 10'-0" LONG COPPER CLAD STEEL GROUND ROD (BY E.C.) <br />ALL CONNECTIONS TO BE EXOTHERMIC WELD. <br />(DROOF TOP UNIT HEAVY DUTY WP DISCONNECT SWITCH, SHALL BE FURNISHED BY HILL <br />PHOENIX AND INSTALLED BY ELECTRICAL CONTRACTOR SIZE AS NOTED. WP., GFI SERVICE <br />OUTLET PROVIDED WITH ROOF TOP UNIT AND WIRED (CIRCUIT P1-29) BY ELECTRICAL s, <br />CONTRACTOR. B � <br />O208/12OV.,30 TRANSIENT VOLTAGE SURGE SUPPRESSOR. d$te <br />HUBBELL CAT. NO. HBL4W100. , <br />r <br />10 LIGHTING CONTROL PANEL PROVIDED AS PART OF ELECTRICAL DISTRIBUTION <br />SYSTEM PACKAGE. <br />11 METER SOCKET AS REQUIRED BY UTILITY CO. <br />12 ELECTRICAL DISTRIBUTION EQUIPMENT SEE SPECIFICATIONS MANUAL FOR INFORMATION <br />13 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE EQUIPMENT <br />PURCHASED FROM ANY SOURCE, INCLUDING THROUGH STAPLES' <br />NATIONAL ACCOUNT PROGRAMS. ALL ELECTRICAL DISTRIBUTION <br />EQUIPMENT SHALL BE ORDERED FOR IMMEDIATE SHIPMENT UPON <br />RECEIPT OF CONTRACT TO AVOID POTENTIAL DELAYS. SUBSTITUTIONS OR <br />CHANGES IN EQUIPMENT MAKE, MODEL, OR SPECIFICATIONS WITHOUT <br />DIRECT WRITTEN AUTHORIZATION FROM STAPLES' ARE NOT ALLOWED. <br />14 ALL POWER CONNECTIONS TO RTU SHALL BE UP THROUGH RTU CURB ENCLOSURE. <br />4-.4 W, <br />u <br />w <br />VC:8 0 <br />Y <br />� o <br />w <br />Q) <br />U <br />u <br />e <br />V <br />W <br />O <br />Q <br />0 <br />V <br />N +� Cc: <br />L to M c <br />U <br />^, <br />Wca J 0 <br />Lu <br />cc �- ca <br />0) aLL <br />-Em <br />L > <br />�cMI-(A <br />w <br />J <br />U <br />.O <br />_(D <br />0- <br />cu <br />-0--+ <br />U) <br />I <br />cn <br />c <br />O <br />E <br />E <br />O <br />U <br />SL <br />N <br />N <br />}/0 <br />Cu cn <br />cr)/J u c <br />coo <br />8U � !�. w <br />0 <br />m ca <br />Y N 0- <br />a <br />00 <br />N -, <br />cn p <br />�� <br />f� <br />Qo p <br />t U <br />a <br />`z u <br />�., v 3 <br />v , <br />LLJ <br />0 <br />W <br />U <br />J <br />LL! <br />z <br />Q <br />0 <br />z <br />Q <br />I <br />Q <br />0 <br />W <br />z <br />J <br />W <br />wz <br />OH <br />w <br />w <br />cn <br />C= m <br />LU <br />c� w <br />OG <br />uj <br />0n <br />w` <br />C r) D <br />r w <br />w <br />cn <br />z <br />R <br />iy <br />z <br />w <br />C <br />N�s <br />0 <br />0 <br />d <br />�� <br />w <br />Dl <br />co, <br />� <br />p <br />o <br />uJ <br />[V <br />N <br />a <br />zrn <br />UJ <br />cc <br />N <br />a <br />W <br />h <br />o <br />E 1 <br />