I ELECTRICAL POWER NOTES I <br />A. ALL ELECTRICAL OUTLETS SHOWN ON THIS PLAN ARE FOR FIXTURES AND EQUIPMENT SPECIFIED AS <br />FURNISHED BY THE KITCHEN EQUIPMENT CONTRACTOR, UNLESS OTHERWISE NOTED. FOR ANY <br />ADDITIONAL CONVENIENCE OUTLETS, COORDINATE LOCATION(S) WITH OWNER'S REP. <br />B. ALL DIMENSIONS, WHERE GIVEN, ARE FROM COLUMN CENTERLINE AND/OR ROUGH WALLS. ELEVATIONS <br />GIVEN ARE FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. ALL OUTLETS ARE TO BE SET <br />VERTICALLY UNLESS OTHERWISE REQUIRED BY A.H.J.. ALL 120V OUTLETS NOT DESIGNATED WITH <br />SPECIFIC LOADS, TO BE RATED AT 15 AMPS MINIMUM. <br />C. ALL ROUGH —INS SHOWN ARE TO BE RUN INSIDE WALLS, (EXCEPT STUB —UPS). LOCATIONS INDICATED <br />POINT OF EXIT FROM WALLS, CEILING OR FLOOR. REFER TO KITCHEN EQUIP. DRAWINGS FOR <br />REQUIREMENTS AND MOUNTING HEIGHTS USE FORE PUTTY TO MAINTAIN FIRE RATINGS. <br />D. ELECTRICIAN TO BRANCH TO CONNECTION WHERE REQUIRED AND TO CONNECT ALL ELECTRICAL <br />EQUIPMENT AND FIXTURES AND INSTALL ANY INTERNAL WIRING REQUIRED IN THE FIXTURES <br />INCLUDING INTERWIRING TO APPLIANCES, APPLIANCE POWER SUPPLIES, ETC. AS REQUIRED BY THE <br />SPECIFICATIONS AND/OR EQUIPMENT DRAWINGS. <br />E. ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL REQUIREMENTS OF ALL OWNER FURNISHED <br />EQUIPMENT AND MAKE ADJUSTMENTS AS REQUIRED BEFORE ELECTRICAL ROUGH —INS. <br />F. ALL KITCHEN AND FOOD PREP. ELECTRICAL OUTLET COVER PLATES ARE TO BE STAINLESS STEEL. <br />THOSE REQUIRED IN BUILDING STRUCTURE ARE TO BE FURNISHED BY THE ELECTRICIAN, WITH <br />RECEPTACLE. ALL MAIN BREAKER PANELS AND DISCONNECT SWITCHES REQUIRED TO BE FURNISHED <br />AND INSTALLED BY THE ELECTRICAL CONTRACTOR AT TIME OF INSTALLATION. <br />G. UNLESS OTHERWISE INDICATED THE ELECTRICAL LOADS SPECIFIED ARE THE CONNECTED LOADS, FUSE <br />OR CIRCUIT BREAKER SIZE TO BE DETERMINED ACCORDINGLY, BASED UPON APPLICABLE CODE <br />REQUIREMENTS. OMISSIONS OR ERRORS IN THE SCHEDULE DO NOT RELIEVE ELECTRICAL CONTRACTOR <br />FROM COMPLETE AND CORRECT FINAL CONNECTION RESPONSIBILITY. REVIEW OF EQUIPMENT <br />BROCHURE BOOK AND SHOP DRAWINGS WILL ASSURE CORRECTNESS OF THIS WORK. <br />H. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL SWITCHES, STARTERS, DISCONNECTS, ETC. <br />FOR ALL EQUIPMENT UNLESS NOTED OTHERWISE. ALL DISCONNECTS OR LOCK —OUT DEVICES, <br />STARTERS, ETC. TO MEET N.E.C. AND O.S.H.A. STANDARDS. <br />I. RECEPTACLES SHALL BE GROUNDED PER N.E.C. AND O.S.H.A. AND TO HAVE NO GROUND FAULT <br />PROTECTION, EXCEPT WHEN OUTLET OCCURS WITHIN 6'-0" OF A SINK. RECEPTACLES WITHIN <br />KITCHEN, AND PREP. AREAS SHALL HAVE GROUND FAULT PROTECTION (GFCI). <br />J. ELECTRICAL CONTRACTOR TO PROVIDE CONTROL WIRING AND ELECTRICAL SERVICE FOR REMOTE <br />REFRIGERATION SYSTEMS FOR WALK—IN BOXES, ALSO COORDINATE LOCATION FOR SERVICE WITH THE <br />ELECTRICAL ENGINEER. INSPECT EXISTING SYSTEM COMPONENTS AND REPAIR/REPLACE AS NEEEDED, <br />AS APPLICABLE. <br />K. ELECTRICAL CONTRACTOR TO PROVIDE WRAP AROUND HEATER CABLE (HEAT TRACE) ON ALL <br />EVAPORATOR DRAIN LINES IN WALK—IN FREEZERS. <br />L. ELECTRICAL CONTRACTOR TO INSTALL ALL LIGHTS IN WALK—IN COOLER/FREEZER AS REQUIRED, THRU <br />DOOR SWITCH. <br />M. ALL THREE (3) PHASE POWER CONNECTIONS TO BE ON A FOUR (4) WIRE SYSTEM, AND ALL SINGLE <br />(1) PHASE POWER CONNECTIONS TO BE ON A THREE (3) WIRE SYSTEM, UNLESS SPECIFIED <br />OTHERWISE. <br />N. ALL WORK, RELATING TO THE INSTALLATION & HOOKUP OF THE SPECIFIED EQUIPMENT, IS TO BE <br />MEET WITH ALL OTHER GOVERNMENTAL REGULATORY REQUIREMENTS. <br />0. ELECTRICAL CONTRACTOR IS REQUIRED TO FURNISH AND INSTALL ALL ELECTRICAL COMPONENTS <br />NECESSARY TO PROVIDE SERVICE TO LOCATIONS & EQUIPMENT SHOWN ON THE DRAWINGS UNLESS <br />NOTED OTHERWISE. E.C. IS ALSO RESPONSIBLE FOR MAKING FINAL CONNECTIONS TO EQUIPMENT <br />SUPPLIED AND INSTALLED BY K.E.C. <br />P. PROVIDE A 4"x4" OUTLET BOX AND OUTLETS WITH 3/4" CONDUIT STUBBED INTO ACCESSIBLE CEILING <br />WITH PULL CORD FOR EACH TELEPHONE/DATA OUTLET. ALL OUTLETS SHALL BE FULLY INSTALLED <br />TESTED FOR POLARITY AND IN WORKING ORDER AS PART OF FINISHOUT ELECTRICIAN'S SCOPE. <br />Q. REFER TO ELECTRICAL RISER DIAGRAM, SHEET E3.0 FOR GROUNDING. <br />R. ELECTRICAL CONTRACTOR SHALL VERIFY WITH OWNER / SECURITY VENDOR WHETHER SECURITY <br />J—BOXES REQUIRE HARDWIRING OF CEILING MOUNTED CAMERAS OR RECEPTACLES FOR THE CAMERAS <br />TO PLUG INTO. SECURITY J—BOXES SHALL BE FLUSH MOUNTED TO CEILING. J—BOX/RECEPTACLE <br />FACE PLATES IN CEILING SHALL BE WHITE, UNLESS DIRECTED OTHERWISE ON ARCHITECTURAL PLANS. <br />S. FURROUT WALLS FOR ELECTRICAL AND PLUMBING AS NEEDED, OR WHERE REQUIRED BY LANDLORD <br />FOR ELECTRICAL AND PLUMBING CONNECTIONS. <br />T. CONFIRM FINISH OF ELECTRICAL COVERPLATES FOR OUTLETS & SWITCHES WITH ARCHITECTURAL <br />FINISH SCHEDULES <br />U. THE ELECTRICIAN SHALL PULL THE LOW VOLTAGE PERMIT IF REQUIRED BY THIS A.H.J. <br />V. REFER TO SHEET MEP1.0 FOR POWER FOR ROOF —MOUNTED EQUIPMENT. <br />W. FIRE ALARM DESIGN IS NOT PART OF THE MEP ENGINEER'S SCOPE. THE FIRE ALARM CONTRACTOR <br />SHALL BE RESPONSIBLE FOR MAKING MODIFICATIONS TO EXISTING FIRE ALARM SYSTEM, INCLUDING <br />TESTING AND INSPECTING SYSTEM COMPONENTS WITHIN LEASE SPACE SUCH AS DUCT SMOKE <br />DETECTORS, ETC. <br />X. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE KITCHEN APPLIANCE CONTRACTOR AND <br />SHALL PROVIDE ALL HARDWARE AND CONNECTIONS AS REQUIRED. <br />Y. ALL ELECTRICAL OUTLETS UNDER HOOD SHALL BE EQUIPPED WITH A SHUNT TRIP BREAKER, OR <br />EQUAL. INTERLOCK SHUNT WITH ANSUL SYSTEM. <br />Z. ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND SEALED WITH WHITE <br />SILICONE CAULKING. <br />AA. TO PROVIDE HANDLE TIE ON ALL MULTIWIRE BRANCH CIRCUITS PER NEC 210.4 (B). <br />AB. ALL SPARE CIRCUIT BREAKERS AND DISCONNECT SWITCHES SHALL BE LEFT IN THE OFF POSITION. <br />AC. E.C. SHALL VERIFY THE VOLTAGE AND AMPERAGE REQUIREMENTS OF ALL EQUIPMENT DELIVERED TO <br />THE SITE PRIOR TO CONNECTION. E.0 SHALL NOTIFY OWNER OF ANY DISCREPANCIES. <br />AD. PROVIDE (2) PULL STRINGS IN EACH EMPTY CONDUIT FOR DATA/PHONE LINES. <br />AE. ALL CONDUITS MUST NOT BE MOUNTED ON WALL SURFACES ANYWHERE IN EXPOSED AREAS. ALL <br />CONDUITS SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN WALLS. <br />AF. COORDINATE ALL LINES TO RUN CONCEALED. PUNCH DOWN BLOCK SHOULD BE ABOVE DROP CEILING. <br />AG. ALL DATA CABLES TO TERMINATE ON RJ45 CATEGORY 5e JACKS AND WIRE TO EIA/TIA 568—B.1 <br />STANDARDS. <br />AH. ALL DATA CABLES TO HOMERUN AND TERMINATE ON CATEGORY 5e EIA/TIA 568—B RJ45 PATCH <br />PANELS THE NETWORK CABINET. <br />Al. ALL CABLES TO BE CONTINUITY TESTED FOR POLARITY AND CORRECT PIN CONFIGURATION AND <br />MACHINE LABELED. <br />AJ. ALL WIRING IN EXPOSED AREAS MUST BE IN RIGID CONDUIT AND SPACED NO LOWER THAN 1 1/2- <br />BELOW THE DECK. IF TRUSSES, JOISTS, OR BEAMS ARE PRESENT WHICH PROHIBIT CONDUIT RUNNING <br />TIGHT TO DECK THAN THE CONDUIT MUST BE RAN TIGHT TO THE BOTTOM OF THE TOP CHORD OF <br />THE STRUCTURAL MEMBER. <br />AK. ANY PRE—EXISTING MC CABLE EXPOSED MUST BE REPLACED WITH RIGID CONDUIT. CONDUIT AND <br />J—BOXES MUST NOT BE MOUNTED ON WALL SURFACES ANYWHERE IN EXPOSED AREAS. ALL CONDUIT <br />SERVING DEVICES IN EXTERIOR WALLS MUST BE CONCEALED WITHIN WALLS. <br />AL. EXACT LOCATION OF MECHANICAL, PLUMBING, KITCHEN, FURNITURE SYSTEMS, OWNER FURNISHED <br />EQUIPMENT, ETC THAT REQUIRE ELECTRICAL CONNECTIONS ARE SHOWN ON THE MECHANICAL, <br />PLUMBING AND/OR ARCHITECTURAL DRAWINGS. COORDINATE EXACT LOCATIONS WITH RESPECTIVE <br />CONTRACTORS AND/OR VENDORS PRIOR TO ANY ROUGH —INS. <br />AM. REVIEW AND COORDINATE WITH ALL TRADES CONTRACT DOCUMENTS TO DETERMINE SPECIFIC <br />MOUNTING LOCATIONS FOR EQUIPMENT WITH ELECTRICAL CONNECTIONS. COORDINATE EXACT <br />MOUNTING LOCATIONS WITH THE SPECIFIC TRADE AND ARCHITECT. <br />WIRE SIZING <br />SCHEDULE <br />CIRCUIT <br />BREAKER <br />COPPER WIRE SIZE <br />(INCLUDES NEUTRAL) <br />20 <br />AMP <br />4#12, #12GR., Y2"C. <br />25 <br />AMP <br />4#12, #12GR., Y2"C. <br />30 <br />AMP <br />4#10, #1 OGR., 3/4 "C. <br />35 <br />AMP <br />4#8, #1 OGR., -Y4"C. <br />40 <br />AMP <br />4#8, #1 OGR., 3/4"C. <br />45 <br />AMP <br />4#6, #1 OGR., 1 "C. <br />50 <br />AMP <br />4#6, #1 OGR., 1 "C. <br />55 <br />AMP <br />4#6, #1 OGR., 1 "C. <br />60 <br />AMP <br />4#4, #1 OGR., 1Y4"C. <br />65 <br />AMP <br />4#4, #8GR., 1Y4"C. <br />70 <br />AMP <br />4#4, #8GR., 1Y4"C. <br />80 <br />AMP <br />4#3, #8GR., 1Y4"C. <br />90 <br />AMP <br />4#2, #8GR., 1 X "C. <br />100 <br />AMP <br />4#2, #8GR., 1Y4"C. <br />125 <br />AMP <br />4#1, #8GR., 1Y2"C. <br />150 <br />AMP <br />4#1 /0, #6GR., 2"C. <br />200 <br />AMP <br />4#3/0, #6GR., 2"C. <br />225 <br />AMP <br />4#4 0, #4GR., 2 C. <br />250 <br />AMP <br />4#250KCM, #4GR., 2 C. <br />400 <br />AMP <br />4#600KCM, #3GR., 3Yz"C. <br />NOTE: <br />CONTRACTOR TO INCREASE WIRE SIZING FOR <br />LONG RUNS OF WIRING FOR VOLTAGE DROP <br />ALLOWANCE. VOLTAGE DROP SHALL NOT <br />EXCEED 3 PERCENT. <br />POWER REOUIREMENTS FOR WALK-IN COOLER AND FREEZER: <br />INSTALL WALK—IN COOLER AND CHILLER (FREEZER) PER MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. ADJUST NUMBER AND SIZE OF BREAKERS AS NEEDED. VERIFY BREAKER AND <br />DISCONNECT PER MANUFACTURER'S NAMEPLATE INFORMATION. PROVIDE ALL NECESSARY AND <br />REQUIRED CABLES AND CONNECTIONS. <br />G.C. TO VERIFY ALL SPECIFICATION INSTALLATION REQUIREMENTS FOR WALK—IN COOLER / <br />FREEZER WITH OWNER. LOCATION AND INSTALLATION OF CONDENSER UNITS VARY PER <br />WALK—IN UNIT SIZE AND WITH BUILDING STRUCTURAL CAPACITY. <br />WHERE EXISTING WALK—INS ARE BEING REUSED, VERIFY NAMEPLATE DATA AND INSPECT POWER <br />SUPPLY. UPGRADE/REPAIR AS NECESSARY. A W.I.0 CONSULTANT SHALL BE HIRED TO FULLY <br />SERVICE WALK INS AND BRING TO FULL —WORKING ORDER. <br />POWER LEGEND <br />MARK <br />DESCRIPTION <br />DUPLEX OUTLET AT 18" A.F.F. <br />(U.N.O.) <br />SPECIALTY PLUG — OTHER <br />-e <br />THAN 11OV. REFER TO PANEL <br />SCHEDULE. <br />QUAD OUTLET AT 18" A.F.F. <br />(U.N.O.) <br />J—BOX <br />E::1 <br />ELECTRICAL DISCONNECT <br />PHONE <br />D <br />DATA <br />NOTES BY SYMBOL: <br />OPANELS 'A', 'B' ARE EXISTING AND OPEN INTO ROOM. REUSE <br />IN PLACE. <br />O24"x24"0/4" PLYWOOD SHELF AT HEIGHT INDICATED PER <br />PLANS WITH DUPLEX RECEPTACLE FOR TELEPHONE SYSTEM. <br />ELECTRICAL CONTRACTOR TO PROVIDE TELEPHONE CONDUIT <br />FROM LANDLORD'S DEMARC AS NEEDED. <br />OALL 15A AND 20A 120V OUTLETS IN KITCHEN AND PREP <br />AREA AND ALL OUTLETS WITHIN 6 FEET OF THE OUTSIDE <br />EDGE OF A SINK TO BE GFCI PROTECTED, PER NEC 210.8(B). <br />O4 CONTRACTOR SHALL INTERLOCK EF-1 AND RTU(S) (FANS), <br />SO THAT FANS (AND O.A. SUPPLY) RUN CONTINUOUSLY <br />WHEN EF-1 IS OPERATING. THE RTU COMPRESSORS SHALL <br />CYCLE AS NEEDED. <br />OEF-1 SHALL BE ROOF —MOUNTED TYPE. REFER TO M1.0, <br />MEP1.0 FOR ADDITIONAL INFORMATION. <br />O6 ISOLATED GROUND RECEPTACLE. <br />OWALK—IN COOLERS ARE EXISTING TO REMAIN. ELECTRICAL <br />CONTRACTOR MAY REUSE EXISTING BREAKERS WHERE <br />POSSIBLE. <br />O8 PROVIDE INSECT CONTROL (FLY LIGHT) RECEPTACLE AT 84" <br />AFF. <br />Og FURROUT WALLS FOR POWER AS NECESSARY. <br />10 POWER FOR EXISTING WALK—INS IS ESTIMATED. CONFIRM <br />AND REUSE EXISTING POWER SUPPLY, EXCEPT UPGRADE IF <br />FOUND TO NOT CONFORM TO EQUIPMENT NAMEPLATE DATA. <br />11 POWER FOR EXISTING EVAPORATOR COILS DERIVED FROM <br />MAC UNIT. REFER TO SHEET MEP 1.0 FOR CIRCUITS AND <br />ADDITIONAL DETAILS. NO CHANGES EXPECTED TO THIS <br />EXISTING EQUIPMENT. <br />ELECTRICAL POWER NOTES (CONTINUED) <br />AN. MINIMUM CONTRACTOR SIZE FOR 120V BRANCH CIRCUITS SHALL BE <br />12—AWG. FOR 120V BRANCH CIRCUITS WITH HOMERUNS OVER 100 <br />LINEAR FEET, A MINIMUM WIRE SIZE OF 10—AWG SHALL BE <br />PROVIDED FROM FIRST JUNCTION/OUTLET BOX TO BRANCH CIRCUIT <br />PANELBOARD. <br />AO. ALL WIRING SHALL BE IDENTIFIED BY PANELBOARD AND CIRCUIT <br />NUMBER(S) IN ALL CABINETS, <br />JUNCTION BOXES, WIRING TROUGHS, ENCLOSURES, SPLICE OR <br />TERMINATION POINTS, ETC. <br />AP. TYPED PANELBOARD DIRECTORY CARD SHALL BE PROVIDED FOR ALL <br />PANELS INSTALLED UNDER <br />THIS CONTRACT. NEW DIRECTORY CARDS SHALL BE LOCATED ON THE <br />INSIDE DOOR OF ASSOCIATED <br />PANELS. <br />AQ. IN THE EVENT THAT EXTRA BREAKER SPACES ARE NEEDED, THE E.C. <br />SHALL USE CONTACTOR(S) IN <br />LEIU OF SHUNT TRIP BREAKERS TO DISCONNECT POWER FOR <br />EQUIPMENT BENEATH THE HOOD. <br />AR. PROVIDE POWER FOR SPEAKERS BASED ON OWNER'S FINAL A/V <br />PACKAGE. A/V RECEIVER TO BE AT MANAGER'S DESK. <br />AS. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL CONNECTIONS AND <br />ENSURE ALL OUTLETS ARE INSTALLED WITHIN REACH OF THE <br />CORD/PLUG OF THE EQUIPMENT INTENDED TO SERVE. <br />r/ <br />a <br />J <br />3 <br />HOMERUNS AND <br />BRANCH <br />WIRING <br />FOR 20 AMP CIRCUITS <br />SHALL <br />BE <br />AS FOLLOWS: <br />LENGTH CIRCUIT <br />WIRE <br />SIZE <br />HOMERUN <br />WIRE SIZE <br />1FT <br />TO <br />50FT <br />NO.12 <br />AWG <br />NO.12 <br />AWG <br />51 FT <br />TO <br />75FT <br />NO.12 <br />AWG <br />NO.10 <br />AWG <br />76FT <br />TO <br />120FT <br />NO.10 <br />AWG <br />NO.8 <br />AWG <br />121 FT <br />TO <br />19OFT <br />NO.10 <br />AWG <br />NO.6 <br />AWG <br />191FT <br />TO <br />30OFT <br />NO.10 <br />AWG <br />NO.4 <br />AWG <br />WALMART STORE <br />PLAN <br />NORTH <br />1 POWER PLAN <br />SCALE: 1/4" = 1'-0" <br />:5 <br />Peter A. Leptuch, P.E. <br />300 N. Carroll Blvd. #200 <br />Denton, TX 76201 <br />(940) 735-5127 <br />r/ <br />w <br />0 <br />Q <br />J <br />3 <br />!HEAD SOFFIT <br />TYP. FOR ALL <br />MONITOR/ TVS. <br />StudioRG,._ <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F: 631.226.7175 <br />© Copyright 2018: RGBK, INC. <br />Lan,dry <br />ARCHfTECfURE PLANNING INFO" DESIGN <br />1202 Richardson Dr. #106 Tel: 214.631.6941 <br />Richardson, Texas 75080 Fax: 214.634-1814 <br />Seal: <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />POWER PLAN <br />E1.0 <br />