x <br />w <br />CONTINUE OF SECTION 07 51 00 <br />3.4. ROOF MEMBRANE INSTALLATION: <br />3.4.1 SHINGLING OF PLIES: EXCEPT AS OTHERWISE INDICATED, INSTALL <br />MEMBRANE WITH PLY SHEETS SHINGLED UNIFORMLY TO ACHIEVE REQUIRED <br />NUMBER OF PLIES OF MEMBRANE THROUGHOUT. SHINGLE IN PROPER <br />DIRECTION TO SHED WATER ON EACH AREA OF ROOFING. <br />3.4.2 BROOM IN EACH PLY AS DIRECTED BY MANUFACTURER. USE BROOM <br />APPROVED BY MANUFACTURER. <br />3.4.3 CANT STRIPS/TAPERED EDGE STRIPS: EXCEPT AS OTHERWISE SHOWN, INSTALL <br />PREFORMED <br />45 DEG. INSULATION CANT STRIPS AT JUNCTURES OF BUR MEMBRANE WITH <br />VERTICAL SURFACE. PROVIDE PREFORMED TAPERED EDGE STRIPS AT AREAS <br />SHOWN ON DRAWINGS AS NEEDED TO DIVERT WATER. <br />3.4.4 INTER -PLY SHEETS: PROVIDE THE NUMBER AND TYPE(S) OF PLY SHEETS <br />(FELTS) INDICATED, LAPPED (SHINGLED) AMOUNT AS REQUIRED TO FORM A <br />CONTINUOUS, UNIFORM MEMBRANE WITH BITUMEN MOPPINGS BETWEEN <br />SHEETS SO THAT PLY SHEET DOES NOT TOUCH PLY SHEET. EXTEND <br />BUILT-UP ROOFING MEMBRANE TO 2" (NOMINAL) ABOVE TOP EDGE OF CANT <br />STRIP AND TERMINATE. <br />3.4.5 ALL EDGE METAL SHALL BE INSTALLED BEFORE INSTALLATION OF CAP <br />SHEET. BACKWATER LAPS ARE NOT ALLOWED. <br />3.4.6 INSTALL CAP SHEET IN STRICT COMPLIANCE WITH MANUFACTURER'S <br />INSTRUCTIONS. <br />3.4.6.1 AT HEAD LAPS, CUT TEE JOINTS 45 DEGREES. ROUND EXPOSED <br />CORNERS. <br />3.4.6.2 PROVIDE ADDITIONAL LAYER OF CAP SHEET AT DOORS OF <br />MECHANICAL EQUIPMENT ROOMS AND AT ROOF HATCHES. <br />3.4.7 MEMBRANE FLASHINGS: <br />3.4.7.1 PROVIDE 2 PLY BASE FLASHING AT ALL ANGLE CHANGES <br />CONSITING OF 1 PLY OF ASTM D-2178 TYPE IV GLASS FELT SET IN <br />HOT MOPPING OF TYPE IV ASPHALT FOLLOWED BY 1 PLY OF SBS CAP <br />SHEET (SAME MATERIAL AS ROOFING CAP SHEET) SET IN A CONTINUOUS <br />TROWELING OF MATRIX 201. SIMILAR TO U.S. INTEC DETAIL SBS5. <br />CORNERS ARE TO BE FLASHED PER DETAILS SBS 11 AND SBS 12 <br />(FORMERLY FLEX3). <br />3.4.7.2 AT HORIZONTAL METAL FLANGES, I.E. GRAVEL GUARD MB, <br />ELECTRICAL AND MECHANICAL METAL FLANGES, METAL IS TO BE PRIMED <br />WITH A D-41 PRIMER AND SET IN A FULL BED OF MATRX 201. METAL <br />FLANGES ARE TO BE FLASHED THE SAME DAY THEY ARE INSTALLED WITH <br />1 PLY OF INTEC/FLEX SMOOTH, 6" WIDER THAN <br />THE FLANGE BEING FLASHED, SET IN A CONTINUOUS TROWELING OF MATRIX <br />201. <br />3.4.8 AT ALL LOCATIONS WHERE "BLEED -OUT' OF ASPHALT IS PRESENT, APPLY <br />MINERAL GRANULES WHICH MATCH THE GRANULES OF THE CAP SHEET TO <br />ACHIEVE 100% HIDING OF THE ASPHALT. APPLY GRANULES WHILE ASPHALT IS <br />WARM ENOUGH TO ALLOW SOLID IMBEDMENT. <br />3.4.9 ALLOW FOR EXPANSION OF RUNNING METAL FLASHING AND EDGE TRIM <br />WHICH ADJOINS ROOFING. <br />3.4.10 COUNTER FLASHINGS: COUNTER FLASHINGS, CAP FLASHINGS, EXPANSION <br />JOINTS AND SIMILAR WORK SHALL BE COORDINATED WITH BUILT-UP ROOFING <br />WORK. <br />3.4.11 SEAMS: RIVET AND SOLDER ALL JOINTS IN GUTTERS. OTHER JOINTS <br />SHALL BE FORMED FOR BACK SPLICE PLATES AS REQUIRED. SEAL WITH <br />URETHANE SEALANT. <br />1.1. PROTECTION OF ROOFING: <br />3.5.1 UPON COMPLETION OF ROOFING WORK (INCLUDING ASSOCIATED WORK) <br />INSTALLER SHALL ADVISE CONTRACTOR OF RECOMMENDED PROCEDURES FOR <br />SURVEILLANCE AND PROTECTION OF <br />ROOFING DURING REMAINDER OF CONSTRUCTION PERIOD. <br />3.5.2 INSTALLER SHALL REPAIR OR REPLACE (AS REQUIRED) DETERIORATED OR <br />DEFECTIVE WORK FOUND AT TIME OF FINAL INSPECTION. INSTALLER SHALL BE <br />T R OFING WHICH <br />ENGAGED BY CONTRACTOR TO REPAIR DAMAGES 0 0 <br />OCCURRED SUBSEQUENT TO ROOFING INSTALLATION AND PRIOR TO FINAL <br />INSPECTION. REPAIR OR REPLACE THE ROOFING AND ASSOCIATED WORK TO A <br />CONDITION FREE OF DAMAGE AND DETERIORATION AT TIME OF SUBSTANTIAL <br />COMPLETION. <br />1.2. CLEANING: <br />3.6.1 REMOVE BITUMINOUS MARKINGS FROM FINISHED SURFACES IN AREAS <br />WHERE FINISHED SURFACES ARE SOILED BY BITUMEN OR ANY OTHER <br />SOURCE OF SOILING CAUSED BY WORK OF THIS SECTION. CONSULT <br />MANUFACTURER FOR RECOMMENDED CLEANING METHODS AND MATERIALS AND <br />CONFORM TO THEIR ADVICE. <br />3.6.2 REMOVE FINISHED MATERIALS WHICH CANNOT SUCCESSFULLY BE <br />CLEANED, AND REPLACE WITH NEW MATERIALS AT NO EXPENSE TO OWNER. <br />END OF SECTION 07 51 00 <br />SECTION 07 60 00 <br />FLASHING AND SHEET METAL <br />V02212011 <br />1.1. SCOPE: THIS SECTION INCLUDES ALL SHEET METAL WORK, E.G. OVERFLOW SCUPPERS, <br />GUTTER, DOWNSPOUTS, GRAVEL STOP, PARAPET COPING CAP AND COUNTER FLASHING. <br />1.2. RELATED SECTIONS INCLUDE THE FOLLOWING: <br />1.2.1 SECTION 07 51 00 BITUMINOUS BUILT-UP ROOFING. <br />1.2.2 SECTION 07 72 33 ROOF HATCHES. <br />1.3. ALL PENETRATION SEALS ARE PART OF THE WORK OF THIS SECTION WITH THE <br />FOLLOWING EXCEPTIONS: <br />1.3.1 ALL AIR CONDITIONING AND VENTILATION DUCTS, HOOD AND DUCT COVERS IS <br />WORK OF OTHER <br />SECTIONS; FLASHING AND PENETRATION WATERPROOFING IS WORK OF THIS <br />SECTION. <br />1.3.2 ALL FLASHINGS FOR PENETRATIONS THROUGH ROOF MEMBRANE, <br />INSULATION, FLASHING OR OTHER ITEMS MAKING UP THE ROOF ASSEMBLY <br />ARE WORK OF THIS SECTION. <br />1.3.3 ALL CURBS FOR HVAC EQUIPMENT, FANS, VENTS, AND FRESH AIR <br />INTAKES WILL BE FURNISHED BY PUBLIX AND INSTALLED BY THE <br />CONTRACTOR INSTALLING THIS EQUIPMENT. <br />1.3.4 INSTALL ALL LEAD FLASHING UNDER THIS SECTION. SUPPLY LEAD <br />FLASHING UNDER THIS SECTION OR OTHER SECTION AS APPROPRIATE FOR <br />JOB CONDITIONS. COOPERATE WITH ALL TRADES. <br />1.3.5 EQUIPMENT HOUSES LOCATED ON THE ROOF: ALL CURBS AND <br />STRUCTURAL CONNECTIONS WILL BE PROVIDED AND SET WITH THE HOUSES. <br />HOUSES WILL BE EQUIPPED WITH RECEIVERS FOR ROOFING WORK. PROVIDE <br />FLASHING AND OTHER MEASURES TO RENDER THE INSTALLATIONS WATERTIGHT. <br />1.4. PAINTING: ALL PVC VENT PENETRATIONS WILL REQUIRE PAINTING FOR UV PROTECTION. <br />1.5. SUBMITTALS: <br />1.5.1 LETTER OF INTENT (L01): INFORMATION FOR THIS SECTION WILL BE <br />SUBMITTED AS PART OF THE L01 FOR SECTION 07 51 00 BITUMINOUS <br />BUILT-UP ROOFING. <br />1.5.2 SHOP DRAWINGS OF FLASHING DETAILS WILL ACCOMPANY THE SUBMITTAL <br />PACKAGE FOR <br />SECTION 07 51 00 BITUMINOUS BUILT-UP ROOFING. <br />1.5.3 MATERIALS ON SITE: PROVIDE DOCUMENTS STATING THAT MATERIALS <br />COMPLY WITH REQUIREMENTS, INCLUDING CERTIFICATES AND DELIVERY LOGS <br />FOR BULK MATERIALS, AND RECORD ON FIELD TESTING FOR SOFTENING <br />POINT, FLASH POINT, EVT, AND OTHER QUALITY CONTROL TESTING AS <br />REQUIRED. <br />1.6. QUALITY ASSURANCE <br />1.6.1 INSTALLER (ROOFER): <br />1.6.1.1 ALL WORK OF THIS SECTION SHALL BE BY THE APPROVED INSTALLER <br />OF SECTION <br />07 51 00 BITUMINOUS BUILT-UP ROOFING. <br />1.6.1.2 PROVIDE PRODUCTS WHICH ARE ACCEPTABLE TO MANUFACTURER <br />OF PRIMARY PRODUCTS. <br />1.7. PRODUCT HANDLING <br />1.7.1 WHEN MATERIALS ARE STORED OUTSIDE, THEY SHALL BE PLACED ON <br />PLATFORMS THAT ARE RAISED OFF THE GROUND OR ROOF DECK, AND THEY <br />SHALL BE COVERED WITH WATERPROOF COVERINGS. COVERINGS THAT ARE <br />"BREATHABLE" (SUCH AS CANVAS) ARE PREFERRED. <br />1.7.2 ROOFING MATERIALS SHALL BE DELIVERED TO THE JOB SITE JUST PRIOR <br />TO ROOF INSTALLATION WHEN POSSIBLE OR STORED IN CLOSED VANS. <br />1.7.3 ROOF LOADING: DO NOT STORE MATERIALS ON ROOF DECKS, NOR <br />POSITION ROOFING INSTALLATION EQUIPMENT ON ROOF DECKS, IN <br />CONCENTRATIONS EXCEEDING DESIGN LIVE LOADING. <br />2. PRODUCTS <br />2.1. SHEET METAL <br />2.1.1 IN GENERAL, ALL SHEET METAL ITEMS SHALL BE FABRICATED FROM <br />STAINLESS STEEL. USE PREFINISHED SHEET METAL ONLY WHERE REQUIRED <br />TO MATCH OTHER WORK (FACADE) IN THE CENTER. <br />2.1.2 STAINLESS STEEL <br />2.1.2.1 FABRICATE FROM STAINLESS STEEL SHEET COMFORMING TO ASTM A666, <br />TYPE <br />302 OR 304; ANNEALED, 1 /16 HARD, OR 1 /8 HARD. <br />2.1.2.2 USE GAUGE INDICATED BELOW OR AS PERMITTED BY SMACNA <br />GAUGE RECOMMENDATIONS. <br />2.1.2.3 FINISH: NO. 2B 'BRIGHT" COLD ROLLED FINISH. <br />2.1.3 SHEET METAL ACCESSORY MATERIALS: <br />2.1.3.1 WHERE AVAILABLE, USE PRE -ASSEMBLED, PRE -FLASHED <br />ACCESSORIES FOR ALL ROOF PENETRATIONS, GRAVEL STOPS, GUTTERS, <br />AND SUPPORT ASSEMBLIES. <br />2.1.3.2 ACCEPTABLE MANUFACTURER: <br />M-WELD DIVISION OF GAF/U.S. INTEC. <br />2.1.3.3 ACCESSORIES <br />2.1.3.3.1 EDGE METAL: GRAVELGUARD MB WITH PREFORMED OUTSIDE <br />AND INSIDE CORNERS. <br />2.1.3.3.2 VTR FLASHING, ANTENNA SUPPORT FLASHING: 6" ADJUSTABLE <br />M- VENT WITH STAINLESS STEEL DRAW -BAND. <br />2.1.3.3.3 FLUES: MANUFACTURER'S UL COMPLIANT INSULATED DOUBLE <br />WALL FLUE FLASHING. <br />2.1.3.3.4 PENETRATION SEALS: CHEMLINK "CHEMCURB" POLYESTER WITH <br />1 PART POURABLE SEALER. <br />2.1.4 ALUMINUM WALL PANELS: <br />2.1.4.1 PROVIDE PREFINISHED 9/16" THICK .021 GA. "FABRIB" ALUMINUM <br />WALL PANEL AS MANUFACTURED BY FABRAL. <br />2.1.4.2 FASTEN ALUMINUM WALL PANELS TO 18 GA. 7/8" HAT <br />CHANNELS W/ #12 SCREWS Q 8" O.C. HORIZONTAL AND 24" O.C. <br />VERTICAL. <br />2.1.5 SOLDER FOR SHEET METAL: EXCEPT AS OTHERWISE INDICATED OR <br />RECOMMENDED BY METAL <br />MANUFACTURER, PROVIDE -50/50 TIN/LEAD TYPE (ASTM-B32) FOR <br />TINNING AND SOLDERING JOINTS. <br />2.1.6 FASTENERS: SAME METAL AS FLASHING/SHEET METAL OR OTHER <br />NON -CORROSIVE METAL AS RECOMMENDED BY MANUFACTURER. <br />2.1.7 MINIMUM STAINLESS STEEL SHEET THICKNESS: <br />DOWNSPOUTS 24 GA. <br />GUTTERING 20 GA. <br />FM ROLL OVER HANGERS 10 GA. <br />GUTTER SPACE BRACKETS 14 GA. <br />GRAVEL STOP 24 GA. <br />COUNTER FLASHING 24 GA. <br />RAIN COLLARS 24 GA. <br />PARAPET COPINGS (<16" GIRTH 24 GA. <br />PARAPET COPINGS (16" GIRTH AND ABOVE) 22 GA. <br />OTHER SHEET METAL ITEMS: COMPLY WITH SMACNA RECOMMENDATIONS. <br />2.2. FABRICATION OF SHEET METAL ACCESSORIES: <br />2.2.1 SMACNA AND NRCA DETAILS: CONFORM WORK WITH DETAILS SHOWN <br />AND WITH "ARCHITECTURAL SHEET METAL MANUAL" BY SMACNA. COMPLY <br />WITH INSTALLATION DETAILS OF "ROOFING AND WATERPROOFING MANUAL" BY <br />NRCA. <br />2.2.2 PREFABRICATED UNITS AS INDICATED OR PROVIDE STANDARD <br />MANUFACTURED UNITS COMPLYING WITH REQUIREMENTS; FABRICATE FROM <br />SHEET METAL INDICATED. <br />2.2.3 PROVIDE 4" WIDE FLANGES FOR SETTING ON BUILT-UP ROOFING <br />MEMBRANE WITH CONCEALMENT BY COMPOSITION STRIPPING. <br />2.2.4 GUTTERING AND DOWNSPOUTS ON EXTERIOR SIZED AS SHOWN ON <br />DRAWINGS. SUPPORT GUTTERS AT MAXIMUM 36" O.C. AND DOWNSPOUTS AT <br />FIVE (5) FEET ON CENTER. ALL JOINTS, END CAPS AND/OR MITERS SHALL <br />BE RIVETED AND SOLDERED. NO CAULKING PERMITTED. <br />2.2.5 PENETRATION SEALS FOR REFRIGERATION PENETRATIONS PER DETAIL. <br />VERIFY PIPE SIZES PRIOR TO FABRICATION. PENETRATION SEALS FOR <br />ELECTRICAL PENETRATIONS SHALL HAVE CONDUIT SOLDERED TO BASE OF <br />PAN. USE WATER -TIGHT COUPLINGS. <br />2.3. PAINT: THE FOLLOWING PAINTS WILL BE NEEDED FOR ALL PVC PENETRATIONS. <br />2.3.1 PRIMER: SHERWIN WILLIAMS PREPRITE PROBLOCK LATEX SEALER. <br />2.3.2 FINISH: SHERWIN WILLIAMS SUPERPAINT EXTERIOR LATEX SATIN (WHITE). <br />3. EXECUTION <br />3.1. GENERAL INSTALLATION REQUIREMENTS: <br />3.1.1 SEQUENCING OF WORK: <br />3.1.1.1 INSTALL ALL SHEET METAL EDGE TRIM, FLASHINGS, COPINGS, <br />ETC. BEFORE INSTALLATION OF CAP SHEET. STRIP IN IMMEDIATELY. <br />3.1.2 COORDINATE THE INSTALLATION OF INSULATION, ROOFING SHEETS, <br />FLASHINGS, STRIPPING, COATINGS AND SURFACING, SO THAT INSULATION <br />AND FELTS ARE NOT EXPOSED TO <br />PRECIPITATION NOR EXPOSED OVERNIGHT. <br />3.1.3 PROVIDE RAIN COLLARS AT ALL PITCH PANS, WHERE ROUND STOCK IS <br />USED AS ROOF PENETRATION, AND OTHER LOCATIONS WHERE NEEDED. USE <br />STAINLESS DRAW BANDS TO FORM MECHANICAL SEAL WITH COLLAR AND PIPE. <br />3.2. PAINTING: PAINT ALL EXPOSED PVC VENTS (AFTER FLASHING AND BOOTS ARE IN PLACE) <br />WITH ONE COAT OF SPECIFIED SEALER AND TWO COATS OF SPECIFIED FINISH. <br />3.3. CLEANING: <br />3.3.1 CLEAN EXPOSED METAL SURFACES OF SUBSTANCES THAT INTERFERE WITH <br />UNIFORM OXIDATION AND WEATHERING. <br />3.3.2 CLEAN AND NEUTRALIZE FLUX MATERIALS. CLEAN OFF EXCESS SOLDER AND <br />SEALANTS. <br />3.3.3 REMOVE TEMPORARY PROTECTIVE COVERINGS AND STRIPPABLE FILMS, IF <br />ANY, AS SHEET METAL FLASHING AND TRIM ARE INSTALLED. UPON <br />COMPLETION OF INSTALLATION, CLEAN FINISHED SURFACES, INCLUDING <br />REMOVING UNUSED FASTENERS, METAL FILINGS, POP RIVET SEAMS AND <br />PIECES OF FLASHING. MAINTAIN IN A CLEAN CONDITION DURING <br />CONSTRUCTION. <br />3.3.4 REPLACE SHEET METAL FLASHING AND TRIM THAT HAVE BEEN DAMAGED <br />OR HAVE DETERIORATED BEYOND SUCCESSFUL REPAIR BY FINISH TOUCHUP <br />OR SIMILAR MINOR REPAIR PROCEDURES. <br />END OF SECTION 07 60 00 <br />SECTION 07 72 33 <br />ROOF HATCHES <br />V09252015 <br />1.1. SCOPE: THIS SECTION INCLUDES INFORMATION PERTAINING TO ROOF HATCHES. <br />1.2. RELATED SECTIONS INCLUDE THE FOLLOWING: <br />1.2.1 SECTION 07 51 00 BITUMINOUS BUILT-UP ROOFING. <br />1.2.2 SECTION 07 60 00 FLASHING AND SHEET METAL. <br />1.3. SUBMITTALS: <br />1.3.1 LETTER OF INTENT (L01): INDICATE PRODUCT SELECTION ON L01 FOR SECTION <br />07 51 00 BITUMINOUS BUILT-UP ROOFING. <br />1.4. QUALITY ASSURANCE <br />1.4.1 INSTALLER (ROOFER): <br />1.4.1.1 INSTALLER SAME BE SAME AS APPROVED FOR WORK OF SECTION <br />07 51 00 BITUMINOUS BUILT-UP ROOFING. <br />1.5. DELIVERY, HANDLING AND STORAGE <br />1.5.1 PACK, HANDLE AND SHIP PROPERLY LABELED IN HEAVY-DUTY <br />PACKAGING TO PREVENT DAMAGE. <br />2. PRODUCTS <br />2.1. ROOF HATCH: PROVIDE ALUMINUM ROOF HATCH WITH SAFETY POLE: <br />2.1.1 BILCO #S-50 ALUMINUM ROOF HATCH <br />2.1.2 BADCOCK-DAVIS MODEL BRHPA36X3OS1T. FOR HIGH VELOCITY WIND <br />ZONES USE MODEL BRHZA36X30S1T <br />2.2. EXECUTION <br />2.3. INSTALLATION: <br />2.3.1 INSTALL ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. INSTALL <br />TO RESIST EXPOSURE TO WEATHER WITHOUT FAILING, RATTLING AND LEAKING. <br />2.3.2 SAFETY POLE SHOULD BE INSTALLED TO FAR RIGHT OR FAR LEFT SIDE <br />OF OPENING. DO NOT INSTALL SAFETY POLE CENTERED WITH LADDER AS <br />APPROVED. <br />2.3.3 CHECK ROOF HATCH FOR PROPER OPERATION. ADJUST OPERATING MECHANISM <br />AS REQUIRED. CLEAN AND LUBRICATE JOINTS AND HARDWARE. <br />2.4. TOUCH-UP: <br />2.4.1 TOUCH UP FACTORY -PRIMED SURFACES WITH COMPATIBLE PRIMER <br />READY FOR FIELD PAINTING IN ACCORDANCE WITH SECTION 09 91 00 <br />PAINTS. <br />END OF SECTION 07 72 33 <br />SECTION 07 92 00 <br />JOINT SEALANTS <br />V01062015 <br />1.1. SCOPE: THIS SECTION COVERS SEALANTS FOR USE IN ALL LOCATIONS EXCEPT GLAZING. <br />1.2. SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL PROCEDURES. <br />1.3. QUALITY ASSURANCE - SEALANT COMPATIBILITY AND ADHESION TESTING: USE SEALANT <br />MANUFACTURER'S STANDARD TEST METHODS TO DETERMINE WHETHER PRIMING AND <br />OTHER SPECIFIC JOINT PREPARATION TECHNIQUES ARE REQUIRED TO OBTAIN RAPID, <br />OPTIMUM ADHESION OF JOINT SEALANTS TO JOINT SUBSTRATES. <br />2. PRODUCTS <br />2.1. MATERIALS, GENERAL <br />2.1.1 COMPATIBILITY: PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER <br />RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND <br />WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND <br />APPLICATION, AS DEMONSTRATED BY SEALANT MANUFACTURER BASED <br />ON TESTING AND FIELD EXPERIENCE. <br />2.1.2 COLORS OF EXPOSED JOINT SEALANTS: MATCH COLOR OF <br />MATERIALS BEING JOINED IF POSSIBLE. WHERE NOT POSSIBLE, <br />USE COLOR SELECTED TO PROVIDE AN UNOBTRUSIVE FINISHED <br />SURFACE. <br />2.2. ELASTOMERIC JOINT SEALANTS <br />2.2.1 USE SINGLE -COMPONENT URETHANE SEALANTS. IF UNUSUAL <br />CONDITIONS OR TYPE OF WORK TO BE ACCOMPLISHED MAKES THE <br />USE OF MULTI -COMPONENT SEALANTS DESIRABLE, CONTACT PUBLIX <br />ARCHITECT. <br />2.2.2 ELASTOMERIC SEALANTS, GENERAL: ASTM C 920. <br />2.2.3 SEALANTS FOR CONTACT WITH FOOD: COMPLY WITH 21 CFR <br />177.2600. <br />2.2.4 SINGLE -COMPONENT NONSAG URETHANE SEALANT (GUN -GRADE): <br />2.2.4.1 PRODUCTS: <br />BOSTIK INC.; CHEM-CALK 500. TREMCO; <br />DYMONIC FC <br />PECORA CORPORATION; DYNATROL I. <br />POLYMERIC SYSTEMS, INC.; PSI-901. <br />2.2.4.2 TYPE AND GRADE: S (SINGLE COMPONENT) AND NS (NONSAG). <br />2.2.4.3 CLASS: 25. <br />2.2.4.4 EXPOSURE: USE T (TRAFFIC) OR NT (NONTRAFFIC). <br />2.2.4.5 SUBSTRATES: USES M, A, AND, AS APPLICABLE TO JOINT <br />SUBSTRATES INDICATED, 0. <br />2.2.5 SINGLE -COMPONENT POURABLE URETHANE SEALANT: <br />2.2.5.1 PRODUCTS: <br />BOSTIK INC.; CHEM-CALK 950. <br />MAMECO INTERNATIONAL; VULKEM 455 SL. <br />PECORA CORPORATION; NR-201. <br />POLYMERIC SYSTEMS, INC.; FLEXIPRENE PSI-951. <br />2.2.5.2 TYPE AND GRADE: S (SINGLE COMPONENT) AND P (POURABLE) <br />2.2.5.3 CLASS: 25. <br />2.2.5.4 EXPOSURE: USE T (TRAFFIC) AND NT (NONTRAFFIC). <br />2.2.5.5 SUBSTRATES: USES M, A, AND, AS APPLICABLE TO JOINT <br />SUBSTRATES INDICATED, 0. <br />2.3. LATEX JOINT SEALANTS: ASTM C 834. USE WHERE SEALANT WILL BE PAINTED, AND <br />ONLY WHERE JOINT MOVEMENT CANNOT OCCUR. <br />2.3.1 PRODUCTS: <br />BOSTIK INC.; CHEM-CALK 600. PECORA <br />CORPORATION; AC-20. POLYMERIC SYSTEMS, <br />INC.; PSI-701. <br />2.4. JOINT -SEALANT BACKING <br />2.4.1 GENERAL: PROVIDE SEALANT BACKINGS OF MATERIAL AND TYPE <br />THAT ARE NONSTAINING; ARE COMPATIBLE WITH JOINT SUBSTRATES, <br />SEALANTS, PRIMERS, AND OTHER JOINT FILLERS; AND ARE APPROVED <br />FOR APPLICATIONS INDICATED BY SEALANT MANUFACTURER BASED ON <br />FIELD EXPERIENCE AND LABORATORY TESTING. <br />2.4.2 CYLINDRICAL SEALANT BACKINGS: ASTM C 1330, OF SIZE AND <br />DENSITY TO CONTROL SEALANT DEPTH AND OTHERWISE <br />CONTRIBUTE TO PRODUCING OPTIMUM SEALANT PERFORMANCE. <br />TYPE: 0 (OPEN -CELL MATERIAL), OR B (BICELLULAR MATERIAL <br />WITH A SURFACE SKIN). <br />2.4.3 ELASTOMERIC TUBING SEALANT BACKINGS: NEOPRENE, BUTYL, <br />EPDM, OR SILICONE TUBING COMPLYING WITH ASTM D 1056, <br />NONABSORBENT TO WATER AND GAS, AND CAPABLE OF REMAINING <br />RESILIENT AT TEMPERATURES DOWN TO MINUS 26 F (MINUS 32 <br />C). PROVIDE PRODUCTS WITH LOW COMPRESSION SET AND OF SIZE <br />AND SHAPE TO PROVIDE A SECONDARY SEAL, TO CONTROL SEALANT <br />DEPTH, AND OTHERWISE CONTRIBUTE TO OPTIMUM SEALANT <br />PERFORMANCE. <br />2.4.4 BOND -BREAKER TAPE: POLYETHYLENE TAPE OR OTHER PLASTIC <br />TAPE RECOMMENDED BY SEALANT MANUFACTURER FOR PREVENTING <br />SEALANT FROM ADHERING TO RIGID, INFLEXIBLE JOINT -FILLER <br />MATERIALS OR JOINT SURFACES AT BACK OF JOINT WHERE SUCH <br />ADHESION WOULD RESULT IN SEALANT FAILURE. PROVIDE <br />SELF-ADHESIVE TAPE WHERE APPLICABLE. <br />2.5. MISCELLANEOUS MATERIALS <br />2.5.1 PRIMER: MATERIAL RECOMMENDED BY JOINT SEALANT <br />MANUFACTURER WHERE REQUIRED FOR ADHESION OF SEALANT TO <br />JOINT SUBSTRATES INDICATED, AS DETERMINED FROM <br />PRECONSTRUCTION JOINT -SEALANT -SUBSTRATE TESTS AND FIELD <br />TESTS. <br />2.5.2 CLEANERS FOR NONPOROUS SURFACES: CHEMICAL CLEANERS <br />ACCEPTABLE TO MANUFACTURERS OF SEALANTS AND SEALANT <br />BACKING MATERIALS, FREE OF OILY RESIDUES OR OTHER <br />SUBSTANCES CAPABLE OF STAINING OR HARMING JOINT SUBSTRATES <br />AND ADJACENT NONPOROUS SURFACES IN ANY WAY, AND <br />FORMULATED TO PROMOTE OPTIMUM ADHESION OF SEALANTS WITH <br />JOINT SUBSTRATES. <br />2.5.3 MASKING TAPE: NONSTAINING, NONABSORBENT MATERIAL <br />COMPATIBLE WITH JOINT SEALANTS AND SURFACES ADJACENT TO <br />JOINTS. <br />3. EXECUTION <br />3.1 . INSTALLATION <br />3.1.1 SURFACE CLEANING OF JOINTS: CLEAN OUT JOINTS IMMEDIATELY <br />BEFORE INSTALLING JOINT SEALANTS. <br />3.1.1.1 REMOVE FOREIGN MATERIAL FROM JOINT SUBSTRATES <br />THAT COULD INTERFERE WITH ADHESION OF JOINT SEALANT. <br />3.1.1.2 CLEAN POROUS JOINT SUBSTRATE SURFACES BY <br />BRUSHING, GRINDING, BLAST CLEANING, MECHANICAL ABRADING, <br />OR A COMBINATION OF THESE METHODS TO PRODUCE A CLEAN, <br />SOUND SUBSTRATE CAPABLE OF DEVELOPING OPTIMUM BOND <br />WITH JOINT SEALANTS. REMOVE LOOSE PARTICLES REMAINING <br />FROM ABOVE CLEANING OPERATIONS BY VACUUMING OR <br />BLOWING OUT JOINTS WITH OIL -FREE COMPRESSED AIR. <br />3.1.1.3 REMOVE LAITANCE AND FORM -RELEASE AGENTS FROM <br />CONCRETE. <br />3.1.1.4 CLEAN NONPOROUS SURFACES WITH CHEMICAL CLEANERS <br />OR OTHER MEANS THAT DO NOT STAIN, HARM SUBSTRATES, OR <br />LEAVE RESIDUES COULD INTERFERE WITH ADHESION OF JOINT <br />SEALANTS. <br />3.1.2 JOINT PRIMING: PRIME JOINT SUBSTRATES WHERE <br />RECOMMENDED IN WRITING BY JOINT SEALANT MANUFACTURER, <br />BASED ON PRECONSTRUCTION JOINT -SEALANT -SUBSTRATE TESTS <br />OR PRIOR EXPERIENCE. CONFINE PRIMERS TO AREAS OF <br />JOINT -SEALANT BOND; DO NOT ALLOW SPILLAGE OR MIGRATION <br />ONTO ADJOINING SURFACES. <br />3.1.3 MASKING TAPE: USE MASKING TAPE WHERE REQUIRED TO <br />PREVENT CONTACT OF SEALANT WITH ADJOINING SURFACES THAT <br />OTHERWISE WOULD BE PERMANENTLY STAINED OR DAMAGED BY <br />SUCH CONTACT OR BY CLEANING METHODS REQUIRED TO REMOVE <br />SEALANT SMEARS. REMOVE TAPE IMMEDIATELY AFTER TOOLING <br />WITHOUT DISTURBING JOINT SEAL. <br />3.1.4 SEALANT INSTALLATION: COMPLY WITH RECOMMENDATION IN ASTM <br />C 1193 FOR USE OF JOINT SEALANTS AS APPLICABLE TO <br />MATERIALS, APPLICATIONS, AND CONDITIONS INDICATED. <br />3.1.5 INSTALL SEALANT BACKINGS TO SUPPORT SEALANTS DURING <br />APPLICATION AND AT POSITION REQUIRED TO PRODUCE OPTIMUM <br />SEALANT MOVEMENT CAPABILITY. <br />3.1.5.1 DO NOT LEAVE GAPS BETWEEN ENDS OF SEALANT BACKINGS. <br />3.1.5.2 DO NOT STRETCH, TWIST, PUNCTURE, OR TEAR SEALANT <br />BACKINGS. <br />3.1.5.3 REMOVE ABSORBENT SEALANT BACKINGS THAT HAVE <br />BECOME WET BEFORE SEALANT APPLICATION AND REPLACE <br />THEM WITH DRY MATERIALS. <br />3.1.6 INSTALL BOND -BREAKER TAPE BEHIND SEALANTS WHERE <br />SEALANT BACKINGS ARE NOT USED BETWEEN SEALANTS AND BACK <br />OF JOINTS. <br />3.1.7 PLACE SEALANTS SO THEY DIRECTLY CONTACT AND FULLY <br />WET JOINT SUBSTRATES. <br />3.1.7.1 COMPLETELY FILL RECESSES PROVIDED FOR EACH JOINT <br />CONFIGURATION. <br />3.1.7.2 PRODUCE UNIFORM, CROSS -SECTIONAL SHAPES AND <br />DEPTHS THAT ALLOW OPTIMUM SEALANT MOVEMENT CAPABILITY. <br />3.1.8 TOOLING OF NONSAG SEALANTS: IMMEDIATELY AFTER SEALANT <br />APPLICATION AND BEFORE SKINNING OR CURING BEGINS, TOOL <br />SEALANTS TO FORM SMOOTH, UNIFORM BEADS, TO ELIMINATE AIR <br />POCKETS, AND TO ENSURE CONTACT AND ADHESION OF SEALANT <br />WITH SIDE OF JOINT. <br />3.1.8.1 REMOVE EXCESS SEALANTS FROM SURFACES ADJACENT TO <br />JOINT. <br />3.1.8.2 USE TOOLING AGENTS THAT ARE APPROVED BY SEALANT <br />MANUFACTURER AND THAT <br />DO NOT DISCOLOR SEALANTS OR ADJACENT SURFACES. <br />3.1.8.3 JOINT CONFIGURATION: CONCAVE JOINT CONFIGURATION PER <br />FIGURE 5A IN <br />ASTM C 1193, UNLESS OTHERWISE INDICATED. <br />END OF SECTION 07 92 00 <br />WILL BE ALLOWED. <br />2. PRODUCTS <br />2.1. STEEL DOORS AND FRAMES: <br />2.1.1 TYPICAL DOORS: PROVIDE DOORS HAVING 18 GA. STEEL FACE SHEETS <br />FOR INTERIOR APPLICATIONS, 16 OR 14 GA. GALVANIZED FOR EXTERIOR <br />APPLICATIONS. PRIME PAINT ALL SURFACES. <br />2.1.2 EXTERIOR APPLICATIONS MUST HAVE A POLYURETHANE CORE INSULATION WITH <br />A MINIMUM <br />R FACTOR OF 4.75 <br />2.1.3 METAL FRAMES: <br />2.1.3.1 PROVIDE 16 GA. FRAMES IN SIZES AND STYLES SHOWN ON THE <br />DRAWINGS, ALL WELDED, GALVANIZED FOR EXTERIOR APPLICATIONS, WITH <br />MINIMUM THREE ANCHORS PER JAMB OF THE TYPE REQUIRED FOR WALL <br />CONSTRUCTION. PRIME PAINT ALL SURFACES. <br />2.1.3.2 PREPARE FRAMES TO RECEIVE HARDWARE AS DESCRIBED BY ANSI/SDI <br />100. <br />REINFORCE HINGE, LATCH, AND DEADBOLT LOCATIONS AS REQUIRED. <br />2.1.3.3 PROVIDE FOR DEADBOLT INSTALLATION AT JAMB FOR UPPER LEAF OF <br />DUTCH DOOR AT <br />PHARMACY. <br />2.2. LABELED ASSEMBLIES: <br />2.2.1 FIRE DOORS: COMPLY WITH REQUIREMENTS ABOVE. ADDITIONALLY, USE <br />TESTED AND APPROVED FIRE RESISTANT CORE. ATTACH A PERMANENT LABEL <br />SHOWING COMPLIANCE WITH THE REQUIRED LABEL. <br />2.2.2 FRAMES: COMPLY WITH REQUIREMENTS ABOVE. <br />2.3. ACCESSORIES: PROVIDE THREE SILENCERS PER DOOR; AT MASONRY WALLS, PROVIDE 26 <br />GA. MORTAR BOXES TO PROTECT HARDWARE CUTOUTS. LOUVERS SHALL BE <br />SIGHT -PROOF TYPE, 14 GA. STEEL, PRIME PAINTED, GALVANIZED AT EXTERIOR. GLAZING <br />STOPS SHALL BE 20 GA. FLUSH TYPE, PRIME <br />PAINTED, GALVANIZED AT EXTERIOR. <br />2.4. MANUFACTURERS: <br />CECO <br />CURRIES <br />3. EXECUTION <br />3.1. FRAME INSTALLATION: SET FRAMES PLUMB, LEVEL AND TRUE. USE WALL ANCHORS <br />APPROPRIATE FOR EACH TYPE OF ENCLOSING WALL. <br />3.2. DOOR INSTALLATION: HANG DOORS TO PROVIDE SMOOTH OPERATION WITH TIGHT <br />CLOSURE. INSTALL GLAZING AND SILENCERS AFTER DOORS AND FRAMES RECEIVE FINAL <br />PAINT APPLICATION. <br />3.3. FIRE RATED ASSEMBLIES: SET FRAMES AND HANG DOORS IN COMPLIANCE WITH NFPA <br />80. <br />END OF SECTION 08 11 00 <br />SECTION 08 14 00 <br />WOOD DOORS <br />V03172017 <br />1.1. DESCRIPTION OF THE WORK: THIS SECTION COVERS ALL WOOD DOORS AND WOOD <br />DOORS WITH PLASTIC LAMINATE FACES, INCLUDING FABRICATION AND ERECTION. <br />1.2. SUBMITTALS: COMPLETED L01, LIST OF MATERIALS PROPOSED FOR USE, <br />MANUFACTURER'S SPECIFICATIONS, SHOP DRAWINGS AS REQUIRED TO DESCRIBE <br />INTENDED ASSEMBLIES, AND OTHER PERTINENT DETAILS OF PROPOSED INSTALLATION <br />1.3. QUALITY ASSURANCE: PROVIDE PRODUCTS OF ONE MANUFACTURER THROUGHOUT THE <br />PROJECT. <br />COMPLY WITH AW1 1300 FOR MANUFACTURER AND INSTALLATION. <br />1.4. MANUFACTURER'S RECOMMENDATIONS FOR STORAGE, HANDLING, AND PROTECTION SHALL <br />BE FOLLOWED EXACTLY. <br />1.5. NO SUBSTITUTIONS WILL BE ALLOWED. <br />2. PRODUCTS <br />2.1. WOOD DOORS: PROVIDE WOOD DOORS WITH PARTICLE BOARD CORE COMPLYING WITH <br />ANSI A208.ILD2, PAINT GRADE. <br />2.2. FACTORY PREP ALL DOORS TO RECEIVE HARDWARE SPECIFIED. <br />2.3. VIEWLITES: ALL VIEWLITES SHALL BE CLEAR, 1 /4" TEMPERED GLASS, UNLESS OTHERWISE <br />SPECIFIED. MEASURING 6" X 30" OR 18" X 58" (SEE DOOR ELEVATIONS). <br />2.4. VENEER: PROVIDE ALL INTERIOR WOOD DOORS WITH .125 INCH THICK DECORATIVE <br />HIGH-PRESSURE LAMINATE BOTH SIDES. SEE DOOR SCHEDULE FOR LAMINATE COLORS. <br />2.5. ACCESSORIES: PROVIDE THREE SILENCERS PER DOOR. LOUVERS SHALL BE <br />SIGHT -PROOF TYPE FABRICATED FROM 14 GA. STEEL, PRIME PAINTED. GLAZING STOPS <br />AND FRAMES SHALL BE 20 GA. STEEL, PRIME PAINTED. <br />2.6. MANUFACTURERS: <br />VT INDUSTRIES DOORMERICA MARSHFIELD <br />3. EXECUTION <br />3.1. DOOR INSTALLATION: HANG DOORS TO PROVIDE SMOOTH OPERATION WITH TIGHT <br />CLOSURE. INSTALL GLAZING AND SILENCERS AFTER DOORS AND FRAMES RECEIVE FINAL <br />PAINT APPLICATION. <br />END OF SECTION 08 14 00 <br />SECTION 08 17 05 <br />SIDE FOLDING GRILLES <br />V03172017 <br />1.1.1 SECTION INCLUDES: MANUAL SIDE -FOLDING ALUMINUM SECURITY GRILLES <br />WITH STORAGE POCKET. <br />1.2. SUBMITTALS: <br />1.2.1 REFERENCE SECTION 01 33 00 SUBMITTAL PROCEDURES; SUBMIT FOLLOWING <br />ITEMS: <br />1.2.1.1 PRODUCT DATA: INCLUDE PUBLISHED DATA AND SPECIFIC DATA <br />PREPARED FOR THIS PROJECT. <br />1.2.1.2 SHOP DRAWINGS: INCLUDE DETAILED PLANS, ELEVATIONS, REQUIRED <br />CLEARANCES AND ACCESSORIES. <br />1.2.1.3 INSTALLATION INSTRUCTIONS. <br />1.2.1.4 QUALITY ASSURANCE REQUIREMENTS: <br />1.2.1.4.1 MANUFACTURER QUALIFICATIONS. <br />1.2.1.4.2 INSTALLER QUALIFICATIONS. <br />1.2.1.4.3 CERTIFICATES. <br />1.3. QUALITY ASSURANCE: <br />1.3.1 MANUFACTURER QUALIFICATIONS: MINIMUM OF THREE YEARS <br />EXPERIENCE IN THE FABRICATION AND INSTALLATION OF SIDE FOLDING <br />SECURITY GRILLES. <br />1.3.2 INSTALLER QUALIFICATIONS: AUTHORIZED REPRESENTATIVE OF THE <br />MANUFACTURER. <br />1.3.3 CERTIFICATE STATING THAT MATERIALS AND FINISHES COMPLY WITH <br />SPECIFICATIONS. <br />1.3.4 SINGLE SOURCE RESPONSIBILITY: PROVIDE GRILLES, STORAGE POCKET, <br />TRACK AND RELATED PRIMARY COMPONENTS FROM ONE MANUFACTURER FOR <br />EACH TYPE OF GRILLE. PROVIDE SECONDARY COMPONENTS FROM SOURCE <br />ACCEPTABLE TO MANUFACTURER OF PRIMARY COMPONENTS <br />1.3.5 PRE -INSTALLATION CONFERENCE: SCHEDULE AND CONVENE A <br />PRE -INSTALLATION CONFERENCE JUST PRIOR TO COMMENCEMENT OF FIELD <br />OPERATIONS TO ESTABLISH PROCEDURES TO MAINTAIN OPTIMUM WORKING <br />CONDITIONS AND TO COORDINATE THIS WORK WITH RELATED AND ADJACENT <br />WORK. <br />1.4. DELIVERY, STORAGE AND HANDLING <br />1.4.1 REFERENCE SECTION 01 66 00 PRODUCT STORAGE AND HANDLING <br />REQUIREMENTS. <br />1.4.2 DELIVER MATERIALS IN LABELED PROTECTIVE PACKAGES. STORE AND <br />HANDLE IN COMPLIANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />2. PRODUCTS <br />2.1. MANUFACTURERS: <br />DYNAMIC CLOSURES <br />TELEPHONE: 1-800-663-4599; FAX: 1-800-205-6665 <br />E-MAIL: INFO@DYNAMICCLOSURES.COM <br />MOBILFLEX, INC. (NOT AVAILABLE FOR 28 PROTOTYPE) <br />TELEPHONE: 1-800-216-3539; FAX: 1-800-254-3539 <br />CONTACT NAME: PIERRE-LUC ROBERT <br />SUBSTITUTIONS: REFERENCE SECTION 01 25 00 PRODUCT SUBSTITUTION <br />PROCEDURES. <br />2.2. MODELS AND MATERIALS: <br />2.2.1 MODELS: EZ CLOSURE BP (DYNAMIC CLOSURES), POCKET SCREEN (METRO <br />DOOR) OR AEROFLEX (MOBILFLEX). <br />2.2.2 CURTAIN: <br />2.2.2.1 PANELS: TOP AND BOTTOM OF ALUMINUM AND OF SIZES SPECIFIED <br />BY MANUFACTURERS. MAIN PORTION OF PANELS 2" WIDE OF <br />PERFORATED ALUMINUM. PANELS ARE LINKED TOGETHER BY A <br />CONTINUOUS ALUMINUM HINGE (3 1/2" ON CENTER). <br />2.2.2.2 CURTAIN SHALL BE FULLY ASSEMBLED AND INSTALLED IN POCKET <br />BY RESPECTIVE MANUFACTURER. <br />2.2.3 CURTAIN HEIGHT: REFERENCE DRAWINGS. <br />2.2.4 FINISH -EXPOSED ALUMINUM PARTS CLEAR ANODIZED; HIEP IS A "CLEAR <br />ANODIZED" COLOR. <br />2.2.5 LOCKING POSTS: REFERENCE MANUFACTURER'S INSTALLATION DRAWING. <br />DROPBOLTS SHALL BE INSTALLED EVERY 14-16 PANELS AND ALL LOCK <br />MECHANISMS SHALL FACE TO THE OUTSIDE OF THE PHARMACY. <br />2.2.6 LOCKS: THE LOCK TYPE ON GATE SHALL BE SPIC (SMALL FORMAT <br />INTERCHANGEABLE <br />CORE) FOR ALL LOCKING POS T. <br />2.2.7 OVERHEAD TRACK: EXTRUDED ALUMINUM, OF SIZE SPECIFIED BY <br />MANUFACTURER, WITH CONTINUOUS EXTRUDED PROFILE SEAMED TOGETHER <br />BY ALIGNMENT BARS AND TRACK PINS. TRACK TO BE SECURED TO A <br />HEADER THAT WILL CARRY WEIGHT OF COMPLETE CURTAIN. THE WALL <br />CHANNEL SHALL BE FASTENED TO THE OPPOSITE WALL PROPERLY BLOCK <br />AND CONSTRUCTED BY OTHERS. HEADER THAT SUPPORTS THE TRACK IS <br />CONSTRUCTED BY OTHERS. <br />2.2.8 POCKET: WELDED 1 /2" TUBULAR STEEL FRAME THAT IS 6" EXTERIOR <br />SUITABLE FOR COMMERCIAL CONSTRUCTION OF 6" STUD WALLS. INTERIOR <br />CLEAR OPENING WIDTH OF 5" BY HEIGHT OF CURTAIN REQUIRED. POCKET IS <br />ADJUSTABLE TO BE RAISED OR LOWERED UP TO AN INCH. FRONT CORNER <br />ANGLES FLAPS TO COVER POCKET OPENING WITH PIANO HINGES. ANGLES <br />ALSO ACCEPT 1/2" OR 5/8" SHEETROCK. <br />2.2.9 OPERATION: <br />2.2.9.1 MANUAL PULL OPERATION. <br />2.2.9.2 PROVIDE ATTACHED PULL STRAPS ON GRILLES OVER 9'O" (2745 <br />MM) IN HEIGHT AND ALL COUNTER HEIGHT GRILLES. <br />3. EXECUTION <br />3.1. EXAMINATION: <br />3.1.1 EXAMINE SUPPORTS AND OTHER CONDITIONS UNDER WHICH GRILLES ARE TO <br />BE INSTALLED. <br />3.1.2 COORDINATE WITH RESPONSIBLE ENTITY TO CORRECT UNSATISFACTORY <br />CONDITIONS AND DO NOT PROCEED WITH INSTALLATION UNTIL CONDITIONS <br />ARE CORRECTED. <br />3.2. INSTALLATION: <br />3.2.1 FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND APPROVED SHOP <br />DRAWINGS. <br />3.3. ADJUSTING AND CLEANING: <br />3.3.1 TEST OPERATION OF GRILLE AND ADJUST AS NECESSARY TO PROVIDE <br />SMOOTH AND PROPER OPERATION. <br />3.3.2 CLEAN EXPOSED SURFACES USING MANUFACTURERS RECOMMENDED CLEANSER. <br />3.4. DEMONSTRATION: <br />3.4.1 INSTRUCT OWNER'S PERSONNEL IN PROPER OPERATING AND <br />MAINTENANCE PROCEDURES. <br />END OF SECTION 08 17 05 <br />PROVIDE NO LESS THAN A R-VALUE OF 6.0. <br />2.1.1.1 THE FINISH OF THE DOOR CURTAIN SHALL CONSIST OF THE <br />FOLLOWING. <br />2.1.1.1.1 HOT DIPPED GALVANIZED G-90 COATING CONSISTENT <br />WITH ASTM A-525. <br />2.1.1.1.2 BONDERIZED COATING FOR PRIME COAT ADHESION. <br />2.1.1.1.3 CORROSION INHIBITING PRIMER- .2 MILS PER SIDE. <br />2.1.1.1.4 THERMO- SETTING POLYESTER TOP COAT WITH A <br />MINIMUM THICKNESS OF .6 MILS EACH SIDE. <br />2.1.1.1.5 SPECIAL REQUIREMENT - COASTAL AREAS: WHERE <br />EXTERIOR MOUNTED COILING DOORS ARE REQUIRED AT THE <br />AUTOMATIC ENTRANCE DOORS, PAINT ALL EXPOSED METAL <br />R ARY FA ADE COLOR. SEE SECTION <br />SURFACES, MATCHING THE P IM C <br />09 91 00 - PAINTS REGARDING REQUIREMENTS FOR PAINTING <br />EXP SED EXTERIOR METAL SURFACES. <br />0 <br />R HA L CONSIST OF TWO 1 8" ANGLES <br />2.1.1.2 THE BOTTOM BA S L / <br />MECHANICALLY JOINED TOGETHER WITH A 1" DIAMETER VINYL COVERED <br />FOAM EDGE ASTRAGAL CONTINUOUS ALONG THE BOTTOM. THE FINISH ON <br />THE BOTTOM BAR SHALL BE ONE COAT OF RUST INHIBITING PRIME <br />PAINT. <br />2.1.1.3 GUIDES SHALL CONSIST OF STEEL ANGLES BOLTED TOGETHER TO <br />FORM A CHANNEL FOR THE CURTAIN TO TRAVEL. VINYL SNAP -ON <br />WEATHERSTRIPPING SHALL BE FURNISHED CONTINUOUSLY ALONG THE <br />EXTERIOR LEG OF EACH GUIDE. GUIDE ANGLES SHALL BE COATED WITH <br />ONE COAT OF RUST INHIBITING PRIME PAINT. <br />2.1.1.4 THE BRACKETS SHALL BE OF STEEL NOT LESS THAN 1/4" THICK <br />AND FINISHED WITH ONE COAT OF RUST INHIBITING PRIME PAINT. <br />2.1.1.5 THE HOOD SHALL BE FABRICATED FROM 24 GAUGE GALVANIZED <br />STEEL AND SHALL BE FORMED TO FIT THE CURVATURE OF THE <br />BRACKETS. THE HOOD SHALL BE CORRUGATED EVERY 1" ALONG THE <br />CURVATURE FOR THE ENTIRE LENGTH OF THE HOOD. THE HOOD SHALL <br />CONTAIN A WATERPROOF CANVAS BAFFLE TO CONTROL AIR <br />INFILTRATION AND SHALL BE GASKET-ED AT THE WALL TO PREVENT PEST <br />INFILTRATION. <br />2.1.1.5.1 SPECIAL REQUIREMENT - COASTAL AREAS: WHERE <br />EXTERIOR MOUNTED COILING DOORS ARE REQUIRED AT THE <br />AUTOMATIC ENTRANCE DOORS, THE HOOD WILL BE RECTANGULAR IN <br />FORM. HOOD MUST ALSO BE FABRICATED TO ENCLOSE ALL GEARS <br />AND MECHANISMS. <br />2.1.1.5.2 SPECIAL REQUIREMENT - COASTAL AREAS: WHERE <br />EXTERIOR MOUNTED COILING DOORS ARE REQUIRED AT THE <br />AUTOMATIC ENTRANCE DOORS, THE ROLLING DOOR SHALL BE MADE <br />OF 22 GAUGE INTERLOCKING SLATS, NON -INSULATED. THE DOOR <br />MUST BY BE OPERATED BY A REMOVABLE HAND CRANK. NO CHAIN <br />OPERATION IS ALLOWED. <br />2.1.2 MANUFACTURERS: <br />COOKSON, MODEL FCWI CORNELL IRON WORKS <br />OVERHEAD DOOR CORPORATION, MODEL 625 <br />RAYNOR DURACOIL STANDARD <br />SOUTH FLORIDA ROLLING DOORS, INC., MODEL 903 <br />2.2. PUSH-UP COUNTER DOORS (REMODELS ONLY): <br />2.2.1 THE DOOR CURTAIN SHALL BE CONSTRUCTED OF INTERCONNECTED .040 <br />OR .050 EXTRUDED ALUMINUM NO. 8 (1- 5/16" HIGH BY 3/8" DEEP) <br />SLATS. THE CURTAIN SHALL RECEIVE A CLEAR ANODIZED FINISH. <br />2.2.1.1 THE BOTTOM BAR SHALL BE CONSTRUCTED OF TUBULAR EXTRUDED <br />ALUMINUM MEASURING 1- 5/16" DEEP BY 2- 1 /4" HIGH WITH A <br />DOUBLE VINYL ASTRAGAL ON THE BOTTOM EDGE. THE BOTTOM BAR <br />SHALL RECEIVE A CLEAR ANODIZED FINISH. <br />2.2.1.2 THE GUIDES SHALL BE CONSTRUCTED OF EXTRUDED ALUMINUM AND <br />MEASURE 1- <br />3/4" SQUARE. EACH SIDE OF THE CHANNEL PORTION CAPTURING THE <br />CURTAIN SHALL CONTAIN WOOL PILE WEATHERSTRIPPING. THE GUIDES <br />SHALL RECEIVE A CLEAR ANODIZED FINISH. <br />2.2.1.3 THE BRACKETS SHALL BE CONSTRUCTED OF 3/16" THICK DIE CAST <br />ALUMINUM. <br />2.2.1.4 THE BARREL SHALL BE STEEL TUBING OF NOT LESS THAT 4" IN <br />DIAMETER. OIL TEMPERED TORSION SPRINGS SHALL BE CAPABLE OF <br />CORRECTLY COUNTER BALANCING THE WIDTH OF THE CURTAIN. THE <br />BARREL SHALL BE DESIGNED TO LIMIT THE MAXIMUM DEFLECTION TO <br />.03" PER FOOT OF OPENING WIDTH. THE BARREL SHALL RECEIVE ONE(1) <br />COAT OF BRONZE RUST INHIBITING PRIME PAINT. <br />2.2.1.5 THE HOOD SHALL BE FABRICATED FROM .040 ALUMINUM AND <br />TH HOOD SHALL <br />SHALL BE FORMED TO FIT THE SQUARE BRACKETS E <br />RECEIVE A CLEAR ANODIZED FINISH. <br />2.2.2 MANUFACTURERS: <br />COOKSON, MODEL CD8-1 <br />CORNELL IRON WORKS <br />OVERHEAD DOOR CORPORATION, MODEL 652 <br />RAYNOR, DURASHUTTER SELECT METRO DOOR, <br />METRO -GUARD <br />DYNAMIC ENCLOSURES, MODEL LIFT -READY ROLLING GRILLES "VENTANA" <br />2.2.3 OPERATION: <br />2.2.3.1 CHAIN OPERATED OVERHEAD COILING DOORS SHALL OPEN AND <br />CLOSE WITH A MAXIMUM OF 30 POUNDS OF EFFORT UTILIZING AN <br />ENDLESS CHAIN AND CAST IRON REDUCTION GEARS. <br />2.2.3.2 PUSH-UP OPERATED DOORS SHALL OPEN AND CLOSE WITH A <br />MAXIMUM OF 30 POUNDS OF EFFORT UTILIZING FINGER LIFTS IN THE <br />BOTTOM BAR. <br />2.2.4 LOCKING MECHANISM: <br />2.2.4.1 THE OVERHEAD COILING DOOR CHAIN SHALL BE SECURED BY <br />MEANS OF A CHAIN LOCK. <br />2.2.4.2 SPECIAL REQUIREMENT - COASTAL AREAS: HAND CRANK OPERATED <br />DOORS SHALL HAVE STANDARD SLIDE BOLT LOCKING MECHANISMS ON <br />COIL SIDE OF DOOR THAT CAN BE SECURED BY PADLOCKS. <br />2.2.4.3 THE PUSH-UP DOOR SHALL BE SECURED BY MEANS OF A <br />CONCEALED SLIDING BOLT DEADLOCK IN THE BOTTOM BAR OPERATED BY <br />A CYLINDER LOCK. CYLINDER LOCK MUST BE RE-KEYABLE. <br />2.2.5 VISION PANEL: IN DOORS NOT REQUIRED TO MEET MISSILE IMPACT <br />RESISTANCE, PROVIDE VISION SLATS 12"WIDE X 6 SLATS HIGH. BOTTOM OF <br />VISION PANEL SHOULD START AT APPROXIMATELY 5' A.F.F. <br />3. EXECUTION <br />3.1. INSTALLATION: ALL COILING INSULATED AND PUSH-UP COUNTER DOORS SHALL BE <br />INSTALLED BY A MANUFACTURER'S AUTHORIZED INSTALLER AND WILL BE IN <br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND STANDARDS. <br />3.2. WARRANTY: ALL COILING INSULATED AND PUSH-UP COUNTER DOORS SHALL BE <br />WARRANTED AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE <br />YEAR FROM THE TIME OF INSTALLATION. <br />END OF SECTION 08 33 23 <br />SECTION 08 38 00 <br />TRAFFIC DOORS <br />V06012017 <br />1.1. DESCRIPTION OF WORK: THIS SECTION COVERS ALL TRAFFIC DOORS, INCLUDING <br />FABRICATION AND ERECTION. <br />1.2. MANUFACTURER'S RECOMMENDATIONS FOR STORAGE, HANDLING AND PROTECTION SHALL <br />BE FOLLOWED EXACTLY. <br />1.3. WARRANTY <br />1.3.1 PROVIDE MANUFACTURER'S STANDARD 1 YEAR LIMITED WARRANTY FOR <br />TRAFFIC DOORS AND ALL RELATED PARTS. <br />1.3.2 ALL OTHER WARRANTIES AND BONDS ARE TO BE IN ACCORDANCE WITH <br />SECTION 01 77 00 <br />CLOSEOUT PROCEDURES. <br />2. PRODUCTS <br />2.1. ACCEPTABLE MANUFACTURERS <br />2.1.1 TRAFFIC DOOR MANUFACTURERS: SUBJECT TO COMPLIANCE WITH <br />REQUIREMENTS, PROVIDE PRODUCTS OF THE FOLLOWING: <br />CHASE INDUSTRIES INC./SENECA HOLDINGS NATIONAL <br />ACCOUNT CONTACT: NIKKI MORRISSEY <br />EMAIL: NMORRISSEY®SENECA.COM <br />OFFICE (269) 492-3934 <br />FAX (800) 245-7045 <br />NATIONAL SALES REP: BEN FRANCO <br />OFFICE: (419) 280 8176 <br />2.2. TRAFFIC DOORS <br />2.2.1 DOORS SHALL BE DURULITE "STANDARD" TRAFFIC DOORS CONSTRUCTED <br />WITH THE OUTER SKIN OF MONOLITHICALLY FORMED, ROTATIONALLY MOLDED, <br />CROSS LINKED HIGH DENSITY 1 / <br />8"POLYETHYLENE AND A TEXTURED FINISH. DOOR PANEL THICKNESS SHALL BE 1 <br />7/8". <br />2.2.2 INSULATION CORE MATERIAL SHALL BE A HIGH DENSITY, <br />FOAMED -IN -PLACE, RIGID CFC-FREE URETHANE INSULATION. MATERIAL SHALL <br />BE FOAMED -IN -PLACE AND PROVIDE AN R-VALUE OF <br />10.83. <br />2.2.3 POLYETHYLENE TEAR DROP BUMPERS SHALL BE 36 INCHES HIGH AND <br />FACTORY INSTALLED ON BOTH SIDES OF EACH LEAF USING STAINLESS STEEL <br />PANEL INSERTS AND FASTENERS. COLOR: BLACK. <br />2.2.4 PROVIDE 11" INDUSTRIAL LOWER HINGE GUARDS. <br />2.3. TRAFFIC DOOR HARDWARE <br />2.3.1 PROVIDE MANUFACTURER'S STANDARD GRAVITY RETURN V-CAM SYSTEM <br />CONSISTING OF A DUCTILE IRON V-CAM WITH A UHMW SLEEVE AND CAST <br />ALUMINUM CAM FOLLOWER HOUSING WITH A NEEDLE BEARING ROLLER. THE <br />ROLLER ASSEMBLY SHALL BE SECURELY CLAMPED ONTO THE SHAFT TO <br />ALLOW HORIZONTAL AND VERTICAL ADJUSTMENT OF THE DOOR. <br />2.3.2 AT LOCATIONS INDICATED ON DRAWINGS, PROVIDE LOW-RISE V-CAM AND <br />BULB LEADING EDGE GASKET TO COMPLY WITH THE ADA ACCESSIBILITY <br />GUIDELINES. <br />2.4. TRAFFIC DOOR SEALS <br />2.4.1 DOORS SHALL BE FULLY GASKETED WITH ALL GASKETS FACTORY APPLIED <br />WITHOUT THE USE OF METAL STRIPS OR FASTENERS OF ANY TYPE. <br />2.5. TRAFFIC DOOR VISION PANELS <br />2.5.1 WINDOW GLAZING SHALL BE 1/8" POLYCARBONATE. ALL WINDOWS SHALL <br />BE FACTORY INSTALLED AND SEALED. THE EXPOSED SURFACE OF THE <br />WINDOW SHALL BE RECESSED A MINIMUM OF 1 /8" FROM THE FACE OF THE <br />DOOR TO PROTECT THE SURFACE FROM ABRASION FROM PASSING LOADS. <br />2.5.2 WINDOW SIZE SHALL BE 20.5" X 22" <br />2.5.3 MAXIMUM HEIGHT FROM FINISH FLOOR TO THE BOTTOM OF THE VIEWING <br />AREA SHALL NOT EXCEED 48 INCHES. <br />2.6. TRAFFIC DOOR FINISH/COLOR <br />2.6.1 PRE -FINISHED COLOR: SEE DOOR SCHEDULE FOR COLOR SELECTION. <br />3. EXECUTION <br />3.1. INSTALL SPECIAL DOORS COMPLETE WITH NECESSARY HARDWARE AND ACCESSORIES IN <br />ACCORDANCE WITH FINAL SHOP DRAWINGS, MANUFACTURER'S INSTRUCTIONS AND AS <br />SPECIFIED HEREIN. <br />3.2. ALL ASSEMBLIES MUST BE INSTALLED PLUMB, LEVEL AND PROPERLY ALIGNED. <br />3.3. UPON COMPLETION OF INSTALLATION, LUBRICATE, TEST AND ADJUST DOORS TO OPERATE <br />EASILY, FREE FROM WARP, TWIST OR DISTORTION. <br />3.4. ALL DOORS SHALL BE ADA COMPLIANT AND BE ADJUSTED TO ENSURE THE DOOR <br />CLOSING SWEEP PERIOD AND DOOR OPENING FORCE AS OUTLINED IN THE MOST <br />CURRENT EDITION OF THE ADA ACCESSIBILITY GUIDELINES AND THE FACBC. <br />END OF SECTION 08 38 00 <br />SECTION 08 42 29 <br />AUTOMATICENTRANCES <br />V07212017 <br />1.1. THIS SECTION CONTAINS INFORMATION NORMALLY FOUND IN SECTION 08 81 00 GLASS <br />GLAZING. <br />1.2. WIND LOADING: CONFORM TO THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING <br />JURISDICTION. <br />1.3. WARRANTIES: INSULATING GLASS PANELS: MANUFACTURER'S STANDARD TEN YEAR <br />WARRANTY AGAINST ALL DEFECTS. <br />1.4. SUBMITTALS <br />1.4.1 SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL <br />PROCEDURES. <br />1.4.2 SHOP DRAWINGS: <br />1.4.2.1 SUBMIT SHOP DRAWINGS IN SUFFICIENT DETAIL TO SHOW <br />FABRICATION, INSTALLATION, ANCHORAGE, AND INTERFACE OF THE WORK <br />OF THIS SECTION WITH THE WORK ADJACENT. <br />1.4.2.2 IN JURISDICTIONS WHERE NOTICE OF ACCEPTANCE (NOA) IS <br />REQUIRED (AS DESCRIBED IN SECTION 2.1.2): SUBMIT SHOP DRAWINGS <br />SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF <br />FLORIDA CERTIFYING THAT ALL REQUIREMENTS OF COUNTY REGULATIONS <br />ARE MET BY DESIGN PROPOSED. <br />1.4.2.3 ALL AUTOMATIC DOOR ENTRANCES MUST BE COMPLIANT WITH <br />ANSI/BHMA <br />156.10 ACCESSIBILITY STANDARDS. <br />2. PRODUCTS <br />2.1. AUTOMATIC ENTRANCE DOORS: <br />2.1.1 STANDARD PACKAGE: BESAM (ASSA ABLOY) SL 500 SERIES <br />AUTO -SLIDE AUTOMATIC SLIDING ENTRANCES. WHERE APPLICABLE, INTERIOR <br />DOOR PACKAGE SHALL INCLUDE TRANSOM W/ 1/4" TEMPERED GLASS. <br />2.1.2 HIGH VELOCITY WIND ZONES: BESAM(ASSA ABLOY) SL 500 <br />Y HIS ONDITION IS <br />"HURRICANE" FOR EXTERIOR APPLICATIONS ONL T C <br />APPLICABLE IN THE FOLLOWING LOCATIONS OR AS REQUIRED IN THE <br />DRAWINGS: <br />2.1.2.1 FLORIDA: ENTIRE STATE. MUST MEET ASSEMBLY REQUIREMENTS <br />AS STATED IN APPROVED MIAMI-DADE COUNTY NOTICE OF ACCEPTANCE <br />(NOA) AND FLORIDA PRODUCT APPROVAL. <br />2.1.2.2 GEORGIA: 10 MILES WITHIN THE COAST LINE <br />2.1.2.3 SOUTH CAROLINA: 10 MILES WITHIN THE COAST LINE <br />2.1.2.4 ALABAMA: 10 MILES WITHIN THE COAST LINE <br />2.1.2.5 NORTH CAROLINA: 10 MILES WITHIN THE COAST LINE <br />2.1.2.6 VIRGINIA: 10 MILES WITHIN THE COAST LINE <br />2.1.3 SLIDE ACTION: PROVIDE BI-PARTING, BI-PASSING, OR TELESCOPING <br />ACTION AS SHOWN ON THE DRAWINGS. <br />2.1.4 FINISH: CLEAR ANODIZED ALUMINUM. <br />2.1.5 COORDINATE GLAZING, ELECTRICAL, CONTROL WIRING, ETC. WITH OTHER TRADES <br />AS REQUIRED. <br />2.1.6 GLAZING FOR AUTOMATIC DOORS AND SIDELIGHTS: <br />2.1.6.1 IN AREAS LISTED AS HIGH VELOCITY WIND ZONES, PROVIDE <br />LAMINATED GLASS COMPLYING WITH ASTM C-1172, KIND LA, WHEN <br />STORE IS LOCATED IN ONE OF THE ZONES LISTED IN SECTION 2.1.2 <br />2.1.6.1.1 PROVIDE EVIDENCE OF PROJECT JURISDICTION PRODUCT APPROVAL. <br />2.1.6.1.2 GLASS: 7/16" OR 9/16" LAMINATED IMPACT GLASS, OUTER LITES <br />1/4" ANNEALED FLOAT GLASS, QUALITY Q3, LAMINATED ON BOTH SIDES OF <br />INNER PLASTIC LAYER, IN SIZES AS REQUIRED. <br />2.1.6.2 WHEN THE STORE IS NOT LOCATED IN A HIGH VELOCITY WIND <br />ZONE, AS OUTLINED IN SECTION 2.1.2, USE 1 /4" CLEAR TEMPERED <br />FLOAT GLASS, ASTM C- <br />1036, QUALITY 03. <br />2.1.6.3 TRANSOM PANELS SHALL BE OF THE SAME TYPE OF GLAZING <br />AS USED IN THE AUTOMATIC DOORS. <br />2.1.6.4 INTERIOR GLAZING: 1 /4" CLEAR TEMPERED FLOAT GLASS, ASTM <br />C-1036, QUALITY Q3. <br />2.2. SEALANTS FOR GLAZING: <br />2.2.1 WHERE SEALANTS ARE USED IN CONJUNCTION WITH GLAZING SYSTEMS, <br />USE ONLY THOSE RECOMMENDED BY THE MANUFACTURER OF THE GLAZING <br />SYSTEM. <br />2.2.2 UNDER NO CIRCUMSTANCES SHALL WET SEALANTS BE INTRODUCED INTO <br />GLAZING SYSTEMS TO PROVIDE PRIMARY WEATHERPROOFING OR <br />WATERPROOFING. <br />2.2.3 WHERE SEALANTS FOR PERIMETERS OF GLAZING SYSTEMS ABUT OTHER <br />MATERIALS, USE SEALANTS AS DESCRIBED IN SECTION 07 92 00 JOINT <br />SEALANTS. <br />3. EXECUTION <br />3.1. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE <br />PERFORMED. <br />CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF <br />THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE <br />CORRECTED. <br />3.2. COORDINATE AS REQUIRED WITH OTHER TRADES TO ASSURE PROPER PROVISION IN THE <br />WORK OF THOSE TRADES FOR INTERFACE WITH THE WORK OF THIS SECTION. <br />3.3. ALL TRACKS FOR THE INTERIOR ENTRANCE DOORS MUST BE INSTALLED TO THE <br />CONCRETE SLAB PRIOR TO THE BEGINNING OF TERRAZZO INSTALLATION. USE ADEQUATE <br />SHIMMING TO ENSURE TOP OF TRACK IS AT FINISH FLOOR LEVEL (SLAB IS DEPRESSED <br />APPROXIMATELY 5/8"). <br />3.4. MAKE MEASUREMENTS AS REQUIRED IN THE FIELD TO ASSURE PROPER FIT. <br />3.5. ALL ALUMINUM SASH SHALL BE CUT TO FIT, FILED AND INSTALLED TO PROVIDE <br />HAIRLINE FIT AT JOINTS, WITH SMOOTH CONTINUITY OF LINE AND ACCURATE RELATION <br />OF PLANES AND ANGLES. EXPOSED CAULKING SHALL NOT BE USED. <br />3.6. PREPARE FOR, RECEIVE, AND INSTALL THE FINISH HARDWARE FURNISHED UNDER <br />SECTION 08 71 00 <br />DOOR HARDWARE. <br />3.7. GLAZING AND SETTING <br />3.7.1 SASH SHALL BE CLEAN AND DRY BEFORE GLAZING. DO NOT GLAZE IN <br />DAMP OR DUSTY WEATHER OR WHEN TEMPERATURE IS LOWER THAN 40 <br />DEGREES FAHRENHEIT. <br />3.7.2 IMPROPERLY SET GLASS OR GLASS WHICH DOES NOT FULLY MEET <br />REQUIREMENTS OF ITS GRADE WILL NOT BE ACCEPTED AND MUST BE <br />REPLACED TO SATISFACTION OF ARCHITECT WITHOUT <br />COST TO OWNER. <br />3.8. CLEANING AND ACCEPTANCE: UPON COMPLETION OF PROJECT: REPLACE ALL CRACKED, <br />STAINED OR BROKEN GLASS AT NO COST TO OWNER. REMOVE ALL TRACES OF PAINT <br />AND ETC., AND THOROUGHLY CLEAN ALL SASH BEFORE FINAL ACCEPTANCE OF PROJECT. <br />END OF SECTION 08 42 29 <br />SECTION 08 43 13 <br />ALUMINUM -FRAMED STOREFRONTS <br />V04182018 <br />1.1. THIS SECTION CONTAINS INFORMATION NORMALLY FOUND IN SECTION 08 81 00 GLASS <br />GLAZING. <br />1.2. WIND LOADING: CONFORM TO THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING <br />JURISDICTION, <br />1.3. WARRANTIES: INSULATING GLASS PANELS: MANUFACTURER'S STANDARD TEN YEAR <br />WARRANTY AGAINST ALL DEFECTS. <br />1.4. SUBMITTAL <br />1.4.1 SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL <br />PROCEDURES. <br />1.4.2 SHOP DRAWINGS: <br />1.4.2.1 SUBMIT SHOP DRAWINGS IN SUFFICIENT DETAIL TO SHOW <br />FABRICATION, INSTALLATION, ANCHORAGE, AND INTERFACE OF THE WORK <br />OF THIS SECTION WITH THE WORK ADJACENT. <br />2. PRODUCTS <br />2.1. ALUMINUM FRAMING: <br />2.1.1 SIZES AND DESIGNS AS SHOWN ON DRAWINGS. INCLUDE ALL SASH, <br />CORNER CAPS, AND COVERS, WIND REINFORCEMENT, AND ALL OTHER <br />COMPONENTS REQUIRED FOR A SECURE, WATERTIGHT INSTALLATION. <br />2.1.2 INTERIOR AND EXTERIOR FINISH SHALL BE CLEAR ANODIZED ALUMINUM, <br />AA-M12-C12- A31. <br />2.1.3 APPROVED MANUFACTURERS: KAWNEER <br />VI STAWALL <br />U.S.ALUMINUM <br />TRULITE PPG TUBELITE YKK <br />AMERICAN PRODUCTS, INC (API) <br />2.2. MANUFACTURER'S LABELS, SHOWING STRENGTH AND QUALITY, ARE REQUIRED ON ALL <br />GLASS, AND ARE NOT TO BE REMOVED UNTIL INSPECTED AND APPROVED BY PUBLIX' <br />REPRESENTATIVE. ALL GLASS SHALL CONFORM TO FED SPEC DD-6-451A. TEMPERED <br />GLASS SHALL BE SO MARKED, PERMANENTLY, IN AN INCONSPICUOUS LOCATION ON THE <br />PANEL. <br />2.3. EXTERIOR GLAZING: <br />2.3.1 LAMINATED GLAZING: 9/16" MISSILE IMPACT TO BE USED FOR SHELL <br />GLAZING AND PUBLIX- DESIGNED FACADE GLAZING (DEVELOPER -DESIGNED <br />FACADE GLAZING EXEMPT) IN THE FOLLOWING LOCATIONS OR AS REQUIRED IN <br />THE DRAWINGS: <br />2.3.1.1 FLORIDA: ENTIRE STATE. MUST MEET ASSEMBLY REQUIREMENTS <br />AS STATED IN APPROVED MIAMI-DADE NOTICE OF ACCEPTANCE (NOA) <br />AND FLORIDA PRODUCT APPROVAL. <br />2.3.1.2 GEORGIA: 10 MILES WITHIN THE COAST LINE <br />2.3.1.3 SOUTH CAROLINA:10 MILES WITHIN THE COAST LINE <br />2.3.1.4 ALABAMA: 10 MILES WITHIN THE COAST LINE <br />2.3.1.5 NORTH CAROLINA: 10 MILES WITHIN THE COAST LINE <br />2.3.1.6 VIRGINIA: 10 MILES WITHIN THE COAST LINE <br />2.3.2 APPROVED PRODUCTS: <br />SAFETY PLUS -II, GLASSLAM NGI <br />SAF-GLAS, IMPACT SECURITY PRODUCTS, INC. <br />STORMGARD, VIRACON <br />STORMGLASS, OLDCASTLE <br />PPG <br />2.3.3 ELSEWHERE, PROVIDE SEALED INSULATING PANELS COMPOSED OF TWO <br />LITES 1/4" CLEAR TEMPERED FLOAT GLASS, IN SIZES AS DESCRIBED ON <br />DRAWINGS AND VERIFIED IN FIELD. <br />2.3.3.1 GLASS: ASTM C-1036, QUALITY Q3. <br />2.3.3.2 SEALED PANELS: ASTM E-774, CLASS B. <br />2.3.4 EXTERIOR STOREFRONT DOOR (WHERE APPLICABLE). THE FOLLOWING ITEMS <br />ARE TO BE <br />INCLUDED WITH THE DOOR AND PROVIDED BY THE STORE FRONT DOOR PROVIDER: <br />1 EA. DOOR CLOSER <br />1 EA. DOOR PULL <br />1 EA. PUSH BAR <br />1 EA. THUMB TURN <br />2.4. INTERIOR GLAZING: 1/4" CLEAR TEMPERED FLOAT GLASS, ASTM C-1036, QUALITY 03, <br />IN SIZES AS REQUIRED. <br />2.5. SEALANTS FOR GLAZING: <br />2.5.1 WHERE SEALANTS ARE USED IN CONJUNCTION WITH GLAZING SYSTEMS, <br />USE ONLY THOSE RECOMMENDED BY THE MANUFACTURER OF THE GLAZING <br />SYSTEM. <br />2.5.2 UNDER NO CIRCUMSTANCES SHALL WET SEALANTS BE INTRODUCED INTO <br />GLAZING SYSTEMS TO PROVIDE PRIMARY WEATHERPROOFING OR <br />WATERPROOFING. <br />2.5.3 WHERE SEALANTS FOR PERIMETERS OF GLAZING SYSTEMS ABUT OTHER <br />MATERIALS, USE SEALANTS AS DESCRIBED IN SECTION 07 92 00 JOINT <br />SEALANTS. <br />3. EXECUTION <br />3.1. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE <br />PERFORMED. <br />CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF <br />THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE <br />CORRECTED. <br />3.2. COORDINATE AS REQUIRED WITH OTHER TRADES TO ASSURE PROPER PROVISION IN THE <br />WORK OF THOSE TRADES FOR INTERFACE WITH THE WORK OF THIS SECTION. <br />3.3. MAKE MEASUREMENTS AS REQUIRED IN THE FIELD TO ASSURE PROPER FIT. <br />3.4. ALL ALUMINUM SASH SHALL BE CUT TO FIT, FILED AND INSTALLED TO PROVIDE <br />HAIRLINE FIT AT JOINTS, WITH SMOOTH CONTINUITY OF LINE AND ACCURATE RELATION <br />OF PLANES AND ANGLES. EXPOSED <br />CAULKING SHALL NOT BE USED. <br />3.5. GLAZING AND SETTING <br />3.5.1 SASH SHALL BE CLEAN AND DRY BEFORE GLAZING. DO NOT GLAZE IN <br />DAMP OR DUSTY WEATHER OR WHEN TEMPERATURE IS LOWER THAN 40 <br />DEGREES FAHRENHEIT. <br />3.5.2 COORDINATE WITH OTHERS TO SEE THAT SUFFICIENT BLOCKING IS RIGIDLY <br />IN PLACE AND THAT FINISH MATERIAL WILL FIT SILL COVERS, JAMBS, ETC. <br />INSTALL STORE FRONT SASH SECURELY AND NEATLY AND CAULK FULLY TO <br />PRODUCE WATERTIGHT AREA. ANCHOR DIVISION BARS TO STOOL FRAMING AND <br />WOOD GROUND ABOVE. <br />3.5.3 IMPROPERLY SET GLASS OR GLASS WHICH DOES NOT FULLY MEET <br />REQUIREMENTS OF ITS GRADE WILL NOT BE ACCEPTED AND MUST BE <br />REPLACED TO SATISFACTION OF ARCHITECT WITHOUT COST TO OWNER. <br />3.6. CLEANING AND ACCEPTANCE: UPON COMPLETION OF PROJECT: REPLACE ALL CRACKED, <br />STAINED OR BROKEN GLASS AT NO COST TO OWNER. REMOVE ALL TRACES OF PAINT <br />AND ETC., AND THOROUGHLY CLEAN ALL SASH BEFORE FINAL ACCEPTANCE OF PROJECT. <br />END OF SECTION 08 43 13 <br />^� <br />W <br />10 <br />N <br />CD <br />O <br />-1 <br />�N <br />0 � <br />00 <br />U <br />� <br />U <br />"(s <br />' ' <br />Q <br />5 <br />U <br />V <br />O n <br />``0 ``O� <br />W �/ <br />`% <br />U <br />� "g <br />r- r- <br />wA <br />' <br />00 <br />0 <br />� <br />� � <br />A <br />m <br />0 <br />N <br />Q co <br />N <br />Z W M <br />m z F- N <br />w W Qi <br />U � <br />� U� O <br />F_ <br />o O <br />w w <br />o a <br />U <br />VJ <br />F_ <br />W <br />�Y_ <br />w <br />cQ a <br />G <br />O. a <br />nW �v- <br />` L g M <br />�ZOv- <br />/)� a <br />V) O 2 <br />M <br />U U_ <br />X <br />w M6 = Z <br />z ■.. aW <br />I- � C) QY <br />Z M _7 <br />w <br />J <br />U <br />" <br />r <br />�4t <br />VJ <br />Z <br />O <br />CG <br />G <br />O <br />) <br />w <br />\_ (V <br />/" o <br />2 M <br />IT <br />0- � <br />W m <br />M <br />M <br />N o <br />w <br />O <br />LL. <br />> <br />J J <br />w m <br />J_ <br />Z _j J = <br />0 (7 � <br />O Z) M a <br />a �N <br />v <br />2 <br />a(L <br />_j <br />0g <br />•5 <br />bA • <br />WO <br />0 <br />U� Z <br />U J <br />(U fY <br />Z) <br />Z <br />C< <br />G <br />F- <br />U <br />W <br />J <br />�0 <br />LU � r <br />H <br />w <br />w <br />s <br />• <br />�.• <br />' `! <br />_ <br />0 <br />•"0 <br />_ <br />� <br />v"• <br />�• <br />w <br />rn <br />a m <br />•' r <br />a <br />��� '•. <br />.`� <br />�` <br />U <br />`S ••�RE <br />.. <br />U <br />9 <br />0 <br />a <br />8 <br />m <br />N <br />N <br />J <br />H <br />f- <br />m <br />w <br />� <br />CO <br />U) <br />J <br />w <br />o <br />rn <br />O <br />o <br />z <br />M <br />" <br />U <br />� <br />00 <br />N <br />w <br />N <br />o <br />z <br />� <br />U <br />w <br />U <br />� <br />�- <br />� <br />= <br />� <br />¢ <br />a <br />0 <br />0 <br />U <br />WW 2019 <br />Construction, <br />