<br />CONTINUE OF SECTION 07 51 00
<br />3.4. ROOF MEMBRANE INSTALLATION:
<br />3.4.1 SHINGLING OF PLIES: EXCEPT AS OTHERWISE INDICATED, INSTALL
<br />MEMBRANE WITH PLY SHEETS SHINGLED UNIFORMLY TO ACHIEVE REQUIRED
<br />NUMBER OF PLIES OF MEMBRANE THROUGHOUT. SHINGLE IN PROPER
<br />DIRECTION TO SHED WATER ON EACH AREA OF ROOFING.
<br />3.4.2 BROOM IN EACH PLY AS DIRECTED BY MANUFACTURER. USE BROOM
<br />APPROVED BY MANUFACTURER.
<br />3.4.3 CANT STRIPS/TAPERED EDGE STRIPS: EXCEPT AS OTHERWISE SHOWN, INSTALL
<br />PREFORMED
<br />45 DEG. INSULATION CANT STRIPS AT JUNCTURES OF BUR MEMBRANE WITH
<br />VERTICAL SURFACE. PROVIDE PREFORMED TAPERED EDGE STRIPS AT AREAS
<br />SHOWN ON DRAWINGS AS NEEDED TO DIVERT WATER.
<br />3.4.4 INTER -PLY SHEETS: PROVIDE THE NUMBER AND TYPE(S) OF PLY SHEETS
<br />(FELTS) INDICATED, LAPPED (SHINGLED) AMOUNT AS REQUIRED TO FORM A
<br />CONTINUOUS, UNIFORM MEMBRANE WITH BITUMEN MOPPINGS BETWEEN
<br />SHEETS SO THAT PLY SHEET DOES NOT TOUCH PLY SHEET. EXTEND
<br />BUILT-UP ROOFING MEMBRANE TO 2" (NOMINAL) ABOVE TOP EDGE OF CANT
<br />STRIP AND TERMINATE.
<br />3.4.5 ALL EDGE METAL SHALL BE INSTALLED BEFORE INSTALLATION OF CAP
<br />SHEET. BACKWATER LAPS ARE NOT ALLOWED.
<br />3.4.6 INSTALL CAP SHEET IN STRICT COMPLIANCE WITH MANUFACTURER'S
<br />INSTRUCTIONS.
<br />3.4.6.1 AT HEAD LAPS, CUT TEE JOINTS 45 DEGREES. ROUND EXPOSED
<br />CORNERS.
<br />3.4.6.2 PROVIDE ADDITIONAL LAYER OF CAP SHEET AT DOORS OF
<br />MECHANICAL EQUIPMENT ROOMS AND AT ROOF HATCHES.
<br />3.4.7 MEMBRANE FLASHINGS:
<br />3.4.7.1 PROVIDE 2 PLY BASE FLASHING AT ALL ANGLE CHANGES
<br />CONSITING OF 1 PLY OF ASTM D-2178 TYPE IV GLASS FELT SET IN
<br />HOT MOPPING OF TYPE IV ASPHALT FOLLOWED BY 1 PLY OF SBS CAP
<br />SHEET (SAME MATERIAL AS ROOFING CAP SHEET) SET IN A CONTINUOUS
<br />TROWELING OF MATRIX 201. SIMILAR TO U.S. INTEC DETAIL SBS5.
<br />CORNERS ARE TO BE FLASHED PER DETAILS SBS 11 AND SBS 12
<br />(FORMERLY FLEX3).
<br />3.4.7.2 AT HORIZONTAL METAL FLANGES, I.E. GRAVEL GUARD MB,
<br />ELECTRICAL AND MECHANICAL METAL FLANGES, METAL IS TO BE PRIMED
<br />WITH A D-41 PRIMER AND SET IN A FULL BED OF MATRX 201. METAL
<br />FLANGES ARE TO BE FLASHED THE SAME DAY THEY ARE INSTALLED WITH
<br />1 PLY OF INTEC/FLEX SMOOTH, 6" WIDER THAN
<br />THE FLANGE BEING FLASHED, SET IN A CONTINUOUS TROWELING OF MATRIX
<br />201.
<br />3.4.8 AT ALL LOCATIONS WHERE "BLEED -OUT' OF ASPHALT IS PRESENT, APPLY
<br />MINERAL GRANULES WHICH MATCH THE GRANULES OF THE CAP SHEET TO
<br />ACHIEVE 100% HIDING OF THE ASPHALT. APPLY GRANULES WHILE ASPHALT IS
<br />WARM ENOUGH TO ALLOW SOLID IMBEDMENT.
<br />3.4.9 ALLOW FOR EXPANSION OF RUNNING METAL FLASHING AND EDGE TRIM
<br />WHICH ADJOINS ROOFING.
<br />3.4.10 COUNTER FLASHINGS: COUNTER FLASHINGS, CAP FLASHINGS, EXPANSION
<br />JOINTS AND SIMILAR WORK SHALL BE COORDINATED WITH BUILT-UP ROOFING
<br />WORK.
<br />3.4.11 SEAMS: RIVET AND SOLDER ALL JOINTS IN GUTTERS. OTHER JOINTS
<br />SHALL BE FORMED FOR BACK SPLICE PLATES AS REQUIRED. SEAL WITH
<br />URETHANE SEALANT.
<br />1.1. PROTECTION OF ROOFING:
<br />3.5.1 UPON COMPLETION OF ROOFING WORK (INCLUDING ASSOCIATED WORK)
<br />INSTALLER SHALL ADVISE CONTRACTOR OF RECOMMENDED PROCEDURES FOR
<br />SURVEILLANCE AND PROTECTION OF
<br />ROOFING DURING REMAINDER OF CONSTRUCTION PERIOD.
<br />3.5.2 INSTALLER SHALL REPAIR OR REPLACE (AS REQUIRED) DETERIORATED OR
<br />DEFECTIVE WORK FOUND AT TIME OF FINAL INSPECTION. INSTALLER SHALL BE
<br />T R OFING WHICH
<br />ENGAGED BY CONTRACTOR TO REPAIR DAMAGES 0 0
<br />OCCURRED SUBSEQUENT TO ROOFING INSTALLATION AND PRIOR TO FINAL
<br />INSPECTION. REPAIR OR REPLACE THE ROOFING AND ASSOCIATED WORK TO A
<br />CONDITION FREE OF DAMAGE AND DETERIORATION AT TIME OF SUBSTANTIAL
<br />COMPLETION.
<br />1.2. CLEANING:
<br />3.6.1 REMOVE BITUMINOUS MARKINGS FROM FINISHED SURFACES IN AREAS
<br />WHERE FINISHED SURFACES ARE SOILED BY BITUMEN OR ANY OTHER
<br />SOURCE OF SOILING CAUSED BY WORK OF THIS SECTION. CONSULT
<br />MANUFACTURER FOR RECOMMENDED CLEANING METHODS AND MATERIALS AND
<br />CONFORM TO THEIR ADVICE.
<br />3.6.2 REMOVE FINISHED MATERIALS WHICH CANNOT SUCCESSFULLY BE
<br />CLEANED, AND REPLACE WITH NEW MATERIALS AT NO EXPENSE TO OWNER.
<br />END OF SECTION 07 51 00
<br />SECTION 07 60 00
<br />FLASHING AND SHEET METAL
<br />V02212011
<br />1.1. SCOPE: THIS SECTION INCLUDES ALL SHEET METAL WORK, E.G. OVERFLOW SCUPPERS,
<br />GUTTER, DOWNSPOUTS, GRAVEL STOP, PARAPET COPING CAP AND COUNTER FLASHING.
<br />1.2. RELATED SECTIONS INCLUDE THE FOLLOWING:
<br />1.2.1 SECTION 07 51 00 BITUMINOUS BUILT-UP ROOFING.
<br />1.2.2 SECTION 07 72 33 ROOF HATCHES.
<br />1.3. ALL PENETRATION SEALS ARE PART OF THE WORK OF THIS SECTION WITH THE
<br />FOLLOWING EXCEPTIONS:
<br />1.3.1 ALL AIR CONDITIONING AND VENTILATION DUCTS, HOOD AND DUCT COVERS IS
<br />WORK OF OTHER
<br />SECTIONS; FLASHING AND PENETRATION WATERPROOFING IS WORK OF THIS
<br />SECTION.
<br />1.3.2 ALL FLASHINGS FOR PENETRATIONS THROUGH ROOF MEMBRANE,
<br />INSULATION, FLASHING OR OTHER ITEMS MAKING UP THE ROOF ASSEMBLY
<br />ARE WORK OF THIS SECTION.
<br />1.3.3 ALL CURBS FOR HVAC EQUIPMENT, FANS, VENTS, AND FRESH AIR
<br />INTAKES WILL BE FURNISHED BY PUBLIX AND INSTALLED BY THE
<br />CONTRACTOR INSTALLING THIS EQUIPMENT.
<br />1.3.4 INSTALL ALL LEAD FLASHING UNDER THIS SECTION. SUPPLY LEAD
<br />FLASHING UNDER THIS SECTION OR OTHER SECTION AS APPROPRIATE FOR
<br />JOB CONDITIONS. COOPERATE WITH ALL TRADES.
<br />1.3.5 EQUIPMENT HOUSES LOCATED ON THE ROOF: ALL CURBS AND
<br />STRUCTURAL CONNECTIONS WILL BE PROVIDED AND SET WITH THE HOUSES.
<br />HOUSES WILL BE EQUIPPED WITH RECEIVERS FOR ROOFING WORK. PROVIDE
<br />FLASHING AND OTHER MEASURES TO RENDER THE INSTALLATIONS WATERTIGHT.
<br />1.4. PAINTING: ALL PVC VENT PENETRATIONS WILL REQUIRE PAINTING FOR UV PROTECTION.
<br />1.5. SUBMITTALS:
<br />1.5.1 LETTER OF INTENT (L01): INFORMATION FOR THIS SECTION WILL BE
<br />SUBMITTED AS PART OF THE L01 FOR SECTION 07 51 00 BITUMINOUS
<br />BUILT-UP ROOFING.
<br />1.5.2 SHOP DRAWINGS OF FLASHING DETAILS WILL ACCOMPANY THE SUBMITTAL
<br />PACKAGE FOR
<br />SECTION 07 51 00 BITUMINOUS BUILT-UP ROOFING.
<br />1.5.3 MATERIALS ON SITE: PROVIDE DOCUMENTS STATING THAT MATERIALS
<br />COMPLY WITH REQUIREMENTS, INCLUDING CERTIFICATES AND DELIVERY LOGS
<br />FOR BULK MATERIALS, AND RECORD ON FIELD TESTING FOR SOFTENING
<br />POINT, FLASH POINT, EVT, AND OTHER QUALITY CONTROL TESTING AS
<br />REQUIRED.
<br />1.6. QUALITY ASSURANCE
<br />1.6.1 INSTALLER (ROOFER):
<br />1.6.1.1 ALL WORK OF THIS SECTION SHALL BE BY THE APPROVED INSTALLER
<br />OF SECTION
<br />07 51 00 BITUMINOUS BUILT-UP ROOFING.
<br />1.6.1.2 PROVIDE PRODUCTS WHICH ARE ACCEPTABLE TO MANUFACTURER
<br />OF PRIMARY PRODUCTS.
<br />1.7. PRODUCT HANDLING
<br />1.7.1 WHEN MATERIALS ARE STORED OUTSIDE, THEY SHALL BE PLACED ON
<br />PLATFORMS THAT ARE RAISED OFF THE GROUND OR ROOF DECK, AND THEY
<br />SHALL BE COVERED WITH WATERPROOF COVERINGS. COVERINGS THAT ARE
<br />"BREATHABLE" (SUCH AS CANVAS) ARE PREFERRED.
<br />1.7.2 ROOFING MATERIALS SHALL BE DELIVERED TO THE JOB SITE JUST PRIOR
<br />TO ROOF INSTALLATION WHEN POSSIBLE OR STORED IN CLOSED VANS.
<br />1.7.3 ROOF LOADING: DO NOT STORE MATERIALS ON ROOF DECKS, NOR
<br />POSITION ROOFING INSTALLATION EQUIPMENT ON ROOF DECKS, IN
<br />CONCENTRATIONS EXCEEDING DESIGN LIVE LOADING.
<br />2. PRODUCTS
<br />2.1. SHEET METAL
<br />2.1.1 IN GENERAL, ALL SHEET METAL ITEMS SHALL BE FABRICATED FROM
<br />STAINLESS STEEL. USE PREFINISHED SHEET METAL ONLY WHERE REQUIRED
<br />TO MATCH OTHER WORK (FACADE) IN THE CENTER.
<br />2.1.2 STAINLESS STEEL
<br />2.1.2.1 FABRICATE FROM STAINLESS STEEL SHEET COMFORMING TO ASTM A666,
<br />TYPE
<br />302 OR 304; ANNEALED, 1 /16 HARD, OR 1 /8 HARD.
<br />2.1.2.2 USE GAUGE INDICATED BELOW OR AS PERMITTED BY SMACNA
<br />GAUGE RECOMMENDATIONS.
<br />2.1.2.3 FINISH: NO. 2B 'BRIGHT" COLD ROLLED FINISH.
<br />2.1.3 SHEET METAL ACCESSORY MATERIALS:
<br />2.1.3.1 WHERE AVAILABLE, USE PRE -ASSEMBLED, PRE -FLASHED
<br />ACCESSORIES FOR ALL ROOF PENETRATIONS, GRAVEL STOPS, GUTTERS,
<br />AND SUPPORT ASSEMBLIES.
<br />2.1.3.2 ACCEPTABLE MANUFACTURER:
<br />M-WELD DIVISION OF GAF/U.S. INTEC.
<br />2.1.3.3 ACCESSORIES
<br />2.1.3.3.1 EDGE METAL: GRAVELGUARD MB WITH PREFORMED OUTSIDE
<br />AND INSIDE CORNERS.
<br />2.1.3.3.2 VTR FLASHING, ANTENNA SUPPORT FLASHING: 6" ADJUSTABLE
<br />M- VENT WITH STAINLESS STEEL DRAW -BAND.
<br />2.1.3.3.3 FLUES: MANUFACTURER'S UL COMPLIANT INSULATED DOUBLE
<br />WALL FLUE FLASHING.
<br />2.1.3.3.4 PENETRATION SEALS: CHEMLINK "CHEMCURB" POLYESTER WITH
<br />1 PART POURABLE SEALER.
<br />2.1.4 ALUMINUM WALL PANELS:
<br />2.1.4.1 PROVIDE PREFINISHED 9/16" THICK .021 GA. "FABRIB" ALUMINUM
<br />WALL PANEL AS MANUFACTURED BY FABRAL.
<br />2.1.4.2 FASTEN ALUMINUM WALL PANELS TO 18 GA. 7/8" HAT
<br />CHANNELS W/ #12 SCREWS Q 8" O.C. HORIZONTAL AND 24" O.C.
<br />VERTICAL.
<br />2.1.5 SOLDER FOR SHEET METAL: EXCEPT AS OTHERWISE INDICATED OR
<br />RECOMMENDED BY METAL
<br />MANUFACTURER, PROVIDE -50/50 TIN/LEAD TYPE (ASTM-B32) FOR
<br />TINNING AND SOLDERING JOINTS.
<br />2.1.6 FASTENERS: SAME METAL AS FLASHING/SHEET METAL OR OTHER
<br />NON -CORROSIVE METAL AS RECOMMENDED BY MANUFACTURER.
<br />2.1.7 MINIMUM STAINLESS STEEL SHEET THICKNESS:
<br />DOWNSPOUTS 24 GA.
<br />GUTTERING 20 GA.
<br />FM ROLL OVER HANGERS 10 GA.
<br />GUTTER SPACE BRACKETS 14 GA.
<br />GRAVEL STOP 24 GA.
<br />COUNTER FLASHING 24 GA.
<br />RAIN COLLARS 24 GA.
<br />PARAPET COPINGS (<16" GIRTH 24 GA.
<br />PARAPET COPINGS (16" GIRTH AND ABOVE) 22 GA.
<br />OTHER SHEET METAL ITEMS: COMPLY WITH SMACNA RECOMMENDATIONS.
<br />2.2. FABRICATION OF SHEET METAL ACCESSORIES:
<br />2.2.1 SMACNA AND NRCA DETAILS: CONFORM WORK WITH DETAILS SHOWN
<br />AND WITH "ARCHITECTURAL SHEET METAL MANUAL" BY SMACNA. COMPLY
<br />WITH INSTALLATION DETAILS OF "ROOFING AND WATERPROOFING MANUAL" BY
<br />NRCA.
<br />2.2.2 PREFABRICATED UNITS AS INDICATED OR PROVIDE STANDARD
<br />MANUFACTURED UNITS COMPLYING WITH REQUIREMENTS; FABRICATE FROM
<br />SHEET METAL INDICATED.
<br />2.2.3 PROVIDE 4" WIDE FLANGES FOR SETTING ON BUILT-UP ROOFING
<br />MEMBRANE WITH CONCEALMENT BY COMPOSITION STRIPPING.
<br />2.2.4 GUTTERING AND DOWNSPOUTS ON EXTERIOR SIZED AS SHOWN ON
<br />DRAWINGS. SUPPORT GUTTERS AT MAXIMUM 36" O.C. AND DOWNSPOUTS AT
<br />FIVE (5) FEET ON CENTER. ALL JOINTS, END CAPS AND/OR MITERS SHALL
<br />BE RIVETED AND SOLDERED. NO CAULKING PERMITTED.
<br />2.2.5 PENETRATION SEALS FOR REFRIGERATION PENETRATIONS PER DETAIL.
<br />VERIFY PIPE SIZES PRIOR TO FABRICATION. PENETRATION SEALS FOR
<br />ELECTRICAL PENETRATIONS SHALL HAVE CONDUIT SOLDERED TO BASE OF
<br />PAN. USE WATER -TIGHT COUPLINGS.
<br />2.3. PAINT: THE FOLLOWING PAINTS WILL BE NEEDED FOR ALL PVC PENETRATIONS.
<br />2.3.1 PRIMER: SHERWIN WILLIAMS PREPRITE PROBLOCK LATEX SEALER.
<br />2.3.2 FINISH: SHERWIN WILLIAMS SUPERPAINT EXTERIOR LATEX SATIN (WHITE).
<br />3. EXECUTION
<br />3.1. GENERAL INSTALLATION REQUIREMENTS:
<br />3.1.1 SEQUENCING OF WORK:
<br />3.1.1.1 INSTALL ALL SHEET METAL EDGE TRIM, FLASHINGS, COPINGS,
<br />ETC. BEFORE INSTALLATION OF CAP SHEET. STRIP IN IMMEDIATELY.
<br />3.1.2 COORDINATE THE INSTALLATION OF INSULATION, ROOFING SHEETS,
<br />FLASHINGS, STRIPPING, COATINGS AND SURFACING, SO THAT INSULATION
<br />AND FELTS ARE NOT EXPOSED TO
<br />PRECIPITATION NOR EXPOSED OVERNIGHT.
<br />3.1.3 PROVIDE RAIN COLLARS AT ALL PITCH PANS, WHERE ROUND STOCK IS
<br />USED AS ROOF PENETRATION, AND OTHER LOCATIONS WHERE NEEDED. USE
<br />STAINLESS DRAW BANDS TO FORM MECHANICAL SEAL WITH COLLAR AND PIPE.
<br />3.2. PAINTING: PAINT ALL EXPOSED PVC VENTS (AFTER FLASHING AND BOOTS ARE IN PLACE)
<br />WITH ONE COAT OF SPECIFIED SEALER AND TWO COATS OF SPECIFIED FINISH.
<br />3.3. CLEANING:
<br />3.3.1 CLEAN EXPOSED METAL SURFACES OF SUBSTANCES THAT INTERFERE WITH
<br />UNIFORM OXIDATION AND WEATHERING.
<br />3.3.2 CLEAN AND NEUTRALIZE FLUX MATERIALS. CLEAN OFF EXCESS SOLDER AND
<br />SEALANTS.
<br />3.3.3 REMOVE TEMPORARY PROTECTIVE COVERINGS AND STRIPPABLE FILMS, IF
<br />ANY, AS SHEET METAL FLASHING AND TRIM ARE INSTALLED. UPON
<br />COMPLETION OF INSTALLATION, CLEAN FINISHED SURFACES, INCLUDING
<br />REMOVING UNUSED FASTENERS, METAL FILINGS, POP RIVET SEAMS AND
<br />PIECES OF FLASHING. MAINTAIN IN A CLEAN CONDITION DURING
<br />CONSTRUCTION.
<br />3.3.4 REPLACE SHEET METAL FLASHING AND TRIM THAT HAVE BEEN DAMAGED
<br />OR HAVE DETERIORATED BEYOND SUCCESSFUL REPAIR BY FINISH TOUCHUP
<br />OR SIMILAR MINOR REPAIR PROCEDURES.
<br />END OF SECTION 07 60 00
<br />SECTION 07 72 33
<br />ROOF HATCHES
<br />V09252015
<br />1.1. SCOPE: THIS SECTION INCLUDES INFORMATION PERTAINING TO ROOF HATCHES.
<br />1.2. RELATED SECTIONS INCLUDE THE FOLLOWING:
<br />1.2.1 SECTION 07 51 00 BITUMINOUS BUILT-UP ROOFING.
<br />1.2.2 SECTION 07 60 00 FLASHING AND SHEET METAL.
<br />1.3. SUBMITTALS:
<br />1.3.1 LETTER OF INTENT (L01): INDICATE PRODUCT SELECTION ON L01 FOR SECTION
<br />07 51 00 BITUMINOUS BUILT-UP ROOFING.
<br />1.4. QUALITY ASSURANCE
<br />1.4.1 INSTALLER (ROOFER):
<br />1.4.1.1 INSTALLER SAME BE SAME AS APPROVED FOR WORK OF SECTION
<br />07 51 00 BITUMINOUS BUILT-UP ROOFING.
<br />1.5. DELIVERY, HANDLING AND STORAGE
<br />1.5.1 PACK, HANDLE AND SHIP PROPERLY LABELED IN HEAVY-DUTY
<br />PACKAGING TO PREVENT DAMAGE.
<br />2. PRODUCTS
<br />2.1. ROOF HATCH: PROVIDE ALUMINUM ROOF HATCH WITH SAFETY POLE:
<br />2.1.1 BILCO #S-50 ALUMINUM ROOF HATCH
<br />2.1.2 BADCOCK-DAVIS MODEL BRHPA36X3OS1T. FOR HIGH VELOCITY WIND
<br />ZONES USE MODEL BRHZA36X30S1T
<br />2.2. EXECUTION
<br />2.3. INSTALLATION:
<br />2.3.1 INSTALL ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. INSTALL
<br />TO RESIST EXPOSURE TO WEATHER WITHOUT FAILING, RATTLING AND LEAKING.
<br />2.3.2 SAFETY POLE SHOULD BE INSTALLED TO FAR RIGHT OR FAR LEFT SIDE
<br />OF OPENING. DO NOT INSTALL SAFETY POLE CENTERED WITH LADDER AS
<br />APPROVED.
<br />2.3.3 CHECK ROOF HATCH FOR PROPER OPERATION. ADJUST OPERATING MECHANISM
<br />AS REQUIRED. CLEAN AND LUBRICATE JOINTS AND HARDWARE.
<br />2.4. TOUCH-UP:
<br />2.4.1 TOUCH UP FACTORY -PRIMED SURFACES WITH COMPATIBLE PRIMER
<br />READY FOR FIELD PAINTING IN ACCORDANCE WITH SECTION 09 91 00
<br />PAINTS.
<br />END OF SECTION 07 72 33
<br />SECTION 07 92 00
<br />JOINT SEALANTS
<br />V01062015
<br />1.1. SCOPE: THIS SECTION COVERS SEALANTS FOR USE IN ALL LOCATIONS EXCEPT GLAZING.
<br />1.2. SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL PROCEDURES.
<br />1.3. QUALITY ASSURANCE - SEALANT COMPATIBILITY AND ADHESION TESTING: USE SEALANT
<br />MANUFACTURER'S STANDARD TEST METHODS TO DETERMINE WHETHER PRIMING AND
<br />OTHER SPECIFIC JOINT PREPARATION TECHNIQUES ARE REQUIRED TO OBTAIN RAPID,
<br />OPTIMUM ADHESION OF JOINT SEALANTS TO JOINT SUBSTRATES.
<br />2. PRODUCTS
<br />2.1. MATERIALS, GENERAL
<br />2.1.1 COMPATIBILITY: PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER
<br />RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND
<br />WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND
<br />APPLICATION, AS DEMONSTRATED BY SEALANT MANUFACTURER BASED
<br />ON TESTING AND FIELD EXPERIENCE.
<br />2.1.2 COLORS OF EXPOSED JOINT SEALANTS: MATCH COLOR OF
<br />MATERIALS BEING JOINED IF POSSIBLE. WHERE NOT POSSIBLE,
<br />USE COLOR SELECTED TO PROVIDE AN UNOBTRUSIVE FINISHED
<br />SURFACE.
<br />2.2. ELASTOMERIC JOINT SEALANTS
<br />2.2.1 USE SINGLE -COMPONENT URETHANE SEALANTS. IF UNUSUAL
<br />CONDITIONS OR TYPE OF WORK TO BE ACCOMPLISHED MAKES THE
<br />USE OF MULTI -COMPONENT SEALANTS DESIRABLE, CONTACT PUBLIX
<br />ARCHITECT.
<br />2.2.2 ELASTOMERIC SEALANTS, GENERAL: ASTM C 920.
<br />2.2.3 SEALANTS FOR CONTACT WITH FOOD: COMPLY WITH 21 CFR
<br />177.2600.
<br />2.2.4 SINGLE -COMPONENT NONSAG URETHANE SEALANT (GUN -GRADE):
<br />2.2.4.1 PRODUCTS:
<br />BOSTIK INC.; CHEM-CALK 500. TREMCO;
<br />DYMONIC FC
<br />PECORA CORPORATION; DYNATROL I.
<br />POLYMERIC SYSTEMS, INC.; PSI-901.
<br />2.2.4.2 TYPE AND GRADE: S (SINGLE COMPONENT) AND NS (NONSAG).
<br />2.2.4.3 CLASS: 25.
<br />2.2.4.4 EXPOSURE: USE T (TRAFFIC) OR NT (NONTRAFFIC).
<br />2.2.4.5 SUBSTRATES: USES M, A, AND, AS APPLICABLE TO JOINT
<br />SUBSTRATES INDICATED, 0.
<br />2.2.5 SINGLE -COMPONENT POURABLE URETHANE SEALANT:
<br />2.2.5.1 PRODUCTS:
<br />BOSTIK INC.; CHEM-CALK 950.
<br />MAMECO INTERNATIONAL; VULKEM 455 SL.
<br />PECORA CORPORATION; NR-201.
<br />POLYMERIC SYSTEMS, INC.; FLEXIPRENE PSI-951.
<br />2.2.5.2 TYPE AND GRADE: S (SINGLE COMPONENT) AND P (POURABLE)
<br />2.2.5.3 CLASS: 25.
<br />2.2.5.4 EXPOSURE: USE T (TRAFFIC) AND NT (NONTRAFFIC).
<br />2.2.5.5 SUBSTRATES: USES M, A, AND, AS APPLICABLE TO JOINT
<br />SUBSTRATES INDICATED, 0.
<br />2.3. LATEX JOINT SEALANTS: ASTM C 834. USE WHERE SEALANT WILL BE PAINTED, AND
<br />ONLY WHERE JOINT MOVEMENT CANNOT OCCUR.
<br />2.3.1 PRODUCTS:
<br />BOSTIK INC.; CHEM-CALK 600. PECORA
<br />CORPORATION; AC-20. POLYMERIC SYSTEMS,
<br />INC.; PSI-701.
<br />2.4. JOINT -SEALANT BACKING
<br />2.4.1 GENERAL: PROVIDE SEALANT BACKINGS OF MATERIAL AND TYPE
<br />THAT ARE NONSTAINING; ARE COMPATIBLE WITH JOINT SUBSTRATES,
<br />SEALANTS, PRIMERS, AND OTHER JOINT FILLERS; AND ARE APPROVED
<br />FOR APPLICATIONS INDICATED BY SEALANT MANUFACTURER BASED ON
<br />FIELD EXPERIENCE AND LABORATORY TESTING.
<br />2.4.2 CYLINDRICAL SEALANT BACKINGS: ASTM C 1330, OF SIZE AND
<br />DENSITY TO CONTROL SEALANT DEPTH AND OTHERWISE
<br />CONTRIBUTE TO PRODUCING OPTIMUM SEALANT PERFORMANCE.
<br />TYPE: 0 (OPEN -CELL MATERIAL), OR B (BICELLULAR MATERIAL
<br />WITH A SURFACE SKIN).
<br />2.4.3 ELASTOMERIC TUBING SEALANT BACKINGS: NEOPRENE, BUTYL,
<br />EPDM, OR SILICONE TUBING COMPLYING WITH ASTM D 1056,
<br />NONABSORBENT TO WATER AND GAS, AND CAPABLE OF REMAINING
<br />RESILIENT AT TEMPERATURES DOWN TO MINUS 26 F (MINUS 32
<br />C). PROVIDE PRODUCTS WITH LOW COMPRESSION SET AND OF SIZE
<br />AND SHAPE TO PROVIDE A SECONDARY SEAL, TO CONTROL SEALANT
<br />DEPTH, AND OTHERWISE CONTRIBUTE TO OPTIMUM SEALANT
<br />PERFORMANCE.
<br />2.4.4 BOND -BREAKER TAPE: POLYETHYLENE TAPE OR OTHER PLASTIC
<br />TAPE RECOMMENDED BY SEALANT MANUFACTURER FOR PREVENTING
<br />SEALANT FROM ADHERING TO RIGID, INFLEXIBLE JOINT -FILLER
<br />MATERIALS OR JOINT SURFACES AT BACK OF JOINT WHERE SUCH
<br />ADHESION WOULD RESULT IN SEALANT FAILURE. PROVIDE
<br />SELF-ADHESIVE TAPE WHERE APPLICABLE.
<br />2.5. MISCELLANEOUS MATERIALS
<br />2.5.1 PRIMER: MATERIAL RECOMMENDED BY JOINT SEALANT
<br />MANUFACTURER WHERE REQUIRED FOR ADHESION OF SEALANT TO
<br />JOINT SUBSTRATES INDICATED, AS DETERMINED FROM
<br />PRECONSTRUCTION JOINT -SEALANT -SUBSTRATE TESTS AND FIELD
<br />TESTS.
<br />2.5.2 CLEANERS FOR NONPOROUS SURFACES: CHEMICAL CLEANERS
<br />ACCEPTABLE TO MANUFACTURERS OF SEALANTS AND SEALANT
<br />BACKING MATERIALS, FREE OF OILY RESIDUES OR OTHER
<br />SUBSTANCES CAPABLE OF STAINING OR HARMING JOINT SUBSTRATES
<br />AND ADJACENT NONPOROUS SURFACES IN ANY WAY, AND
<br />FORMULATED TO PROMOTE OPTIMUM ADHESION OF SEALANTS WITH
<br />JOINT SUBSTRATES.
<br />2.5.3 MASKING TAPE: NONSTAINING, NONABSORBENT MATERIAL
<br />COMPATIBLE WITH JOINT SEALANTS AND SURFACES ADJACENT TO
<br />JOINTS.
<br />3. EXECUTION
<br />3.1 . INSTALLATION
<br />3.1.1 SURFACE CLEANING OF JOINTS: CLEAN OUT JOINTS IMMEDIATELY
<br />BEFORE INSTALLING JOINT SEALANTS.
<br />3.1.1.1 REMOVE FOREIGN MATERIAL FROM JOINT SUBSTRATES
<br />THAT COULD INTERFERE WITH ADHESION OF JOINT SEALANT.
<br />3.1.1.2 CLEAN POROUS JOINT SUBSTRATE SURFACES BY
<br />BRUSHING, GRINDING, BLAST CLEANING, MECHANICAL ABRADING,
<br />OR A COMBINATION OF THESE METHODS TO PRODUCE A CLEAN,
<br />SOUND SUBSTRATE CAPABLE OF DEVELOPING OPTIMUM BOND
<br />WITH JOINT SEALANTS. REMOVE LOOSE PARTICLES REMAINING
<br />FROM ABOVE CLEANING OPERATIONS BY VACUUMING OR
<br />BLOWING OUT JOINTS WITH OIL -FREE COMPRESSED AIR.
<br />3.1.1.3 REMOVE LAITANCE AND FORM -RELEASE AGENTS FROM
<br />CONCRETE.
<br />3.1.1.4 CLEAN NONPOROUS SURFACES WITH CHEMICAL CLEANERS
<br />OR OTHER MEANS THAT DO NOT STAIN, HARM SUBSTRATES, OR
<br />LEAVE RESIDUES COULD INTERFERE WITH ADHESION OF JOINT
<br />SEALANTS.
<br />3.1.2 JOINT PRIMING: PRIME JOINT SUBSTRATES WHERE
<br />RECOMMENDED IN WRITING BY JOINT SEALANT MANUFACTURER,
<br />BASED ON PRECONSTRUCTION JOINT -SEALANT -SUBSTRATE TESTS
<br />OR PRIOR EXPERIENCE. CONFINE PRIMERS TO AREAS OF
<br />JOINT -SEALANT BOND; DO NOT ALLOW SPILLAGE OR MIGRATION
<br />ONTO ADJOINING SURFACES.
<br />3.1.3 MASKING TAPE: USE MASKING TAPE WHERE REQUIRED TO
<br />PREVENT CONTACT OF SEALANT WITH ADJOINING SURFACES THAT
<br />OTHERWISE WOULD BE PERMANENTLY STAINED OR DAMAGED BY
<br />SUCH CONTACT OR BY CLEANING METHODS REQUIRED TO REMOVE
<br />SEALANT SMEARS. REMOVE TAPE IMMEDIATELY AFTER TOOLING
<br />WITHOUT DISTURBING JOINT SEAL.
<br />3.1.4 SEALANT INSTALLATION: COMPLY WITH RECOMMENDATION IN ASTM
<br />C 1193 FOR USE OF JOINT SEALANTS AS APPLICABLE TO
<br />MATERIALS, APPLICATIONS, AND CONDITIONS INDICATED.
<br />3.1.5 INSTALL SEALANT BACKINGS TO SUPPORT SEALANTS DURING
<br />APPLICATION AND AT POSITION REQUIRED TO PRODUCE OPTIMUM
<br />SEALANT MOVEMENT CAPABILITY.
<br />3.1.5.1 DO NOT LEAVE GAPS BETWEEN ENDS OF SEALANT BACKINGS.
<br />3.1.5.2 DO NOT STRETCH, TWIST, PUNCTURE, OR TEAR SEALANT
<br />BACKINGS.
<br />3.1.5.3 REMOVE ABSORBENT SEALANT BACKINGS THAT HAVE
<br />BECOME WET BEFORE SEALANT APPLICATION AND REPLACE
<br />THEM WITH DRY MATERIALS.
<br />3.1.6 INSTALL BOND -BREAKER TAPE BEHIND SEALANTS WHERE
<br />SEALANT BACKINGS ARE NOT USED BETWEEN SEALANTS AND BACK
<br />OF JOINTS.
<br />3.1.7 PLACE SEALANTS SO THEY DIRECTLY CONTACT AND FULLY
<br />WET JOINT SUBSTRATES.
<br />3.1.7.1 COMPLETELY FILL RECESSES PROVIDED FOR EACH JOINT
<br />CONFIGURATION.
<br />3.1.7.2 PRODUCE UNIFORM, CROSS -SECTIONAL SHAPES AND
<br />DEPTHS THAT ALLOW OPTIMUM SEALANT MOVEMENT CAPABILITY.
<br />3.1.8 TOOLING OF NONSAG SEALANTS: IMMEDIATELY AFTER SEALANT
<br />APPLICATION AND BEFORE SKINNING OR CURING BEGINS, TOOL
<br />SEALANTS TO FORM SMOOTH, UNIFORM BEADS, TO ELIMINATE AIR
<br />POCKETS, AND TO ENSURE CONTACT AND ADHESION OF SEALANT
<br />WITH SIDE OF JOINT.
<br />3.1.8.1 REMOVE EXCESS SEALANTS FROM SURFACES ADJACENT TO
<br />JOINT.
<br />3.1.8.2 USE TOOLING AGENTS THAT ARE APPROVED BY SEALANT
<br />MANUFACTURER AND THAT
<br />DO NOT DISCOLOR SEALANTS OR ADJACENT SURFACES.
<br />3.1.8.3 JOINT CONFIGURATION: CONCAVE JOINT CONFIGURATION PER
<br />FIGURE 5A IN
<br />ASTM C 1193, UNLESS OTHERWISE INDICATED.
<br />END OF SECTION 07 92 00
<br />WILL BE ALLOWED.
<br />2. PRODUCTS
<br />2.1. STEEL DOORS AND FRAMES:
<br />2.1.1 TYPICAL DOORS: PROVIDE DOORS HAVING 18 GA. STEEL FACE SHEETS
<br />FOR INTERIOR APPLICATIONS, 16 OR 14 GA. GALVANIZED FOR EXTERIOR
<br />APPLICATIONS. PRIME PAINT ALL SURFACES.
<br />2.1.2 EXTERIOR APPLICATIONS MUST HAVE A POLYURETHANE CORE INSULATION WITH
<br />A MINIMUM
<br />R FACTOR OF 4.75
<br />2.1.3 METAL FRAMES:
<br />2.1.3.1 PROVIDE 16 GA. FRAMES IN SIZES AND STYLES SHOWN ON THE
<br />DRAWINGS, ALL WELDED, GALVANIZED FOR EXTERIOR APPLICATIONS, WITH
<br />MINIMUM THREE ANCHORS PER JAMB OF THE TYPE REQUIRED FOR WALL
<br />CONSTRUCTION. PRIME PAINT ALL SURFACES.
<br />2.1.3.2 PREPARE FRAMES TO RECEIVE HARDWARE AS DESCRIBED BY ANSI/SDI
<br />100.
<br />REINFORCE HINGE, LATCH, AND DEADBOLT LOCATIONS AS REQUIRED.
<br />2.1.3.3 PROVIDE FOR DEADBOLT INSTALLATION AT JAMB FOR UPPER LEAF OF
<br />DUTCH DOOR AT
<br />PHARMACY.
<br />2.2. LABELED ASSEMBLIES:
<br />2.2.1 FIRE DOORS: COMPLY WITH REQUIREMENTS ABOVE. ADDITIONALLY, USE
<br />TESTED AND APPROVED FIRE RESISTANT CORE. ATTACH A PERMANENT LABEL
<br />SHOWING COMPLIANCE WITH THE REQUIRED LABEL.
<br />2.2.2 FRAMES: COMPLY WITH REQUIREMENTS ABOVE.
<br />2.3. ACCESSORIES: PROVIDE THREE SILENCERS PER DOOR; AT MASONRY WALLS, PROVIDE 26
<br />GA. MORTAR BOXES TO PROTECT HARDWARE CUTOUTS. LOUVERS SHALL BE
<br />SIGHT -PROOF TYPE, 14 GA. STEEL, PRIME PAINTED, GALVANIZED AT EXTERIOR. GLAZING
<br />STOPS SHALL BE 20 GA. FLUSH TYPE, PRIME
<br />PAINTED, GALVANIZED AT EXTERIOR.
<br />2.4. MANUFACTURERS:
<br />CECO
<br />CURRIES
<br />3. EXECUTION
<br />3.1. FRAME INSTALLATION: SET FRAMES PLUMB, LEVEL AND TRUE. USE WALL ANCHORS
<br />APPROPRIATE FOR EACH TYPE OF ENCLOSING WALL.
<br />3.2. DOOR INSTALLATION: HANG DOORS TO PROVIDE SMOOTH OPERATION WITH TIGHT
<br />CLOSURE. INSTALL GLAZING AND SILENCERS AFTER DOORS AND FRAMES RECEIVE FINAL
<br />PAINT APPLICATION.
<br />3.3. FIRE RATED ASSEMBLIES: SET FRAMES AND HANG DOORS IN COMPLIANCE WITH NFPA
<br />80.
<br />END OF SECTION 08 11 00
<br />SECTION 08 14 00
<br />WOOD DOORS
<br />V03172017
<br />1.1. DESCRIPTION OF THE WORK: THIS SECTION COVERS ALL WOOD DOORS AND WOOD
<br />DOORS WITH PLASTIC LAMINATE FACES, INCLUDING FABRICATION AND ERECTION.
<br />1.2. SUBMITTALS: COMPLETED L01, LIST OF MATERIALS PROPOSED FOR USE,
<br />MANUFACTURER'S SPECIFICATIONS, SHOP DRAWINGS AS REQUIRED TO DESCRIBE
<br />INTENDED ASSEMBLIES, AND OTHER PERTINENT DETAILS OF PROPOSED INSTALLATION
<br />1.3. QUALITY ASSURANCE: PROVIDE PRODUCTS OF ONE MANUFACTURER THROUGHOUT THE
<br />PROJECT.
<br />COMPLY WITH AW1 1300 FOR MANUFACTURER AND INSTALLATION.
<br />1.4. MANUFACTURER'S RECOMMENDATIONS FOR STORAGE, HANDLING, AND PROTECTION SHALL
<br />BE FOLLOWED EXACTLY.
<br />1.5. NO SUBSTITUTIONS WILL BE ALLOWED.
<br />2. PRODUCTS
<br />2.1. WOOD DOORS: PROVIDE WOOD DOORS WITH PARTICLE BOARD CORE COMPLYING WITH
<br />ANSI A208.ILD2, PAINT GRADE.
<br />2.2. FACTORY PREP ALL DOORS TO RECEIVE HARDWARE SPECIFIED.
<br />2.3. VIEWLITES: ALL VIEWLITES SHALL BE CLEAR, 1 /4" TEMPERED GLASS, UNLESS OTHERWISE
<br />SPECIFIED. MEASURING 6" X 30" OR 18" X 58" (SEE DOOR ELEVATIONS).
<br />2.4. VENEER: PROVIDE ALL INTERIOR WOOD DOORS WITH .125 INCH THICK DECORATIVE
<br />HIGH-PRESSURE LAMINATE BOTH SIDES. SEE DOOR SCHEDULE FOR LAMINATE COLORS.
<br />2.5. ACCESSORIES: PROVIDE THREE SILENCERS PER DOOR. LOUVERS SHALL BE
<br />SIGHT -PROOF TYPE FABRICATED FROM 14 GA. STEEL, PRIME PAINTED. GLAZING STOPS
<br />AND FRAMES SHALL BE 20 GA. STEEL, PRIME PAINTED.
<br />2.6. MANUFACTURERS:
<br />VT INDUSTRIES DOORMERICA MARSHFIELD
<br />3. EXECUTION
<br />3.1. DOOR INSTALLATION: HANG DOORS TO PROVIDE SMOOTH OPERATION WITH TIGHT
<br />CLOSURE. INSTALL GLAZING AND SILENCERS AFTER DOORS AND FRAMES RECEIVE FINAL
<br />PAINT APPLICATION.
<br />END OF SECTION 08 14 00
<br />SECTION 08 17 05
<br />SIDE FOLDING GRILLES
<br />V03172017
<br />1.1.1 SECTION INCLUDES: MANUAL SIDE -FOLDING ALUMINUM SECURITY GRILLES
<br />WITH STORAGE POCKET.
<br />1.2. SUBMITTALS:
<br />1.2.1 REFERENCE SECTION 01 33 00 SUBMITTAL PROCEDURES; SUBMIT FOLLOWING
<br />ITEMS:
<br />1.2.1.1 PRODUCT DATA: INCLUDE PUBLISHED DATA AND SPECIFIC DATA
<br />PREPARED FOR THIS PROJECT.
<br />1.2.1.2 SHOP DRAWINGS: INCLUDE DETAILED PLANS, ELEVATIONS, REQUIRED
<br />CLEARANCES AND ACCESSORIES.
<br />1.2.1.3 INSTALLATION INSTRUCTIONS.
<br />1.2.1.4 QUALITY ASSURANCE REQUIREMENTS:
<br />1.2.1.4.1 MANUFACTURER QUALIFICATIONS.
<br />1.2.1.4.2 INSTALLER QUALIFICATIONS.
<br />1.2.1.4.3 CERTIFICATES.
<br />1.3. QUALITY ASSURANCE:
<br />1.3.1 MANUFACTURER QUALIFICATIONS: MINIMUM OF THREE YEARS
<br />EXPERIENCE IN THE FABRICATION AND INSTALLATION OF SIDE FOLDING
<br />SECURITY GRILLES.
<br />1.3.2 INSTALLER QUALIFICATIONS: AUTHORIZED REPRESENTATIVE OF THE
<br />MANUFACTURER.
<br />1.3.3 CERTIFICATE STATING THAT MATERIALS AND FINISHES COMPLY WITH
<br />SPECIFICATIONS.
<br />1.3.4 SINGLE SOURCE RESPONSIBILITY: PROVIDE GRILLES, STORAGE POCKET,
<br />TRACK AND RELATED PRIMARY COMPONENTS FROM ONE MANUFACTURER FOR
<br />EACH TYPE OF GRILLE. PROVIDE SECONDARY COMPONENTS FROM SOURCE
<br />ACCEPTABLE TO MANUFACTURER OF PRIMARY COMPONENTS
<br />1.3.5 PRE -INSTALLATION CONFERENCE: SCHEDULE AND CONVENE A
<br />PRE -INSTALLATION CONFERENCE JUST PRIOR TO COMMENCEMENT OF FIELD
<br />OPERATIONS TO ESTABLISH PROCEDURES TO MAINTAIN OPTIMUM WORKING
<br />CONDITIONS AND TO COORDINATE THIS WORK WITH RELATED AND ADJACENT
<br />WORK.
<br />1.4. DELIVERY, STORAGE AND HANDLING
<br />1.4.1 REFERENCE SECTION 01 66 00 PRODUCT STORAGE AND HANDLING
<br />REQUIREMENTS.
<br />1.4.2 DELIVER MATERIALS IN LABELED PROTECTIVE PACKAGES. STORE AND
<br />HANDLE IN COMPLIANCE WITH MANUFACTURER'S INSTRUCTIONS.
<br />2. PRODUCTS
<br />2.1. MANUFACTURERS:
<br />DYNAMIC CLOSURES
<br />TELEPHONE: 1-800-663-4599; FAX: 1-800-205-6665
<br />E-MAIL: INFO@DYNAMICCLOSURES.COM
<br />MOBILFLEX, INC. (NOT AVAILABLE FOR 28 PROTOTYPE)
<br />TELEPHONE: 1-800-216-3539; FAX: 1-800-254-3539
<br />CONTACT NAME: PIERRE-LUC ROBERT
<br />SUBSTITUTIONS: REFERENCE SECTION 01 25 00 PRODUCT SUBSTITUTION
<br />PROCEDURES.
<br />2.2. MODELS AND MATERIALS:
<br />2.2.1 MODELS: EZ CLOSURE BP (DYNAMIC CLOSURES), POCKET SCREEN (METRO
<br />DOOR) OR AEROFLEX (MOBILFLEX).
<br />2.2.2 CURTAIN:
<br />2.2.2.1 PANELS: TOP AND BOTTOM OF ALUMINUM AND OF SIZES SPECIFIED
<br />BY MANUFACTURERS. MAIN PORTION OF PANELS 2" WIDE OF
<br />PERFORATED ALUMINUM. PANELS ARE LINKED TOGETHER BY A
<br />CONTINUOUS ALUMINUM HINGE (3 1/2" ON CENTER).
<br />2.2.2.2 CURTAIN SHALL BE FULLY ASSEMBLED AND INSTALLED IN POCKET
<br />BY RESPECTIVE MANUFACTURER.
<br />2.2.3 CURTAIN HEIGHT: REFERENCE DRAWINGS.
<br />2.2.4 FINISH -EXPOSED ALUMINUM PARTS CLEAR ANODIZED; HIEP IS A "CLEAR
<br />ANODIZED" COLOR.
<br />2.2.5 LOCKING POSTS: REFERENCE MANUFACTURER'S INSTALLATION DRAWING.
<br />DROPBOLTS SHALL BE INSTALLED EVERY 14-16 PANELS AND ALL LOCK
<br />MECHANISMS SHALL FACE TO THE OUTSIDE OF THE PHARMACY.
<br />2.2.6 LOCKS: THE LOCK TYPE ON GATE SHALL BE SPIC (SMALL FORMAT
<br />INTERCHANGEABLE
<br />CORE) FOR ALL LOCKING POS T.
<br />2.2.7 OVERHEAD TRACK: EXTRUDED ALUMINUM, OF SIZE SPECIFIED BY
<br />MANUFACTURER, WITH CONTINUOUS EXTRUDED PROFILE SEAMED TOGETHER
<br />BY ALIGNMENT BARS AND TRACK PINS. TRACK TO BE SECURED TO A
<br />HEADER THAT WILL CARRY WEIGHT OF COMPLETE CURTAIN. THE WALL
<br />CHANNEL SHALL BE FASTENED TO THE OPPOSITE WALL PROPERLY BLOCK
<br />AND CONSTRUCTED BY OTHERS. HEADER THAT SUPPORTS THE TRACK IS
<br />CONSTRUCTED BY OTHERS.
<br />2.2.8 POCKET: WELDED 1 /2" TUBULAR STEEL FRAME THAT IS 6" EXTERIOR
<br />SUITABLE FOR COMMERCIAL CONSTRUCTION OF 6" STUD WALLS. INTERIOR
<br />CLEAR OPENING WIDTH OF 5" BY HEIGHT OF CURTAIN REQUIRED. POCKET IS
<br />ADJUSTABLE TO BE RAISED OR LOWERED UP TO AN INCH. FRONT CORNER
<br />ANGLES FLAPS TO COVER POCKET OPENING WITH PIANO HINGES. ANGLES
<br />ALSO ACCEPT 1/2" OR 5/8" SHEETROCK.
<br />2.2.9 OPERATION:
<br />2.2.9.1 MANUAL PULL OPERATION.
<br />2.2.9.2 PROVIDE ATTACHED PULL STRAPS ON GRILLES OVER 9'O" (2745
<br />MM) IN HEIGHT AND ALL COUNTER HEIGHT GRILLES.
<br />3. EXECUTION
<br />3.1. EXAMINATION:
<br />3.1.1 EXAMINE SUPPORTS AND OTHER CONDITIONS UNDER WHICH GRILLES ARE TO
<br />BE INSTALLED.
<br />3.1.2 COORDINATE WITH RESPONSIBLE ENTITY TO CORRECT UNSATISFACTORY
<br />CONDITIONS AND DO NOT PROCEED WITH INSTALLATION UNTIL CONDITIONS
<br />ARE CORRECTED.
<br />3.2. INSTALLATION:
<br />3.2.1 FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND APPROVED SHOP
<br />DRAWINGS.
<br />3.3. ADJUSTING AND CLEANING:
<br />3.3.1 TEST OPERATION OF GRILLE AND ADJUST AS NECESSARY TO PROVIDE
<br />SMOOTH AND PROPER OPERATION.
<br />3.3.2 CLEAN EXPOSED SURFACES USING MANUFACTURERS RECOMMENDED CLEANSER.
<br />3.4. DEMONSTRATION:
<br />3.4.1 INSTRUCT OWNER'S PERSONNEL IN PROPER OPERATING AND
<br />MAINTENANCE PROCEDURES.
<br />END OF SECTION 08 17 05
<br />PROVIDE NO LESS THAN A R-VALUE OF 6.0.
<br />2.1.1.1 THE FINISH OF THE DOOR CURTAIN SHALL CONSIST OF THE
<br />FOLLOWING.
<br />2.1.1.1.1 HOT DIPPED GALVANIZED G-90 COATING CONSISTENT
<br />WITH ASTM A-525.
<br />2.1.1.1.2 BONDERIZED COATING FOR PRIME COAT ADHESION.
<br />2.1.1.1.3 CORROSION INHIBITING PRIMER- .2 MILS PER SIDE.
<br />2.1.1.1.4 THERMO- SETTING POLYESTER TOP COAT WITH A
<br />MINIMUM THICKNESS OF .6 MILS EACH SIDE.
<br />2.1.1.1.5 SPECIAL REQUIREMENT - COASTAL AREAS: WHERE
<br />EXTERIOR MOUNTED COILING DOORS ARE REQUIRED AT THE
<br />AUTOMATIC ENTRANCE DOORS, PAINT ALL EXPOSED METAL
<br />R ARY FA ADE COLOR. SEE SECTION
<br />SURFACES, MATCHING THE P IM C
<br />09 91 00 - PAINTS REGARDING REQUIREMENTS FOR PAINTING
<br />EXP SED EXTERIOR METAL SURFACES.
<br />0
<br />R HA L CONSIST OF TWO 1 8" ANGLES
<br />2.1.1.2 THE BOTTOM BA S L /
<br />MECHANICALLY JOINED TOGETHER WITH A 1" DIAMETER VINYL COVERED
<br />FOAM EDGE ASTRAGAL CONTINUOUS ALONG THE BOTTOM. THE FINISH ON
<br />THE BOTTOM BAR SHALL BE ONE COAT OF RUST INHIBITING PRIME
<br />PAINT.
<br />2.1.1.3 GUIDES SHALL CONSIST OF STEEL ANGLES BOLTED TOGETHER TO
<br />FORM A CHANNEL FOR THE CURTAIN TO TRAVEL. VINYL SNAP -ON
<br />WEATHERSTRIPPING SHALL BE FURNISHED CONTINUOUSLY ALONG THE
<br />EXTERIOR LEG OF EACH GUIDE. GUIDE ANGLES SHALL BE COATED WITH
<br />ONE COAT OF RUST INHIBITING PRIME PAINT.
<br />2.1.1.4 THE BRACKETS SHALL BE OF STEEL NOT LESS THAN 1/4" THICK
<br />AND FINISHED WITH ONE COAT OF RUST INHIBITING PRIME PAINT.
<br />2.1.1.5 THE HOOD SHALL BE FABRICATED FROM 24 GAUGE GALVANIZED
<br />STEEL AND SHALL BE FORMED TO FIT THE CURVATURE OF THE
<br />BRACKETS. THE HOOD SHALL BE CORRUGATED EVERY 1" ALONG THE
<br />CURVATURE FOR THE ENTIRE LENGTH OF THE HOOD. THE HOOD SHALL
<br />CONTAIN A WATERPROOF CANVAS BAFFLE TO CONTROL AIR
<br />INFILTRATION AND SHALL BE GASKET-ED AT THE WALL TO PREVENT PEST
<br />INFILTRATION.
<br />2.1.1.5.1 SPECIAL REQUIREMENT - COASTAL AREAS: WHERE
<br />EXTERIOR MOUNTED COILING DOORS ARE REQUIRED AT THE
<br />AUTOMATIC ENTRANCE DOORS, THE HOOD WILL BE RECTANGULAR IN
<br />FORM. HOOD MUST ALSO BE FABRICATED TO ENCLOSE ALL GEARS
<br />AND MECHANISMS.
<br />2.1.1.5.2 SPECIAL REQUIREMENT - COASTAL AREAS: WHERE
<br />EXTERIOR MOUNTED COILING DOORS ARE REQUIRED AT THE
<br />AUTOMATIC ENTRANCE DOORS, THE ROLLING DOOR SHALL BE MADE
<br />OF 22 GAUGE INTERLOCKING SLATS, NON -INSULATED. THE DOOR
<br />MUST BY BE OPERATED BY A REMOVABLE HAND CRANK. NO CHAIN
<br />OPERATION IS ALLOWED.
<br />2.1.2 MANUFACTURERS:
<br />COOKSON, MODEL FCWI CORNELL IRON WORKS
<br />OVERHEAD DOOR CORPORATION, MODEL 625
<br />RAYNOR DURACOIL STANDARD
<br />SOUTH FLORIDA ROLLING DOORS, INC., MODEL 903
<br />2.2. PUSH-UP COUNTER DOORS (REMODELS ONLY):
<br />2.2.1 THE DOOR CURTAIN SHALL BE CONSTRUCTED OF INTERCONNECTED .040
<br />OR .050 EXTRUDED ALUMINUM NO. 8 (1- 5/16" HIGH BY 3/8" DEEP)
<br />SLATS. THE CURTAIN SHALL RECEIVE A CLEAR ANODIZED FINISH.
<br />2.2.1.1 THE BOTTOM BAR SHALL BE CONSTRUCTED OF TUBULAR EXTRUDED
<br />ALUMINUM MEASURING 1- 5/16" DEEP BY 2- 1 /4" HIGH WITH A
<br />DOUBLE VINYL ASTRAGAL ON THE BOTTOM EDGE. THE BOTTOM BAR
<br />SHALL RECEIVE A CLEAR ANODIZED FINISH.
<br />2.2.1.2 THE GUIDES SHALL BE CONSTRUCTED OF EXTRUDED ALUMINUM AND
<br />MEASURE 1-
<br />3/4" SQUARE. EACH SIDE OF THE CHANNEL PORTION CAPTURING THE
<br />CURTAIN SHALL CONTAIN WOOL PILE WEATHERSTRIPPING. THE GUIDES
<br />SHALL RECEIVE A CLEAR ANODIZED FINISH.
<br />2.2.1.3 THE BRACKETS SHALL BE CONSTRUCTED OF 3/16" THICK DIE CAST
<br />ALUMINUM.
<br />2.2.1.4 THE BARREL SHALL BE STEEL TUBING OF NOT LESS THAT 4" IN
<br />DIAMETER. OIL TEMPERED TORSION SPRINGS SHALL BE CAPABLE OF
<br />CORRECTLY COUNTER BALANCING THE WIDTH OF THE CURTAIN. THE
<br />BARREL SHALL BE DESIGNED TO LIMIT THE MAXIMUM DEFLECTION TO
<br />.03" PER FOOT OF OPENING WIDTH. THE BARREL SHALL RECEIVE ONE(1)
<br />COAT OF BRONZE RUST INHIBITING PRIME PAINT.
<br />2.2.1.5 THE HOOD SHALL BE FABRICATED FROM .040 ALUMINUM AND
<br />TH HOOD SHALL
<br />SHALL BE FORMED TO FIT THE SQUARE BRACKETS E
<br />RECEIVE A CLEAR ANODIZED FINISH.
<br />2.2.2 MANUFACTURERS:
<br />COOKSON, MODEL CD8-1
<br />CORNELL IRON WORKS
<br />OVERHEAD DOOR CORPORATION, MODEL 652
<br />RAYNOR, DURASHUTTER SELECT METRO DOOR,
<br />METRO -GUARD
<br />DYNAMIC ENCLOSURES, MODEL LIFT -READY ROLLING GRILLES "VENTANA"
<br />2.2.3 OPERATION:
<br />2.2.3.1 CHAIN OPERATED OVERHEAD COILING DOORS SHALL OPEN AND
<br />CLOSE WITH A MAXIMUM OF 30 POUNDS OF EFFORT UTILIZING AN
<br />ENDLESS CHAIN AND CAST IRON REDUCTION GEARS.
<br />2.2.3.2 PUSH-UP OPERATED DOORS SHALL OPEN AND CLOSE WITH A
<br />MAXIMUM OF 30 POUNDS OF EFFORT UTILIZING FINGER LIFTS IN THE
<br />BOTTOM BAR.
<br />2.2.4 LOCKING MECHANISM:
<br />2.2.4.1 THE OVERHEAD COILING DOOR CHAIN SHALL BE SECURED BY
<br />MEANS OF A CHAIN LOCK.
<br />2.2.4.2 SPECIAL REQUIREMENT - COASTAL AREAS: HAND CRANK OPERATED
<br />DOORS SHALL HAVE STANDARD SLIDE BOLT LOCKING MECHANISMS ON
<br />COIL SIDE OF DOOR THAT CAN BE SECURED BY PADLOCKS.
<br />2.2.4.3 THE PUSH-UP DOOR SHALL BE SECURED BY MEANS OF A
<br />CONCEALED SLIDING BOLT DEADLOCK IN THE BOTTOM BAR OPERATED BY
<br />A CYLINDER LOCK. CYLINDER LOCK MUST BE RE-KEYABLE.
<br />2.2.5 VISION PANEL: IN DOORS NOT REQUIRED TO MEET MISSILE IMPACT
<br />RESISTANCE, PROVIDE VISION SLATS 12"WIDE X 6 SLATS HIGH. BOTTOM OF
<br />VISION PANEL SHOULD START AT APPROXIMATELY 5' A.F.F.
<br />3. EXECUTION
<br />3.1. INSTALLATION: ALL COILING INSULATED AND PUSH-UP COUNTER DOORS SHALL BE
<br />INSTALLED BY A MANUFACTURER'S AUTHORIZED INSTALLER AND WILL BE IN
<br />ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND STANDARDS.
<br />3.2. WARRANTY: ALL COILING INSULATED AND PUSH-UP COUNTER DOORS SHALL BE
<br />WARRANTED AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE
<br />YEAR FROM THE TIME OF INSTALLATION.
<br />END OF SECTION 08 33 23
<br />SECTION 08 38 00
<br />TRAFFIC DOORS
<br />V06012017
<br />1.1. DESCRIPTION OF WORK: THIS SECTION COVERS ALL TRAFFIC DOORS, INCLUDING
<br />FABRICATION AND ERECTION.
<br />1.2. MANUFACTURER'S RECOMMENDATIONS FOR STORAGE, HANDLING AND PROTECTION SHALL
<br />BE FOLLOWED EXACTLY.
<br />1.3. WARRANTY
<br />1.3.1 PROVIDE MANUFACTURER'S STANDARD 1 YEAR LIMITED WARRANTY FOR
<br />TRAFFIC DOORS AND ALL RELATED PARTS.
<br />1.3.2 ALL OTHER WARRANTIES AND BONDS ARE TO BE IN ACCORDANCE WITH
<br />SECTION 01 77 00
<br />CLOSEOUT PROCEDURES.
<br />2. PRODUCTS
<br />2.1. ACCEPTABLE MANUFACTURERS
<br />2.1.1 TRAFFIC DOOR MANUFACTURERS: SUBJECT TO COMPLIANCE WITH
<br />REQUIREMENTS, PROVIDE PRODUCTS OF THE FOLLOWING:
<br />CHASE INDUSTRIES INC./SENECA HOLDINGS NATIONAL
<br />ACCOUNT CONTACT: NIKKI MORRISSEY
<br />EMAIL: NMORRISSEY®SENECA.COM
<br />OFFICE (269) 492-3934
<br />FAX (800) 245-7045
<br />NATIONAL SALES REP: BEN FRANCO
<br />OFFICE: (419) 280 8176
<br />2.2. TRAFFIC DOORS
<br />2.2.1 DOORS SHALL BE DURULITE "STANDARD" TRAFFIC DOORS CONSTRUCTED
<br />WITH THE OUTER SKIN OF MONOLITHICALLY FORMED, ROTATIONALLY MOLDED,
<br />CROSS LINKED HIGH DENSITY 1 /
<br />8"POLYETHYLENE AND A TEXTURED FINISH. DOOR PANEL THICKNESS SHALL BE 1
<br />7/8".
<br />2.2.2 INSULATION CORE MATERIAL SHALL BE A HIGH DENSITY,
<br />FOAMED -IN -PLACE, RIGID CFC-FREE URETHANE INSULATION. MATERIAL SHALL
<br />BE FOAMED -IN -PLACE AND PROVIDE AN R-VALUE OF
<br />10.83.
<br />2.2.3 POLYETHYLENE TEAR DROP BUMPERS SHALL BE 36 INCHES HIGH AND
<br />FACTORY INSTALLED ON BOTH SIDES OF EACH LEAF USING STAINLESS STEEL
<br />PANEL INSERTS AND FASTENERS. COLOR: BLACK.
<br />2.2.4 PROVIDE 11" INDUSTRIAL LOWER HINGE GUARDS.
<br />2.3. TRAFFIC DOOR HARDWARE
<br />2.3.1 PROVIDE MANUFACTURER'S STANDARD GRAVITY RETURN V-CAM SYSTEM
<br />CONSISTING OF A DUCTILE IRON V-CAM WITH A UHMW SLEEVE AND CAST
<br />ALUMINUM CAM FOLLOWER HOUSING WITH A NEEDLE BEARING ROLLER. THE
<br />ROLLER ASSEMBLY SHALL BE SECURELY CLAMPED ONTO THE SHAFT TO
<br />ALLOW HORIZONTAL AND VERTICAL ADJUSTMENT OF THE DOOR.
<br />2.3.2 AT LOCATIONS INDICATED ON DRAWINGS, PROVIDE LOW-RISE V-CAM AND
<br />BULB LEADING EDGE GASKET TO COMPLY WITH THE ADA ACCESSIBILITY
<br />GUIDELINES.
<br />2.4. TRAFFIC DOOR SEALS
<br />2.4.1 DOORS SHALL BE FULLY GASKETED WITH ALL GASKETS FACTORY APPLIED
<br />WITHOUT THE USE OF METAL STRIPS OR FASTENERS OF ANY TYPE.
<br />2.5. TRAFFIC DOOR VISION PANELS
<br />2.5.1 WINDOW GLAZING SHALL BE 1/8" POLYCARBONATE. ALL WINDOWS SHALL
<br />BE FACTORY INSTALLED AND SEALED. THE EXPOSED SURFACE OF THE
<br />WINDOW SHALL BE RECESSED A MINIMUM OF 1 /8" FROM THE FACE OF THE
<br />DOOR TO PROTECT THE SURFACE FROM ABRASION FROM PASSING LOADS.
<br />2.5.2 WINDOW SIZE SHALL BE 20.5" X 22"
<br />2.5.3 MAXIMUM HEIGHT FROM FINISH FLOOR TO THE BOTTOM OF THE VIEWING
<br />AREA SHALL NOT EXCEED 48 INCHES.
<br />2.6. TRAFFIC DOOR FINISH/COLOR
<br />2.6.1 PRE -FINISHED COLOR: SEE DOOR SCHEDULE FOR COLOR SELECTION.
<br />3. EXECUTION
<br />3.1. INSTALL SPECIAL DOORS COMPLETE WITH NECESSARY HARDWARE AND ACCESSORIES IN
<br />ACCORDANCE WITH FINAL SHOP DRAWINGS, MANUFACTURER'S INSTRUCTIONS AND AS
<br />SPECIFIED HEREIN.
<br />3.2. ALL ASSEMBLIES MUST BE INSTALLED PLUMB, LEVEL AND PROPERLY ALIGNED.
<br />3.3. UPON COMPLETION OF INSTALLATION, LUBRICATE, TEST AND ADJUST DOORS TO OPERATE
<br />EASILY, FREE FROM WARP, TWIST OR DISTORTION.
<br />3.4. ALL DOORS SHALL BE ADA COMPLIANT AND BE ADJUSTED TO ENSURE THE DOOR
<br />CLOSING SWEEP PERIOD AND DOOR OPENING FORCE AS OUTLINED IN THE MOST
<br />CURRENT EDITION OF THE ADA ACCESSIBILITY GUIDELINES AND THE FACBC.
<br />END OF SECTION 08 38 00
<br />SECTION 08 42 29
<br />AUTOMATICENTRANCES
<br />V07212017
<br />1.1. THIS SECTION CONTAINS INFORMATION NORMALLY FOUND IN SECTION 08 81 00 GLASS
<br />GLAZING.
<br />1.2. WIND LOADING: CONFORM TO THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING
<br />JURISDICTION.
<br />1.3. WARRANTIES: INSULATING GLASS PANELS: MANUFACTURER'S STANDARD TEN YEAR
<br />WARRANTY AGAINST ALL DEFECTS.
<br />1.4. SUBMITTALS
<br />1.4.1 SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL
<br />PROCEDURES.
<br />1.4.2 SHOP DRAWINGS:
<br />1.4.2.1 SUBMIT SHOP DRAWINGS IN SUFFICIENT DETAIL TO SHOW
<br />FABRICATION, INSTALLATION, ANCHORAGE, AND INTERFACE OF THE WORK
<br />OF THIS SECTION WITH THE WORK ADJACENT.
<br />1.4.2.2 IN JURISDICTIONS WHERE NOTICE OF ACCEPTANCE (NOA) IS
<br />REQUIRED (AS DESCRIBED IN SECTION 2.1.2): SUBMIT SHOP DRAWINGS
<br />SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF
<br />FLORIDA CERTIFYING THAT ALL REQUIREMENTS OF COUNTY REGULATIONS
<br />ARE MET BY DESIGN PROPOSED.
<br />1.4.2.3 ALL AUTOMATIC DOOR ENTRANCES MUST BE COMPLIANT WITH
<br />ANSI/BHMA
<br />156.10 ACCESSIBILITY STANDARDS.
<br />2. PRODUCTS
<br />2.1. AUTOMATIC ENTRANCE DOORS:
<br />2.1.1 STANDARD PACKAGE: BESAM (ASSA ABLOY) SL 500 SERIES
<br />AUTO -SLIDE AUTOMATIC SLIDING ENTRANCES. WHERE APPLICABLE, INTERIOR
<br />DOOR PACKAGE SHALL INCLUDE TRANSOM W/ 1/4" TEMPERED GLASS.
<br />2.1.2 HIGH VELOCITY WIND ZONES: BESAM(ASSA ABLOY) SL 500
<br />Y HIS ONDITION IS
<br />"HURRICANE" FOR EXTERIOR APPLICATIONS ONL T C
<br />APPLICABLE IN THE FOLLOWING LOCATIONS OR AS REQUIRED IN THE
<br />DRAWINGS:
<br />2.1.2.1 FLORIDA: ENTIRE STATE. MUST MEET ASSEMBLY REQUIREMENTS
<br />AS STATED IN APPROVED MIAMI-DADE COUNTY NOTICE OF ACCEPTANCE
<br />(NOA) AND FLORIDA PRODUCT APPROVAL.
<br />2.1.2.2 GEORGIA: 10 MILES WITHIN THE COAST LINE
<br />2.1.2.3 SOUTH CAROLINA: 10 MILES WITHIN THE COAST LINE
<br />2.1.2.4 ALABAMA: 10 MILES WITHIN THE COAST LINE
<br />2.1.2.5 NORTH CAROLINA: 10 MILES WITHIN THE COAST LINE
<br />2.1.2.6 VIRGINIA: 10 MILES WITHIN THE COAST LINE
<br />2.1.3 SLIDE ACTION: PROVIDE BI-PARTING, BI-PASSING, OR TELESCOPING
<br />ACTION AS SHOWN ON THE DRAWINGS.
<br />2.1.4 FINISH: CLEAR ANODIZED ALUMINUM.
<br />2.1.5 COORDINATE GLAZING, ELECTRICAL, CONTROL WIRING, ETC. WITH OTHER TRADES
<br />AS REQUIRED.
<br />2.1.6 GLAZING FOR AUTOMATIC DOORS AND SIDELIGHTS:
<br />2.1.6.1 IN AREAS LISTED AS HIGH VELOCITY WIND ZONES, PROVIDE
<br />LAMINATED GLASS COMPLYING WITH ASTM C-1172, KIND LA, WHEN
<br />STORE IS LOCATED IN ONE OF THE ZONES LISTED IN SECTION 2.1.2
<br />2.1.6.1.1 PROVIDE EVIDENCE OF PROJECT JURISDICTION PRODUCT APPROVAL.
<br />2.1.6.1.2 GLASS: 7/16" OR 9/16" LAMINATED IMPACT GLASS, OUTER LITES
<br />1/4" ANNEALED FLOAT GLASS, QUALITY Q3, LAMINATED ON BOTH SIDES OF
<br />INNER PLASTIC LAYER, IN SIZES AS REQUIRED.
<br />2.1.6.2 WHEN THE STORE IS NOT LOCATED IN A HIGH VELOCITY WIND
<br />ZONE, AS OUTLINED IN SECTION 2.1.2, USE 1 /4" CLEAR TEMPERED
<br />FLOAT GLASS, ASTM C-
<br />1036, QUALITY 03.
<br />2.1.6.3 TRANSOM PANELS SHALL BE OF THE SAME TYPE OF GLAZING
<br />AS USED IN THE AUTOMATIC DOORS.
<br />2.1.6.4 INTERIOR GLAZING: 1 /4" CLEAR TEMPERED FLOAT GLASS, ASTM
<br />C-1036, QUALITY Q3.
<br />2.2. SEALANTS FOR GLAZING:
<br />2.2.1 WHERE SEALANTS ARE USED IN CONJUNCTION WITH GLAZING SYSTEMS,
<br />USE ONLY THOSE RECOMMENDED BY THE MANUFACTURER OF THE GLAZING
<br />SYSTEM.
<br />2.2.2 UNDER NO CIRCUMSTANCES SHALL WET SEALANTS BE INTRODUCED INTO
<br />GLAZING SYSTEMS TO PROVIDE PRIMARY WEATHERPROOFING OR
<br />WATERPROOFING.
<br />2.2.3 WHERE SEALANTS FOR PERIMETERS OF GLAZING SYSTEMS ABUT OTHER
<br />MATERIALS, USE SEALANTS AS DESCRIBED IN SECTION 07 92 00 JOINT
<br />SEALANTS.
<br />3. EXECUTION
<br />3.1. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE
<br />PERFORMED.
<br />CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF
<br />THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
<br />CORRECTED.
<br />3.2. COORDINATE AS REQUIRED WITH OTHER TRADES TO ASSURE PROPER PROVISION IN THE
<br />WORK OF THOSE TRADES FOR INTERFACE WITH THE WORK OF THIS SECTION.
<br />3.3. ALL TRACKS FOR THE INTERIOR ENTRANCE DOORS MUST BE INSTALLED TO THE
<br />CONCRETE SLAB PRIOR TO THE BEGINNING OF TERRAZZO INSTALLATION. USE ADEQUATE
<br />SHIMMING TO ENSURE TOP OF TRACK IS AT FINISH FLOOR LEVEL (SLAB IS DEPRESSED
<br />APPROXIMATELY 5/8").
<br />3.4. MAKE MEASUREMENTS AS REQUIRED IN THE FIELD TO ASSURE PROPER FIT.
<br />3.5. ALL ALUMINUM SASH SHALL BE CUT TO FIT, FILED AND INSTALLED TO PROVIDE
<br />HAIRLINE FIT AT JOINTS, WITH SMOOTH CONTINUITY OF LINE AND ACCURATE RELATION
<br />OF PLANES AND ANGLES. EXPOSED CAULKING SHALL NOT BE USED.
<br />3.6. PREPARE FOR, RECEIVE, AND INSTALL THE FINISH HARDWARE FURNISHED UNDER
<br />SECTION 08 71 00
<br />DOOR HARDWARE.
<br />3.7. GLAZING AND SETTING
<br />3.7.1 SASH SHALL BE CLEAN AND DRY BEFORE GLAZING. DO NOT GLAZE IN
<br />DAMP OR DUSTY WEATHER OR WHEN TEMPERATURE IS LOWER THAN 40
<br />DEGREES FAHRENHEIT.
<br />3.7.2 IMPROPERLY SET GLASS OR GLASS WHICH DOES NOT FULLY MEET
<br />REQUIREMENTS OF ITS GRADE WILL NOT BE ACCEPTED AND MUST BE
<br />REPLACED TO SATISFACTION OF ARCHITECT WITHOUT
<br />COST TO OWNER.
<br />3.8. CLEANING AND ACCEPTANCE: UPON COMPLETION OF PROJECT: REPLACE ALL CRACKED,
<br />STAINED OR BROKEN GLASS AT NO COST TO OWNER. REMOVE ALL TRACES OF PAINT
<br />AND ETC., AND THOROUGHLY CLEAN ALL SASH BEFORE FINAL ACCEPTANCE OF PROJECT.
<br />END OF SECTION 08 42 29
<br />SECTION 08 43 13
<br />ALUMINUM -FRAMED STOREFRONTS
<br />V04182018
<br />1.1. THIS SECTION CONTAINS INFORMATION NORMALLY FOUND IN SECTION 08 81 00 GLASS
<br />GLAZING.
<br />1.2. WIND LOADING: CONFORM TO THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING
<br />JURISDICTION,
<br />1.3. WARRANTIES: INSULATING GLASS PANELS: MANUFACTURER'S STANDARD TEN YEAR
<br />WARRANTY AGAINST ALL DEFECTS.
<br />1.4. SUBMITTAL
<br />1.4.1 SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL
<br />PROCEDURES.
<br />1.4.2 SHOP DRAWINGS:
<br />1.4.2.1 SUBMIT SHOP DRAWINGS IN SUFFICIENT DETAIL TO SHOW
<br />FABRICATION, INSTALLATION, ANCHORAGE, AND INTERFACE OF THE WORK
<br />OF THIS SECTION WITH THE WORK ADJACENT.
<br />2. PRODUCTS
<br />2.1. ALUMINUM FRAMING:
<br />2.1.1 SIZES AND DESIGNS AS SHOWN ON DRAWINGS. INCLUDE ALL SASH,
<br />CORNER CAPS, AND COVERS, WIND REINFORCEMENT, AND ALL OTHER
<br />COMPONENTS REQUIRED FOR A SECURE, WATERTIGHT INSTALLATION.
<br />2.1.2 INTERIOR AND EXTERIOR FINISH SHALL BE CLEAR ANODIZED ALUMINUM,
<br />AA-M12-C12- A31.
<br />2.1.3 APPROVED MANUFACTURERS: KAWNEER
<br />VI STAWALL
<br />U.S.ALUMINUM
<br />TRULITE PPG TUBELITE YKK
<br />AMERICAN PRODUCTS, INC (API)
<br />2.2. MANUFACTURER'S LABELS, SHOWING STRENGTH AND QUALITY, ARE REQUIRED ON ALL
<br />GLASS, AND ARE NOT TO BE REMOVED UNTIL INSPECTED AND APPROVED BY PUBLIX'
<br />REPRESENTATIVE. ALL GLASS SHALL CONFORM TO FED SPEC DD-6-451A. TEMPERED
<br />GLASS SHALL BE SO MARKED, PERMANENTLY, IN AN INCONSPICUOUS LOCATION ON THE
<br />PANEL.
<br />2.3. EXTERIOR GLAZING:
<br />2.3.1 LAMINATED GLAZING: 9/16" MISSILE IMPACT TO BE USED FOR SHELL
<br />GLAZING AND PUBLIX- DESIGNED FACADE GLAZING (DEVELOPER -DESIGNED
<br />FACADE GLAZING EXEMPT) IN THE FOLLOWING LOCATIONS OR AS REQUIRED IN
<br />THE DRAWINGS:
<br />2.3.1.1 FLORIDA: ENTIRE STATE. MUST MEET ASSEMBLY REQUIREMENTS
<br />AS STATED IN APPROVED MIAMI-DADE NOTICE OF ACCEPTANCE (NOA)
<br />AND FLORIDA PRODUCT APPROVAL.
<br />2.3.1.2 GEORGIA: 10 MILES WITHIN THE COAST LINE
<br />2.3.1.3 SOUTH CAROLINA:10 MILES WITHIN THE COAST LINE
<br />2.3.1.4 ALABAMA: 10 MILES WITHIN THE COAST LINE
<br />2.3.1.5 NORTH CAROLINA: 10 MILES WITHIN THE COAST LINE
<br />2.3.1.6 VIRGINIA: 10 MILES WITHIN THE COAST LINE
<br />2.3.2 APPROVED PRODUCTS:
<br />SAFETY PLUS -II, GLASSLAM NGI
<br />SAF-GLAS, IMPACT SECURITY PRODUCTS, INC.
<br />STORMGARD, VIRACON
<br />STORMGLASS, OLDCASTLE
<br />PPG
<br />2.3.3 ELSEWHERE, PROVIDE SEALED INSULATING PANELS COMPOSED OF TWO
<br />LITES 1/4" CLEAR TEMPERED FLOAT GLASS, IN SIZES AS DESCRIBED ON
<br />DRAWINGS AND VERIFIED IN FIELD.
<br />2.3.3.1 GLASS: ASTM C-1036, QUALITY Q3.
<br />2.3.3.2 SEALED PANELS: ASTM E-774, CLASS B.
<br />2.3.4 EXTERIOR STOREFRONT DOOR (WHERE APPLICABLE). THE FOLLOWING ITEMS
<br />ARE TO BE
<br />INCLUDED WITH THE DOOR AND PROVIDED BY THE STORE FRONT DOOR PROVIDER:
<br />1 EA. DOOR CLOSER
<br />1 EA. DOOR PULL
<br />1 EA. PUSH BAR
<br />1 EA. THUMB TURN
<br />2.4. INTERIOR GLAZING: 1/4" CLEAR TEMPERED FLOAT GLASS, ASTM C-1036, QUALITY 03,
<br />IN SIZES AS REQUIRED.
<br />2.5. SEALANTS FOR GLAZING:
<br />2.5.1 WHERE SEALANTS ARE USED IN CONJUNCTION WITH GLAZING SYSTEMS,
<br />USE ONLY THOSE RECOMMENDED BY THE MANUFACTURER OF THE GLAZING
<br />SYSTEM.
<br />2.5.2 UNDER NO CIRCUMSTANCES SHALL WET SEALANTS BE INTRODUCED INTO
<br />GLAZING SYSTEMS TO PROVIDE PRIMARY WEATHERPROOFING OR
<br />WATERPROOFING.
<br />2.5.3 WHERE SEALANTS FOR PERIMETERS OF GLAZING SYSTEMS ABUT OTHER
<br />MATERIALS, USE SEALANTS AS DESCRIBED IN SECTION 07 92 00 JOINT
<br />SEALANTS.
<br />3. EXECUTION
<br />3.1. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE
<br />PERFORMED.
<br />CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF
<br />THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
<br />CORRECTED.
<br />3.2. COORDINATE AS REQUIRED WITH OTHER TRADES TO ASSURE PROPER PROVISION IN THE
<br />WORK OF THOSE TRADES FOR INTERFACE WITH THE WORK OF THIS SECTION.
<br />3.3. MAKE MEASUREMENTS AS REQUIRED IN THE FIELD TO ASSURE PROPER FIT.
<br />3.4. ALL ALUMINUM SASH SHALL BE CUT TO FIT, FILED AND INSTALLED TO PROVIDE
<br />HAIRLINE FIT AT JOINTS, WITH SMOOTH CONTINUITY OF LINE AND ACCURATE RELATION
<br />OF PLANES AND ANGLES. EXPOSED
<br />CAULKING SHALL NOT BE USED.
<br />3.5. GLAZING AND SETTING
<br />3.5.1 SASH SHALL BE CLEAN AND DRY BEFORE GLAZING. DO NOT GLAZE IN
<br />DAMP OR DUSTY WEATHER OR WHEN TEMPERATURE IS LOWER THAN 40
<br />DEGREES FAHRENHEIT.
<br />3.5.2 COORDINATE WITH OTHERS TO SEE THAT SUFFICIENT BLOCKING IS RIGIDLY
<br />IN PLACE AND THAT FINISH MATERIAL WILL FIT SILL COVERS, JAMBS, ETC.
<br />INSTALL STORE FRONT SASH SECURELY AND NEATLY AND CAULK FULLY TO
<br />PRODUCE WATERTIGHT AREA. ANCHOR DIVISION BARS TO STOOL FRAMING AND
<br />WOOD GROUND ABOVE.
<br />3.5.3 IMPROPERLY SET GLASS OR GLASS WHICH DOES NOT FULLY MEET
<br />REQUIREMENTS OF ITS GRADE WILL NOT BE ACCEPTED AND MUST BE
<br />REPLACED TO SATISFACTION OF ARCHITECT WITHOUT COST TO OWNER.
<br />3.6. CLEANING AND ACCEPTANCE: UPON COMPLETION OF PROJECT: REPLACE ALL CRACKED,
<br />STAINED OR BROKEN GLASS AT NO COST TO OWNER. REMOVE ALL TRACES OF PAINT
<br />AND ETC., AND THOROUGHLY CLEAN ALL SASH BEFORE FINAL ACCEPTANCE OF PROJECT.
<br />END OF SECTION 08 43 13
<br />^�
<br />W
<br />10
<br />N
<br />CD
<br />O
<br />-1
<br />�N
<br />0 �
<br />00
<br />U
<br />�
<br />U
<br />"(s
<br />' '
<br />Q
<br />5
<br />U
<br />V
<br />O n
<br />``0 ``O�
<br />W �/
<br />`%
<br />U
<br />� "g
<br />r- r-
<br />wA
<br />'
<br />00
<br />0
<br />�
<br />� �
<br />A
<br />m
<br />0
<br />N
<br />Q co
<br />N
<br />Z W M
<br />m z F- N
<br />w W Qi
<br />U �
<br />� U� O
<br />F_
<br />o O
<br />w w
<br />o a
<br />U
<br />VJ
<br />F_
<br />W
<br />�Y_
<br />w
<br />cQ a
<br />G
<br />O. a
<br />nW �v-
<br />` L g M
<br />�ZOv-
<br />/)� a
<br />V) O 2
<br />M
<br />U U_
<br />X
<br />w M6 = Z
<br />z ■.. aW
<br />I- � C) QY
<br />Z M _7
<br />w
<br />J
<br />U
<br />"
<br />r
<br />�4t
<br />VJ
<br />Z
<br />O
<br />CG
<br />G
<br />O
<br />)
<br />w
<br />\_ (V
<br />/" o
<br />2 M
<br />IT
<br />0- �
<br />W m
<br />M
<br />M
<br />N o
<br />w
<br />O
<br />LL.
<br />>
<br />J J
<br />w m
<br />J_
<br />Z _j J =
<br />0 (7 �
<br />O Z) M a
<br />a �N
<br />v
<br />2
<br />a(L
<br />_j
<br />0g
<br />•5
<br />bA •
<br />WO
<br />0
<br />U� Z
<br />U J
<br />(U fY
<br />Z)
<br />Z
<br />C<
<br />G
<br />F-
<br />U
<br />W
<br />J
<br />�0
<br />LU � r
<br />H
<br />w
<br />w
<br />s
<br />•
<br />�.•
<br />' `!
<br />_
<br />0
<br />•"0
<br />_
<br />�
<br />v"•
<br />�•
<br />w
<br />rn
<br />a m
<br />•' r
<br />a
<br />��� '•.
<br />.`�
<br />�`
<br />U
<br />`S ••�RE
<br />..
<br />U
<br />9
<br />0
<br />a
<br />8
<br />m
<br />N
<br />N
<br />J
<br />H
<br />f-
<br />m
<br />w
<br />�
<br />CO
<br />U)
<br />J
<br />w
<br />o
<br />rn
<br />O
<br />o
<br />z
<br />M
<br />"
<br />U
<br />�
<br />00
<br />N
<br />w
<br />N
<br />o
<br />z
<br />�
<br />U
<br />w
<br />U
<br />�
<br />�-
<br />�
<br />=
<br />�
<br />¢
<br />a
<br />0
<br />0
<br />U
<br />WW 2019
<br />Construction,
<br />
|