Laserfiche WebLink
LIFE SAFETY PLAN LIFE SAFETY PLAN LEGEND <br />1 /8" = 1'-0" <br />HD 135 RATE OF RISE HEAT DETECTOR �O CARBON MONOXIDE DETECTOR EXIT SIGN <br />FD 200 FIXED HEAT DETECTOR <br />H S FIRE ANNUNCIATOR (HORN/STROBE) <br />S FIRE ANNUNCIATOR (MINI STROBE) <br />PS PULL STATION <br />D\) SMOKE DETECTOR (PHOTO ELECTRIC) <br />\_i <br />SO, SMOKE DETECTOR (IONIZING) <br />KEY SAFE (KNOX BOX) <br />FE FIRE EXTINGUISHER CABINET <br />EGRESS PATH <br />WALL MOUNTED EMERGENCY LIGHT FIXTURE <br />v <br />No I J �0' <br />CODE SUMMARY <br />PINCHASERS <br />6816 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />AREA INCLUDED WITHIN SCOPE IS A RENOVATION OF 29,000 SF OF AN EXISTING ASSEMBLY <br />A-2 (RESTAURANT) AND A-3 (BOWLING ALLEY AND AMUSEMENT ARCADES) IN A SINGLE STORY <br />TYPE 2B BUILDING. <br />101.5 COMPLIANCE METHODS (CODES USED FOR ANALYSIS): <br />7T" EDITION OF THE FLORIDA BUILDING CODE: <br />2020 FLORIDA BUILDING CODE, BUILDING (2018 IBC) <br />2020 FLORIDA BUILDING CODE, EXISTING BULDING (2018 IEBC) <br />2020 FLORIDA BUILDING CODE, PLUMBING <br />2020 FLORIDA BUILDING CODE <br />301.1.3.2 WORK AREA COMPLIANCE METHOD <br />ALTERATIONS, ADDITIONA AND CHANGES OF OCCUPANCY COMPLYING WITH THE <br />APPLICABLE REQUIREMENTS OF CHAPTER 6 THROUGH 12 OF THIS CODE SHALL BE <br />CONSIDERED IN COMPLIANCE WITH THE PROVISION OF THIS CODE. <br />2018- INTERNATIONAL EXISTING BUILDING CODE WITH FLORIDA AMENDMENTS <br />CHPATER 6 - CLASSIFICATION OF WORK <br />603.1 - LEVEL 2 ALTERATIONS INCLUDE RECONFIGURATION OF SPACE, THE ADDITION OR <br />ELIMINATION OF ANY DOOR OR WINDOW, HE RECONFIGURATION OR EXTENSION OF ANY <br />SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. <br />CHAPTER 7-8 - ALTERATIONS LEVEL 2 <br />701.2 CONFORMANCE - AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE <br />ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN IT'S EXISTING CONDITION. <br />COMPLIES <br />702.1 (-) 702.3 BUILDING ELEMENTS AND MATERIALS -ALL NEW FINISHES SHALL COMPLY <br />WITH CHAPTER 8 OF THE IBC - COMPLIES <br />704.1 MEANS OF EGRESS: <br />ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF PROTECTION <br />PROVIDED FOR THE MEANS OF EGRESS <br />COMPLIES <br />801.3 - COMPLIANCE <br />ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY <br />I WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. - COMPLIES <br />803.2 - AUTOMATIC SPRINKLER SYSTEMS <br />AUTOMATIC SPRINKLER SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF SECTIONS 804.2.1 THROUGH 804.2.5. INSTALLATION REQUIREMENTS <br />SHALL BE IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. <br />IBC 903.2.1.2 SPRINKLER SYSTEM SUPERVISION & ALARMS <br />AUTOMATIC SPRINKLER SYSTEM IS REQUIRED > 5,000 SF OR 100+ OCCUPANTS <br />COMPLIES - SPRINKLER SYSTEM IS INSTALLED <br />803.4 FIRE ALARM AND DETECTION <br />A FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH <br />SECTIONS 804.4.1.1 THROUGH 804.4.1.7. EXISTING ALARM -NOTIFICATION APPLIANCES <br />SHALL BE AUTOMATICALLY ACTIVATED THROUGHOUT THE BUILDING. WHERE THE BUILDING <br />IS NOT EQUIPPED WITH A FIRE ALARM SYSTEM, ALARM -NOTIFICATION APPLIANCES WITHIN <br />THE WORKAREA SHALL BE PROVIDED AND AUTOMATICALLY ACTIVATED. - COMPLIES <br />805.3.1 NUMBER OF EXITS <br />EVERY STORY UTILIZED FOR HUMAN OCCUPANCY ON WHICH THERE IS A WORK AREA THAT <br />INCLUDES EXITS OR CORRIDORS SHARED BY MORE THAN ONE TENANT WITHIN THE WORK <br />AREA SHALL BE PROVIDED WITH THE MINIMUM NUMBER OF EXITS BASED ON THE <br />OCCUPANCY AND THE OCCUPANT LOAD IN ACCORDANCE WITH THE INTERNATIONAL <br />BUILDING CODE. IN ADDITION, THE EXITS SHALL COMPLY WITH SECTIONS 805.3.1.1 <br />AND 805.3.1.2. - COMPLIES <br />805.3.3 MAIN ENTRANCE - GROUP A <br />BUILDINGS OF GROUP A WITH AN OCCUPANT LOAD OF 300 OR MORE SHALL BE PROVIDED <br />WITH A MAIN ENTRANCE CAPABLE OF SERVING AS THE MAIN EXIT WITH AN EGRESS CAPACITY <br />OF NOT LESS THAN ONE-HALF OF THE TOTAL OCCUPANT LOAD. THE REMAINING EXITS <br />SHALL BE CAPABLE OF PROVIDING ONE-HALF OF THE TOTAL REQUIRED EXIT CAPACITY. <br />TOTAL OCCUPANTS :330; MAIN ENTRANCE - 69" = 13.8" <br />805.4.1.1 OCCUPANT LOAD AND TRAVEL DISTANCE <br />IN ANY WORK AREA, ALL ROOMS AND SPACES HAVING AN OCCUPANT LOAD GREATER THAN <br />50 OR IN WHICH THE TRAVEL DISTANCE TO AN EXIT EXCEEDS 75 FEET (22 860 MM) SHALL <br />HAVE A MINIMUM OF TWO EGRESS DOORWAYS. <br />EXCEPTIONS: <br />l . STORAGE ROOMS HAVING A MAXIMUM OCCUPANT LOAD OF 10. <br />2. WHERE THE WORK AREA IS SERVED BY A SINGLE EXIT IN ACCORDANCE <br />WITH SECTION 805.3.1.1 . SEE LIFE SAFETY PLAN - COMPLIES <br />805.7.1 - MEANS OF EGRESS LIGHTING <br />MEANS OF EGRESS IN ALL WORK AREAS SHALL BE PROVIDED WITH ARTIFICIAL LIGHTING IN <br />ACCORDANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. - <br />COMPLIES <br />805.8.1 - EXIT SIGNS <br />WHERE THE WORK AREA ON ANY FLOOR EXCEEDS 50 PERCENT OF THAT FLOOR AREA, <br />MEANS OF EGRESS THROUGHOUT THE FLOOR SHALL COMPLY WITH SECTION 805.8.1. - <br />COMPLIES - SEE ELECT. DWGS. <br />2018 IBC WITH AMENDMENT <br />302.1 CLASSIFICATION <br />USE GROUP: <br />303.1 A-2 -ASSEMBLY GROUP (ACCESSORY USE) <br />TABLE 601 FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS <br />CONSTRUCTION TYPE 2B <br />PRIMARY STRUCTURAL FRAME: 0 HOUR <br />BEARING WALLS EXTERIOR: 0 HOUR <br />BEARING WALLS INTERIOR: 0 HOUR <br />EXTERIOR NON -BEARING: 0 HOUR <br />INTERIOR NON -BEARING: 0 HOUR <br />ROOF CONSTRUCTION: 0 HOUR <br />TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT <br />GAMING FLOORS 11 GROSS SF PER OCCUPANT <br />ASSEMBLY; UNCONCENTRATED 15 NET SF PER OCCUPANT <br />ACCESSORY STORAGE 300 GROSS SF PER OCCUPANT <br />COMMERCIAL KITCHEN 200 GROSS SF PER OCCUPANT <br />MERCANTILE 60 GROSS SF PER OCCUPANT <br />BOWLING CENTERS 5 PERSONS/ LANE AND 15' OF RUNWAY <br />AND 7 NET SF PER OCCUPANT <br />FOR ADD'L. <br />ARCADE: 1,391 SF/ 11 = 126 OCCUPANTS <br />BOWLING LANES: 32 LANES x 5 = 160 OCCUPANTS <br />RESTAURANT; 937 SF/ 15= 63 OCCUPANTS <br />COMMERCIAL KITCHEN & BAR: 855 SF/ 200 = 5 OCCUPANTS <br />BAR SEATING: 25 SEATS <br />MERCATILE (PRO SHOP) = 291 SF/ 60 = 5 OCCUPANTS <br />STORAGE: 2,566 SF/ 300 = 9 OCCUPANTS <br />TOTAL = 330 OCCUPANTS <br />1005.1 MINIMUM REQUIRED EGRESS WIDTH <br />EGRESS COMPONENTS: 0.2 X 330 OCCUPANTS= 66" WIDTH <br />TOTAL DOOR WIDTH - 129" PROVIDED <br />COMPLIES <br />TABLE 1006.2.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY <br />EXTERIOR EXITS: 2 REQUIRED ACTUAL: 3 <br />COMPLIES <br />MAXIMUM COMMON PATH OF TRAVEL < 75' <br />PROJECT: <br />PINCHASERS <br />ANTHONY PERRONE <br />6816 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />PROJECT NUMBER: 21161 <br />STAMP: <br />r ^ L 12 <br />i cO <br />v J CD U <br />CV <br />C) u <br />�, w <br />LLJ D- <br />2 <br />U U <br />�J Ofo W m <br />O X <br />0 <br />1 c \�- <br />10 <br />CN <br />CN IT <br />^ Ln <br />Ln <br />v7 06 <br />z Wo <br />U w <br />H � <br />z <br />c/7 CCN <br />V <br />LLJ � N <br />Q Z � <br />w CV <br />U C6 <br />CV CD <br />C'7 Ln <br />CL <br />/100 <br />alai' <br />OF <br />FLO'Qi <br />G? MC0LWF�`'9 <br />p AR 99449 V <br />�SA . kA <br />ISSUE: DATE: <br />ISSUED FOR PERMIT 01.25.2023 <br />DRAWING SCALE: As indicated <br />DRAWN BY: CHECKED BY: Checker <br />DRAWING TITLE: <br />CODE ANALYSIS PLAN <br />SHEET NUMBER: <br />Glol <br />I. <br />