Laserfiche WebLink
1. DATA CABLING SHALL BE PLENUM RATED <br />CATEGORY 6 EQUAL TO BELDEN #3612. COLOR PER <br />OWNERS REQUIREMENTS. <br />2. CABLING SHALL BE TERMINATED IN THE <br />ASSOCIATED SERVICE BRANCHES STORAGE ROOM <br />ON A WALL MOUNTED 48 PORT PATCH PANEL. <br />3. LABELING PER OWNERS REQUIREMENTS. <br />4. FACEPLATES SHALL BE WHITE THERMOPLASTIC <br />WITH ID LABELS. <br />2 PORT <br />U <br />O[TELECOMMUNICATION FACEPLATE DETAIL <br />r <br />RECEPTACLE. LEVITON <br />IEL #6898-1 WITH LED <br />:ATOR LIGHT OR EQUAL. <br />RAINTIGHT WHILE IN -USE <br />ENCLOSURE. LEVITON MODEL <br />#5997-CL OR EQUAL. <br />O � WEATHERPROOF RECEPTACLE DETAIL � <br />-1 <br />5 <br />GROUND PAD ASSEMBLY <br />BOND TO BUILDING GROUND <br />PRESSURE RING -T <br />SI RUC] UKE <br />NOTES: <br />1. USE WATERTIGHT CONDUIT SEAL WHERE CONDUIT <br />PENETRATIONS OF BUILDING EXTERIOR WALLS ARE <br />BELOW GRADE AND FOR TUNNEL PENETRATIONS. <br />2. ADJUSTABLE GLAND LOCATED WHERE ACCESSIBLE. <br />BODY CONCRETE <br />WALL <br />=RSIZE <br />EVE <br />gDUIT <br />OF <br />SIRUCIURE <br />Q ONDUIT PENETRATION DETAIL � <br />ELECTRICAL MAIN GROUND BUS <br />FROM SERVICE GROUND (NOTE #1) <br />BUILDING STEEL <br />(NOTE #1) <br />EMGB <br />WATER SERVICE <br />VALVES <br />WM <br />(NOTE #1) <br />CADWELD, TYPICAL. <br />REBAR, OR AS REQUIRED ROUND CLAMPS, <br />PER NEC 250. ACROSS WATER METER. <br />GROUND JUMPER <br />�o (NOTE #1) <br />y0 _1 <br />NOTE #1) <br />(NOTE #1) <br />10'-0" <br />"X10'-O" COPPERWELD <br />)UND ROD (TYPICAL) <br />NOTES: <br />1. WIRING SHALL CONSIST OF: 1#1/OG, 1"C. <br />2. LOCATE GROUND RODS IN ANY ARRANGEMENT TO AVOID <br />OBSTRUCTIONS, BUT MAINTAIN 25'-0" MINIMUM SEPARATION AND <br />MEET APPROVAL OF OWNER. <br />3. TAKE EVERY POSSIBLE PRECAUTION TO AVOID UNDERGROUND <br />UTILITIES, REVIEW ALL AVAILABLE DRAWINGS AND CONTACT "DIG <br />SAFE", PRIOR TO CONSTRUCTION. <br />4. E.C. SHALL BE RESPONSIBLE TO ENSURE THAT GROUND RESISTANCE IS <br />LESS THAN OR EQUAL TO 10-OHMS. E.C. SHALL SUPPLEMENTAL <br />GROUNDING ELECTRODES AS NECESSARY TO ESTABLISH 10-OHMS <br />(MINIMUM) RESISTANCE TO GROUND. <br />5. GROUNDING & BONDING SHALL BE INSTALLED IN ACCORDANCE WITH <br />NEC (2017), ARTICLE 250. <br />O � GROUNDING GRID DETAIL � <br />CEILING MOUNTED <br />OCCUPANCY SENSOR CEILING MOUNTED <br />SMOKE DETECTOR <br />A/C j7 <br />SEE NOTE 7 DIFFUSER PROVIDE PENDANT <br />WHERE REQUIRED <br />71-6" EXIT EXIT SIGN <br />61811 <br />(MIN.) FIRE ALARM AUDIO/-- _ PANELBOARD <br />6'4" VISUAL DEVICE <br />-' <br />WALLTELEPHONES SEE NOTE 6 <br />l <br />4'-6" <br />I' <br />4'-0" u u <br />COUNTER; SEE NOTE 4 <br />11ral <br />3 -8 FIRE ALARM i ©i ®0 BACKSPLASH -- <br />SEE PULL STATION � _ <br />NOTE - =, <br />2'-3" 8 SWITCHES -_- <br />RECEPTACLE AREA OF CANE <br />DETECTION <br />i ,I liu <br />i <br />TELECOMMUNICATION <br />OUTLETS <br />j L FINISHED FLOOR <br />NOTES: <br />1. DEVICE LOCATIONS AND MOUNTING HEIGHTS SHALL BE CHECKED AGAINST THE ARCHITECTURAL PLANS AND <br />ELEVATIONS PRIOR TO ROUGH -IN IN ORDER TO AVOID INTERFACES WITH CASEWORK, FURNITURE, WINDOWS, <br />MIRRORS, EQUIPMENT, ETC. <br />2. LOCATIONS OF OUTLETS AND EQUIPMENT AS INDICATED ON THE DRAWINGS ARE APPROXIMATE. THE EXACT <br />CENTER OF ALL OUTLETS SHALL BE PLACED IN COOPERATION WITH THE GENERAL CONTRACTOR AND <br />ARCHITECT. CONTRACTOR SHALL EXAMINE ALLTHE EXTERIOR DETAILS OF THE CONSTRUCTION DRAWINGS FOR <br />OUTLET LOCATIONS NOT CONFORMING TO THE DETAIL ABOVE. WHERE DETAILED TO SPECIFIC LOCATIONS, THE <br />ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE. IF AN OUTLET IS INSTALLED IN SUCH A LOCATION AS TO <br />BE OUT OF PROPER RELATION TO BE CORRECTED BY AT THE EXPENSE OF THE CONTRACTOR UNDER THE <br />DIRECTION OF THE ARCHITECT OR ENGINEER. <br />3. DEVICES SHALL BE CENTERED IN A COMMON VERTICAL PLANE. HEIGHT SHALL BE MEASURED FROM FINISHED <br />FLOOR TO CENTERLINE OF DEVICE EXCEPT EXIT SIGNS, AND FIRE ALARM SIGNALS. COORDINATE LOCATIONS <br />WITH MATERIALS SUCH AS MASONRY UNITS. <br />4. REFER TO THE ARCHITECTS ELEVATION DETAILS FOR EXACT MOUNTING HEIGHT AND LENGTH OF SURFACE <br />RACEWAYS. RECEPTACLE MOUNTING HEIGHT ABOVE COUNTERS SHALL BE COORDINATED WITH CASEWORK <br />HEIGHTS. <br />5. PROTRUDING OBJECTS CANNOT REDUCE THE MINIMUM WIDTH OF ACCESSIBLE ROUTES. <br />6. 4" MAX PROTRUDING FROM WALL FOR CANE. <br />7. OBJECTS ABOVE HEAD ROOM CLEARANCE (MIN. OF 7'-6") CAN PROTRUDE ANY AMOUNT. <br />8. OBJECT WITH LEADING EDGES WITHIN CANE SWEEP CAN PROTRUDE ANY AMOUNT. <br />® TYPICAL DEVICE MOUNTING HEIGHTS DETAIL <br />ELECTRICAL CONTRACTOR SHALL PROVIDE <br />ENGRAVED COVERPLATES TO INDICATE <br />PANEL NAME AND CIRCUIT NUMBER. (TYP) <br />NOTE: <br />1. GENERAL RECEPTACLES AND COVERPLATES SHALL BE WHITE IN COLOR, UNLESS OTHERWISE INDICATED. <br />O � TYPICAL RECEPTACLE LABELING DETAIL I <br />ACCESSIBLE CEILING <br />TERMINATE WITH INSULATED <br />THROAT BUSHING. <br />- 1" EMT. <br />PROVIDE RANDL INDUSTRIES <br />OR EQUAL 5" SQUARE BOX, <br />2-7/8" DEEP W/ INTEGRAL <br />CABLE MANAGEMENT AND <br />SINGLE GANG RAISED COVER <br />NOTES: <br />1. COORDINATE ROUGH -IN REQUIREMENTS WITH OWNER'S <br />TELECOMMUNICATIONS VENDOR PRIOR TO START OF ANY WORK. <br />2. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS. <br />3. PROVIDE ACCESSIBLE PULL BOXES, SIZED PER TIA STANDARDS, AS NEEDED. <br />® TELECOMMUNICATIONS CONDUIT DETAIL <br />PROVIDE A FULL TIA <br />COMPLIANT RACEWAY <br />SYSTEM (TYP) <br />1" EMT TO 12" ABOVE <br />FINISHED SUSPENDED <br />CEILING. EMT SHALL <br />BE FULLY CONCEALED <br />IN FINISHED WALL. <br />FINISHED <br />WALL <br />STRUCTURAL OVERHEAD <br />I, <br />NO PIPING OR DUCTWORK SHALL <br />.. <br />BE INSTALLED WITHIN THE SPACE <br />_ <br />DIRECTLY ABOVE ELECTRICAL <br />PANELS OR SWITCHGEAR <br />\ / <br />ELECTRICAL PANEL <br />ELECTRICAL PANEL <br />WORKSPACE AS <br />DEFINED BY THE <br />WALL <br />NATIONAL ELECTRIC <br />CODE <br />/ \ <br />NO PIPING OR DUCTWORK SHALL <br />\ <br />, <br />BE INSTALLED WITHIN THE <br />ELECTRICAL PANEL WORKSPACE <br />FLOOR <br />O � ELECTRICAL/MECHANICAL EQUIPMENT COORDINATION <br />KEYED DETAIL NOTES: <br />�1 TO LOCAL UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA. CONCEAL ALL WIRING. <br />2� HARD WIRE TO JUNCTION BOX (DO NOT PLUG IN). <br />�3 BATTERY UNIT. SEE SPECIFICATIONS. SIZE UNIT TO HANDLE FULL LOAD FOR 1 1/2 <br />HOURS TO 87 1/2% OF VOLTAGE OR PROVIDE ADDITIONAL UNITS TO ACCOMPLISH <br />THIS. MOUNT SO THAT IT CAN BE READILY MAINTAINED AND TESTED. <br />O TO DEDICATED UNSWITCHED EXIT SIGN CIRCUIT. CONCEAL ALL WIRING. <br />® I EMERGENCY BATTERY SCHEMATIC <br />0 0 <br />PANELBOARD: <br />100A 208Y/120V 1/4" LETTERS (TYP) <br />FED FROM <br />0 0 <br />NOTES: <br />1. NAMEPLATES SHALL BE FURNISHED AND INSTALLED ON THE METER CENTERS/SWITCHBOARD AND METER <br />CENTERS/SWITCHBOARD CIRCUIT BREAKERS, PANELBOARDS, TRANSFORMERS, JUNCTION BOXES, CABINETS <br />FOR ALL SPECIAL PURPOSE SWITCHES, MOTOR DISCONNECT SWITCHES, STARTERS AND OTHER CONTROLS <br />FURNISHED UNDER THIS CONTRACT, TO DESIGNATE THE EQUIPMENT CONTROLLED AND FUNCTION. <br />2. NAMEPLATES SHALL BE LAMINATED WHITE BAKELITE WITH 1/4" HIGH BLACK RECESSED LETTERS. <br />3. NAMEPLATES SHALL BE SECURELY ATTACHED TO THE EQUIPMENT WITH GALVANIZED SCREWS OR RIVETS. <br />4. ADHESIVES OR CEMENTS WILL NOT BE PERMITTED. <br />10 TYPICAL PANELBOARD NAMEPLATE DETAIL <br />PROJECT: <br />PINCHASERS EAST PASCO <br />ANTHONY PERRONE <br />6816 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />PROJECT NUMBER: 21 161 <br />J Lo0 <br />O <br />o <br />cv U <br />o� <br />U <br />Lu QLU <br />u�< <br />�Q <br />06 <br />1:4o <br />Lu co <br />0 03 <br />M 10 <br />o v <br />w� <br />F L0 <br />_ ITV) <br />r n <br />IT <br />v I <br />,o <br />Lu <br />U wC <br />� <br />N <br />�N <br />z J^ <br />Z 1- <br />LPL <br />w <br />Lu L <br />CO <br />U o <br />(V L0 <br />Q < <br />11 ia <br />a� <br />¢� U <br />U <br />O'\ <br />ct <br />ono `(+�N-r) <br />• ^�, rn <br />M <br />M M `-' <br />V/ <br />N���kn� <br />O M <br />kn <br />1.�I • tf) <br />r. � <br />© Ooo00 pU <br />2 o <br />, <br />M <br />�V 00 <br />STAMP: <br />44010 I <br />N <br />L y <br />TAT F <br />ISSUE: <br />DATE: <br />ISSUED FOR PERMIT <br />01 /25/2023 <br />DRAWING SCALE: NOTED <br />DRAWN BY: SB <br />CHECKED BY: MD <br />DRAWING TITLE: <br />ELECTRICAL - DETAILS <br />DRAWING NUMBER: <br />3,o 0 <br />I- <br />off- �� - - �� I - - - - <br />,..: _TTTu1�h l l,l <br />� .I I_.. I i.- .. i,n ,�.�,�,. u. IiL. .i... �., I:.II. I-i. L. _il �_J.'..I J. � �� �T���� i i I (� i � I I. �.. � t� I .L. � I_ �. �.� �I <br />