COMPRESSOR <br />HOUSE #1 - <br />A111]i' <br />TCH1 <br />SDP1 <br />CH1L <br />CONTRACTOR TO RELABEL H1 F <br />PANELS CH1F AND CH1A TO <br />MATCH THE LOADS BEING FED H1A <br />FROM THEM. REMOVE EXISTING <br />PANEL SCHEDULE AND POST <br />THE CORRECT PANEL <br />SCHDULE FOR EACH PANEL. <br />I <br />FEEDER SCHEDULE KEYNOTES <br />ALL CONDUIT AND CONDUCTOR SIZES ARE BASED ON EMT WITH 40% FILL, 750C RATED <br />TERMINATIONS AND TYPE THHN/THWN-2 INSULATION. FOR NON -EMT CONDUIT OR 16.145 CONNECT CIRCUIT(S) TO EXISTING BRANCH CIRCUITRY. <br />TERMINATIONS OR INSULATION TYPES RATED LESS THAN 75°C. MODIFY SIZES <br />ACCORDING TO NEC. MINIMUM WIRE SIZE AND PANELBOARD CIRCUIT ARE NOTED. <br />VERIFY SIZE, RATING AND CONDITION OF EXISTING BRANCH <br />® FEEDER OR GROUND SIZE CIRCUIT CONDUIT AND WIRE PRIOR TO USE TO ENSURE <br />22 (2)#12, (1)#12 G, 1/2" C THAT THEY MEET REQUIRED SIZE, AND ALL U.L. RATINGS <br />32 (2)#10, (1)#10 G, 1/2" C AND REPLACE AS REQUIRED. <br />43 (3)#8, (1)#10 G, 3/4" C 16.708 PROVIDE WIRING AND FINAL CONNECTIONS TO <br />63 (3)#6, (1}#10 G, 3/4" C RECEPTACLE. RECEPTACLE FURNISHED WITH <br />- -- - - - - REFRIGERATED CASE. <br />V053A (3#6, (1) #8 G, 3/4" C 16.711 POINT OF TRANSITION FROM EMT TO FLEX. PROVIDE <br />V063A (3)#4, (1)#6 G, 1" C CONDUIT AND BRANCH CIRCUITS FOR REFRIGERATED CASE <br />FANS, LIGHTS, ANTI -SWEAT HEATERS, AND ELECTRICAL <br />DEFROST (IF REQUIRED). TERMINATION TO REFRIGERATED <br />CASE ELECTRICAL CONNECTION POINT BY R.C. REFER TO <br />CASE CONNECTION WIRING DETAIL. <br />16.713 ROUTE EVAPORATOR COIL FAN (CF) AND/OR ELECTRIC <br />DEFROST (ED) CIRCUITS TO REFRIGERATION EQUIPMENT <br />DEFROST TERMINATION TROUGH. TERMINATIONS AT <br />EVAPORATOR COIL, CASE AND REFRIGERATION EQUIPMENT <br />BY RC. <br />16.944 REFRIGERATION ENERGY MANAGEMENT SYSTEM <br />CONTROLLER POWER: PROVIDE 120V CIRCUIT FOR VENDOR <br />FURNISHED REFRIGERATION CONTROLLER. WHEN <br />ENCLOSURE IS MOUNTED ON REFRIGERATED CASE, <br />CONNECT TO CASE 120V FAN CIRCUIT, UNLESS SHOWN <br />OTHERWISE. REFERENCE REFRIGERATION ENERGY <br />MANAGEMENT SHEETS FOR CONTROLLER WIRING. <br />16.978 PROVIDE WP GFI RECEPTACLE AS SHOWN AND MOUNT +44" <br />AFF ON BACK OF REFRIGERATED CASE. REFER TO CASE <br />MANUFACTURER SPECIFICATIONS FOR MOUNTING <br />INSTRUCTIONS. PROVIDE EMT CONDUIT FROM RECEPTACLE <br />TO RACEWAY PROVIDED WITH CASE. ROUTE CONDUIT FROM <br />RACEWAY WITH CASE ELECTRICAL CIRCUITS TO <br />STRUCTURE. <br />16.991 E.C. SHALL REMOVE EXISTING CONTACTOR IN RACK <br />CABINET AND CONNECT CIRCUITRY DIRECTLY TO CIRCUIT <br />OVERCURRENT PROTECTION DEVICE. REFRIGERATION <br />SYSTEM EVAPORATOR FAN/DEFROST CIRCUITS SHALL BE <br />CONTROLLED BY FACTORY INSTALLED CONTROLS IN NEW <br />CASES OR BY FIELD INSTALLED CONTROLS AT WALK-INS. IF <br />REQUIRED, E.C. SHALL INSTALL NEW VENDOR FURNISHED <br />OVERCURRENT PROTECTION DEVICE FOR REFRIGERATION <br />SYSTEM EVAPORATOR FAN/DEFROST CIRCUIT. PROVIDE A <br />NEW NEMA 1 ENCLOSURE FOR FAN/DEFROST CIRCUIT <br />OVERCURRENT PROTECTION DEVICE, IF NEEDED. MOUNT <br />NEMA 1 ENCLOSURE AS CLOSE AS POSSIBLE TO EXISTING <br />RACK CABINET. REFER TO REFRIGERATION LEGEND(S). <br />2 3 4 <br />I I I <br />16.145 CH1F-11 CH1F-17--1 <br />i CH1F-14 r 16.145 C H 1 F-6 <br />o 16.145 CH1A-31,33,35,37� -, .145 j 16CH1A-14,16,18,20 � <br />�, 16.145 �6.991 16.713 63 (ED) �--\\I 16.991 �16.713 V063A (ED) 1 <br />CH1F-23r - -------------- ------------, E= --------------- 1=1 --------------- =I------------- <br />i <br />16.145ED)- i A9c A9b--J LS3C' Aga Al2d Al2c Al2b L Al2a <br />16.991 1 6 <br />() -----, Boa I Q A10a , S3C ; A10b A10c A11 a ; S3C ; A11 b A11 c <br />: S3C , i 0 --- 0 0 0 --- 0 0 <br />Lcn, CH2F-15----+---------------------------� L-----------------------� <br />16.145 i 16.991 16.713 V053A (ED) Jjll 16.991 16.713 V053A (ED) / 16.145 CW F-8 <br />o m 16.145 CH1F-13.Y �Ij CH1F-15 <br />i i 16.145 CH1A-2,4,65 -JI 16.145 CH1A-8,10,12 - <br />L�,i m i 16.145 CH1L-13J CH1F-3 CH1F 9 <br />c�'i 16.145 CH1F-2 - 66.145 CH1A-3,5,7,9 16.145 CH1A-23,25,27,29 <br />�L--� <br />� 16.991 16.713 63 (ED) �� � 16.991 16.713 V063A (ED) <br />I----------------------------i------------------------------------------I <br />CH1 F-25 i i i i A5c A5b--J LS3C I A5a CA8d A8c ASbILA8a <br />43 (ED) i i i i 16.145 O <br />U) <br />16.991 i i i A6a LS3C, A6b A6c Ala LS3C, __-i Alb A7c <br />16.711 i 16.991 16.713 V053A (ED) � -;II 16.991 16.713 V053A (ED)� / <br />CH1F-5 I - - - - CH1F-7 16.145 CH1F-4 S- <br />i m i m i 16.145 CH1A-11,13,15S--JI 16.145 CH1A-17,19,21 2 <br />i CH1 F-21 f <br />16.145 CH1L-5 �- CH1F-19 �1 1 RE1.1 <br />rUi' _i 16.145 CH1A-22,24,26,28`r �� 16.145 CH1A-30,32,34 <br />CH2F-13 -- 16.145 CW F-10 - 16.711 <br />16.991 16.713 63 (ED) �� 16.991 16.713 V063A (ED) l (TYP) <br />-------------------------i �-------------�-------------�-------------� <br />U B1c B1b - LS3C; B1a 62d B2c B2b 62a <br />i <br />J 16.708 <br />CHO(NP) <br />16.145 <br />Ap <br />CH2F-30 16.145 16.145 CH1F-12` -� <br />G� <br />P� <br />CH 1 F-37 16.145 <br />(ED) 22 16.145 16.991 <br />CH1A-1 16.145 I <br />CH1F-1 16.145 <br />' U' (ED) 32 16.145 16.991 - - - <br />Q <br />I <br />I <br />I <br />C2a <br />r-------------- <br />i <br />16.145 U C2b <br />CH2F-3 cf); C2d <br />I <br />16.145 <br />2 CH2F-11 <br />ASR <br />E= --------------� <br />16.944 <br />C6b LS3C ; C6a (TYP) <br />CH2F-7 <br />CH2F-32 16.978 -� 16.145 <br />16.145 Cob LS3C ; C4a CH2F-33 <br />a <br />C,): C19 <br />ELECTRICAL GENERAL NOTES <br />ELECTRICAL SYMBOLS LEGEND <br />(NOT ALL SYMBOLS ARE NECESSARILY USED ON THE DRAWINGS.) <br />CX-02 27 20 <br />CX-W-07.26.20 <br />SYMBOL <br />DESCRIPTION <br />1. <br />FURNISH AND INSTALL ALL MATERIALS FOR A COMPLETE <br />19. <br />PROVIDE AND INSTALL A CUSTOM, DIGITALLY PRINTED AND <br />INSTALLATION IN ALL RESPECTS READY FOR INTENDED USE AND <br />HIGH -DURABILITY LAMINATED LABEL, RATED FOR OUTDOOR <br />TRACE <br />NEUTR4� <br />CIRCUIT, CONCEALED IN WALLS OR <br />IN STRICT ACCORDANCE WITH NEC, NESC, STATE AND LOCAL <br />APPLICATIONS. ON ALL SWITCHBOARDS AND PANELBOARDS. <br />GROUND- H°TS <br />CEILING <br />CODES AND MANUFACTURER'S RECOMMENDATIONS. <br />LETTERING SHALL BE BLACK, MINIMUM OF 1/4" HIGH, ON A <br />COORDINATE BETWEEN EXISTING AND NEW CONSTRUCTION. <br />YELLOW BACKGROUND AND SHALL INCLUDE THE FOLLOWING: <br />CONTRACTOR SHALL PAY FOR ALL NECESSARY FEES AND <br />PERMITS. <br />LINE 1: FEEDER POWER SUPPLY FOR <br />CIRCUIT, EXPOSED <br />LINE 2: PANELBOARD " " ORIGINATES <br />2. <br />KEEP PENETRATIONS THROUGH COOLER AND FREEZER BOXES <br />LINE 3: AT PANELBOARD <br />CIRCUIT, IN/UNDER FLOOR/GROUND <br />TO A MINIMUM. ROUTE ALL CONDUITS SERVING FREEZERS AND <br />Ij <br />CONSTRUCTION <br />COOLERS ON THE INSIDE OF THE BOX, UNLESS NOTED <br />20, <br />PROVIDE AND INSTALL A CUSTOM DIGITALLY PRINTED AND HIGH - <br />EXISTING CIRCUIT, CONCEALED IN <br />OTHERWISE. <br />DURABILITY LAMINATED LABEL, RATED FOR OUTDOOR <br />WALLS OR CEILING <br />APPLICATIONS, ON ALL TRANSFORMERS. LETTERING SHALL BE <br />EXISTING CIRCUIT, EXPOSED <br />3. <br />PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: <br />A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE <br />BLACK, MINIMUM OF 1/4" HIGH, ON A YELLOW BACKGROUND AND <br />SHALL INCLUDE THE FOLLOWING: <br />STOPPING. <br />tf <br />EXISTING CIRCUIT, IN/UNDER <br />B. FREEZER/COOLER BOXES: SEAL WITH SILICONE SEALANT. <br />LINE 1: FEEDER POWER SUPPLY FOR <br />--- fl}- <br />FLODR/GROUND CONSTRUCTION <br />C. EXTERIOR: REFER TO FIXTURE PLANS AND SPECIFICATIONS <br />LINE 2: TRANSFORMER " " ORIGINATES <br />FOR SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED <br />LINE 3: IN "SWITCHBOARD OR PANELBOARD <br />SURFACE MOUNTED PANELBOARD <br />DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY <br />LINE 4: LOCATED IN " <br />PENETRATIONS. <br />= <br />FLUSH MOUNTED PANELBOARD <br />21. <br />WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM <br />4. <br />WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT <br />FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED <br />17 <br />VOICE / DATA BOX <br />IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING <br />OTHERWISE ON PLANS. COORDINATE THE STANDARD <br />DIAGRAMS. <br />MOUNTING HEIGHTS WITH MASONRY: <br />EQUIPMENT CONNECTION POINT <br />A. SWITCHES:+44" <br />o ° <br />(PROVIDED WITH EQUIPMENT) <br />5. <br />BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG <br />B. RECEPTACLES +20" <br />UNLESS NOTED OTHERWISE IN SCHEDULES. THE FINAL <br />C. VOICE/DATA +20" <br />LDP <br />REFRIGERANT LEAK DETECTION PANEL <br />CONNECTION (15-FT MAXIMUM) SHALL BE #10AWG WHERE 20A <br />BRANCH CIRCUITS HAVE #8AWG AND LARGER WIRE SPECIFIED. <br />22. <br />DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE: <br />INSTALL ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND <br />0 <br />LIGHT FIXTURE <br />6. <br />WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND <br />PHONE CABLING 3 WEEKS PRIOR TO CONTRACT SUBSTANTIAL <br />DERATE CURRENT CARRYING CONDUCTORS PER NEC. <br />COMPLETION DATE. <br />LIGHT FIXTURE, NIGHT LIGHT (PROVIDE <br />CONSTANT HOT TO FIXTURE) <br />7. <br />CONDUITS EXTENDING BEYOND EXTERIOR WALL: STUB OUT 2'-0" <br />23. <br />PROVIDE NEUTRAL CONDUCTOR TO ALL WALL LIGHT SWITCH <br />OCCUPANCY SENSOR (CEILING <br />BELOW GRADE TO 5'-0" BEYOND EXTERIOR WALLS UNLESS <br />LOCATIONS. IF NEUTRAL TERMINATION IS NOT REQUIRED, CAP <br />MOUNTED / WALL MOUNTED) <br />NOTED OTHERWISE. COORDINATE LOCATION AND PROVIDE <br />CONDUCTOR AND TAG AS "NEUTRAL FOR FUTURE USE". <br />CONNECTION TO SITE CONDUITS. <br />SWITCH, SINGLE POLE <br />24. <br />EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES <br />8. <br />PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR <br />DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM <br />$3 <br />SWITCH, 3-WAY <br />(SIZE PER NEC) IN PVC TYPE CONDUIT, POWER CIRCUITS, <br />AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT <br />ISOLATED GROUND CIRCUITS. OR AS SHOWN ON PLANS. <br />SYSTEMS REMAIN OPERATIONAL AT ALL TIMES. <br />CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT <br />$4 <br />SWITCH, 4-WAY <br />COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT <br />25. <br />DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE <br />GROUNDING CONDUCTOR. <br />SURFACE MOUNTED UNLESS NOTED OTHERWISE. REFER TO <br />ARCHITECTURAL DOCUMENTS FOR CONDUIT INSTALLATION AND <br />RECEPTACLE, DUPLEX <br />9. <br />SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE <br />SEALING REQUIREMENTS. <br />SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE <br />RECEPTACLE, SIMPLEX <br />ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE <br />26. <br />ARRANGE ALL WORK THAT REQUIRES POWER INTERRUPTIONS <br />ELECTRICAL SYSTEM INSTALLATIONS. <br />TO THE STORE TO BE ACCOMPLISHED AFTER NORMAL STORE <br />O <br />JUNCTION BOX (WALL MOUNTED / <br />BUSINESS HOURS. NOTIFY THE STORE MANAGER AND THE <br />CEILING MOUNTED) <br />10. <br />VERIFY ALL WALL FINISH THICKNESSES BEFORE INSTALLING <br />OWNER'S MECHANICAL CONSTRUCTION MANAGER A MINIMUM <br />BOXES. PROVIDE EXTENDED BOXES OR BOX EXTENDERS <br />OF 48 HOURS IN ADVANCE OF ALL STORE POWER <br />❑, <br />NON -FUSED DISCONNECT <br />WHERE REQUIRED. <br />INTERRUPTIONS. STORE MANAGER MUST ALLOW FOR <br />POWERING DOWN OF COMPUTER SYSTEMS, MOVING AFFECTED <br />Zh <br />FUSED DISCONNECT <br />11. <br />VERIFY THAT THE PANELBOARDS USED HAS THE SPACE AND <br />PRODUCT, MODIFICATION OF STORE AFTER-HOURS WORK <br />AMPACITY TO DO SO PRIOR TO ROUGH -IN. <br />SCHEDULES, COORDINATION WITH OTHER TRADES, AND OTHER <br />RCC iPRO S3C KE2 <br />REFRIGERATION BUILDING AUTOMATION <br />CONTROLLER <br />12. <br />TRACE ALL ELECTRICAL CIRCUITS FOR ALL EXISTING <br />CRITICAL SCHEDULING CONCERNS. PROVIDE TEMPORARY <br />POWER AS REQUIRED. INSTALLATION OF NEW EQUIPMENT <br />ELECTRICAL PANELBOARDS AFFECTED BY THE PROJECT AND <br />SHALL BE COMPLETED AND THE POWER SYSTEM TESTED AND <br />REFRIGERATED CASE WIRING <br />IDENTIFY LOADS ON EACH CIRCUIT. PROVIDE A NEW COMPLETE <br />RE -ENERGIZED PRIOR TO START OF BUSINESS THE FOLLOWING <br />TYPEWRITTEN PANELBOARD IDENTIFICATION SCHEDULE, PER <br />MORNING NO LATER THAN A TIME ESTABLISHED BY THE STORE <br />NOTES <br />NEC 408.4, FOR ALL AFFECTED PANELBOARDS. <br />AND THE OWNER'S MECHANICAL CONSTRUCTION <br />MMANAGER <br />ANAGER <br />Cx-02.27.20 <br />13. <br />VERIFY THAT ALL PANELBOARDS HAVE CIRCUIT BREAKER <br />1. PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE FANS, <br />KNOCKOUTS PROPERLY COVERED AND THAT ALL TRIM IS IN <br />27. <br />CONTRACTOR SHALL PAINT ALL NEW CONDUIT EXPOSED TO <br />LIGHTS, HEATERS, CONTROLLERS, ELECTRIC DEFROST, AND <br />GOOD CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. <br />SALES FLOOR. MATCH CEILING OR ADJACENT WALL COLOR <br />CASE RECEPTACLES UNLESS NOTED OTHERWISE. PROVIDE <br />(WHERE APPLICABLE). CONDUIT SHALL BE PAINTED PRIOR TO <br />ADEQUATE CONDUCTOR LENGTH TO ALLOW TERMINATION. <br />14. <br />DEMOLITION: COORDINATE THE EXTENT OF ELECTRICAL <br />INSTALLATION. <br />NEATLY BUNDLE CIRCUITS AND CLEARLY TAG AND LABEL EACH <br />DEMOLITION WITH FIXTURE AND DEMOLITION PLANS. REMOVE <br />CIRCUIT WITH BRANCH CIRCUIT DESIGNATION AND <br />ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, RELAYS, <br />28. <br />PROVIDE NEW MATERIALS FOR ALL WORK SHOWN ON PLANS <br />REFRIGERATION SYSTEM NUMBER FOR FINAL TERMINATION AT <br />TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL NOT BE <br />UNLESS NOTED OTHERWISE. EXISTING MATERIALS THAT MEET <br />CASE. REF CASE CONNECTION WIRING DETAIL. <br />REUSED. PROVIDE A COMPLETE DEMOLITION OF ALL EQUIPMENT <br />ALL REQUIREMENTS OF THEIR NEW USE, ARE IN GOOD <br />UNLESS EQUIPMENT IS SPECIFICALLY NOTED TO BE REUSED. <br />CONDITION, AND MEET ALL U.L. RATINGS MAY BE REUSED WITH <br />2. REFRIGERATED CASE WIRING COMPARTMENT REPRESENTED <br />DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE <br />THE SPECIFIC APPROVAL OF THE OWNER'S MECHANICAL <br />ON DRAWING BY RECTANGULAR BOX. <br />NOTED. REMOVE CONDUITS AND WIRES ALL THE WAY BACK TO <br />CONSTRUCTION MANAGER. <br />ORIGINATING PANELBOARDS. REMOVE SWITCHES AND/OR <br />3. PROVIDE WIRE AND CONDUIT FOR SLAVE WIRING BETWEEN <br />DEVICES SERVING DEMOLISHED EQUIPMENT AND TURN OVER <br />29. <br />ALL PANELBOARDS SHOWN ON PLAN ARE EXISTING TO REMAIN, <br />CASES IN WIREWAY. <br />TO OWNER'S MECHANICAL CONSTRUCTION MANAGER. <br />UNLESS NOTED OTHERWISE. <br />DEMOLITION SHALL NOT AFFECT ACTIVE CIRCUITS. ALL CIRCUIT <br />4. ROUTE CASE ELECTRICAL CIRCUITS WITH REFRIGERATION <br />BREAKERS SERVING BRANCH CIRCUITS TO BE REMOVED SHALL <br />30. <br />UPON COMPLETION OF ELECTRICAL INSTALLATION AND PRIOR <br />PIPING FROM FIRST CASE IN EACH SYSTEM TO STRUCTURE. <br />ALSO BE REMOVED. REMOVE CIRCUIT BREAKER AND REPLACE <br />TO ENERGIZING CIRCUIT: <br />ROUTE ELECTRICAL CIRCUITS UNDERSLAB WHERE <br />WITH FILLER PLATE. PROVIDE A COMPLETE TYPEWRITTEN <br />A. INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. <br />REFRIGERATION PIPING IS ROUTED UNDERSLAB. <br />PANELBOARD, LABELING NEWLY DEMOLISHED CIRCUIT(S) WITH <br />B. PERFORM CONTINUITY TEST. <br />"SPACE". REFER TO SELECTIVE SITE DEMOLITION SPECIFICATION <br />C. VERIFY PROPER PHASING CONNECTION TO ALL THREE <br />5. ALL UNDERSLAB CONDUITS SHALL BE 3/4" MIN. <br />FOR DISPOSAL OF DEMOLISHED FLUORESCENT LIGHT FIXTURES. <br />PHASE MOTOR LOADS. <br />6. CONNECT ELECTRICAL DEFROST, ON GROUPS OF THREE OR <br />15. <br />NEW CIRCUITS: ROUTE NEW ELECTRICAL CIRCUITS FOR THIS <br />31. <br />NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE <br />MORE REFRIGERATED CASES, IN SUCH A MANNER AS TO <br />PROJECT TO PANELBOARD AS INDICATED ON DRAWINGS. <br />ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS UNLESS <br />CREATE A THREE-PHASE HEATER CIRCUIT. HEATER LOADS <br />ROUTING CIRCUITRY ACROSS ROOF OR EXTERIOR WALLS IS NOT <br />NOTED OTHERWISE. <br />SHALL BE BALANCED AMONG PHASES AS EVENLY AS POSSIBLE. <br />ALLOWED. NEW FEEDER AND BRANCH CIRCUIT CONDUITS <br />REF CASE DEFROST WIRING DETAIL. <br />SHALL BE ROUTED WITHIN THE BAR JOIST SPACE. OTHER THAN <br />32. <br />ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. <br />CONNECTION TO EQUIPMENT OR DISPLAYS, ELECTRICAL <br />7. WHEN NEW CASES ARE PROVIDED WITH A FACTORY INSTALLED <br />CONDUITS WILL NOT BE PERMITTED BELOW BOTTOM CHORD OF <br />33. <br />NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN <br />TERMINAL STRIP AND JUMPERS FOR CONNECTION TO A SINGLE <br />BAR JOIST. ROUTING CIRCUITRY DIRECTLY UNDER LIGHT <br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL <br />CIRCUIT FOR 120V CASE LOADS, REMOVE FACTORY INSTALLED <br />FIXTURES IS NOT ALLOWED. <br />MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT <br />JUMPERS AS REQUIRED TO UTILIZE EXISTING SEPARATE 120V <br />PROTECTIVE DEVICES. <br />FAN/LIGHT/ANTI-SWEAT CIRCUITS AS INDICATED ON PLANS <br />16. <br />EXISTING CIRCUITS: PROVIDE LABOR AND MATERIALS TO <br />AND/OR PANELBOARD SCHEDULES. ANY EXISTING ANTI -SWEAT <br />REWORK CIRCUITRY AS REQUIRED TO MAINTAIN OPERATION <br />34. <br />BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM AWG <br />CONTROL (SWEATMISER) SHALL BE BY-PASSED. CASES <br />WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br />UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A <br />UTILIZING ELECTRICAL DEFROST WILL BE PROVIDED WITH <br />EXISTING TELEPHONE, DATA, SECURITY, OR ELECTRICAL <br />BRANCH CIRCUITS HAVE AND LARGER WIRE SPECIFIED, AWG <br />SEPARATE 208V TERMINATIONS AT THE TERMINAL STRIP FOR <br />CIRCUITS FEEDING EXISTING EQUIPMENT, DEVICES, OR LIGHTING <br />WIRE SHALL BE USED FOR THE FINAL CONNECTION (15-FT <br />CONNECTION TO THE 208V ELECTRIC DEFROST CIRCUIT. MAKE <br />TO REMAIN BUT NOT SHOWN ON DRAWINGS. <br />MAXIMUM). <br />FINAL TERMINATIONS OF 120V AND 208V POWER CIRCUIT(S) AT <br />CASE TERMINAL STRIP. REFER TO CASE CONNECTION <br />17. <br />UNDERGROUND SERVICES: IF DEMOLITION OR NEW <br />35. <br />PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH <br />SCHEMATIC ON REFRIGERATION SHEETS. <br />CONSTRUCTION DISRUPTS EXISTING UNDERGROUND SERVICES <br />CIRCUITS SHARING COMMON NEUTRAL FOR SIMULTANEOUS <br />(ELECTRICAL, TELEPHONE, PARKING LOT LIGHTING CIRCUITRY, <br />TRIP PER NEC REQUIREMENTS. <br />8. PROVIDE A SEPARATE NEUTRAL FOR EACH NEW BRANCH <br />ETC.) PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO <br />CIRCUIT SERVING REFRIGERATED CASES. <br />REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES <br />36. <br />FOR ELECTRICAL EQUIPMENT AS REQUIRED BY LOCAL CODES. <br />TO MAINTAIN THEIR PROPER OPERATION. <br />9. PROVIDE CIRCUIT BREAKER LOCKING DEVICE (LOCK -OFF FOR <br />37. <br />WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br />MAINTENANCE) ON NEW AND/OR EXISTING CIRCUIT BREAKERS <br />18. <br />PROVIDE AND INSTALL A CUSTOM, DIGITALLY PRINTED AND <br />EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, <br />SERVING REFRIGERATED CASES. <br />HIGH -DURABILITY LAMINATED LABEL, RATED FOR OUTDOOR <br />DEVICES, OR LIGHTING TO REMAIN. BUT NOT SHOWN ON <br />APPLICATIONS, ON ALL SERVICE EQUIPMENT. LETTERING SHALL <br />DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK <br />BE BLACK, MINIMUM OF 1/4" HIGH, ON A YELLOW BACKGROUND <br />CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION. <br />AND SHALL INCLUDE THE FOLLOWING: <br />LABEL 1: <br />LINE 1: VOLTAGE AND HERTZ <br />LINE 2: SERVICE EQUIPMENT BUS RATING <br />w >v 0 <br />> >ui o L0 > <br />LL <br />U) <br />O zu W, azc9ZQ <br />W ZH.O�Z�� <br />W <br />o F Ozw~�wazz <br />Of <br />aF =cnLLw�opo�wS <br />O <br />a �~ 0 a wwaZa O�ii, <br />Ww <br />LL <br />�m o=>���a <br />Z <br />O <br />aLL�O'w�C7~Ow�O=p <br />W N z "I F <br />- w D O z z Z <br />owvia�cew¢¢awvo0a <br />Zco-C) LL ) 0,<Oao <br />J <br />� aw2zW�U�wwww00E�' <br />Ewa zr�OF a0wamPw. <br />= nw OamC�WxwUWwn=. <br />U) <br />F ON 000M0 W L-K0�aH', <br />Z <br />Q <br />CDo <br />0o <br />w � <br />w <br />(.0E- <br />r- <br />�� [2 <br />Lu <br />. ° <br />mcV <br />W <br />W <br />U)10� <br />wcOX <br />Z <br />CV wO <br />Lnp00 <br />Q Lu <br />>tna <br />Z <br />W <br />oZc- <br />oYm <br />Z <br />CD CD}N <br />F <br />Z Z <br />W C� <br />oQ <br />Qxo <br />o <br />o <br />ELF <br />M~af <br />Z <br />Z <br />i LU <br />wZo <br />w <br />Z <br />`�'oa- <br />LLJ <br />H <br />Lu J <br />Z <br />Cy w <br />J <br />- <br />lC> M <br />mLL <br />= <br />J <br />el� <br />O <br />LLJ <br />E <br />U <br />I- <br />ISSUE BLOCK <br />CHECKED BY: JPUJDS <br />DRAWN BY: RR <br />DOCUMENT DATE: 06/30/23 <br />LINES 3&4: SHORT-CIRCUIT CURRENT RATING (SCCR) OF <br />THIS ITEM HAS BEEN <br />SERVICE EQUIPMENT <br />ELECTRONICALLY SIGNED <br />AND SEALED BY JOHN D. <br />LABEL 2: <br />STOWELL ON THE DATE <br />LINES 1&2: MAXIMUM AVAILABLE FAULT CURRENT <br />LISTED BELOW USING A <br />LINES 3&4: DATE CALCULATED <br />DIGITAL SIGNATURE. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />DECOMMISSIONING NOTE <br />SEALED AND THE <br />SIGNATURE MUST BE <br />Cx-05.20.18 <br />VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />DISPOSAL OF ALL DECOMMISSIONED EQUIPMENT, NOT APPORTIONED TO OWNER'S DESIGNATED SALVAGE VENDOR, SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR IN ACCORDANCE WITH SECTION 1351 AND 1500 OF THE SPECIFICATIONS, LOCAL CODES, AND ANY <br />GOVERNMENTAL REGULATIONS. THE CONTRACTOR SHALL COORDINATE THE PICK-UP DATE WITH THE DESIGNATED SALVAGE VENDOR. <br />PREPARE AND LOAD THE DESIGNATED SALVAGE ITEMS, KEEPING THEM INTACT AND IN ACCORDANCE WITH SECTION 1351 AND 1500 OF THE <br />SPECIFICATIONS, LOCAL CODES, AND ANY GOVERNMENTAL REGULATIONS. ITEMS TO BE SALVAGED BY OWNER'S DESIGNATED SALVAGE <br />VENDOR SHALL BE LIMITED TO: VARIABLE FREQUENCY DRIVES, CONDENSING UNITS, CONDENSERS, EVAPORATORS, COPPER PIPING, ROOF <br />TOP UNITS, AIR HANDLING UNITS, AND COMPRESSOR HOUSES. <br />ELECTRICAL ABBREVIATIONS <br />(NOT ALL ABBREVIATIONS ARE NECESSARILY USED ON THE DRAWINGS.) <br />U-04.10 12 <br />H, HTR <br />ANTISWEAT HEATER <br />GFEP <br />GROUND FAULT EQUIPMENT <br />RCPT <br />RECEPTACLE <br />JOHN D. STOWELL <br />CIF <br />COIL FAN <br />PROTECTION <br />REF <br />REFER <br />LICENSE # 91727 <br />C <br />CONDUIT <br />G, GND <br />GROUND <br />REFRIG <br />REFRIGERATION <br />eeeeva��e:rat <br />CNTRLR <br />CONTROLLER <br />H, HTR <br />HEATER <br />S/M <br />SWEATMISER <br />a`.,e p. Sro <br />CLR <br />COOLER <br />IG <br />ISOLATED GROUND <br />TEMP <br />TEMPERATURE <br /><` �N ........ <br />E N 361 �% <br />DR <br />DOOR <br />L, LTS <br />LIGHTS <br />XFMR <br />TRANSFORMER <br />;�Ci •'�� <br />ED <br />ELECTRIC DEFROST HEATER <br />M.C.B. <br />MAIN CIRCUIT BREAKER <br />TYP <br />TYPICAL <br />No. 91 727 0 <br />EF <br />EXHAUST FAN <br />M.L.O. <br />MAIN LUG ONLY <br />UH <br />UNIT HEATER <br />v <br />e # <br />ETR <br />EXISTING TO REMAIN <br />NTS <br />NOT TO SCALE <br />UNO <br />UNLESS NOTED OTHERWISE <br />EVAP <br />EVAPORATOR FAN COIL <br />OS <br />OCCUPANCY SENSOR <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />: 0 x' <br />F <br />FANS <br />PNLBD <br />PANELBOARD <br />W <br />WIRE <br />= -)�) ' STATE OF wZ <br />FZR <br />FREEZER <br />PART <br />PARTIAL <br />WH <br />WATER HEATER <br />GFCI <br />GROUND FAULT CIRCUIT <br />INTERRUPTER <br />PH <br />P.O.S. <br />PHASE <br />POINT OF SALE <br />WP <br />WR <br />WEATHERPROOF COVER <br />WEATHER RESISTANT <br />�S' •.��•� �® <br />��°° S/O�'• ��`i <br />�IfBF?9i9'61,� <br />06/30/2023 <br />FRONT <br />REFRIGERATION <br />ELECTRICAL <br />PLAN <br />VFRONT REFRIGERATION ELECTRICAL PLAN <br />1 1 /8" = V-0" <br />EXISTING CONDITIONS WERE TAKEN FROM <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR <br />SHALL CAREFULLY COORDINATE NEW WORK AND <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND <br />EXISTING CONDITIONS. <br />4CH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />DECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />D ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />OT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />�E WORK PROPERLY. NO ADDITIONAL <br />OMPENSATION SHALL BE ALLOWED BECAUSE OF <br />ONDITIONS THAT OCCUR DUE TO FAILURE TO <br />NMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />SHEET: <br />RE1 <br />