GENERAL NOTES: <br />1. BUILDING AND DESIGN CODES: <br />A. 2020 FLORIDA BUILDING CODE <br />B. AISC 360-16: SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS <br />(1 5 EDITION STRUCTURAL STEEL MANUAL) <br />C. S100-16: NORTH AMERICAN SPECIFICATION <br />FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS <br />D. AWS STRUCTURAL STEEL WELDING CODE, D1.1-2020 <br />E. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL <br />CONCRETE <br />F. ACI DETAILING MANUAL, 2004 <br />G. STRUCTURAL WELDED WIRE REINFORCEMENT MANUAL OF <br />STANDARD PRACTICE, WIRE REINFORCEMENT INSTITUTE, 2011 <br />H. TMS 402 - 2016 BUILDING CODE FOR MASONRY STRUCTURES <br />I. CRSI MANUAL OF STANDARD PRACTICE, 2009 <br />J. SDI RD - 2017 STANDARD FOR STEEL ROOF DECK <br />2. DESIGN LOADS: <br />A. LIVE LOADS: <br />UNIFORM <br />ROOF <br />20 PSF <br />SLAB ON GRADE <br />100 PSF <br />LIVE LOAD REDUCTION ON SUPPORTING <br />ELEMENTS IN ACCORDANCE WITH, <br />BUILDING CODE <br />B. DEAD LOADS: <br />ROOF DEAD LOAD <br />12 PSF <br />C. WIND LOADS: <br />3 SECOND GUST WIND SPEED: <br />Vult = 138 MPH (Vasd = 107 MPH) <br />EXPOSURE: <br />C <br />RISK CATEGORY: <br />II <br />D. SEISMIC LOADS: <br />SEISMIC IMPORTANCE FACTOR: 1.00 <br />OCCUPANCY CATEGORY: II <br />Ss: SPECTRAL ACC FOR SHORT PERIOD = 0.058g <br />Si: SPECTRAL ACC FOR 1 SECOND PERIOD = 0.032g <br />SITE CLASS D <br />SDS: DESIGN SPECTRAL ACC FOR SHORT PERIOD= 0.062g <br />SDI: DESIGN SPECTRAL ACC FOR 1 SECOND PERIOD= 0.51 g <br />SEISMIC DESIGN CATEGORY A <br />Fa = 1.6 <br />Fv = 2.4 <br />BASIC SEISMIC FORCE RESISTING SYSTEM: STRUCTURAL STEEL NOT <br />SPECIFCALLY DETAILED FOR SEISMIC RESISTANCE <br />DESIGN BASE SHEAR = 2.4 KIPS <br />Cs = 0.01 <br />R = 3.0 <br />SEISMIC DESIGN PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE <br />:M101190751 toy-3 . <br />Ce: EXPOSURE FACTOR = 1.0 <br />Cr: THERMAL FACTOR = 1.0 <br />Pg = GROUND SNOW LOAD = 0 PSF <br />F. ADDITIONAL DESIGN LOADS (ASD) INDICATED ON STRUCTURAL <br />DRAWINGS SHALL BE IDENTIFIED AS FOLLOWS: <br />DL = DEAD LOAD <br />LL = LIVE LOAD <br />WL = WIND LOAD <br />EL = SEISMIC LOAD <br />3. GENERAL REQUIREMENTS: <br />A. SPECIFICATIONS ARE PART OF THE CONSTRUCTION DOCUMENTS AND MUST BE USED <br />IN CONJUNCTION WITH THE DRAWINGS. <br />B. VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK OR <br />FABRICATING MATERIALS. NOTIFY A/E OF DISCREPANCIES BEFORE PROCEEDING WITH <br />ANY PHASE OF WORK. <br />C. VERIFY THE LOCATION OF CHASES, INSERTS, OPENINGS, SLEEVES, FINISHES, <br />DEPRESSIONS, PADS, AND WALL OPENINGS. <br />D. DO NOT SCALE DRAWINGS FOR THE PURPOSE OF ESTABLISHING DIMENSIONS. <br />E. DETAILS LABELED "TYPICAL DETAILS" ON DRAWINGS APPLY TO SITUATIONS <br />OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY <br />DETAILED. SUCH DETAILS APPLY WHETHER OR NOT DETAILS ARE REFERENCED AT EACH <br />LOCATION. NOTIFY ENGINEER OF CONFLICTS REGARDING APPLICABILITY OF <br />"TYPICAL DETAILS". <br />F. DO NOT LOAD THE SLAB ON GRADE OR SUPPORTED SLAB WITH ERECTION CRANES OR <br />ERECTION EQUIPMENT. THE SLABS HAVE NOT BEEN DESIGNED FOR CRANE LOADS AND <br />WILL REQUIRE AN INCREASE IN THICKNESS AND/OR REINFORCEMENT. OBTAIN A/E <br />APPROVAL ON PROPOSED CRANE SUPPORT PLAN FOR SLABS PRIOR TO COMMENCING WORK. <br />G. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON POURED OR ERECTED <br />FLOORS/ROOFS IN EXCESS OF 80 PERCENT OF LIVE LOAD. GENERAL CONTRACTOR WILL <br />ENSURE THAT ALL SUB -CONTRACTORS ARE INFORMED OF LOADING RESTRICTIONS. <br />AVOID IMPACT WHEN PLACING MATERIALS ON POURED OR ERECTED FLOORS OR ROOF. <br />H. THE CONTRACT STRUCTURAL DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THE <br />CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. <br />PROVIDE ALL MEASURES REQUIRED TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER <br />PERSONS DURING CONSTRUCTION; INCLUDING BRACING, SHORING FOR CONSTRUCTION <br />EQUIPMENT, SHORING FOR THE BUILDING, FORMS AND SCAFFOLDING, SHORING OF <br />RETAINING WALLS AND OTHER TEMPORARY SUPPORTS AS REQUIRED. COMPLY WITH <br />APPLICABLE REQUIREMENTS OF OSHA AND OTHER GOVERNING BODIES HAVING <br />JURISDICTION AT THE SITE. <br />1. PRINCIPAL OPENINGS THROUGH THE FRAMING ARE SHOWN ON DRAWINGS. EXAMINE THE <br />ARCHITECTURAL AND MECHANICAL DRAWINGS FOR THE REQUIRED OPENINGS AND PROVIDE <br />FOR REQUIRED OPENINGS WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT, <br />VERIFY SIZE AND LOCATION OF OPENINGS WITH THE MECHANICAL CONTRACTOR. <br />DEVIATIONS FROM THE OPENINGS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE <br />APPROVED PRIOR TO IMPLEMENTING THE CHANGES. <br />J. LOADINGS FOR MECHANICAL EQUIPMENT ARE BASED ON THE UNITS SHOWN ON THE <br />MECHANICAL DRAWINGS. ANY CHANGES IN TYPE, SIZE, OR NUMBER OF PIECES OF <br />EQUIPMENT SHALL BE REPORTED TO THE ARCHITECT FOR VERIFICATION OF THE <br />ADEQUACY OF SUPPORTING MEMBERS PRIOR TO THE PLACEMENT OF SUCH EQUIPMENT. <br />K. SEE ARCHITECTURAL DRAWINGS FOR ELEVATIONS NOT SHOWN AND FOR EXACT LOCATIONS <br />OF ALL SLAB DEPRESSIONS. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL <br />SECTIONS WITH ARCHITECTURAL SECTIONS AND REPORT ANY DISCREPANCY <br />TO THE ARCHITECT PRIOR TO FABRICATING OR INSTALLING STRUCTURAL MEMBERS. <br />FOUNDATION: <br />FOUNDATION DESIGN IS BASED UPON THE GEOTECHNICAL ENGINEERING REPORT ENTITLED <br />"GEOTECHNICAL EXPLORATION" DOLLAR GENERAL ZEPHYRHILLS NEC OF US 301 & C AVENUE, <br />ZEPHYRHILLS, FLORIDA PREPARED BY UNIVERSAL ENGINEERING SCIENCES DATED FEBRUARY 25, <br />2021 <br />1. CONTRACTOR TO PROVIDE FOUNDATION & FOOTING AS REQUIRED FOR PYLON SIGN OR <br />MONUMENTAL SIGN REF. SPECIFICATIONS <br />2. COORDINATE STRUCTURAL PLANS AND DETAILS WITH REQUIREMENTS OF GEOTECHNICAL <br />REPORT FOOTING DESIGN IS BASED ON 2500 PSF SOIL BEARING PRESSURE. <br />3. CONTRACTOR SHALL TREAT SOIL BELOW SLAB FOR TERMITES PER 2020 FBC SECTION <br />18164. <br />4. REFER TO THE GEOTECHNICAL REPORT AND SPECIFICATIONS FOR GENERAL REQUIREMENTS <br />OF EARTHWORK, OVEREXCAVATION, SUBGRADE PREPARATION, FILL AND COMPACTION, <br />WATERPROOFING AND OTHER PERTINENT REQUIREMENTS AND INFORMATION. IF THERE IS <br />A CONFLICT BETWEEN GEOTECHNICAL REPORT AND STRUCTURAL PLANS THEN THE MORE <br />STRINGENT CRITERIA SHALL APPLY UNLESS OTHERWISE DIRECTED BY AN RFI. <br />5. PROTECT PIPES AND CONDUITS RUNNING THROUGH WALLS AND SLABS WITH 1/2 INCH <br />EXPANSION MATERIAL. LOWER CONTINUOUS FOOTINGS AND GRADE BEAMS PERPENDICULAR <br />TO PIPE RUNS TO ALLOW PIPES TO PASS ABOVE THE FOOTINGS OR THROUGH THE GRADE <br />BEAMS. ALTERNATIVELY, PROVIDE A CONCRETE JACKET IF PIPES ARE LOW ENOUGH TO <br />BE PLACED BELOW THE FOOTINGS AND GRADE BEAMS. LOWER FOOTINGS AND GRADE BEAMS <br />PARALLEL TO PIPE RUNS TO AVOID SURCHARGE ONTO ADJACENT TRENCH EXCAVATIONS. <br />6. MAINTAIN SUBGRADE AND FILL MOISTURE CONTENT UNTIL FOUNDATIONS ARE PLACED. <br />7. ARRANGE FOR OWNER'S INDEPENDENT TESTING AGENCY TO MONITOR CUT AND FILL <br />OPERATIONS AND PERFORM FIELD DENSITY AND MOISTURE CONTENT TESTS TO VERIFY <br />COMPACTION AND APPROVE FOOTING SUBGRADES PRIOR TO PLACING CONCRETE. <br />8. DO NOT PLACE FOOTINGS OR SLABS AGAINST SUBGRADE CONTAINING FREE WATER, FROST, <br />OR ICE. <br />9. MAINTAIN PROPER SITE DRAINAGE DURING CONSTRUCTION TO ENSURE SURFACE RUNOFF <br />AWAY FROM STRUCTURES AND TO PREVENT PONDING OF SURFACE RUNOFF NEAR THE <br />STRUCTURES. <br />PAD PREPARATION: <br />RE: GEOTECH REPORT <br />1 . PROVIDE BATCH MIXING, TRANSPORTATION, PLACING AND CURING OF CONCRETE IN <br />ACCORDANCE WITH RECOMMENDATIONS OF ACI 301 AND ACI 318. USE ASTM C 150 <br />CEMENT UNLESS NOTED OTHERWISE. PROVIDE ADMIXTURES AND SPECIAL REQUIREMENTS <br />AS SPECIFIED. <br />A. COMPLY WITH ACI 301 REQUIREMENTS FOR CONCRETE MIXTURES. <br />B. CONCRETE MIX DESIGN(S) SHALL BE PROPORTIONED ACCORDING TO ACI <br />301, FOR NORMAL -WEIGHT CONCRETE DETERMINED BY EITHER LABORATORY <br />TRIAL MIX OR FIELD TEST DATA AS FOLLOWS: <br />1. COMPRESSIVE STRENGTH (28 DAYS): 4000PSI (27.6MPA), WITH A <br />MAXIMUM WATER/CEMENT RATIO OF .53, UNLESS OTHERWISE INDICATED <br />ON THE DRAWINGS. CONCRETE MATERIALS INCLUDED IN THE MIX <br />DESIGN SHALL BE THE SAME MATERIALS PROVIDED TO THE PROJECT, <br />AND SHALL BE PREPARED BY AN INDEPENDENT TESTING LABORATORY <br />APPROVED BY THE OWNER. IF SUFFICIENT BACKUP DATA IS NOT <br />AVAILABLE, THE LABORATORY MIX DESIGN SHALL EXCEED THE DESIRED <br />JOB STRENGTH OF CONCRETE BY 1,200PSI. FOUR COPIES OF THE MIX <br />DESIGN SHALL BE SUBMITTED TO THE OWNER BEFORE CONCRETE <br />WORK BEGINS. <br />2. SLUMP: CONCRETE CONTAINING MID OR HIGH RANGE WATER REDUCER <br />SHALL HAVE A MAXIMUM SLUMP OF 5'/" FOR THE INTERIOR SALES FLOOR <br />SLAB AND 8" (200 MM) FOR OTHER AREAS. ALL OTHER CONCRETE SHALL <br />NOT EXCEED 4 INCHES (100 MM UNLESS OTHERWISE INDICATED ON THE <br />DRAWINGS. <br />3. ADJUSTMENT TO CONCRETE MIXES: MIX DESIGN ADJUSTMENTS MAY BE <br />REQUESTED BY GENERAL CONTRACTOR WHEN CHARACTERISTICS OF <br />MATERIALS, JOB CONDITIONS, WEATHER, TEST RESULTS OR OTHER <br />CIRCUMSTANCES WARRANT; AT NO ADDITIONAL COST TO OWNER AND AS <br />ACCEPTED BY OWNER. LABORATORY TEST DATA FOR REVISED MIX DESIGN <br />AND STRENGTH RESULTS MUST BE SUBMITTED TO AND ACCEPTED BY <br />OWNER BEFORE USING IN WORK. BOTH THE CONCRETE TESTING AND <br />INSPECTION AGENCY AND THE CONCRETE CONTRACTOR SHALL SATISFY <br />THEMSELVES THAT THE CONCRETE MIX DESIGN WILL PRODUCE A <br />CONCRETE WHICH WILL MEET THE SPECIFICATIONS FOR THIS PROJECT. <br />IN ADDITION, THE GENERAL CONTRACTOR AND CONCRETE CONTRACTOR <br />SHALL VERIFY THAT THE WORKABILITY, FINISHABILITY AND SETTING TIMES <br />ARE APPROPRIATE FOR SLAB INSTALLATIONS. PLACEMENT SHALL BE MADE <br />DIRECTLY FROM CONCRETE TRUCKS BY CHUTE. IF PUMPING OF THE <br />CONCRETE IS CONTEMPLATED FOR ANY SPECIAL LOCATIONS, THE <br />PROPORTIONS ESTABLISHED ABOVE SHALL NOT BE ALTERED TO SUIT THE <br />CAPABILITIES OF THE PUMPING EQUIPMENT. FOR CONCRETE CONTAINING <br />MACRO -SYNTHETIC FIBERS, ADJUSTMENTS REQUIRED TO PROVIDE <br />REQUIRED PLACEMENT CONDITIONS MAY WARRANT USE OF ADDITIONAL <br />WATER REDUCER. NO ADDITIONAL WATER IS PERMITTED INTO CONCRETE <br />MIXTURE AFTER ADDITION OF MACRO -SYNTHETIC FIBERS. <br />4. INTERIOR CONCRETE SALES FLOOR: CONCRETE SHALL BE DESIGNED TO <br />MEET 4000 PSI COMPRESSIVE STRENGTH @ 28 DAYS AND EXHIBIT < 0.04% <br />SHRINKAGE @ 28 DAYS. THE MIX SHALL CONTAIN APPROXIMATELY 12 CUBIC <br />FEET OF #467 AGGREGATE (1-1/2" TOP SIZE), THE SPECIFIED WATER <br />REDUCING ADMIXTURE AND ACHIEVE A W/CM RATIO OF 0.53 (MAX.). <br />CONCRETE SHALL BE NON AIR -ENTRAINED AND IN NO CASE SHALL THE <br />CONCRETE BE DESIGNED FOR LESS THAN 4000 PSI (27.6MPA) @ 28 DAYS. <br />PROPOSED MIX DESIGN SHALL BE SIMILAR TO THE FOLLOWING <br />PROTOTYPE MIX: <br />MATERIALS MIX AMOUNTS <br />CEMENT 517-564LBS. <br />FLY ASH/SLAG PROHIBITED <br />COARSE AGGREGATE 12 CUBIC FEET +/- .50 (#467 STONE) <br />FINE AGGREGATE 7 CUBIC FEET +/- (ADJUST <br />AS NECESSARY) <br />WATER CONTENT 250 - 300LBS. <br />AIR CONTENT (ENTRAPPED AIR ONLY) 3.0% (MAX.) <br />W/CM 0.53 (MAX.) <br />WATER REDUCER (TYPE A/F) 30Z.-10OZ./100WT +/- (MID RANGE <br />PREFERRED) <br />INITIAL SLUMP (WATER) 3" <br />FINAL SLUMP (WITH WATER REDUCER) 5.5" (MAX) <br />SHRINKAGE <0.04% @ 28 DAYS <br />2. PREPARE AND SUBMIT MIXTURES FOR EACH CLASS OF CONCRETE ON THE BASIS OF <br />LABORATORY TRIAL MIXTURES OR FIELD TEST DATA FOR REVIEW AND APPROVAL BY <br />THE STRUCTURAL ENGINEER <br />3. PROVIDE CONSTRUCTION AND CONTROL JOINTS AS INDICATED ON DRAWINGS. HORIZONTAL <br />CONSTRUCTION JOINTS ARE NOT ALLOWED UNLESS SPECIFICALLY NOTED OR APPROVED BY <br />STRUCTURAL ENGINEER. NOTIFY STRUCTURAL ENGINEER OF PROPOSED CONSTRUCTION JOINT <br />OR CONTROL JOINT LOCATIONS THAT ARE DIFFERENT OR IN ADDITION TO JOINTS INDICATED <br />ON DRAWINGS. <br />4. CHAMFER EXPOSED EDGES 3/4 INCH UNLESS OTHERWISE NOTED. <br />5. WIRE BRUSH AND CLEAN CONSTRUCTION JOINTS PRIOR TO POURING NEW CONCRETE. <br />CONCRETE CONT: <br />STRUCTURAL STEEL: <br />1 . <br />DESIGN, DETAIL AND ERECT STRUCTURAL STEEL ELEMENTS IN ACCORDANCE WITH THE <br />6. <br />REFERENCE THE APPROPRIATE DISCIPLINE DRAWINGS FOR SUBSLAB PIPING, FLOOR DRAINS <br />FOLLOWING: <br />AND SLAB AND WALL PENETRATIONS. <br />A. AISC SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS. <br />7. <br />AIR ENTRAINING ADMIXTURE MANYFACTURER SHALL PROVIDE WRITTEN CERTIFICATION <br />B. AISC MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRENGTH DESIGN. <br />THAT THE AIR -ENTRAINING ADMIXTURE IS COMPATIBLE WITH OTHER REQUIRED ADMIXTURES <br />C. AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES. <br />ALL EXTERIOR SLABS SHALL BE ENTRAINED (4%-6%). AIR-ENTRAING SHALL NOT BE USED IN <br />D. AWS STRUCTURAL WELDING CODE, D1 .1. <br />INTERIOR CONCRETE. <br />2. <br />PROVIDE STRUCTURAL STEEL OF THE FOLLOWING ASTM DESIGNATIONS UNLESS OTHERWISE <br />8. <br />COMPLY WITH RECOMMENDATIONS IN ACI 302.1 R FOR SCREEDING, RESTRAIGHTENING AND <br />NOTED: <br />FINISHING OPERATIONS FOR CONCRETE SURFACES. DO NOT WET CONCRETE. <br />A. STRUCTURAL STEEL WIDE FLANGE SHAPES: ASTM A 992 <br />B. EDGE ANGLES, BENT PLATES, HANGERS AND BRACES: ASTM A 36 <br />A. INTERIOR FLOOR SLABS: MACHINE TROWEL FINISH <br />C. STRUCTURAL PIPE: ASTM A 53, GRADE B, TYPE E OR S <br />B. EXTERIOR SLABS: LIGHT FLEXIBLE BRISTLE BROOM FINISH <br />D. HOLLOW STRUCTURAL SHAPES: ASTM A 500, GRADE C <br />E. BASE PLATES AND MISCELLANEOUS STEEL PLATES: ASTM A 36 <br />REINFORCING STEEL: <br />F. ANCHOR RODS: ASTM F 1554, GRADE 36 <br />1. <br />PROVIDE DETAILING, FABRICATION, AND INSTALLATION OF REINFORCING AND ACCESSORIES <br />3. <br />CONNECTION MATERIALS: <br />IN ACCORDANCE WITH ACI 315 AND ACI 318. <br />A. BEAM -COLUMN STIFFENER PLATES AND DOUBLER PLATES TO MATCH THE GRADE STEEL <br />OF STRUCTURAL ELEMENT <br />2. <br />PROVIDE NEW BILLET STEEL REINFORCING BARS IN ACCORDANCE WITH ASTM A 615, <br />B. HIGH STRENGTH BOLTS (SLIP CRITICAL JOINTS FOR ALL BRACES WHERE SPECIFIED): <br />GRADE 60 DEFORMED. <br />ASTM A 325 <br />C. HARDENED STEEL WASHERS: ASTM F 436 <br />3. <br />COORDINATE PLACEMENT OF CAST -IN -PLACE EMBEDS AND ANCHOR RODS. SET ANCHOR <br />RODS WITH A TEMPLATE. SECURELY ATTACH EMBED ITEMS TO FORMWORK OR REINFORCING. <br />4. <br />WELD MINIMUM SIZE AND STRENGTH: <br />A. PROVIDE MINIMUM SIZE OF FILLET WELDS AS SPECIFIED IN TABLE J2.4 OF THE AISC <br />4. <br />PROVIDE CLASS "B" REINFORCEMENT SPLICES FOR CONTINUOUS REINFORCEMENT. PROVIDE <br />MANUAL. <br />STANDARD 90-DEGREE HOOKS IN ACCORDANCE WITH ACI 318, UNLESS OTHERWISE NOTED. <br />B. PROVIDE MINIMUM EFFECTIVE THROAT THICKNESS OF PARTIAL PENETRATION GROOVE <br />WELDS AS SPECIFIED IN TABLE J2.3 OF THE AISC MANUAL. <br />5. <br />MAINTAIN THE FOLLOWING CONCRETE COVERAGE FOR REINFORCING STEEL UNLESS <br />C. DEVELOP THE FULL TENSILE STRENGTH OF THE MEMBER ELEMENT JOINED ON ALL SHOP <br />OTHERWISE NOTED: <br />AND FIELD WELDS UNLESS OTHERWISE NOTED ON THE DRAWINGS. <br />A. CONCRETE CAST AGAINST EARTH: 3 INCHES <br />D. WHERE CONNECTIONS ARE NOTED ON DRAWINGS AS MOMENT CONNECTIONS, PROVIDE <br />B. CONCRETE EXPOSED TO WEATHER <br />WELDS TO DEVELOP FULL FLEXURAL CAPACITY OF THE LESSER MEMBER. <br />NO. 6 AND LARGER: 2 INCHES <br />E. PROVIDE ELECTRODES FOR FIELD OR SHOP WELDING THAT CONFORM TO ASTM A 233 <br />NO. 5 AND SMALLER: 1 1/2 INCHES <br />(CLASS 70). <br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND: <br />F. ALL WELDS ARE CONTINUOUS FOR THE FULL LENGTH OF THE CONNECTION UNLESS <br />SLABS AND WALLS <br />OTHERWISE NOTED ON DRAWINGS. <br />1/2 <br />NO. 14 AND NO. 1 8: 1 1/2 INCHES <br />NO. 1 1 AND SMALLER: INCHES <br />5. <br />PROVIDE MINIMUM OF TWO BOLTS PER CONNECTION. PROVIDE MINIMUM BOLT DIAMETER OF <br />3/4 INCH. <br />6. <br />DO NOT WELD OR BEND REINFORCEMENT IN THE FIELD UNLESS SPECIFICALLY SHOWN OR <br />APPROVED BY STRUCTURAL ENGINEER, <br />6. <br />PROVIDE BOLTS, NUTS AND WASHERS THAT ARE HOT DIP GALVANIZED ACCORDING TO ASTM <br />A 153, CLASS C WHEN USED TO CONNECT STEEL ELEMENTS THAT ARE HOT DIP GALVANIZED <br />7. <br />WHEN SPECIFICALLY APPROVED, PROVIDE WELDED REINFORCEMENT IN ACCORDANCE WITH <br />AFTER FABRICATION. <br />ASTM A 706 GRADE 60. USE LOW HYDROGEN ELECTRODES FOR WELDING OF REINFORCEMENT <br />7 <br />PROVIDE SIMPLE SHEAR CONNECTIONS FOR STEEL CONNECTIONS NOT SPECIFIED OTHERWISE <br />IN CONFORMANCE WITH "RECOMMENDED PRACTICES FOR WELDING REINFORCING STEEL", <br />UTILIZING HIGH STRENGTH BEARING BOLTS IN SINGLE OR DOUBLE SHEAR. PROVIDE DOUBLE <br />AMERICAN WELDING SOCIETY, AWS D12.1. PROVIDE ASTM GRADE 40 REINFORCING BARS <br />ANGLE OR SINGLE PLATE SHEAR TAB BOLTED CONNECTIONS. <br />WHERE DETAILED BARS ARE TO BE WELDED TO A STEEL SECTION. <br />A. UNLESS LARGER REACTION IS SHOWN ON DRAWINGS, PROVIDE MINIMUM DESIGN FORCES <br />8. <br />WHERE REQUIRED, PROVIDE DOWELS TO MATCH SIZE AND SPACING OF MAIN REINFORCING. <br />AS FOLLOWS: <br />1. NONCOMPOSITE BEAMS: BEAM -TO -BEAM OR BEAM -TO -COLUMN CONNECTION TO <br />9. <br />PROVIDE CONTINUOUS HORIZONTAL WALL REINFORCEMENT WITH 90-DEGREE BENDS AND <br />DEVELOP THE REACTION OF CONNECTED BEAM. OBTAIN END REACTION FROM <br />EXTENSIONS AT CORNERS AND INTERSECTIONS AS SHOWN ON TYPICAL BAR PLACING DETAILS. <br />ALLOWABLE UNIFORM LOAD TABLES IN PART 2 OF THE AISC MANUAL OF STEEL <br />CONSTRUCTION. <br />10. <br />WHEN SHOWN ON DRAWINGS PROVIDE FIBRILLATED POLYPROPYLENE FIBERS ENGINEERED <br />AND DESIGNED FOR USE IN CONCRETE COMPLYING WITH ASTM C1 116, TYPE III, 1/2 TO <br />8. <br />ADD TO REACTIONS LISTED ABOVE, LOADS OR REACTIONS OF MEMBERS SUPPORTED BY <br />1 1/2 INCHES LONG. <br />BEAM WITHIN THREE FEET OF BEAM END AND VERTICAL COMPONENTS OF FORCES IN <br />BRACE MEMBERS FRAMING INTO BEAM. <br />w A A C- !1 w 1 rl %/- <br />1. REINFORCED MASONRY WORK AND MATERIALS TO BE IN ACCORDANCE WITH THE BUILDING <br />CODE FOR MASONRY STRUCTURES: TMS 402. <br />2. REINFORCED MASONRY TO CONFORM TO THE SPECIFICATIONS FOR MASONRY STRUCTURES <br />TMS 602 -2016 (WITH THE EXCEPTIONS NOTED IN JOB SPECIFICATIONS. <br />3. PROVIDE CONCRETE MASONRY UNITS (CMU) OF NORMAL WEIGHT (125 PCF MINIMUM), <br />GRADE N, TYPE I OR II, CONFORMING TO LATEST EDITION OF ASTM C 90. <br />LAY UNITS IN RUNNING BOND UNLESS OTHERWISE NOTED. <br />4. PROVIDE MASONRY ASSEMBLAGES WITH MINIMUM PRISM STRENGTH (fm) OF 2,000 PSI, <br />TESTED IN ACCORDANCE WITH ASTM C 140. <br />5. PROVIDE CONCRETE MASONRY UNITS IN ACCORDANCE ASTM C 426 LIMITS FOR DRYING <br />SHRINKAGE OF CONCRETE BLOCKS. <br />6. PROVIDE VERTICAL REINFORCEMENT IN CMU WALLS AS SHOWN IN DRAWINGS. FILL THE <br />REINFORCED CELLS SOLID WITH GROUT. MAXIMUM HEIGHT OF GROUT POURS TO BE AS <br />PER THE SPECIFICATION FOR MASONRY STRUCTURES TABLE NO. 7. UNTIL WALL IS <br />PERMANENTLY BRACED BY ROOF. <br />7. LAY HOLLOW UNITS WITH FULL MORTAR COVERAGE ON HORIZONTAL AND VERTICAL FACE <br />SHELLS. PROVIDE FULL MORTAR COVERAGE FOR WEBS WHEN ADJACENT TO GROUTED CELLS. <br />8. ALIGN VERTICAL CELLS TO BE FILLED WITH GROUT TO PROVIDE CONTINUOUS UNOBSTRUCTED <br />VERTICAL CELLS. REMOVE OVERHANGING MORTAR OR OTHER OBSTRUCTION AND DEBRIS FROM <br />THE INSIDES OF CELL WALLS. PROVIDE GROUT WITH 8 INCH SLUMP AND CONSOLIDATE BY <br />MEANS OF HAND TAMPING TO ENSURE COMPLETE FILLING OF CELLS. <br />9. INSTALL ANCHORS, ACCESSORIES, AND OTHER ITEMS TO BE BUILT IN AS WORK PROGRESSES. <br />10. PERFORM CUTTING AND FITTING OF MASONRY WITH MASONRY SAWS PROVIDING CUT <br />FINISHED UNITS. <br />11. CELLS AT OR BELOW FINISHED GRADE ARE TO BE GROUTED SOLID. <br />12. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, DO NOT SLOPE <br />DOWEL MORE THAN ONE HORIZONTAL TO SIX VERTICAL. <br />13. WALL SHALL RECEIVE TEMPORARY BRACING. TEMPORARY BRACING SHALL NOT BE REMOVED <br />UNTIL WALL IS PERMANENTLY BRACED BY ROOF. <br />14. SPECIAL INSPECTION IS REQUIRED AS FOLLOWS: <br />A. DURING PREPARATION OF REQUIRED PRISMS OR TEST SPECIMENS. <br />B. DURING THE LAYING OF MASONRY UNITS. <br />C. DURING PLACEMENT OF REINFORCING STEEL. <br />D. FOR GROUT SPACES PRIOR TO CLOSING OF CLEANOUTS AND GROUTING. <br />E. DURING ALL GROUTING OPERATIONS. <br />FORWARD INSPECTION RESULTS TO THE ENGINEER OF RECORD. <br />15. GROUT FILL CORES SHALL CONFORM TO ASTM C478 WITH A <br />MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI IN 28 DAYS. <br />16. MORTAR SHALL COMFORM TO ASTM C270 <br />A. MASONRY BELOW GRADE: TYPE M MORTAR <br />B. EXTERIOR ABOVE GRADE MASONRY: TYPE S MORTAR <br />17. GALVANIZED HORIZONTAL REINFORCEMENT SHALL HAVE W1.7 (9 GAGE) SIDE AND CROSS <br />RODS SPACED 16" ON CENTER. LAP REINFORCEMENT 7". <br />9. BRACE CONNECTIONS SHALL BE IN ACCORDANCE WITH THE DETAILS SHOWN ON THE <br />DRAWINGS. ANGLE SIZES, PLATE SIZES, AND SIZE AND LENGTHS OF WELDS SHALL BE <br />DESIGNED IN ACCORDANCE WITH THE FOLLOWING: <br />A. DESIGN CONNECTIONS OF DIAGONAL MEMBERS TO DEVELOP THE LOADS SHOWN ON <br />THE BRACE DETAILS. <br />B. WHERE FORCES ARE NOT INDICATED ON THE DETAILS, DESIGN CONNECTIONS OF <br />DIAGONAL MEMBERS TO DEVELOP THE FULL TENSILE CAPACITY OF THE DIAGONAL <br />MEMBER. <br />C. SIZE GUSSET PLATES AND ALL WELDS TO RESIST THE FORCE OF THE DIAGONAL <br />MEMBERS. PLATES AND WELDS SHALL BE SIZED FOR TENSIONS, SHEARS, AND <br />MOMENTS CAUSED BY CONCENTRIC AND ECCENTRIC FORCES. <br />D. ALL BRACE CONNECTIONS SHALL USE WELDS OR FULLY TENSIONED A325 CLASS <br />A SLIP CRITICAL BOLTS. <br />10. STEEL FABRICATION: <br />A. FABRICATE AND ASSEMBLE STRUCTURAL MEMBERS/ASSEMBLIES IN SHOP TO <br />GREATEST EXTENT POSSIBLE. <br />B. CAMBER OF STRUCTURAL STEEL MEMBERS IS INDICATED ON THE DRAWINGS. <br />WHERE POSSIBLE, CAMBER OF BEAMS TO BE APPLIED BY COLD BEND PROCESS. <br />CAMBER INDICATED ON DRAWINGS IS INTENDED TO BE FINAL CAMBER AT TIME <br />OF ERECTION, AND WITHIN A TOLERANCE OF MINUS ZERO TO PLUS ONE -EIGHTH <br />INCH FOR EACH TEN FEET OF MEMBER LENGTH. <br />C. SPLICING OF STRUCTURAL STEEL MEMBERS IS PROHIBITED WITHOUT PRIOR <br />APPROVAL BY THE A/E. <br />D. BE RESPONSIBLE FOR ALL ERRORS OF DETAILING ON THE SHOP DRAWINGS, <br />ERRORS IN FABRICATION, AND THE CORRECT FITTING OF STRUCTURAL STEEL <br />MEMBERS. <br />E. CONFORM TO THE AISC CODE OF STANDARD PRACTICE, FOR ERECTION TOLERANCES. <br />FIELD MODIFICATION TO STRUCTURAL STEEL IS PROHIBITED WITHOUT PRIOR <br />APPROVAL BY THE A/E. <br />F. CLEAN STEEL OF RUST, LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS <br />WHERE REQUIRED FOR FABRICATION, FITTING UP, OR WELDING. <br />G. DO NOT CUT STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER TRADES <br />WITHOUT PRIOR REVIEW AND APPROVAL OF THE A/E. <br />11. HOT DIP GALVANIZE AFTER FABRICATION ALL STRUCTURAL STEEL AND THEIR CONNECTIONS <br />PERMANENTLY EXPOSED TO THE OUTSIDE. ITEMS INCLUDED BUT NOT LIMITED TO: <br />A. SHELF ANGLES. <br />B. PARAPET WALL SUPPORTING MEMBERS <br />C. EMBEDDED PLATES IN CONCRETE <br />D. BUILDING CLADDING SUPPORT STEEL <br />E. EXAMINE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR OTHER ITEMS THAT <br />REQUIRE HOT DIPPED GALVANIZATION. <br />12. PROVIDE GROUT FOR BASE PLATES THAT IS NON -SHRINK, NON-METALLIC GROUT WITH <br />MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 6000 PSI. COMPLETE GROUT WORK PRIOR <br />TO PLACING ROOF CONCRETE OF A SINGLE STORY BUILDING OR PRIOR TO PLACING <br />SECOND FLOOR CONCRETE OF A MULTIPLE STORY BUILDING. <br />13. SUBMIT CALCULATIONS FOR CONNECTION DESIGNS NOT DETAILED ON DRAWINGS. DESIGN <br />CONNECTIONS UNDER SUPERVISION OF REGISTERED PROFESSIONAL ENGINEER, REGISTERED <br />IN THE STATE WHERE PROJECT IS BEING CONSTRUCTED, EMPLOYED BY THE STEEL <br />FABRICATOR. DESIGN CALCULATIONS TO BE SEALED BY FABRICATOR'S REGISTERED <br />PROFESSIONAL ENGINEER. SHOP DRAWINGS SUBMITTED WITHOUT COMPLETE DESIGN <br />CALCULATIONS WILL NOT BE REVIEWED. WHERE PREDESIGNED CONNECTIONS ARE TAKEN <br />DIRECTLY FROM TABLES IN AISC MANUAL, CALCULATIONS NEED NOT BE SUBMITTED PROVIDED <br />JOB DESIGN CONDITIONS PRECISELY MATCH THOSE ASSUMED IN THE AISC MANUAL. <br />STRUCTURAL STEEL CONT: <br />14. PROVIDE WASHERS FOR ALL CONNECTIONS WITH STANDARD, OVERSIZE AND SHORT <br />SLOTTED HOLES. FOR LONG -SLOTTED HOLES PROVIDE WASHERS OR A CONTINUOUS <br />BAR OF SUFFICIENT SIZE TO COMPLETELY COVER THE SLOT. PLATE WASHERS OR BARS <br />TO BE MINIMUM OF 5/16 INCH THICK FOR LONG -SLOTTED HOLES. <br />15. WIDE FLANGE BEAM CONNECTIONS TO TUBE COLUMNS SHALL BE MADE WITH BOLTED <br />SHEAR TAB PLATE TYPE CONNECTIONS UNLESS OTHERWISE NOTED ON PLAN. ONE-SIDED <br />CONNECTIONS SHALL BE DESIGNED AS ECCENTRIC CONNECTIONS. <br />16. FURNISH STEEL SHOP DRAWINGS FOR ARCHITECT'S AND STRUCTURAL ENGINEER'S REVIEW <br />PRIOR TO FABRICATION. INCLUDE WELDING PROCEDURES, TESTING PROGRAMS FOR <br />WELDING AND HIGH STRENGTH BOLTING, COATING MATERIAL AND ERECTION SEQUENCE <br />ON SHOP DRAWINGS. <br />17. MILL STEEL COLUMN ENDS TO FIT FLUSH WITH BASE PLATE, CAP PLATE AND END PLATES. <br />FIELD ASSEMBLY OF THESE STEEL ELEMENTS TO THE COLUMNS IS PROHIBITED. <br />18. HEADED STUDS (SHEAR AND ANCHOR) AND DEFORMED ANCHORS: <br />A. PROVIDE HEADED STUDS (SHEAR AND ANCHOR) MADE OF MATERIAL CONFORMING TO <br />ASTM A 108. <br />B. PROVIDE DEFORMED ANCHORS MADE OF MATERIAL CONFORMING TO ASTM A 496. <br />C. WELD STUDS ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. MANUAL ARC <br />(STICK) WELDING OF HEADED STUDS AND/OR DEFORMED ANCHORS IS NOT ALLOWED. <br />19. PRIOR TO DECK PLACEMENT, VERIFY THAT STEEL BEAMS BEARING ON MASONRY HAV <br />8 INCH MINIMUM BEARING AND ARE ANCHORED AS SHOWN ON DRAWINGS. <br />20. PROVIDE TEMPORARY SHORING OR BRACING DURING CONSTRUCTION PHASE, PRIOR TO <br />COMPLETING CONNECTIONS AND POURING OF FLOOR SLAB. TEMPORARY CONSTRUCTION <br />BRACING OF THE STRUCTURAL STEEL FRAME IS THE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL REMAIN IN PLACE UNTIL AFTER THE PERMANENT BRACING <br />SYSTEM HAS BEEN COMPLETED. <br />21. CLEAN STEEL TO BE PAINTED IN ACCORDANCE WITH STEEL STRUCTURES PAINTING COUNCIL <br />POWER TOOL CLEANED SSPC-SP3. <br />22. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED WHITE OR LIGHT GREY TO PROVIDE DRY <br />FILM THICKNESS NOT LESS THAN 1.0 MIL: ASPHALTIC PAINTS ARE NOT ACCEPTABLE. <br />LIGHT GAGE STEEL: <br />1. PROVIDE ALL STUDS AND/OR JOISTS AND ACCESSORIES OF THE TYPE, SIZE, GAGE AND <br />SPACING SHOWN ON THE DRAWINGS. <br />2. DESIGN ALL STRUCTURAL MEMBERS IN ACCORDANCE WITH AMERICAN IRON AND STEEL <br />INSTITUTE (AISI) "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED <br />STEEL MEMBERS" <br />3. FORM ALL FRAMING MEMBERS FROM CORROSION RESISTANT STEEL, CORRESPONDING TO <br />THE REQUIREMENTS OF ASTM A653 AND THE FOLLOWING STRENGTH REQUIREMENTS: <br />FRAMING MEMBER GAGE MINIMUM YIELD <br />STUDS, JOISTS 20,18 33 KSI <br />STUDS, JOISTS 10,12,14,16 50 KSI <br />RUNNERS, SOLID BLOCKING 20 33 KSI <br />4. PLACE ALL COLD -FORMED STEEL STUD WALL BRIDGING HORIZONTALLY WITH A MAXIMUM <br />VERTICAL SPACING OF FOUR FEET UNLESS OTHERWISE NOTED. AS AN OPTION, CONTINUOUS <br />COLD -FORMED CHANNELS MAY BE POSITIONED THROUGH THE STUD PUNCH OUTS AS <br />BRIDGING PROVIDED THE CHANNEL IS PROPERLY FASTENED TO EACH STUD. <br />5. INSTALL AXIALLY LOADED STUDS IN A MANNER WHICH WILL ASSURE THAT THEIR ENDS ARE <br />POSITIONED AGAINST THE INSIDE OF RUNNER WEB PRIOR TO FASTENING. <br />6. FASTEN COMPONENTS WITH SELF -DRILLING SCREWS OR WELDING. PROVIDE SCREWS OF <br />SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION. WIRE TYING OF <br />COMPONENTS IS NOT PERMITTED. TOUCH UP ALL WELDS WITH A ZINC -RICH PAINT. <br />LIGHT GAGE STEEL CONT: <br />7. WELDING OF COLD -FORMED STUDS MAY BE PERFORMED USING A MINIMUM <br />ONE -EIGHTH INCH AWS TYPE 6013 WELDING ROD. <br />8. SECURELY ANCHOR RUNNERS TO THE SUPPORTING STRUCTURE. PROVIDE COMPLETE, <br />UNIFORM, AND LEVEL BEARING SUPPORT FOR THE BOTTOM RUNNER. <br />9. SECURELY ANCHOR ABUTTING LENGTHS OF RUNNER TO A COMMON STRUCTURAL <br />ELEMENT BUTT -WELDED OR SPLICED. <br />10. PLUMB, ALIGN, AND SECURELY ATTACH STUDS TO THE FLANGES OF BOTH UPPER AND <br />LOWER RUNNERS. SPLICES IN STUDS ARE NOT PERMITTED. <br />11. PROVIDE HEADERS AND SUPPORTING STUDS FOR FRAMING OF WALL OPENINGS. <br />12. STABILITY BRIDGING SHALL BE INSTALLED AT A MAXIMUM 4'-0" O.C. FOR SUSPENDED <br />SOFFITS UNLESS OTHERWISE NOTED. <br />13. DESIGN OF METAL STUD FRAMING SHOWN IS BASED ON CEE TYPE (1 5/8" FLANGE) <br />STUDS BY DALE INDUSTRIES. <br />14. SHOP DRAWINGS AND CALCULATIONS FOR COLD FORMED METAL FRAMING TO BE <br />SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE <br />WHERE THE PROJECT IS LOCATED. <br />PRE-ENGINEERED METAL BUILDING (PEMB) <br />A. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL DESIGN AND <br />FURNISH ALL FRAMING TYPICAL UNLESS SPECIFICALY STATED ON THE <br />STRUCTURAL DRAWINGS OTHERWISE. <br />B. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL PROVIDE SHOP <br />DRAWINGS IN A TIMELY MANNER PRIOR TO FABRICATION TO VERIFY LOADS <br />USED FOR FOUNDATION DESIGN. <br />C. FOUNDATION DESIGN AS SHOWN ON STRUCTURAL DRAWINGS IS PRELIMINARY <br />ONLY. ITEM B. SHOULD BE SUBMITTED FOR FINAL DESIGN. <br />D. PRE-ENGINEERED METAL BUILDING MANUFACTURER SHALL DESIGN & SUPPLY <br />ENGINEERING FOR ROOF OPENINGS, ROOF TOP UNITS, AND ANY HUNG LOADS <br />WITH OTHER TRADES. <br />THE SCOPE OF THE PRE -MANUFACTURED METAL BUILDING STRUCTURE <br />SHALL INCLUDE THE DESIGN, ENGINEERING, FABRICATION, DELIVERY, AND <br />ERECTION OF THE COMPLETE STRUCTURAL STEEL FRAMING AND EXTERIOR <br />SKIN PACKAGE. THE METAL BUILDING MANUFACTURER SHALL BE CERTIFIED <br />BY AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) METAL BUILDING <br />CERTIFICATION PROGRAM <br />REQUIRED NATIONAL ACCOUNT VENDORS <br />COMPANY CONTACTS PHONE # REQUIRED ITEMS <br />RAINBIRD IRRIGATION LOCAL RAIN BIRD DISTRIBUTER WWW.RAINBIRD.COM IRRIGATION SYSTEMS <br />EUCLID CHEMICAL <br />COMPANY <br />RETRO-PLATE SYSTEMS <br />PROTOTYPE MANAGEMENT TEAM <br />COMPANY I CONTACTS PHONE # <br />MJM ARCHITECTS I GARY CONWAY 615-244-8170 1 www.mimarch.com <br />ENTECH <br />CONSULTANT: <br />SEAL: GARY MAEDA, PE 68724 <br />� ; •4� P1 �') fP <br />N®.68724 <br />STATE .f, <br />THIS DRAWING SHALL NOT BE USED FOR <br />CONSTRUCTION PURPOSES'UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNER'S AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />03/29/2021 <br />PEMB COORDINATION <br />05/20/2021 <br />CIVIL SUBMISSION <br />05/20/2021 <br />DUKE COORDINATION <br />06/07/2021 <br />PEMB COORDINATION 02 <br />08/09/2021 <br />CIVIL RESUBMISSION 1 <br />08/25/2021 <br />OWNER REVIEW <br />1 1 /08/2021 <br />REVISED ELEVATIONS <br />1 1 /29/2021 <br />PERMIT SUBMITTAL <br />Project Manager <br />Drawn <br />L. LONG <br />D. GRIFFIN <br />Project Leader <br />Checked <br />L. LONG <br />Date <br />Dept Mgr Approval <br />02/23/2021 <br />G MAEDA <br />Client <br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC <br />P.O. Box 1615, <br />Thomasville, GA 31 799 <br />Office: (229) 226-1 1 77 <br />Contact: Daniel Tubb <br />Project <br />DOLLAR GENERAL <br />Corner of Gall Boulevard and C <br />Avenue, <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 23227 <br />Drawing Title <br />STRUCTURAL <br />GENERAL NOTES <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />JCDT.20.0451 <br />S1 <br />