q [ci on i i i g a tu zi <br />OMEN <br />pas <br />op <br />F91,0A <br />111150 <br />, , <br />raoAp <br />zrnm� <br />WAWA <br />iof <br />ELECTRICAL POWER NOTES <br />A. JURISDICTIONS VARY AS TO WHO CAN MAKE FINAL CONNECTION OF SIGN TO BUILDING POWER. <br />SOME JURISDICTIONS REQUIRE SPECIAL SIGN PERMITS. THE ELECTRICAL CONTRACTOR SHALL <br />PROVIDE AN ACCESSIBLE J-BOX AT BUILDING PERIMETER FOR EACH SIGN LOCATION ON ALL JOBS <br />WITH MEANS OF DISCONNECT AND CONDUCTOR BACK TO THE PANEL, PER NEC. THE SIGN <br />CONTRACTOR SHALL PROVIDE ALL SIGNS WITH A SINGLE WHIP POKING THROUGH THE BACK OF THE <br />SIGN OR SIGN RACEWAY FOR EACH SIGN LOCATION. FINAL CONNECTION (INCLUDING ANY CONDUIT <br />ABOVE METAL AWNING/ STRUCTURE OR OTHER SPECIAL 'GAP' SITE CONDITIONS) SHALL BE BY <br />ELECTRICAL CONTRACTOR UNLESS THE A.H.J. REQUIRES THIS CONNECTION TO BE BY THE SIGN <br />CONTRACTOR. <br />B. AT TIME OF ORDER OF LIGHT FIXTURES, CONFIRM ALL NEW FIXTURES ARE DIMMABLE. <br />C. BACK OF HOUSE SWITCHES SHALL BE DUAL TECHNOLOGY VACANCY SENSOR TYPE. <br />D. E.C. SHALL COORDINATE FULLY WITH OTHER CONTRACTORS ASSOCIATED WITH THIS PROJECT TO <br />VERIFY ALL EQUIPMENT LOCATIONS, CONNECTION REQUIREMENTS, ELEVATIONS AND LOCATIONS OF <br />PIPES, CONDUITS AND DUCTS TO PREVENT CONFLICTS DURING CONSTRUCTION. ANY RELOCATION OR <br />REROUTING OF EQUIPMENT, PIPES, CONDUITS, DUCTS OR MATERIALS RESULTING FROM A LACK OF <br />COORDINATION BETWEEN CONTRACTORS WILL BE AT THE CONTRACTORS EXPENSE. <br />E. EQUIPMENT ROUGH -INS SHOWN ARE ACCURATE TO THE BEST OF DESIGNER'S KNOWLEDGE. HOWEVER, <br />IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY <br />VARY FROM WHAT IS SHOWN. THEREFORE,THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS <br />WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE E.C. TO VERIFY THESE DIMENSIONS <br />SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE <br />CONTRACTOR. <br />F. E.C. SHALL FURNISH AND INSTALL ALL REQUIRED DISCONNECT SWITCHES AND MOTOR STARTERS TO <br />ALL EQUIPMENT. <br />G. E.C. SHALL REVIEW WITH OWNER AND SIGNAGE MANUFACTURER, REQUIREMENTS AND LOCATION OF <br />BUILDING SIGNAGE PRIOR TO CONSTRUCTION AND PROVIDE 120VAC CONNECTION AS REQUIRED. <br />H. E.C. SHALL PROVIDE AS -BUILT DRAWINGS AT JOB COMPLETION TO ARCHITECT. <br />I. ALL WORK SHALL BE INSTALLED PER ALL GOVERNING CODES. <br />J. SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS <br />INCLUDING RESTROOM FIXTURES. BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. <br />K. SUBCONTRACTOR IS TO SUPPLY AND INSTALL UNISTRUT AND 3/8" THREADED ROD TO <br />HANG/SUPPORT LIGHTING. <br />L. RACEWAY SYSTEMS: ALL BRANCH CIRCUIT WIRING SHALL BE ROUTED IN EMT, RIGID OR ELECTRICAL <br />METALLIC TUBING. USE STEEL SET SCREW TYPE FITTINGS ON ALL EMT. <br />M. CONDUIT SHALL BE SUPPORTED AT INTERVALS PER NEC REQUIREMENTS AND SHALL BE SECURELY <br />FASTENED TO BUILDING WITH AN APPROVED FASTENING SYSTEM. <br />N. ALL NEW CONDUIT TO BE CONCEALED IN WALLS. PATCH/PAINT IF NECESSARY. WIRING, WIRING <br />DEVICES, PLATES AND GROUNDING <br />0. ALL WIRING SHALL CONSIST OF COPPER CONDUCTORS WITH THERMOPLASTIC INSULATION RATED FOR <br />SIX HUNDRED (600) VOLTS. ALL WIRING INSULATION SHALL BE HEAT AND MOISTURE RESISTANT <br />TYPES THW, THWN, OR THHN FOR INTERNAL AND DRIVE LOCATIONS. WIRE COLOR SHALL FOLLOW NEC <br />STANDARDS, PER VOLTAGE. <br />P. MINIMUM CONDUCTOR SIZE SHALL BE NO. 12 AWG FOR ALL BRANCH CIRCUITS (I.E. RECEPTACLES, <br />LIGHTING, EQUIPMENT POWER, ETC.). MINIMUM CONDUCTOR SIZE SHALL BE NO. 10 AWG FOR ALL <br />FEEDER CIRCUITS TO MECHANICAL EQUIPMENT (LE U-1, CONDENSERS, ETC.) <br />Q. ALL SPLICED OR CONNECTIONS SHALL BE MADE IN OUTLET BOXES, JUNCTION BOXES OR EQUIPMENT <br />WHERE ACCESSIBLE, AND NOT BELOW GRADE. <br />R. CONDUCTORS SHALL BE PULLED WITHOUT THE USE OF OIL OR GREASE. WIRE PULLING LUBRICANTS <br />WHICH ARE APPROVED FOR USE WITH CONDUCTOR INSULATION MAY BE USED. CARE SHALL BE <br />TAKEN IN PULLING WIRE TO ASSURE THAT MAXIMUM ALLOWABLE PULLING TENSION OF WIRE IS NOT <br />EXCEEDED. WIRING WITH DAMAGED CONDUCTORS OR INSULATION WILL NOT BE ACCEPTED. <br />U. SWITCHES FOR LIGHTING CONTROL SHALL BE INDUSTRIAL GRADE. DEVICES AND PLATES <br />TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS PLATES IN THE <br />KITCHEN AND RESTROOMS. UNLESS NOTED AS OTHERWISE, REFER TO ARCHITECTURAL FINISH <br />SHEETS. SIDE WIRED ONLY, TWENTY (20) AMP, ONE HUNDRED <br />TWENTY/TWO HUNDRED SEVENTY-SEVEN (120/277) VOLT. <br />V. DUPLEX RECEPTACLES SHALL BE INDUSTRIAL GRADE, THREE (3) WIRE GROUNDING, WHITE <br />COLOR, FINDER GROOVE, TWENTY (20) AMP, NEMA 5-20R 125 VAC. <br />W. PLATES SHALL BE FURNISHED AND INSTALLED FOR ALL WIRING DEVICES, TELEPHONE <br />OUTLETS, JUNCTION BOXES, ETC. MATCH SWITCHPLATE COVERS AS LAID OUT ABOVE. <br />X. E.C. SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL BRANCH CIRCUITS <br />BETWEEN THE PHASES OF THE SYSTEM; REGARDLESS OF CIRCUITING INDICATED. <br />ELECTRICAL POWER NOTES (CONTINUED) <br />Y. ALL DUPLEX RECEPTACLES INSTALLED IN KITCHEN, BEVERAGE, AND <br />PREPARATION AREA ARE TO BE <br />GFCI RATED, WHERE NOT PROTECTED BY A GFCI CIRCUIT BREAKER. <br />Z. THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH <br />IN ANY EXPOSED <br />AREA OR AREAS VISIBLE TO THE CUSTOMER. ANY HORIZONTAL <br />CONDUIT MUST BE LEVEL. <br />NOTES BY SYMBOL: <br />OJ-BOX FOR SIGN(S), VERIFY EXACT LOCATION AND HEIGHT WITH <br />SIGN VENDOR. SIGN CONTROLLED BY 7 DAY PROGRAMMABLE <br />TIME CLOCK. REUSE EXISTING CONDUIT/CIRCUIT FROM PREVIOUS <br />TENANT'S SIGN LOCATION FOR NEW TENANT'S SIGN. <br />OEMERGENCY LIGHTS, NIGHT LIGHTS, AND EXIT SIGNS SHALL BE <br />WIRED AHEAD OF SWITCHING (NOT SWITCHED) TO NEAREST <br />LIGHTING CIRCUIT. <br />OSWITCH BANK CONSISTING OF SWITCHES UNDER COMMON <br />FACEPLATES FOR CONTROL OF LIGHTING, MOUNTED AT A <br />MAXIMUM OF 48" AFF. LABEL EACH SWITCH PER AREA SERVED <br />WITH STATUS INDICATOR, PER ENERGY CODE. REFER TO <br />ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION. <br />O REUSE EXISTING WALK-IN FREEZER/COOLER LIGHTS. <br />O INSTALL HOOD LIGHTS THAT ARE SHIPPED LOOSE. VERIFY <br />CONFIGURATION WITH VENDOR. <br />FIXTURE MOUNTED ON EXTERIOR WALL ABOVE DOOR. IF NOT <br />CD <br />PRESENT, FOR EXTERIOR EGRESS LIGHTING. ASSUMED TO BE <br />EXISTING. PROVIDE IF NOT PRESENT. <br />THERE IS NO EXTERIOR DAYLIGHTING ZONE. DAYUGHTING IS NOT <br />REQUIRED. <br />THIS PROJECT IS AN INTERIOR REMODEL OF AN EXISTING WALMART STORE <br />LEASE SPACE. THE SPACE IS BEING DELIVERED TO CONTRACTOR IN AS -IS <br />CONDITION. ALL WORK TO COMPLETE AND DELIVER A FULLY OPERATIONAL <br />SPACE IS BY THE G.C. THE G.C. SHALL VISIT THE JOB SITE PRIOR TO BID <br />AND SHALL SUPPLEMENT WHAT IS SHOWN IN THIS DOCUMENT SET WITH <br />FIELD OBSERVATIONS TO ENSURE AN ACCURATE BID. <br />*ALL FIXTURES <br />SHALL BE <br />DIMMABLE AND <br />ALL SHALL BE <br />PROVIDED WITH <br />A WALL DIMMER <br />SWITCH. <br />TYPICAL <br />SWITCH <br />INDICATES (5) <br />CIRCUIT NUMBER <br />(�J <br />FIN. FLOOR <br />B-2 <br />B-2 <br />B-4 <br />B-4 <br />SPARE <br />a <br />a <br />a <br />a <br />a <br />a <br />b <br />C <br />d <br />— <br />LIGHTS � LIGHTS J <br />(2X4) ACCENT <br />2 SWITCH BANK O <br />SCALE: NOT TO SCALE <br />Q <br />J <br />3r <br />B• <br />VIA <br />/ 4"C. <br />OUTDOORS <br />U—ti <br />VI A T/C <br />�WALMART STORE <br />LIGHTING PLAN <br />SCALE: 1 /4" = 1'-0" <br />Peter A. Leptuch, P.E. <br />300 N. Carroll Blvd. #20 <br />Denton, TX 76201 <br />(940) 735-5127 <br />w <br />0 <br />N <br />StudioRG_ <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F:631.226.7175 <br />© Copyright 2018: RGBK, INC. <br />Seal: <br />Landry <br />_ GREG LANDRY <br />AKWEMURE MANNING INTO" DESIGN <br />1202 Richardson Dr. #'106 Tel. 214.631.6941 <br />Rchardsan, Texas 75080 Fax: 214.634.1814 <br />v��¢,.•�EN3 •fir <br />No 72679 <br />..a;'. S;pT JF .'441;' <br />V� <br />I'�• <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />LIGHTING PLAN <br />E2.0 <br />