Laserfiche WebLink
B1-2 <br />O O <br />J U <br />O B2-2 <br />B2 -4 <br />1 Electrical Power Plan <br />Scale 1/8"=1'-0" <br />Power Plan Key Notes: <br />1O EXISTING J-BOX AND EMPTY 314" CONDUIT. EXTEND <br />CONDUIT AS NEEDED AND RUN NEW WIRES TO NEW <br />TENANT PANEL VIA TIME CLOCK. <br />O EXISTING RTU TO BE WIRED BACK TO NEW TENANT PANEL. <br />CONTRACTOR SHALL VERIFY THAT THERE IS AN EXISTING <br />SMOKE DUCT DETECTOR IN THE SUPPLY DUCT. IF THERE <br />ISN'T, REFER TO MECHANICAL GENERAL NOTE # 7 ON <br />SHEET M101. THE GC SHALL BE RESPONSIBLE FOR <br />COORDINATING THE EXACT SCOPE OF WORK REQUIRED <br />BETWEEN THE MECHANICAL SUB AND THE ELECTRICAL <br />SUB PRIOR TO BIDDING. NO CHANGE ORDERS WILL BE <br />APPROVED FOR FAILURE TO VERIFY EXISTING <br />CONDITIONS OR COORDINATE BETWEEN SUBS. <br />SO EXISTING FACTORY INSTALLED DISCONNECTS. FOR <br />POWER REQUIREMENTS TO RTU'S, RE: M101 AND <br />ELECTRICAL PANEL SCHEDULE ON THIS SHEET. <br />O EXISTING FACTORY INSTALLED POWERED CONVENIENCE <br />OUTLET. INSTALLATION SHALL BE PER SECTION 210.63 OF <br />THE NEC. COORDINATE WITH MECHANICAL. <br />�5 EXISTING LOCATIONS OF TELEPHONE CONDUIT STUB -INS <br />TO BE RELOCATED. <br />O6 NEW TELEPHONE CONDUIT STUB IN LOCATION. NO <br />TELEPHONE TERMINAL BOARD OR RECEPTACLE ADDED. <br />THE TENANT SHALL BE RESPONSIBLE FOR PULLING THE <br />COMMUNICATION CABLE FROM THE EXISTING TELEPHONE <br />TERMINAL CABINET TO THE SPACE AND FOR PROVIDING <br />THE TELEPHONE TERMINAL BOARD AS PART OF THE <br />FUTURE TENANT WORK. <br />7O EXISTING LOCATIONS OF ELECTRICAL CONDUIT STUB -INS <br />TO BE RELOCATED. <br />O NEW 225 AMP TENANT ELECTRICAL PANEL SURFACE <br />MOUNTED OVER FIRE RATED WALL. REFER TO PANEL <br />SCHEDULES AND RISER DIAGRAM ON E301. <br />11 <br />A <br />B2-5 <br />EF <br />a� <br />A <br />B1-3= <br />EM <br />11 v 'IN 131 -1 <br />\— <br />EXISTING EM <br />FIXTURE TO <br />BE REWIRED <br />12 <br />C 0- <br />EM < <br />EXISTING EM <br />FIXTURE TO <br />BE REWIRED <br />EXISTING X B1-1 <br />FIXTURE TO <br />BE REWIRED <br />X <br />X <br />EXISTING X 7771 <br />FIXTURE TO BE B2 -1 <br />RELOCATED <br />AND REWIRED <br />THE REMAINDER OF THE <br />LIGHTING IN THE SPACE <br />SHALL BE PROVIDED AS <br />PART OF THE FUTURE <br />TENANT BUILD OUT <br />2 Electrical Lighting Plan <br />Scale <br />Lighting Plan Key Notes: <br />11 EXISTING DECORATIVE SCONCE FIXTURES SHALL REMAIN <br />WIRED AS IS TO THE EXISTING HOUSE PANEL. <br />12 EXISTING REAR WALL MOUNTED LIGHT SHALL BE WIRED <br />TO THE NEW TENANT PANEL VIA NEW LIGHT SWITCH. <br />EXISTING EM <br />FIXTURE TO <br />BE REWIRED <br />EM <br />B2-3 <br />Lighting General Notes: <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. VERIFY FIXTURE LOCATION, SEE REFLECTED CEILING PLAN. <br />3. MOUNTING HEIGHTS INDICATED ARE TO THE CENTER LINE OF <br />DEVICE OR FIXTURE UNLESS OTHERWISE NOTED. <br />4. RESTROOM FIXTURES TO BE CENTERED IN ROOMS. <br />5. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & <br />INSTALLED BY ELECTRICAL. CONTRACTOR, <br />6. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL <br />SPARE OF ALL LAMP TYPES TO BE LEFT AT JOB SITE AT END <br />OF JOB. <br />7. CIRCUIT BREAKERS USED AS SWITCHES IN 120V AND 277V <br />FLUORESCENT LIGHTING CIRCUITS SHALL BE LISTED AND <br />SHALL BE MARKED SWD OR HID. <br />Light Fixture Schedule <br />TYPE <br />MANUFACTURER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING & OPTION <br />NOTE <br />A <br />DAYBRITE <br />2TG8-3-32-01-UNV-1/3-EB <br />120 <br />(3) 32W T8 <br />FLUSH MOUNTED <br />1-3,5-6 <br />C <br />NITE BRITES <br />WCR-050-M-MT <br />120 <br />- <br />EXISTING TO REMAIN <br />EM <br />BEGHELLI <br />XLP-Si <br />120 <br />- <br />WALL MTD AT 9'-WAFF <br />2 & 4 <br />X <br />BEGHELLI <br />VA4-R-SA <br />120 <br />LED (INCLUDED) <br />UNIVERSAL <br />2 & 4 <br />ALTERNATE FIXTURES MAY BE COOPER, LITHONIA, GENLYTE, HUBBELL, OR THOMAS. FIXTURE <br />SUBSTITUTIONS MUST BE APPROVED BY OWNER BEFORE THEY ARE SUBMITTED TO THE ENGINEER. <br />1. ALL FLUORESCENT LIGHTING FIXTURES SHALL 4. <br />ALL EMERGENCY, EXIT AND NIGHT LIGHT FIXTURES <br />HAVE ENERGY SAVING LAMPS AND ELECTRONIC <br />SHALL BE CONNECTED AHEAD OF LOCAL SWITCHES. <br />BALLASTS. <br />UNLESS OTHERWISE NOTED. <br />2. PROVIDE NECESSARY MOUNTING HARDWARE 5. <br />ALL ALTERNATE FIXTURES SHALL BE SUBMITTED <br />AND ACCESSORIES FOR ALL FIXTURES. <br />FOR PRIOR APPROVAL, SEE SPECIFICATIONS. <br />3. PROVIDE .125 MIN. THICK LENSES FOR 6. <br />CONTACT SESCO LIGHTING (407) 629-6100 DAN <br />FLUORESCENT FIXTURES. <br />SCHULMAN <br />3 Fire Alarm Plan <br />Scale <br />Fire Alarm Notes: <br />ALL FIRE ALARM EQUIPMENT IS SHOWN FOR REFERENCE <br />$ <br />PURPOSES ONLY. FIRE ALARM DESIGN DRAWINGS SHALL <br />° <br />BE SUBMITTED BY TENANT BUILD OUT CONTRACTOR, <br />SIGNED AND SEALED BY STATE OF FLORIDA LICENSED AND <br />a <br />REGISTERED ENGINEER. <br />U <br />U <br />U <br />C <br />N <br />C <br />O <br />CL <br />0 <br />rL.� <br />�/ LLI <br />CZ <br />`R 00 <br />v � <br />VaM <br />CV) <br />■�oU- <br />w Ema <br />� 'Lco <br />NG <br />J <br />U <br />CD <br />C <br />0 <br />E <br />E <br />O <br />U <br />L <br />i <br />0 <br />(U J <br />m <br />CN <br />m Q <br />C J <br />V m <br />& U- <br />Cn <br />w <br />CU <br />�Na <br />ti N <br />a <br />Cn <br />_ICU <br />a_ <br />CU <br />U <br />J V <br />w W <br />w <br />x <br />Cn <br />a a� <br />WE <br />c1,4 :D <br />Co ui at <br />*-+ g W <br />> w-i <br />o 0 <br />w <br />w <br />o� <br />u� <br />o <br />uv�} <br />N <br />J <br />W <br />d' <br />�I <br />O <br />Z rn <br />U <br />4 <br />O <br />�2 <br />N <br />Q <br />VJ <br />. <br />L) <br />a. <br />C <br />E101 <br />