MANUAL PULL STA' <br />CEILING MOUNTED <br />SMOKE DETECTOR <br />DUCT TYPE <br />SMOKE DETECTOR <br />CEILING MOUNTED <br />COMBINATION <br />HORN/STROBE <br />WALL MOUNTED <br />COMBINATION <br />HORN/STROBE <br />TAMPER SWITCH <br />F <br />FLOW SWITCH <br />SD TS F <br />CEILING TYPE STROBE <br />-CEILING MOUNTED <br />SMOKE DETECTOR <br />LOCATED ABOVE <br />THE FACP <br />E FOR NOTE: <br />ONITORING FIRE ALARM SYSTEM SHALL COMPLY <br />WITH FLORIDA BUILDING CODE (201 7) <br />k-8 AND NFPA 72, 2013 EDITION <br />BLE FIRE ALARM CONTROL PANEL <br />WITH BUILT-IN INTERNAL SURGE PROTECTION <br />DEVICES TO PROTECT BOTH POWER AND <br />DATA LINES TO ISOLATE THE FIRE ALARM <br />CONTROL PANEL. <br />FIRE ALARM RISER DIAGRAM <br />Scale: NTS <br />SYMBOL <br />FIRE ALARM SYSTEM SYMBOL SCHEDULE <br />DESCRIPTION <br />FWALL MOUNTED FIRE ALARM PULL STATION <br />A CEILING MOUNTED FIRE ALARM STROBE <br />A\ <br />CEILING MOUNTED COMBINATION FIRE ALARM HORN AND STROBE <br />C <br />F <br />WALL MOUNTED COMBINATION FIRE ALARM HORN AND STROBE <br />W <br /><FF O/WP <br />WALL MOUNTED AND WEATHER-PROOF COMBINATION FIRE ALARM <br />W <br />HORN AND STROBE <br />s <br />DUCT MOUNTED SMOKE DETECTOR (MOUNT IN RETURN AIR DUCT) <br />OCEILING <br />MOUNTED SMOKE DETECTOR <br />TS WP <br />WEATHER-PROOF FIRE RISER TAMPER SWITCH <br />WF WP <br />WEATHER-PROOF FIRE RISER WATER FLOW SWITCH <br />NOTES: <br />1. FIRE ALARM SYSTEM SHALL PROVIDE A GENERAL EVACUTATION SIGNAL FOR THE <br />ENTIRE BUILDING. <br />2. PROVIDE WIRING PER NFPA 72. <br />3. ABOVE GROUND AND UNDERGROUND WIRING SHALL COMPLY WITH CHAPTER 12 <br />IN NFPA 72. <br />4. TRANSIENT PROTECTION SHALL COMPLY WITH CHAPTER 12 IN NFPA 72. <br />5. ALL DUCT DETECTORS SHALL BE WIRED TO ACTIVATE ALARM SYSTEM AND SHUT <br />DOWN FAN. <br />6. FIRE ALARM CONTRACTOR TO VERIFY THAT THE CANDELA INTENSITY OF THE STROBE <br />LIGHTS SHOWN COMPLYS WITH TABLES 7.5.4.3.1(a) AND 7.5.4.3.1 (b) IN NFPA 72. <br />AUDIO LEVEL SHALL COMPLY WITH NOTIFICATION IN CHAPTER 18, NFPA 72. ALL <br />AUDIO AND VISUAL RATINGS SHALL MEET OR EXCEED NFPA REQUIREMENTS. <br />7. PROVIDE REMOTE POWER SUPPLIES AS REQUIRED FOR NOTIFICATION APPLIANCE <br />CIRCUITS, NOT TO EXCEED 80% OF CAPACITY. <br />8. PROVIDE SMOKE DETECTOR ABOVE EACH REMOTE POWER SUPPLY PANEL. <br />9. IF REQUIRED, SMOKE DETECTOR LAYOUT SHALL COMPLY WITH SECTIONS 17.5 AND <br />17.7 IN NFPA 72. ADDITIONAL SMOKE DETECTORS SHALL BE PROVIDED TO REMOVE <br />SMOKE STRATIFICATION. <br />10. PROVIDE BATTERY, CURRENT LOAD AND VOLTAGE DROP CALCULATIONS PER NFPA. <br />11. SEAL AROUND ALL PIPES & CONDUITS IN MASONRY AND DRYWALL WALLS. <br />12. EXTERIOR DEVICES SHALL BE SUBJECT TO ENVIROMENTAL FACTORS INCLUDING BUT <br />NOT LIMITED TO: HUMIDITY, TEMPERATURE AND CORROSIVE ATMOSPHERES <br />(INCLUDING COASTAL SALT AIR). <br />13. ALL FIRE ALARM WIRING SHALL BE MINIMUM # 14 AWG AND IN CONDUIT MIN 3/4" IN <br />EXPOSED CEILING AREAS, PLENUM RATED CABLE IS ACCEPTABLE ABOVE LAY -IN CEILINGS <br />IN J-HOOKS. <br />14. FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHARGES INVOLVED IN <br />OBTAINING APPROVAL AND CERTIFICATION FROM STATE ELECTRICAL INSPECTOR FOR A <br />COMPLETE SYSTEM. CERTIFIED CONTRACTOR TO PAY ALL FEES REQUIRED. <br />1 5. THE RISER DIAGRAM IS FOR REFERENCE PURPOSES. EXACT QUANTITIES OF DEVICES AND <br />LOCATIONS SHALL COMPLY WITH NFPA GUIDELINES AND MEET APPROVAL OF THE <br />STATE ELECTRICAL INSPECTOR. FIRE ALARM CONTRACTOR SHALL HAVE SHOP <br />DRAWINGS APPROVED BY THE STATE ELECTRICAL INSPECTOR PRIOR TO <br />COMMENCEMENT OF WORK. <br />16. SYSTEM TESTING SHALL COMPLY WITH NFPA 72. <br />17. SYSTEM OPERATION AND MAINTENANCE PROCEDURES, MANUALS, SYSTEM <br />DOCUMENTATION AND INSTRUCTION OF OWNER'S OPERATING PERSONAL SHALL BE <br />PROVIDED PER NFPA 72. <br />18. CONTRACTOR SHALL COORDINATE LOCATION OF FIRE ALARM DEVICES WITH THE <br />LATEST DOLLAR GENERAL FIXTURE PLAN. <br />19. THE NEW FIRE ALARM SYSTEM SHALL BE INSPECTED AND TESTED IN ACCORDANCE WITH <br />THEREQUIREMENTS OF NFPA 72, CHAPTER 14, "INSPECTION TESTING AND <br />MAINTENANCE." [72:14.4.1 .1 ]. VERIFICATION OF COMPLIANT INSTALLATIONSHALL BE <br />PERFORMED ACCORDING TO TESTING REQUIREMENTS AND PROCEDURES SPECIFIED IN <br />72:14.4.1 "INITIAL ACCEPTANCE TESTING." A RECORD OF ALL INSPECTIONS, TESTING <br />AND MAINTENANCESHALL BE PROVIDED THAT INCLUDES THE FOLLOWING <br />INFORMATION (72:14.6.2.4 (1) THROUGH (19)) REGARDING TESTSAND ALL APPLICABLE <br />INFORMATION REQUESTED IN 72:F.14.6.2.4. [72:14.6.2.4*]. ALL INTEGRATED SYSTEMS <br />SHALL BE TESTED, [4:1.1 .1 *]. <br />20. AFTER SUCCESSFUL COMPLETION OF ACCEPTANCE TESTS APPROVED BY THE AHJ, THE <br />REQUIREMENTS OF 72:14.6.1.1 THROUGH 72:14.6.1.3 SHALL COMPLY. [72:14.6.1 J. <br />A) A SET OF REPRODUCIBLE AS -BUILT INSTALLATION DRAWINGS, OPERATION AND <br />MAINTENANCE MANUALS AND A WRITTEN SEQUENCE OF OPERATION SHALL BE <br />PROVIDED TO THE BUILDING OWNER OR THEIR DESIGNATED REPRESENTATIVE. <br />[72:14.6.1.1 ]. <br />B) FOR SOFTWARE BASED SYSTEMS, A COPY OF THE SITE -SPECIFIC SOFTWARE SHALL <br />BE PROVIDED TO THESYSTEM OWNER OR OWNER'S DESIGNATED REPRESENTATIVE. <br />[72:14.6.1.2.11. <br />C) THE COPY OF THE SITE -SPECIFIC SOFTWARE SHALL BE STORED ON SITE IN A <br />NON-VOLATILE, NON-ERASEABLE AND NON-REWRITABLE MEMORY. [72:14.6.1 .2.2]. <br />D) THE SYSTEM OWNER SHALL BE RESPONSIBLE FOR MAINTAINING THESE RECORDS <br />FOR THE LIFE OF THE SYSTEM FOR EXAMINATION BY ANY AHJ. PAPER OR <br />ELECTRONIC MEDIA SHALL BE PERMITTED. [72:14.6.1 .31. <br />21. THE FIRE ALARM CONTRACTOR SHALL VERIFY THAT THE RADIO STRENGTH <br />DETERMINED BY THE FIRE MARSHAL IS ADEQUATE FOR FIRE GROUND / DEPARTMENT <br />COMMUNICATIONS. If THE SIGNAL STRENGTH IS NOT ACCEPTABLE AN ENHANCEMENT <br />SYSTEM SHALL BE INSTALLED. <br />2. FIKt ALARM Ut5)KjNtK QUALIFIC,A I IUN5: NICt I LtVtL III UK IV (3 UK 4) CLK I IFILU FIKL <br />ALARM TECHNICIAN OR REGISTERED FIRE PROTECTION ENGINEER, EMPLOYED BY THE <br />FIRE ALARM CONTROL PANELMANUFACTURER, CONTRACTOR, OR INSTALLER, WITH <br />EXPERIENCE DESIGNING FIRE ALARM SYSTMS IN THE JURISDICTIONAL AREA OF THE <br />AUTHORITIES HAVING JURISDICTION. <br />FIRE ALARM SEQUENCE OF OPERATION <br />THE ACTIVATION OF ANY FIRE ALARM AUTOMATIC DETECTOR CIRCUIT SHALL <br />AUTOMATICALLY PERFORM THE FOLLOWING FUNCTIONS: <br />1. SEND A SIGNAL TO THE FIRE ALARM COMPANY WHICH CALLS THE FIRE DEPARTMENT <br />AND THE CUSTOMER PROVIDED CALL LIST. <br />2. LIGHT THE FIRE ALARM CONTROL PANEL'S RED LED AND AUDIBLE SONALERT AND <br />DISPLAY A DESCRIPTION OF THE DEVICE CAUSING THE ALARM. <br />3. ALL AUDIBLE ALARM SIGNALS SHALL SOUND UNTIL SILENCED BY THE ALARM SILENCE <br />BUTTON. IF ALARM SIGNALS ARE SILENCED FOR ANY REASON THEY SHALL <br />AUTOMATICALLY RESOUND IF ANOTHER ZONE ACTIVATES. <br />4. ALL SIGNALS SHALL FLASH UNTIL STOPPED BY THE SILENCE BUTTON. IF VISUAL <br />SIGNALS ARE STOPPED FOR ANY REASON THEY SHALL AUTOMATICALLY RESOUND IF <br />ANOTHER ZONE ACTIVATES. <br />5. POWER FAILURE, OPEN CIRCUIT OR OTHER ABNORMAL CONDITIONS IN THE FIRE <br />ALARM CIRCUITS SHALL CAUSE THE TROUBLE SIGNAL TO SOUND AND TH AMBER ZONE <br />TROUBLE LIGHT TO GLOW ON THE FIRE ALARM CONTROL PANEL, INDICATING WHICH <br />CIRCUIT IS IN A DIS ARRANGED CONDITION. THE SILENCE BUTTON MAY BE SELECTED <br />TO SILENCE THE AUDIBLE SIGNAL BUT THE TROUBLE LAMP SHALL NOT BE <br />EXTINGUISHED UNTIL THE ABNORMAL CONDITION IS RECTIFIED. <br />6. IN THE EVENT OF A COMMERCIAL POWER INTERRUPTION THE SYSTEM SHALL <br />AUTOMATICALLY TRANSFER TO AN EMERBENCY STANDBY BATTERY SOURCE. <br />7. DUCT SMOKE DETECTORS SHALL AUTOMATICALLY STOP THEIR RESPECTIVE FANS(S) ON <br />DETECTING THE PRESENCE OF SMOKE. <br />8. SPRINKLER SYSTEM FLOW SWITCH AND TAMPER SWITCHES SHALL INDICATE AS A <br />COMMON SUPERVISORY CONDITION AND SHALL TRANSMIT A SUPERVISORY SIGNAL TO <br />THE FIRE ALARM PANEL. <br />FIRE ALARM INSTALLATION REQUIREMENTS: <br />POWER LIMITED FIRE ALARM CIRCUITS SHALL BE INSTALLED IN ACCORDANCE WITH <br />NEC ARTICLE 760. CONDUCTORS SHALL BE EITHER SOLID OR STRANDED COPPER <br />MINIMUM OF #14 AWG. <br />FIRE ALARM CIRCUITS INSTALLED IN CORROSIVE, DAMP OR WET LOCATIONS MUST BE <br />IDENTIFIED FOR USE IN THE OPERATING ENVIRONMENT, MUST BE OF MATERIALS <br />SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE INSTALLED, AND MUST BE OF <br />A TYPE SUITABLE FOR THE APPLICATION. <br />COVERS OF BOXES AND CABINETS SHALL BE PAINTED RED AND PERMANENTLY <br />IDENTIFIED AS TO THEIR USE. <br />EXPOSED CABLES SHALL BE SUPPORTED BY THE STRUCTURAL COMPONENTS OF THE <br />BUILDING SO THAT THE CABLE WILL NOT BE DAMAGED BY NORMAL BUILDING USE. <br />EXPOSED CABLES MUST BE SECURED BY STRAPS, STAPLES, CABLE TIES, HANGERS, OR <br />SIMILAR FITTINGS DESIGNED AND INSTALLED TO NOT DAMAGE THE CABLE. POWER <br />LIMITED FIRE ALARM CABLES SHALL NOT BE STRAPPED TO THE EXTERIOR OF ANY <br />RACEWAY AS A MEANS OF SUPPORT. <br />FIRE ALARM CIRCUITS MUST BE IDENTIFIED AT ALL TERMINAL AND JUNCTION BOX <br />LOCATIONS. FIRE ALARM CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED <br />FITTINGS, BOXES OR ENCLOSURES FIRE ALARM DEVICES OR UTILIZATION EQUIPMENT. <br />FIRE ALARM CIRCUITS LOCATED IN NON -ACCEPTABLE LOCATIONS OR BELOW 8 FEET <br />MUST BE INSTALLED IN METALLIC CONDUIT. THIS INCLUDES AREAS BEHIND HARD <br />CEILINGS AND DRYWALL. <br />All DIRECT BURIAL FIRE ALARM CABLE NOT PROTECTED IN CONDUIT MUST BE <br />INSTALLED AT A MINIMUM DEPTH OF 24" BELOW GRADE WITH EITHER SCHEDULE 80 <br />NORTH PVC OR RIGID CONDUIT UP TO THE DEVICE. DIRECT BURIAL CABLE INSTALLED IN <br />i FIRE ALARM PLAN PLASTICCONDUIT <br />80 UIT MUST BE INSTALLED AT A MINIMUM OF 1 8" BELOW GRADE IN <br />SCHEDULE <br />1 Scale. 1/8 - 1-0 <br />CONSULTANT: <br />SEAL: SEAN PATRICK PIC-KELL, PE 83946 <br />` G. s F / <br />0 ; No.83948 <br />STATE OF <br />F A <br />THIS DRAWING SHALL NOT BE USED FOR <br />CONSTRUCTION PURPOSES 'UNTIL THE SEAL AND <br />SIGNATURE OF THE RESPONSIBLE REGISTRANT <br />APPEARS ON THE DRAWING, AND PROPER PERMIT <br />FORMS AND RELATED FEES ARE TRANSMITTED BY <br />THE OWNER, OWNER'S AGENT OR CONTRACTOR <br />TO THE AUTHORITY HAVING JURISDICTION. <br />DATE <br />ISSUED FOR <br />REV <br />03/29/2021 <br />PEMB COORDINATION <br />05/20/2021 <br />CIVIL SUBMISSION <br />05/20/2021 <br />DUKE COORDINATION <br />06/07/2021 <br />PEMB COORDINATION 02 <br />08/09/2021 <br />CIVIL RESUBMISSION 1 <br />08/25/2021 <br />OWNER REVIEW <br />1 1 /08/2021 <br />REVISED ELEVATIONS <br />1 1 /29/2021 <br />PERMIT SUBMITTAL <br />Project Manager <br />Drawn <br />L. LONG <br />N. NGUYEN <br />Project Leader <br />Checked <br />L. LONG <br />S. PIC-KELL <br />Date <br />Dept Mgr Approval <br />02/23/2021 <br />M. GOOD <br />Client <br />PALMETTO ZEPHYRHILLS - GALL BLVD., LLC <br />P.O. Box 1615, <br />Thomasville, GA 31 799 <br />Office: (229) 226-1 177 <br />Contact: Daniel Tubb <br />Project <br />DOLLAR GENERAL <br />Corner of Gall Boulevard and C <br />Avenue, <br />Zephyrhills, FL 33542 <br />(City of Zephyrhills) <br />Store #: 23227 <br />Drawing Title <br />FIRE ALARM PLAN <br />DO NOT SCALE DRAWING <br />Project No. <br />Drawing No. <br />JCDT.20.0451 <br />E6 <br />