v
<br />SECTION 08 56 59
<br />SERVICE AND TELLER WINDOW UNITS
<br />V01262018
<br />1.1. THIS SECTION CONTAINS INFORMATION PERTAINING TO THE PHARMACY VISION AND
<br />TRANSACTION WINDOW AND THE CAFE SERVICE WINDOW WHEN THEY OCCUR AS
<br />INDICATED ON THE CONSTRUCTION DRAWINGS.
<br />1.2. WIND LOADING: CONFORM TO THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING
<br />JURISDICTION,
<br />1.3. SUBMITTALS:
<br />1.3.1 SHOP DRAWINGS:
<br />1.3.1.1 SUBMIT SHOP DRAWINGS IN SUFFICIENT DETAIL TO SHOW
<br />INSTALLATION, ANCHORAGE, AND INTERFACE OF THE WORK OF THIS
<br />SECTION WITH THE WORK ADJACENT.
<br />1.3.1.2 STORES LOCATED IN FLORIDA AND COASTAL COUNTIES (SEE
<br />ARTICLE 1.4 OF THIS SECTION): SUBMIT SHOP DRAWINGS SIGNED AND
<br />SEALED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA
<br />CERTIFYING THAT ALL REQUIREMENTS OF COUNTY REGULATIONS ARE
<br />MET BY DESIGN PROPOSED.
<br />1.3.1.3 PRODUCT CERTIFICATES: SIGNED BY PRODUCT MANUFACTURER,
<br />INDICATING LEVEL OF BALLISTICS RESISTANCE PROVIDED.
<br />1.4. HIGH VELOCITY WIND ZONES: THIS CONDITION IS APPLICABLE IN THE FOLLOWING
<br />LOCATIONS OR AS REQUIRED IN THE DRAWINGS:
<br />1.4.1 FLORIDA: ENTIRE STATE. MUST MEET ASSEMBLY REQUIREMENTS AS STATED IN
<br />APPROVED
<br />MIAMI-DADE COUNTY NOTICE OF ACCEPTANCE (NOA).
<br />1.4.2 GEORGIA: 10 MILES WITHIN THE COAST
<br />1.4.3 SOUTH CAROLINA: 10 MILES WITHIN THE COAST
<br />1.4.4 ALABAMA: 10 MILES WITHIN THE COAST
<br />1.4.5 NORTH CAROLINA: 10 MILES WITHIN THE COAST
<br />1.4.6 VIRGINIA: 10 MILES WITHIN THE COAST
<br />1.4.7 INSTALLER QUALIFICATIONS: AN AUTHORIZED REPRESENTATIVE OF VISION
<br />AND TRANSACTION WINDOW MANUFACTURER FOR INSTALLATION AND
<br />MAINTENANCE OF UNITS REQUIRED FOR PROJECT.
<br />1.5. STORAGE AND HANDLING: STORE CRATED VISION AND TRANSACTION WINDOW ON
<br />RAISED BLOCKS TO PREVENT MOISTURE DAMAGE.
<br />1.6. FIELD MEASUREMENTS: VERIFY VISION AND TRANSACTION WINDOW OPENINGS BY
<br />FIELD MEASUREMENTS BEFORE FABRICATION. COORDINATE WALL CONSTRUCTION TO
<br />ENSURE THAT ACTUAL OPENING DIMENSIONS CORRESPOND TO ESTABLISHED
<br />DIMENSIONS PROVIDED BY MANUFACTURER.
<br />1.7. WARRANTY:
<br />1.7.1 MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO
<br />REPAIR OR REPLACE COMPONENTS OF THE VISION AND TRANSACTION WINDOW
<br />THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY
<br />PERIOD. FAILURES INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:
<br />1.7.1.1 STRUCTURAL FAILURES INCLUDING DEFLECTIONS EXCEEDING 1/8 INCH.
<br />1.7.1.2 FAILURE OF WELDS.
<br />1.7.1.3 EXCESSIVE AIR LEAKAGE.
<br />1.7.1.4 FAULT OPERATION OF TRANSACTION DRAWER.
<br />1.7.1.5 DETERIORATION OF METALS, METAL FINISHES AND OTHER
<br />MATERIALS BEYOND NORMAL WEATHERING AND USE.
<br />1.7.2 WARRANTY PERIOD:
<br />1.7.2.1 TRANSACTION DRAWER: TWO YEARS FROM DATE OF SUBSTANTIAL
<br />COMPLETION.
<br />1.7.2.2 VISION WINDOW: FIVE YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />1.7.2.3 OTHER ITEMS: ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION.
<br />2. PRODUCTS
<br />2.1. THE VISION WINDOW AND TRANSACTION DRAWER AT THE PHARMACY WILL BE
<br />SUPPLIED BY THE FOLLOWING COMPANY:
<br />E.F. BAVIS AND ASSOCIATES, INC.
<br />TERRY ROBERTS, DIRECTOR - MARKETING AND SALES
<br />TELEPHONE: (513) 677-0500 EXT. 106
<br />FAX: (513) 677-0552
<br />E-MAIL: TAR@BAVIS.COM
<br />2.1.1 VISION WINDOW:
<br />60" BASIC TRIMLESS WINDOW
<br />-OR-
<br />HVHZ 60" TRIMLESS WINDOW (HIGH VELOCITY WIND ZONES AS
<br />DESCRIBED IN SECTION 1.4)
<br />2.1.1.1 BALLISTICS RESISTANCE: LEVEL 1 WHEN TESTED ACCORDING TO UL 752.
<br />2.1.1.2 FINISH COLOR: BAVIS TEXTURED GRAY.
<br />2.1.2 TRANSACTION DRAWER: BASIC DRAWER 2
<br />-OR-
<br />MANUAL DRAWER WITH FLUSH AUDIO PANEL (HIGH VELOCITY WIND ZONES)
<br />2.1.2.1 HEATER: ORDER 115 VAC HEATER IN STORES LOCATED IN THE STATES
<br />OF
<br />TENNESSEE, NORTH CAROLINA AND VIRGINIA.
<br />2.1.2.2 BALLISTICS RESISTANCE: SAME AS VISION WINDOW.
<br />2.2. WIRELESS ANNUNCIATOR SYSTEM:
<br />2.2.1 RECEIVER:
<br />WIRELESS 1000 RC-10, OPTEX
<br />2.2.2 OUTDOOR SENSOR TRANSMITTER:
<br />WIRELESS 1000 TD-10, OPTEX
<br />2.3. CAFE WINDOW (WHERE SHOWN ON PLANS):
<br />SC4030, QUIKSERV CORP.
<br />2.4. SEALANTS:
<br />2.4.1 UNDER NO CIRCUMSTANCES SHALL WET SEALANTS BE INTRODUCED INTO
<br />GLAZING SYSTEMS TO PROVIDE PRIMARY WEATHERPROOFING OR
<br />WATERPROOFING.
<br />2.4.2 WHERE SEALANTS FOR PERIMETERS OF GLAZING SYSTEMS ABUT OTHER
<br />MATERIALS, USE SEALANTS AS DESCRIBED IN SECTION 07 92 00 JOINT
<br />SEALANTS.
<br />3. EXECUTION
<br />3.1. EXAMINE THE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL
<br />BE PERFORMED.
<br />CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF
<br />THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
<br />CORRECTED.
<br />3.2. COORDINATE AS REQUIRED WITH OTHER TRADES TO ASSURE PROPER PROVISION IN
<br />THE WORK OF THOSE TRADES FOR INTERFACE WITH THE WORK OF THIS SECTION.
<br />3.3. MAKE MEASUREMENTS AS REQUIRED IN THE FIELD TO ASSURE PROPER FIT.
<br />3.4. WIRELESS ANNUNCIATOR SYSTEM: THE INSTALLER OF THE WINDOW AND
<br />TRANSACTION DRAWER WILL BE RESPONSIBLE FOR THE INSTALLATION OF THIS
<br />EQUIPMENT.
<br />3.4.1 OUTDOOR SENSOR TRANSMITTER: MOUNT TO PHARMACY CANOPY SO AS
<br />TO BE PROTECTED FROM DIRECT EXPOSURE TO WEATHER. THE SENSOR
<br />SHOULD BE SET SO AS TO NOTIFY OF AN AUTOMOBILE'S APPROACH TO THE
<br />TRANSACTION WINDOW.
<br />3.4.2 RECEIVER: MOUNT ON WALL NEXT TO VISION WINDOW. OUTLET FOR
<br />POWER PROVIDED BY ELECTRICAL WORK.
<br />3.5. TRANSACTION DRAWER HEATER: USE THE SAME OUTLET AS THE CHIME BOX FOR
<br />THE WIRELESS ANNUNCIATOR SYSTEM.
<br />3.6. SEALANTS: SEAL FRAME PERIMETER WITH SEALANT TO PROVIDE WEATHERTIGHT
<br />CONSTRUCTION, UNLESS OTHERWISE INDICATED.
<br />3.7. FIELD QUALITY CONTROL:
<br />3.7.1 COORDINATE WITH MANUFACTURER REPRESENTATIVE TO INSPECT AND
<br />VERIFY COMPLIANCE OF INSTALLED PRODUCTS WITH REQUIREMENTS.
<br />3.7.2 REMOVE AND REPLACE WORK WHERE INSPECTIONS INDICATED THAT
<br />WORK DOES NOT COMPLY WITH SPECIFIED REQUIREMENTS.
<br />3.7.3 PERFORM ADDITIONAL INSPECTIONS TO DETERMINE COMPLIANCE OF
<br />REPLACED OR ADDITIONAL WORK.
<br />3.8. ADJUSTING:
<br />3.8.1 ADJUST TRANSACTION DRAWERS TO PROVIDE A TIGHT FIT AT CONTACT
<br />POINTS FOR SMOOTH OPERATION AND SECURE ENCLOSURE.
<br />3.9. CLEANING: CLEAN SURFACES PROMPTLY AFTER INSTALLATION OF VISION WINDOW
<br />AND TRANSACTION DRAWER. EXERCISE CARE TO AVOID DAMAGING THE FINISH.
<br />REMOVE EXCESS GLAZING AND SEALING COMPOUNDS, DIRT AND OTHER
<br />SUBSTANCES.
<br />3.9.1 CLEAN GLASS PROMPTLY AFTER INSTALLATION USING CLEANERS
<br />RECOMMENDED BY MANUFACTURER. DO NOT USE RAZORS TO CLEAN
<br />GLASS.
<br />3.9.2 FOLLOW MANUFACTURER'S INSTRUCTIONS REGARDING LUBRICATION OF
<br />TRANSACTION DRAWER HARDWARE.
<br />3.10. DEMONSTRATION:
<br />3.10.1 ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN
<br />PUBLIX MAINTENANCE PERSONNEL TO ADJUST, OPERATE AND MAINTAIN THE
<br />VISION WINDOW, TRANSACTION DRAWER AND WIRELESS ANNUNCIATOR SYSTEM.
<br />END OF SECTION 08 56 59
<br />SECTION 08 71 00
<br />DOOR HARDWARE
<br />V06282018
<br />1.1.1 HARDWARE SCHEDULE: SUBMIT A COMPLETE SCHEDULE OF HARDWARE
<br />USING THE FORMAT OF THIS SPECIFICATION, INDICATING TYPE, NUMBER,
<br />LOCATION AND FINISH OF EACH ITEM. INCLUDE MANUFACTURER'S NAME AND
<br />MODEL DESCRIPTION, FASTENING DEVICES AND COMPLETE KEYING SCHEDULE.
<br />REFERENCE ARCHITECT'S DOOR DESIGNATION.
<br />1.1.2 PROVIDE A CROSS-REFERENCE BETWEEN DOOR NUMBERS AND HARDWARE
<br />HEADINGS.
<br />1.1.3 TEMPLATES: FURNISH TEMPLATES AND APPROVED SCHEDULE TO EACH
<br />RELATED MANUFACTURER OF EQUIPMENT WHICH REQUIRE SAME FOR THE
<br />FABRICATION OF THEIR MATERIAL.
<br />1.1.4 NO SUBSTITUTIONS WILL BE ALLOWED.
<br />1.2. QUALITY ASSURANCE
<br />1.2.1 PROVIDE HARDWARE IN COMPLIANCE WITH THE LOCAL BUILDING CODE
<br />REQUIREMENTS. ALSO COMPLY WITH NFPA101 LIFE SAFETY CODE AND ANSI
<br />A117.1 WHERE APPLICABLE.
<br />1.2.2 PROVIDE HARDWARE FOR FIRE RATED OPENINGS IN ACCORDANCE WITH
<br />NFPA 80, (FIRE DOORS AND WINDOWS) AND NFPA 105 (SMOKE AND DRAFT
<br />CONTROL DOOR ASSEMBLIES).
<br />1.3. DELIVERY STORAGE AND HANDLING
<br />1.3.1 DELIVER HARDWARE TO PROJECT SITE IN MANUFACTURER'S PROTECTIVE
<br />PACKAGING, ALL ITEMS ARE TO BE MARKED TO INDICATE DOOR OPENING
<br />NUMBER, HARDWARE SCHEDULE NUMBER OR OTHER IDENTIFYING MARKS.
<br />1.3.2 STORE HARDWARE IN SECURE LOCK -UP AREA, DRY AND LIGHTED.
<br />1.4. WARRANTY
<br />1.4.1 WARRANT DOOR CLOSERS AGAINST FAILURE DUE TO DEFECTIVE MATERIALS
<br />AND WORKMANSHIP FOR A PERIOD OF FIVE (5) YEARS BEGINNING AT DATE
<br />OF SUBSTANTIAL COMPLETION. CLOSERS JUDGED DEFECTIVE DURING THIS
<br />PERIOD SHALL BE REPLACED OR REPAIRED AT NO COST TO THE OWNER.
<br />1.4.2 WARRANT EXIT DEVICES AGAINST FAILURE DUE TO DEFECTS IN MATERIAL
<br />OR WORKMANSHIP FOR A PERIOD OF THREE (3) YEARS.
<br />1.4.3 ALL OTHER WARRANTIES AND BONDS ARE TO BE IN ACCORDANCE WITH
<br />SECTION 01700 - CONTRACT CLOSE-OUT.
<br />2. PRODUCTS
<br />2.1. FINISH:
<br />2.1.1 FINISH, UNLESS OTHERWISE INDICATED, SHALL BE US26D. (BRUSHED CHROME)
<br />2.1.2 DOOR CLOSERS SHALL BE SPRAY -PAINTED FOR FINISH TO MATCH ADJACENT
<br />HARDWARE.
<br />2.2. CYLINDERS: ACCEPTABLE MANUFACTURER: SARGENT OR SCHLAGE
<br />2.3. LOCK COMPANY.
<br />2.3.1 REMODEL ONLY: ANY REPLACEMENT CYLINDERS SHOULD BE OF THE
<br />SAME MANUFACTURER OF THE PREDOMINANT EXISTING CYLINDERS THAT ARE
<br />IN THE STORE. THE GENERAL CONTRACTOR OR SUBCONTRACTOR MUST
<br />VERIFY THIS INFORMATION WITH THE PUBLIX FACILITIES CONSTRUCTION
<br />REPRESENTATIVE.
<br />2.3.2 CYLINDERS SHALL BE KEYED ALIKE. NO MASTER KEYING OR
<br />CONSTRUCTION MASTER KEYING IS REQUIRED.
<br />2.3.3 PROVIDE SIX KEYS.
<br />2.4. HINGES:
<br />2.4.1 ACCEPTABLE MANUFACTURERS: MCKINNEY
<br />HAGER
<br />DOUBLE-ACTING SPRING HINGES: BOMMER INDUSTRIES, INC.
<br />2.4.2 HINGES SHALL BE THE TYPES, MATERIALS, SIZES, AND FINISHES
<br />INDICATED IN FINISH HARDWARE SCHEDULE.
<br />2.5. LOCKSETS, PASSAGE SETS, CYLINDERS:
<br />2.5.1 ACCEPTABLE MANUFACTURER: SARGENT LOCK CO.
<br />2.5.2 LOCKSET AND PASSAGE SET SERIES AND DESIGN SHALL BE "D" SERIES
<br />(HEAVY DUTY), RHODES LEVER DESIGN.
<br />2.5.3 CYLINDERS SHALL BE MORTISE OR RIM, SIX PIN TYPE COMPLETE WITH
<br />CAM AND/OR TAIL PIECE FOR EXIT DEVICES.
<br />2.6. EXIT DEVICES WITH ALARM KITS:
<br />2.6.1 ACCEPTABLE MANUFACTURER: DETEX.
<br />2.6.2 ACCEPTABLE MANUFACTURER (NON -ALARMED): SARGENT.
<br />2.6.3 EXIT DEVICES SHALL BE LISTED BY UNDERWRITER'S LABORATORIES, INC.
<br />FOR ACCIDENT HAZARD. EXIT DEVICES FOR USE ON FIRE -RATED OPENING
<br />SHALL BEAR FACTORY INSTALLED UL MARKINGS THAT INDICATE A THREE (3)
<br />HOUR FIRE RATING.
<br />2.6.4 ALL EXIT DEVICES SHALL BE NON -HANDED. TOUCH PAD SHALL EXTEND A
<br />MINIMUM OF 3/4 OF THE DOOR WIDTH AND SHALL BE A MINIMUM OF
<br />2-1/16" IN HEIGHT. LATCHBOLTS SHALL HAVE A SELF-LUBRICATING COATING
<br />TO REDUCE WEAR. PLATED OR PLASTIC COATED LATCHBOLTS ARE NOT
<br />ACCEPTABLE.
<br />2.7. SURFACE MOUNTED DOOR CLOSERS:
<br />2.7.1 ACCEPTABLE MANUFACTURERS AND PRODUCTS:
<br />SARGENT: 1431
<br />2.7.2 ALL SURFACE CLOSERS SHALL BE OF ONE MANUFACTURER. THE
<br />CLOSERS SHALL BE NON- HANDED AND NON -SIZED, HYDRAULICALLY
<br />CONTROLLED WITH FULL RACK AND PINION OPERATION. THEY SHALL HAVE
<br />ADJUSTMENTS FOR BACKCHECK, GENERAL SPEED, AND LATCH SPEED.
<br />CLOSERS SHALL MEET AN OPENING FORCE BELOW 5 LBS. TO MEET BARRIER
<br />FREE
<br />REQUIREMENTS.
<br />2.7.3 WHERE A CLOSER REQUIRES A 'PS' (STOP ARM) LABEL, THE DOOR WILL BE
<br />LIMITED TO 90'
<br />OPENING AT INTERIOR DOORS AND 100' AT EXTERIOR DOORS.
<br />2.7.4 PROVIDE MOUNTING PLATES AS REQUIRED, SEX NUTS AND BOLTS FOR
<br />APPLICATION TO HOLLOW METAL DOORS, AND THRU BOLTS FOR APPLICATION
<br />TO WOOD DOORS.
<br />2.8. STOPS, HOLDERS, BOLTS, VIEWERS, AND MISCELLANEOUS:
<br />2.8.1 ACCEPTABLE MANUFACTURERS: SARGENT
<br />MCKINNEY
<br />ROCKWOOD
<br />2.8.2 TYPES AS INDICATED IN HARDWARE SCHEDULE.
<br />2.8.3 FLUSH BOLTS SHALL BE 1" X 6-3/4" BRASS, RECTANGULAR FRONT, LENGTHS
<br />INDICATED, WITH
<br />3/4" THROW. FURNISH BOTTOM STRIKE AND TOP STRIKE PLATES.
<br />2.8.4 BOLTS AND ACCESSORIES FOR USE ON FIRE -RATED DOORS SHALL
<br />BE UNDERWRITERS' LABORATORIES LISTED.
<br />2.9. FLAT GOODS:
<br />2.9.1 ACCEPTABLE MANUFACTURERS: ROCKWOOD
<br />DON-JO (LATCH PROTECTORS ONLY)
<br />2.10. THRESHOLDS, SWEEPS AND WEATHER-STRIP
<br />2.10.1 PROVIDE EXTRA HEAVY DUTY VERMIN STRIP, 3" HEIGHT, WITH
<br />STAINLESS STEEL OR ALUMINUM RECEIVER FOR NEOPRENE SWEEP.
<br />2.10.2 ACCEPTABLE MANUFACTURERS: PEMKO
<br />MCKINNEY
<br />2.11. ANY PRODUCTS THAT DO NOT HAVE A MANUFACTURER LISTING ARE
<br />NON-PROPRIETARY.
<br />3. EXECUTION
<br />3.1. PRELIMINARY
<br />3.1.1 STORE IN TEMPORARY BINS. TAG, INDEX, AND FILE ALL KEYS
<br />TEMPORARILY DURING CONSTRUCTION.
<br />3.1.2 CHECK ALL HARDWARE UPON ARRIVAL ON JOB SITE AGAINST APPROVED
<br />FINISH HARDWARE SCHEDULE. CHECK FUNCTION OF HARDWARE FOR JOB USE
<br />UNDER SITE CONDITIONS AND INTERFERENCES. NOTIFY ARCHITECT IF
<br />DISCREPANCIES OCCUR.
<br />3.2. INSTALLATION
<br />3.2.1 INSTALL HARDWARE TO DOORS AS LISTED IN THE DOOR SCHEDULE.
<br />COMPLY WITH "RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE FOR
<br />CUSTOM STEEL DOORS AND FRAMES" AS PUBLISHED BY THE DOOR AND
<br />HARDWARE INSTITUTE. APPLICATION SHALL BE BY SKILLED WORKMEN, WHO
<br />WORK WITH PROPER EQUIPMENT, AND SHALL BE IN ACCORD
<br />WITH THE MANUFACTURER'S INSTRUCTIONS, FIT TO WORK OF OTHERS
<br />ACCURATELY, APPLIED SECURELY, AND ADJUSTED PROPERLY. HARDWARE LET
<br />INTO WORK OF OTHERS SHALL BE NEATLY DONE FROM TEMPLATE AND SHALL
<br />FIT PERFECTLY. EXERCISE CARE NOT TO DAMAGE WORK OF OTHERS.
<br />3.2.2 INSTALL FINISH HARDWARE TO TEMPLATE. CUT AND FIT SUBSTRATE TO
<br />AVOID SUBSTRATE DAMAGE OR WEAKENING. COVER CUT-OUTS WITH HARDWARE
<br />ITEM. MORTISE WORK TO CORRECT LOCATION AND SIZE WITHOUT GOUGING,
<br />SPLINTERING, OR CAUSING IRREGULARITIES IN EXPOSED FINISHED WORK.
<br />3.2.3 WHERE CUTTING AND FITTING IS REQUIRED ON SUBSTRATES TO BE
<br />PAINTED OR SIMILARLY FINISHED, INSTALL, FIT, AND ADJUST HARDWARE PRIOR
<br />TO FINISHING, AND THEN REMOVE AND PLACE IN ORIGINAL PACKAGING.
<br />REINSTALL HARDWARE AFTER FINISHING OPERATION IS COMPLETED.
<br />3.2.4 ATTACH THRESHOLDS WITH FLATHEAD SCREWS INTO EMBEDDED
<br />RECEIVERS, SYMMETRICAL WITH THE CENTER OF DOOR OPENING. ON CASE
<br />THRESHOLDS WHERE CAST -ON ANCHORS ARE USED, APPLY UTILIZING AN
<br />EPDXY GROUT MIXTURE.
<br />3.2.5 ATTACH DOOR CLOSERS TO DOOR WHETHER WOOD OR METAL, WITH
<br />SEX NUT AND BOLT ASSEMBLIES. WHERE CLOSERS HAVE STOP FUNCTION,
<br />INSTALL CLOSER TO STOP THE DOOR BEFORE STRIKING OBSTRUCTIONS.
<br />3.3. FINISHING:
<br />3.3.1 ALL LATCH PROTECTORS TO BE PAINTED WITH SAME PAINT AS EXTERIOR
<br />DOORS.
<br />3.4. CLEANING AND ADJUSTING
<br />3.4.1 AT THE TIME OF HARDWARE INSTALLATION, ADJUST EACH HARDWARE ITEM
<br />TO PERFORM FUNCTION INTENDED. LUBRICATE MOVING PARTS WITH LUBRICANT
<br />ACCEPTABLE TO HARDWARE MANUFACTURER TO REMOVE DUST AND STAINS.
<br />3.4.2 PRIOR TO SUBSTANTIAL COMPLETION, READJUST AND RE -LUBRICATE
<br />HARDWARE REPAIR OR REPLACE DEFECTIVE MATERIALS. CLEAN HARDWARE AS
<br />RECOMMENDED BY MANUFACTURER TO REMOVE DUST AND STAINS.
<br />3.5. FASTENINGS
<br />3.5.1 ALL EXPOSED SCREWS SHALL BE PHILLIPS HEAD, FINISHED TO MATCH
<br />ITEM AND SIZED TO SUIT JOB REQUIREMENTS.
<br />3.5.2 SURFACE APPLIED ITEMS SUCH AS CLOSERS AND OVERHEAD HOLDERS
<br />SHALL BE APPLIED WITH SEX NUT AND BOLT ASSEMBLIES.
<br />3.6. OPERATION AND ADJUSTMENT
<br />3.6.1 ADJUST ALL INSTALLED ITEMS FOR PROPER OPERATION WITHOUT BINDING OR
<br />EXCESSIVE PLAY.
<br />3.6.2 CLOSERS AND OTHER DOOR OPERATING HARDWARE SHALL BE ADJUSTED
<br />TO COMPLY WITH REQUIREMENTS OF LOCAL CODES AND IN ACCORDANCE WITH
<br />PERFORMANCE REQUIREMENTS OF ADA AND OTHER HANDICAP REGULATIONS.
<br />3.7. COMPLETION
<br />3.7.1 AFTER INSTALLATION, ALL TEMPLATES, INSTALLATION INSTRUCTIONS,
<br />AS-BUILTS AND OTHER PERTINENT INFORMATION SHALL PLACED IN A
<br />PROPERLY IDENTIFIED BINDER. THIS BINDER AND ALL SPECIAL TOOLS ARE TO
<br />BE TURNED OVER TO THE OWNER'S REPRESENTATIVE AT FINAL ACCEPTANCE
<br />OF THE PROJECT.
<br />3.7.2 AFTER FINAL ACCEPTANCE, THE HARDWARE SUPPLIER SHALL INSTRUCT
<br />THE OWNER'S DESIGNATED PERSONNEL IN THE PROPER OPERATION,
<br />ADJUSTMENT AND MAINTENANCE OF HARDWARE AND FINISHES.
<br />3.8. HARDWARE SCHEDULE
<br />3.8.1 ALL DOOR -SPECIFIC OPTIONS ARE NOTED IN THE DOOR
<br />SCHEDULE.
<br />3.8.2 GROUP A -1A
<br />EXIT (PANIC BAR, EXIT ONLY), WITH ALARM, CLOSER W/H.O.; DOORS FROM STOCK
<br />ROOMS AND ELEC. EQUIP. ROOMS TO EXTERIOR (EXCEPT LABELED DOORS; SEE
<br />B-1)
<br />3 EA. HINGES BB1279 OR TA2714 4.5 X 4.5 NRP X USP
<br />1 EA. ALARMED EXIT DEVICE V40XEHX626
<br />0 CYLINDER FOR ALARM (FURNISHED AND INSTALLED BY PUBLIX)
<br />1 EA. LATCH PROTECTOR MLP 211 SL
<br />1 EA. CLOSER W/STOP, H.O. 1431 PS TB
<br />1 EA. ONE WAY VIEWER 622 X CRM
<br />1 EA. THRESHOLD 2005 AV
<br />1 SET WEATHER-STRIP S88D
<br />1 EA. DOOR SWEEP PEMKO 57AV
<br />1 EA. RAINGUARD 346C (FOR RAISER ROOM)
<br />3.8.3 GROUP A-1 B
<br />DOUBLE DOOR EXIT (PANIC BAR, EXIT ONLY), WITH ALARM, CLOSER W/H.O.;
<br />DOORS FROM STOCK ROOMS TO EXTERIOR
<br />8 EA. HINGES HAGER BB1191 4.5 X 4.5 NRP US32D
<br />2 EA. SURFACE BOLTS SARGENT # 988
<br />1 EA. SURFACE VERTICAL ROD DEVICE SARGENT HC4-8710 (NO TRIM, EXIT ONLY)
<br />1 EA. CLOSER NORTON 7500H ON PULL SIDE OF ACTIVE DOOR
<br />1 EA. BOTTOM LATCH GUARD ROCKWOOD BFLG12
<br />1 EA. ROD GUARD ROCKWOOD BFRC24
<br />1 EA. ONE WAY VIEWER ROCKWOOD # 622
<br />1 EA. SADDLE THRESHOLD PEMKO 271A-72"
<br />2 EA. DOOR SWEEP PEMKO 57AV-36"
<br />1 EA. PERIMETER GASKET PEMKO S88D
<br />1 SET ASTRAGAL W/S PEMKO 303AS-96"
<br />1 DETEX WALL MOUNTER ALARM WITH DOOR CONTACTS EAX-2500SK
<br />3.8.4 GROUP B-1A
<br />EXIT DOOR (PANIC BAR, EXIT ONLY), WITH ALARM, CLOSER (BUT WITHOUT
<br />H.O. BECAUSE DOOR IS B-LABEL, 60-MIN., OR IS A DIRECT EXIT FROM
<br />SALES AREA)
<br />3 EA. HINGES B81279 OR TA2714 4.5 X 4.5 NRP X USP
<br />1 EA. ALARMED EXIT DEVICE FV40XEHX630
<br />0 CYLINDER FOR ALARM (FURNISHED AND INSTALLED BY PUBLIX)
<br />1 EA. CLOSER W/STOP, W/O H.O. 1431 PS TB
<br />1 EA. LATCH PROTECTOR MLP 211 SL
<br />1 EA. DOOR SWEEP PEMKO 57AV
<br />1 EA. THRESHOLD 2005 AV
<br />1 SET WEATHER-STRIP S88D
<br />1 EA. ONE WAY VIEWER 622 X CRM
<br />3.8.5 GROUP B-113
<br />DOUBLE DOOR EXIT (PANIC BAR, EXIT ONLY), WITH ALARM, CLOSER (BUT
<br />WITHOUT H.O. BECAUSE DOOR IS B-LABEL, 60-MIN., OR IS A DIRECT EXIT
<br />FROM SALES AREA)
<br />6 EA. HINGES BB1279 4.5 X 4.5 NRP USP
<br />1 EA. MULLION YALE M200FWS 7'
<br />2 EA. ALARMED EXIT DEVICE FHV40 EH 628
<br />2 EA.CLOSER 1431 PS EN
<br />1 EA.THRESHOLD PEMKO 2005AV X 72"
<br />2 EA.DOOR SWEEP PEMKO 57AV X 36"
<br />2 EA.W/S GASKET PEMKO S88D X 17'
<br />1SET - ASTRAGAL WEATHER STRIP PEMKO 303AS X 84"
<br />1 EA. DOOR VIEWER ROCKWOOD #622 US26D
<br />3.8.6 GROUP B-2
<br />EXIT ACCESS DOOR (PANIC BAR), NO ALARM, INTO RATED CORRIDOR, W/CLOSER
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. EXIT DEVICE W/LEVER OUT 12-8813 F ETL X 32D
<br />1 EA. CLOSER 1431 UO TB
<br />1 EA. SMOKE SEALS88D
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3.8.7 GROUP B-3
<br />DOORS INTO RATED CORRIDOR, ELECTROMAGNETIC HOLD -OPEN, PANIC BAR
<br />ON ONE SIDE FOR IMPACT RESISTANCE, SWING -CLEAR HING SES
<br />3 EA. HINGES BB1262 X 4.5 (SWING CLEAR)
<br />1 EA. EXIT DEVICE W/LEVER OUT AL-12-8813 F ETL X 32D
<br />1 EA. CLOSER 1431 UO TB
<br />1 EA. ELECTROMAGNETIC HOLDER 997 X AL X 24 VOLT
<br />3.8.8 GROUP C-1
<br />EXIT DOOR (PANIC BAR), NO ALARM, FROM RATED ENCLOSURE WHICH HAS
<br />NO OTHER TRAFFIC, W/CLOSER (OCCURS ONLY IN REMODELS AND NEW
<br />STORES WHICH REQUIRE AN ADDED RATED EXIT CORRIDOR DUE TO
<br />ADJACENT BUILDINGS)
<br />3 EA. HINGES TA2714 4.5 X 4.5 NRP X USP
<br />1 EA. EXIT DEVICE 12-8813 F X 32D
<br />1 EA. CLOSER, W/STOP, W/O H.O. 1431 PS TB
<br />1 EA. DOOR SWEEP PEMKO 57AV
<br />1 EA. THRESHOLD 2005 AV
<br />1 SET WEATHER-STRIP S88D
<br />3.8.9 GROUP C-2
<br />EXIT ACCESS DOOR (PANIC BAR), WITH ALARM, INTO RATED ENCLOSURE
<br />WHICH HAS NO OTHER TRAFFIC, W/B-LABEL & CLOSER (OCCURS ONLY IN
<br />REMODELS AND NEW STORES
<br />WHICH REQUIRE AN ADDED RATED EXIT CORRIDOR DUE TO ADJACENT BUILDINGS)
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. EXIT DEVICE W/LEVER OUT FV40XEH
<br />0 CYLINDER FOR ALARM (FURNISHED & INSTALLED BY PUBLIX)
<br />1 EA. LATCH PROTECTOR MLP 211 SL
<br />1 EA. CLOSER, W/0 STOP, W/O H.O. 1431 UO TB
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3.8.10 GROUP D
<br />LOCKSET, CAN BE DISABLED FROM INSIDE: OFFICES, BOOKKEEPING
<br />CONFERENCE/ TRAINING ROOMS, STORAGE ROOMS:
<br />3 EA. HINGES 1279 X 4.5 X 4.5
<br />1 EA. ENTRANCE LOCKSET 28 1OGO5 LL
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3 EA. SILENCERS 608
<br />3.8.11 GROUP D- 1
<br />LOCKSET, CAN BE DISABLED FROM INSIDE: SINGLE TOILETS:
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. ENTRANCE LOCKSET 10G44 LL
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />1 EA. CLOSER 1431 UO TB
<br />3 EA. SILENCERS 608
<br />3.8.12 GROUP E
<br />LOCKSET, CAN BE DISABLED FROM INSIDE, WITH CLOSER: DOORS FROM
<br />SALES AREA TO CUSTOMER SERVICE AND OFFICE AREA AND DOOR(S) FROM
<br />ELEC. EQUIP. ROOM TO INTERIOR, SINGLE TOILET RESTROOMS
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. ENTRANCE LOCKSET 10GO5 LL
<br />1 EA. CLOSER 1431 UO TB
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3 EA. SILENCERS 608
<br />3.8.13 GROUP F-1
<br />LOCKSET, KEY -OPERATED ONLY: (SINGLE) EQUIPMENT CLOSET DOORS
<br />3 EA. HINGES 1279 X 4.5 X 4.5
<br />1 EA. STOREROOM LOCKSET 10GO4 LL
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3 EA. SILENCERS 608
<br />3.8.14 GROUP F-2
<br />LOCKSET, KEY -OPERATED ONLY: PAIRS OF EQUIPMENT CLOSET DOORS
<br />6 EA. HINGES 1279 X 4.5 X 4.5
<br />1 EA. STOREROOM LOCKSET 10GO4 LL
<br />2 EA, DOOR STOPS 409 OR 443 AS REQUIRED
<br />1 PAIR FLUSH BOLTS555 X 12"
<br />1 EA. DUST PROOF STRIKE 570
<br />2 EA. SILENCERS 608
<br />3.8.15 GROUP G
<br />LOCKSET, KEY -OPERATED ONLY, WITH CLOSER: CASH ROOM
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. STOREROOM LOCKSET 10G04 LL
<br />1 EA. CLOSER 1431 UO TB
<br />1 EA.DOOR STOP 409 OR 443 AS REQUIRED
<br />1 EA. LARGE DOOR VIEWER DS2000 BY DOOR SCOPE, SILVER FINISH
<br />3 EA. SILENCERS 608
<br />3.8.16 GROUP H
<br />OFFICE SET: HALF DOOR AT PHARMACY
<br />3 EA. HINGES 1279 X 4.5 X 4.5
<br />1 EA. LOCKSET 10G04 LL
<br />2 EA. FOLDING BRACKETS EB-303/EP TB (SUGATSUNE AMERICA)
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />2 EA. SILENCERS 608
<br />3.8.17 GROUP J
<br />PASSAGE SET: NON -LOCKING STORAGE & EQUIPMENT, PASSAGE DOORS
<br />3 EA. HINGES 1279 X 4.5 X 4.5 X 26D
<br />1 EA. PASSAGE SET 1OU15
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3 EA. SILENCERS 608
<br />3.8.18 GROUP K
<br />RESTROOMS, PASSAGE DOOR IN OFFICE AREA
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. PUSH PLATE 70 F 8 X 16 X 32D
<br />1 EA. DOOR PULL 107X 70 C 4 X 16 X 32D
<br />1 EA. CLOSER 1431 UO TB
<br />1 EA. KICK PLATE K1062 8 X 34, US32D
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3 EA. SILENCERS 608
<br />3.8.19 GROUP L-1
<br />VERTICAL LIFT DOORS
<br />2 EA. PADLOCKS (1 DAYLOCK, 1 NIGHTLOCK)758C-4
<br />3.8.20 GROUP L-2
<br />ROOF HATCH, EQUIPMENT CAGES, TRASH COMPACTOR
<br />1 EA. PADLOCK 758C-4
<br />3.8.21 GROUP M
<br />ROOF TOP EQUIPMENT ROOMS
<br />3 EA. HINGES 1270 X 4.5 X 4.5 X USP X NRP
<br />1 EA. DEADLOCK 484 X 26
<br />1 EA. DOORPULL 8102-6S 32D
<br />1 EA. STOP & H.O. GJ90M X 26D
<br />3.8.22 GROUP N
<br />3.8.23 FRONT DOORS, EXTERIOR CAFE DOORS (STOREFRONT)
<br />USE STANDARD MORTISE OR RIMSET CYLINDERS SUPPLIED WITH STORE
<br />FRONT DOORS AS CONSTRUCTION TEMPORARIES. PERMANENT CYLINDERS
<br />FURNISHED & INSTALLED BY PUBLIX. ALL OTHER HARDWARE BY DOOR
<br />MANUFACTURER.
<br />3.8.24 GROUP P
<br />PHARMACY ROLLING GRILLE
<br />PREPARE FOR SCHLAGE MORTISE CYLINDER, CYLINDER FURNISHED AND INSTALLED
<br />BY
<br />PUBLIX.
<br />3.8.25 GROUP Q
<br />RETURN AIR CHASE ACCESS DOORS BY MILCOR OR NYSTROM
<br />PREPARE FOR SCHLAGE MORTISE CYLINDER, CYLINDER FURNISHED AND INSTALLED
<br />BY
<br />PUBLIX.
<br />3.8.26 GROUP R
<br />EXTERIOR STORAGE OR MECHANICAL ROOMS
<br />6 EA. HINGES BB 1191 OR TA2314 4.5 X 4.5 NRP X USP
<br />1 EA. LOCKSET 10GO4 LL
<br />1 EA. SURFACE BOLTS 988
<br />2 EA. OVERHEAD HOLDER 598H
<br />1 SET WEATHERSTRIPS88D LAIR
<br />1 EA. THRESHOLD 2005 AS LAR
<br />2 EA. MEETING STILE ASTRAGAL 303 AS
<br />3.8.27 GROUP S
<br />LOCKSET, CAN BE DISABLED FROM INSIDE, WITH CLOSER: DOORS FROM CLINICAL
<br />ROOM OR
<br />OFFICE TO INTERIOR OF PHARMACY
<br />3 EA. HINGES BB1279 X 4.5 X 4.5
<br />1 EA. ENTRANCE LOCKSET SIMPLEX L1000 PUSHBUTTON
<br />1 EA. CLOSER 1431 UO TB
<br />1 EA. DOOR STOP 409 OR 443 AS REQUIRED
<br />3 EA. SILENCERS 608
<br />3.8.28 GROUP T
<br />RESTROOMS WITH WALL PARTITIONS (WHERE APPLICABLE)
<br />3 EA. HINGES TA2714 4.5 X 4.5 NRP X USP
<br />1 EA. DEADBOLT 8571 626
<br />1 EA. PUSH PLATE 70A US32D CFTT
<br />1 EA. CLOSER 1431 UO TB (ADA STALL ONLY)
<br />1 EA. DOOR PULL 132-RKW MTG-TYPE 2 US32D
<br />1 EA, DOOR STOP 1513 CP
<br />3.8.29 GROUP U
<br />STORE FRONT DOOR TO THE EXTERIOR.
<br />THE FOLLOWING ITEMS ARE TO BE INCLUDED WITH THE DOOR AND PROVIDED
<br />BY THE STORE FRONT DOOR PROVIDER:
<br />1 EA. DOOR CLOSER
<br />1 EA. DOOR PULL
<br />1 EA. PUSH BAR
<br />1 EA. THUMB TURN
<br />End of Section 08 71 00
<br />SECTION 09 29 00
<br />GYPSUM BOARD
<br />V01212016
<br />1. GENERAL
<br />1.1. SUBMIT LOIS IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL PROCEDURES.
<br />2. PRODUCTS
<br />2.1. MANUFACTURER: ALL MATERIALS SHALL BE PRODUCTS OF ONE MANUFACTURER,
<br />EXCLUDING CEMENTITIOUS BACKER BOARD WHEN NECESSARY.
<br />2.2. MATERIALS:
<br />2.2.1 ALL BOARD TYPES SHALL BE 5/8" THICKNESS, UNLESS INDICATED OTHERWISE.
<br />2.2.2 COORDINATE PLACEMENT OF GYPSUM BOARD TYPES WITH ROOM FINISH
<br />SCHEDULE AND WALL TYPE DESIGNATIONS.
<br />2.2.3 DRYWALL:
<br />2.2.3.1 FIRE RETARDANT DRYWALL: ASTM C36, TYPE X.
<br />12.2.3.2 GYPSUM TILE BACKER BOARD: ASTM D 3273. SEE ROOM FINISH
<br />SCHEDULE FOR LOCATIONS.
<br />2.2.3.3 MANUFACTURERS: GEORGIA-PACIFIC CORP.
<br />NATIONAL GYPSUM CO.
<br />TEMPLE -INLAND FOREST PRODUCTS CORP.
<br />US GYPSUM CO.
<br />2.2.4 CEMENTITIOUS TILE BACKER BOARD: ASTM C 1178. USE ONLY WHERE
<br />DESIGNATED IN THE ROOM FINISH SCHEDULE.
<br />2.2.4.1 MANUFACTURERS:
<br />US GYPSUM CO., DUROCK CEMENT BOARD
<br />JAMES HARDIE CO., HARDIBACKER 500
<br />CUSTOM BUILDING PRODUCTS, WONDERBOARD
<br />NATIONAL GYPSUM CO., PERMABASE CEMENT BOARD
<br />2.2.5 ACCESSORIES:
<br />2.2.5.1 JOINT REINFORCING TAPE SHALL BE PERFORATED OR SPARKED.
<br />JOINT COMPOUND SHALL BE READY MIXED.
<br />2.2.5.2 CORNER BEADS, CASING BEADS AND TRIM SHALL BE GALVANIZED STEEL.
<br />2.2.6 DRYWALL CEILING SUSPENSION SYSTEM: PROVIDE PRE-ENGINEERED
<br />SYSTEM CONSISTING OF COLD -ROLLED STEEL MEMBERS CONFORMING TO
<br />ASTM C635. PROVIDE FIRE -RATED ASSEMBLIES WHEN APPLICABLE.
<br />2.2.6.1 PRODUCTS:
<br />"DRYWALL SUSPENSION SYSTEM", USG "DRYWALL GRID
<br />SYSTEM", ARMSTRONG
<br />"DRYWALL GRID SYSTEM 640/66011, CHICAGO METALLIC
<br />2.2.7 STEEL STUDS:
<br />2.2.7.1 GALVANIZED SCREWABLE CHANNEL TYPE STUDS OF SPECIFIED SIZE,
<br />COMPLYING WITH ASTM C645, 20 GAUGE MINIMUM (OR EQUIVALENT FOR
<br />KNURLED STEEL), AT ALL INTERIOR LOCATIONS.
<br />2.2.7.2 MANUFACTURER:
<br />MARINO\WARE-DIV.WARE INDUSTRIES
<br />DIETRICH INDUSTRIES
<br />CLARK STEEL FRAMING SYSTEMS
<br />TELLING INDUSTRIES
<br />ALLSTEEL & GYPSUM PRODUCTS
<br />STEEL CON
<br />2.2.7.3 FORM FROM STEEL ASTM A653, GRADE A, WITH A MINIMUM YIELD OF
<br />33,000 PSI.
<br />2.2.8 DRYWALL SCREWS: ASTM C645.
<br />2.3. BACKING FOR DRYWALL AT OUTSIDE CURVE APPLICATIONS: A-C INT-APA WITH
<br />EXTERIOR GLUE, 1/8" THICKNESS.
<br />3. EXECUTION
<br />3.1. CEILING
<br />3.1.1 INSTALL WALL TRACK LEVEL AT SPECIFIED CEILING HEIGHT AROUND ENTIRE
<br />PERIMETER.
<br />3.1.2 FURRING RUNNERS SHALL BE DIRECTLY SUSPENDED AND LEVELED ON
<br />48" CENTERS BY NOT LESS THAN 12 GAUGE GALVANIZED STEEL WIRE
<br />SPACED NOT MORE THAN 48" ON CENTER ALONG THE MAIN RUNNER. (FOR
<br />SPECIAL MODULE SIZES FOLLOW SAME PROCEDURES WITH ON CENTER
<br />SPACING OF RUNNERS ADJUSTED TO TEE WIDTH.)
<br />3.1.3 FURRING TEES SHALL BE SPACED 16" ON CENTER ALONG THE MAIN
<br />RUNNERS.
<br />3.1.4 FIT FURRING RUNNER AND TEE ENDS INTO THE WALL TRACK AT ALL
<br />PERIMETERS.
<br />3.1.5 DRYWALL PANELS SHALL BE SCREW ATTACHED AT 8" INTERVALS TO ALL
<br />FURRING RUNNERS, TEES, AND WALL TRACK WITH THE LONG DIMENSION
<br />PARALLELING THE FURRING RUNNERS IN ALL POSSIBLE INSTANCES.
<br />DEFLECTION OF COMPONENTS NOT TO EXCEED 1/360 OF THE SPAN.
<br />3.1.6 IN AREAS WHERE FIXTURES OR OTHER ACCESSORIES ARE PLACED IN
<br />OR ON THE GRID COMPONENTS, 12 GAUGE HANGER WIRES ARE TO BE
<br />SUSPENDED AT EACH CORNER OF THE FIXTURE OR ACCESSORY TO
<br />DISTRIBUTE THE LOAD EVENLY.
<br />3.2. WALLS
<br />3.2.1 STEEL STUDS: 16" ON CENTER.
<br />3.2.2 PANELS SHALL BE SCREWED TO STEEL STUDS WITH BUGLE HEAD DRY
<br />WALL SCREWS OF LENGTH AS RECOMMENDED BY MANUFACTURER.
<br />3.2.3 WHERE APPLICABLE, INSULATE WALLS AROUND MEAT CUTTING, PACKAGING
<br />ROOM, EMPLOYEE LOUNGE, MANAGER'S OFFICE, REST ROOMS AND AS
<br />INDICATED ON DRAWINGS WITH 3 1-211 BATT INSULATION.
<br />3.2.4 AXIALLY LOADED STUDS SHALL BE INSTALLED IN A MANNER WHICH WILL
<br />ASSURE THAT ENDS OF THE STUDS ARE POSITIONED AGAINST THE INSIDE
<br />TRACK WEB, PRIOR TO STUD AND TRACK ATTACHMENT.
<br />3.2.5 STUDS SHALL BE PLUMBED, ALIGNED AND SECURELY ATTACHED TO THE
<br />FLANGES OR WEBS OF BOTH UPPER AND LOWER TRACKS.
<br />3.2.6 JACK STUDS OR CRIPPLES SHALL BE INSTALLED ABOVE WINDOW AND
<br />DOOR HEADS, AT FREE STANDING STAIR RAILS, AND ELSEWHERE TO
<br />FURNISH SUPPORT, AND SHALL BE SECURELY ATTACHED TO SUPPORTING
<br />MEMBERS.
<br />3.2.7 WALL STUD BRIDGING SHALL BE ATTACHED IN A MANNER TO PREVENT STUD
<br />ROTATION. BRIDGING ROWS SHALL BE SPACED ACCORDING TO THE FOLLOWING
<br />SCHEDULE:
<br />WALLS UP TO 10' 0" HEIGHT: ONE ROW AT MID -HEIGHT; WALLS EXCEEDING 10'-099:
<br />BRIDGING ROWS SPACED NOT TO EXCEED 5'-0" ON -CENTER.
<br />3.2.8 PROVIDE 7/8" 20 GAUGE GALVANIZED STEEL DRYWALL FURRING CHANNELS
<br />VERTICALLY AT 16" O.A. FOR ALL PANELED WALLS ON MASONRY AND OTHERS AS
<br />REQUIRED.
<br />3.2.9 FOR ALL WALLS THAT SURROUND FLOORS THAT WILL RECEIVE
<br />PORTLAND CEMENT TERRAZZO, LEAVE OUT THE FIRST 4 FEET OF GYPSUM
<br />BOARD (FROM FINISH FLOOR) UNTIL TERRAZZO INSTALLATION IS COMPLETE.
<br />3.3. WALLS AND CEILINGS
<br />3.3.1 STEEL STUD FRAMING COMPONENTS MAY BE PRE -ASSEMBLED INTO
<br />PANELS PRIOR TO ERECTING. PREFABRICATED PANELS SHALL BE SQUARE
<br />WITH COMPONENTS ATTACHED IN A MANNER AS TO PREVENT RACKING.
<br />3.3.2 ALL FRAMING COMPONENTS SHALL BE SET SQUARELY FOR ATTACHMENT
<br />TO PERPENDICULAR MEMBERS, OR AS REQUIRED FOR AN ANGULAR FIT
<br />AGAINST ABUTTING MEMBERS. MEMBERS SHALL BE HELD POSITIVELY IN
<br />PLACE UNTIL PROPERLY FASTENED.
<br />3.3.3 A UNIFORMLY THIN LAYER OF JOINT COMPOUND SHALL BE APPLIED OVER
<br />JOINTS TO A WIDTH OF APPROXIMATELY 4" WIDE. CENTER TAPE OVER JOINT
<br />AND IMBED INTO COMPOUND LEAVING SUFFICIENT JOINT COMPOUND UNDER
<br />TAPE TO PROVIDE PER BOND. CEILING AND WALL ANGLES AND INSIDE
<br />CORNER ANGLES SHALL BE REINFORCED WITH TAPE FOLDED TO CONFORM TO
<br />THE ANGLE AND IMBEDDED IN THE COMPOUND.
<br />3.3.4 SAND BETWEEN COATS.
<br />3.3.5 AFTER COMPOUND IS THOROUGHLY DRY, THE TAPE SHALL BE COVERED
<br />WITH ANOTHER COAT OF JOINT COMPOUND SPREAD OVER THE TAPE AND
<br />3" EACH SIDE OF TAPE, AND FEATHERED OUT AT EDGE. AFTER THOROUGHLY
<br />DRY, APPLY ANOTHER COAT WITH SLIGHT, UNIFORM CROWN
<br />OVER THE JOINT. THIS COAT SHALL BE SMOOTH WITH EDGES FEATHERED
<br />APPROXIMATELY 3"
<br />BEYOND PRECEDING COAT.
<br />3.3.6 COAT CORNERS, AND NAIL OR SCREW HEADS ADDITIONALLY AS PER
<br />MANUFACTURERS SPECIFICATIONS.
<br />3.3.7 INSTALL J-MOLD AT CEILING AND WALL JUNCTURE WHERE REQUIRED.
<br />3.3.8 ENTIRE AREAS SHALL BE INSTALLED NEATLY AND READY TO RECEIVE
<br />FINISH AS SCHEDULED. ALL STUDS SHALL HAVE DRYWALL TO THE TOP OF
<br />THE PLATE FOR FIRE AND RODENT PROTECTION.
<br />3.3.9 PRIOR TO INSTALLATION, PROVIDE REPRESENTATIVE SAMPLE OF
<br />"KNOCK -DOWN" FINISH TO THE PUBLIX CONSTRUCTION REPRESENTATIVE.
<br />3.3.10 CONTROL JOINTS: IN CEILING, INSTALL EXPANDABLE CONTROL JOINTS AS
<br />RECOMMENDED BY MANUFACTURER, AT MAXIMUM 40' ON CENTER.
<br />3.4. MOISTURE RESISTANT GYPSUM BOARD:
<br />3.4.1 USE AT LOCATIONS INDICATED IN THE ROOM FINISH SCHEDULE.
<br />3.4.2 USE BEHIND ALL REFRIGERATED CASES TO A HEIGHT OF 4'-01 /2".
<br />START AT 1 /2" ABOVE FINISHED FLOOR.
<br />3.4.3 INSTALL ADJACENT TO ALL WALK-IN COOLERS AND FREEZERS. HEIGHT:
<br />ABOVE THE TOP OF THE UNIT.
<br />3.4.4 USE AT OTHER LOCATIONS AS REQUIRED.
<br />3.5. CURVED SUSPENDED WALLS:
<br />3.5.1 OUTSIDE CURVES 10'-0" RADIUS OR LESS: FORM CURVE WITH METAL
<br />STUDS 8" OC BEGINNING 2'-0" INTO STRAIGHT PORTION OF WALL.
<br />THOROUGHLY SOAK AND APPLY TWO LAYERS 1/8" PLYWOOD TO METAL
<br />STUDS ALLOWING FIRST LAYER TO DRY BEFORE APPLICATION OF SECOND.
<br />APPLY 1 /4" DRYWALL TO PLYWOOD SUBSTRATE WITH DRYWALL ADHESIVE,
<br />LONG DIMENSION HORIZONTAL. WET DRYWALL AS NECESSARY TO OBTAIN
<br />SMOOTH CURVE WITH NO FLATS.
<br />3.5.2 OUTSIDE CURVES RADIUS GREATER THAN 10'-0": FORM CURVE WITH
<br />METAL STUDS 8" OC BEGINNING 2'-0" INTO STRAIGHT PORTION OF WALL.
<br />APPLY 1 /2" DRYWALL TO METAL STUDS WITH DRYWALL ADHESIVE, LONG
<br />DIMENSION HORIZONTAL. WET DRYWALL AS NECESSARY TO OBTAIN SMOOTH
<br />CURVE WITH NO FLATS.
<br />3.5.3 INSIDE CURVES RADIUS GREATER THAN 10'-0": FORM CURVE WITH
<br />METAL STUDS 1'-O" OC BEGINNING 2'-0" INTO STRAIGHT PORTION OF
<br />WALL. APPLY 1 /2" DRYWALL TO METAL STUDS WITH DRYWALL ADHESIVE,
<br />LONG DIMENSION HORIZONTAL. WET DRYWALL AS NECESSARY TO OBTAIN
<br />SMOOTH CURVE WITH NO FLATS.
<br />END OF SECTION 09 29 00
<br />SECTION 09 30 00
<br />TILING
<br />VO1212016
<br />1. GENERAL
<br />1.1. THIS SECTION ALSO CONTAINS INFORMATION NORMALLY FOUND IN SECTION 04 40
<br />00 STONE
<br />ASSEMBLIES PERTAINING TO MARBLE AND GRANITE SILLS.
<br />1.2. SUBMITTALS:
<br />1.2.1 SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL
<br />PROCEDURES.
<br />1.2.2 PRODUCT LITERATURE FOR ALL ITEMS SELECTED IN L01 ARE REQUIRED WITH
<br />SUBMISSION.
<br />1.3. WARRANTIES: ALL TILE WORK SHALL BE GUARANTEED FOR WORKMANSHIP FOR A
<br />PERIOD OF TWO (2) YEARS. ANY WORK FOUND TO BE DEFECTIVE DURING THAT
<br />TIME SHALL BE REPLACED AT NO COST TO THE OWNER.
<br />2. PRODUCTS
<br />2.1. CERAMIC TILE WALLS AND WAINSCOTS: MANUFACTURER, SERIES, FINISH, COLOR,
<br />AND SIZE AS INDICATED ON INTERIOR FINISH ELEVATIONS.
<br />2.1.1 TILE PATTERNS ARE CONTAINED IN THE TILE PATTERN BOOK, WHICH IS AVAILABLE
<br />AT HTTPS:/
<br />/APP.BOX. COM/S/OCJP4UMWKDF54WEQ66UD
<br />2.1.2 CERAMIC TILE SETTING AND GROUTING COMPOUNDS: SELECT EITHER
<br />LATICRETE OR MAPEI FOR ALL APPLICATIONS (USE OF THE TWO APPROVED
<br />PRODUCTS AS A COMBINATION IS NOT ALLOWED)
<br />2.1.3 LATICRETE PRODUCTS:
<br />2.1.3.1 LATICRETE 252 SILVER THINSET ADHESIVE (QUARRY TILE FLOORS)
<br />2.1.3.2 LATICRETE SPECTRA LOCK 2000 IC GROUT (QUARRY TILE FLOORS)
<br />2.1.3.3 LATICRETE 4XLT MORTAR (ADHESIVE FOR WALL LARGER TILE)
<br />2.1.3.4 LATICRETE 252 SILVER THINSET (ADHESIVE FOR WALL NOMINAL TILE)
<br />2.1.3.5 LATICRETE PERMACOLOR SERIES GROUT (WALLS)
<br />2.1.4 MAPEI PRODUCTS
<br />2.1.4.1 ULTRAFLEX 3 THINSET ADHESIVE (QUARRY TILE FLOORS)
<br />2.1.4.2 KERAPDXY IEG GROUT (QUARRY TILE FLOORS)
<br />2.1.4.3 ULTRAFLEX THINSET ADHESIVE (FOR ALL WALLS TILES)
<br />2.1.4.4 ULTRACOLOR SERIES GROUT (WALLS)
<br />2.1.5 GROUT COLORS: SEE TILE PATTERN BOOK.
<br />2.2. GROUT RELEASE AGENT:
<br />AQUA MIX GROUT RELEASE, AQUA MIX
<br />2.3. SEALANTS: ONE OR TWO PART URETHANE. USE TYPE DESIGNED FOR APPLICATION
<br />INTENDED, COLOR AS SELECTED BY ARCHITECT.
<br />2.4. WHERE THE FLOOR SLAB IS ELEVATED ABOVE GROUND SELECT FROM THE
<br />FOLLOWING WATERPROOF MEMBRANE PRODUCTS:
<br />2.4.1 LATICRETE PRODUCT:
<br />2.4.1.1 LATICRETE HYDRO BARRIER
<br />2.4.2 MAPEI PRODUCTS:
<br />2.4.2.1 MAPELASTIC AQUADEFENSE
<br />2.4.2.2 MAPELASTIC 315
<br />3. EXECUTION
<br />3.1. GENERAL: ALL APPLICATORS AND FIELD PERSONNEL SHALL BE FULLY TRAINED AND
<br />FAMILIAR WITH MANUFACTURERS' APPLICATION PROCEDURES.
<br />3.2. QUARRY TILE AND BASE:
<br />3.2.1 LAY TILE IN A STRAIGHT JOINT PATTERN, EACH DIRECTION, WITH A
<br />1/4" JOINT. ALIGN FLOOR AND BASE JOINTS. SEE ROOM FINISH SCHEDULE
<br />AND FINISH ELEVATIONS FOR LOCATIONS OF QUARRY TILE BASE.
<br />3.2.2 APPLY GROUT RELEASE AGENT PER MANUFACTURER'S INSTRUCTIONS
<br />PRIOR TO INSTALLING GROUT.
<br />3.2.3 GROUT SHALL BE LEVEL WITH THE SURFACE OF THE TILE, WITH NO
<br />SHARP EDGES OF THE TILE SHOWING.
<br />3.2.4 CUT QUARRY TILE AS REQUIRED TO PROVIDE A 1 /4" CONTROL JOINT
<br />DIRECTLY ABOVE SLAB CONSTRUCTION JOINTS. PRIME SIDES OF JOINT
<br />WIDTH. SEAL CONTROL JOINT WITH POLYURETHANE SEALANT TO
<br />1/4" DEPTH, BACKED WITH CLOSED -CELL FOAM.
<br />3.2.5 SLOPE ALL TILE TO DRAINS, AS SHOWN ON DRAWINGS. SET ALL TILE
<br />FLUSH WITH TOPS OF FLOOR DRAINS AND ADJACENT FINISHED FLOORS.
<br />3.2.6 ENSURE THAT BASE HAS A SOLID GROUT BED WHERE IT MAKES CONTACT
<br />WITH THE WALL, AND THAT THERE ARE NO VOID AREAS BEHIND TILE AND AT
<br />TRANSITION WITH FLOOR.
<br />3.3. MARBLE OR GRANITE SILLS
<br />3.3.1 SET BY EXPERIENCED GRANITE CRAFTSMEN WHO HAVE A MINIMUM OF
<br />THREE (3) YEARS EXPERIENCE IN THE TRADE, AND IN ACCORDANCE WITH
<br />THE MARBLE INSTITUTE OF AMERICA (M.I.A.) INSTALLATION PROCEDURES
<br />MANUAL.
<br />3.3.2 SEAL JOINTS WITH APPROPRIATE SEALANT.
<br />3.3.3 COORDINATE AND COOPERATE WITH STORE FRONT SASH INSTALLER.
<br />3.4. CERAMIC WALL TILE ON MASONRY SUBSTRATE
<br />3.4.1 THIN -SET WITH MORTAR AND UN -SANDED GROUT, BOTH IN
<br />ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND
<br />RECOMMENDATIONS.
<br />3.4.2 SET FLUSH WITH ADJACENT BASE; LAY IN A STRAIGHT JOINT PATTERN
<br />EACH DIRECTION, WITH A JOINT WIDTH OF 1/16" OR AS ESTABLISHED BY
<br />MANUFACTURER'S SHEET.
<br />3.4.3 GROUT SHALL BE LEVEL WITH THE SURFACE OF THE TILE, WITH NO
<br />SHARP EDGES OF THE TILE SHOWING.
<br />3.5. CERAMIC TILE ON BACKER BOARD
<br />3.5.1 SET ON MOISTURE -RESISTANT BACKER BOARD WITH MORTAR, GROUT WITH
<br />UNSANDED CEMENT GROUT, BOTH IN ACCORDANCE WITH MANUFACTURER'S
<br />SPECIFICATIONS AND RECOMMENDATIONS.
<br />3.5.2 SET FLUSH WITH ADJACENT BASE; LAY IN A STRAIGHT JOINT PATTERN
<br />EACH DIRECTION, WITH A JOINT WIDTH OF 1/16" OR AS ESTABLISHED BY
<br />MANUFACTURER'S TILE SHEET.
<br />3.5.3 GROUT SHALL BE LEVEL WITH THE SURFACE OF THE TILE, WITH NO
<br />SHARP EDGES OF THE TILE SHOWING.
<br />3.6. EXTERIOR CERAMIC TILE: IF THIS PROJECT IS TO RECEIVE EXTERIOR TILE SET ON A
<br />VERTICAL SURFACE (SEE CONTRACT DOCUMENTS BY OTHERS FOR STORE FACADE),
<br />THE TILE, SETTING METHOD, PATTERN, AND GROUT SHALL BE APPROVED IN WRITING
<br />BY PUBLIX' ARCHITECT.
<br />END OF SECTION 09 30 00
<br />SECTION 09 50 00
<br />CEILINGS
<br />V01062015
<br />1. GENERAL
<br />1.1. SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL PROCEDURES. NO
<br />PRODUCT SAMPLES OR CUT SHEETS WILL BE REQUIRED.
<br />1.2. CUSTOM COLORS: WHERE CUSTOM COLORS OF CEILING PANELS ARE SPECIFIED, IT
<br />IS ASSUMED THAT THE QUANTITY REQUIRED FOR USE WILL EXCEED THE AMOUNT
<br />OF MATERIAL NEEDED FOR A STOCK RUN BY PANEL MANUFACTURER. IF THIS
<br />CONDITION IS NOT MET, AND THERE IS AN UP -CHARGE FOR CUSTOM COLORS,
<br />NOTIFY PUBLIX ARCHITECT.
<br />2. PRODUCTS
<br />2.1. SUSPENSION SYSTEMS:
<br />2.1.1 WHERE CEILING PANELS ARE USED:15/16" EXPOSED DOUBLE -WEB TEE
<br />CONFORMING TO ASTM C635 INTERMEDIATE -DUTY CLASSIFICATION
<br />STANDARDS. CROSS -TEES SHALL ALSO COMPLY WITH INTERMEDIATE -DUTY
<br />(12 LB/LF) STANDARDS, AND SHALL HAVE STAB -TYPE STEPPED (I.E.
<br />OVERRIDING) ENDS.
<br />2.1.2 WALL MOLDING SHALL BE ANGLE WITH 7/8" LEGS. SYSTEM COLOR SHALL BE
<br />FLAT WHITE.
<br />2.1.3 ACCEPTABLE SYSTEMS:
<br />ARMSTRONG PRELUDE 15/16" EXPOSED TEE SYSTEM, ALUMINUM CAPS
<br />AND STEPPED END CROSS TEES.
<br />CHICAGO METALLIC CORP. "200 SNAP -GRID SYSTEM", ALUMINUM CAPS
<br />AND STEPPED END CROSS TEES.
<br />USG INTERIORS, INC. DONN DXLA ALUMINUM CAPS AND STEPPED END
<br />CROSS TEES.
<br />2.2. GRID SYSTEM:
<br />2.2.1 SYSTEM DESCRIPTION: UPPER GRID AND LOWER GRID WITH KNUCKLE
<br />ASSEMBLY AND OTHER COMPONENTS TO FORM "CRISS CROSS GRID." UPPER
<br />AND LOWER GRID FORM 6' (NOMINAL) SQUARES. AT SELECT LOCATIONS, 6'
<br />SQUARES ARE DIVIDED INTO 2' SQUARES FOR SUSPENSION OF CEILING TILE
<br />OR OPEN CELL PANELS.
<br />2.2.2 ALL GRID SYSTEM COMPONENTS: LITELAB SYSTEM FURNISHED BY PUBLIX
<br />(O.F.C.I.)
<br />2.2.3 ALL SUSPENSION SYSTEM COMPONENTS ARE A PART OF THE CONTRACT.
<br />SEE THE DRAWINGS FOR DEMARCATION OF GRID SYSTEM AND SUSPENSION
<br />SYSTEM.
<br />2.2.4 CEILING TILE/OPEN-CELL SUB -SYSTEM (REMODELS ONLY):
<br />2.2.4.1 SUB -SYSTEM DESCRIPTION: 6'X 6' COMPOSED OF MAIN TEES AND
<br />CROSS TEES DESCRIBED ABOVE.
<br />2.2.4.2 ALL SUBSYSTEM COMPONENTS ARE A PART OF THE CONTRACT
<br />WITH THE EXCEPTION OF THE DROP -ON T-RAIL WHICH SUPPORTS THE
<br />PERIMETER OF EACH 6'X 6' SUB- SYSTEM.
<br />2.2.4.3 TEE GRID FOR CEILING TILES AND MESH PANELS WITHIN 6'X6'
<br />PANELS: AS ABOVE, COLOR: WHITE.
<br />2.2.4.4 CEILING TILES: VINYL FACED GYPSUM PANELS AS DESCRIBED
<br />BELOW.
<br />2.2.4.5 EDGE TRIM: 8" HIGH X 9/16" LEGS, WITH CONNECTORS FOR GRID
<br />SYSTEM CAPABLE OF RECEIVING INTERSECTING TEES AT ANY ANGLE, AND
<br />SPLICE PLATES TO FORM FLUSH BUTT JOINTS WHERE EDGE TRIM ENDS
<br />MEET. SPLICE PLATES SHALL PROVIDE TIGHT FRICTION FIT OR BE
<br />SECURED WITH SET SCREWS. PAINT ALL SURFACES CUSTOM COLOR AS
<br />SELECTED BY PUBLIX ARCHITECT.
<br />ACCEPTABLE SYSTEMS:
<br />COMPASSO SYSTEM, USG INTERIORS
<br />AXIOM CLASSIC SYSTEM, ARMSTRONG
<br />SUSPENDED PERIMETER TRIM SYSTEM, CHICAGO METALLIC
<br />CONTURA, GORDON ARCHITECTURAL ALUMINUM SPECIALTIES, INC.
<br />2.3. ACOUSTICAL TILE
<br />2.3.1 ACOUSTICAL TILE (SALES AREA) SHALL BE EITHER 2495X 24"X 5/8" OR
<br />24"X 48"X 5/8" (PER DRAWINGS), SQUARE CUT EDGE, WHITE COLOR IN
<br />ONE OF THE FOLLOWING PRODUCTS:
<br />ARMSTRONG FINE FISSURED RH90. CERTAINTEED
<br />HYTONE VANTAGE 10. U.S.G.INTERIORS, INC. RADAR.
<br />2.3.2 VINYL -FACED GYPSUM PANELS (FOOD PREPARATION AREAS - BAKERY,
<br />DELI, AND MEAT INCLUDING ASSOCIATED STORAGE AND SCULLERIES) 249"X
<br />24"X 4891X 1 /2" (PER DRAWINGS) WITH 2-MIL
<br />STIPPLE -PATTERN EMBOSSED WHITE VINYL LAMINATED TO ONE SIDE, SURFACE
<br />BURNING CHARACTERISTICS - CLASS A, AS FOLLOWS:
<br />ARMSTRONG CLEAN ROOM VL
<br />CAPAUL CORP. VINYLROCK GYPSUM CEILING PANELS
<br />CERTAINTEED VINYLTONE GYPSUM PROTECTONE
<br />GOLD BOND BUILDING PRODUCTS GRIDSTONE
<br />USG INTERIORS, INC. SHEETROCK MILLENIA "CLIMAPLUS"
<br />2.4. ACOUSTIC INSULATION: THE ENTIRE AREA ABOVE THE CEILING IN THE MANAGER'S
<br />OFFICE, AND THE PUBLIC AND EMPLOYEES' REST ROOMS SHALL BE INSULATED
<br />WITH 6" GLASS FIBER INSULATION.
<br />2.5. OPENWORK SYSTEMS, UTILITY GRID, AND SPACE FRAME GRID SYSTEM SHOP
<br />FABRICATION AND
<br />FINISHING:
<br />2.5.1 SHOP FABRICATION, GENERAL:
<br />2.5.1.1 PERFORM SHOP FABRICATION TO THE GREATEST EXTENT POSSIBLE.
<br />2.5.1.2 DESIGN OF SYSTEMS SHALL ALLOW ALL WELDING OPERATIONS TO
<br />BE COMPLETED IN THE FABRICATION SHOP.
<br />2.5.1.3 DESIGN OF SYSTEMS SHALL ALLOW INSTALLATION OF UTILITY RUNS
<br />IN A MANNER WHICH PROVIDES A NEAT, FINISHED APPEARANCE.
<br />2.5.2 SHOP PAINTING:
<br />2.5.2.1 APPLY MANUFACTURER'S STANDARD BAKED -ON ENAMEL TO ALL
<br />SURFACES, CUSTOM COLOR AS SELECTED BY PUBLIX ARCHITECT.
<br />2.5.2.2 COAT ALL ACCESSORIES SUCH AS SPLICE PLATES, ETC. TO MATCH EDGE
<br />TRIM COLOR.
<br />2.5.2.3 WRAP OR PACK ALL PAINTED ITEMS TO PROTECT THEM FROM
<br />SCRATCHING OR OTHER DAMAGE DURING SHIPMENT. PROVIDE TEMPORARY
<br />PROTECTION FOR PAINTED
<br />SURFACES (I.E. PEEL -OFF FILM) TO BE REMOVED ONLY AFTER ALL WORK ADJACENT TO
<br />TRIM IS IN PLACE.
<br />3. EXECUTION
<br />3.1. SUSPENSION SYSTEM
<br />3.1.1 THE EXPOSED GRID SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH
<br />ASTM C636.
<br />DEFLECTION OF ANY COMPONENT SHALL NOT EXCEED 1/360 OF THE SPAN.
<br />SUSPENSION SYSTEMS SHALL BE INSTALLED LEVEL AND SQUARE BY
<br />METHODS ACCORDING TO MANUFACTURER'S SPECIFICATION AND FIRMLY
<br />BRACED TO HOLD POSITION AND TO CARRY WEIGHT OF FIXTURES. REFER
<br />TO DRAWINGS.
<br />3.1.2 PERIMETER ANGLE MOLDING SHALL BE INSTALLED AT THE SPECIFIED
<br />CEILING HEIGHT AT THE INTERSECTION OF THE SUSPENDED CEILING AND ALL
<br />VERTICAL SURFACES.
<br />3.1.3 COOPERATE WITH OTHER TRADES AS REQUIRED FOR FIXTURE
<br />INSTALLATION TO SEE THAT PROPER SUPPORT AND SPACING IS OBTAINED.
<br />3.1.4 PROVIDE TWO #10 SAFETY WIRES PER METAL HALIDE AND FLUORESCENT
<br />FIXTURE, ATTACHED TO JOISTS AT PROPER LOCATION AS COORDINATED WITH
<br />ELECTRICAL CONTRACTOR. (ELECTRICAL CONTRACTOR SHALL ATTACH TO
<br />FIXTURE.).
<br />3.2. LAY -IN PANELS
<br />3.2.1 ACOUSTICAL TILE SHALL BE INSTALLED UNDER TEMPERATURE AND
<br />HUMIDITY CONDITIONS CLOSELY APPROXIMATING THOSE WHICH WILL EXIST
<br />WHEN THE BUILDING IS OCCUPIED.
<br />3.2.2 APPLICATION SHALL NOT BEGIN UNTIL ALL ROOFING WORK HAS BEEN
<br />COMPLETED AND BUILDING COMPLETELY ENCLOSED.
<br />3.2.3 ALL WINDOWS AND DOORS SHALL BE IN PLACE AND GLAZED. PLASTERING
<br />AND CONCRETE WORK SHALL BE COMPLETED AND ALLOWED TO DRY BEFORE
<br />THE INSTALLATION OF ACOUSTICAL TILE.
<br />3.2.4 BOARD SHALL BE CAREFULLY FITTED AROUND DIFFUSERS AND OTHER
<br />CEILING OUTLETS AND FIXTURES. COOPERATE WITH SPRINKLER, MECHANICAL
<br />AND ELECTRICAL CONTRACTORS TO COORDINATE WORK.
<br />3.3. FIELD PAINTING
<br />3.3.1 ABOVE THE OPENWORK GRID, WHERE COLOR OF PANELS IS OTHER THAN
<br />WHITE, SPRAY PAINT GRID TO MATCH PANEL COLOR BEFORE PANELS ARE
<br />INSTALLED. USE LINE OF EDGE TRIM OF THE OPENWORK SYSTEM TO
<br />DETERMINE LIMITS OF PAINTING.
<br />3.3.2 IN THE AREA WHERE WHITE PANELS STRADDLE THE LINE OF THE
<br />OPENWORK SYSTEM, PAINT AREA OF PANEL INSIDE THE OPENWORK SYSTEM
<br />TO MATCH FACTORY -COLORED PANELS.
<br />END OF SECTION 09 50 00
<br />SECTION 09 65 19
<br />RESILIENT TILE FLOORING
<br />V02212011
<br />1. GENERAL:
<br />1.1. THIS SECTION ALSO CONTAINS INFORMATION NORMALLY FOUND IN SECTION 09 65
<br />13 RESILIENT
<br />BASE & ACCESSORIES.
<br />1.2. SUBMITTALS:
<br />1.2.1 SUBMIT L01 IN ACCORDANCE WITH SECTION 01 33 00 SUBMITTAL PROCEDURES.
<br />2. PRODUCTS:
<br />2.1. VINYL COMPOSITION TILE (VCT): MANUFACTURER, SERIES, AND COLOR AS INDICATED
<br />ON
<br />DRAWINGS.
<br />2.2. VINYL TREADS AND RISERS: ROPPE TILE. SEE DRAWINGS FOR COLOR AND SERIES.
<br />2.3. VINYL BASE:
<br />2.3.1 WALLS: PROVIDE 6" X 1/8" GAUGE, LONG TOE WALL BASE, WITH ALL
<br />OUTSIDE CORNERS PREFORMED. LONG TOE SHOULD BE AT LEAST 122.
<br />2.3.2 CABINET BASE: PROVIDE 4" X 1/8" GAUGE COVED BASE, WITH ALL
<br />OUTSIDE CORNERS PREFORMED.
<br />2.3.3 ADHESIVE: MANUFACTURER'S WALL BASE ADHESIVE.
<br />2.3.4 ACCEPTABLE MANUFACTURERS: ARMSTRONG
<br />BURKE FLOORING PRODUCTS
<br />FLEXCO JOHNSONITE MACKLANBURG-DUNCAN
<br />MANNINGTON
<br />2.4. REDUCER STRIPS: 4" VINYL STRAIGHT BASE, COLOR TO MATCH PRIMARY COLOR OF
<br />ADJACENT VCT.
<br />2.5. EPDXY ADHESIVE: ARMSTRONG S-230 TWO-PART EPDXY OR EQUAL AS
<br />RECOMMENDED BY TILE MANUFACTURER AND APPROVED BY PUBLIX.
<br />2.6. ALL OTHER APPLICATIONS: MAPEI G19 LOW VOC URETHANE OR EQUAL AS
<br />RECOMMENDED BY TILE MANUFACTURER AND APPROVED BY PUBLIX.
<br />2.7. ACCESSORIES AND MISCELLANEOUS ITEMS: PROVIDE ALL ACCESSORY ITEMS
<br />REQUIRED FOR A COMPLETE INSTALLATION.
<br />{
<br />,'I -'I,
<br />a�
<br />N
<br />O
<br />--I
<br />.t�N
<br />(= e 0
<br />00
<br />U
<br />U M
<br />CT aN
<br />Ua
<br />#
<br />d
<br />"IZ
<br />1 1
<br />li
<br />o
<br />� �
<br />O ,
<br />Z `o
<br />•
<br />U
<br />��I�as
<br />o
<br />•,
<br />kn
<br />0 0
<br />tt
<br />N _
<br />b
<br />1.0aw1w
<br />IV rA
<br />QI CL
<br />J
<br />W
<br />g
<br />'P.4 R
<br />b4
<br />wo
<br />0
<br />rA Z
<br />5g
<br />� O
<br />rn
<br />0
<br />04
<br />QN
<br />z W M
<br />m Z H C4
<br />w rn
<br />U W J v
<br />IrIr U) O
<br />O O
<br />U W
<br />w
<br />0
<br />U
<br />a
<br />VJ
<br />W
<br />e
<br />w
<br />c< Q
<br />NG
<br />Of <
<br />d
<br />L.LjW Fw-
<br />O M
<br />rr�� m V_
<br />00
<br />VJ O M
<br />��// M
<br />x V LLX
<br />mz
<br />z �aY
<br />0
<br />z Q_ cM
<br />w
<br />J
<br />U
<br />1 Lo
<br />2 IT-
<br />8 4t
<br />s
<br />F. W
<br />g Z
<br />a.
<br />AS O
<br />U
<br />G
<br />is
<br />0
<br />U
<br />1
<br />N
<br />j >_
<br />le C)
<br />Is Is Z 11'
<br />9 0- ---r
<br />u7
<br />I
<br />M LU
<br />I N o
<br />a Ix
<br />9 O
<br />i p tJi.
<br />L
<br />J C%
<br />w m J
<br />F z J J 2
<br />W ��=
<br />z -' ZD 00 d
<br />g
<br />a P_N
<br />P.
<br />i lrl�_ �_
<br />...
<br />•
<br />Q`O�•a?��.,
<br />E
<br />8
<br />>
<br />w (,p
<br />%'
<br />w
<br />W) in
<br />i W
<br />= rn
<br />oa
<br />$
<br />G
<br />IL
<br />a
<br />'
<br />m:'
<br />�
<br />RAG
<br />0
<br />2
<br />0
<br />U
<br />m
<br />N
<br />J
<br />N
<br />_l
<br />r_
<br />m
<br />m
<br />w
<br />Z)
<br />m
<br />u�
<br />o
<br />J
<br />w
<br />g
<br />rn
<br />z
<br />CM
<br />Z,
<br />00
<br />U
<br />ono
<br />N
<br />w
<br />m
<br />z
<br />N
<br />LLJ
<br />CD
<br />U
<br />~
<br />O
<br />H
<br />w
<br />�
<br />a
<br />U
<br />__ : -
<br />R I��
<br />AUG 2019
<br />_s Construction, Inc.
<br />
|