LEAVE CLEAN OUT OPEN <br />GALVANIZED PIPE <br />4» 4' <br />GALVANIZED PIPE STRAP ONE <br />CONDENSATE TRAP ASSEMBLY FOR VENTING <br />STRAP. FIT TIGHT <br />SIZE LARGER THAN PIPE <br />FURNISHED BY RTU <br />TO PIPE. <br />STAINLESS STEEL <br />MANUFACTURER. <br />i WRAP MEMBRANE <br />i <br />ADJUSTABLE HOSE CLAMP <br />4" REDUCER INDIRECT <br />AROUND BLOCKING <br />(BOTH SIDES) <br />CONNECTION. <br />FULL LAP AT TOP <br />7771 <br />GAS LINE PAINTED <br />GAS LINE PAINTED <br />PROVIDE NIPPLE LENGTH <br />REF ARCH7 <br />REF ARCH <br />SUCH THAT REDUCER IS <br />ROOF MEMBRANE <br />ROOF MEMBRANE <br />PLACED AS HIGH AS POSSIBLE NOTE: USE THIS DETAIL AT THE <br />ROOF INSULATION <br />ROOF INSULATION <br />START OF EVERY MAIN LINE <br />REF ROOFTOP PIPE <br />I s <br />I <br />t <br />BLOCKING DETAIL <br />PIPE PLUG <br />GALVANIZED TEE <br />ELEVATION <br />ELEVATION <br />REF PLAN <br />1 1 /2" ZINC COATED <br />1 1 /2" ZINC COATED <br />LAG SCREWS TYP <br />LAG SCREWS TYP <br />TREATED WOOD BLOCKING: <br />TREATED WOOD BLOCKING: <br />ROOF <br />6X6X12 FOR GAS PIPING, <br />6X6X12 FOR GAS PIPING, <br />NOTE: THIS CLEAN OUT IS TO BE <br />INSTALLED EVERY 100 FT IN <br />Y2" MIN <br />TYP <br />2X4X12 FOR CONDENSATE <br />X" MIN <br />TYP <br />2X4X12 FOR CONDENSATE <br />PIPING - 8'-0" OC MAX <br />PIPING - 8'-0" OC MAX <br />THE MAIN LINE AND SHOULD <br />z <br />BE IN THE MIDDLE OF ALL <br />O <br />60 MIL MEMBRANE o_ <br />I <br />60 MIL MEMBRANE <br />FEEDERS OVER 50 FT LONG <br />Q <br />i <br />EXTEND MIN 1 2" ~ i <br />EXTEND MIN 1 /2 " <br />RTU CONNECTION <br />CLEAN OUTS <br />J <br />i <br />i <br />BEYOND END OF w i <br />BEYOND END OF <br />w <br />i <br />WOOD BLOCKING w <br />WOOD BLOCKING <br />1 <br />I <br />I <br />1 <br />I <br />10 <br />1 <br />1 <br />7 CONDENSATE <br />DRAINZSUPPORT <br />PIPE <br />DIAMETER <br />LESS THAN 2 PIPE DIAMETER <br />R <br />REATER <br />GREATER <br />NTS <br />01.28.05 MECH27 <br />TOP PIPE <br />BLOCKING <br />6(--`-)-ROOF <br />NTS 03.28.14 MECH2-3 <br />RTU (AHU SIM) <br />BRACKET <br />CHOOSE <br />TOP OR <br />#12 TEK SCREWS BOTTOM <br />(TYP EIGHT PER ROW <br />BRACKET) <br />NEW CURB <br />ADAPTER <br />REF SUPPLIER FOR <br />CURB ADAPTER TO <br />EXISTING CURB <br />CONNECTION TYP <br />PROVIDE MIN <br />CONNECTION OF #10 <br />TEK SCREWS AT 6"OC. <br />SUPPI. <br />PLENI` <br />SIZE <br />UNIT <br />JOIST <br />CURB <br />RTU (AHU SIM) <br />BRACKET <br />#10 TEK SCREWS <br />(TYP EIGHT PER <br />BRACKET) <br />RTU BRACKET <br />ATTACHMENT <br />CHOOSE <br />TOP OR <br />BOTTOM <br />ROW <br />mil w1 4w1-1 1 <br />MUNTERS AHU BRACKET LAYOUT <br />(OTHER MANUFACTURERS SIMILAR <br />10 GA <br />GALV <br />TYP <br />10 GA �18 GA GALV <br />GALV TYP STRAP TYP <br />MUNTERS AHU BRACKET <br />,(OTHER MANUFACTURERS SIMILAR) <br />BRACKET d <br />TYP _ <br />ROOF <br />II <br />3 & 10 TON <br />RTU WITH CURB ADAPTER 5 TON <br />BRACKET ATTACHMENT <br />03/16 <br />SCREW HOLES <br />FOUR PER ROW <br />EQ SPACED <br />TYP CHOOSE TOP OR <br />BOTTOM ROW <br />8 GA <br />GALV STRAP <br />LENNOX TYP <br />LENNOX RTU BRACKET LAYOUT RTU BRACKET <br />NOTE: USE 6 ANCHOR BRACKETS FOR RTU'S (3, 5, 10, 20 TON) ON ALL STORES EXCEPT WHERE LOCATED WITHIN 1500 FEET OF A SHORELINE <br />OR COASTLINE (A SHORELINE IS ANY BODY OF WATER THAT WIND CAN FLOW FOR A DISTANCE OF AT LEAST 1 MILE). FOR THESE RTU <br />INSTALLATIONS, USE 8 ANCHOR BRACKETS FOR 3, 5, AND 10 TON RTU'S AND USE 10 ANCHOR BRACKETS FOR 20 TON RTU'S. FOR EACH <br />AHU, PROVIDE A MINIMUM OF 8 (12 RECOMMENDED) ANCHOR BRACKETS. ANCHOR BRACKETS ARE FURNISHED BY AES INDUSTRIES, INC. <br />BRACKET CONSTRUCTION, QUANTITIES, AND SPACING SHOWN ON THIS DETAIL ARE FOR GENERAL COORDINATION ONLY. INSTALL BRACKETS <br />ACCORDING TO CURB MANUFACTURER/BRACKET SUPPLIER'S INSTALLATION INSTRUCTIONS AND PER ALL LOCAL CODES. COORDINATE FINAL <br />BRACKET LOCATIONS WITH EQUIPMENT. DO NOT OBSTRUCT OPENING OR UTILITY CONNECTIONS. <br />RTU/AHU ANCHOR BRACKETS <br />5 NTS 08.18.10 MECH2.1-11 TOP BEAM <br />RETURN DUCT <br />WHEN SHOWN <br />ON PLAN <br />PROVIDE 3/4" FLANGED <br />FRAME. HARDWARE CLOTH <br />(1"xl" GRID) SECURE <br />WITH CONTINUOUS 1" <br />GALVANIZED STRAPS <br />AND SCREWS 8" OC. <br />PROVIDE 48"x22" OPENING <br />AWAY FROM SUPPLY PLENUM <br />FOR 20-TON, 36"x20" <br />OPENING FOR 10-TON, AND <br />24"x14" FOR 3-AND <br />5-TON RTUS. <br />NU I L: RUU i L UUC I AS HIGH AS PUSSIBLIE t3LLUW RETURN PLENUM ABOVE <br />JOIST GIRDER WHILE MAINTAINING A MINIMUM OF BOTTOM OF JOISTS <br />18" BELOW ROOF JOISTS. FOLLOW ROOF SLOPE <br />RTU DUCTWORK DETAIL. <br />4 NTS 10.26.07 MECH2-6 <br />L L = W/4, 4" MIN <br />O� <br />SPIN -IN FITTINGS <br />W/SCOOPS ARE <br />NOT ACCEPTABLE <br />45' LEAD IN <br />BRANCH <br />REF PLANS FOR <br />RUNOUT SIZES <br />DUCT FITTING <br />CLAMP TYP <br />TOP CHORD OF JOIST <br />3" ROOF <br />MAX ROOF <br />2%2"x1/4" ANGLE OR <br />6 1 5/8"xl 5/8" UNISTRUT 6 <br />HANGER STRAP <br />LOADS MUSJB <br />HUNG WITHIN ::7 THREADED ROD <br />OF PANEL PTYP 1" MIN. SHEET METAL <br />OF EXISTING SCREWS TYP <br />>< <br />STRUCTURAL <br />60" MAX. <br />RECTAZNGULAR DUCT <br />2"x2"x1/4" ANGLE OR <br />1 5/8"x1 5/8" UNISTRUT <br />BOTTOM OF RECTANGULAR DUCT RECTANGULAR DUCT <br />STRUCTURE PERPENDICULAR TO STRUCTURE PARALLEL TO STRUCTURE <br />OPTIONAL ROUTING <br />IN CONCEALED <br />AREAS <br />LOADS MUST BE <br />HUNG WITHIN 3" LOAD RATED <br />OF PANEL POINTS FASTENERS <br />3„ OF EXISTING <br />PROOF MAX STRUCITURAL JOISTS ROOF <br />6" <br />BOTTOM OF ROUND SUPPLY <br />STRUCTURE AIR DUCT <br />ER 2"x2%1 /4" ANGLE <br />TWIST STRAP S�P�� ��� OR 1 5/8"xl 5/8" <br />16 GAUGE GALV STEEL LOAD RATED �O UNISTRUT <br />BAND (2" WIDE) FASTENERS �6' <br />ROUND DUCT / <br />L SUPPLY REGISTER, REF FLOOR PLAN <br />FOR SIZE AND LOCATION, MOUNT <br />REGISTERS @ 30 DEGREE ANGLE IN STOCKROOM <br />AREA AND 15 DEGREE ANGLE IN SALES AREA, <br />EXCEPT THOSE SHOWN ON BOTTOM <br />OF DUCT ON THE PLAN <br />PERPENDICULAR TO JOIST PARALLEL TO JOIST <br />DUCT SUPPORT AND GRILLE. <br />NTS <br />02.24.12 <br />MECH2-lA <br />NATURAL GAS <br />MECHANICAL KEYNOTES <br />PIPING NOTES <br />15.703 ROUTE DUCTWORK TIGHT TO THE <br />1. CONTRACTOR SHALL COORDINATE ALL <br />BOTTOM OF STRUCTURE. COORDINATE <br />WITH OTHER DISCIPLINES. <br />DETAILS OF THE GAS PIPING SYSTEM <br />WITH THE LOCAL GAS COMPANY. THIS <br />15.711 REFER TO ARCHITECTURAL ROOF PLAN <br />INCLUDES, BUT IS NOT LIMITED TO, THE <br />AND STRUCTURAL PLANS FOR DETAILS <br />LOCATION OF THE GAS METER, GAS <br />OF ROOF CURB INSTALLATION. <br />PRESSURE REQUIREMENTS, RELOCATION <br />AND/OR UPSIZING OF EXISTING SERVICE <br />15.722 COORDINATE DUCT PENETRATIONS <br />PIPING IF REQUIRED. CONTRACTOR SHALL <br />THROUGH ROOF, AND ROUTING OF <br />PAY ALL COSTS REQUIRED BY GAS <br />DUCTWORK WITH CONDUITS, <br />COMPANY. CONTACT GAS COMPANY FOR <br />FIRE PROTECTION PIPING, LIGHTS <br />SIZE AND TYPE OF PIPING AND VALVES <br />AND STRUCTURE. <br />REQUIRED FOR CONNECTION TO METER. <br />GAS METER AND SERVICE REGULATOR TO <br />BE PROVIDED BY UTILITY COMPANY. <br />15.729 INSTALL ROOF CURB PER ROOF CURB <br />VERIFY CORRECT GAS PRESSURE <br />BOX NOTE. <br />DOWNSTREAM OF SERVICE REGULATOR <br />AFTER GAS UTILITY COMPLETES <br />INSTALLATION. THE NATURAL GAS <br />DEMAND SHOWN IN MBH IS BASED ON A <br />MECHANICAL SYMBOLS <br />HEATING VALUE OF 1000 BTU (1 MBH) <br />PER CUBIC FOOT, A SPECIFIC GRAVITY <br />OF 0.6, AND ON PRIMARY EQUIPMENT <br />SPECIFICATIONS IN SCHEDULES. GAS <br />18/12 <br />RECTANGULAR DUCT 18" WIDE <br />PIPING SIZES SHALL BE AS NOTED ON <br />BY 12" DEEP <br />PLANS. <br />2. NOT USED <br />12" <br />12" DIAMETER ROUND DUCT <br />3. NOT USED <br />® <br />SUPPLY DUCT IN SECTION <br />4. GAS AND CONDENSATE PIPING SHALL BE <br />MINIMUM 5'-0" CLEAR FOR ROOF TOP <br />RETURN OR EXHAUST DUCT IN <br />EQUIPMENT MAINTENANCE ACCESS. <br />SECTION <br />5. NOT USED <br />ELBOW WITH TURNING VANES <br />ROOF CURB NOTE <br />TEE WITH TURNING VANES <br />OWNER SHALL FURNISH AND THE CONTRACTOR <br />SHALL INSTALL ROOF CURB (AS MANUFACTURE <br />ROUND (OR OVAL) ELBOW <br />BY AES INDUSTRIES INC., CONTACT CHAD BUR <br />1-800-786-0402) FOR NEW ROOF TOP UNITS. <br />ROOF CURB SELECTION AND INSTALLATION <br />SHALL BE ADJUSTED FOR ROOF SLOPE TO <br />MAINTAIN LEVEL RTU INSTALLATION AND <br />VOLUME/BALANCE DAMPER <br />ADEQUATE CONDENSATE DRAINAGE. ROUTE NEW <br />CONDENSATE TO DRAIN AWAY FROM UNIT DOWN <br />SUPPLY AIR DIFFUSER WITH <br />ROUND SUPPLY DUCT <br />SIDE SLOPE OF ROOF. <br />SEE SPECIFICATION FOR ADDITIONAL <br />INFORMATION. <br />RETURN OR EXHAUST AIR DIFFUSER <br />WITH ROUND DUCT <br />CD <br />DIFFUSER OR GRILLE TYPE <br />12" <br />BRANCH DUCT AND/OR NECK SIZE <br />450 <br />CFM <br />�'JUH1 <br />THERMOSTAT <br />O <br />TIMER <br />S# <br />TEMP SENSOR <br />CONNECT TO EXISTING <br />ETR <br />EXISTING TO REMAIN <br />FD <br />FIRE DAMPER <br />6.9 - <br />RUN 1" <br />CONDENSATE PIPE <br />THROUGH <br />SECONDARY <br />OVERFLOW <br />SCUPPER DOWN TO <br />BELOW GRADE INTO <br />STORM WATER. <br />REF. 1-P1.1 FOR <br />CONTINUATION <br />V�z� <br />O"IL <br />0" <br />STOCKROOM <br />, N-M�- m m mm� <br />FFfiQ,P'`OF,..,,. <br />DUCTWORK AND ROUTE 2 (TYP) <br />„s IN STRUCTURE M1 - <br />t <br />Fti SAW <br />MOUNT AS TGW 6 7 12 8 <br />HIGH AS 12 12 M1 M1 SAW 275 <br />POSSIBLE ON _ _CONDENNEW SATE 18 10 (TYP 2) I I ry <br />BOTH SIDES (TYP 2) 550 I <br />OF WALL PIPE_--�a <br />� (TYP 4) <br />y CO <br />a._ <br />11�7 \ 0 <br />t <br />NEW <br />4 5 15.711 <br />M1 M1 15.722 RTU-36 I CO <br />15.72g 10 TON _ J <br />a <br />TAP OFF TOP <br />15.703 OF DUCTWORK <br />o AND ROUTE INI <br />STRUCTURE Lcat <br />m. <br />EAG1 <br />8" <br />COORDINATE DUCT 100 <br />TRANSITION WITH 61 6„ <br />Eft <br />CHANGE IN JOIST DEPTH t <br />6" <br />50 <br />S-36 I <br />6" <br />IHS ON ROOF 1 <br />LIQUOR SALES 15.711 <br />T CD1 I <br />y's 50 <br />SAW I MEN 6" <br />12 8 EAG1 <br />(TYP 2) 100 ri <br />GENERAL NOTES <br />1. GENERAL NOTES ARE APPLICABLE TO ALL 21. EXISTING PIPE SIZES AND LOCATIONS HAVE <br />MECHANICAL/PLUMBING DRAWINGS. NOT BEEN FIELD VERIFIED. CONTRACTOR IS <br />RESPONSIBLE TO FIELD VERIFY LOCATION AND <br />2. PROVIDE ALL MATERIALS FOR A COMPLETE SIZES OF ALL EXISTING PIPING THAT IS BEING <br />INSTALLATION IN ALL RESPECTS AND READY CONNECTED TO OR MODIFIED, AND TO VERIFY <br />FOR INTENDED USE AND IN STRICT THAT PROPER SLOPES AND ELEVATIONS ARE <br />ACCORDANCE WITH STATE AND LOCAL CODES AVAILABLE. MAINTAIN MINIMUM SLOPE OF <br />AND MANUFACTURERS RECOMMENDATIONS. 1 /8" PER FOOT FOR SAN SEWER PIPING 3" <br />OR LARGER. MAINTAIN MINIMUM SLOPE OF <br />3. STORE MUST BE KEPT IN OPERATION. 1 /4" PER FOOT FOR SAN SEWER PIPING <br />ARRANGE ALL WORK TO KEEP DISRUPTIONS SMALLER THAN 3". REF ARCH. FOR <br />TO STORE OPERATIONS TO A MINIMUM. TRENCHING REQUIREMENTS. <br />COORDINATE WITH EXISTING AND NEW <br />CONSTRUCTION. PAY ALL NECESSARY 22. PLUMBING CONTRACTOR SHALL VERIFY <br />FEES AND PERMITS. EXISTING SEWER AND VENT PIPE SIZE <br />AND ELEVATION AND SHALL VERIFY THAT <br />4. IF NEW CONSTRUCTION DISRUPTS PROPER SLOPES ARE AVAILABLE BEFORE <br />EXISTING UNDERGROUND SERVICES (GAS, CUTTING FLOOR SLAB FOR NEW SEWER <br />SEWER, DOMESTIC WATER, FIRE PIPING. <br />SPRINKLER, ETC.), PROVIDE ALL 23. PROVIDE ACCESS DOORS TO NEW WATER <br />MATERIALS AND LABOR AS REQUIRED TO VALVES AND CLEANOUTS AS NECESSARY <br />MAINTAIN THEIR PROPER OPERATION. WHEN INSTALLED IN INACCESSIBLE AREAS. <br />5. CONTRACTOR IS RESPONSIBLE FOR 24. PLUMBING CONTRACTOR SHALL PROVIDE <br />UTILIZING OWNER APPROVED ROOFING ONE YEAR WARRANTY FOR PROPER SEWER <br />CONTRACTORS FOR CUTTING AND SYSTEM OPERATION. <br />PATCHING ROOF. <br />6. CONTRACTOR SHALL FURNISH AND INSTALL 25. SANITARY DRAINAGE LINES AND FITTINGS <br />EXHAUST FANS AND EXHAUST FAN CURBS. (DRAIN, WASTE AND VENT) SHALL BE <br />CONTRACTOR SHALL INSTALL ALL CAST IRON, COATED INSIDE AND <br />STRUCTURAL SUPPORTS FOR FANS. OUTSIDE. WHERE PERMITTED BY LOCAL <br />REFERENCE ARCHITECTURAL/STRUCTURAL CODES, PVC-DWV PLASTIC SCHEDULE 40 <br />SHEETS FOR DETAILS. MAY BE USED IN LIEU OF CAST IRON. <br />ALL PHOTOLAB PLUMBING SHALL BE PVC. <br />7. CONTRACTOR SHALL INSTALL OWNER 26. WATER PIPING ABOVE GRADE SHALL BE <br />FURNISHED RTU CURB AND TEMPORARY TYPE "L" HARD DRAWN COPPER JOINED <br />COVER CURB PER ARCH DETAIL (IF WITH WROUGHT COPPER FITTINGS. MAKE <br />USED). RTU'S SHALL BE FURNISHED BY JOINTS USING LEAD-FREE SOLDER AND A <br />OWNER AND INSTALLED BY CONTRACTOR. NON -CORROSIVE, PASTE -TYPE FLUX. <br />CURB ADAPTOR (IF USED) SHALL BE MAKE PIPING CONNECTIONS TO A FIXTURE <br />D FURNISHED BY OWNER AND INSTALLED BY WITH CHROME -PLATED SEAMLESS BRASS <br />T CONTRACTOR. RTU SHALL BE SET ON TUBE. INSULATE HOT & COLD WATER <br />ROOF CURB. DO NOT SET RTU DIRECTLY PIPING WITH RIGID GLASS FIBER A <br />ON ROOF. COORDINATE RTU MINIMUM OF 1 /2" THICK WITH WHITE ALL - <br />INSTALLATION WITH WAL-MART SERVICE JACKET (VAPOR RETARDER). <br />CONSTRUCTION MANAGER AND AES AS <br />REQUIRED FOR RTU/AHU CURB ADAPTERS. 27. PROVIDE AUTOMATIC TRAP PRIMERS ON FLOOR <br />8. REPLACE FILTERS ON NEW RTU NO MORE DRAINS IF REQUIRED BY LOCAL PLUMBING <br />THAN ONE DAY PRIOR TO STARTING TEST CODES. <br />& BALANCE PROCEDURES. FILTERS SHALL 28. ALL FLOOR CLEANOUTS SHALL BE <br />BE 2" THICK EQUAL TO FARR 30/30. INSTALLED FLUSH WITH FLOOR FINISH <br />MATERIAL OR FLUSH WITH CONCRETE SLAB <br />9. LABEL RTU WITH 6" BLACK PERMANENT IF NO FLOOR FINISH MATERIAL IS <br />PAINT STENCIL AND LABEL SENSOR WITH CALLED OUT FOR ON ARCHITECTURAL <br />2" HIGH BLACK PERMANENT PAINT DRAWINGS. <br />STENCIL. NUMBER THE SENSOR TO <br />CORRESPOND WITH RTU IT CONTROLS. 29. LOCATE ALL FLOOR CLEAN -OUTS OUT OF <br />LOCATE LABEL FOR UNIT NEAR ITS TRAFFIC WAYS, WHILE MAINTAINING <br />DISCONNECT SO IT IS READABLE FROM ACCESSIBILITY. LOCATE PER <br />ROOF HATCH. DIMENSIONS IF SHOWN ON PLANS. <br />10. IF RTUS ARE INSTALLED BEFORE ROOFING 30. FLOOR CUTS SHALL BE STRAIGHT AND <br />IS COMPLETED, THE CONTRACTOR SHALL CLEAN, REPLACE REMOVED SLAB WITH <br />BE RESPONSIBLE FOR ANY DAMAGE WHICH CONCRETE FLUSH AND SMOOTH WITH <br />OCCURS DURING THE ROOFING PROCESS, ADJACENT FLOOR SLAB. REFERENCE <br />INCLUDING TAR ON COILS. ARCHITECTURAL SHEETS. COORDINATE <br />WITH GENERAL CONTRACTOR. <br />11. ROOFTOP UNIT CONDENSATE SHALL BE <br />ROUTED TO DRAIN WITH THE SLOPE OF THE 31. CAP ALL PIPING OPENINGS DURING <br />ROOF. CONSTRUCTION UNTIL FINAL CONNECTIONS <br />TO EQUIPMENT AND ACCESSORIES ARE <br />12. MECHANICAL FAILURE OF NEW ROOFTOP MADE. <br />UNITS PRIOR TO ACCEPTANCE BY OWNER, <br />SHALL BE REPAIRED OR REPLACED BY 32. CUT AND PATCH EXISTING CONCRETE <br />CONTRACTOR THROUGH WARRANTY FLOOR SLAB FOR INSTALLATION OF NEW <br />AGREEMENT WITH MANUFACTURER. UNDERGROUND PLUMBING PIPE. MATCH <br />EXISTING CONSTRUCTION. <br />13. IF APPLICABLE, COORDINATE ALL NEW GAS <br />PIPING AND ROOF EQUIPMENT WITH EXISTING 33. DO NOT INSTALL PIPING WITHIN COOLER <br />GAS PIPING, SKYLIGHTS, AND ROOF PANELS. INSTALL EXPOSED PIPING IN <br />EQUIPMENT. FIELD VERIFY EXISTING PREP AREAS A MINIMUM OF 1" FROM <br />CONDITIONS. PANEL WALL AND 6" ABOVE FINISHED <br />14. ROOFTOP UNITS BEING ADDED TO FLOOR TO ALLOW FOR CLEANING. USE <br />EXISTING ROOF STRUCTURE SHALL BE ONLY NON -CORROSIVE MATERIALS FOR <br />INSTALLED WHEN THE UNITS ARRIVE AT SPACERS AND ANCHORS. <br />THE JOB SITE. REFERENCE 34. PROVIDE ESCUTCHEON PLATES FOR <br />ARCHITECTURAL/STRUCTURAL SHEETS FOR PLUMBING PENETRATIONS THROUGH <br />DETAILS. GROCERY CEILINGS AND WALLS. <br />I 15. INSTALL VTR'S A MINIMUM OF 24" AND 35. PROVIDE AIR TIGHT SEAL AROUND PIPING <br />FLUES A MINIMUM OF 36" FROM ROOF PENETRATIONS THROUGH COOLER/FREEZER <br />EDGE AND/OR PARAPET WALLS. INSTALL WALLS AND CEILINGS. FINISH WITH <br />VTR'S, FLUES AND EXHAUST FANS A ESCUTCHEON PLATE. <br />MINIMUM OF 10 FT FROM OUTSIDE AIR <br />INTAKE OF ROOF TOP UNITS. INSTALL 36. PROVIDE HEAT TAPE AND INSULATION ON <br />EXHAUST FANS AND ROOF TOP UNITS A ALL WATER AND DRAIN PIPING EXPOSED <br />MINIMUM OF 10 FT FROM ROOF EDGE OR A TO FREEZING. <br />MINIMUM OF 60" FROM PARAPET WALLS <br />THAT ARE AT LEAST 42" HIGH. 37. INSTALL CONTINUOUS SEALANT JOINT AT <br />ALL EXTERIOR WALL PENETRATIONS. <br />16. COORDINATE LOCATION OF DUCTWORK AND <br />DIFFUSERS WITH LIGHT FIXTURES TO 38. AT CONTRACTOR'S OPTION, IN LIEU OF COPPER <br />PREVENT EXCESSIVE SHADOWING OF THE WATER PIPING, PEX OR AQUATHERM PIPING <br />SALES OR STOCK FLOORS. LIGHT FIXTURE MAY BE USED. REFER TO EQUIVALENT <br />LOCATIONS TAKE PRECEDENCE. FIELD NOMINAL PIPE SIZES SCHEDULE AND <br />VERIFY STRUCTURAL CONDITIONS BEFORE SPECIFICATIONS. <br />FABRICATION OF DUCTWORK. <br />39. PROVIDE SEISMIC BRACING BASED ON <br />APPROPRIATE SEISMIC ZONE REQUIREMENTS <br />pp 17. FLEXIBLE DUCT CONNECTIONS TO NEW OR PER SMACNA PUBLISHED SEISMIC DETAILS, <br />9 RELOCATED DIFFUSERS AND GRILLES ARE <br />PROHIBITED. INSPECT CONDITION OF LOCAL AND NATIONAL CODES. CONTRACTOR'S <br />I..::.- EXISTING DUCT AND REPLACE DAMAGED RESPONSIBILITY INCLUDES STRUCTURAL <br />II DUCT WITH EQUIVALENT TYPE OF DUCT AS ENGINEER'S CERTIFICATION ON DETAILS <br />REQUIRED. SUBMITTED FOR PERMITTING. <br />I� <br />18. DUCT SIZES SHOWN ON DRAWINGS ARE NET 40. BUILDING COMPONENTS ABANDONED BY THE <br />FREE AREA. CONTRACTOR'S OPTION, SCOPE OF WORK SHALL BE SECURED TO <br />ROUND DUCTWORK OF EQUIVALENT FREE PREVENT FALLING, LOOSENING, OR CREATING <br />AREA MAY BE USED IN LIEU OF DAMAGE OF ANY KIND IN THE FUTURE. <br />I RECTANGULAR. INCREASE RECTANGULAR <br />SHEET METAL SIZE AS REQUIRED FOR <br />LL LINER. REFER TO SPECIFICATIONS FOR <br />THE INSULATION THICKNESS. <br />_..._. 19. DUCT SUPPORT AND GRILLE DETAIL IS <br />-' APPLICABLE THROUGHOUT THE STORE. DO <br />NOT USE FASTENERS THAT PENETRATE ROOF <br />DECK. <br />20. TYPICAL BRANCH DUCT FITTING DETAIL IS <br />APPLICABLE THROUGHOUT THE STORE. <br />EAG1 <br />6" MOUNT AT <br />75 8'-0" AFF <br />ALL HVAC WORK ON THIS PROJECT IS TO BE <br />COMPLETED BY A WALMART APPROVED <br />CONTRACTOR. <br />EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />DRAWINGS AND MAY NOT REFLECT EXACT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />"AS -BUILT" CONDITIONS. CONTRACTOR SHALL FIELD SPECIFICATIONS IN THEIR RELATED FIELD. THE <br />VERIFY ALL EXISTING CONDITIONS PRIOR TO FAILURE TO ACQUAINT THEMSELF WITH THIS <br />SUBMITTING FINAL BIDS. CONTRACTOR SHALL KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY <br />CAREFULLY COORDINATE NEW WORK AND DEMOLITION OF PERFORMING THE WORK PROPERLY. NO <br />WITH ALL OTHER DISCIPLINES AND EXISTING ADDITIONAL COMPENSATION SHALL BE ALLOWED <br />CONDITIONS. BECAUSE OF CONDITIONS THAT OCCUR DUE <br />TO FAILURE TO FAMILIARIZE WORKERS WITH THIS <br />KNOWLEDGE. <br />ono <br />U <br />a <br />_V •� U <br />W <br />� <br />U <br />cd Q <br />Ld w Wwo <br />w <br />:1 1—oz <br />zm� z2- :,: <br />D N3 <br />LLJ W �cn�� a5,u,8� <br />as Qo0N=z<" <br />C) W�iJ *z0< -,w UOZ9H <br />O z a -X<0 X <br />LL- aN raor-2a� :) ,0 <br />J <br />tnU NSnwa3Xtnwp�QY <br />z L,�, . W, m �w <br />JO <br />p I 0�wgza��a <br />C.�d zp� OK�Uw UiY <br />QzcnJOfC*40 _noa2-"mz <br />J a¢=azw i,-L)">-v) ,._U <br />oz��om0L- L)MLLIzL) <br />0 m K w TKO w EwaLLJ ?<�m <br />NwCLZ -'=ow1 o000 0 <br />�Z)N0lncrDiaz)waawoam <br />z <br />Q <br />V) <br />z <br />O <br />U <br />z <br />0 <br />0 O <br />E- <br />a <br />� <br />�c <br />Q c <br />oa <br />0 O <br />Or <br />O <br />� <br />CD <br />� <br />a---� <br />O <br />� <br />z <br />LLJ <br />a� <br />O <br />e� <br />0 <br />0 <br />CQ <br />N <br />z <br />0 <br />ISSUE BLOCK <br />Q <br />ADD#2 <br />08/29/14 <br />Q <br />ADD#3 <br />07/11 /16 <br />CHECKED BY: <br />JJD <br />DRAWN BY: <br />DM <br />PROTO: <br />LBA <br />PROTO CYCLE: <br />051514 <br />DOCUMENT DATE: <br />120415 <br />•�0�,OAZ-VE4,g2''% <br />.tn . <br />No. 78 74 <br />S. EOF <br />ANAL <br />Jul 14, 2016 <br />PARTIAL <br />MECHANICAL <br />PLANS AND <br />DETAILS <br />NTS 08.13.01 <br />MECH2.1-5 <br />SHEET: <br />m 1 <br />