PVC WASTE LINE <br />LENGTH TO SUIT <br />BRONZE CLEANOUT PLUG <br />W/COUNTER SUNK HEAD <br />FINISHED GRADE <br />16" SQUARE CONCRETE PAD. <br />TWO WAY CLEANOUT R&G SLOAN PVC <br />PART NO.3724 <br />WASTE LINE <br />Exterior Cleanout Detail (ECO) <br />SCALE:NTS <br />_I_ L <br />\\8-1 ') B 2 ,( B-3) B-4 1 f,\ B-5 ; B-6�B-7 �} B-8 B 9 �B 10 (B-11) <br />REAR <br />LEFT RIGHT 1 Plumbing Floor Plan <br />NScale 1/8"=1'-0" <br />FRONT <br />PLUMBING EQUIPMENT SCHEDULE <br />MARK <br />EQUIPMENT <br />MANUFACTURER <br />MODEL# <br />PIPE SIZE <br />DESCRIPTION <br />DESCRIPTION <br />CW <br />HW <br />WASTE -VENT <br />CO-1 <br />EXTERIOR 2-WAY <br />ZURN <br />ZN-1400-HD <br />_ <br />- <br />SEE PLANS <br />HEAVY TRAFFIC AREA EXTERIOR CLEANOUT WITH ACCESS <br />CLEAN -OUT <br />HEAVY TRAFFIC <br />COVER AND TWO-WAY FITTING. SEE PLAN FOR PIPE SIZE <br />CONNECTION. <br />BRASS HOSE BIBB WITH POLISHED CHROME FINISH, <br />HB-1 <br />HOSE BIBB <br />WOODFORD <br />B24 <br />3/4" <br />- <br />_ <br />VANDAL PROOF VACUUM BREAKER BACK FLOW <br />PREVENTER, 3/4-INCH MALE HOSE THREAD, WHEEL <br />HANDLE ENCLOSED IN BRASS CASTING CHROME PLATED <br />LOCKING RECESSED BOX OPERATED BY LOOSE KEY. <br />PIPING MATERIAL SCHEDULE <br />SERVICE <br />SIZE <br />MATERIAL <br />SCHEDULE/TYPE <br />INSULATION <br />REMARKS <br />TYPE <br />THICK <br />DOMESTIC COLD WATER <br />ALL <br />COPPER <br />TYPE L <br />FG <br />1" <br />ALL SERVICE JACKETS <br />SANITARY BELOW GRADE <br />ALL <br />C.I.OR PVC <br />SERVICE WEIGHT <br />NONE <br />-- <br />NO HUB <br />SANITARY ABOVE SLAB <br />ALL <br />C.I.OR PVC <br />SERVICE WEIGHT <br />NONEA <br />- <br />NO HUB <br />I <br />NOTES: <br />1. WASTE AND VENT PIPING IN OFFICE PLUNUM SPACE SHALL BE SERVICE WEIGHT CAST IRON, NO HUB. <br />PLUMBING GENERAL NOTES <br />1. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES AND GOVERNING AUTHORITIES. I.E.=FLORIDA BUILDING CODE 2004 - PLUMBING. <br />2. ALL SANITARY PIPING SHALL HAVE A 1/8" PER FOOT SLOPE UNLESS OTHERWISE NOTED. ALL STORM WATER PIPING SHALL HAVE A 1/8" <br />PER FOOT, MINIMUM, HORIZONTAL SLOPE UNLESS OTHERWISE INDICATED. <br />3. VALVES AND FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY ARE LOCATED, UNLESS OTHERWISE INDICATED ON DRAWINGS. <br />4. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING AND <br />PENETRATIONS. <br />5. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN SIZING. <br />6. CHANGES IN THE DIRECTION OF SANITARY AND STORM DRAIN PIPING SHALL NOT BE MADE WITH FITTINGS WHICH WILL CAUSE <br />EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER ADVERSE EFFECT (IE: USE OF SANITARY TEE IN A <br />HORIZONTAL CONNECTION, USE OF A DOUBLE SANITARY TEE IN A VERTICAL STACK, IN GENERAL, USE OF SHORT -RADIUS FITTINGS FOR <br />BRANCH TO HOUSE DRAIN OR STACK CONNECTION). <br />7. CONTRACTOR SHALL GIVE 24 HOURS NOTICE TO APPLICABLE UTILITY COMPANY PRIOR TO PERFORMING WORK INVOLVING UTILITIES. <br />8. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION FOUNDATION. <br />9. WHERE SANITARY SEWER LINES CROSS UNDERGROUND WATER SUPPLY LINES WITH LESS THAN 8" MINIMUM VERTICAL CLEARANCE, THE <br />SANITARY SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (10' EACH SIDE OF WATER MAIN) OR THE WATER LINES SHOULD BE <br />MODIFIED TO PROVIDE 8" MINIMUM CLEARANCE. <br />10. THE PLUMBING CONTRACTOR MAY BE REQUIRED TO DROP PIPE OUTSIDE OF BUILDING TO REQUIRED DEPTH TO PROVIDE CONNECTION <br />TO AREA DEVELOPMENT UTILITY STUB. ALL DROPS IN DEPTH SHALL BE MADE BY THE USE OF 45' FITTINGS. <br />11. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. EXPOSED PIPING SHALL BE SLOPED AND PAINTED TO <br />MATCH ARCHITECTURAL FINISHES AND SHALL BE INSTALLED TIGHT TO MASONRY WALL. PIPING IN MECHANICAL ROOMS MAY BE EXPOSED. <br />12. SLEEVE AND FIRE STOP ALL PENETRATIONS (IF ANY) OF RATED WALLS, FLOORS, CEILINGS, ETC., IN ACCORDANCE WITH APPLICABLE UL <br />STANDARDS AND LOCAL CODES TO MAINTAIN RATINGS. REFER TO SPECIFICATIONS AND ARCHITECTURAL DRAWINGS FOR RATED <br />WALLS, CEILINGS AND FLOORS INFORMATION. <br />13. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE PLACED ON THE INTERIOR SIDE OF THE WALL. THE WALL INSULATION SHALL <br />BE PLACED ON THE EXTERIOR SIDE OF THE PIPING. ANY PIPING INSTALLED IN UNCONDITIONED SPACES SHALL BE INSULATED AND <br />PROTECTED FROM FREEZING TEMPERATURES. <br />14. SPACES SHALL BE INSULATED AND PROTECTED FROM FREEZING TEMPERATURES. SEE RISER DIAGRAMS FOR BRANCH PIPING DETAILS <br />AND SIZES NOT SHOWN ON PLAN. <br />15. COLD WATER PIPING SHALL BE COPPER WATER TUBE (ASTM 888) TYPE "L" WITH WROUGHT -COPPER (ANSI B16.22), OR CAST BRASS (ANSI <br />B16.18) PRESSURE FITTINGS AND ALLOY GRADE (ANSI-ASTM B32) 95TA LEAD-FREE SOLDER JOINTS. DISINFECT WATER PIPING AFTER <br />PRESSURE TEST WITH CHLORINE SOLUTION 50 MG-L) FOR 24 HOURS. FLUSH LINES CLEAN AFTER COMPLETION. <br />16. PROVIDE CLEANOUTS AS FOLLOWS: <br />(A) AT BASE OF EACH VERTICAL STACK INCLUDING BACK. <br />(B) AT EACH CHANGE OF DIRECTION OF HORIZONTAL RUNS <br />(C) AT 75 FOOT INTERVALS OF HORIZONTAL RUNS. <br />17. METERING AND SITE UTILITY CONNECTIONS SHALL BE PROVIDED ON SITE UTILITY DRAWINGS. ALL SERVICES SHOWN ON THIS SET OF <br />PLANS TERMINATE 5'-0" FROM BUILDING, UNLESS SHOWN OTHERWISE ON DRAWINGS. PLUMBING CONTRACTOR SHALL MAKE FINAL <br />CONNECTIONS TO SITE UTILITES. <br />18. FURNISH AND INSTALL HOSE BIBBS AND/OR WALL HYDRANTS 24" ABOVE FINISHED GRADE/FLOOR AND PROVIDE VACUUM BREAKERS. <br />19. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ROOF DRAINS. <br />20. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE TO BE CONNECTED BEFORE <br />INSTALLATION OF NEW SEWER LINE. <br />21. ALL VENTS THROUGH ROOF SHALL BE MIN. 10'-0" FROM ANY AIR INTAKES. <br />22. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS. <br />23. CONTRACTOR SHALL ROUGH -IN ALL WASTES AND SUPPLIES TO SPECIAL EQUIPMENT ACCORDING TO MANUFACTURER'S SHOP <br />DRAWINGS AND MAKE FINAL CONNECTIONS, ALL SUPPLIES SHALL BE VALVED. INSTALL VACUUM BREAKERS WHERE REQUIRED BY CODE. <br />24. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (INCLUDING PIPE ROUTING AND EQUIPMENT LOCATIONS) TO ARCHITECT/ENGINEER FOR <br />REVIEW PRIOR TO THE INSTALLATION OR PURCHASING OF ANY PIPING AND/OR EQUIPMENT. <br />25. ALL BELOW GRADE -SLAB COPPER PIPE SHALL BE PLACED WITHIN COPPER PIPE SLEEVE (10 MIL) POLYETHYLENE PLASTIC SLEEVING. <br />EXTEND SLEEVING ABOVE GRADE/SLAB. <br />26. PRESSURE REDUCING VALVES SHALL BE INSTALLED ON BRANCH LINES SERVING FIXTURES AND/OR EQUIPMENT, WHEN THE PRESSURE <br />IN THE LINE EXCEEDS 80 P.S.I. <br />27. WHEN THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS NOT CLEAR, OR IS CAPABLE OF MORE THAN ONE INTERPRETATION, SUCH <br />MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS. THE <br />ARCHITECT/ENGINEER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. <br />28. PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED. ALL ITEMS NOT SPECIFICALLY <br />MENTIONED OR SHOWN, BUT NECESSARY FOR THE COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY THIS <br />CONTRACTOR. THIS CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE MECHANICAL, ARCHITECTURAL, STRUCTURAL AND <br />ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED DUE TO THE CONTRACTOR'S <br />FAILURE TO FAMILIARIZE HIMSELF WITH THE PLANS. <br />29. THE CONTRACTOR SHALL BASE HIS PROPOSAL UPON THE EQUIPMENT AS SCHEDULED OR SPECIFIED, USING THE MANUFACTURER'S AND <br />MODEL NUMBERS AS CALLED FOR IN THE SPECIFICATIONS AND SCHEDULED ON THE DRAWINGS. IF MORE THAN ONE MANUFACTURER OF <br />EQUIPMENT IS SPECIFIED, ANY ONE OF THE MANUFACTURER'S OF EQUIPMENT MAY BE USED IN THIS CONTRACTOR'S PROPOSAL. IF THIS <br />CONTRACTOR WISHES TO USE EQUIPMENT NOT SPECIFIED HE MUST, AT THE TIME OF BIDDING, SUBMIT SEPARATELY ON LETTERHEAD <br />STATIONARY OF THE BIDDER, THE EQUIPMENT HE WOULD SUBSTITUTE AND THE COST TO BE ADDED OR TO BE DEDUCTED FROM HIS <br />PROPOSAL. <br />30. THE CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. <br />DELAY IN DELIVERIES WILL NOT BE CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE MATERIALS. <br />31. DO NOT PENETRATE WALL FOOTINGS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP FOOTINGS AS REQUIRED TO <br />CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE <br />SLEEVED AND LOCATION APPROVED BY STRUCTURAL ENGINEER. <br />32. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS FOR DOMESTIC WATER SUPPLY CONNECTIONS AS REQUIRED BY CODE.. <br />PLUMBING LEGEND <br />DESCRIPTION <br />ABBREV. <br />SYMBOL <br />SANITARY PIPING ABOVE SLAB <br />SAN <br />SANITARY PIPING BELOW SLAB <br />SAN <br />- - <br />COLD WATER PIPING <br />CW <br />- - <br />HOT WATER PIPING <br />HW <br />- - - - - - <br />SHUT-OFF VALVE <br />- - ----- i6H- - - <br />FLOOR CLEANOUT <br />FCO <br />-0 <br />CLEAN OUT TO GRADE <br />COTG <br />IN -LINE OR WALL CLEAN OUT <br />COMCO <br />CAP <br />C - <br />TEE UP <br />--�-- <br />TEE DOWN- <br />90° UP <br />- - - <br />90° DOWN <br />- <br />HOSE BIBB <br />HB <br />-}}- <br />TYPICAL <br />(TYP) <br />DRAWING LIST <br />NO. <br />TITLE <br />P001 <br />Plumbing Floor Plan, Notes, Schedules & Details <br />Key Plan <br />-- Kossik Rd <br />i <br />........... <br />�X <br />1 US Hwy 301 <br />x <br />i <br />a <br />U <br />W <br />C <br />0 <br />CL <br />0 <br />V <br />(U Nc ao <br />co <br />m <br />.LOCCMC <br />U <br />/1 ♦ U <br />�V <br />w <br />� <br />� � co <br />LL <br />a <br />z <br />a) <br />'� 0) C> <br />w <br />�(N0� <br />M H fn <br />J <br />U <br />Cn <br />C <br />O <br />E <br />E <br />0 <br />U <br />L <br />C_ <br />cl'o <br />co <br />N <br />(U U_ <br />En =)�0 <br />LLJ <br />06sU <br />��c <br />v <br />-0Oa)ca <br />o <br />m Y N 0- <br />a <br />.00 <br />0 <br />06 <br />U <br />U) <br />Q) <br />A--r <br />0 <br />z <br />CC <br />n <br />L <br />O <br />_O <br />LL <br />w EJ <br />H <br />w <br />w <br />co <br />LLi <br />46.o- <br />w <br />z <br />�. <br />W N <br />w <br />A <br />co <br />Yo <br />to <br />LC <br />a w <br />__. <br />„1 IL <br />w <br />O <br />Z <br />0 <br />U) <br />U) <br />m <br />U) <br />F_ <br />M <br />Of <br />W <br />C� <br />0 <br />W <br />�CD <br />J <br />W <br />Q' <br />d <br />Z <br />rn <br />o <br />F-CD <br />W <br />-� <br />M <br />p <br />N <br />w <br />M <br />o <br />Z <br />Uj <br />he <br />U <br />LU <br />Pool <br />